MODEL: R7C. Remote I/O R7 Series. CC-Link I/O MODULE. [2] POWER INPUT DC Power R: 24 V DC

Size: px
Start display at page:

Download "MODEL: R7C. Remote I/O R7 Series. CC-Link I/O MODULE. [2] POWER INPUT DC Power R: 24 V DC"

Transcription

1 MODEL: RC Remote I/O R Series CC-Link I/O MODULE (CE not available. Option /UL Not selectable) MS: Potentiometer input, points (Option /UL Not selectable) CTE: AC current input, points, Clamp-on current sensor CLSE use (Option /UL Not selectable) PA: Totalized pulse input, points, (CE not available, option /UL Not selectable) (Terminating resistor incorporated) YV: DC voltage output, points YS: DC current output, points ORDERING INORMATI Basic module: RC-[]-[][] Specify a code from below for each [] through []. (e.g. RC-DCA-R/Q) Specify the specification for option code /Q (e.g. /C) If you need factory setting, use Ordering Information Sheet (No. ESU--x). Extension module: RC-[][] Specify a code from below for each [] and []. (e.g. RC-ECA/Q) Specify the specification for option code /Q (e.g. /C) BASIC MODULE: RC [] [][] [] I/O TYPE DA: Discrete input, points DCA: NPN transistor output, points (Not usable with RC-EA or RC-EA) DCB: PNP transistor output, points (Not usable with RC-EA or RC-EA) DCC: Relay contact output, points (Option /UL Not selectable) (Not usable with extension modules) DCE: Relay contact output, points (CE not available. Option /UL Not selectable) (Not usable with RC-EA or RC-EA) (Terminating resistor incorporated) RR: Remote control relay control, points (CE not available. Option /UL Not selectable) (Not usable with extension modules) (Terminating resistor incorporated) SV: DC voltage/current input ( V/ ma), points TS: Thermocouple input, points RS: RTD input, points RTA: Thermistor input, points [] POWER INPUT DC Power R: V DC (Operational voltage range V ± %, ripple %p-p max.) Universal AR: V AC/ V DC (Only for RC-RR and PA) (Operational voltage range: V ± %; ripple %p-p max.) [] OPTIS Standards & Approvals blank: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) (UL not available) EXTENSI MODULE: RC [][] [] I/O TYPE EA: Discrete input, points EA: Discrete input, points ECA: NPN transistor output, points ECA: NPN transistor output, points ECB: PNP transistor output, points ECB: PNP transistor output, points ECC: Relay contact output, points (CE not available. Option /UL Not selectable) [] OPTIS STANDARDS & APPROVALS blank: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) (UL not available) RC SPECIICATIS ES- Rev. Page /

2 MODEL: RC SPECIICATIS O OPTI: Q COATING (or the detail, refer to M-System's web site.) /C: Silicone coating /C: Polyurethane coating /C: Rubber coating UTIS & EATURES The RC interfaces analog and discrete I/O signals with a PLC via CC-Link. A basic module can be attached with an extension module. (Exceptions: refer to the I/O type specifications) By combining two modules, single station can handle mixed analog and discrete signals, -point discrete inputs, - point discrete outputs, -point discrete I/Os and other combinations of signals. Only the combination of basic discrete output and extension discrete input modules is not available. Input sensor type (thermocouple, RTD) and range can be selected with the front DIP switches for all channels. In order to set different selections for individual channels, zero/span adjustments, scaling and temperature unit, use the PC Configurator Software (model: RC) RELATED PRODUCTS PC configurator software (model: RC) Downloadable at M-System s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. Clamp-on current sensor (model: CLSE) or RC-CTE, the clamp-on current sensors must be ordered separately. Required number depends upon the channel number. PACKAGE ILUDES... Terminating resistor ( Ω,. W) (Not provided for models terminating resistor incorporated) GENERAL SPECIICATIS Common Specifications Power input: V AC ± % ( / Hz) V DC ± %; ripple %p-p max. Insulation resistance: MΩ with V DC Dielectric strength: V minute (between isolated circuits) Operating temperature: - to + C ( to ) Operating humidity: to %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Storage temperature: - to + C (- to + ) Mounting: DIN rail ( mm wide) Connection: M separable screw terminals (torque. N m) Screw terminal material: Nickel-plated steel Solderless terminal: Refer to the drawing at the end of the section. Recommended manufacturer: Japan Solderless Terminal M.Co.Ltd, Nichifu Co.,ltd Applicable wire size:. to. mm (AWG to ) Housing material: lame-resistant resin (gray) Status indicator LED: PWR (Refer to the instruction manual for details) DC Power Current Consumption & Weight RC-DA: Approx. ma, g (. lb) RC-DCA: Approx. ma, g (. lb) RC-DCB: Approx. ma, g (. lb) RC-DCC: Approx. ma (approx. ma), g (. lb) RC-DCE: Approx. ma (approx. ma), g (. lb) RC-RR: Approx. ma, g (. lb) RC-SV: Approx. ma, g (. lb) RC-TS: Approx. ma, g (. lb) RC-RS: Approx. ma, g (. lb) RC-RTA: Approx. ma, g (. lb) RC-MS: Approx. ma, g (. lb) RC-CTE: Approx. ma, g (. lb) RC-PA: Approx. ma, g (. lb) RC-YV: Approx. ma, g (. lb) RC-YS: Approx. ma, g (. lb) RC-EA: Approx. ma, g (. lb) RC-EA: Approx. ma, g (. lb) RC-ECA: Approx. ma, g (. lb) RC-ECA: Approx. ma, g (. lb) RC-ECB: Approx. ma, g (. lb) RC-ECB: Approx. ma, g (. lb) RC-ECC: Approx. ma, g (. lb) The consumed current of supply power for the output is shown in (). AC Power Current Consumption RC-RR: Approx. ma RC-PA: Approx. ma Station Type RC-DA: Remote I/O RC-DCA: Remote I/O RC-DCB: Remote I/O RC-DCC: Remote I/O RC-DCE: Remote I/O RC-RR: Remote I/O RC-SV: Remote device RC-TS: Remote device RC-RS: Remote device RC-RTA: Remote device RC SPECIICATIS ES- Rev. Page /

3 MODEL: RC RC-MS: Remote device RC-CTE: Remote device RC-PA: Remote device RC-YV: Remote device RC-YS: Remote device Recommended solderless terminal. (.) max (.) max mm (inch) CC-Link COMMUNICATI CC-Link: Ver.. Network cable: CC-Link cable designated by Mitsubishi Electric Station address setting: - (rotary switch, default:) Baud rate setting: kbps (default), kbps,. Mbps, Mbps, Mbps (rotary switch) Status indicator LEDs: RUN, ERR, SD, RD STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN -- EMS EN -- Low Voltage Directive (Only RC-DCC conforms to it. Refer to the instruction manual for the detailed information.) EN -, EN -- Measurement Category II (output) Pollution Degree Output to power: Basic insulation ( V) RoHS Directive EN Approval: UL/C-UL nonincendive Class I, Division, Groups A, B, C, and D (ANSI/ISA-.., CAN/CSA-C. No.) UL/C-UL general safety requirements (UL -, CAN/CSA-C. No.-) RC SPECIICATIS ES- Rev. Page /

