Universal current sensitive RCCBs B type and F type

Size: px
Start display at page:

Download "Universal current sensitive RCCBs B type and F type"

Transcription

1 GE Industrial Solutions Universal current sensitive RCCBs B type and F type Ultimate protection of people and equipment ge.com/ex/industrialsolutions

2 Type B applications Controllers and variable speed drives Battery chargers and inverters Frequency converters Photovoltaic systems, a.c side Charging stations for electric vehicles Installation in general where we can expect d.c. smooth direct residual currents Variable speed machine tools UPS, Computer Data Centers Elevator controls Cranes of all kinds Test set-ups in laboratories Backed-up power supplies Electronic equipment on construction sites

3 Residual Current Circuit Breakers Residual Current Protection Devices Types of Wave form detected by RCCBs and classification RCCBs Type AC Type A-Ai Type F Type B Waveform definition Current waveform Tripping current Sine wave 0,5 to 1 IΔn Pulsating half wave 0,35 to 1,4 IΔn Pulsating 90º/135º wave Pulsating Half wave + diret current (6mA) Pulsating Half wave + diret current (10mA) Current delay angle 90º: 0,25 to 1,4 Iδn Current delay angle 135º: 0,11 to 1,4 IΔn max. 1,4 IΔn+6mA max. 1,4 IΔn+10mA Composite wave 0,5 to 1,4 IΔn General view High frequency (up to 1KHz) Current Frequency 150Hz 0,5 to 2,4 IΔn Current Frequency 400Hz 0,5 to 6 IΔn Current Frequency 1000Hz 1 to 14 IΔn Two phase rectified full wave Three phase rectified full wave Direct current 0,5 to 2 IΔn Discover advantages: Type F Offer the same range of protection and functionality as a Type A RCD; this means that release with sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are capable of detecting residual currents from mixed frequencies of up to 1000 Hz, which can often occur on the outgoing feeder side of singlephase frequency converters. This prevents undesirable interruptions to the electrical supply if, for example, pulsed leakage currents of up to ten milliseconds occur at activation of filter capacitors. Type B In adition to release residual current waveforms of type A, B type RCCBs are used to detect smooth DC residual currents. B Type RCCBs are recommended for use with EV Charge and drives and inverters for supplying motors for pumps, lifts, textile machines, machine tools since they recognise a continuous fault current with low level ripple. Type BS Release residual current waveforms of type B with time delay. Type AC: Release with sinusoidal currents which occur suddenly or slowly rise in magnitude. Type A-Ai: Release with sinusoidal currents and also with pulsating direct current which occur suddenly or slowly rise in magnitude. Type S-Si (type A-Ai): Time delay release with sinusoidal currents and also with pulsating direct current which occur suddenly or slowly rise in magnitude. 3

4 RCCBs RCCBs - Residual Current Circuit Breakers RCCB with overcurrent protection Add-on devices Series FP-FIP Performance EN 62423/ VDE Type B Type BS FP FIP (3) Auxiliaries (1) Motor operator (2) Rated current In (A) FP: 16, 25, 40, 63, 80; FIP: 100, 125 Residual current I (ma) 30, 100, 300, 500 Rated Voltage AC Un (V) 2P: 230 4P: 230/400 Minimum operating voltage U min 30 ma (V) 2P: 160 4P: ,300,500 ma (V) 2P: 117 4P: 205 Mechanical/electrical endurange FP: /10.000; FIP>5000 Tropicalisation acc. to EN/IEC /2-30 and DIN %RH at 55ºC Terminal capacity flexible/rigid cable (mm 2 ) FP: 1,5-50; FIP: 1,5-50 Poles FP: 2, 4; FIP: 4 Nuisance tripping resistance 3000A 8/20 msc Ambient temperature (ºC) -25 up to 40 Weight (g) 2P 340 (g) 4P FP: 420; FIP: 500 Short-circuit capacity (1) Series CA - Tele L - Tele U - PBS - TeleREC Plus (2) Only at right side end of the extreme pin busbar (3) Only FIPH model Wiring Acc. To EN/IEC Making and Breaking capacity Im=500A from 16A up to 40A Im=10In from 63 up to 80A Im=1000A (100A) Im=1250A (125A) Residual making and braking capacity I m=50in from 16A up to 40A I m=10in from 63A up to 80A I m=1000 (100A) I m=1250 (125A) Short-circuit capacity Inc=10000A at 230/400V fuse 80A gg Serie FP - Type B Serie FP - Type B 1 N N 2 N N 4

