Wide-band Models from DC to 100 MHz
|
|
- Tobias Day
- 5 years ago
- Views:
Transcription
1 CLAMP ON PROBE 327 series AC/DC CURRENT SENSOR CT686 series 99 Washington Street Melrose, MA 2176 Phone Toll Free Visit us at Wide-band Models from DC to MHz CLAMP ON PROBE 3276
2 2 CLAMP ON PROBE to 3276 Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due to breaks in the electrical path. The CLAMP ON PROBEs only need to be connected directly into the BNC input on waveform observation equipment such as an oscilloscope or a recorder. Then simply clamp onto the conductor to be measured to easily observe current waveforms under a wide bandwidth and high sensitivity conditions. Important Characteristics Square wave response DC to 5 MHz Transient response Low-current measurement Input: 1 khz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) 1. Frequency response Amplitude [db, db=1v] Input: 1 MHz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) Input: map-p (Oscilloscope bandwidth 4 MHz) 2. Continuous maximum input rating (Frequency derating) Maximum input current [Arms] 1k 1k k 1M 1M M Input: 1 khz sine wave 1 map-p 3. Input impedance Input impedance [Ω] 3276 DC to MHz 3276 Square wave response Transient response Low-current measurement Input: 1 khz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) Input: 1 MHz square wave 2 map-p (Oscilloscope bandwidth 4 MHz) Input: map-p (Oscilloscope bandwidth 4 MHz) Input: 1 khz sine wave 1 map-p 1. Frequency response 2. Continuous maximum input rating (Frequency derating) 3. Input impedance Amplitude [db, db=1v] Maximum input current [Arms] k 1k k 1M 1M M Input impedance [Ω]
3 CLAMP ON PROBE to High S/N ratio: ideal for measuring milliampere waveforms (Model ) Capable of waveform monitoring from wide band and minute currents to large currents (Model 3274) Permits waveform observation of large current of up to 5 Arms (Model 3275) Wide-band waveform observations, from DC to MHz (Model 3276) Direct connection to BNC input of oscilloscope Highly accurate current detection Newly developed indium-antimony (InSb) thin-film Hall element Simple overload protector prevents damage due to overheating Easy measurement Features The includes a soft case, the 3274 / 3275 /3276 includes a hard carrying case Waveform Example Automobile Starter Current A/div 1 s/div Lighting Inverter 2 ma/div 2 μs/div Press Machine Load Current 5 A/div 1 ms/div 3274 DC to 1 MHz 3274 Square wave response Transient response Low-current measurement Input: Hz square wave 2 Ap-p (Oscilloscope bandwidth MHz) 1. Frequency response Input: khz square wave 4 map-p (Oscilloscope bandwidth MHz) Input: 1 Ap-p (Oscilloscope bandwidth MHz) 2. Continuous maximum input rating (Frequency Derating) Input: 1 khz sine wave 5 map-p (Oscilloscope bandwidth MHz) 3. Input impedance Amplitude [db, db=1v] 3275 Square wave response Transient response Low-current measurement Input: Hz square wave 3 Ap-p Input: 1 khz square wave 4 map-p Input: 1 Ap-p Input: 1 khz sine wave 5 map-p 1. Frequency response 2. Continuous maximum input rating (Frequency Derating) 3. Input impedance Amplitude [db, db=1v] Maximum input current [Arms] Input impedance [Ω] Maximum input current [Arms] Input impedance [Ω] 1 m 1m 1m DC to 2 MHz 3275
4 4 CLAMP ON PROBE to / 3276 Specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months) Frequency bandwidth DC to 5 MHz (-3 db) * See Fig. 1 on page 1. Rise time Continuous maximum input range Maximum peak current value Output voltage rate 7 ns or less 3 Arms * Frequency derating see Fig. 2 on page 1. Non-continuous 5 Apeak.1 V/A Amplitude accuracy ±1.% rdg. ±1 mv ( to 3 Arms / DC, 45 to 66 Hz) ±2.% rdg. (3 Arms to 5 Apeak / DC, 45 to 66 Hz) Noise 2.5 marms or less (measured with 2 MHz bandwidth equipment) Input impedance * See Fig. 3 on page 1. Sensitivity temperature Maximum rated power Operating temperature and humidity Storage temperature and humidity Effect of external magnetic fields Within ±2% (At 5 Hz/3 Arms input, to 4 C [32 to 14 F]) 5.6 VA (Input within the maximum input range.) Power supply voltage ±12 V ±.5 V to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 2 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) Max. rated voltage to earth 3 V, CAT-I (insulated conductor) Measurement conductor Diameter max. 5 mm [.2"] Sensor: approx. 175(W) 18(H) 4(D) mm; 23 g Dimensions and mass [6.89"(W).71"(H) 1.57"(D), 8.1 oz.] Termination unit: approx. 27(W) 55(H) 18(D) mm [1.6"(W) 2.17"(H).71"(D)] Cable length Sensor cable: approx. 1.5 m [59.6"] (BNC connector) Power cable: approx. 1 m [39.37"] Supplied accessories Soft case 1 Applicable standards Safety standards EMC EN 611 Measurement category I (anticipated transient overvoltage 15 V), Pollution Degree 2 EN EN EN DC to MHz (-3 db) * See Fig. 1 on page ns or less 3 Arms * Frequency derating see Fig. 2 on page 1. Non-continuous 5 Apeak.1 V/A ±1.% rdg. ±1 mv ( to 3 Arms / DC, 45 to 66 Hz) ±2.