4 MODEL: RC EXTERNAL VIEW BASIC MODULE SIDE VIEW RT VIEW Station Address Setting Rotary SW Status Indicator LED * Baud Rate Setting Rotary SW Operating Mode Setting DIP SW (SW) PC Configurator Jack * Discrete I/O Status Indicator LED * TERM X X PWR ERR RD RUN SD STATI ADD. B.RATE A B C D E CN. Terminating Resistor SW * CC-Link, Power Supply Terminals I/O Terminals * *. Refer to Status Indicator LED section for detailed information. *. Not available with discrete I/O modules. *. Not available with analog I/O modules. *. screw terminals for analog output modules. *. Only for RC-DCE, RR and PA. EXTENSI MODULE DISCRETE, POINTS Discrete I/O Status Indicator LED I/O Terminals RC SPECIICATIS ES- Rev. Page /

5 MODEL: RC DISCRETE, POINTS Discrete I/O Status Indicator LED A B C D E I/O Terminals CNECTI DIAGRAMS POWER SUPPLY, CC-LINK TERMINAL ASSIGNMENT Except RC-RR and PA DA DG + V DB SLD V RC-RR and PA DA DG U (+) DB SLD V (-) NO. ID UTI, NOTES NO. ID UTI, NOTES DB SLD DA DG + V V White Shield Blue Yellow Power input ( V DC) Power input ( V DC) DB SLD DA DG U (+) V (-) White Shield Blue Yellow Power input Power input MASTER CNECTI Master Unit TERMINATOR DA DB DG SLD blue white yellow Remote Unit DA DB DG SLD Remote Unit TERMINATOR DA DB DG SLD Be sure to connect the terminating resistor included in the product package to the unit at both ends of transmission line. Or turn the terminating resistor SW for models with the resistor incorporated. The terminator must be connected across DA and DB. The Master Unit can be located other than at the extreme ends of transmission line. RC SPECIICATIS ES- Rev. Page /

6 INDICATOR LED STATUS INDICATOR LED PWR RUN ERR BL BL SD BL BL RD BL BL BL BL BL BL BL BL BL BL BL BL BL BL / =, =, BL = Blinking ---- = Inconceivable in normal operations (e.g. LED failure) STATUS Communicates normally with occasional CRC errors due to noise interference. Communicates normally but the Baud Rate and/or Station Address switches failed. ERR LED blinks approximately in. second intervals CRC error found in the received data. Unable to respond Normal communication ---- Unable to receive data addressed to the station Performs the interval-timed responses but CRC error found in receiving the refresh data CRC error found in the data addressed to the station Link is not started No data addressed to the station. Or unable to receive data addressed to the station due to noise interference. (Missing parts of the data sent from the master) Unable to receive data due to wire breakdown aulty Baud Rate and/or Station Address setting Power input removed. Or power supply failure. DISCRETE I/O STATUS INDICATOR LED Discrete I/O modules, including those for extensions, have LED indicators showing I/O signal status. Totalized pulse modules have LED indicators showing input signal status. Contact : LED Contact : LED MODEL: RC DATA CVERSI % DATA CVERSI Analog input data is converted into digital representations of % proportional to each scaled range. The converted % values are multiplied by and expressed in bits. Overrange input is possible from - to +% of the nominal range. When the signal exceeds the limit, the data is fixed at -% or +% respectively. Negative value is represented in ʼs complements. Input Range V DC Input Value -. V V V. V Input % -% % % % Converted Data, Decimal - Converted Data, Hex A CEC (CEC) () -... (V) - (A) Analog output is converted in the reverse order of the input data. The output range V DC is expressed as at. V (%) and at V (%). RC SPECIICATIS ES- Rev. Page /

7 MODEL: RC ENGINEERING UNIT CVERSI Engineering unit value C or K is multiplied by and expressed in bits. data is represented in engineering unit value, without multiplication. Engineering unit value A is multiplied by or, expressed in bits. Negative value is represented in ʼs complements. Input TYPE K Thermocouple Input Value - C - C C C Converted Data, Decimal - - Converted Data, Hex A () () - - ( C) - (A) - () COUNT VALUE The count value is -bit data. It is divided in words of bits represented with addresses.the lower address is allocated in the lower word (LSB) and the upper address in the upper word (MSB). The count value is -. The maximum count value available is -. In case of overflow, the vaule is reset to or (configurable) from which the count will restart. The preset of the count value is also available. Use the RC or commands for the configuration. RC SPECIICATIS ES- Rev. Page /

8 MODEL: RC DATA ALLOCATI RC-DA Interval-timed Response (X) RX(n+) to RX(n+) (RC-DA) Refresh Data (Y) RC-DA + RC-EA Interval-timed Response (X) RX(n+) to RX(n+) (RC-DA) RX(n+) to RX(n+) (RC-EA) Refresh Data (Y) RC-DA + RC-ECx Interval-timed Response (X) RX(n+) to RX(n+) (RC-DA) Refresh Data (Y) RY(n+) to RY(n+) (RC-ECx) RC-DCx Interval-timed Response (X) Refresh Data (Y) RY(n+) to RY(n+) (RC-DCx) RC-DCx + RC-ECx Interval-timed Response (X) Refresh Data (Y) RY(n+) to RY(n+) (RC-DCx) RY(n+) to RY(n+) (RC-ECx) RC-DCx Interval-timed Response (X) Refresh Data (Y) RY(n+) to RY(n+) (RC-DCC) RC-DCE + RC-ECx Interval-timed Response (X) Refresh Data (Y) RY(n+) to RY(n+) (RC-DCE) RY(n+) to RY(n+) (RC-ECx) RC-RR Interval-timed Response (X) RX(n+) to RX(n+) (RC-RR) Refresh Data (Y) RY(n+) to RY(n+) (RC-RR) RC SPECIICATIS ES- Rev. Page /

9 MODEL: RC RC-PA Data allocation Interval timed Response (X) Refresh Data (Y) RX (n+) RX (n+) D RX (n+) : Command RY (n+) RY (n+) A RY (n+) : Command RX (n+) RY (n+) Interval-timed Response (X) Refresh Data (Y) RWr (n+) Input extension RWw (n+) Output extension RWr (n+) RWw (n+) RWr (n+) Count data (LSB) RWw (n+) Preset data (LSB) RWr (n+) Count data (MSB) RWw (n+) Preset data (MSB) Data allocation Interval-timed Response (X) Refresh Data (Y) RX (n+) RX (n+) D RX (n+) : Command RY (n+) RY (n+)a RY (n+) : Command RX (n+) Input extension RY (n+) Output extension Interval-timed Response (X) Refresh Data (Y) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RWr (n+) ch Count data (LSB) RWw (n+) ch Preset data (LSB) RWr (n+) ch Count data (MSB) RWw (n+) ch Preset data (MSB) RC SPECIICATIS ES- Rev. Page /

