1 Railway Group Standard Date July 1996 Lineside Signs Signatures removed from electronic version Submitted by Philip Wiltshire Nominated Responsible Manager Approved by Synopsis This standard defines signs conveying information to traincrew to ensure the safe working of trains. Philip Wiltshire Chairman, Train Control and Communications Subject Committee Approved by This document is the property of Railtrack PLC. It shall not be reproduced in whole or in part without the written permission of the Controller, Safety Standards. Michael Harwood Chairman, Operations Standards Subject Committee Authorised by M.H. Walter Controller, Safety Standards Published by Safety & Standards Directorate Railtrack PLC Fitzroy House, 355 Euston Road London NW1 3AG Copyright 1996 Railtrack PLC

2

3 This page is intentionally blank.

4

5 Railway Group Standard Lineside Signs Date July 1996 Page 1 of 40 Contents Section Description Page Part A Issue record 5 Responsibilities and distribution 5 Compliance 5 Health and Safety Responsibilities 5 Supply 5 Part B 1 Purpose 6 2 Scope 6 3 Definitions 6 4 General Principles Objective Requirements 6 5 Lineside Signs Automatic Warning System (AWS) Commencement of AWS Gap Termination of AWS Gap Commencement of Special AWS Working Termination of Special AWS Working Permanently Installed AWS, Cancelling Indicator Cab and Radio Signalling Commencement of Cab Signalling Termination of Cab Signalling Cab Signalling, Block Section Limit Marker Radio Electronic Token Block, Loop Clear Marker Signalling Instruction Boards Whistle Board Remote Ground Frame Marker Countdown Marker Signals White Diamond Sign White Diamond sign with T White Diamond sign with X Telephone Number Plate Signal Identification Plate Distant Signal Sign and Identification Plate Automatic Signal Sign and Identification Plate Semi Automatic Signal Sign and Identification Plate Intermediate Block Home Signal Sign and Identification Plate Alias Plate SPAD Indicator Sign and Identification Plate Points Indicator Sign Ground Position Light Signal Identification Plate 20 R A I L T R A C K 1

6 Railway Group Standards Date July 1996 Page 2 of 40 Withdrawn Document Lineside Signs 5.5 Telephones Signal Post Telephone Sign Lineside Telephone Sign Electrification Telephone Sign Other Telephone Signs Safety Warning Limited Clearance Sign Warning No Refuges Sign Radio Channel Cab Secure Radio (CSR), Radio Channel Change Marker National Radio Network (NRN), Radio Channel Change 24 Marker Radio Electronic Token Block (RETB), Radio Channel Change Marker Permissible Speed Permissible Speed Warning Indicator Permissible Speed Warning Indicator, Standard Differential 25 Speeds Permissible Speed Warning Indicator, Non Standard 26 Differential Speeds Permissible Speed Indicator Permissible Speed Indicator, Standard Differential Speeds Permissible Speed Indicator, Non Standard Differential Speeds Emergency and Temporary Speed Emergency Indicator Temporary Speed Restriction, Warning Board Temporary Speed Restriction, Warning Board with 29 Differential Speeds Temporary Speed Restriction, Repeater Warning Board Temporary Speed Restriction, Speed Indicator Temporary Speed Restriction, Speed Indicator with 30 Differential Speeds Temporary Speed Restriction, Termination Indicator Temporary Speed Restriction, Spate Indicator Temporary Speed Restriction AWS, Cancelling Indicator Level Crossing Speed Level Crossing, Warning Board Open Level Crossing, Combined Speed 32 Restriction / Whistle Board Automatic Level Crossing, Speed Restriction Board Automatic Level Crossing, Wrong Direction Speed 33 Restriction Board 5.11 Electrification Neutral Section Warning Board Neutral Section Indication Board Coasting Board Absolute Possessions Possession Protection Board Work Site Markers 35 2 R A I L T R A C K

7 Railway Group Standard Lineside Signs Date July 1996 Page 3 of Miscellaneous Gradient Signs Mile Posts Spring Catch Point Location Sign Junction or Location Identification Plate Tunnel or Viaduct Identification Plate Signalbox Identification Plate Car Stop Markers Sandite Markers 39 References 40 R A I L T R A C K 3

8 Railway Group Standards Date July 1996 Page 4 of 40 Withdrawn Document Lineside Signs This page is intentionally blank. 4 R A I L T R A C K

9 Railway Group Standard Lineside Signs Date July 1996 Page 5 of 40 Part A Issue record This standard will be updated when necessary by distribution of a complete replacement. Amended or additional parts of revised pages will be marked by a vertical black line in the adjacent margin. Issue Date Comments One August 1995 New Document. Two December 1995 Supersedes Issue One. Three July 1996 This standard supersedes SSP12 Signal Post Identification Signs. Responsibilities and distribution Compliance Health and Safety Responsibilities Supply Controlled copies of this standard shall be complied with by all personnel who are involved in planning and implementing alterations to signalling equipment. The provisions of this Railway Group Standard are mandatory and compliance is required for new or altered work commissioned after The Infrastructure Controller shall consider the need for retrospective implementation. In authorising this Standard Railtrack PLC makes no warranties, express or implied, that compliance with all or any of Railway Group Standards is sufficient on its own to ensure safe systems of work or operation. Each user is reminded of its own responsibilities to ensure health and safety at work and its individual duties under health and safety legislation. Controlled and uncontrolled copies of this standard may be obtained from The Catalogue Secretary, Railtrack Safety & Standards Directorate, Floor 2, Fitzroy House, 355 Euston Road, London, NW1 3AG. Telephone: Facsimile: or (BT) or (BT) R A I L T R A C K 5

10 Railway Group Standards Date July 1996 Page 6 of 40 Withdrawn Document Lineside Signs 1 Purpose 2 Scope 3 Definitions 4 General Principles Part B To define the signs conveying information to traincrew to ensure the safe working of trains. This standard sets out the principles for the use of lineside signs applicable to train working. Each sign is defined in the standard in terms of appearance, information conveyed, colours and where appropriate, the relationship with other infrastructure. Signs for the safety of staff on or near the line and for public information, are included when they may be associated with the working of trains. Readable The person intended to read the sign is able to interpret all the information displayed by text, shape, colour or symbols. A sign shall only be considered readable at a given point when viewed by persons meeting the eyesight requirements of section 4.2. The equipment approval process shall include confirmation of readability by a representative sample of such persons. Identifiable The person intended to read the sign is able to see the whole of the sign, identify the type and purpose of the sign and, having an adequate level of route knowledge, read sufficient of the information displayed to interpret the meaning of the sign. Visible The person intended to read the sign is able to see the whole of the sign. 4.1 Objective Signs which are required to be read and understood by a driver of a moving train shall generally be visible for at least 4 seconds and readable or identifiable from any route approaching the sign from which it is intended to be read. The driver shall have sufficient time to understand the information on the sign and also sufficient time to understand any other information in the vicinity. The Infrastructure Controller shall ensure that the design, construction and approval of lineside signs meets the objective of this standard. 4.2 Requirements shall take account of site conditions including the requirements of GC/RT5203. Where stated for specific types of sign, positioning shall also be subject to the requirements of GK/RT0037. of signs relative to signals shall ensure that conflicting or confusing information is not displayed. 6 R A I L T R A C K