% rdg. (3 Arms to 5 Apeak / DC, 45 to 66 Hz) 2.5 marms or less (measured with 2 MHz bandwidth equipment) * See Fig. 3 on page 1. Within ±2% (from to 4 C [32 to 14 F] ) 5.3 VA (Input within the maximum input range.) ±12 V ±.5 V to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 5 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) 3 V, CAT-I (insulated conductor) Diameter max. 5 mm [.2"] Sensor: approx. 175(W) 18(H) 4(D) mm; 24 g [6.89"(W).71"(H) 1.57"(D), 8.5 oz.] Termination unit: approx. 27(W) 55(H) 18(D) mm [1.6"(W) 2.17"(H).71"(D)] Sensor cable: approx. 1.5 m [59.6"] (BNC connector) Power cable: approx. 1 m [39.38"] Hard case 1 EN 611 Measurement category I (anticipated transient overvoltage 15 V), Pollution Degree 2 EN EN EN Sensor head Composed of molded parts, ferrite and Hall elements. The thin-film of the Hall element especially improves detection sensitivity to realize wider bands and high sensitivity monitoring /3276 : approx. 175(W) 18(H) 4(D) mm, [6.89"(W).71"(H) 1.57"(D)] Maximum measurement conductor: dia. 5 mm [.2"] Sensor cable (approx. 1.5 m [59.6"]) Power cable (approx. 1 m [39.37"]) Power supply plug Connects to the FET probe power supply outlet of an oscilloscope or to the optional 3269 / 3272 power supply unit. (Provided that connector type, pin assignment, voltage, and capacity rating match, the to 3276 can be powered also from another source. For operation safety, be sure to refer to the specifications to ensure an exact match.) Power supply plug pin assignment (Plug as seen from the front) 1 : Not connected : GND : V- (-12V) 4 : V+ (+12V) * Connector type: LEMO inc./ FFA.S.34.CLAC42Z Sensor cable (approx. 2 m [78.74"]) 3274/3275 : approx. 176(W) 69(H) 27(D) mm, [6.93"(W) 2.72"(H) 1.6"(D)] BNC output connector Can be connected directly to the BNC input of an oscilloscope or level recorder or similar device. Output voltage rate:.1 V/A ( / 3276).1 V/A (3274 / 3275) (Use only equipment with an input impedance of 1 MΩ or more.) Maximum measurement conductor: dia. 2 mm [.79"]
5 CLAMP ON PROBE to / 3275 Specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months) Frequency bandwidth DC to 1 MHz (-3 db) * See Fig. 1 on page 2. DC to 2 MHz (-3 db) * See Fig. 1 on page 2. Rise time 35 ns or less 175 ns or less Continuous maximum input range Maximum peak current value 15 Arms * Frequency derating see Fig. 2 on page 2. Non-continuous 3 Apeak 5 A peak at pulse width of 3 ms 5 Arms * Frequency derating see Fig. 2 on page 2. Non-continuous 7 Apeak Output voltage rate.1 V/A.1 V/A Amplitude accuracy Noise ±1.% rdg. ±1 mv ( to 15 Arms / DC, 45 to 66 Hz) ±2.% rdg. (15 Arms to 3 Apeak / DC, 45 to 66 Hz) ±1.% rdg. ±5 mv ( to 5 Arms / DC, 45 to 66 Hz) ±2.% rdg. (5 Arms to 7 Apeak / DC, 45 to 66 Hz) Input impedance * See Fig. 3 on page 2. * See Fig. 3 on page 2. Sensitivity temperature Within ±2% (At 55 Hz/15 A input, to 4 C [32 to 14 F]) Within ±2% (At 5 Hz/5 A input, to 4 C [32 to 14 F]) Maximum rated power 5.5 VA (Input within the maximum input range.) 7.2 VA (Input within the maximum input range.) Power supply voltage ±12 V ±1 V ±12 V ±.5 V Operating temperature and humidity Storage temperature and humidity Effect of external magnetic fields to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 15 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) to 4 C [32 to 14 F], 8% rh or less -1 to 5 C [14 to 122 F], 8% rh or less Max. 8 ma (equivalent) (DC and 6 Hz, Magnetic field of 4 A/m) Max. rated voltage to earth 6 V CAT-II, 3 V CAT-III (insulated conductor) 6 V CAT-II, 3 V CAT-III (insulated conductor) Measurement conductor Diameter max. 2 mm [.79"] Diameter max. 2 mm [.79"] Sensor: approx. 176(W) 69(H) 27(D) mm; 5 g Sensor: approx. 176(W) 69(H) 27(D) mm; 52 g Dimensions and mass [6.93"(W) 2.72"(H) 1.6"(D), 17.6 oz.] [6.93"(W) 2.72"(H) 1.6"(D), 18.3 oz.] Termination unit: approx. 27(W) 55(H) 18(D) mm Termination unit: approx. 27(W) 55(H) 18(D) mm [1.6"(W) 2.17"(H).71"(D)] [1.6"(W) 2.17"(H).71"(D)] Cable length Sensor cable: approx. 2 m [78.74"] (BNC connector) Sensor cable: approx. 2 m [78.74"] (BNC connector) Power cable: approx. 1 m [39.37"] Power cable: approx. 1 m [39.37"] Supplied accessories Hard case 1 Hard case 1 Applicable standards Safety standards EMC 25 marms or less (measured with 2 MHz bandwidth equipment) EN 611 Overvoltage category II, III (anticipated transient overvoltage 4 V), Pollution Degree 2 EN EN EN marms or less (measured with 2 MHz bandwidth equipment) EN 611 Overvoltage category II, III (anticipated transient overvoltage 4 V), Pollution Degree 2 EN EN EN Current consumption of the to 3276 (sum of real values). [ ] [ 3274 ] [ 3275 ] [ 3276 ] current consumption (ma) AC(f=5Hz) DC current to be measured (A) current consumption (ma) 6 AC (f=5hz) 5 DC current to be measured (A) Power Supply for Clamp-on Probes POWER SUPPLY 3269, Combination example of the Clamp-on probe Power supply for the Clamp on probe , CT67 series Supplies power when connected