10 MODEL: RC ANALOG INPUT, POINTS Models RC-SV, RC-TS, RC-RS, RC-RTA, RC-MS, RC-CTE Interval-timed Response (X) Refresh Data (Y) RWrn+ Analog input RWwn+ + Analog input + + Analog input + + Analog input + Without Extension Module Interval-timed Response (X) RX(n+) to RX(n+) (Status) Reserved Refresh Data (Y) With Extension Module RC-EA Interval-timed Response (X) RX(n+) to RX(n+) (RC-EA) Reserved Refresh Data (Y) With Extension Module RC-ECx Interval-timed Response (X) RX(n+) to RX(n+) (Status) Reserved Refresh Data (Y) RY(n+) to RY(n+) (RC-ECx) ANALOG OUTPUT, POINTS Models RC-YV, RC-YS Interval-timed Response (X) Refresh Data (Y) RWrn+ RWwn+ Analog output + + Analog output Without Extension Module Interval-timed Response (X) Reserved Refresh Data (Y) With Extension Module RC-EA Interval-timed Response (X) RX(n+) to RX(n+) (RC-EA) Reserved Refresh Data (Y) With Extension Module RC-ECx Interval-timed Response (X) Reserved Refresh Data (Y) RY(n+) to RY(n+) (RC-ECx) RC SPECIICATIS ES- Rev. Page /

11 MODEL: RC I/O DATA DESCRIPTIS DISCRETE I/O : : Input (Output ) Input (Output ) Input (Output ) Input (Output ) : : Input (Output ) points Input (Output ) : : points Input (Output ) RC-RR eedback input eedback input eedback input eedback input Not Used Output Output Output : : RC PA RX (n+) RY (n+) Channel No. Command acknowledge Data acknowledge Ready signal Error display Channel No. Command acknowledge Data selection ANALOG I/O -bit binary data Negative values represented in s complements RC SPECIICATIS ES- Rev. Page /

12 MODEL: RC STATUS Analog input modules without extension module (models: RC-SV, RC-TS, RC-RS, RC-RTA, RC-MS, RC-CTE) can show input status of each channel. Analog output modules (models: RC-YS, RC-YV), discrete I/O modules (models: RC-DA, RC-DCx, RC-RR) and Totalized pulse input module (RC-PA) show '' at the same address. Burnout, input range error ( -%, +%) : Normal : Error ADC error (no response from ADC) : Normal : Error Input (Burnout, input range error) Input (Burnout, input range error) Input (Burnout, input range error) Input (Burnout, input range error) Input (ADC error) Input (ADC error) Input (ADC error) Input (ADC error) : EXTENSI MODULE A basic module can be attached with one extension module. The extension module is powered from the basic module. By combining two modules, single station can handle mixed analog and discrete signals, -point discrete inputs, -point discrete outputs, -point discrete I/Os and other combinations of signals. MODULE COMBINATIS (Basic module: Extension modules) RC-DA: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-DCA* : RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-DCB* : RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-DCC* : ---- RC-DCE* :RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-RR* : ---- RC-SV: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-TS: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-RS: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-RTA: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-MS: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-CTE: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-PA: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-YV: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC RC-YS: RC-EA, RC-EA, RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC *. Not usable with RC-EA or RC-EA. *. Not usable with 'Extension' modules. OUTPUT AT THE LOSS O COMMUNICATI or the extension module RC-DA, RC-DCx or RC-DCE The extension modules (RC-ECA, RC-ECA, RC-ECB, RC-ECB, RC-ECC) are set to Reset Output or Hold Output according to the setting of SW- of the module. or the extension module other than RC-DA, RC-DCx or RC-DCE The extension module is set to Hold Output by factory default setting. The PC Configurator software is used to change the setting to Reset Output. RC SPECIICATIS ES- Rev. Page /

13 MODEL: RC CNECTING THE EXTENSI MODULE ) Remove the extension connector cover located at the side of the basic module. ) Connect the extension module. ) Mount the combined module on a DIN rail. DIMENSIS unit: mm (inch) BASIC MODULE (.) (.) (.) (.). (.) DIN RAIL mm wide (.) (.) [ (.)]. (.) M SCREW TERMINALS for CC-Link, POWER (.) (.) M SCREW TERMINALS for I/O RC-TS (.) (.) (.) DIN RAIL mm wide (.) [ (.)] RC SPECIICATIS ES- Rev. Page /

14 MODEL: RC BASIC MODULE, ANALOG OUTPUT, RC-RR (.) (.) (.). (.) DIN RAIL mm wide (.) (.). (.) (.) (.) (.) [ (.)] M SCREW TERMINALS for CC-Link, POWER M SCREW TERMINALS for OUTPUT EXTENSI MODULE (RC-EA, RC-ECA, RC-ECB). (.) (.) (.) (.) (.). (.) DIN RAIL mm wide (.). (.) (.) M SCREW TERMINALS for I/O (.) [ (.)] EXTENSI MODULE (RC-EA, RC-ECA, RC-ECB, RC-ECC). (.) (.) (.) (.). (.) (.) (.). (.) (.) M SCREW TERMINALS for I/O (.) [ (.)] DIN RAIL mm wide RC SPECIICATIS ES- Rev. Page /

15 MODEL: RC DISCRETE INPUT MODULE, points MODEL: RC-DA SPECIICATIS Common: Positive or negative common (PNP/NPN) per points Number of I/O: Input, points Maximum inputs applicable at once: No limit (at V DC) Input status indicator: LED turns with contact Isolation: Input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote I/O Data allocation: Rated input voltage: V DC ± %; ripple %p-p max. voltage / current: V DC (input COM) /. ma voltage / current: V DC (input COM) / ma Input current:. ma per point at V DC Input resistance: Approx.. kω delay:. msec. delay:. msec. TERMINAL ASSIGNMENTS COM X X COM X X X X X X X X XA XB XC XD XE X NO. ID UTI NO. ID UTI COM Common COM Common X Input X Input X Input X Input X Input X Input X Input X Input X Input X Input XA Input XB Input XC Input XD Input XE Input X Input OPERATING MODE SETTING (*) actory setting Caution! - SW-, -, - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication Reset the output (turned off) Hold the output (*) (maintains the last data received normally) Extension (SW-, -, -, -) SW- SW- SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points RC SPECIICATIS ES- Rev. Page /

16 MODEL: RC CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. COM Input DA COM DB X Comm. DG X SLD X X V DC X V XA XC XE X X X EXTENSI CNECTOR X X XB XD X Input COM COM X X Input Connection Examples PNP Connection NPN Connection + COM COM COM COM X X X X RC SPECIICATIS ES- Rev. Page /

17 MODEL: RC NPN TRANSISTOR OUTPUT MODULE, points MODEL: RC-DCA SPECIICATIS Common: Negative common (NPN) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote I/O Data allocation: Rated load voltage: V DC ± % Rated output current:. A per point,. A per common Residual voltage:. V Leakage current:. ma delay:. msec. delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. DA DB DG SLD V DC V EXTENSI CNECTOR Comm. Output +V Y Y Y Y Y YA YC YE Y Y Y Y Y OPERATING MODE SETTING (*) actory setting Caution! - SW-, -, - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication Reset the output (turned off) Hold the output (*) (maintains the last data received normally) Extension (SW-, -, -, -) SW- SW- SW- SW- Extension No extension (*) Discrete output, or points TERMINAL ASSIGNMENTS + V Y Y V Y Y Y Y Y Y Y Y YA YB YC YD YE Y NO. ID UTI NO. ID UTI V V (common) + V V DC Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output YA Output YB Output YC Output YD Output YE Output Y Output Output Output Connection Example +V V Y Y + YB YD Y V +V Y Y V RC SPECIICATIS ES- Rev. Page /

