Universal current sensitive RCCBs B type and F type
|
|
- Harvey Harper
- 6 years ago
- Views:
Transcription
1 GE Industrial Solutions Universal current sensitive RCCBs B type and F type Ultimate protection of people and equipment ge.com/ex/industrialsolutions
2 Type B applications Controllers and variable speed drives Battery chargers and inverters Frequency converters Photovoltaic systems, a.c side Charging stations for electric vehicles Installation in general where we can expect d.c. smooth direct residual currents Variable speed machine tools UPS, Computer Data Centers Elevator controls Cranes of all kinds Test set-ups in laboratories Backed-up power supplies Electronic equipment on construction sites
3 Residual Current Circuit Breakers Residual Current Protection Devices Types of Wave form detected by RCCBs and classification RCCBs Type AC Type A-Ai Type F Type B Waveform definition Current waveform Tripping current Sine wave 0,5 to 1 IΔn Pulsating half wave 0,35 to 1,4 IΔn Pulsating 90º/135º wave Pulsating Half wave + diret current (6mA) Pulsating Half wave + diret current (10mA) Current delay angle 90º: 0,25 to 1,4 Iδn Current delay angle 135º: 0,11 to 1,4 IΔn max. 1,4 IΔn+6mA max. 1,4 IΔn+10mA Composite wave 0,5 to 1,4 IΔn General view High frequency (up to 1KHz) Current Frequency 150Hz 0,5 to 2,4 IΔn Current Frequency 400Hz 0,5 to 6 IΔn Current Frequency 1000Hz 1 to 14 IΔn Two phase rectified full wave Three phase rectified full wave Direct current 0,5 to 2 IΔn Discover advantages: Type F Offer the same range of protection and functionality as a Type A RCD; this means that release with sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are capable of detecting residual currents from mixed frequencies of up to 1000 Hz, which can often occur on the outgoing feeder side of singlephase frequency converters. This prevents undesirable interruptions to the electrical supply if, for example, pulsed leakage currents of up to ten milliseconds occur at activation of filter capacitors. Type B In adition to release residual current waveforms of type A, B type RCCBs are used to detect smooth DC residual currents. B Type RCCBs are recommended for use with EV Charge and drives and inverters for supplying motors for pumps, lifts, textile machines, machine tools since they recognise a continuous fault current with low level ripple. Type BS Release residual current waveforms of type B with time delay. Type AC: Release with sinusoidal currents which occur suddenly or slowly rise in magnitude. Type A-Ai: Release with sinusoidal currents and also with pulsating direct current which occur suddenly or slowly rise in magnitude. Type S-Si (type A-Ai): Time delay release with sinusoidal currents and also with pulsating direct current which occur suddenly or slowly rise in magnitude. 3
4 RCCBs RCCBs - Residual Current Circuit Breakers RCCB with overcurrent protection Add-on devices Series FP-FIP Performance EN 62423/ VDE Type B Type BS FP FIP (3) Auxiliaries (1) Motor operator (2) Rated current In (A) FP: 16, 25, 40, 63, 80; FIP: 100, 125 Residual current I (ma) 30, 100, 300, 500 Rated Voltage AC Un (V) 2P: 230 4P: 230/400 Minimum operating voltage U min 30 ma (V) 2P: 160 4P: ,300,500 ma (V) 2P: 117 4P: 205 Mechanical/electrical endurange FP: /10.000; FIP>5000 Tropicalisation acc. to EN/IEC /2-30 and DIN %RH at 55ºC Terminal capacity flexible/rigid cable (mm 