to a general-purpose instrument such as a recorder. current consumption (ma) AC (f=5hz) DC current to be measured (A) Basic specifications Compatible sensors Number of power supply connectors Output Power supply Dimensions and mass current consumption (ma) 6 AC (f=5hz) 5 DC current to be measured (A) Model CT67, CT671: up to 2 units Model CT67, CT671, , Model , 3274, 3275 or 3276: up to 1 unit 3274, 3275 or 3276: up to 4 units Note: May be used with up to 2 units of Model 3273 (not Note: Also up to 4 units for the discontinued -5 type), and up to 2 units of Models , 3274, 3275 Model 3273 or 3276 on condition that the measurement current is sufficiently low. 4 2 ±12 V ±.5 V, ±2.5 A (sum total of all channels) V to 24 V AC (free) 5/6 Hz 17 VA max. 8 mm (3.15 in)w 119 mm (4.69 in)h 2 mm (7.87 in)d, 1.1 kg (38.8 oz) Accessories Instruction manual 1, Power cord 1 ±12 V ±.5 V, 6 ma (sum total of all channels) V or 12/ 22/ 24 V AC (specify when ordering), 5/6 Hz 2 VA max. 73 mm (2.87 in)w 11 mm (4.33 in)h 186 mm (7.32 in)d, 1.1 kg (38.8 oz) Power cord 1, Instruction manual 1, Spare fuse 1
6 6 Wide-Bandwidth, High-Precision and Large Current Measurements Basic specifications AC/DC CURRENT SENSOR CT6865, 979 HIOKI PL23 (1-pin terminal) A large current measuring applications in the fields of electric and hybrid electric vehicles (CT6865) Operating temperature range of -3 C to 85 C (CT6865) Super high precision, ±.6% amplitude accuracy, ±.2 phase accuracy Wide-bandwidth DC to 2 khz (CT6865), khz (979) excellent frequency Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with the ) Offset - Temperature Characteristics (979) CAT III V HIOKI ME15W (12-pin terminal) Effect of conductor position (the wire 1 mm diameter) (979) CT6865 (Accuracy guaranteed for 1 year, Post-adjustmentaccuracy guaranteed for 1 year) Rated input current A AC/DC Max. allowable input Frequency Amplitude and Phase accuracy 12 A AC/DC (Continuous 18 A peak, up to Hz, up to 4 C (14 F), other requires derating ) Amplitude: DC to 2 khz Phase: DC to 1 khz DC ±.5 % rdg. ±.1 % f.s. (Phase: Not defined) 16 Hz f 66 Hz ±.5 % rdg. ±.1 % f.s., Phase: ±.2 deg. Amplitude is defined to 2 khz, Phase is defined to 1 khz 979 (Accuracy guaranteed for 6 months, Postadjustment accuracy guaranteed for 6 months) 5 A AC/DC 7 Arms ( Apeak, requires derating at frequency) Amplitude: DC to khz Phase: DC to khz DC, 45 Hz f 66 Hz (±.5 % rdg. ±.1 % f.s. (Phase: ±.2 deg) Defined to khz Power consumption 7 VA max. 5 VA max. (at A/55 Hz, ±12 V power requirement) (at 5 A/55 Hz, ±12 V power requirement) Output voltage rate 2 V /rated current value (voltage output with the Sensor Unit , use with a device having a 1 MΩ input resistance or higher) Max. rated voltage to earth AC/DC V (5/6 Hz, CAT III) Core diameter φ 36 mm (1.42 in) Operating temperature, humidity -3 C to +85 C (-22 F to 185 F) 8% rh or less (with no condensation) C to +5 C (32 F to 122 F) 8% rh or less (with no condensation) Power supply DC ±11 V to ±15 V (Power suppled via the , which supports to 24 V AC) 16 mm (6.3 in)w 112 mm (4.41 in)h 5 mm Dimensions and mass (1.97 in)d, 98 g (34.6 oz), cord length 3 m (9.84 ft) Accessories Instruction manual 1, Mark bands 6 16 mm (6.3 in)w 112 mm (4.41 in)h 5 mm (1.97 in)d, 85 g (3. oz), cord length: 3 m (9.84 ft) Sensitivity - Temperature Characteristics (979) Model : AC/DC CURRENT SENSOR CT6865 Model No. (Order Code) CT6865 CT (Note) ( A AC/DC) ( A AC/DC, 12 pin terminal) Model : AC/DC CURRENT SENSOR (5A AC/DC) (5 A AC/DC, 12 pin terminal) Delivering Wide-bandwidth and High-precision Current Measurement AC/DC CURRENT SENSOR CT6862, CT6863 HIOKI PL23 (1-pin terminal) CAT III V HIOKI ME15W (12-pin terminal) Super high precision, ±.6% amplitude accuracy, ±.2 phase accuracy Wide-bandwidth DC to 1 MHz (CT6862) excellent frequency Applications in the fields of electric and hybrid electric vehicles Wide operating temperature range fit for automobile applications Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with the ) Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year) CT6862 CT6863 Rated current 5 A AC/DC 2 A AC/DC Max. allowable input A (requires derating) 4 A (requires derating ) Frequency Amplitude and Phase accuracy Amplitude: DC to 1 MHz Phase: DC to 3 khz Amplitude: DC to 5 khz Phase: DC to 3 khz DC ±.5 % rdg. ±.1 % f.s. (Phase: Not DC ±.5 % rdg. ±.1 % f.s. (Phase: Not defined) defined) 16 Hz f 4 Hz ±.5 % rdg. ±.1 % f.s. 16 Hz f 4 Hz ±.5 % rdg. ±.1 % f.s. (Phase: ±.2 ) (Phase: ±.2 ) Defined to 1 MHz Defined to 5 khz Power consumption 5 VA max. (at 5 A/55 Hz, ±12 V power requirement) 6 VA max. (at 2 A/55 Hz, ±12 V power requirement) Output voltage 2 V/rated current range (voltage output with the Sensor Unit , use with a device having a 1 MΩ input resistance or higher) Max. rated voltage to earth AC/DC V (5/6 Hz, CAT III ) Core diameter φ 24 mm (.94 in) Operating temperature, humidity -3 C to +85 C (-22 F to 185 F), 8% rh or less (with no condensation) Power supply DC ±11 V to ±15 V (Power suppled via the , which supports to 24 V AC) Dimensions and 7 mm (2.76 in)w mm (3.94 in)h 53 mm (2.9 7 mm (2.76 in)w mm (3.94 in)h 53 mm (2.9 mass in)d, cord length: 3 m (9.84 ft), 34 g (12. oz) in)d, cord length: 3 m (9.84 ft), 35 g (12.3 oz) Accessories Instruction manual 1, Mark bands 6 Model : AC/DC CURRENT SENSOR CT6862 Model No. (Order Code) CT6862 CT (Note) (5 A AC/DC) (5 A AC/DC, 12 pin terminal) Model : AC/DC CURRENT SENSOR CT6863 Model No. (Order Code) CT6863 CT (Note) (2 A AC/DC) (2 A AC/DC, 12 pin terminal)