18 MODEL: RC PNP TRANSISTOR OUTPUT MODULE, points MODEL: RC-DCB SPECIICATIS Common: Positive common (PNP) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote I/O Data allocation: Rated load voltage: V DC ± % Rated output current:. A per point,. A per common Residual voltage:. V Leakage current:. ma delay:. msec. delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) OPERATING MODE SETTING (*) actory setting Caution! - SW-, -, - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication Reset the output (turned off) Hold the output (*) (maintains the last data received normally) CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. DA DB DG SLD V DC V EXTENSI CNECTOR Output Comm. Output +V Y Y Y YA YC YE Y Y Y Y Y YB YD Y Y Y V +V Extension (SW-, -, -, -) SW- SW- SW- SW- Extension No extension (*) Discrete output, or points Y TERMINAL ASSIGNMENTS + V Y Y V Y Y Y Y Y Y Y Y YA YB YC YD YE Y Y V NO. ID UTI NO. ID UTI V V + V V DC (common) Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output YA Output YB Output YC Output YD Output YE Output Y Output Output Connection Example +V V Y Y RC SPECIICATIS ES- Rev. Page /

19 MODEL: RC RELAY CTACT OUTPUT MODULE, points MODEL: RC-DCC SPECIICATIS Common: common per points ( terminals) Common current: Max. A ( terminals) Number of I/O: Relay contact output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote I/O Data allocation: Relay driving power: V DC ± %, ma Rated load: V A (cos ø = ) V A (resistive load) Electrical life cycles (rate /min.) *When it is used as a product relevant to EU directive, it should be used under the Installation Category I, V AC or less. Maximum switching voltage: V AC or V DC Maximum switching power: VA or W Minimum load: V ma Mechanical life: cycles (rate /min.) When driving an inductive load, external contact protection and noise quenching are recommended. delay: msec. delay: msec. TERMINAL ASSIGNMENTS + V Y V Y Y Y Y COM Y COM Y COM Y COM NO. ID UTI NO. ID UTI V V + V V DC Common Y Output Common Y Output Common Y Output Common Y Output COM Common Y Output COM Common Y Output COM Common Y Output COM Common Y Output OPERATING MODE SETTING (*) actory setting Caution! - SW- through -, - through - are unused. Be sure to turn off the unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication Reset the output (turned off) Hold the output (*) (maintains the last data received normally) RC SPECIICATIS ES- Rev. Page /

20 MODEL: RC CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. DA DB DG SLD V DC V Comm. Y Y Y Y Y Y Y Y COM COM COM COM V +V Output Connection Example points / common points / common +V V DC +V V DC + V V Y Y Y Y Y Y Y COM COM Y COM COM RC SPECIICATIS ES- Rev. Page /

21 MODEL: RC RELAY CTACT OUTPUT MODULE, points MODEL: RC-DCE SPECIICATIS Common: common per points ( terminals) Common current: Max. A ( terminals) Number of I/O: Relay contact output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote I/O Data allocation: Relay driving power: V DC ± %, ma Rated load: V A (cos ø = ) V A (resistive load) Electrical life cycles (rate /min.) Maximum switching voltage: V AC or V DC Maximum switching power: VA or W Minimum load: V ma Mechanical life: cycles (rate /min.) When driving an inductive load, external contact protection and noise quenching are recommended. delay: msec. delay: msec. TERMINAL ASSIGNMENTS + V Y V Y Y Y Y COM Y COM Y COM Y COM NO. ID UTI NO. ID UTI V V + V V DC Common Y Output Common Y Output Common Y Output Common Y Output COM Common Y Output COM Common Y Output COM Common Y Output COM Common Y Output OPERATING MODE SETTING (*) actory setting Caution! - SW-, -, - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication Reset the output (turned off) Hold the output (*) (maintains the last data received normally) Extension (SW-, -, -, -) SW- SW- SW- SW- Extension No extension (*) Discrete output, or points RC SPECIICATIS ES- Rev. Page /

22 MODEL: RC CIRCUIT DIAGRAM Caution: terminal is NOT a protective conductor terminal. DA DB DG SLD V DC V Comm. Y Y Y Y EXTENSI CNECTOR Y Y Y Y COM COM COM COM V +V Output Connection Example points / common points / common +V V DC +V V DC + V V Y Y Y Y Y Y Y COM COM Y COM COM RC SPECIICATIS ES- Rev. Page /

23 MODEL: RC REMOTE CTROL RELAY CTROL MODULE MODEL: RC-RR RECOMMENDED PRODUCTS (OPERATI CHECKED) Remote control relay: BR-D, BR-D (Mitsubishi Electric) WR (Panasonic) Remote control transformer: BRT-B, BRT-B (Mitsubishi Electric) WR (Panasonic) SPECIICATIS Common: common per points ( terminals) Number of I/O: Output, points Maximum outputs applicable at once: No limit I/O status indicator: eedback input status turns on with the input supplied. Output status LED turns on with the output. Isolation: Output to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote I/O Data allocation: Rated load voltage: V AC ± % (supplied by the remote control transformer) Load voltage frequency: / Hz OPERATING MODE SETTING Each output is set with bits. Output setting is explained on the table below. NO. BIT SETTING UTI, No operation Output,, Output, Output, Invalid, No operation Output,, Output, Output, Invalid, No operation Output,, Output, Output, Invalid, No operation Output,, Output, Output, Invalid Do not set both bits. If the bits are simultaneously, the module will not operate normally. or repeating the output of pulse, after setting (, ), set (, ) once again. TERMINAL ASSIGNMENTS Y Y Y Y C C C C NO. ID UTI NO. ID UTI No connection No connection C Common Y Output C Common Y Output C Common Y Output C Common Y Output CIRCUIT DIAGRAM Caution: terminal is NOT a protective conductor terminal. DA DB DG SLD U(+) V( ) Y C Y C Com. Output Connection Example blue white red blue red blue Output Remote Transformer Remote Relay Remote Relay Y C Y C Y C Y C RC SPECIICATIS ES- Rev. Page /

24 MODEL: RC DC VOLTAGE/CURRENT INPUT MODULE, points MODEL: RC-SV SPECIICATIS Isolation: Input to input to input to input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: of the input range Input range Wide span voltage: - + V DC, - + V DC, V DC, V DC, V DC Narrow span voltage: - + V DC, V DC, V DC Current range: - + ma DC, ma DC, ma DC Input resistance Wide span voltage: MΩ Narrow span voltage: kω Current range: Ω Conversion rate / conversion accuracy: msec./±. %, msec./±. %, msec./±. %, msec./±. % Response time: Conversion rate + msec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points TERMINAL ASSIGNMENTS VH VL I VH VL I COM VH VL I COM VH VL I COM NO. ID UTI NO. ID UTI VH Wide span volt. VL Narrow span volt. Common I Current range VH Wide span volt. VL Narrow span volt. COM Common I Current range No connection No connection VH Wide span volt. VL Narrow span volt. COM Common I Current range VH Wide span volt. VL Narrow span volt. COM Common I Current range OPERATING MODE SETTING (*) actory setting Input Range (SW-, -, -, -) SW- SW- SW- SW- Input range - + V DC (*) - + V DC - + V DC V DC V DC V DC V DC V DC - + ma DC ma DC ma DC PC Configurator setting Conversion Rate / Accuracy (SW-, -) SW- SW- Conversion rate / Accuracy msec. / ±.% (*) msec. / ±.% msec. / ±.% msec. / ±.% RC SPECIICATIS ES- Rev. Page /