5 Series FP Type B 30 ma 100 ma 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Pack 16 FPB 2 16/ FPB 2 16/ FPB 2 16/ FPB 2 16/ FPB 2 25/ FPB 2 25/ FPB 2 25/ FPB 2 25/ FPB 2 40/ FPB 2 40/ FPB 2 40/ FPB 2 40/ FPB 2 63/ FPB 2 63/ FPB 2 63/ FPB 2 63/ FPB 2 80/ FPB 2 80/ FPB 2 80/ FPB 2 80/ /3 16 FPB 4 16/ FPB 4 16/ FPB 4 16/ FPB 4 16/ FPB 4 25/ FPB 4 25/ FPB 4 25/ FPB 4 25/ FPB 4 40/ FPB 4 40/ FPB 4 40/ FPB 4 40/ FPB 4 63/ FPB 4 63/ FPB 4 63/ FPB 4 63/ FPB 4 80/ FPB 4 80/ FPB 4 80/ FPB 4 80/ Series FIP Type B 1/3 Series FP-FIP 30 ma 100 ma 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Cat. No. Ref. No. Pack 100 FIPB4100/ FIPB4100/ FIPB4100/ FIPB4100/ FIPB4125/ FIPB4125/ FIPB4125/ FIPB4125/ Series FIP Type BS 300 ma 500 ma In (A) Cat. No. Ref. No. Cat. No. Ref. No. Pack 40 FIPBS440/ FIPBS440/ FIPBS463/ FIPBS463/ FIPBS480/ FIPBS480/ FIPBS4100/ FIPBS4100/ FIPBS4125/ FIPBS4125/ Dimensions Series FP Series FIP 5

6 RCCBs RCCBs - Residual Current Circuit Breakers RCCB with overcurrent protection Add-on devices FP Series FP Performance EN/IEC EN 62423/ VDE Type F Auxiliaries (1) Motor operator (2) (1) Series CA - Tele L - Tele U - PBS - TeleREC Plus (2) Only at right side end of the extreme pin busbar Rated current In (A) 25, 40, 63, 80 Residual current I (ma) 30 Rated Voltage AC Un (V) 2P: 240 4P: 240/415 Minimum operating voltage U min 30 ma (V) 2P: 160 4P: 258 Mechanical/electrical endurange / Tropicalisation acc. to EN/IEC /2-30 and DIN %RH at 55ºC Terminal capacity flexible/rigid cable (mm 2 ) 1,5-50 (1,5-50) Poles 2, 4 (4) Nuisance tripping resistance 3000A 8/20 msc Ambient temperature (ºC) -25 up to 40 Weight (g) 2P 220 (g) 4P 385 Short-circuit capacity Acc. To EN/IEC Making and Breaking capacity Im=500A from 16A up to 40A Im=10In from 63 up to 80A Im=1000A (100A) Im=1250A (125A) Residual making and braking capacity I m=500 from 16A up to 80A I m=10in from 63A up to 80A Short-circuit capacity Inc=10000A at 240/415V (230V/400V) fuse 80A gg Available soon 6

7 Series FP Type F 30 ma In (A) Cat. No. Ref. No. Pack 25 FPF 2 25/ FPF 2 40/ FPF 2 63/ FPF 2 80/ /6 25 FPF 4 25/ FPF 4 40/ FPF 4 63/ FPF 4 80/ /3 Series FP Wiring Serie FP - Type F Serie FP - Type F 1 /2 3 /4 1/2 3/4 5/6 N 2 /1 4 /3 2/1 4/3 6/5 N Dimensions 7

8 RCCBs Auxiliaries for FP RCCB with overcurrent protection Series CA Function Cat. No. Ref. No. Pack 1/2 mod. H CA H S/H CA S/H S/H CA S/H G golden contacts Series CB Function Cat. No. Ref. No. Pack 1/2 mod. SH/HH CB SH/HH-R (1) /40 1/40 (1) Coupling on the right Wiring Serie CA Serie CB H Auxiliaries for FIP 100A and 125 A Contacts Cat. No. Ref. No. Pack 1/2 mod. 1NO+1NC FIPH