11 Railway Group Standard Lineside Signs Date July 1996 Page 7 of 40 Signs shall be securely positioned to minimise damage or defacement whilst obtaining best sighting and to avoid being obscured by persons working on or near the line. They shall be positioned where possible to the left of the line to which they apply. Information regarding the application of signs may also appear in other standards. Fixing arrangement shall not degrade the information displayed. Signs defined in this standard are intended to be read by drivers meeting the eyesight requirements of Group Standard GO/RT Approval tests shall consider the likelihood of degradation of a sign when in service. Unless otherwise stated in this standard, the front of signs shall be retro reflective and/or illuminated during the hours of darkness. With the exception of black, reflective performance shall be no worse than that associated with Class 1 retro reflective material (as defined in BS 873 Part 6). Signs shall be as depicted in this standard and colours shall conform to GK/RT0005 and wherever possible be reflective. The back of signs shall be grey. The use of signs not included in this standard, or a sign with differing text shall be kept to a minimum. Signs for new or localised applications shall be approved by the Infrastructure Controller, who shall then ensure that the information to be conveyed is published in the appropriate Weekly Operating Notices and/or Periodical Operating Notices and subsequently in the Sectional Appendices. All such signs shall conform fully with GK/RT0005 in respect of the use of colours. Additionally, the purpose of the sign shall be reinforced by use of the following shapes, either for the sign itself or as a symbol contained within a rectangular sign: a circular sign or symbol shall normally be used to denote an instruction; alternatively, a red border shall be used as detailed in section 5.3.1; a triangular sign or symbol shall denote a warning (i.e. a hazard or an advance indication of an instruction beyond); a rectangular sign or symbol shall be used for the display of information. The information content of local signs shall be kept to a minimum to ensure that the objective of this standard (see section 4.1) is achieved. When infrastructure alterations are carried out obsolete signs shall not be perpetuated. The Infrastructure Controller shall consider the replacement of obsolete signs whenever suitable opportunities arise, for example resignalling or an alteration to a layout. The Infrastructure Controller shall ensure that signs are of a suitable size and construction to meet the requirements of this standard, taking into account the need for consistency and the avoidance of confusion to traincrew. The Infrastructure Controller shall ensure that the positioning of signs is documented and that the signs are inspected to confirm adequate cleanliness, visibility and readability. R A I L T R A C K 7

12 Railway Group Standards Date July 1996 Page 8 of 40 Withdrawn Document Lineside Signs 5 Lineside Signs AWS 5.1 Automatic Warning System (AWS) Refer to GK/RT0016 for further details of application Commencement of AWS Gap There is no AWS beyond the sign. The sign shall generally be affixed on a short post at the lineside Termination of AWS Gap The line(s) beyond the sign is/are equipped with AWS. AWS The sign shall generally be affixed on a short post at the lineside Commencement of Special AWS Working The sign informs that AWS equipment on the line beyond this sign and applicable to movements in the opposite direction has not been suppressed. Cancelling indicators are not provided. AWS The sign shall generally be affixed on a short post at the lineside. 8 R A I L T R A C K

13 Railway Group Standard Lineside Signs Date July 1996 Page 9 of Termination of Special AWS Working The sign informs that normal AWS working resumes beyond the sign. AWS The sign shall generally be affixed on a short post at the lineside Permanently Installed AWS, Cancelling Indicator The AWS indication already received shall be ignored. The sign shall generally be affixed on a short post at the lineside. R A I L T R A C K 9

14 Railway Group Standards Date July 1996 Page 10 of 40 Withdrawn Document Lineside Signs CAB 5.2 Cab and Radio Signalling For further details of cab signalling application refer to GK/RT Commencement of Cab Signalling The sign informs that the line ahead is equipped with Cab signalling and the driver must confirm that the Cab signalling equipment has been activated. The sign shall be positioned at the driver s eye level Termination of Cab Signalling The line ahead is not equipped with Cab signalling and the driver must ensure that the Cab signalling equipment has been disabled. CAB The sign shall be positioned at the driver s eye level Cab Signalling, Block Section Limit Marker This sign marks the limit of a block section on Cab signalled lines where lineside signals are not provided. Shall be positioned at driver s eye level. Each marker shall have an associated signal identification sign. The position of these signs shall be subject to signal sighting in accordance with GK/RT0037. Shall be identifiable at permissible speed. 10 R A I L T R A C K

15 Railway Group Standard Lineside Signs Date July 1996 Page 11 of Radio Electronic Token Block, Loop Clear Marker For further details of application refer to GK/RT0054. The train has cleared the previous token block section or station limits. 45 The sign shall be fixed as near as possible to driver s eye level. The positioning of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be identifiable at attainable speed from starting at the previous stop board. R A I L T R A C K 11

16 Railway Group Standards Date July 1996 Withdrawn Document Lineside Signs Page 12 of Signalling For further details refer to GK/RT0035. Stop Whistle before proceeding a) Electric locomotovies stop here b) Shut off engine while stationary at this signal c) Instruction Boards The sign provides the driver with instructions or information. a) red circular symbol denotes all trains stop. For further details refer to GK/RT0031 b) red border denotes a mandatory instruction c) black and white denotes information The sign shall be fixed as near as possible to driver s eye level. The sign shall be identifiable at permissible speed and also readable when stationary. Care shall be taken in determining the size of the sign and text Whistle Board The driver shall sound the horn, in accordance with the Rule Book. The sign shall be fixed as near as possible to driver s eye level. 12 R A I L T R A C K

17 Railway Group Standard Lineside Signs Date July 1996 Page 13 of Remote Ground Frame Marker For further details of application refer to GK/RT The stopping position on the approach to a remote ground frame. The sign shall be fixed as near as possible to driver s eye level. The positioning of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be visible at low speed, the driver having received a previous warning (generally by a distant signal) on the approach to the sign Countdown Marker The sign informs that the stopping position is a specific distance away. There are three signs: a) Outer Board b) Intermediate Board c) Inner Board a) b) 45 The sign shall be fixed as near as possible to driver s eye level and shall be positioned 300m, 200m, and 100m from the stopping position. The sign shall be identifiable at the approach speed to the stopping position. c) R A I L T R A C K 13

18 Railway Group Standards Date July 1996 Page 14 of 40 Withdrawn Document Lineside Signs 5.4 Signals White Diamond Sign For further details of application refer to GK/RT0035. No signal post telephone is provided but train detection or other means of protection is provided on the approach to the signal. The sign shall be affixed to the associated signal structure. The of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be readable when stationary at the signal White Diamond sign with T For further details of application refer to GK/RT0035. The signal post telephone is in a restricted clearance area and has call back facilities. The sign shall generally be affixed to the associated signal structure. The positioning of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be readable when stationary at the signal. 14 R A I L T R A C K

19 Railway Group Standard Lineside Signs Date July 1996 Page 15 of White Diamond sign with X For further details of application refer to GK/RT0035. Due to restricted clearances, the driver must only use the signal post telephone in an emergency or when advised that it is safe. The sign shall generally be affixed to the associated signal structure. The positioning of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be readable when stationary at the signal. Tel. No Telephone Number Plate This sign displays the signalman s telephone number. The sign shall generally be affixed immediately underneath the White Diamond Sign with X and as otherwise determined by the Infrastructure Controller. The sign shall be readable when stationary at the signal. R A I L T R A C K 15

20 Railway Group Standards Date July 1996 Page 16 of 40 Withdrawn Document Lineside Signs Signal Identification Plate For further details of application refer to GK/RT0009. The sign displays the signal identity. Suffixes BR and CA are for Banner Repeating and Co Acting signals respectively. The sign shall generally be affixed to the associated signal post or structure. BR CA 16 R A I L T R A C K

21 Railway Group Standard Lineside Signs Date July 1996 Page 17 of Distant Signal Sign and Identification Plate For further details of application refer to GK/RT0009. The sign displays the signal identity and indicates that the signal is not capable of displaying a stop aspect. The sign shall generally be affixed to the associated signal post or structure. R Automatic Signal Sign and Identification Plate For further details of application refer to GK/RT0009. The sign displays the signal identity and indicates that the rules applicable to automatic signals apply. The sign shall generally be affixed to the associated signal post or structure. R A I L T R A C K 17

22 Railway Group Standards Date July 1996 Page 18 of 40 Withdrawn Document Lineside Signs SEMI Semi Automatic Signal Sign and Identification Plate For further details of application refer to GK/RT0009. The sign displays the signal identity and indicates that the rules applicable to semi automatic signals apply. The sign shall generally be affixed to the associated signal post or structure Intermediate Block Home Signal Sign and Identification Plate For further details of application refer to GK/RT0009. A The sign displays the signal identity and indicates that the rules applicable to intermediate block home signals apply. The sign shall generally be affixed to the associated signal post or structure. 18 R A I L T R A C K