25 MODEL: RC CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT VH Input DA VL I Comm. DB DG SLD INPUT VH VL I Input V DC V COM INPUT VH VL I COM Input EXTENSI CNECTOR INPUT VH Input VL I COM Input Connection Examples + VHn VHn VHn WIDE SPAN VOLTAGE VLn In + NARROW SPAN VOLTAGE VLn In CURRENT RANGE + VLn In COMn COMn COMn Be sure to close across VLn and In terminals for a current input. RC SPECIICATIS ES- Rev. Page /

26 MODEL: RC THERMOCOUPLE INPUT MODULE, points MODEL: RC-TS SPECIICATIS Isolation: Input to input to input to input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: Engineering unit value ( C, K) (integer); No multiplication for Linearization: Standard Thermocouple: K, E, J, T, B, R, S, C, N, U, L, P, PR Cold junction compensation: CJC sensor attached to the input terminals Input resistance: kω Burnout sensing:. μa Conversion accuracy: ± C (±. ); ±. C (±. ) for B, R, S, C, PR Conversion rate: msec. or msec. Response time: Conversion rate + msec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) of max. span CJC error: ±. C at C ± C (±. at ± ) ±. C (±. ) for R, S, PR T/C BURNOUT INDICATI ( C) Downscale Upscale CORMAE RANGE ( C) K (CA) to + E (CRC) to + J (IC) to + T (CC) to + B (RH) to R - + to S - + to C (WRe -) - + to N to + U to + L to + P (Platinel II) - + to (PR) - + to BURNOUT T/C CORMAE INDICATI ( ) RANGE ( ) Downscale Upscale K (CA) to + E (CRC) to + J (IC) to + T (CC) to + B (RH) to R - + to S - + to C (WRe -) - + to N to + U to + L to + P (Platinel II) - + to (PR) - + to OPERATING MODE SETTING (*) actory setting Thermocouple Type (SW-, -, -, -) SW- SW- SW- SW- Thermocouple type K (CA) (*) E (CRC) J (IC) T (CC) B (RH) R S C (WRe -) N U L P (Platinel II) (PR) PC Configurator setting Conversion Rate (SW-) SW- Conversion rate msec. (*) msec. Burnout (SW-) SW- Burnout Upscale (*) Downscale Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points TERMINAL ASSIGNMENTS +IN IN +IN CJ +CJ +CJ IN CJ +IN IN CJ +CJ +IN +CJ CJ IN NO. ID UTI NO. ID UTI +CJ CJC + +IN T/C + CJ CJC IN T/C +CJ CJC + +IN T/C + CJ CJC IN T/C No connection No connection +CJ CJC + +IN T/C + CJ CJC IN T/C +CJ CJC + +IN T/C + CJ CJC IN T/C RC SPECIICATIS ES- Rev. Page /

27 MODEL: RC CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT +IN Input DA IN +CJ Comm. DB DG CJ SLD INPUT +IN IN +CJ Input V DC V CJ INPUT +IN IN +CJ CJ Input EXTENSI CNECTOR INPUT +IN Input IN +CJ CJ Input Connection Example T/C + CJC SENSOR +INn INn +CJn CJn RC SPECIICATIS ES- Rev. Page /

28 MODEL: RC RTD INPUT MODULE, points MODEL: RC-RS SPECIICATIS Isolation: Input to input to input to input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: Engineering unit value ( C, K) (integer); No multiplication for Linearization: Standard RTD: Pt (JIS, IEC), Pt (JIS ), JPt (JIS ), Pt Ω (JIS ), Ni, Cu, Cu Sensing current: ma Input resistance: MΩ Maximum leadwire resistance: Ω per wire Conversion accuracy: ± C (±. ); ± C (±. ) for Cu Conversion rate: msec. or msec. Response time: Conversion rate + msec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) of max. span RTD BURNOUT INDICATI ( C) CORMAE Downscale Upscale RANGE ( C) Pt (JIS, IEC) to + Pt (JIS ) to + JPt (JIS ) to + Pt Ω (JIS ) to + Ni to + C to + Cu to + RTD BURNOUT INDICATI ( ) CORMAE Downscale Upscale RANGE ( ) Pt (JIS, IEC) to + Pt (JIS ) to + JPt (JIS ) to + Pt Ω (JIS ) to + Ni to + C to + Cu to + OPERATING MODE SETTING (*) actory setting RTD Type (SW-, -, -, -) SW- SW- SW- SW- RTD Type Pt (JIS, IEC) (*) Pt (JIS ) JPt (JIS ) Pt Ω (JIS ) Ni C Cu PC Configurator setting Conversion Rate (SW-) SW- Conversion rate msec. (*) msec. Burnout (SW-) SW- Burnout Upscale (*) Downscale Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points TERMINAL ASSIGNMENTS INA INb INA INB INb INB INA INb INB INA INB INb NO. ID UTI NO. ID UTI No connection INA RTD -A INB RTD -B INb RTD -b No connection INA RTD -A INB RTD -B INb RTD -b No connection No connection No connection INA RTD -A INB RTD -B INb RTD -b No connection INA RTD -A INB RTD -B INb RTD -b RC SPECIICATIS ES- Rev. Page /

29 MODEL: RC CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT INA Input DA INB INb INPUT INA INB INb INPUT INA Input Input Comm. DB DG SLD V DC V INB INb INPUT INA INB INb Input EXTENSI CNECTOR Input Connection Example RTD A B B INAn INBn INbn RC SPECIICATIS ES- Rev. Page /

30 MODEL: RC THERMISTOR INPUT MODULE, points MODEL: RC-RTA SPECIICATIS Isolation: Input to input to input to input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: Engineering unit value ( C, K) (integer); No multiplication for Thermistor: AT-/AT- (SEMITEC Corporation) Excitation: Approx.. V DC (sensing resistance. kω) Input resistance: MΩ Burnout response time: sec. Conversion accuracy: ±. C (±. ) Conversion rate: msec. or msec. Response time: Conversion rate + msec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) THERMISTOR AT- AT- ( C) ( ) BURNOUT INDICATI Downscale - - Upscale + + CORMAE RANGE - to + - to + TERMINAL ASSIGNMENTS INA INB INA INB INA INB INA INB NO. ID UTI NO. ID UTI No connection INA Thermistor -A INB Thermistor -B No connection No connection INA Thermistor -A INB Thermistor -B No connection No connection No connection No connection INA Thermistor -A INB Thermistor -B No connection No connection INA Thermistor -A INB Thermistor -B No connection CIRCUIT DIAGRAM Caution: terminal is NOT a protective conductor terminal. INPUT INA INB INPUT INA Input Input Comm. DA DB DG SLD OPERATING MODE SETTING (*) actory setting Caution! - SW-, -, -, - are unused. Be sure to turn off unused ones. Conversion Rate (SW-) SW- Conversion rate msec. (*) msec. INB INPUT INA INB INPUT INA INB Input Input EXTENSI CNECTOR V DC V Burnout (SW-) SW- Burnout Upscale (*) Downscale Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points Input Connection Example Thermistor A INAn B INBn RC SPECIICATIS ES- Rev. Page /