2 ) FP: 1,5-50; FIP: 1,5-50 Poles FP: 2, 4; FIP: 4 Nuisance tripping resistance 3000A 8/20 msc Ambient temperature (ºC) -25 up to 40 Weight (g) 2P 340 (g) 4P FP: 420; FIP: 500 Short-circuit capacity (1) Series CA - Tele L - Tele U - PBS - TeleREC Plus (2) Only at right side end of the extreme pin busbar (3) Only FIPH model Wiring Acc. To EN/IEC Making and Breaking capacity Im=500A from 16A up to 40A Im=10In from 63 up to 80A Im=1000A (100A) Im=1250A (125A) Residual making and braking capacity I m=50in from 16A up to 40A I m=10in from 63A up to 80A I m=1000 (100A) I m=1250 (125A) Short-circuit capacity Inc=10000A at 230/400V fuse 80A gg Serie FP - Type B Serie FP - Type B 1 N N 2 N N 4
5 Series FP Type B 30 ma 100 ma 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Pack 16 FPB 2 16/ FPB 2 16/ FPB 2 16/ FPB 2 16/ FPB 2 25/ FPB 2 25/ FPB 2 25/ FPB 2 25/ FPB 2 40/ FPB 2 40/ FPB 2 40/ FPB 2 40/ FPB 2 63/ FPB 2 63/ FPB 2 63/ FPB 2 63/ FPB 2 80/ FPB 2 80/ FPB 2 80/ FPB 2 80/ /3 16 FPB 4 16/ FPB 4 16/ FPB 4 16/ FPB 4 16/ FPB 4 25/ FPB 4 25/ FPB 4 25/ FPB 4 25/ FPB 4 40/ FPB 4 40/ FPB 4 40/ FPB 4 40/ FPB 4 63/ FPB 4 63/ FPB 4 63/ FPB 4 63/ FPB 4 80/ FPB 4 80/ FPB 4 80/ FPB 4 80/ Series FIP Type B 1/3 Series FP-FIP 30 ma 100 ma 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Pack 100 FIPB4100/ FIPB4100/ FIPB4100/ FIPB4100/ FIPB4125/ FIPB4125/ FIPB4125/ FIPB4125/ Series FIP Type BS 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Pack 40 FIPBS440/ FIPBS440/ FIPBS463/ FIPBS463/ FIPBS480/ FIPBS480/ FIPBS4100/ FIPBS4100/ FIPBS4125/ FIPBS4125/ Dimensions Series FP Series FIP 5
6 RCCBs RCCBs - Residual Current Circuit Breakers RCCB with overcurrent protection Add-on devices FP Series FP Performance EN/IEC EN 62423/ VDE Type F Auxiliaries (1) Motor operator (2) (1) Series CA - Tele L - Tele U - PBS - TeleREC Plus (2) Only at right side end of the extreme pin busbar Rated current In (A) 25, 40, 63, 80 Residual current I (ma) 30 Rated Voltage AC Un (V) 2P: 240 4P: 240/415 Minimum operating voltage U min 30 ma (V) 2P: 160 4P: 258 Mechanical/electrical endurange / Tropicalisation acc. to EN/IEC /2-30 and DIN %RH at 55ºC Terminal capacity flexible/rigid cable (mm 2 ) 1,5-50 (1,5-50) Poles 2, 4 (4) Nuisance tripping resistance 3000A 8/20 msc Ambient temperature (ºC) -25 up to 40 Weight (g) 2P 220 (g) 4P 385 Short-circuit capacity Acc. To EN/IEC Making and Breaking capacity Im=500A from 16A up to 40A Im=10In from 63 up to 80A Im=1000A (100A) Im=1250A (125A) Residual making and braking capacity I m=500 from 16A up to 80A I m=10in from 63A up to 80A Short-circuit capacity Inc=10000A at 240/415V (230V/400V) fuse 80A gg Available soon 6
7 Series FP Type F 30 ma In (A) Cat. No. Ref. No. Pack 25 FPF 2 25/ FPF 2 40/ FPF 2 63/ FPF 2 80/ /6 25 FPF 4 25/ FPF 4 40/ FPF 4 63/ FPF 4 80/ /3 Series FP Wiring Serie FP - Type F Serie FP - Type F 1 /2 3 /4 1/2 3/4 5/6 N 2 /1 4 /3 2/1 4/3 6/5 N Dimensions 7
8 RCCBs Auxiliaries for FP RCCB with overcurrent protection Series CA Function Cat. No. Ref. No. Pack 1/2 mod. H CA H S/H CA S/H S/H CA S/H G golden contacts Series CB Function Cat. No. Ref. No. Pack 1/2 mod. SH/HH CB SH/HH-R (1) /40 1/40 (1) Coupling on the right Wiring Serie CA Serie CB H Auxiliaries for FIP 100A and 125 A Contacts Cat. No. Ref. No. Pack 1/2 mod. 1NO+1NC FIPH