7 7 Shared options for CT6865, 979, CT6862, and CT6863 Options A SENSOR UNIT Power supply for current sensors when used alone CONNECTION CORD L9217 Cord has insulated BNC connectors at both ends, for signal output, 1.6 m (5.25 ft) length CONNECTION CORD 9165 Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length, not CE marked Options B Connects up to 2 cables in series, Cannot be used in combination with the CT6862/ 63 or 9277 to 9279 CONVERSION CABLE CONVERSION CABLE CT99 CT991 Convert HIOKI PL23 (1-pin) to Convert HIOKI ME15W (12-pin) HIOKI ME15W (12-pin) terminal to HIOKI PL23 (1-pin) terminal EXTENSION CABLE 976 Extension for 5 m (16.41 ft) length, HIOKI PL23 (1-pin) - HIOKI ME15W (12-pin) terminal Options C Connects up to 2 cables in series, Cannot be used in combination with the CT6862/ 63 or 9277 to 9279 EXTENSION CABLE CT992 Extension for 5m(16.41 ft) length, HIOKI ME15W (12-pin) - HIOKI PL23 (1-pin) terminal Options D For connecting to the F/V Unit 894 or Current Unit 8971 CONVERSION CABLE m (.66 ft) length, to connect the CT6841/43/44/45/46, CT6863/65, 979, to the F/V Unit 894 Cannot be used in combination with the CT6862 CONVERSION CABLE 9318 To connect the CT6841/43/44/45/46, CT6865/63, 9277/78/79, 927/71/72 to the 8971/4/51, 38 cm (14.96 in) length Ideal for Measuring Current with Low Frequencies such as Inverter Control Devices CLAMP ON SENSOR Model : CLAMP ON SENSOR (2/2 A AC) Note: This product cannot be used alone. The optional is required in order to supply power and connect the clamp to a Memory HiCorder or other instrument. The clamp can be directly connected the Power Meter , 3193, 3194, and 339. CAT III 6 V Superior low frequency and phase suitable for testing the current and power of inverter control devices Wide 1 Hz to khz frequency bandwidth perfect for harmonic analysis, FFT analysis and waveform monitoring Basic specifications (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months) Rated current 2 A AC, or 2 A AC (selectable) Max. allowable input 2 A range: 5 A rms Max. 2 A range: 3 A rms Max. Accuracy Amplitude: ±.3 % rdg. ±.1 % f.s. Phase: ±.2 (45 to 66 Hz) Frequency 1 Hz (±2 % rdg. ±.1 % f.s.) to khz (±3 % rdg. ±.1 % f.s.) Output rate 2 V/2 A rated current range, or 2 V/2 A rated current range (voltage output With the with the Sensor Unit , use with a device having a 1 MΩ input resistance or higher) Max. rated voltage to earth 6 V rms (CAT III) Core diameter φ 46 mm (1.81 in) Power supply DC ±11 V to ±15 V (Power suppled via the , which supports to 24 V AC) Power consumption 5 VA Max. (when measuring 2 A) Dimensions and mass 78 mm (3.7 in)w 188 mm (7.4 in)h 35 mm (1.38 in)d, 43 g (15.2 oz), cord length: 3 m (9.84 ft) Accessories Carrying case , Instruction manual 1, Mark bands 6 Model Compatibility (use with the connection cord) Compatible models Status Note , 3193, 3194 (use with the 962) 3 Directly connectable, Add.1% rdg. to accuracy MR8827, MR8847s (use with the 8971) 3 To connect via the Conversion Cable 9318 Model 894 for Memory HiCorders 3 Need the Conversion Cable 975, and use with the Conversion Cable 9318 to connect Model to the F/V Unit 894. (Not necessary when using Model 9272 due to different output wiring specifications.) Options A SENSOR UNIT Power supply for current sensors when used alone CONNECTION CORD L9217 Cord has insulated BNC connectors at both ends, for signal output, 1.6 m (5.25 ft) length CONNECTION CORD 9165 Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length, not CE marked CONVERSION CABLE 9318 To connect the CT6841/43, CT6865/63, 9277/78/79, 927/71/72 to the 8971/4/51, 38 cm (14.96 in) length *The 9355 is bundled CARRYING CASE 9355 For the , 927s, or other models Options B *The Clamp Sensor has different output wiring than the previous Both the 9318 and 975 are required in order to connect to the F/V Unit 894. CONVERSION CABLE m (.66 ft) length, to connect the CT6841/6843, CT6863/6865, 979, to the F/V Unit 894 Cannot be used in combination with the CT6862 EXTENSION CABLE 976 Extension for 5 m (16.41 ft) length, HIOKI PL23 (1-pin) - HIOKI ME15W (12-pin) terminal SENSOR UNIT Basic specifications Compatible sensor One of the CT6862 to CT6865 series, CT6841 to CT6846 series, 979, 9279 to 9277 series, , 927 to 9272 series Output Terminal BNC Terminal Power supply AC Adapter , to 24 V, 5/6 Hz, 2 VA Dimensions and mass 42 mm (1.65 in)w 82 mm (3.27 in)h 132 mm (5.2 in)d, 6 g (21.2 oz) Accessories Instruction manual 1, AC Adapter Power supply for the Current Sensor series when the sensors are used alone Model No. (Order Code) Compatible models...ct6865 (-5), 979 (-5) Compatible models CT6865 CT Model s (Requires CT99) 3 s (Requires CT99) 3 PW61 CT ratio: 2 s (Requires CT991) Model CT ratio: 2 3 s (Requires CT991) CT ratio: 2 Input unit model 962 for / 3193/ 3194 Model 8971 Model CT ratio: 2 s (Requires 9318) CT ratio: 2 975) CT ratio: 2 s (Requires CT991) CT ratio: 2 CT991) CT ratio: 2 s (Requires 9318, 975, and CT991) CT ratio: 2 3 s (Requires CT991) s (Requires 9318) s (Requires 9318 and 975) CT991) s (Requires 9318, 975, and CT991) Compatible models...ct6862 (-5), CT6863 (-5) Compatible models CT6862 CT CT6863 CT Model PW61 s (Requires CT99) 3 s (Requires CT99) 3 Model s(requires CT991) 3 s (Requires CT991) Input unit model 962 for / 3193/ s (Requires CT991) 3 s (Requires CT991) Model 8971 s (Requires 9318) s (Requires 9318) CT991) CT991) Model 894 N/A N/A s (Requires 9318 and 975) s (Requires 9318, 975, and CT991)
8 Rated current & Frequency AC/DC AC For wide-band current observatiom For high-precision current measurement up to 5A up to 15A 1mA class to 3A up to A up to 5A up to 2A up to 5A up to 2A up to 2A 3275 : DC to 2 MHz 3274 : DC to 1 MHz : DC to 5 MHz 3276 : DC to MHz CT6865 : DC to 2 khz 979 : DC to khz CT6863 : DC to 5 khz CT6862 : DC to 1 MHz (2A) : 1Hz to khz (2A) : 1Hz to khz Frequency (Hz) DC 1 1 1k 1k k 1M 1M M Wide-Band Current Probe Allows Direct Input to Oscilloscope CLAMP ON PROBE , 3274, 3275, 3276 Model : CLAMP ON PROBE (DC to 5 MHz, 3 Arms) 3275 Insulated conductor Model : CLAMP ON PROBE (DC to 1 MHz, 15 Arms) Note: Use the Power Supply 3269/3272 for general measurements or when power is not available from the Memory Hicorder. When performing continuous measurements, be aware of offset voltage drift Model : CLAMP ON PROBE (DC to 2 MHz, 5 Arms) Model : CLAMP ON PROBE (DC to MHz, 3 Arms) Options POWER SUPPLY 3272 For single sensor, 12/ 22/ 24 V AC, specify when ordering POWER SUPPLY 3269 For four sensors, V to 24 V AC CONVERSION CABLE 9319 To connect the and the 894, Note: cannot be used with the 3274, 3275, 3276 to connect the 894 via this cable 9319 WARNING 1. To avoid short circuits and electric shock accidents when using a clamp-on sensor, use only with power lines carrying voltages within the rating limit of the sensor. 2. To avoid short circuits and electric shock accidents when the clamp-on sensor is open, do not use on bare conductors. Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. Test Equipment Depot Washington Street Melrose, MA 2176 TestEquipmentDepot.com All information correct as of July 28, 216. All specifications are subject to change without notice. Current_sensor_E6-67E Printed in Japan
Wide-band Models from DC to 100 MHz
CLAMP SENSOR Wide-band Models from to 1 MHz CLAMP ON PROBE 3276 1 CLAMP ON PROBE 3273-5 to 3276 Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due
More informationWide-band Models from DC to 100 MHz
CLAMP SENSOR Wide-band Models from DC to 1 MHz 3273-5 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available
More informationUser s Manual Current Probe. IM E 2nd Edition IM E
User s Manual 700937 Current Probe 2nd Edition Introduction Thank you for purchasing the 700937 Current Probe. This Instruction Manual contains useful information about the instrument s functions and operating
More informationUser s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation
User s Manual 701932 Current Probe Yokogawa Electric Corporation 1st Edition Foreword Revisions Thank you for purchasing the 701932 Current Probe. This user's manual contains useful information about the
More informationWorld-Class Accuracy & Measurement Range (40 Conventional Models)
AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)
More informationUser s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation
User s Manual 701930 Current Probe Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the Current Probe (Model 701930). This instruction manual contains useful information
More informationINSTRUCTION MANUAL CLAMP ON PROBE
INSTRUCTION MANUAL 3275 CLAMP ON PROBE Contents Introduction 1 Inspection 1 Notes on Safety 1 Notes on Use 4 Chapter 1 Overview 9 1.1 Product Overview 9 1.2 Features 9 1.3 Names of Parts 10 1.4 Parts
More informationAC/DC current clamps (1/2) E N series
AC/DC current clamps The clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. These clamps' narrow, elongated design makes them ideal areas
More informationUser s Manual Current Probe IM E. 8th Edition
User s Manual 701931 Current Probe 8th Edition Thank you for purchasing the Current Probe (Model 701931). This instruction manual contains useful information about the instrument s functions and operating
More informationSERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.