23 Railway Group Standard Lineside Signs Date July 1996 Page 19 of 40 ) Alias Plate For further details of application refer to GK/RT0009. For cab secure radio purposes the radio identification number, which is different from the signal identification, is as shown. The sign shall generally be affixed immediately underneath the Signal Identification Plate at locations where radio set up is required The sign shall be readable when stationary at locations where a driver is required to set up the radio. SPAD INDICATOR SPAD Indicator Sign and Identification Plate For further details of application refer to GK/RT0009. The sign identifies a SPAD indicator and displays its identity. The driver shall disregard the indicator if not lit. If lit, the driver must stop immediately. The sign shall generally be affixed to the associated signal post or structure. R A I L T R A C K 19

24 Railway Group Standards Date July 1996 Page 20 of 40 Withdrawn Document Lineside Signs Points Indicator Sign POINTS INDICATOR The sign identifies a points indicator. If yellow light not shown the driver must stop and not pass over the facing points until they have been secured. The sign shall generally be affixed to the associated signal post or structure Ground Position Light Signal Identification Plate For further details of application refer to GK/RT0009. The arrow shall be provided where necessary to indicate the line to which the signal applies. This sign enables the associated signal to be accurately identified and where an arrow is displayed identifies the line to which a ground Position Light Signal applies. The sign shall be mounted immediately above or below the associated Ground Position Light Signal. The sign shall be identifiable at low speed or whilst stationary at the signal. 20 R A I L T R A C K

25 Railway Group Standard Lineside Signs Date July 1996 Page 21 of Telephones Signal Post Telephone Sign For further details of application refer to GK/RT0035. a) b) This sign identifies a signal post telephone communicating directly with the signalman. a) Initial contact to be made within two minutes. b) Initial contact to be made within the number of minutes indicated. On the telephone cabinet. If the telephone cabinet is not obvious when stationary at the signal, signs a), b) or shall additionally be affixed to the signal post or structure. The sign shall be identifiable when stationary at the signal Lineside Telephone Sign The sign identifies the position of a lineside telephone other than a signal post telephone communicating directly with the signalman. Generally on the telephone cabinet, and the cabinet should be in a position of safety. The sign shall be identifiable when stationary or within the vicinity of the sign. R A I L T R A C K 21

26 Railway Group Standards Date July 1996 Page 22 of 40 Withdrawn Document Lineside Signs Electrification Telephone Sign The telephone communicates directly with the electrical control operator. Electrification Generally on the telephone cabinet, and the cabinet should be in a position of safety. The sign shall be identifiable when stationary or within the vicinity of the sign Other Telephone Signs The sign identifies the position of a telephone for public or general use. Generally on the telephone cabinet, and the cabinet shall be in a position of safety. The sign shall be identifiable when stationary or within the vicinity of the sign. Note: The eyesight requirements of GO/RT3251 do not apply to these signs. Emergency telephone 22 R A I L T R A C K

27 Railway Group Standard Lineside Signs Date July 1996 Page 23 of Safety Warning Limited Clearance Sign The sign identifies where there is limited clearance where a train passes. Warning The sign shall be affixed at the lineside. Limited Clearance The sign shall be identifiable when stationary or within the vicinity of the sign. It is not necessary to provide lighting or retro reflective material. Warning Warning No Refuges Sign The sign identifies where there are no refuges and where adequate clearances or refuges exist only on the opposite side of the line. This applies only where permissible speeds exceed 100 mile/h. No Refuges The sign shall be affixed at the lineside. The sign shall be identifiable when stationary or within the vicinity of the sign. It is not necessary to provide lighting or retro reflective material. R A I L T R A C K 23

28 Railway Group Standards Date July 1996 Page 24 of 40 Withdrawn Document Lineside Signs 5.7 Radio Channel Cab Secure Radio (CSR), Radio Channel Change Marker The number of the CSR radio channel for the line ahead, to which the driver must ensure that his radio is tuned. The sign shall be fixed as near as possible to driver s eye level National Radio Network (NRN), Radio Channel Change Marker The sign informs of the NRN radio channel required to be used for the line ahead. The sign shall be fixed as near as possible to driver s eye level Radio Electronic Token Block (RETB), Radio Channel Change Marker B The sign informs of the RETB radio channel required to be used for the line ahead. The sign shall be fixed, as near as possible to driver s eye level. 24 R A I L T R A C K

29 Railway Group Standard Lineside Signs Date July 1996 Page 25 of Permissible Speed For further details of application refer to GK/RT0038. All figures quoted in miles/h. In special circumstances Km/h may be shown with white numerals on a black background Permissible Speed Warning Indicator The sign provides warning of a reduction of permissible speed ahead. The directional arrow when used indicates the permissible speed is over a diverging route. The sign shall be affixed at the lineside. The position of these signs shall be subject to signal sighting in accordance with GK/RT0037. The appropriate sign shall be used as above depending upon whether there are two or three numerals. Where there is limited clearance, a smaller indicator may be used Permissible Speed Warning Indicator, Standard Differential Speeds The sign provides warning of a reduction for a standard differential permissible speed ahead. The two sets of numerals represent two different speeds, each applicable to different classes of train. Instructions regarding the classification of trains for this purpose are in the rule book appendix. The sign shall generally be affixed at the lineside. The position of these signs shall be subject to signal sighting in accordance with GK/RT0037. Where there is limited clearance, a smaller sign may be used. R A I L T R A C K 25

30 Railway Group Standards Date July 1996 Page 26 of 40 Withdrawn Document Lineside Signs Permissible Speed Warning Indicator, Non Standard Differential Speeds This sign is applicable to certain types of train as indicated by the text (e.g. HST or DMU) and provides advance warning of a reduction for a non standard differential permissible speed ahead. The sign shall generally be affixed at the lineside. The position of these signs shall be subject to signal sighting in accordance with GK/RT0037. Where there is limited clearance, a smaller indicator may be used Permissible Speed Indicator The sign displays the commencement of a permissible speed shown. The directional arrow where provided indicates the speed is applicable over the diverging route (in the example, to the right). The sign shall generally be affixed at the lineside. The sign shall be readable at permissible speed. Where there is limited clearance, a smaller indicator may be used. 26 R A I L T R A C K

31 Railway Group Standard Lineside Signs Date July 1996 Page 27 of Permissible Speed Indicator, Standard Differential Speeds The sign displays the commencement of a standard differential permissible speed shown. Two sets of numerals are shown representing two different speeds, each applicable to different classes of train. Instructions regarding the classification of trains for this purpose are in the rule book appendix. The sign shall be affixed at the lineside. The sign shall be readable at permissible speed. Where there is limited clearance, the smaller indicator may be used Permissible Speed Indicator, Non Standard Differential Speeds This sign indicates the commencement of a permissible speed applicable to certain types of train as indicated by the text (e.g. HST or DMU) which permits non standard differential permissible speed ahead. The sign shall be affixed at the lineside. The sign shall be readable at permissible speed. Where there is limited clearance, the smaller indicator may be used. R A I L T R A C K 27

32 Railway Group Standards Date July 1996 Page 28 of 40 Withdrawn Document Lineside Signs 5.9 Emergency and Temporary Speed For further details of application refer to GK/RT0038. Refer to GC/RT5060 for details of construction. All figures quoted in miles/h Emergency Indicator The sign provides warning of an emergency speed restriction warning board ahead. The sign shall be positioned at ground level at the lineside Temporary Speed Restriction, Warning Board This board provides warning of a temporary speed restriction ahead. The directional arrow when used indicates the temporary speed is over a diverging route. The sign shall be positioned at the lineside. 28 R A I L T R A C K

33 Railway Group Standard Lineside Signs Date July 1996 Page 29 of Temporary Speed Restriction, Warning Board with Differential Speeds This board provides warning of a differential temporary speed restriction ahead. Two sets of numerals are shown representing two different speeds, each applicable to different classes of train. Instructions regarding the classification of trains for this purpose are in rule book appendix. The sign shall be positioned at the lineside Temporary Speed Restriction, Repeater Warning Board The sign shall remind drivers starting from a passenger station, siding connection or dead end platform line that there is a temporary speed restriction ahead. The sign shall be positioned at the lineside. The sign shall be identifiable at low speed and when stationary. R A I L T R A C K 29