31 MODEL: RC POTENTIOMETER INPUT MODULE, points MODEL: RC-MS SPECIICATIS Isolation: Input to input to input to input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: of the input range Potentiometer: Total resistance Ω kω Minimum span: % of total resistance Excitation: Approx.. V DC Conversion rate / conversion accuracy: msec./±. %, msec./±. %, msec./±. %, msec./±. % Response time: Conversion rate + msec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) OPERATING MODE SETTING (*) actory setting Caution! - SW-, -, -, - are unused. Be sure to turn off unused ones. Conversion Rate / Accuracy (SW-, -) SW- SW- Conversion rate / Accuracy msec. / ±.% (*) msec. / ±.% msec. / ±.% msec. / ±.% Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT H S L INPUT H S L INPUT H S L INPUT H S L Exc. Exc. Exc. Exc. Hn Input Input Input Input Input Connection Example POTENTIOMETER max. + min. Sn Ln Comm. EXTENSI CNECTOR DA DB DG SLD V DC V TERMINAL ASSIGNMENTS H L S H L S H L S H L S NO. ID UTI NO. ID UTI No connection H Pot H L Pot L S Pot S No connection H Pot H L Pot L S Pot S No connection No connection No connection H Pot H L Pot L S Pot S No connection H Pot H L Pot L S Pot S RC SPECIICATIS ES- Rev. Page /

32 MODEL: RC AC CURRENT INPUT MODULE, points (clamp-on current sensor CLSE use) MODEL: RC-CTE Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points SPECIICATIS Isolation: Input to input to input to input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: Engineering unit value (A) (Integer) (Engineering unit value (A) (Integer) for CLSE-R) Input range (Optional) CLSE-R: A AC CLSE-: A AC CLSE-: A AC CLSE-: A AC CLSE-: A AC CLSE-: A AC requency: / Hz Overload capacity: % continuous Operational range: % of rating (Operational range for the CLSE- is limited up to approx. % ().) (Note: Use for the circuit not exceed V) Conversion rate / conversion accuracy: msec./±. %, msec./±. %, msec./±. %, msec./±. % (The conversion accuracy does not include the accuracy of the sensor.) Response time:. sec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) OPERATING MODE SETTING (*) actory setting Input Range (SW-, -, -, -) SW- SW- SW- SW- Input range CLSE- (*) CLSE- CLSE- CLSE- CLSE- CLSE-R PC Configurator setting Conversion Rate / Accuracy (SW-, -) SW- SW- Conversion rate / Accuracy msec. / ±.% (*) msec. / ±.% msec. / ±.% msec. / ±.% TERMINAL ASSIGNMENTS K L K L K L K L NO. ID UTI NO. ID UTI No connection K AC current K No connection L AC current L No connection K AC current K No connection L AC current L No connection No connection No connection K AC current K No connection L AC current L No connection K AC current K No connection L AC current L CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. INPUT K L INPUT K L INPUT K L INPUT K L Input Input Input Input Connection Example SOURCE LOAD k l CLAMP- SENSOR Input Kn Ln Comm. DA DB DG SLD V DC V EXTENSI CNECTOR RC SPECIICATIS ES- Rev. Page /

33 MODEL: RC TOTALIZED PULSE INPUT MODULE, points MODEL: RC-PA SPECIICATIS Common: Positive or negative common (NPN/PNP) per points Number of I/O: Input, points Pulse Input status indicator: LED turns with contact Isolation: Input to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: or External excitation (PNP, NPN input) Sensing voltage: V DC ± %; ripple %p-p max voltage / current: V DC (input terminal - Cx) /. ma voltage / current: V DC (input terminal - Cx) / ma Voltage pulse input voltage / current: V DC (input terminal - Cx) /. ma voltage / current: V DC (input terminal - Cx) / ma Input current:. ma per point at V DC Input resistance: Approx.. kω delay:. msec. delay:. msec. Max. requency: Hz (This unit is designed to be able to accept a frequency up to Hz, however, chattering contact must be avoided for accurate measuring of such high frequency. Use relays that do not cause any chattering.) Minimum / pulse requirements: ms Accumulated pulse count: - Max. accumulated pulse count: - (actory default: ) Overflow: or (actory default: ) Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points TERMINAL ASSIGNMENTS V PI PI PI PI PI PI PI PI V C C C C C C C C NO. ID UTI NO. ID UTI V Power ( ) V + Power (+) C Common PI Input C Common PI Input C Common PI Input C Common PI Input C Common PI Input C Common PI Input C Common PI Input C Common PI Input OPERATING MODE SETTING (*) actory setting Caution! - SW- through SW- are unused. Be sure to turn off unused ones. Data Allocation (SW-) SW-D Data allocation (*) RC SPECIICATIS ES- Rev. Page /

34 MODEL: RC CIRCUIT DIAGRAM Caution: terminal is NOT a protective conductor terminal. V+ Input DA V DB PI PI Comm. DG SLD PI PI U (+) PI V ( ) PI PI PI C C C C C C C C EXTENSI CNECTOR Input V+ V PI C PI C Input Connection Examples PNP connection + V+ V NPN connection + V+ V Voltage Pulse Input V+ Connected V PI PI + PI C C C PI PI + PI C C C RC SPECIICATIS ES- Rev. Page /

35 MODEL: RC DC VOLTAGE OUTPUT MODULE, points MODEL: RC-YV SPECIICATIS Isolation: Output to output to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: of the output range Output range Wide span voltage: - + V DC, - + V DC, V DC, V DC, V DC Narrow span voltage: - + V DC, V DC, V DC Operational range: V DC or - + % Load resistance: kω Conversion accuracy: ±. % Response time: msec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) OPERATING MODE SETTING (*) actory setting Caution! - SW- is unused. Be sure to turn off unused ones. Output Range (SW-, -, -, -) SW- SW- SW- SW- Output range - + V DC (*) - + V DC - + V DC V DC V DC V DC V DC V DC PC Configurator setting TERMINAL ASSIGNMENTS VH VL VH COM VL COM NO. ID UTI NO. ID UTI No connection No connection Common VH Wide span volt. Common VL Narrow span volt. COM Common VH Wide span volt. COM Common VL Narrow span volt. CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. DA DB DG SLD V DC V EXTENSI CNECTOR Comm. Output Connection Examples VHn + Output Output VHn OUTPUT VH VL OUTPUT VH VL COM COM Output at the Loss of Communication (SW-) SW- Output at the loss of communication Reset the output (to -% or approx. -.V DC) Hold the output (*) (maintains the last data received normally) VLn COMn WIDE SPAN VOLTAGE VLn + NARROW SPAN VOLTAGE COMn Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points RC SPECIICATIS ES- Rev. Page /

