Managing Complex Impedance, Isolation & Calibration for KGD RF Test Abstract

Size: px
Start display at page:

Download "Managing Complex Impedance, Isolation & Calibration for KGD RF Test Abstract"

Transcription

1 Managing Complex Impedance, Isolation & Calibration for KGD RF Test Roger Hayward and Jeff Arasmith Cascade Microtech, Inc. Production Products Division 9100 SW Gemini Drive, Beaverton, OR , Abstract -- This paper outlines a number of the most common issues involved with preparing a probe card for Known Good Die (KGD) RF test. These include managing complex impedance, isolation between RF ports, and establishing a plan for RF calibration. For each issue, proactive planning will improve the test accuracy, coverage and repeatability on the test floor. INTRODUCTION Over the past 20 years, consumer RF devices have evolved significantly. Many devices incorporate both RF transceivers and digital sub-systems. Other process-specific components are manufactured for System-In-Package (SIP) applications. Because of this, fabricated components must now be tested thoroughly on-wafer. In many cases, testing for Known Good Die (KGD) is the only time the circuit will be tested prior to integration. Although every RF device designed is created to fill a unique niche, most of the technical challenges behind probing have common themes to them: Low insertion loss, high port-to-port isolation, repeatable RF performance, accurate calibration, accurate power measurement, high bandwidth, low lead inductance, high power, etc. There are times when the design phase of a new product does not consider the need to accurately probe the die for KGD test. This can increase the time required to ramp the part into high volume. Figure 1 Cascade Microtech Pyramid Probes for KGD RF test. This paper presents solutions for a number of challenges faced during wafer-level RF test. Impedance matching networks enable accurate power measurements. Packaged-part bond wire

2 parasitics need to be minimized, controlled or emulated in the probe card. Controlled-impedance paths improve port-to-port isolation. Finally, establishing a solid, repeatable plan for RF calibration will improve the coverage and accuracy during KGD test. Proper pad placements of RF interfaces will ease the burden of moving a new device into RF test, although this is not always possible. Using best known methods, consider drawing RF ports with ground-signal-ground (GSG) interfaces. Uniform pitch & alignment between ports is helpful as well. When these opportunities are not available, other techniques may be utilized. These will be discussed below. High volume, high density probing is accomplished with the Cascade Microtech Pyramid Probe, revealed in Figure 1 above. Traces are routed within a thin-film polyimide flex circuit. This fabrication technique allows microwave transmission lines to be routed with controlled impedance directly to the probe tip. Low impedance power & control lines are routed in the thin-film as well. MANAGING COMPLEX IMPEDANCE Most consumer RF interfaces do not present 50 ohm impedances to their output. When this is the case, it becomes necessary to add an impedance matching network to the path between the device and the test instrument. For KGD tests, this may reduce a complicated correlation down to a simple power measurement. Power measurements may be performed by a VNA, ATE, or with a low-cost power detection circuit incorporated into the probe card. The port impedance needs to be characterized prior to probe card design. This may be an estimate from simulation, or load-pull measurement. Using the target matching network, sample devices may be probed. An initial design may be completed with these early samples. The final impedance may need to be adjusted slightly by altering one or more components in the network. For devices with high levels of integration, powering up a device for impedance measurements can be a difficult effort. Consider adding a test mode to enable active devices without the added complexity of outboard controllers, firmware, etc. Modes of this sort will allow sub-tests to be completed before the final integration stages. Lumped-Element Impedance Matching For narrowband applications, a lumped-element low-pass or high-pass network usually provides enough flexibility to move the impedance to 50 ohms. A short-length transmission line connects the DUT pads to the matching network. This transmission line must be included as part of the network design. An example matching network is shown in Figure 2 below. Remember that the wires shown in schematics indicate connectivity between components, but nothing else. If components are separated by any distance, the layout will need to include a transmission line which models that portion of the path. In this case, the transmission line TL 1 represents the electrical length from the probe tip, through the thin-film membrane, and onto the printed circuit board (PCB).

3 E D C B A Port1 L2 C1 L1 TL1 Device Figure 2 Generic low pass impedance matching network. The path includes a transmission line between the DUT and the matching network. Narrowband impedance matching can be designed by utilizing the Smith chart. Impedance is plotted at the center frequency. The plot in Figure 3 includes the impedance of the circuit from Figure 2, as components are introduced from right to left. Start by measuring S 11 looking into point "A," as shown in the figures. The transmission line length is a fixed electrical delay that cannot be changed after the probe card is assembled. Lumped element components are used to shift the impedance to the real axis. Series inductors add reactance, following the constant-resistance path on the Smith chart. Shunt capacitors add capacitive susceptance (lowering the reactance), following the constantconductance path on the chart. Figure 3 Following the impedance from the DUT to 50 ohms. In the example shown in Figure 3, point "A" represents the impedance seen at the device. The initial impedance is 30 + j40 ohms (inductive reactance). The 50 ohm transmission line shifts this impedance to point "B," 30 - j40 ohms (capacitive reactance). L 1 shifts the impedance to an inductive reactance again, seen at point "C." Contributions from the shunt capacitor C 1 lower the

4 impedance to point "D." Finally, L 2 adds a small amount of inductive reactance to obtain 50 ohms. In a high volume production probe, the lumped-element matching network may be implemented on the printed circuit board, or within the probe itself. In either case, it is important to understand the electrical length delay of the transmission line between the probe tip and the first lumped element. (This is the path between point "A" and "B" on the Smith chart above). Although transmission line losses should be kept to a minimum, this loss can be modeled or measured prior to design of the matching network. 50 ohm 20 ohm 10 ohm Figure 4 Example thin-film probe layout, with 10, 20 and 50 ohm microstrip transmission lines leaving the device. Depending upon how much is understood about the device impedance, it may be difficult to predict the best topology to use for the lumped element matching network. It may be beneficial to add additional shunt and series elements to the chain. For example, the first element may need to be a shunt capacitor if the impedance appears inductive. Proper selection of components will dictate how many or few components are required to achieve an acceptable match. One additional technique for impedance adjustment is to add a series of adjacent shunt elements into the layout of the matching network, such that one shunt element can be introduced at a sliding location along the transmission line. Careful placement of a shunt reactive component may greatly minimize the number of components required to obtain a perfect match. After designing the matching network, it is useful to measure S 11 of the network prior to powering up the device. By terminating onto a 50 ohm structure, the effects of the lumped-element structure (only) may be observed and verified independent of device characterization. Quarter-Wave Transformer Matching The quarter-wave transformer is another technique for narrowband impedance matching a load impedance to a transmission line 1. Matching the DUT impedance Z L to the transmission line impedance Z 0 is accomplished by using a quarter-wavelength matching network impedance

5 Z TL1, where ZTL 1 = Z0Z L. This technique is useful for transforming from low or high impedance, back to 50 ohms. C B A Port1 TL2 Z=50 Ohm E=Any TL1 Z=16 Ohm E=90 R1 R=5 Ohm Z TL1 = 50 5 = 16Ω Figure 5 Quarter wave transmission line matching network example. Consider the example of a device with 5 ohms output impedance in Figure 5. This may be matched with a quarter-wave 16 ohm transmission line. No other elements are required to achieve 50 ohms. Once the quarter wave transform has completed, the path may continue in 50 ohm line for as long as is required. λ 8 0λ λ 4 Figure 6 Quarter wave transformer matching network from Figure 5. A 16 ohm transmission line matches the 5 ohm load to 50 ohms. Lower impedance transmission lines are useful for power device matching networks. The lower impedance implies a larger structure within the thin-film, which translates to less power loss. The length of the quarter wave transmission line may exceed the distance on the thin-film portion of the probe card for lower frequencies. Lumped elements may be placed on the printed circuit board. For higher frequencies, the quarter wave line may be drawn to length on the membrane, as shown in Figure 7 below.