Pinces Current ampèremetriques clamps for AC/DC pour current courant AC SERIE E N The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over
More informationUser s Manual Current Probe IM E. 6th Edition
User s Manual 701932 Current Probe 6th Edition Thank you for purchasing the 701932 Current Probe. This user s manual contains useful information about the functions and operating procedures of the 701932
More informationTT-SI MHz Active Differential Probe
INSTRUCTION MANUAL TT-SI 9110 100MHz Active Differential Probe These probe is in compliance with EN61010-031:2002+A1:2008 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual:
More informationTT-SI 9001 / TT-SI MHz Active Differential Probes
INSTRUCTION MANUAL TT-SI 9001 / TT-SI 9002 25MHz Active Differential Probes These probes are in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this
More informationFlexible AC current probes
Flexible AC current probes Making use of the principle of Rogowski coils, the MiniFLEX models are flexible sensors offering a wide dynamic range for measuring AC intensities and viewing high-speed current
More informationE Series 9.00 (1/2) E series
Clamp-on AC/DC current probes E Series The clamps use Hall effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. The elongated, narrow design of these clamps
More informationFLEXIBLE CURRENT PROBES
FLEXIBLE CURRENT PROBES AmpFlex, LongLife AmpFlex & FlexProbe Ranges from 30 to 30,000Arms (AmpFlex Flexible Current Probes) Single or dual range to measure up to 3000A (LongLife AmpFlex Flexible Current
More informationDIGITAL HiTESTER 3237, 3238, 3239
DIGITAL HiTESTER,, 3239 4-terminal Ω function Advanced model Economically priced 3239 Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed 5 1 /2 digit DMM The DIGITAL
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BATTERY IMPEDANCE METER BT4560 Component measuring instruments Determine Li-ion
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation
More informationAC/DC Current Oscilloscope Probe Model SL261
AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated
More informationRIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc
User s Guide RP1003C/RP1004C/RP1005C Current Probe Mar. 2013 RIGOL Technologies, Inc Guaranty and Declaration Copyright 2013 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is
More informationAccurately measure devices up to 1000 V/65 A AC/DC with direct input
POWER METER PW3336, PW3337 High-precision, 3-channel power meter with built-in harmonic measurement Accurately measure devices up to 1000 V/65 A AC/DC with direct input The PW3336 (2-channel) and PW3337
More information3331, 3332 POWER HiTESTER
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com An Energy Saving Support Tool 2002 3331, 3332 POWER HiTESTER Power measuring instruments 3332: Single-phase, 2-wire type that
More informationTT-SI MHz Active Differential Probe
INSTRUCTION MANUAL TT-SI 9101 100MHz Active Differential Probe These probe is in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual: WARNING.
More informationHigh-accuracy measurement of standby to operating power
POWER METER PW3335 Single-Phase AC/DC Power Meter High- of standby to operating power Wide measurable range : 10 μa to 30 A, 60 mv to 1000 V Basic for voltage, current and power : ±0.1%* Frequency bandwidth
More informationAgilent N2780A, N2781A, N2782A, and N2783A Current Probes
Agilent N2780A, N2781A, N2782A, and N2783A Current Probes User s and Service Guide Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by
More informationHigh-accuracy measurement of standby to operating power
POWER METER PW3335 Power Measuring Instruments Single-Phase AC/DC Power Meter High- of standby to operating power Wide measurable range : 10 μa to 30 A, 60 mv to 1000 V Basic for voltage, current and power
More informationA Full Line-up of Digital and Analog Clamp Meters to Suit Any Need
CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and
More informationRS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.
3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER Field measuring instruments 2001 Support efficient data collection RS-232C communication All HiTESTERs For Personal
More informationTA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.
TA041 25 MHz ±700 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING
More informationAC/DC CLAMP METER CM4371, CM4373
AC/DC CLAMP METER CM4371, CM4373 Field measuring instruments CM4371 : 600 A AC/DC CM4373 : 2000 A AC/DC Speedy Performance of Professional Testing Made in Japan for rock-solid quality. Rugged clamp meters
More informationThe PW3336 (2-channel) and PW3337 (3-channel) can measure DC and a variety of power connections ranging from single-phase 2-wire to 3-phase 4-wire*.
POWER METER PW3336/PW3337 Power Measuring Instruments High-precision, 3-channel power meter with built-in harmonic measurement Accurately measure devices up to 1000 V/65 A AC/DC with direct input The PW3336
More informationTT-SI MHz DIFFERENTIAL PROBE
TT-SI 9110 100MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC - 1010. 2-031 CATⅢ, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual: WARNING.
More information1 of 6 03/12/2012 14:56 2012-12-03 HAMEG > Products > Accessories > Probes http://www.hameg.com/186.0.html P R O B E S H Z 5 6-2 * AC/ DC Current Clamps This AC/DC Current Probe is used to measure currents
More informationSTANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool
An Energy Saving Support Tool POWER HiTESTER Power Measuring Instruments 3332 STANDBY MODE OFF MODE Single-phase, 2-wire type that can accurately measure even standby power Accurate evaluation of consumption
More informationAC/DC Current Probe TCP0150 Datasheet
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com AC/DC Current Probe TCP0150 Datasheet Low noise and DC drift Provides automatic units scaling and readout
More informationFluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Fluke 1750 Three-Phase Power Recorder Technical Data Never miss capturing a disturbance
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low
More informationHigh-precision portable RESISTANCE METER
8 High-precision portable RESISTANCE METER measures from µω to MΩ Features High-precision specs in a portable package(high accuracy of 0.02% rdg.) Design is ideal for maintenance and testing/measurement
More informationTA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.