36 MODEL: RC DC CURRENT OUTPUT MODULE, points MODEL: RC-YS SPECIICATIS Isolation: Output to output to power input to CC-Link or CC-Link: Conforms to Version. Station type: Remote device Data allocation: Converted data range: of the output range Output range: ma DC Load resistance: Ω Conversion accuracy: ±. % Response time: msec. ( %) Temperature coefficient: ±. %/ C (±. %/ ) OPERATING MODE SETTING (*) actory setting Caution! - SW-, - through - are unused. Be sure to turn off unused ones. Output at the Loss of Communication (SW-) SW- Output at the loss of communication Reset the output (to -%) Hold the output (*) (maintains the last data received normally) CIRCUIT DIAGRAM Note: In order to improve EMC performance, bond the terminal to ground. Caution: terminal is NOT a protective conductor terminal. DA DB DG SLD V DC V EXTENSI CNECTOR Comm. Output Output OUTPUT I OUTPUT I COM Extension (SW-, -) SW- SW- Extension No extension (*) Discrete input, or points Discrete output, or points TERMINAL ASSIGNMENTS I I COM NO. ID UTI NO. ID UTI No connection No connection Common I Current No connection No connection COM Common I Current No connection No connection RC SPECIICATIS ES- Rev. Page /

37 MODEL: RC DISCRETE INPUT EXTENSI MODULE, points CIRCUIT DIAGRAM MODEL: RC-EA SPECIICATIS Common: Positive or negative common (NPN/PNP) per points Number of I/O: Input, points Maximum inputs applicable at once: No limit (at V DC) Input status indicator: LED turns with contact Isolation: Input to internal circuits Rated input voltage: V DC ± %; ripple %p-p max. voltage / current: V DC (input COM) /. ma voltage / current: V DC (input COM) / ma Input current:. ma per point at V DC Input resistance: Approx.. kω delay:. msec. delay:. msec. COM X X X X X X X X Input Input EXTENSI CNECTOR TERMINAL ASSIGNMENTS COM COM X X X X X X X X X NO. ID UTI NO. ID UTI COM Common No Connection X Input X Input X Input X Input X Input X Input X Input X Input X Input Connection Examples PNP Connection NPN Connection + COM COM X X X X RC SPECIICATIS ES- Rev. Page /

38 MODEL: RC DISCRETE INPUT EXTENSI MODULE, points CIRCUIT DIAGRAM MODEL: RC-EA SPECIICATIS Common: Positive or negative common (PNP/NPN) per points Number of I/O: Input, points Maximum inputs applicable at once: No limit (at V DC) Input status indicator: LED turns with contact Isolation: Input to internal circuits Rated input voltage: V DC ± %; ripple %p-p max. voltage / current: V DC (input COM) /. ma voltage / current: V DC (input COM) / ma Input current:. ma per point at V DC Input resistance: Approx.. kω delay:. msec. delay:. msec. COM X X X X X XA XC XE X X X X X Input EXTENSI CNECTOR TERMINAL ASSIGNMENTS COM X X X X X X X X X X XA XB XC XD XE X XB XD X NO. ID UTI NO. ID UTI COM Common No Connection X Input X Input X Input X Input X Input X Input X Input X Input X Input X Input XA Input XB Input XC Input XD Input XE Input X Input Input COM X X Input Connection Examples PNP Connection NPN Connection + COM + COM X X X X RC SPECIICATIS ES- Rev. Page /

39 MODEL: RC NPN TRANSISTOR OUTPUT EXTENSI MODULE, points CIRCUIT DIAGRAM MODEL: RC-ECA SPECIICATIS Common: Negative common (NPN) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to internal circuits Rated load voltage: V DC ± % Rated output current:. A per point,. A per common Residual voltage:. V Leakage current:. ma delay:. msec. delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) EXTENSI CNECTOR Output Output +V Y Y Y Y Y Y Y Y V TERMINAL ASSIGNMENTS +V Y + V Y Y V Y Y Y Y Y Y NO. ID UTI NO. ID UTI V V (common) + V V DC Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y V Output Connection Example +V V + Y Y RC SPECIICATIS ES- Rev. Page /

40 MODEL: RC NPN TRANSISTOR OUTPUT EXTENSI MODULE, points CIRCUIT DIAGRAM MODEL: RC-ECA SPECIICATIS Common: Negative common (NPN) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to internal circuits Rated load voltage: V DC ± % Rated output current:. A per point,. A per common Residual voltage:. V Leakage current:. ma delay:. msec. delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) EXTENSI CNECTOR Output +V Y Y Y Y Y YA YC YE Y Y Y Y Y TERMINAL ASSIGNMENTS YB + V Y Y V Y Y Y Y Y Y Y Y YA YB YC YD YE Y YD Y V NO. ID UTI NO. ID UTI V V (common) + V V DC Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output YA Output YB Output YC Output YD Output YE Output Y Output Output +V Y Y V Output Connection Example +V V + Y Y RC SPECIICATIS ES- Rev. Page /

41 MODEL: RC PNP TRANSISTOR OUTPUT EXTENSI MODULE, points CIRCUIT DIAGRAM MODEL: RC-ECB SPECIICATIS Common: Positive common (PNP) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to internal circuits Rated load voltage: V DC ± % Rated output current:. A per point,. A per common Residual voltage:. V Leakage current:. ma delay:. msec. delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) EXTENSI CNECTOR Output Output +V Y Y Y Y Y Y Y Y V TERMINAL ASSIGNMENTS +V + V Y Y V Y Y Y Y Y Y Y NO. ID UTI NO. ID UTI V V + V V DC (common) Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y V Output Connection Example +V + V Y Y RC SPECIICATIS ES- Rev. Page /

42 MODEL: RC PNP TRANSISTOR OUTPUT EXTENSI MODULE, points CIRCUIT DIAGRAM MODEL: RC-ECB SPECIICATIS Common: Positive common (PNP) per points Number of I/O: Output, points Maximum outputs applicable at once: No limit (at V DC) Output status indicator: LED turns with contact Isolation: Output to internal circuits Rated load voltage: V DC ± % Rated output current:. A per point,. A per common Residual voltage:. V Leakage current:. ma delay:. msec. delay:. msec. (When driving an inductive load, connect a diode in parallel with the load.) EXTENSI CNECTOR Output +V Y Y Y Y Y YA YC YE Y Y Y Y TERMINAL ASSIGNMENTS Y YB + V Y Y V Y Y Y Y Y Y Y Y YA YB YC YD YE Y YD Y V NO. ID UTI NO. ID UTI V V + V V DC (common) Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output Y Output YA Output YB Output YC Output YD Output YE Output Y Output Output +V Y Y V Output Connection Example +V + V Y Y RC SPECIICATIS ES- Rev. Page /

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2] MODEL: R-RS Remote I/O R Series INPUT MODULE (high accuracy, points, isolated). (.0) 0 (.) 0 (.) mm (inch) MODEL: R-RS[][] ORDERING INFORMTI Code number: R-RS[][] Specify a code from below for each []

More information

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration

More information

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step

More information

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal

More information

Status Indicator LED PWR LINK COL

Status Indicator LED PWR LINK COL INSTRUCTION MANUAL DC VOLTAGE/CURRENT INPUT MODULE, 4 points (Ethernet Modbus/TCP) MODEL RE-SV4 RE-SV4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you