6 Figure 7 Thin-film probe layout of a quarter-wave transmission line matching network. Transmission line was drawn to match exact length. A shunt SMT component may be added for fine tuning. The 50 ohm transmission line leaves the membrane to the left. Mixed Transmission Line, Lumped Element Example The quarter wave transmission line technique may be used to match to complex impedances as well. By varying the length of the transmission line slightly, a reactive load may be transformed directly to 50 ohms, or to a point near 50 ohms. (The length of the transmission line does not necessarily have to be exactly a quarter wavelength). Although a small lumped element network may be required in order to achieve an optimal match, the quarter wave transmission line will still perform the bulk of the work. D C B A Port1 TL2 Z=50 Ohm E=Any L L1 L=2nH TL1 Z=18 Ohm E=85 Device1 Z[1]=5+j4 Ohm Figure 8 Mixed matching network example. Network transforms 5 + j4 ohms to 50 ohms. In Figure 8 above, a complex impedance of 5 + j4 ohms is matched to 50 ohms with a transmission line, slightly shorter than a quarter wave. Because the exact impedance of the device may not be known until devices are available to probe, the length and impedance of the transmission line may be estimates. In this example, the Z TL1 impedance chosen is 18 ohms. The impedance at point "B" can be corrected with one series inductor.

7 Figure 9 Mixed matching network example from Figure 8. Transmission line section performs most of the match. A lumped element network performs final correction. The topology and design of the impedance matching network can be determined from initial simulation or measurements of the device. Since simulated S-parameter data can provide a reasonable starting point, most of the network may be designed and integrated into the probe card. Final adjustments to 50 ohms may be performed with a small, flexible-topology lumped element network on the printed circuit board. EMULATING LEAD INDUCTANCE When designing RF components, the parasitic effects of final packaging are always a concern. Often, it is important to include the effects of the package's lead inductance as a part of the final circuit. This is especially an issue with high-frequency narrowband filters. When probing circuits for KGD test, the probing system is unlikely to have the same lead inductance as the final package. This difference will load the circuit differently, causing different measurement results. In the case of narrowband filters, this will alter the insertion loss, the pass band ripple, and even shift the center and notch frequencies slightly. Unfortunately, it is not always straightforward to calibrate out the effects of lead inductance. Series inductance on the signal lines may be augmented, post-calibration. However, return paths (ground) are more difficult to de-embed. For this reason, it is important for some circuits to load them with the similar parasitics as will be expected after packaging. One way to include the effects of the bond wire inductance is to incorporate the inductance into the probe itself. The series inductance of the bond wire may be emulated through a thin-film inductor, placed right at the probe tip. The inductance may be set to any value from 300pH to 10nH, or may be measured and trimmed after fabrication of the probe.

8 Figure 10 Example thin-film probe layout, emulating bond wire inductors. Rungs of the ladder are cut to achieve desired inductance, to within 100pH. All paths to the package incorporate bond wire inductance. PROBE ISOLATION MUST EXCEED THE MEASUREMENT NEEDS Port-to-port isolation of the device must be verified as well as direct-path connectivity, for some wireless components, especially switches & filters. The probing ports must demonstrate isolation which exceeds the expected isolation of the device itself. In order to achieve high isolation, the fringe fields of the signals must be kept to a minimum. All close, parallel paths between transmission lines should be eliminated. If possible, high-isolation pairs should arrive at the DUT from different angles, ideally at 90 degrees (or greater). Figure 11 Example thin-film probe layout for a multi-position RF switch. Transmission lines are coplanar waveguide, to minimize loss. Figure 11 above reveals a probe for a multi-position RF switch used for cellular communications. The antenna and transmitter power amplifier are connected from the left. In order to maximize the port isolation, all receiver paths are connected to the DUT from the other quadrants of the probe. The closest coupling distance is approximately 700 microns across the die. The thin-film transmission lines are routed as coplanar waveguide to minimize path loss. The typical isolation with this layout approach is 2.4 GHz.

9 ESTABLISHING A PLAN FOR RF CALIBRATION RF Calibration is an essential step for proper KGD test. Network analyzer calibration is different from traditional calibration of most lab instruments. Slight changes in environmental conditions (temperature, humidity) as well as aging of critical devices within the instrument require periodic characterization. The measurement accuracy determines how often the network analyzer should be re-calibrated. It is not unusual to calibrate on a daily basis, or at the beginning of a work shift. Calibration may be accomplished by a number of techniques. These include coaxial calibration, calibration with port extensions, fixture de-embedding, and calibration at the probe tips. Coaxial Calibration & Port Extensions Coaxial calibration involves characterizing the loss and delay between the measurement equipment, and the end of the test cables. Once this characterization has been performed, the errors are subtracted mathematically from the measurement. This is known as establishing a reference plane. Figure 12 Network analyzer port with cable calibration. The probe assembly must be accounted-for, prior to performing measurements. Mechanical standards are connected at the end of the test cables. The network analyzer software includes wizards to guide the operator through the process of connecting a short, an open, and a 50 ohm load to each port. The calibration is completed by presenting a thru-path between all combinations of ports. The errors are computed and stored by the network analyzer. Coaxial calibration does not account for the loss & delay within the probe card. Subsequent measurements will include these losses. Network analyzers allow an electrical length delay, as well as a linear loss estimate to be subtracted from each port s measurements. This technique is referred to as a port extension. This extends the reference plane closer to the device under test, as shown in Figure 12 above. Fixture De-Embedding Fixture de-embedding replaces the port extension with a characterized model. Each RF path on the probe card may be characterized for loss, delay & reflections. The errors are represented as a two-port S-parameter model, stored in a Touchstone file. The network analyzer or ATE system will concatenate this error model onto the loss information obtained during coaxial calibration. It is important to characterize each port within the probe card system separately, as each path will have unique electrical lengths and losses.