34 Railway Group Standards Date July 1996 Page 30 of 40 Withdrawn Document Lineside Signs Temporary Speed Restriction, Speed Indicator The sign indicates the commencement of a temporary speed restriction shown. The directional arrow, where provided, indicates the speed is applicable over the diverging route (in the example, to the left). The sign shall generally be positioned at the lineside. The sign shall be readable at permissible speed Temporary Speed Restriction, Speed Indicator with Differential Speeds The sign states the values of the temporary speed restriction commencing at the sign. Instructions regarding the classification of trains for this purpose are in the rule book appendix. The sign shall generally be positioned at the lineside. The sign shall be readable at permissible speed Temporary Speed Restriction, Termination Indicator The sign identifies the end of a temporary speed restriction. The sign shall generally be positioned at the lineside. The sign shall be readable at permissible speed. 30 R A I L T R A C K

35 Railway Group Standard Lineside Signs Date July 1996 Page 31 of Temporary Speed Restriction, Spate Indicator The sign informs that a temporary speed restriction has either been withdrawn or not imposed. The sign shall generally be positioned at the lineside. The sign shall be readable at permissible speed Temporary Speed Restriction AWS, Cancelling Indicator The AWS indication already received shall be ignored. The sign shall generally be positioned at the lineside. The sign shall be readable at permissible speed. R A I L T R A C K 31

36 Railway Group Standards Date July 1996 Page 32 of 40 Withdrawn Document Lineside Signs 5.10 Level Crossing Speed For further details of application refer to GK/RT Level Crossing, Warning Board This sign is used at: Automatic Barrier Crossings, locally monitored. Automatic Open Crossings, locally monitored. Open Crossings. Traincrew Operated Crossings. The driver must regulate speed for the level crossing ahead. The sign shall be fixed as near as possible to driver s eye level. The positioning of these signs shall be subject to signal sighting in accordance with GK/RT Open Level Crossing, Combined Speed Restriction / Whistle Board The sign indicates the commencement of the permissible speed on the approach to an open crossing and that the horn shall be sounded. A single set of numerals represents a single speed which applies to all trains. When two sets of numerals are shown representing two different speeds, each speed shall be applicable to different classes of train. Instructions regarding the classification of trains for this purpose are in the rule book appendix. The sign shall be affixed at the lineside. The position of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be readable at permissible speed. 32 R A I L T R A C K

37 Railway Group Standard Lineside Signs Date July 1996 Page 33 of Automatic Level Crossing, Speed Restriction Board This sign is used at: Automatic Barrier Crossings, locally monitored. Automatic Open Crossings, locally monitored. The sign indicates the commencement of the permissible speed on the approach to a locally monitored automatic level crossing. It also indicates the point at which the driver is required to ensure that the level crossing is clear and to observe the driver s level crossing indicator. The sign shall generally be affixed at the lineside as near as possible to the driver s eye level. Boards to be provided on all approaches for which controls are provided. The position of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be readable at permissible speed Automatic Level Crossing, Wrong Direction Speed Restriction Board This sign is used at: Automatic Half Barrier Crossings Crossings with Miniature Warning Lights The sign states the value of the permitted speed between the sign and the level crossing for trains travelling in the wrong direction, where wrong direction controls are provided. The sign shall be affixed at the lineside generally to the right of the track. The position of these signs shall be subject to signal sighting in accordance with GK/RT0037. The sign shall be readable at an approach speed of up to 50 m.p.h. R A I L T R A C K 33

38 Railway Group Standards Date July 1996 Page 34 of 40 Withdrawn Document Lineside Signs 5.11 Electrification Neutral Section Warning Board The sign shall provide an advance warning of the approach to an electrification neutral section. The sign shall generally be affixed to an electrification structure at the lineside, approximately 1.6km in rear of the neutral section Neutral Section Indication Board The sign identifies the commencement of a neutral section. The sign shall generally be affixed to the first electrification structure at the lineside, located in rear of the neutral section Coasting Board The board advises the driver to coast to a stopping point or significant speed reduction beyond the board. The sign shall generally be affixed to a short post at the lineside. 34 R A I L T R A C K

39 Railway Group Standard Lineside Signs Date July 1996 Page 35 of Absolute Possessions Instructions for the use of these signs are contained in the rule book Possession Protection Board Identifies the boundary of an Absolute Possession The sign shall be double sided and shall be positioned on the line central to the detonator protection. The sign shall be identifiable at permissible speed Work Site Markers The board with red flashing lights identifies the entrance to a work site area. The board with yellow flashing lights identifies the exit from a work site area. The sign shall be double sided and shall be positioned at the lineside close to ground level. The sign shall be identifiable at low speed. R A I L T R A C K 35

40 Railway Group Standards Date July 1996 Page 36 of 40 Withdrawn Document Lineside Signs 5.13 Miscellaneous Gradient Signs The sign shall display the gradient of the track and its inclination either side of the sign. Where there is no gradient, Level shall be displayed. The sign shall generally be affixed at the lineside, parallel to the track, at a change of gradient. All signs shall be placed on a designated side of the line together with the mile posts. The sign shall be identifiable from a moving train and readable from a stationary train. It is not necessary to provide lighting or retro reflective material Mile Posts The mile posts shall display the distance from a datum point. Optionally, on ¼, ½ and ¾ mile posts, the mileage may also be shown. Fig. 1 The sign shall generally be affixed to short posts at the lineside parallel to the track. Signs shall be placed on a designated side of the line together with the gradient signs. Duplicate signs may be provided angled at 45 on a central post (as shown in fig.1). It is not necessary to provide lighting or retro reflective material. or or 36 R A I L T R A C K

41 Railway Group Standard Lineside Signs Date July 1996 Page 37 of Spring Catch Point Location Sign The sign identifies the position of spring catch points. The sign shall be double sided and shall be affixed at the lineside on the approach to the points in the facing direction. The sign shall be identifiable at low speed. Crossways Junction North Highfields Junction Junction or Location Identification Plate The sign displays the name of the junction or other geographical feature e.g. level crossing. The sign shall be affixed at the lineside. It is not necessary to provide lighting or retro reflective material Tunnel or Viaduct Identification Plate The sign displays the name and length (in yards) of the tunnel or viaduct. Totley Tunnel 6230 yards The sign shall be affixed at the tunnel mouth or commencement of viaduct. R A I L T R A C K 37

42 Railway Group Standards Date July 1996 Page 38 of 40 Withdrawn Document Lineside Signs Signalbox Identification Plate Manton Junction The sign displays the name of the signalbox to which it is attached. The sign or signs shall be affixed to the signalbox where it is visible to an approaching or passing train. It is not necessary to provide lighting or retro reflective material Car Stop Markers Additional wording or abbreviation may be used to indicate application to different types of train, for example S = all trains stop. 8 8 Car stop The sign shall be affixed at the point where the front of the train is required to stop. The notice displays the position where the train should stop for the respective total number of vehicles or type of train. Car stop The sign shall be identifiable at low speed. It is not necessary to provide lighting or retro reflective material. Car stop 38 R A I L T R A C K

43 Railway Group Standard Lineside Signs Date July 1996 Page 39 of Sandite Markers The signs inform of the location of low adhesion sites requiring sandite application. There are three signs: a) Advance Warning b) Commence Application c) Cease Application a) b) 45 The signs shall be positioned as near as possible to drivers eye level.. Visibility requirements The signs shall be identifiable at permissible speed. c) R A I L T R A C K 39

44 Railway Group Standards Date July 1996 Page 40 of 40 Withdrawn Document Lineside Signs References British Standard Railway Group Standards BS873 Road traffic signs and internally illuminated bollards Part 6. Specification for retro reflective and non retro reflective signs. GK/RT0005 GK/RT0009 GK/RT0016 GK/RT0031 GK/RT0035 GK/RT0036 GK/RT0037 GK/RT0038 GK/RT0054 GO/RT3251 GC/RT5060 GC/RT5203 Safety Related Colours for Signalling Application Nomenclature and Identification of Signalling Equipment Automatic Warning System Lineside Signals and Indicators Layout of Lineside Signals Transition Between Lineside and Other Signalling Systems Signal Sighting Speed Restrictions Radio Electronic Token Block Safety Requirements for Train Drivers Equipment for the Signing of Temporary and Emergency Speed Restrictions Infrastructure Requirements for Personal Safety in Respect of Clearances and Access. 40 R A I L T R A C K

Absolute Block. Uncontrolled When Printed Document to be part superseded by GKRT0055 Iss 1 and GKRT0077 Iss 1 (published on 07/09/2013)

Absolute Block. Uncontrolled When Printed Document to be part superseded by GKRT0055 Iss 1 and GKRT0077 Iss 1 (published on 07/09/2013) Signatures removed from electronic version Submitted by... Richard Genner Nominated Responsible Manager Approved by... Philip Wiltshire Chairman, Train Control & Communications Subject Committee Approved

More information

GK/GN0609. Guidance on Identification of Signalling and Related Equipment. Issue One June 2011 Rail Industry Guidance Note for GK/RT0009.