TA043 100 MHz x10/x100 Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2 031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING
More information10.00 (1/2) PAC series
Clamp-on AC/DC current probes PAC Series The is a range of professional AC/DC clamp-on current probes designed to meet the very latest in safety and performance standards. There are two different jaw designs
More informationRP1003C/RP1004C/RP1005C
User s Guide RP1003C/RP1004C/RP1005C Current Probe Apr. 2016 RIGOL TECHNOLOGIES, INC. Guaranty and Declaration RIGOL Copyright 2013 RIGOL TECHNOLOGIES, INC. All Rights Reserved. Trademark Information
More informationWide Spectrum Power Meter for Comprehensive Device Assessment
POWER HiTESTER 3193-10 Wide Spectrum Power Meter for Comprehensive Device Assessment Printer is optional unit DC/0.5Hz to 1MHz broad-band POWER HiTESTER measures up to 6 systems simultaneously. The POWER
More information5MHz FUNCTION GENERATOR
5MHz FUNCTION GENERATOR MODEL GF-8056 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com User s Manual Elenco TM Electronics, Inc.
More informationCurrent clamps for AC current
Current clamps for AC current Y series The Y series clamps are designed to be both rugged and versatile whilst remaining easy to use. The jaws are designed so that the clamps can be hooked onto cables
More informationCurrent clamps for AC current
Current clamps for AC current "C100" series The "C100" series is a range of thirteen transformer clamps with all the advantages of our old "C30" series clamps whilst incorporating considerable improvements,
More informationRugged, Professional and Ready for the Field. Capture high- to low-voltage signals in a single device. MEMORY HiCORDER MR8880
MEMORY HiCORDER MR8880 Capture high- to low-voltage signals in a single device Rugged, Professional and Ready for the Field CAT III 600 V insulation performance Maximum 600V AC/DC input - no need for a
More informationINSULATION TESTER SERIES Selection guide
INSULATION TESTER SERIES Selection guide Model IR4056 IR4057 IR4053 IR4016 to IR4018 3490 3455 Basic Specifications (Bar graph) Analog Meter IR4016 IR4017 IR4018 Analog Meter backlight function 3 3 3 3
More informationAn Evolution in Stable Measurements
RESISTANCE METER, An Evolution in Stable s Perfect for Taping Machines and Sorting Machines Supports Resistance s for Miniature 008004-size Electronic Parts (0.25 mm 0.125 mm) 99 Washington Street Melrose,
More informationAgilent 1146A AC/DC Oscilloscope Current Probe
A User s Guide Publication number 01146-92003 May 2005 Copyright Agilent Technologies 1996-2005 All Rights Reserved Contents Receiving Your Shipment -2 Packaging -2 Description -3 Compatibility -3 Control
More informationManage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance
BATTERY IMPEDANCE METER BT456 Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance The Ultimate Instrument for Measuring Large-Capacity Li-ion Batteries for EVs 2 Improve
More informationsupplies and frequency converters. BumbleBee is also very effective in fast transient measurements
High Voltage Differential Probe Order-No: 880-102-501 Features: 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating Temperatures (0 C to +50 C) High CMRR 4 Mode Attenuation Useable
More informationA Full Line-up of Digital and Analog Clamp Meters to Suit Any Need
CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI
More informationPreface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention
AC/DC Low Frequency Current Probe CPL2000 (2000A/10kHz) Shenzhen Zhiyong Electronics Co., Ltd www.cybertek.cn Preface First of all, thank you for purchasing our products, this instruction manual is the
More informationBumbleBee. High Voltage Differential Probe Ord.-No: Features:
High Voltage Differential Probe Ord.-No: 880-102-501 Features: 2000 V rms Measurement Category I, 6000 V transient Overvoltage 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com MEMORY HiCORDER MR8870-20 Recorders Oscilloscope-like Waveform Observation, Plus
More informationTA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.
TA046 800 MHz ±30 V Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2-031 CAT I, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING Warning
More informationRugged, Professional and Ready for the Field. Capture high- to low-voltage signals in a single device. MEMORY HiCORDER MR8880
MEMORY HiCORDER MR8880 Capture high- to low-voltage signals in a single device Rugged, Professional and Ready for the Field CAT III 600 V insulation performance Maximum 600V AC/DC input - no need for a
More informationFluke 3540 FC Three-Phase Power Monitor
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor THREE-PHASE MONITORING AND STREAMING Monitor three-phase
More informationNOTE: Fully read and understand this manual before using this Digital Multimeter.
ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and
More informationMODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR
MODEL 9050 EXTENDED SPECIFICATIONS Ü 50ppm TRANSPORTABLE CALIBRATOR 9050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum
More informationRS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.
2004 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER Field measuring instruments Support efficient data collection RS-232C communication All HiTESTERs For Personal
More information1587/1577 Insulation Multimeters
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationAC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER
AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual
More information3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.