10 Figure 13 Network analyzer port with fixture de-embedding. Probe characterization is de-embedded from the cable calibration. Tip Calibration Techniques Calibration may be performed directly at the probe tips, using similar techniques. Impedance Standard Substrates (ISS) are designed to match probes for device characterization and process monitoring. When probing such standards, the operator must either develop a calibration kit for the network analyzer 2 or ATE, or perform the calibration with tools such as WinCal 3. Probing an ISS with a production probe card requires careful planning. The probe tip configuration must be capable of landing onto known standards. The prober must be capable of aligning to the ISS. A thru-path between two ports is required for most calibration techniques. When industry-standard substrates do not match the DUT configuration, it may become necessary to build custom standards to match the probe. A custom thru structure is revealed in Figure 14(b) below. The device layout is replicated. Two of the three RF ports are connected with a 50 ohm transmission line. Other port-to-port thru paths are replicated elsewhere on the structure. One of the common concerns associated with VNA calibration is which algorithm to use. These include TRL, SOLT, LRM and LRRM, as well as many others. Each has their advantages and disadvantages 4,5. For custom RF devices, the probe cards present the additional challenge that the probe positions cannot be altered. This places additional limitations on the choice of which algorithm to use for calibration. For frequencies of interest in the 1-6 GHz range, the SOLR 6 calibration technique has a unique advantage for custom device RF probing. SOLR stands for "Short, Open, Load, Reciprocal." The advantage of this particular calibration technique is that the port-to-port thru-path does not need to be perfect. (This is frequently referred to as the unknown thru technique). As a final step, it is helpful to land on a few known standards, to confirm the calibration produces the desired results. Using known standards, measure S 11 to verify that the 50 ohm load is at the center of the Smith chart and the open and short are dots on the right and left side, respectively. Measuring S 21 on the thru standard should reveal an insertion loss at or near 0 db (the loss measured is the loss between the two probe tips only). Short-length transmission lines are also useful structures to probe for verification.

11 Figure 14 Substrates for probe tip RF calibration. (A) A standard ISS (left) provides short, load & thru paths for um GSG probes. (B) Custom structure (right) provides a thru path to match the probe's layout. Designing for Calibration A few design considerations prior to tape out will greatly improve your success when probing for known-good-die. Maintain a fine pitch, 100 to 200um, ground-signal-ground (GSG) configuration. Since the RF field exists in the region between the wires, the return path for RF is just as critical as the driven line. Even at 2 GHz, it is best to place ground pads next to each RF signal. For 2-port calibration, consider placing RF ports in a direct line with each other. For multi-port devices, place respective RF ports at 90 degree angles. This will allow general purpose structures to be used for thru-path verification. The most difficult patterns to align to a standard substrate are when both ports are on the same side of the device. It is equally challenging when ports are on opposite sides of the device, but are not directly across from one another. Confirm that every RF port will have a respective set of standards to probe for calibration and verification. It may be more beneficial to alter the pad placements than to design custom standards to match the probe after tape out. Even when this is not possible, it is always useful to have known standards such as a short, open, load & thru to probe in place of the device. SUMMARY The techniques discussed will lower the time required to bring a new design into high volume production. Proactive design-for-test considerations will result in lower test times, increased accuracy and repeatability, which will ultimately lower the cost to perform the tests. When optimal pad placement is not available, alternate methods may still be employed to insure accurate, repeatable measurements on the test floor "Microwave Engineering," David Pozar, 3rd Edition, 2005, Wiley. "Specifying Calibration Standards and Kits for Agilent Vector Network Analyzers," Application Note , Agilent Technologies. More information on WinCal may be found online at "RF Measurements of Die and Packages," Scott Wartenberg, 2002, Artech House, Inc. On Wafer Vector Network Analyzer Calibration & Measurements, 1998, Cascade Microtech Application Note. See "An SOLR Calibration for Accurate Measurement of Orthogonal On-Wafer DUTs," IEEE MTT-S International Microwave Symposium, Denver, CO, June 1997.

Introduction to On-Wafer Characterization at Microwave Frequencies

Introduction to On-Wafer Characterization at Microwave Frequencies Introduction to On-Wafer Characterization at Microwave Frequencies Chinh Doan Graduate Student University of California, Berkeley Introduction to On-Wafer Characterization at Microwave Frequencies Dr.

More information

Comparison of Various RF Calibration Techniques in Production: Which is Right for You? Daniel Bock, Ph.D.

Comparison of Various RF Calibration Techniques in Production: Which is Right for You? Daniel Bock, Ph.D. Comparison of Various RF Calibration Techniques in Production: Which is Right for You? Daniel Bock, Ph.D. Overview Introduction How does Calibration Work Types of Calibrations Comparison of Calibration

More information

Wafer-Level Calibration & Verification up to 750 GHz. Choon Beng Sia, Ph.D. Mobile:

Wafer-Level Calibration & Verification up to 750 GHz. Choon Beng Sia, Ph.D.   Mobile: Wafer-Level Calibration & Verification up to 750 GHz Choon Beng Sia, Ph.D. Email: Choonbeng.sia@cmicro.com Mobile: +65 8186 7090 2016 Outline LRRM vs SOLT Calibration Verification Over-temperature RF calibration

More information

Schematic-Level Transmission Line Models for the Pyramid Probe

Schematic-Level Transmission Line Models for the Pyramid Probe Schematic-Level Transmission Line Models for the Pyramid Probe Abstract Cascade Microtech s Pyramid Probe enables customers to perform production-grade, on-die, full-speed test of RF circuits for Known-Good

More information

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements DesignCon 2008 Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements Robert Schaefer, Agilent Technologies schaefer-public@agilent.com Abstract As data rates continue to rise

More information

Verification of LRRM Calibrations with Load Inductance Compensation for CPW Measurements on GaAs Substrates

Verification of LRRM Calibrations with Load Inductance Compensation for CPW Measurements on GaAs Substrates Verification of LRRM Calibrations with Load Inductance Compensation for CPW Measurements on GaAs Substrates J.E. Pence Cascade Microtech, 2430 NW 206th Avenue, Beaverton, OR 97006 Abstract The on-wafer

More information

WinCal XE. Leonard Hayden Cascade Microtech, Inc.