9 Add-on Devices for FP Tele MP - Motor operator Voltage Cat. No. Ref. No. Pack 3 mod. AC 230V TELE MP Tele L - Shunt trip Voltage Cat. No. Ref. No. Pack AC 24-60V DC 24-48V TELE L AC V DC V TELE L Auxiliary - Add-on Devices Tele U - Undervoltage release Voltage Cat. No. Ref. No. Pack AC 240V TELE U AC/DC 12V TELE U AC/DC 24V TELE U AC/DC 48V TELE U PBS - Panel board switch Cat. No. Ref. No. Pack 1/2 mod. PBS Wiring Tele MP Tele L Tele U PBS 9
10 RCCBs Technical data RCCB with overcurrent protection Series FP Type B FIP Type B-BS FP Type F Standards EN 62423/ VDE EN 62423/ VDE EN 62423/ VDE Magnetic tripping characteristics Residual tripping characteristic B BS F Tripping time at I Δn Instantaneous ms <300 <300 <300 Selective ms - >130 - Rated current A 16, 25, 40, 63, 80 B: 100,125; BS:40,63,80,100,125 25, 40, 63, 80 Rated residual current I Δn ma 30, 100, 300, 500 B: 30,100,300,500; BS: 300, Calibration temperature ºC Number of poles versus modules 2P = 4 mod.; 4P = 4 mod. 4P = 4 mod. 2P = 2 mod.; 4P = 4 mod. Rated voltage Un 2P AC V P AC - - 4P AC V 230/ / Frequency Hz 50/60 50/60 50/60 Maximum service voltage Ubmax V 2P=265/4P=460 4P=440 2P=265/4P=455 Minimum service voltage Ubmin (30 ma) V 2P=160/4P=258 4P=260 2P=160/4P=258 Minimum service voltage Ubmin (100, 300, 500 ma) V 2P=117/4P=205 4P=260 - Minimum voltage for leakage protection Voltage independent Voltage independent Voltage independent Power supply Top/Bottom Top/Bottom Top/Bottom Energy limiting class Rated making and breaking capacity (Im) A 500 (or 10In) (or 10In) Residual making and breaking capacity (IΔ m) A 500 (or 10In) 100A=1000; 125A= (or 10In) Conditional short-circuit capacity (Inc) A fuse 80A glgg fuse 80A glgg fuse 80A glgg Conditional residual short-circuit capacity (IΔ c) A fuse 80A glgg fuse 80A glgg fuse 80A glgg Rated Short-circuit capacity (Icn) A Grid distance (safety distance between two devices) Isolator application yes yes yes Insulation degree Insulation voltage V(DC) Shock voltage (1.2/50μs) kv 6 6 Insulation resistance Mohm Dielectric strength V Shock resistance (in x, y, z direction) (EN/IEC 60077/16.3) 40g 18 shocks 5ms 20g /20ms 40g 18 shocks 5ms Vibration resistance (in x, y, z direction) (EN/IEC ) 1,5g. 30 min, 0..80Hz 5g, 30 min,0 80Hz 1,5g. 30 min, 0..80Hz Endurance electrical at Un, In > mechanical at Un, In > Protection degree (outside/inside electrical enclosure with door) IP20/IP40 IP20/IP40 IP20/IP40 Self extinguish degree (according to UL94) V2 - V2 Tropicalisation (according to EN/IEC , DIN 40046) ºC/RH 55/95% 55/97% 55/95% Pollution degree (acc. EN/IEC ) Operating temperature -25ºC +40ºC -25ºC +40ºC -25ºC +40ºC Storage temperature -25ºC +70ºC -25ºC +70ºC -25ºC +70ºC Terminals capacity Rigid cable min/max (top) mm 2 1,5/50 (1,5/35) 1,5/50 1,5/50 (1,5/35) Flexible cable min/max (top) mm 2 1,5/35 (1,5/25) 1,5/50 1,5/35 (1,5/25) Rigid cable min/max (bottom) mm 2 1,5/50 (1,5/35) 1,5/50 1,5/50 (1,5/35) Flexible cable min/max (bottom) mm 2 1,5/35 (1,5/25) 1,5/50 1,5/35 (1,5/25) Torque Top/Bottom Nm 5/5 3/mrt 5/5 Add-on devices (side add-on) Auxiliary contacts yes yes yes Tele U yes no yes Tele L yes no yes Tele M yes no yes PBS yes no yes Busbars systems Pin yes yes yes Fork yes yes yes # Poles Dimensions (HxDxW) 86x70xW /72 Weight 2P=340 ; 4P=420 4P=500 2P=220 ; 4P=385 Package 1/3 3 2P=1/6; 4P=1/3 Approvals VDE VDE - CE-marking yes yes yes 10
11