More information

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value. Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable

More information

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III) MODEL: RGHML3 Remote I/O RGH Series MECHATROLINK I/O MODULE (MECHATROLINK-III) ( V open collector input) PAA: Encoder input (speed / position) point ( V open collector input) STYVS: Self-synch input, DC

More information

DISCRETE INPUT MODULE, 16 points

DISCRETE INPUT MODULE, 16 points INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary

More information

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of

More information

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in

More information

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: TC10EM. Temperature Controller TC10 Series Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

[3] MOUNTING DIRECTION

[3] MOUNTING DIRECTION Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1. MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs

More information

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation) Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

MODEL: MRP6. Final Control Elements

MODEL: MRP6. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided

More information

MODEL: RZMS-U9. PC Recorders RZMS Series

MODEL: RZMS-U9. PC Recorders RZMS Series s RZMS Series PC RECORDER (universal input, 12 points; isolated) Functions & Features Industrial recorder on PC 12-point universal inputs Channel-to-channel isolation Trigger input and alarm contact output

More information

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter

More information

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link)

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link) INSTRUCTION MANUAL MULTI POWER MONITORING UNIT (clamp-on current sensor CC-Link) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined

More information

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2] Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication

More information

MODEL: WL40MW1F. Wireless I/O WL40F Series

MODEL: WL40MW1F. Wireless I/O WL40F Series Wireless I/O WL40F Series WIRELESS GATEWAY (Modbus-RTU Transparent 900MHz Band Wireless Device (child device)) FUTIONS & ATURES This unit Incorporates 900MHz band wireless module. Works as a gateway between

More information

NPN TRANSISTOR OUTPUT MODULE

NPN TRANSISTOR OUTPUT MODULE INSTRUCTION MANUAL NPN TRANSISTOR OUTPUT MODULE (3 points, MECHATROLINK- I/II use) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

MODEL: DAST-20. Telemetering System

MODEL: DAST-20. Telemetering System MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance

More information

General Specifications

General Specifications General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O

More information

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: JB2. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

DIGITAL PROGRAM CONTROLLER

DIGITAL PROGRAM CONTROLLER KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program

More information

Resistance Temperature Device Conversion Module

Resistance Temperature Device Conversion Module No.SS2-2330-0350 (Rev. 1) SystempaK (Digital/Single Case) Resistance Temperature Device Conversion Module Model J-SRP 90/95 Introduction The Resistance Temperature Device (RTD) Conversion Module (J-SRP)

More information

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type; DeviceNet) Functions & Features Small-size control valve actuator Direct connection to DeviceNet capable PLC and other devices on the same

More information

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The

More information

MODEL: DLS. Telemetering System

MODEL: DLS. Telemetering System POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power

More information

R7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2

R7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2 INSTRUCTION MANUAL DC VOLTAGE OUTPUT MODULE, 2 points MODEL R7L-YV2 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you

More information

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback

More information

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

FC-33, DC SELECTABLE SIGNAL CONDITIONER

FC-33, DC SELECTABLE SIGNAL CONDITIONER FC-33, DC SELECTABLE SIGNAL CONDITIONER Description. The FC-33 is a DIN rail or side mount, selectable input/output signal conditioner with 1500VDC isolation between input and output, and 1500VDC isolation

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

MODEL: 48NDVD. Bargraph Indicators 48N Series

MODEL: 48NDVD. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter; with -wire transmitter excitation) Displays a process variable in graphic bargraph of ED segments in proportion to a -wire

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

MODEL: 48NDV. Bargraph Indicators 48N Series

MODEL: 48NDV. Bargraph Indicators 48N Series Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter) Functions & Features Displays a process variable in graphic bargraph of ED segments Clear -digit digital meter Provides

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

SHIMADEN PROGRAM CONTROLLER

SHIMADEN PROGRAM CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and

More information

JPQ2 PULSE ACCUMULATOR

JPQ2 PULSE ACCUMULATOR INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as

More information

DIGITAL INDICATOR CC-Link Interface CSD Instruction Manual

DIGITAL INDICATOR CC-Link Interface CSD Instruction Manual DIGITAL INDICATOR CC-Link Interface CSD-903-73 Instruction Manual EN294-1499D 1 2 Introduction Thank you very much for your purchasing Minebea s Digital Indicator, model CSD-903-73. This instruction manual

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal Bargraph Indicators 8N Series BARGRAP INDICATING AAR Functions & Features Displays a process variable in graphic bargraph of ED segments Provides max. alarm contact outputs ulti-color indicator IP front

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

RZUS-U9 PC RECORDER MODEL. PC Recorders RZUS Series. (universal input, 12 points; isolated; bus-powered USB) MODEL & SUFFIX CODE SELECTION

RZUS-U9 PC RECORDER MODEL. PC Recorders RZUS Series. (universal input, 12 points; isolated; bus-powered USB) MODEL & SUFFIX CODE SELECTION MODEL & SUFFIX CODE SELECTION s RZUS Series PC RECORDER (universal input, 12 points; isolated; bus-powered US) MODEL RZUS-U9 RZUSU9T/MSR MODEL PC INTERFCE Full Speed US 2.0 (Modbus connection via virtual

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

General Specifications

General Specifications General Specifications GS J0U0-0E Model MU Universal Temperature Converter (Free Range Type) General The MU is a plug-in type universal temperature converter that converts input signal (thermocouple, RTD

More information

VersaPoint I/O Module

VersaPoint I/O Module GFK-2012A March 2010 Module provides two-input channels for measuring signals from standard thermocouples. It supports thirteen different thermocouples types. In addition, it accepts linear voltage inputs

More information

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485) Module type High-speed Digital ler SRX SRX General Description The SRX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners DRLP Series U ±0.03% Accuracy (Typical) U ±0.01% Linearity U 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection U Wide Loop

More information

FA Wireless SS Terminals

FA Wireless SS Terminals FA Wireless SS Terminals WT30 Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment Wireless Slave Station equipped with I/O. Height of 90 mm and

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

VersaPoint I/O Module

VersaPoint I/O Module Module provides two-input channels for resistive temperature sensors. It supports platinum or nickel sensors according to the DIN standard and SAMA Directive. In addition, CU10, CU50, CU53, KTY81 and KTY84

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information

Vibration 10 Times in X,Y,Z IEC In Case of Continuous Vibration

Vibration 10 Times in X,Y,Z IEC In Case of Continuous Vibration FEATURES LED Display to Monitor Running Conditions PhotoCoupler Insulated Snapin Installation Terminal BlockType 4bit (/6,84) or 6bit (/65,55) Resolution 4 or 8 Channels Voltage or DESCRIPTION PLCAIOCMAD

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV

CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV General Specifications Analog Input (Specifications) Items Specification Standards Operating Temp. Storage Temp. Operating Humidity Storage Humidity Vibration

More information

General Specifications

General Specifications General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

SKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation

SKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation SKJ J939 CANBus Output Signal Linear Positi to 4 inches ( m) Compact Design Simple To Install User Adjustable Measuring Cable Orientati SPECIFICATIONS Stroke Range Optis 25 inches (6.4 m), 4 inches (.2

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information