WinCal XE. Leonard Hayden Cascade Microtech, Inc. WinCal XE - The Microwave Tool Leonard Hayden Cascade Microtech, Inc. Presentation Outline WinCal XE TM Software application for vector network analyzer probing and measurement Overview of WinCal XE features

More information

ON-WAFER CALIBRATION USING SPACE-CONSERVATIVE (SOLT) STANDARDS. M. Imparato, T. Weller and L. Dunleavy

ON-WAFER CALIBRATION USING SPACE-CONSERVATIVE (SOLT) STANDARDS. M. Imparato, T. Weller and L. Dunleavy ON-WAFER CALIBRATION USING SPACE-CONSERVATIVE (SOLT) STANDARDS M. Imparato, T. Weller and L. Dunleavy Electrical Engineering Department University of South Florida, Tampa, FL 33620 ABSTRACT In this paper

More information

Application Note 5525

Application Note 5525 Using the Wafer Scale Packaged Detector in 2 to 6 GHz Applications Application Note 5525 Introduction The is a broadband directional coupler with integrated temperature compensated detector designed for

More information

FABRICATING AND USING A PCB-BASED TRL PATTERN WITH A CMT VNA

FABRICATING AND USING A PCB-BASED TRL PATTERN WITH A CMT VNA FABRICATING AND USING A PCB-BASED TRL PATTERN WITH A CMT VNA 03/19/2018 Introduction Copper Mountain Technologies provides metrologically sound, lab grade USB VNAs which support advanced calibration techniques,

More information

Infinity Probe Mechanical Layout Rules

Infinity Probe Mechanical Layout Rules Infinity Probe Mechanical Layout Rules APPLICATION NOTE Introduction The explosive growth of smart phones has led to advancements in communications protocols, such as 4G and 5G. This leads to technological

More information

March 4-7, 2018 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive

March 4-7, 2018 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive March 4-7, 2018 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive 2018 BiTS Workshop Image: pilgrims49 / istock COPYRIGHT NOTICE The presentation(s)/poster(s) in this publication comprise the Proceedings

More information

A PROBE TECHNOLOGY FOR 110+ GHZ INTEGRATED CIRCUITS WITH ALUMINUM PADS

A PROBE TECHNOLOGY FOR 110+ GHZ INTEGRATED CIRCUITS WITH ALUMINUM PADS A PROBE TECHNOLOGY FOR 11+ GHZ INTEGRATED CIRCUITS WITH ALUMINUM PADS Amr M. E. Safwat, Mike Andrews, Leonard Hayden, K. Reed Gleason and Eric Strid Cascade Microtech, Inc. 243 NW 26th Avenue, Beaverton,

More information

Agilent Accurate Measurement of Packaged RF Devices. White Paper

Agilent Accurate Measurement of Packaged RF Devices. White Paper Agilent Accurate Measurement of Packaged RF Devices White Paper Slide #1 Slide #2 Accurate Measurement of Packaged RF Devices How to Measure These Devices RF and MW Device Test Seminar 1995 smafilt.tif

More information

Design of Class F Power Amplifiers Using Cree GaN HEMTs and Microwave Office Software to Optimize Gain, Efficiency, and Stability

Design of Class F Power Amplifiers Using Cree GaN HEMTs and Microwave Office Software to Optimize Gain, Efficiency, and Stability White Paper Design of Class F Power Amplifiers Using Cree GaN HEMTs and Microwave Office Software to Optimize Gain, Efficiency, and Stability Overview This white paper explores the design of power amplifiers

More information

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

There is a twenty db improvement in the reflection measurements when the port match errors are removed. ABSTRACT Many improvements have occurred in microwave error correction techniques the past few years. The various error sources which degrade calibration accuracy is better understood. Standards have been

More information

AC-2 Calibration Substrate

AC-2 Calibration Substrate AC-2 Calibration Substrate AC-2 calibration substrate is designed to provide accurate probe tip calibration of MPI TITAN RF probe family with ground-signal-ground (GSG) probe tips configuration and accommodates

More information

Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services

Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services Network Analyzer Measurements In many RF and Microwave measurements the S-Parameters are typically

More information

Keysight Technologies Signal Integrity Tips and Techniques Using TDR, VNA and Modeling

Keysight Technologies Signal Integrity Tips and Techniques Using TDR, VNA and Modeling Keysight Technologies Signal Integrity Tips and Techniques Using, VNA and Modeling Article Reprint This article first appeared in the March 216 edition of Microwave Journal. Reprinted with kind permission

More information

T est POST OFFICE BOX 1927 CUPERTINO, CA TEL E P H ONE (408) FAX (408) ARIES ELECTRONICS

T est POST OFFICE BOX 1927 CUPERTINO, CA TEL E P H ONE (408) FAX (408) ARIES ELECTRONICS G iga T est L abs POST OFFICE BOX 1927 CUPERTINO, CA 95015 TEL E P H ONE (408) 524-2700 FAX (408) 524-2777 ARIES ELECTRONICS BGA SOCKET (0.80MM TEST CENTER PROBE CONTACT) Final Report Electrical Characterization

More information

Coaxial TRL Calibration Kits for Network Analyzers up to 40 GHz

Coaxial TRL Calibration Kits for Network Analyzers up to 40 GHz Focus Microwaves Inc. 277 Lakeshore Road Pointe-Claire, Quebec H9S-4L2, Canada Tel 514-630-6067 Fax 514-630-7466 Product Note No 2 Coaxial TRL Calibration Kits for Network Analyzers up to 40 GHz This note

More information

Design of Impedance Matching Circuit

Design of Impedance Matching Circuit ISSN 2278 0211 (Online) Design of Impedance Matching Circuit Shiwani Shekhar B.Tech Final Year Student, Electronics & Communication Engineering Department J.K. Institute of Applied Physics & Technology,

More information

Design and Demonstration of a Passive, Broadband Equalizer for an SLED Chris Brinton, Matthew Wharton, and Allen Katz

Design and Demonstration of a Passive, Broadband Equalizer for an SLED Chris Brinton, Matthew Wharton, and Allen Katz Introduction Design and Demonstration of a Passive, Broadband Equalizer for an SLED Chris Brinton, Matthew Wharton, and Allen Katz Wavelength Division Multiplexing Passive Optical Networks (WDM PONs) have

More information

Agilent AN Applying Error Correction to Network Analyzer Measurements

Agilent AN Applying Error Correction to Network Analyzer Measurements Agilent AN 287-3 Applying Error Correction to Network Analyzer Measurements Application Note 2 3 4 4 5 6 7 8 0 2 2 3 3 4 Table of Contents Introduction Sources and Types of Errors Types of Error Correction

More information

Aries Kapton CSP socket

Aries Kapton CSP socket Aries Kapton CSP socket Measurement and Model Results prepared by Gert Hohenwarter 5/19/04 1 Table of Contents Table of Contents... 2 OBJECTIVE... 3 METHODOLOGY... 3 Test procedures... 4 Setup... 4 MEASUREMENTS...

More information

Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch

Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch Measurement and Model Results prepared by Gert Hohenwarter 12/14/2015 1 Table of Contents TABLE OF CONTENTS...2 OBJECTIVE...

More information

High Performance Microwave Probes for RF probing

High Performance Microwave Probes for RF probing High Performance Microwave Probes for RF probing Model 40A - Durable RF probe - DC to 40 GHz - Insertion loss less than 0.8 db - Return loss greater than 18 db - Measurement repeatability better than -80db

More information

Evaluation of Package Properties for RF BJTs

Evaluation of Package Properties for RF BJTs Application Note Evaluation of Package Properties for RF BJTs Overview EDA simulation software streamlines the development of digital and analog circuits from definition of concept and estimation of required

More information

Gain Lab. Image interference during downconversion. Images in Downconversion. Course ECE 684: Microwave Metrology. Lecture Gain and TRL labs

Gain Lab. Image interference during downconversion. Images in Downconversion. Course ECE 684: Microwave Metrology. Lecture Gain and TRL labs Gain Lab Department of Electrical and Computer Engineering University of Massachusetts, Amherst Course ECE 684: Microwave Metrology Lecture Gain and TRL labs In lab we will be constructing a downconverter.