2004 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3
More informationDS10000ULFS-10V/10kA
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 11kA Features Linearity error maximum +/- 7ppm
More informationPreface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t
AC/DC Current Probe CPL8100A (100A/600kHz) CPL8100B (100A / 2MHz) Shenzhen Zhiyong Electronics Co., Ltd www.cybertek.cn Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing
More informationFor easy-to-use loggers, look no further! WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515 Data Loggers For easy-to-use
More informationAC/DC CLAMP METER CM4370 series
AC/DC CLAMP METER CM4370 series CM4371, CM4372 : 600 A AC/DC CM4373, CM4374 : 2000 A AC/DC Speedy Performance of Professional Testing Made in Japan for rock-solid quality. Rugged clamp meters for the toughest
More informationPOWER HiTESTER 3331, 3332
An Energy Saving Support Tool POWER HiTESTER 3331, 3332 Power measuring instruments 3332: Single-phase, 2-wire type that can accurately measure even standby power 3331: Single-phase, 3-wire and three-phase,
More informationPreface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u
AC/DC Current Probe CPL8100A (100A/600kHz) CPL8100B (100A / 2MHz) Shenzhen Zhiyong Electronics Co., Ltd www.cybertek.cn Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing
More informationAgilent 1147A 50 MHz Current Probe
Agilent 1147A 50 MHz Current Probe User s Guide Publication number 01147-92006 January 2008 For Safety information, Regulatory information, and publishing information, see the pages at the end of this
More informationCLAMP ON HiTESTER SERIES
CLAMP ON HiTESTER SERIES Field Measuring Instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI
More informationHigh precision measurement system for current and voltage IHC-A/B-RM01/03
Measurement Offset-free and low-noise 16 bit data acquisition system ISA-ASIC Internal sample rate 3,500 Hz Communication Standard RS232- or RS485 interface Advantages Direct measurement on the bus bar
More informationAgilent N2893A 100 MHz Current Probe
Agilent N2893A 100 MHz Current Probe User s Guide Publication number N2893-97000 January 2011 For Safety information, Regulatory information, and publishing information, see the pages at the end of this
More informationMD 200A High voltage differential probe
1 MD 200A High voltage differential probe User Manual 601-265B MD 200A High voltage differential probe User Manual MD 200A high voltage differential probe contents 1 Safety terms and symbols 5 2 Safety
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free
User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting
More information1. BP4620 SPECIFICATIONS
1. SPECIFICATIONS 1. SPECIFICATIONS 1-1 1.1 Specification Conditions 1-2 1.2 Output 1-3 1.3 Output Limiters 1-5 1.4 Signal Sources 1-6 1.5 Monitor Output 1-7 1.6 Measurement Functions 1-7 1.7 Sequence
More informationAC/DC CLAMP METER CM4370 series
AC/DC CLAMP METER CM4370 series CM4371, CM4372 : 600 A AC/DC CM4373, CM4374 : 2000 A AC/DC Speedy Performance of Professional Testing Made in Japan for rock-solid quality. Rugged clamp meters for the toughest
More informationA Full Line-up of Digital and Analog Clamp Meters to Suit Any Need
CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI
More informationFluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.
Fluke 1750 Three-Phase Power Recorder Technical Data Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic. Capture every measurement, every event, on
More informationKeysight 1147B 50 MHz Current Probe. User s Guide
Keysight 1147B 50 MHz Current Probe User s Guide Notices Keysight Technologies, Inc. 2000-2016 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval
More informationFluke 3540 FC Three-Phase Power Monitor
TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor The 3540 FC Three-Phase Power Monitor is a compact device to monitor three-phase systems and stream data to the Fluke Connect Cloud. The measurement
More informationUSER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information
More informationDECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY Manufacturer's Name: Transmille Ltd. Manufacturer's Address: Unit 4, Select Business Centre Lodge Road Staplehurst TN12 0QW. United Kingdom. Declares, that the product Product
More informationMODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR
MODEL 9041 EXTENDED SPECIFICATIONS 25ppm TRANSPORTABLE CALIBRATOR 9041 EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum
More informationN acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs
With compliments All specifications apply to the TDS 200-Series Digital Real-Time Oscilloscope with a P2100 probe with the Attenuation switch set to 10X unless noted otherwise. To meet specifications,
More informationA Full Line-up of Digital and Analog Clamp Meters to Suit Any Need
CLAMP ON HiTESTER Series A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis Please see www.hioki.com for list of supported regions. 2 Selection
More information15. Specifications WF1947/WF
15. Specifications 15.1 Oscillation Mode...15-2 15.2 Waveform...15-2 15.3 Frequency, Phase...15-3 15.4 Output Characteristics...15-3 15.5 Signal Characteristics...15-5 15.6 Modulated Oscillation Mode...15-7
More informationDS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V
More informationDM-5 Power Quality Analyzer
amprobe.com DM-5 Power Quality Analyzer With Feature Packed Software, most Compact High Performance Power Quality Analyzer in its Class Poor power quality is costly not only can it drive up energy bills
More informationUser Manual Current Probe Instruction Manual
User Manual Current Probe Instruction Manual 2015 SIGLENT TECHNOLOGIES CO.,LTD CP5000 Series Current Probe Safety Notices Note A Note notice denotes important instructions. CAUTION A CAUTION notice denotes
More informationRIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc
User s Guide RP1000D Series High Voltage Differential Probe Feb. 2013 RIGOL Technologies, Inc Guaranty and Declaration Copyright 2012 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information
More informationAC/DC CLAMP METER AC CLAMP METER CM4000 series
AC/DC CLAMP METER AC CLAMP METER CM4000 series NEW NEW CM4375 CM4376 1000 A AC/DC max CM4141 CM4142 2000 A AC max Please see www.hioki.com for list of supported regions. Models with Bluetooth support:
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER DSM-8104, DSM-8542
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER, DIGITAL SUPER MEGOHMMETERS (Single-Channel) (Four-Channel) Options Supporting
More informationDS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 0 ppm offset Current
More informationOffering a new approach to energyrelated
CLAMP ON POWER HiTESTER 3169 Offering a new approach to energyrelated measurement such as energy conservation, ISO14001 testing, equipment diagnosis, and harmonics measurement. The photo shows the 3169-21
More informationArbitrary/Function Generator AFG1000 Series Datasheet
Arbitrary/Function Generator AFG1000 Series Datasheet 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compatible with TekSmartLab
More informationDVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use