12 GE Industrial Solutions is a first class global supplier of low and medium voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide. Belgium GE Industrial Belgium Nieuwevaart 51 B-9000 Gent Tel. +32 (0) Finland Kuortaneenkatu 2 FI Helsinki Tel (0) France Paris Nord 2 13, rue de la Perdrix F Roissy CDG Cédex Tel. +33 (0) Germany Robert-Bosch Str. 3 D Hürth-Efferen Tel. +49 (0) 2233/ Hungary GE Hungary Kft. Vaci ut H-1139 Budapest Tel Italy Centro Direzionale Colleoni Via Paracelso 16 Palazzo Andromeda B1 I Agrate Brianza (MB) Tel Netherlands Parallelweg 10 Nl-7482 CA Haaksbergen Tel. +31 (0) Poland GE Power Controls Ul. Towarowa 25A, Ip Warszawa Tel Ul. Leszczyńska Bielsko-Biała Tel Russia 27/8, Electrozavodskaya street Moscow, Tel South Africa Unit 4, 130 Gazelle Avenue Corporate Park Midrand 1685 P.O. Box Wendywood 2144 Tel Spain GE POWER CONTROLS IBÉRICA, S.L. Calle Miño 122 Naves E-F Polígono Industrial Santa Margarita Terrassa (Barcelona) Tel United Arab Emirates Injaz Building, 3rd Floor Dubai Internet City PO Box 11549, Dubai Tel United Kingdom 2 The Arena, Downshire Way Bracknell, Berkshire RG12 1PU Tel. +44 (0) ge.com/ex/industrialsolutions Ref. R/2536/E/EX 1.0 Ed. 05/15 * Trademark of General Electric Company Copyright 2015
Modular DIN-rail devices
GE Industrial Solutions Modular DI-rail devices Series K ex.geindustrial.com Modulair DI-rail protection.1 Line protection.2 Selection table of Ms.3 Technical data.4 Short-circuit capacity of Ms.7 Series
More informationPage 13-2 Page Page 13-7
Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,
More informationResidual Current Operated Circuit-Breakers (RCCBs)
Product Overview Residual Current Operated Circuit-Breakers (RCCBs) Residual current operated circuit-breakers Number of poles Rated current A Rated residual current ma MW Auxiliary contacts can be mounted
More informationTechnical features table for miniature circuit-breakers SH 200 Series
Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution
More informationResidual Current Operated Circuit-Breakers (RCCBs)
Product overview Residual Current Operated C ircuit-breakers (RCCBs) Number of poles Rated fault current I n ma Rated current I n A MW Auxiliary switches can be mounted (Type A) (Type B) 5SM1and 5SM3 RCCBs
More informationBtdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION
More informationCircuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications
Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationComponents for Marine applications
Components for Marine applications Imagination GE imagination at work. at work v. 10-2015 GE Industrial Solutions Leading the future of electrification GE Industrial Solutions is leading the future of
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationSM2000 TECHNICAL DESCRIPTION
SM2000 TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The SM2000 module is a high frequency switch mode rectifier. It converts the single phase AC line voltage into an isolated DC voltage. It can be used
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationBtdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION
More informationHigh-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40
High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40 C O M P O N E N T S The UR26, UR36 & UR40 are DC high-speed current limiting air Circuit-Breakers, trip free, single pole, bi-directional,
More informationV2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...