More information

ECEN 5014, Spring 2009 Special Topics: Active Microwave Circuits Zoya Popovic, University of Colorado, Boulder

ECEN 5014, Spring 2009 Special Topics: Active Microwave Circuits Zoya Popovic, University of Colorado, Boulder ECEN 5014, Spring 2009 Special Topics: Active Microwave Circuits Zoya opovic, University of Colorado, Boulder LECTURE 3 MICROWAVE AMLIFIERS: INTRODUCTION L3.1. TRANSISTORS AS BILATERAL MULTIORTS Transistor

More information

Configuration of PNA-X, NVNA and X parameters

Configuration of PNA-X, NVNA and X parameters Configuration of PNA-X, NVNA and X parameters VNA 1. S-Parameter Measurements 2. Harmonic Measurements NVNA 3. X-Parameter Measurements Introducing the PNA-X 50 GHz 43.5 GHz 26.5 GHz 13.5 GHz PNA-X Agilent

More information

Aries QFP microstrip socket

Aries QFP microstrip socket Aries QFP microstrip socket Measurement and Model Results prepared by Gert Hohenwarter 2/18/05 1 Table of Contents Table of Contents... 2 OBJECTIVE... 3 METHODOLOGY... 3 Test procedures... 4 Setup... 4

More information

Figure Main frame of IMNLab.

Figure Main frame of IMNLab. IMNLab Tutorial This Tutorial guides the user to go through the design procedure of a wideband impedance match network for a real circuit by using IMNLab. Wideband gain block TQP3M97 evaluation kit from

More information

CALIBRATION TYPES & CONSIDERATIONS

CALIBRATION TYPES & CONSIDERATIONS CALIBRATION TYPES & CONSIDERATIONS 03/12/2018 Introduction One of the most frequently asked questions we receive at Copper Mountain Technologies sales and support departments goes something like this:

More information

Introduction to RF Measurement and Nonideal Components The Vector Network Analyzer UCSB - ECE145A/ECE218A Winter 2007

Introduction to RF Measurement and Nonideal Components The Vector Network Analyzer UCSB - ECE145A/ECE218A Winter 2007 Goals: Introduction to RF Measurement and Nonideal Components The Vector Network Analyzer UCSB - ECE145A/ECE218A Winter 2007 (a) Introduction to the vector network analyzer and measurement of S-parameters.

More information

Antenna Matching Within an Enclosure Part II: Practical Techniques and Guidelines

Antenna Matching Within an Enclosure Part II: Practical Techniques and Guidelines Antenna Matching Within an Enclosure Part II: Practical Techniques and Guidelines By Johnny Lienau, RF Engineer June 2012 Antenna selection and placement can be a difficult task, and the challenges of

More information

Archive 2017 BiTS Workshop- Image: Easyturn/iStock

Archive 2017 BiTS Workshop- Image: Easyturn/iStock Archive September 6-7, 2017 InterContinental Shanghai Pudong Hotel - Shanghai, China Archive 2017 BiTS Workshop- Image: Easyturn/iStock September 6-7, 2017 Archive COPYRIGHT NOTICE This multimedia file

More information

A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm

A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm Chen Shouhong 1, Wang Zhuang 1, Ma Jun 1,*,and Hou Xingna 2 1 School of Electronic Engineering&Automation, Guangxi Key Laboratory

More information

PART MAX2605EUT-T MAX2606EUT-T MAX2607EUT-T MAX2608EUT-T MAX2609EUT-T TOP VIEW IND GND. Maxim Integrated Products 1

PART MAX2605EUT-T MAX2606EUT-T MAX2607EUT-T MAX2608EUT-T MAX2609EUT-T TOP VIEW IND GND. Maxim Integrated Products 1 19-1673; Rev 0a; 4/02 EVALUATION KIT MANUAL AVAILABLE 45MHz to 650MHz, Integrated IF General Description The are compact, high-performance intermediate-frequency (IF) voltage-controlled oscillators (VCOs)

More information

Vector Network Analyzer

Vector Network Analyzer Vector Network Analyzer VNA Basics VNA Roadshow Budapest 17/05/2016 Content Why Users Need VNAs VNA Terminology System Architecture Key Components Basic Measurements Calibration Methods Accuracy and Uncertainty

More information

Microwave Metrology -ECE 684 Spring Lab Exercise T: TRL Calibration and Probe-Based Measurement

Microwave Metrology -ECE 684 Spring Lab Exercise T: TRL Calibration and Probe-Based Measurement ab Exercise T: TR Calibration and Probe-Based Measurement In this project, you will measure the full phase and magnitude S parameters of several surface mounted components. You will then develop circuit

More information

Data Sheet. VMMK GHz E-pHEMT Wideband Amplifier in Wafer Level Package. Description. Features. Specifications (6GHz, 5V, 25mA Typ.

Data Sheet. VMMK GHz E-pHEMT Wideband Amplifier in Wafer Level Package. Description. Features. Specifications (6GHz, 5V, 25mA Typ. VMMK-223.9-11 GHz E-pHEMT Wideband Amplifier in Wafer Level Package Data Sheet Description Avago Technologies has combined its industry leading E-pHEMT technology with a revolutionary wafer level package

More information

Today I would like to present a short introduction to microstrip cross-coupled filter design. I will be using Sonnet em to analyze my planar circuit.

Today I would like to present a short introduction to microstrip cross-coupled filter design. I will be using Sonnet em to analyze my planar circuit. Today I would like to present a short introduction to microstrip cross-coupled filter design. I will be using Sonnet em to analyze my planar circuit. And I will be using our optimizer, EQR_OPT_MWO, in

More information

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3 Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing ystem Product Note E5070/71-3 Introduction The use of differential circuit topologies

More information

High Speed Characterization Report

High Speed Characterization Report SSW-1XX-22-X-D-VS Mates with TSM-1XX-1-X-DV-X Description: Surface Mount Terminal Strip,.1 [2.54mm] Pitch, 13.59mm (.535 ) Stack Height Samtec, Inc. 25 All Rights Reserved Table of Contents Connector Overview...