9 Add-on Devices for FP Tele MP - Motor operator Voltage Cat. No. Ref. No. Pack 3 mod. AC 230V TELE MP Tele L - Shunt trip Voltage Cat. No. Ref. No. Pack AC 24-60V DC 24-48V TELE L AC V DC V TELE L Auxiliary - Add-on Devices Tele U - Undervoltage release Voltage Cat. No. Ref. No. Pack AC 240V TELE U AC/DC 12V TELE U AC/DC 24V TELE U AC/DC 48V TELE U PBS - Panel board switch Cat. No. Ref. No. Pack 1/2 mod. PBS Wiring Tele MP Tele L Tele U PBS 9

10 RCCBs Technical data RCCB with overcurrent protection Series FP Type B FIP Type B-BS FP Type F Standards EN 62423/ VDE EN 62423/ VDE EN 62423/ VDE Magnetic tripping characteristics Residual tripping characteristic B BS F Tripping time at I Δn Instantaneous ms <300 <300 <300 Selective ms - >130 - Rated current A 16, 25, 40, 63, 80 B: 100,125; BS:40,63,80,100,125 25, 40, 63, 80 Rated residual current I Δn ma 30, 100, 300, 500 B: 30,100,300,500; BS: 300, Calibration temperature ºC Number of poles versus modules 2P = 4 mod.; 4P = 4 mod. 4P = 4 mod. 2P = 2 mod.; 4P = 4 mod. Rated voltage Un 2P AC V P AC - - 4P AC V 230/ / Frequency Hz 50/60 50/60 50/60 Maximum service voltage Ubmax V 2P=265/4P=460 4P=440 2P=265/4P=455 Minimum service voltage Ubmin (30 ma) V 2P=160/4P=258 4P=260 2P=160/4P=258 Minimum service voltage Ubmin (100, 300, 500 ma) V 2P=117/4P=205 4P=260 - Minimum voltage for leakage protection Voltage independent Voltage independent Voltage independent Power supply Top/Bottom Top/Bottom Top/Bottom Energy limiting class Rated making and breaking capacity (Im) A 500 (or 10In) (or 10In) Residual making and breaking capacity (IΔ m) A 500 (or 10In) 100A=1000; 125A= (or 10In) Conditional short-circuit capacity (Inc) A fuse 80A glgg fuse 80A glgg fuse 80A glgg Conditional residual short-circuit capacity (IΔ c) A fuse 80A glgg fuse 80A glgg fuse 80A glgg Rated Short-circuit capacity (Icn) A Grid distance (safety distance between two devices) Isolator application yes yes yes Insulation degree Insulation voltage V(DC) Shock voltage (1.2/50μs) kv 6 6 Insulation resistance Mohm Dielectric strength V Shock resistance (in x, y, z direction) (EN/IEC 60077/16.3) 40g 18 shocks 5ms 20g /20ms 40g 18 shocks 5ms Vibration resistance (in x, y, z direction) (EN/IEC ) 1,5g. 30 min, 0..80Hz 5g, 30 min,0 80Hz 1,5g. 30 min, 0..80Hz Endurance electrical at Un, In > mechanical at Un, In > Protection degree (outside/inside electrical enclosure with door) IP20/IP40 IP20/IP40 IP20/IP40 Self extinguish degree (according to UL94) V2 - V2 Tropicalisation (according to EN/IEC , DIN 40046) ºC/RH 55/95% 55/97% 55/95% Pollution degree (acc. EN/IEC ) Operating temperature -25ºC +40ºC -25ºC +40ºC -25ºC +40ºC Storage temperature -25ºC +70ºC -25ºC +70ºC -25ºC +70ºC Terminals capacity Rigid cable min/max (top) mm 2 1,5/50 (1,5/35) 1,5/50 1,5/50 (1,5/35) Flexible cable min/max (top) mm 2 1,5/35 (1,5/25) 1,5/50 1,5/35 (1,5/25) Rigid cable min/max (bottom) mm 2 1,5/50 (1,5/35) 1,5/50 1,5/50 (1,5/35) Flexible cable min/max (bottom) mm 2 1,5/35 (1,5/25) 1,5/50 1,5/35 (1,5/25) Torque Top/Bottom Nm 5/5 3/mrt 5/5 Add-on devices (side add-on) Auxiliary contacts yes yes yes Tele U yes no yes Tele L yes no yes Tele M yes no yes PBS yes no yes Busbars systems Pin yes yes yes Fork yes yes yes # Poles Dimensions (HxDxW) 86x70xW /72 Weight 2P=340 ; 4P=420 4P=500 2P=220 ; 4P=385 Package 1/3 3 2P=1/6; 4P=1/3 Approvals VDE VDE - CE-marking yes yes yes 10