P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector
More information90 ReStart AUTOMATIC RECLOSING DEVICES
RESTART WITH AUTOTEST Technical data TYPE ReStart with Autotest 2P ReStart with Autotest PRO 2P ReStart with Autotest PRO 4P Electrical characteristics Standards: EN 50557, EN 61008-1 Distribution system:
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationSwitched mode power supply for DIN rail mounting type SMP21 DC24V/10A
Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More informationAdd-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.
More informationFIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented
Doepke The experts in residual current protection technology Residual Current Circuit-Breakers it- r with Overcurrent Protection (RCBO) FIB / FIC» effi cient» reliable» fl exible» future-oriented Doepke
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from
More informationPower supply CP-T 48/5.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationContactors and Contactor Assemblies
s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation
More informationResidual current circuit breakers (RCCBs)
Residual current circuit breakers (RCCBs) Description Automatically trips in event of earth leakage fault Provides protection against direct & indirect contact with live parts Technical data IS 12640-1,
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationEN 50178, IEC
Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230
More informationtechnical information
technical information protection devices 192 circuit protection principle 194 circuit breakers characteristics 200 moulded case circuit breakers (MCCB) 205 prospective fault current 208 selectivity and
More informationPhase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement
More informationSwitched mode power supply for DIN rail mounting type SMP23 DC24V/40A
Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and
More information38 Series - Relay Interface Modules A
Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationLow Pass Harmonic Filters
Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_02_D_XXEN/11.2018
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationCircuit protection devices
Circuit protection devices MCBs, RCCBs, RCBO, ELR, surge arresters, fuse carriers, complete range of auxiliaries, busbars and connectors EA 2002/1 Welcome to the new edition of our general catalogue For
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationPower supply CP-D 24/1.3
2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_00_D_XXEN/05.2015
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationTHE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES P. 20-21 DX³ - MCB AC Application upto 63 A MCBs P. 23 DX³ - 25 ka MCB from 6 A to 125 A Isolator RCCB & RCBOs
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationAC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300
Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application
More informationACS600, ACS800. Installation Guide
ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60 2003 ABB Oy. All Rights Reserved. 3AFE 58933368
More informationThree-phase monitoring relay CM-PVE
Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012
More informationTheta 20A / 20V. Technical Data Sheet. Special Features
Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in
More informationNIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A
High performance circuit breaker mcb and combined mcb with remote controls LV Distribution Products 2-63A Mini motorized circuit breaker The mini-series of motorized circuit breakers operates both locally
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationElectronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E
More informationElectronic circuit breaker ESS30-Sxxx-DC24V
Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
Current Transducer CTSR 0.6-TP/SP2 I PRN = 600 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Features
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationElectronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
More informationEnergy Management Energy Meter Type EM110
Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit
More information38 Series - Relay interface modules A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationCOUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS
COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS Operating instructions EN Contents 1. Documentation...3 2. Danger and warning...3 2.1. Risk of electrocution, burns or explosion...3 2.2.
More informationAC/DC sensitive residual current monitoring module RCMB121-
AC/DC sensitive residual current monitoring module RCMB121- for safe charging of electrical vehicles according to IEC 62752 for IC-CPD and IEC 60364-7-722 for Wall Boxes Vorläufiges Datenblatt RCMB121_D00267_01_D_XXEN/05.2018
More information38 Series - Relay interface modules A. Features /
Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationResidual Current Monitoring Unit RCMU101SN-4P16C
Magtron Residual Current Monitoring Unit(RCMU ) Update: 2017.3.22. V1.0.3 Features Self-check function Single Supply +5 V Positive output for ADC Printed circuit board mounting Characteristics Stable accuracy
More informationSolid State Relay, 1-phase
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relay, 1-phase Short-Circuit Proof, heat sink integrated Main Characteristics: Standards / Approvals: CE C-Ti I Zero-point switching Short-circuit
More informationResidual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range
Technical data System pro M Residual Current-operated Circuit Breakers (RCCBs) System pro M 1 When connecting aluminium conductors ensure that the contact surfaces of the conductors are cleaned, brushed
More informationSwitching Power Supply Type SPP1 60W Enclosed type
Type SPP1 60W Enclosed type Universal AC input full range Short circuit protection Internal input filter High efficiency High average efficiency (meets ErP) Low stand-by power consumption CE, TUV, and
More information