More information

A 1-W GaAs Class-E Power Amplifier with an FBAR Filter Embedded in the Output Network

A 1-W GaAs Class-E Power Amplifier with an FBAR Filter Embedded in the Output Network A 1-W GaAs Class-E Power Amplifier with an FBAR Filter Embedded in the Output Network Kyle Holzer and Jeffrey S. Walling University of Utah PERFIC Lab, Salt Lake City, UT 84112, USA Abstract Integration

More information

Impedance Matching Techniques for Mixers and Detectors. Application Note 963

Impedance Matching Techniques for Mixers and Detectors. Application Note 963 Impedance Matching Techniques for Mixers and Detectors Application Note 963 Introduction The use of tables for designing impedance matching filters for real loads is well known [1]. Simple complex loads

More information

QUASI-ELLIPTIC MICROSTRIP BANDSTOP FILTER USING TAP COUPLED OPEN-LOOP RESONATORS

QUASI-ELLIPTIC MICROSTRIP BANDSTOP FILTER USING TAP COUPLED OPEN-LOOP RESONATORS Progress In Electromagnetics Research C, Vol. 35, 1 11, 2013 QUASI-ELLIPTIC MICROSTRIP BANDSTOP FILTER USING TAP COUPLED OPEN-LOOP RESONATORS Kenneth S. K. Yeo * and Punna Vijaykumar School of Architecture,

More information

License to Speed: Extreme Bandwidth Packaging

License to Speed: Extreme Bandwidth Packaging License to Speed: Extreme Bandwidth Packaging Sean S. Cahill VP, Technology BridgeWave Communications Santa Clara, California, USA BridgeWave Communications Specializing in 60-90 GHz Providing a wireless

More information

A 6 : 1 UNEQUAL WILKINSON POWER DIVIDER WITH EBG CPW

A 6 : 1 UNEQUAL WILKINSON POWER DIVIDER WITH EBG CPW Progress In Electromagnetics Research Letters, Vol. 8, 151 159, 2009 A 6 : 1 UNEQUAL WILKINSON POWER DIVIDER WITH EBG CPW C.-P. Chang, C.-C. Su, S.-H. Hung, and Y.-H. Wang Institute of Microelectronics,

More information

Including the proper parasitics in a nonlinear

Including the proper parasitics in a nonlinear Effects of Parasitics in Circuit Simulations Simulation accuracy can be improved by including parasitic inductances and capacitances By Robin Croston California Eastern Laboratories Including the proper

More information

Microstrip even-mode half-wavelength SIR based I-band interdigital bandpass filter

Microstrip even-mode half-wavelength SIR based I-band interdigital bandpass filter Indian Journal of Engineering & Materials Sciences Vol. 9, October 0, pp. 99-303 Microstrip even-mode half-wavelength SIR based I-band interdigital bandpass filter Ram Krishna Maharjan* & Nam-Young Kim

More information

Design of a BAW Quadplexer Module Using NI AWR Software

Design of a BAW Quadplexer Module Using NI AWR Software Application Note Design of a BAW Quadplexer Module Using NI AWR Software Overview With the development of the LTE-Advanced and orthogonal frequency division multiple access (OFDMA) techniques, multiple

More information

Range Considerations for RF Networks

Range Considerations for RF Networks TI Technology Days 2010 Range Considerations for RF Networks Richard Wallace Abstract The antenna can be one of the most daunting components of wireless designs. Most information available relates to large

More information

Aries CSP microstrip socket Cycling test

Aries CSP microstrip socket Cycling test Aries CSP microstrip socket Cycling test RF Measurement Results prepared by Gert Hohenwarter 2/18/05 1 Table of Contents TABLE OF CONTENTS... 2 OBJECTIVE... 3 METHODOLOGY... 3 Test procedures... 6 Setup...

More information

High Speed Characterization Report

High Speed Characterization Report QTH-030-01-L-D-A Mates with QSH-030-01-L-D-A Description: High Speed Ground Plane Header Board-to-Board, 0.5mm (.0197 ) Pitch, 5mm (.1969 ) Stack Height Samtec, Inc. 2005 All Rights Reserved Table of Contents

More information

The Infinity Probe for On-Wafer Device Characterization and Modeling to 110 GHz

The Infinity Probe for On-Wafer Device Characterization and Modeling to 110 GHz Q & A Innovating Test Technologies The Infinity Probe for On-Wafer Device Characterization and Modeling to 110 GHz Why is this announcement important? INFINITY-QA-1102 Data subject to change without notice

More information

MODIFIED MILLIMETER-WAVE WILKINSON POWER DIVIDER FOR ANTENNA FEEDING NETWORKS

MODIFIED MILLIMETER-WAVE WILKINSON POWER DIVIDER FOR ANTENNA FEEDING NETWORKS Progress In Electromagnetics Research Letters, Vol. 17, 11 18, 2010 MODIFIED MILLIMETER-WAVE WILKINSON POWER DIVIDER FOR ANTENNA FEEDING NETWORKS F. D. L. Peters, D. Hammou, S. O. Tatu, and T. A. Denidni

More information

Compact Distributed Phase Shifters at X-Band Using BST

Compact Distributed Phase Shifters at X-Band Using BST Integrated Ferroelectrics, 56: 1087 1095, 2003 Copyright C Taylor & Francis Inc. ISSN: 1058-4587 print/ 1607-8489 online DOI: 10.1080/10584580390259623 Compact Distributed Phase Shifters at X-Band Using

More information

GrypperG Contact 0.4 Pitch, 0.25 Ball Diameter 0.5 Pitch, 0.25 Ball Diameter RF CHARACTERIZATION SUMMARY TEST OBJECTIVE

GrypperG Contact 0.4 Pitch, 0.25 Ball Diameter 0.5 Pitch, 0.25 Ball Diameter RF CHARACTERIZATION SUMMARY TEST OBJECTIVE RF HARATERIZATION SUMMARY GrypperG4 14468-14 ontact.4 Pitch,.25 Ball Diameter.5 Pitch,.25 Ball Diameter TEST OBJETIVE The objective of this report is to determine the RF transmission characteristics of

More information

Data Sheet. VMMK to 4 GHz GaAs High Linearity LNA in Wafer Level Package. Features. Description. Specifications (Vdd = 3.

Data Sheet. VMMK to 4 GHz GaAs High Linearity LNA in Wafer Level Package. Features. Description. Specifications (Vdd = 3. VMMK-243 2 to 4 GHz GaAs High Linearity LNA in Wafer Level Package Data Sheet Description Avago s VMMK-243 is an easy-to-use, high linearity low noise amplifier in a miniaturized wafer level package (WLP).

More information

Extraction of Broadband Error Boxes for Microprobes and Recessed Probe Launches for Measurement of Printed Circuit Board Structures

Extraction of Broadband Error Boxes for Microprobes and Recessed Probe Launches for Measurement of Printed Circuit Board Structures Extraction of Broadband Error Boxes for Microprobes and Recessed Probe Launches for Measurement of Printed Circuit Board Structures, Renato Rimolo-Donadio, Christian Schuster Institut für TU Hamburg-Harburg,

More information

MPI Probe Selection Guide

MPI Probe Selection Guide MPI Probe Selection Guide With a critical understanding of the numerous measurement challenges associated with today s RF applications, MPI Corporation has developed TITAN RF Probes, a product series specifically

More information

A Simplified QFN Package Characterization Technique

A Simplified QFN Package Characterization Technique Slide -1 A Simplified QFN Package Characterization Technique Dr. Eric Bogatin and Trevor Mitchell Bogatin Enterprises Dick Otte, President, Promex 8/1/10 Slide -2 Goal of this Project Develop a simple