11

12 GE Industrial Solutions is a first class global supplier of low and medium voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide. Belgium GE Industrial Belgium Nieuwevaart 51 B-9000 Gent Tel. +32 (0) Finland Kuortaneenkatu 2 FI Helsinki Tel (0) France Paris Nord 2 13, rue de la Perdrix F Roissy CDG Cédex Tel. +33 (0) Germany Robert-Bosch Str. 3 D Hürth-Efferen Tel. +49 (0) 2233/ Hungary GE Hungary Kft. Vaci ut H-1139 Budapest Tel Italy Centro Direzionale Colleoni Via Paracelso 16 Palazzo Andromeda B1 I Agrate Brianza (MB) Tel Netherlands Parallelweg 10 Nl-7482 CA Haaksbergen Tel. +31 (0) Poland GE Power Controls Ul. Towarowa 25A, Ip Warszawa Tel Ul. Leszczyńska Bielsko-Biała Tel Russia 27/8, Electrozavodskaya street Moscow, Tel South Africa Unit 4, 130 Gazelle Avenue Corporate Park Midrand 1685 P.O. Box Wendywood 2144 Tel Spain GE POWER CONTROLS IBÉRICA, S.L. Calle Miño 122 Naves E-F Polígono Industrial Santa Margarita Terrassa (Barcelona) Tel United Arab Emirates Injaz Building, 3rd Floor Dubai Internet City PO Box 11549, Dubai Tel United Kingdom 2 The Arena, Downshire Way Bracknell, Berkshire RG12 1PU Tel. +44 (0) ge.com/ex/industrialsolutions Ref. R/2536/E/EX 1.0 Ed. 05/15 * Trademark of General Electric Company Copyright 2015

Modular DIN-rail devices

Modular DIN-rail devices GE Industrial Solutions Modular DI-rail devices Series K ex.geindustrial.com Modulair DI-rail protection.1 Line protection.2 Selection table of Ms.3 Technical data.4 Short-circuit capacity of Ms.7 Series

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

Residual Current Operated Circuit-Breakers (RCCBs)

Residual Current Operated Circuit-Breakers (RCCBs) Product Overview Residual Current Operated Circuit-Breakers (RCCBs) Residual current operated circuit-breakers Number of poles Rated current A Rated residual current ma MW Auxiliary contacts can be mounted

More information

Technical features table for miniature circuit-breakers SH 200 Series

Technical features table for miniature circuit-breakers SH 200 Series Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution

More information

Residual Current Operated Circuit-Breakers (RCCBs)

Residual Current Operated Circuit-Breakers (RCCBs) Product overview Residual Current Operated C ircuit-breakers (RCCBs) Number of poles Rated fault current I n ma Rated current I n A MW Auxiliary switches can be mounted (Type A) (Type B) 5SM1and 5SM3 RCCBs

More information

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION

More information

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Components for Marine applications

Components for Marine applications Components for Marine applications Imagination GE imagination at work. at work v. 10-2015 GE Industrial Solutions Leading the future of electrification GE Industrial Solutions is leading the future of

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

SM2000 TECHNICAL DESCRIPTION

SM2000 TECHNICAL DESCRIPTION SM2000 TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The SM2000 module is a high frequency switch mode rectifier. It converts the single phase AC line voltage into an isolated DC voltage. It can be used

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION

More information

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40 High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40 C O M P O N E N T S The UR26, UR36 & UR40 are DC high-speed current limiting air Circuit-Breakers, trip free, single pole, bi-directional,

More information

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24... P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector

More information

90 ReStart AUTOMATIC RECLOSING DEVICES

90 ReStart AUTOMATIC RECLOSING DEVICES RESTART WITH AUTOTEST Technical data TYPE ReStart with Autotest 2P ReStart with Autotest PRO 2P ReStart with Autotest PRO 4P Electrical characteristics Standards: EN 50557, EN 61008-1 Distribution system:

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.