GK/GN0609. Guidance on Identification of Signalling and Related Equipment. Issue One June 2011 Rail Industry Guidance Note for GK/RT0009. GN Published by Block 2 Angel Square 1 Torrens Street London EC1V 1NY Copyright 2011 Rail Safety and Standards Board Limited GK/GN0609 Issue One June 2011 Rail Industry Guidance Note for GK/RT0009 Issue

More information

Signalling Layout and Signal Aspect Sequence Requirements

Signalling Layout and Signal Aspect Sequence Requirements Signalling Layout and Signal Aspect Sequence Requirements Synopsis This document sets out requirements for the lineside signalling system to be compatible with train operations and guidance on their application.

More information

GE/GN8648. Guidance on Positioning of Lineside Telephones. Rail Industry Guidance Note for GE/RT8048

GE/GN8648. Guidance on Positioning of Lineside Telephones. Rail Industry Guidance Note for GE/RT8048 GN This document contains one or more pages which contain colour. Published by: Block 2 Angel Square 1 Torrens Street London EC1V 1NY Copyright 2013 Rail Safety and Standards Board Limited GE/GN8648 Issue

More information

Requirements for GSM-R Voice Radio System

Requirements for GSM-R Voice Radio System Requirements for GSM-R Voice Radio System Signatures removed from electronic version Synopsis This document mandates requirements for the use of GSM-R systems, where these are available, to support operational

More information

Interlocking Principles

Interlocking Principles Date June 2003 Interlocking Principles Synopsis This document mandates the principles of interlocking of signals, points and other parts of the signalling system so that the safe operation of trains is

More information

Provision of Telephones at Level Crossings

Provision of Telephones at Level Crossings Provision of Telephones at Level Crossings Submitted by Synopsis This standard describes the requirements for the provision of telephone facilities at level crossings.... Jon Melmoth Nominated Responsible

More information

Stalybridge Remodelling and Resignalling Ashton Moss North Junction/Ashton Viaduct No.1 and Mossley

Stalybridge Remodelling and Resignalling Ashton Moss North Junction/Ashton Viaduct No.1 and Mossley GIOCONA Remodelling and Resignalling Ashton Moss North Junction/Ashton Viaduct No.1 and Mossley T.A.P.M.108.0.0.0.1.NW7021/NW21 Remodelling and Resignalling NW21/NW7021 Ashton Moss S.B./Ashton Viaduct

More information

Code of Practice : Preferred Value Testing Data

Code of Practice : Preferred Value Testing Data Code of Practice Issue One Date Dec 1997 Code of Practice : Preferred Value Testing Data Synopsis This Code of Practice gives preferred values for testing data for signalling works in support of GK/RT0221.

More information

Guidance Note: Signalling Control Centres

Guidance Note: Signalling Control Centres Guidance Note: Signalling Control Centres Synopsis This document provides guidance on meeting the requirements of Railway Group Standard GK/RT0025. Signatures removed from electronic version Submitted

More information

25kV A.C. Electrified Lines - Traction Bonding

25kV A.C. Electrified Lines - Traction Bonding Date:MAR 94 25kV A.C. Electrified Lines - Traction Page 1 of 6 Part A Synopsis This is issued by the to define the Boards requirements for continuity bonding on railway systems. This will ensure a continuous

More information

Signalling Maintenance Testing

Signalling Maintenance Testing Date Feb 1997 Signalling Maintenance Testing Signatures removed from electronic version Synopsis This standard defines the testing requirements for previously working and commissioned signalling systems

More information

BR930 Series Pin Code Allocations and Contact Arrangements

BR930 Series Pin Code Allocations and Contact Arrangements BR930 Series Pin Code Allocations and Contact Arrangements Synopsis This Guidence Note provides details of pin code allocations and contact arrangements f BR930 series equipment. Submitted by Nick Howland

More information

Train Radio Systems for Voice and Related Messaging Communications

Train Radio Systems for Voice and Related Messaging Communications Uncontrolled When Printed Railway Group Standard Train Radio Systems for Voice and Related Messaging Communications Synopsis This document mandates the minimum requirements for radio systems that provide

More information

Status Date Prepared Reviewed Endorsed Approved

Status Date Prepared Reviewed Endorsed Approved Discipline Engineering Standard NSW Category Signalling Title Reference Number SDS 17 (RIC Standard: SC 00 13 01 17 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards

More information

Siemens ST950 & ST900 Statement of Compliance Against TR 2513 Issue A, September 2005 Performance Specification for Wig Wag Signal Control Equipment

Siemens ST950 & ST900 Statement of Compliance Against TR 2513 Issue A, September 2005 Performance Specification for Wig Wag Signal Control Equipment Mobility and Logistics Traffic Solutions Sopers Lane Poole, Dorset BH17 7ER SYSTEM/PROJECT/PRODUCT: Traffic Controllers Siemens ST950 & ST900 Statement of Against TR 2513 Issue A, September 2005 Performance

More information

Product Information Sheet

Product Information Sheet Product Information Sheet RETB Radio Electronic Token Block Park Signalling Limited 2015 Registered number 03895736 Page 1 of 8 Introduction Radio Electronic Token Block (RETB) is an economic radio based

More information

Signalling Works Testing

Signalling Works Testing Railway Group Standard Issue Two Date September 1995 Signalling Works Testing Synopsis This standard defines the requirements for the through testing of new or altered signalling installations before they

More information

GK/GN0653. Guidance on Control of Unwanted Voltages on Telecommunications. Equipment at Stations. Rail Industry Guidance Note for GK/RT0053

GK/GN0653. Guidance on Control of Unwanted Voltages on Telecommunications. Equipment at Stations. Rail Industry Guidance Note for GK/RT0053 GN Published by: Block 2 Angel Square 1 Torrens Street London EC1V 1NY Copyright 2011 Rail Safety and Standards Board Limited GK/GN0653 Telecommunications Equipment at Stations Issue One: December 2011

More information

Electrical Procedure No E032. Procedure No: ELE 032

Electrical Procedure No E032. Procedure No: ELE 032 Procedure No: ELE 032 Procedure Title: Date of Procedure: Responsible Person(s) Safety Isolation of Low Voltage Networks and Systems for work to be carried out by third parties. i.e. Non University personnel.