More information

Data Sheet. VMMK GHz Positive Gain Slope Low Noise Amplifier in SMT Package. Features. Description

Data Sheet. VMMK GHz Positive Gain Slope Low Noise Amplifier in SMT Package. Features. Description VMMK-3603 1-6 GHz Positive Gain Slope Low Noise Amplifier in SMT Package Data Sheet Description The VMMK-3603 is a small and easy-to-use, broadband, positive gain slope low noise amplifier operating in

More information

SINGLE & DOUBLE STUB MATCHING TECHNIQUES

SINGLE & DOUBLE STUB MATCHING TECHNIQUES SINGLE & DOUBLE STUB MATCHING TECHNIQUES PROF.MADHURI MAHENDRA PATIL Department of Electronics and Telecommunication PRAVIN PATIL DIPLOMA COLLEGE, BHAYANDAR-401105 Abstract: The purpose of this paper is

More information

ECE 4265/6265 Laboratory Project 7 Network Analyzer Calibration

ECE 4265/6265 Laboratory Project 7 Network Analyzer Calibration ECE 4265/6265 Laboratory Project 7 Network Analyzer Calibration Objectives The purpose of this lab is to introduce the concepts of calibration and error correction for microwave s-parameter measurements.

More information

Wide-Band Two-Stage GaAs LNA for Radio Astronomy

Wide-Band Two-Stage GaAs LNA for Radio Astronomy Progress In Electromagnetics Research C, Vol. 56, 119 124, 215 Wide-Band Two-Stage GaAs LNA for Radio Astronomy Jim Kulyk 1,GeWu 2, Leonid Belostotski 2, *, and James W. Haslett 2 Abstract This paper presents

More information

Methodology for MMIC Layout Design

Methodology for MMIC Layout Design 17 Methodology for MMIC Layout Design Fatima Salete Correra 1 and Eduardo Amato Tolezani 2, 1 Laboratório de Microeletrônica da USP, Av. Prof. Luciano Gualberto, tr. 3, n.158, CEP 05508-970, São Paulo,

More information

APPLICATION NOTE FOR PA.710.A ANTENNA INTEGRATION

APPLICATION NOTE FOR PA.710.A ANTENNA INTEGRATION APPLICATION NOTE FOR PA.710.A ANTENNA INTEGRATION APN-13-8-005/B/NB Page 1 of 17 1. TABLE OF CONTENTS 1. TABLE OF CONTENTS... 2 2. BASICS... 3 3. APPLICATIONS... 4 4. IMPEDANCE... 4 5. BANDWIDTH... 4 6.

More information

Wafer-scale 3D integration of silicon-on-insulator RF amplifiers

Wafer-scale 3D integration of silicon-on-insulator RF amplifiers Wafer-scale integration of silicon-on-insulator RF amplifiers The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation As Published

More information

Lecture 4. Maximum Transfer of Power. The Purpose of Matching. Lecture 4 RF Amplifier Design. Johan Wernehag Electrical and Information Technology

Lecture 4. Maximum Transfer of Power. The Purpose of Matching. Lecture 4 RF Amplifier Design. Johan Wernehag Electrical and Information Technology Johan Wernehag, EIT Lecture 4 RF Amplifier Design Johan Wernehag Electrical and Information Technology Design of Matching Networks Various Purposes of Matching Voltage-, Current- and Power Matching Design

More information

Aries Kapton CSP socket Cycling test

Aries Kapton CSP socket Cycling test Aries Kapton CSP socket Cycling test RF Measurement Results prepared by Gert Hohenwarter 10/21/04 1 Table of Contents TABLE OF CONTENTS... 2 OBJECTIVE... 3 METHODOLOGY... 3 Test procedures... 5 Setup...

More information

Research Article A Reconfigurable Coplanar Waveguide Bowtie Antenna Using an Integrated Ferroelectric Thin-Film Varactor

Research Article A Reconfigurable Coplanar Waveguide Bowtie Antenna Using an Integrated Ferroelectric Thin-Film Varactor Antennas and Propagation Volume 212, Article ID 24919, 6 pages doi:1.1155/212/24919 Research Article A Reconfigurable Coplanar Waveguide Bowtie Antenna Using an Integrated Ferroelectric Thin-Film Varactor

More information

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES Frequency range: 9 khz - 6.5 or 8.5 GHz Measured parameters: S11, S12, S21, S22 Wide output power adjustment range: -50 dbm to +5 dbm

More information

High Frequency Passive Components

High Frequency Passive Components EECS 142 Laboratory #1 High Frequency Passive Components Prof. A. M. Niknejad and Dr. Joel Dunsmore University of California Berkeley, CA 94720 August 1, 2008 1 SMT Component SMA Connector 1 Introduction

More information

High Rejection BPF for WiMAX Applications from Silicon Integrated Passive Device Technology

High Rejection BPF for WiMAX Applications from Silicon Integrated Passive Device Technology High Rejection BPF for WiMAX Applications from Silicon Integrated Passive Device Technology by Kai Liu, Robert C Frye* and Billy Ahn STATS ChipPAC, Inc, Tempe AZ, 85284, USA, *RF Design Consulting, LLC,

More information

Narrowband Microstrip Filter Design With NI AWR Microwave Office

Narrowband Microstrip Filter Design With NI AWR Microwave Office Narrowband Microstrip Filter Design With NI AWR Microwave Office Daniel G. Swanson, Jr. DGS Associates, LLC Boulder, CO dan@dgsboulder.com www.dgsboulder.com Narrowband Microstrip Filters There are many

More information

PRODUCT APPLICATION NOTES

PRODUCT APPLICATION NOTES Extending the HMC189MS8 Passive Frequency Doubler Operating Range with External Matching General Description The HMC189MS8 is a miniature passive frequency doubler in a plastic 8-lead MSOP package. The

More information

"Natural" Antennas. Mr. Robert Marcus, PE, NCE Dr. Bruce C. Gabrielson, NCE. Security Engineering Services, Inc. PO Box 550 Chesapeake Beach, MD 20732

Natural Antennas. Mr. Robert Marcus, PE, NCE Dr. Bruce C. Gabrielson, NCE. Security Engineering Services, Inc. PO Box 550 Chesapeake Beach, MD 20732 Published and presented: AFCEA TEMPEST Training Course, Burke, VA, 1992 Introduction "Natural" Antennas Mr. Robert Marcus, PE, NCE Dr. Bruce C. Gabrielson, NCE Security Engineering Services, Inc. PO Box

More information

A COMPACT DUAL-BAND POWER DIVIDER USING PLANAR ARTIFICIAL TRANSMISSION LINES FOR GSM/DCS APPLICATIONS

A COMPACT DUAL-BAND POWER DIVIDER USING PLANAR ARTIFICIAL TRANSMISSION LINES FOR GSM/DCS APPLICATIONS Progress In Electromagnetics Research Letters, Vol. 1, 185 191, 29 A COMPACT DUAL-BAND POWER DIVIDER USING PLANAR ARTIFICIAL TRANSMISSION LINES FOR GSM/DCS APPLICATIONS T. Yang, C. Liu, L. Yan, and K.