More information

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented Doepke The experts in residual current protection technology Residual Current Circuit-Breakers it- r with Overcurrent Protection (RCBO) FIB / FIC» effi cient» reliable» fl exible» future-oriented Doepke

More information

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation

More information

Residual current circuit breakers (RCCBs)

Residual current circuit breakers (RCCBs) Residual current circuit breakers (RCCBs) Description Automatically trips in event of earth leakage fault Provides protection against direct & indirect contact with live parts Technical data IS 12640-1,

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

EN 50178, IEC

EN 50178, IEC Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230

More information

technical information

technical information technical information protection devices 192 circuit protection principle 194 circuit breakers characteristics 200 moulded case circuit breakers (MCCB) 205 prospective fault current 208 selectivity and

More information

Phase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement

More information

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and

More information

38 Series - Relay Interface Modules A

38 Series - Relay Interface Modules A Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay

More information

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Low Pass Harmonic Filters

Low Pass Harmonic Filters Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_02_D_XXEN/11.2018

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Circuit protection devices

Circuit protection devices Circuit protection devices MCBs, RCCBs, RCBO, ELR, surge arresters, fuse carriers, complete range of auxiliaries, busbars and connectors EA 2002/1 Welcome to the new edition of our general catalogue For

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_00_D_XXEN/05.2015

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES P. 20-21 DX³ - MCB AC Application upto 63 A MCBs P. 23 DX³ - 25 ka MCB from 6 A to 125 A Isolator RCCB & RCBOs

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

ACS600, ACS800. Installation Guide

ACS600, ACS800. Installation Guide ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60 2003 ABB Oy. All Rights Reserved. 3AFE 58933368

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A High performance circuit breaker mcb and combined mcb with remote controls LV Distribution Products 2-63A Mini motorized circuit breaker The mini-series of motorized circuit breakers operates both locally

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

Electronic circuit breaker ESS30-Sxxx-DC24V

Electronic circuit breaker ESS30-Sxxx-DC24V Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Current Transducer CTSR 0.6-TP/SP2 I PRN = 600 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Features

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

Energy Management Energy Meter Type EM110

Energy Management Energy Meter Type EM110 Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS

COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS Operating instructions EN Contents 1. Documentation...3 2. Danger and warning...3 2.1. Risk of electrocution, burns or explosion...3 2.2.

More information

AC/DC sensitive residual current monitoring module RCMB121-

AC/DC sensitive residual current monitoring module RCMB121- AC/DC sensitive residual current monitoring module RCMB121- for safe charging of electrical vehicles according to IEC 62752 for IC-CPD and IEC 60364-7-722 for Wall Boxes Vorläufiges Datenblatt RCMB121_D00267_01_D_XXEN/05.2018

More information

38 Series - Relay interface modules A. Features /

38 Series - Relay interface modules A. Features / Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Residual Current Monitoring Unit RCMU101SN-4P16C

Residual Current Monitoring Unit RCMU101SN-4P16C Magtron Residual Current Monitoring Unit(RCMU ) Update: 2017.3.22. V1.0.3 Features Self-check function Single Supply +5 V Positive output for ADC Printed circuit board mounting Characteristics Stable accuracy

More information

Solid State Relay, 1-phase

Solid State Relay, 1-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relay, 1-phase Short-Circuit Proof, heat sink integrated Main Characteristics: Standards / Approvals: CE C-Ti I Zero-point switching Short-circuit

More information

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range Technical data System pro M Residual Current-operated Circuit Breakers (RCCBs) System pro M 1 When connecting aluminium conductors ensure that the contact surfaces of the conductors are cleaned, brushed

More information

Switching Power Supply Type SPP1 60W Enclosed type

Switching Power Supply Type SPP1 60W Enclosed type Type SPP1 60W Enclosed type Universal AC input full range Short circuit protection Internal input filter High efficiency High average efficiency (meets ErP) Low stand-by power consumption CE, TUV, and

More information