More information

Control Command & Signalling. Standards Brief Sept Professional Head [S&C] 11/11/2014

Control Command & Signalling. Standards Brief Sept Professional Head [S&C] 11/11/2014 Control Command & Signalling Standards Brief Sept 2014 Professional Head [S&C] 11/11/2014 1 General This presentation gives headline details of the September 2014 Signalling Standards Brief It contains

More information

Road signs Specifications

Road signs Specifications AS 1743:2018 AS 1743:2018 Road signs Specifications This Australian Standard was prepared by Committee MS-012, Road Signs and Traffic Signals. It was approved on behalf of the Council of Standards Australia

More information

TABLE OF CONTENTS. References

TABLE OF CONTENTS. References ANALYTICAL X-RAY EQUIPMENT USE POLICIES & PROCEDURES Page 1 of 9 Revised: 11/24/2003 TABLE OF CONTENTS 1.0 General 2.0 Purpose 3.0 Scope and Authority 4.0 Equipment Requirements 4.0.1 Safety device 4.0.2

More information

Train Detection Handbook

Train Detection Handbook Page 1 of 14 Issue and revision record Section/ Issue Date Comments document 1 August 1994 New Document 2 June 1996 Renamed, formerly Track Circuit See CONTENTS for details of other documents. Train Detection

More information

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES INTERNATIONAL TELECOMMUNICATION UNION CCITT X.21 THE INTERNATIONAL (09/92) TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE DATA COMMUNICATION NETWORK: INTERFACES INTERFACE BETWEEN DATA TERMINAL EQUIPMENT

More information

Appendix Traffic Engineering Checklist - How to Complete. (Refer to Template Section for Word Format Document)

Appendix Traffic Engineering Checklist - How to Complete. (Refer to Template Section for Word Format Document) Appendix 400.1 Traffic Engineering Checklist - How to Complete (Refer to Template Section for Word Format Document) Traffic Engineering Checksheet How to Complete the Form June 2003 Version 3 Maintained

More information

ACCESS TO HIGH VOLTAGE APPARATUS

ACCESS TO HIGH VOLTAGE APPARATUS CORPORATE PROCEDURE ACCESS TO HIGH VOLTAGE APPARATUS Approved By: Prepared By: Issue Date: 17/6/2011 Andrew Macrides Access to Apparatus Rules File No: Managing Director Committee QDOC2011/63 Status: Approved

More information

ISO 2575 INTERNATIONAL STANDARD. Road vehicles Symbols for controls, indicators and tell-tales

ISO 2575 INTERNATIONAL STANDARD. Road vehicles Symbols for controls, indicators and tell-tales INTERNATIONAL STANDARD ISO 2575 Sixth edition 2000-03-15 Road vehicles Symbols for controls, indicators and tell-tales Véhicules routiers Symboles pour les commandes, indicateurs et témoins Reference ISO

More information

SECTION EDITION - REVISION 2. Large Guide

SECTION EDITION - REVISION 2. Large Guide SECTION 4 0 EDITION - REVISION Large Guide March 017 (This page left intentionally blank) Guide Sign Design Guidelines Design Guidelines There are general guidelines to follow in the design of highway

More information

Uncontrolled When Printed

Uncontrolled When Printed Briefing Note Document Title: GSM-R Train Radio Systems Document No: Issue: Issue 1 Issue 1 Subject Committee(s): The primary Subject Committees are Operations and Train Control & Communications. The Standards

More information

Muirhouse Central Junction

Muirhouse Central Junction NETWORK RAIL Scotland Route SC05 Muirhouse Central and Muirhouse North () (Maintenance) T.A..M.SC05.0.0.0..4 March 03 Network Rail / T.A..Ltd. 03 Contents Legend age T.A..M.SC05.0.0.0. January 007 age

More information

Train Voice Radio Systems

Train Voice Radio Systems Train Voice Radio Systems Synopsis This document sets out the mandatory requirements for the application of train voice radio systems, specifically interface requirements for the infrastructure manager

More information

THIRD SCHEDULE Form of Application For A Revised Disability Access Certificate Article 20E(2)

THIRD SCHEDULE Form of Application For A Revised Disability Access Certificate Article 20E(2) THIRD SCHEDULE Form of Application For A Revised Disability Access Certificate Article 20E(2) Building Control Acts 1990 and 2007 Application for a Revised Disability Access Certificate Building Control

More information

SIGNAL SIGHTING - MINIMUM STANDARDS MINIMUM STANDARDS

SIGNAL SIGHTING - MINIMUM STANDARDS MINIMUM STANDARDS SIGNAL SIGHTING - MINIMUM STANDARDS All Signal Sighting Inspections must be carried out by nominated officers of the RTBU Locomotive Division (NSW). In most situations these will be nominated Sub-Divisional

More information

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS ENGINEERING DESIGN STANDARD EDS 08-2109 LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS Network(s): Summary: EPN, LPN, SPN This standard provides guidance on the installation of

More information

Measurement of Signalling Distances

Measurement of Signalling Distances Division / Business Unit: Function: Document Type: Enterprise Services Signalling Standard Measurement of Signalling Distances Applicability ARTC Network Wide SMS Publication Requirement Internal / External

More information

Title Operating Work - Low Voltage Distribution System. Reference Number POP 06 - (RIC Standard: EP SI)

Title Operating Work - Low Voltage Distribution System. Reference Number POP 06 - (RIC Standard: EP SI) Discipline Engineering Standard - NSW Category Electrical Title Operating Work - Low Voltage Distribution System Reference Number POP 06 - (RIC Standard: EP 95 30 00 03 SI) Document Control Status Date

More information

Guidance Material for ILS requirements in RSA

Guidance Material for ILS requirements in RSA Guidance Material for ILS requirements in RSA General:- Controlled airspace required with appropriate procedures. Control Tower to have clear and unobstructed view of the complete runway complex. ATC to

More information

EUROPEAN pr ETS TELECOMMUNICATION February 1996 STANDARD

EUROPEAN pr ETS TELECOMMUNICATION February 1996 STANDARD FINAL DRAFT EUROPEAN pr ETS 300 118 TELECOMMUNICATION February 1996 STANDARD Second Edition Source: ETSI TC-TE Reference: RE/TE-05049 ICS: 33.020 Key words: PSTN, modems Public Switched Telephone Network

More information

Newport Area Signalling Renewals Phase 2 Newnham Tunnel Caldicot

Newport Area Signalling Renewals Phase 2 Newnham Tunnel Caldicot GIOCONA Newport Area Signalling Renewals Phase 2 Newnham unnel Caldicot.A.P.M285.0.0.0.1 G700 2012 Newport Area Signalling Renewals Phase 2 G700 Newnham unnel Caldicot Newnham unnel Gloucester Existing

More information

TOWN OF OAKVILLE FIRE ROUTE APPLICATION PACKAGE

TOWN OF OAKVILLE FIRE ROUTE APPLICATION PACKAGE TOWN OF OAKVILLE FIRE ROUTE APPLICATION PACKAGE This application package contains: Page1. 2. 3. 4. 5. 6. 7. Application Process Description Minimum Fire Route Design Requirements Drawing Requirements Sample

More information

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance National Grid UK Electricity Transmission plc NATIONAL SAFETY INSTRUCTION and Guidance NSI 26 RAILWAY CONNECTION CIRCUITS Copyright National Grid plc 2016, all rights reserved. No part of this publication

More information

Australian Standard. Switchgear assemblies and ancillary equipment for alternating voltages above 1 kv AS

Australian Standard. Switchgear assemblies and ancillary equipment for alternating voltages above 1 kv AS AS 2067 1984 Australian Standard Switchgear assemblies and ancillary equipment for alternating voltages above 1 kv [Title allocated by Defence Cataloguing Authority: SWITCHGEAR ASSEMBLIES, ELECTRICAL AND

More information

Provläsningsexemplar / Preview

Provläsningsexemplar / Preview Provläsningsexemplar / Preview SS-ISO 2575:2010 (E) Contents Page Foreword...iv 1 Scope...1 2 Normative references...1 3 Terms and definitions...1 4 General...2 5 Colour...3 6 Summary table of all symbols...3

More information

CHAPTER 11 PRELIMINARY SITE PLAN APPROVAL PROCESS

CHAPTER 11 PRELIMINARY SITE PLAN APPROVAL PROCESS CHAPTER 11 PRELIMINARY SITE PLAN APPROVAL PROCESS 11.01.00 Preliminary Site Plan Approval 11.01.01 Intent and Purpose 11.01.02 Review 11.01.03 Application 11.01.04 Development Site to be Unified 11.01.05

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 300 330-2 V1.1.1 (2001-06) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment

More information

Performance Specification for Nearside Signal and Demand Unit

Performance Specification for Nearside Signal and Demand Unit traffic systems and signing TR 2511 Issue A July 2005 Performance Specification for Nearside Signal and Demand Unit Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency

More information

Signalling Documentation and Drawings

Signalling Documentation and Drawings Discipline: Engineering (Signalling) Category: Standard Signalling Documentation and Drawings SCP 06 Applicability New South Wales CRIA (NSW CRN) Primary Source RIC Standard SC 00 23 00 00 SP Version 3.0