More information

Analysis and design of lumped element Marchand baluns

Analysis and design of lumped element Marchand baluns Downloaded from orbit.dtu.d on: Mar 14, 218 Analysis and design of lumped element Marchand baluns Johansen, Tom Keinice; Krozer, Vitor Published in: 17th International Conference on Microwaves, Radar and

More information

California Eastern Laboratories

California Eastern Laboratories California Eastern Laboratories AN143 Design of Power Amplifier Using the UPG2118K APPLICATION NOTE I. Introduction Renesas' UPG2118K is a 3-stage 1.5W GaAs MMIC power amplifier that is usable from approximately

More information

Measurements with the LeCroy SPARQ and Cascade Microtech Probes Using WinCal XE Calibrations

Measurements with the LeCroy SPARQ and Cascade Microtech Probes Using WinCal XE Calibrations Measurements with the LeCroy SPARQ and Cascade Microtech Probes Using WinCal XE Calibrations LeCroy Corporation and Cascade Microtech APPLICATION NOTE Introduction Measurements on two printed circuit boards

More information

AN ABSTRACT OF THE THESIS OF. Kyle M. Webb for the degree of Master of Science in. Electrical and Computer Engineering presented on June 27, 2005.

AN ABSTRACT OF THE THESIS OF. Kyle M. Webb for the degree of Master of Science in. Electrical and Computer Engineering presented on June 27, 2005. AN ABSTRACT OF THE THESIS OF Kyle M. Webb for the degree of Master of Science in Electrical and Computer Engineering presented on June 27, 2005. Title: A Test Fixture and Deembedding Procedure for High-Frequency

More information

Application Note 5012

Application Note 5012 MGA-61563 High Performance GaAs MMIC Amplifier Application Note 5012 Application Information The MGA-61563 is a high performance GaAs MMIC amplifier fabricated with Avago Technologies E-pHEMT process and

More information

Amateur Extra Manual Chapter 9.4 Transmission Lines

Amateur Extra Manual Chapter 9.4 Transmission Lines 9.4 TRANSMISSION LINES (page 9-31) WAVELENGTH IN A FEED LINE (page 9-31) VELOCITY OF PROPAGATION (page 9-32) Speed of Wave in a Transmission Line VF = Velocity Factor = Speed of Light in a Vacuum Question

More information

Comparative analysis of single-band Wilkinson Power Dividers

Comparative analysis of single-band Wilkinson Power Dividers IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-issn: 2278-2834,p- ISSN: 2278-8735.Volume 9, Issue 3, Ver. II (May - Jun. 2014), PP 65-70 Comparative analysis of single-band Wilkinson

More information

Leveraging High-Accuracy Models to Achieve First Pass Success in Power Amplifier Design

Leveraging High-Accuracy Models to Achieve First Pass Success in Power Amplifier Design Application Note Leveraging High-Accuracy Models to Achieve First Pass Success in Power Amplifier Design Overview Nonlinear transistor models enable designers to concurrently optimize gain, power, efficiency,

More information

This article describes the design of a multiband,

This article describes the design of a multiband, A Low-Noise Amplifier for 2 GHz Applications Using the NE334S01 Transistor By Ulrich Delpy NEC Electronics (Europe) This article describes the design of a multiband, low-noise amplifier (LNA) using the

More information

Design and Analysis of Novel Compact Inductor Resonator Filter

Design and Analysis of Novel Compact Inductor Resonator Filter Design and Analysis of Novel Compact Inductor Resonator Filter Gye-An Lee 1, Mohamed Megahed 2, and Franco De Flaviis 1. 1 Department of Electrical and Computer Engineering University of California, Irvine

More information

Accurate Simulation of RF Designs Requires Consistent Modeling Techniques

Accurate Simulation of RF Designs Requires Consistent Modeling Techniques From September 2002 High Frequency Electronics Copyright 2002, Summit Technical Media, LLC Accurate Simulation of RF Designs Requires Consistent Modeling Techniques By V. Cojocaru, TDK Electronics Ireland

More information

Circuit Characterization with the Agilent 8714 VNA

Circuit Characterization with the Agilent 8714 VNA Circuit Characterization with the Agilent 8714 VNA By: Larry Dunleavy Wireless and Microwave Instruments University of South Florida Objectives 1) To examine the concepts of reflection, phase shift, attenuation,

More information

Design of Low Noise Amplifier Using Feedback and Balanced Technique for WLAN Application

Design of Low Noise Amplifier Using Feedback and Balanced Technique for WLAN Application Available online at www.sciencedirect.com Procedia Engineering 53 ( 2013 ) 323 331 Malaysian Technical Universities Conference on Engineering & Technology 2012, MUCET 2012 Part 1- Electronic and Electrical

More information

NATIONAL UNIVERSITY of SINGAPORE

NATIONAL UNIVERSITY of SINGAPORE NATIONAL UNIVERSITY of SINGAPORE Faculty of Engineering Electrical & Computer Engineering Department EE3104 Introduction to RF and Microwave Systems & Circuits Experiment 1 Familiarization on VNA Calibration

More information

Aries Center probe CSP socket Cycling test

Aries Center probe CSP socket Cycling test Aries Center probe CSP socket Cycling test RF Measurement Results prepared by Gert Hohenwarter 10/27/04 1 Table of Contents TABLE OF CONTENTS... 2 OBJECTIVE... 3 METHODOLOGY... 3 Test procedures... 5 Setup...

More information

Design and Simulation of Folded Arm Miniaturized Microstrip Low Pass Filter

Design and Simulation of Folded Arm Miniaturized Microstrip Low Pass Filter 813 Design and Simulation of Folded Arm Miniaturized Microstrip Low Pass 1 Inder Pal Singh, 2 Praveen Bhatt 1 Shinas College of Technology P.O. Box 77, PC 324, Shinas, Oman 2 Samalkha Group of Institutions,

More information

Using Accurate Component Models to Achieve First-Pass Success in Filter Design

Using Accurate Component Models to Achieve First-Pass Success in Filter Design Application Example Using Accurate Component Models to Achieve First-Pass Success in Filter Design Overview Utilizing models that include component and printed circuit board (PCB) parasitics in place of

More information

SAW Filter PCB Layout

SAW Filter PCB Layout SAW Filter PCB Layout by Allan Coon Director, Filter Product Marketing Murata Electronics North America, c. 1999 troduction The performance of surface acoustic wave (SAW) filters depends on a number of

More information

Design of Microstrip Coupled Line Bandpass Filter Using Synthesis Technique

Design of Microstrip Coupled Line Bandpass Filter Using Synthesis Technique Design of Microstrip Coupled Line Bandpass Filter Using Synthesis Technique 1 P.Priyanka, 2 Dr.S.Maheswari, 1 PG Student, 2 Professor, Department of Electronics and Communication Engineering Panimalar

More information