More information

Status Date Prepared Reviewed Endorsed Approved

Status Date Prepared Reviewed Endorsed Approved Discipline Engineering Standard - NSW Category Signalling Title Reference Number SPS 12 - (RIC Standard: SC 07 10 01 00 SP) Document Control Status Date Prepared Reviewed Endorsed Approved May 05 Standards

More information

Procedure Mining Two Way Radio Usage (Surface)

Procedure Mining Two Way Radio Usage (Surface) Procedure Mining () M-SF-008 Relevant to: Business Unit: Mining Division: Document Owner: General Manager West Revision Status: Revision Date Section Page/s Revision Description Reviewed By Approved By

More information

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal City of Winnipeg Brady Road Landfill Site Section 01300 New Entrance and Scale Facility Page 1 of 4 SUBMITTALS 1. SHOP DRAWINGS 1.1 General.1 Arrange for the preparation of clearly identified Shop Drawings

More information

Earthing Requirements for HV Transmission Structures

Earthing Requirements for HV Transmission Structures Engineering Standard Electrical MEST 000002-07 Earthing Requirements for Transmission Structures Version: 1 Issued: February 2015 Owner: Engineering Approved By: Patrick Kelly Head of Electrical Engineering

More information

TYPE APPROVAL PROCEDURE

TYPE APPROVAL PROCEDURE Approval Amendment Record Approval Date Version Description 15/06/2012 1 Initial issue under MTM. Replaces Connex documents cml- 8.13-PR-002 & cml-8.21-po-168 30/11/2012 2 Document revised and updated

More information

ETSI EN V1.5.1 ( ) Harmonized European Standard (Telecommunications series)

ETSI EN V1.5.1 ( ) Harmonized European Standard (Telecommunications series) EN 300 330-2 V1.5.1 (2010-02) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment in the

More information

Drawing Standard for Plans Showing Horizontal Alignment

Drawing Standard for Plans Showing Horizontal Alignment Discipline: Engineering (Track & Civil) Category: Standard Drawing Standard for Plans Showing Horizontal Alignment ETD-00-01 Applicability New South Wales CRIA (NSW CRN) Primary Source ARTC NSW Standard

More information

Performance Specification for Light Signals for the Control of Tramcars

Performance Specification for Light Signals for the Control of Tramcars traffic systems and signing TR 2514 Issue A Sept 2005 Performance Specification for Light Signals for the Control of Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency

More information

Performance Specification for Below Ground Vehicle Detection Equipment

Performance Specification for Below Ground Vehicle Detection Equipment traffic systems and signing TR 2512 Issue A Sept 2005 Performance Specification for Below Ground Vehicle Detection Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency

More information

Guide Sign Policy for Secondary State Highways Edition

Guide Sign Policy for Secondary State Highways Edition Massachusetts Highway Department, Ten Park Plaza, Boston, MA 02116-3973 ` Guide Sign Policy for Secondary State Highways 2005 Edition Revised September 2005 1. PURPOSE The Massachusetts Highway Department

More information

Suppliers' Information Note. BT Metallic Path Facility. Interface Description

Suppliers' Information Note. BT Metallic Path Facility. Interface Description SIN 349 Issue 2.5 August 2015 Suppliers' Information Note For The BT Network BT Metallic Path Facility Interface Description Each SIN is the copyright of British Telecommunications plc. Reproduction of

More information

SUBJECT HEADING: Switching Programmes ISSUE: 18

SUBJECT HEADING: Switching Programmes ISSUE: 18 SUBJECT: Switchgear/Switching PROCEDURE: S04 SUBJECT HEADING: Switching Programmes ISSUE: 18 DATE: Apr 2017 1. INTRODUCTION 1.1 A written programme of switching operations shall be prepared. This programme

More information

NEW FIXED WIRING COLOURS. A practical guide

NEW FIXED WIRING COLOURS. A practical guide EW FIXED WIRIG COLOURS A practical guide EWWIRIGCOLOURS EW FIXED WIRIG COLOURS - A practical guide The changes to the colour identification of conductors in fixed wiring are introduced, amongst other things,

More information

PUBLICATION 213. Think Safety First

PUBLICATION 213. Think Safety First PUBLICATION 213 (67 PA CODE, CHAPTER 212) Think Safety First Pub 213 (02-08) Appendix Appendix A - Temporary/Portable

More information

This document contained the major International agreements, plus United States radio laws and regulations, current at the time of publication.

This document contained the major International agreements, plus United States radio laws and regulations, current at the time of publication. Do You Know? On June 27, 1914 the Department of Commerce published a new document called Regulations Governing Radio Operators And The Use Of Radio Apparatus On Ships And On Land. (http://earlyradiohistory.us/1914reg.htm#ra4-15)

More information

Guideline for Creating Disconnection Points and Establishing a Not Electrically Connected Area

Guideline for Creating Disconnection Points and Establishing a Not Electrically Connected Area Guideline for Creating Disconnection Points and Establishing a Not Document Number: Authorised by: Issue Date: 29 June 2012 Previous Document: 12 February 2010 Principal Authors: J Dohmen Powerlink D Brown

More information

Network Standard NS

Network Standard NS Network Standard NS 21-2006 Artwork on Western Power Assets Technical Requirements for application to South West Interconnected System (SWIS) DMS #1049174 NS 21-2006 Artwork on Western Power Assets REVISION

More information

TECHNICAL TBR 2 BASIS for January 1997 REGULATION

TECHNICAL TBR 2 BASIS for January 1997 REGULATION TECHNICAL TBR 2 BASIS for January 1997 REGULATION Source: ETSI TC-TE Reference: DTBR/TE-005002 ICS: 33.020, 33.040.40 Key words: PDN, testing, type approval, X.25 Attachment requirements for Data Terminal

More information

Date of hosting on website: 28 th July 2017 Last date for comments: 10 th August 2017

Date of hosting on website: 28 th July 2017 Last date for comments: 10 th August 2017 Date of hosting on website: 28 th July 2017 Last date for comments: 10 th August 2017 CHECK LIST FOR PREPARING AMENDMENT TO AUTOMOTIVE INDUSTRY STANDARD (AIS) Draft Amd. No 2 to AIS-071 (Part 1):- Automotive

More information

Standards Australia LICENCE

Standards Australia LICENCE Standards Australia LICENCE Title: Licensee: Date: Conditions of use (Click here for full conditions of Licence) Check if current WEB SEARCH Find similar documents StandardsWatch (Info and Login) Visit

More information

ISO Graphical symbols Safety colours and safety signs Part 3: Design principles for graphical symbols for use in safety signs

ISO Graphical symbols Safety colours and safety signs Part 3: Design principles for graphical symbols for use in safety signs INTERNATIONAL STANDARD ISO 3864-3 Second edition 2012-02-01 Graphical symbols Safety colours and safety signs Part 3: Design principles for graphical symbols for use in safety signs Symboles graphiques

More information

AS Australian Standard. Guarding and safe use of woodworking machinery. This is a free 7 page sample. Access the full version online.

AS Australian Standard. Guarding and safe use of woodworking machinery. This is a free 7 page sample. Access the full version online. AS 1473 1991 Australian Standard Guarding and safe use of woodworking machinery This Australian Standard was prepared by Committee SF/7, Guarding of Woodworking Machinery. It was approved on behalf of

More information

AWS J1.1M/J1.1:2013 An American National Standard. Specification for Resistance Welding Controls

AWS J1.1M/J1.1:2013 An American National Standard. Specification for Resistance Welding Controls An American National Standard Specification for Resistance Welding Controls An American National Standard Approved by American National Standards Institute July 29, 2013 Specification for Resistance Welding

More information

SECTION 35 ANTENNAS AND TOWERS

SECTION 35 ANTENNAS AND TOWERS SECTION 35 ANTENNAS AND TOWERS Section: 515-35-1 Purpose and Intent 515-35-2 General Standards 515-35-3 Certification, Inspection and Maintenance 515-35-4 Tower Design 515-35-5 Co-Location Requirement

More information

ETSI EN V1.2.1 ( ) Harmonized European Standard (Telecommunications series)

ETSI EN V1.2.1 ( ) Harmonized European Standard (Telecommunications series) EN 300 086-2 V1.2.1 (2008-09) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment with an internal

More information

Plain bearings Wrapped bushes

Plain bearings Wrapped bushes BRITISH STANDARD BS ISO 3547-3:2006 Plain bearings Wrapped bushes Part 3: Lubrication holes, grooves and indentations ICS 21.100.10 National foreword This British Standard was published under the authority

More information

Product Guide Verizon Delaware LLC. Section 31 Delaware LLC Original Sheet 1. Connection With Certain Facilities of Others

Product Guide Verizon Delaware LLC. Section 31 Delaware LLC Original Sheet 1. Connection With Certain Facilities of Others Delaware LLC Original Sheet 1 A. GENERAL Part 68 of the Federal Communications Commission's Rules and Regulations applies to customer premises equipment, with specified exceptions. Accordingly, regulations

More information

Guide on the General and Administrative Aspects of the Voluntary System of Modular Evaluation of Measuring instruments

Guide on the General and Administrative Aspects of the Voluntary System of Modular Evaluation of Measuring instruments WELMEC 8.8, 2017 Guide on the General and Administrative Aspects of the Voluntary System of Modular Evaluation of Measuring instruments For information: The amendments in this guide (red) are available

More information

AT&T INDIANA GUIDEBOOK. PART 2 - General Terms and Conditions 1st Revised Sheet 1 SECTION 9 - Connections

AT&T INDIANA GUIDEBOOK. PART 2 - General Terms and Conditions 1st Revised Sheet 1 SECTION 9 - Connections PART 2 - General Terms and Conditions 1st Revised Sheet 1 EXCHANGE SERVICES 1. General Provisions A. General Terminal equipment and communications systems provided by the customer may be connected at the

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment with an internal or external RF connector

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 300 718-2 V1.1.1 (2001-05) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Avalanche Beacons; Transmitter-receiver

More information

ETSI EN V1.2.1 ( )

ETSI EN V1.2.1 ( ) EN 300 113-2 V1.2.1 (2002-04) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land mobile service; Radio equipment intended

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-21567-5 SOUTH AFRICAN NATIONAL STANDARD Lights for motor vehicles Part 1: Incandescent lamps Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded INTERNATIONAL STANDARD ISO 17636 First edition 2003-09-15 Non-destructive testing of welds Radiographic testing of fusionwelded joints Contrôle non destructif des assemblages soudés Contrôle par radiographie

More information

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION INTERNATIONAL TELECOMMUNICATION UNION CCITT G.703 THE INTERNATIONAL TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE (11/1988) SERIE G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS General

More information

EE Limited - Public Wireless Network Licence Company Registration no First Issued: 26/03/93 - Licence Number: Rev: 20-10/01/17

EE Limited - Public Wireless Network Licence Company Registration no First Issued: 26/03/93 - Licence Number: Rev: 20-10/01/17 Office of Communications (Ofcom) Wireless Telegraphy Act 2006 EE Limited - Public Wireless Network Licence PUBLIC WIRELESS NETWORK LICENCE This Licence document replaces the version of the Licence issued

More information

AS Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE. This is a free 5 page sample. Access the full version online.

AS Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE. This is a free 5 page sample. Access the full version online. AS 1310 1987 Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE This Australian Standard was prepared by Committee BD/23, Structural Steel. It was approved on behalf of the Council of the

More information

Town of Holly Springs Sign Installation Packet

Town of Holly Springs Sign Installation Packet Town of Holly Springs Sign Installation Packet Department of Planning & Zoning 128 S. Main Street P.O. Box 8 Holly Springs, NC 27540 (919) 557-3908 HSPlanning@hollyspringsnc.us GENERAL INFORMATION: If

More information

LICENCE. for WEB LINKS. Check if this document is current Find similar documents StandardsWatch (info and login) Visit our website

LICENCE. for WEB LINKS. Check if this document is current Find similar documents StandardsWatch (info and login) Visit our website LICENCE for Licensee: Date: Conditions of use: Click here for full conditions of Licence WEB LINKS Check if this document is current Find similar documents StandardsWatch (info and login) Visit our website

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-28950-8 Any reference to SABS 098-1 is deemed to be a reference to this standard (Government Notice No. 1373 of 8 November 2002) SOUTH AFRICAN NATIONAL STANDARD Public lighting Part 1: The

More information

LIMITS FOR TEMPORARY OVERVOLTAGES IN ENGLAND AND WALES NETWORK

LIMITS FOR TEMPORARY OVERVOLTAGES IN ENGLAND AND WALES NETWORK LIMITS FOR TEMPORARY OEROLTAGES IN ENGLAND AND WALES NETWORK This document is for internal and contract specific use only. Disclaimer NGG and NGET or their agents, servants or contractors do not accept

More information

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS 101 General 102 Submittal Requirements A. Initial Submittal B. Second Submittal 103 Plan Requirements A. Subdivisions B. Site Plans 104 Approval of

More information

SYNCHRONISING AND VOLTAGE SELECTION

SYNCHRONISING AND VOLTAGE SELECTION SYNCHRONISING AND VOLTAGE SELECTION This document is for Relevant Electrical Standards document only. Disclaimer NGG and NGET or their agents, servants or contractors do not accept any liability for any

More information

PRODUCT MANUAL. AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 ISO ISO 9001 Registered Quality Management. Registered Environmental Management

PRODUCT MANUAL. AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 ISO ISO 9001 Registered Quality Management. Registered Environmental Management ISO 14001 PRODUCT MANUAL ISO 9001 Registered Quality Management 015 Registered Environmental Management 015 AGD Systems Limited 2016 Doc. Ref. 932 PM ISS3 TABLE OF CONTENTS INTRODUCTION Product & technology

More information

HT1100 Satellite Modem User Guide

HT1100 Satellite Modem User Guide HT1100 Satellite Modem User Guide 1039650-0001 Revision C October 11, 2013 11717 Exploration Lane, Germantown, MD 20876 Phone (301) 428-5500 Fax (301) 428-1868/2830 Copyright 2013 Hughes Network Systems,

More information

Guidelines on the Use of Portable Traffic Signals (PTS)

Guidelines on the Use of Portable Traffic Signals (PTS) Technical Circular T-04/07 Date: August 3, 2007 To: All HQ Directors: Operations, Planning and Major Projects All Regional Directors All Regional Traffic Engineers All District Managers, Transportation

More information

VHF LAND MOBILE SERVICE

VHF LAND MOBILE SERVICE RFS21 December 1991 (Issue 1) SPECIFICATION FOR RADIO APPARATUS: VHF LAND MOBILE SERVICE USING AMPLITUDE MODULATION WITH 12.5 khz CARRIER FREQUENCY SEPARATION Communications Division Ministry of Commerce

More information

ETSI EN V1.3.2 ( ) Harmonized European Standard (Telecommunications series)

ETSI EN V1.3.2 ( ) Harmonized European Standard (Telecommunications series) EN 302 288-2 V1.3.2 (2009-01) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices; Road Transport and Traffic Telematics

More information

Australian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL. Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE

Australian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL. Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE AS 2177, Part 2 1982 Australian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE This standard, prepared by Committee MT/7, Non-destructive

More information

Australian Standard. ISO system of limits and fits. Part 1: Bases of tolerances, deviations and fits AS ISO 286-1:1988

Australian Standard. ISO system of limits and fits. Part 1: Bases of tolerances, deviations and fits AS ISO 286-1:1988 AS 1654.1 1995 ISO 286-1:1988 Australian Standard ISO system of limits and fits Part 1: Bases of tolerances, deviations and fits This Australian Standard was prepared by Committee ME/27, Engineering Tolerance

More information

1. The Office of Communications (Ofcom) grants this wireless telegraphy licence ( the Licence ) to

1. The Office of Communications (Ofcom) grants this wireless telegraphy licence ( the Licence ) to Office of Communications (Ofcom) Wireless Telegraphy Act 2006 Telefónica UK Limited - Public Wireless Network Licence PUBLIC WIRELESS NETWORK LICENCE This Licence document replaces the version of the Licence

More information