1 MODEL SWS-232 MODEL SWS-485 SONIC WEATHER SENSOR OPERATION MANUAL Document No. SWS-9800 Rev. A Met One Instruments 1600 Washington Blvd. Regional Sales & Service Grants Pass, Oregon Main St. Suite 106 Telephone Rowlett, Texas Facsimile Telephone Facsimile SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 1 of 19

2 Copyright Notice SWS Sonic Weather Sensor Manual Copyright 2013 Met One Instruments, Inc. All Rights Reserved Worldwide. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language in any form by any means without the express written permission of Met One Instruments, Inc. Technical Support Should you require support, please consult your printed documentation to resolve your problem. If you are still experiencing difficulty, you may contact a Technical Service representative during normal business hours 7:30 a.m. to 4:00 p.m. Pacific Standard Time, Monday through Friday. Voice: (541) Fax: (541) service@metone.com Mail: Technical Services Department Met One Instruments, Inc Washington Boulevard Grants Pass, OR SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 2 of 19

3 Safety Notice The contents of this manual have been checked against the hardware and software described herein. Since deviations cannot be prevented entirely, we cannot guarantee full agreement. However, the data in this manual is reviewed regularly and any necessary corrections are included in subsequent editions. Faultless and safe operation of the product presupposes proper transportation, storage, and installation as well as careful operation and maintenance. The seller of this equipment cannot foresee all possible modes of operation in which the user may attempt to utilize this instrumentation. The user assumes all liability associated with the use of this instrumentation. The seller further disclaims any responsibility for consequential damages. Electrical & Safety Conformity The manufacturer certifies that this product operates in compliance with the following standards and regulations: FDA/CDRH This product is tested and complies with 21 CFR, Subchapter J, of the Health and Safety Act of 1968 US 21 CFR Warranty All instruments are warranted against defects in parts or workmanship for a period of one (1) year from the date of shipment. Should any instrument or part prove to be defective within the warranty period, upon written notice and return of the unit (freight prepaid), Met One Instruments, Inc. will, at its option, repair or replace the defective unit, and return it, transportation prepaid via UPS. Equipment abused, modified, or altered may cause cancellation of this warranty. The above warranty applies only to items manufactured by Met One Instruments, Inc. Items not manufactured by Met One Instruments, Inc. are warranted only to the extent and in the manner warranted by the manufacturer of such items. Should emergency warranty repair be required at a customer's facility, Met One Instruments, Inc. will provide such repairs and charge only the portal-to-portal Field Service rates and actual expenses in accordance with our published rates then in effect. Expendable supplies and wear items, such as bearings and lightning related damages, are not covered under this warranty. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 3 of 19

4 Table of Contents 1. Introduction & Overview Sonic Weather Sensor (SWS) Overview Specifications Unpacking & Installation Unpacking Deployment Operational Checkout Maintenance Input/Output Connections Setting Magnetic Declination User Selectable Options User Interface Output Format Detail Standard Configuration Serial Interface Wind Speed Range Temperature Range Pressure Range Averaging Interval BV and CV Defaults... Error! Bookmark not defined. 8. Appendix A Terminal Mode and SDI Commands Appendix B Theory of Operation SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 4 of 19

5 1. Introduction & Overview Sonic Weather Sensor (SWS) 1.1. Overview The Sonic Weather Sensor (models SWS-232 and SWS-485), is a weather instrument that provides measurements of wind speed, wind direction, ambient air temperature, relative humidity, and barometric pressure in a single, compact, rugged unit. The SWS integrates a folded-path, low-power sonic anemometer with a precision thermistor temperature sensor, fast-response capacitive relative humidity sensor, state-of-the-art barometric pressure sensor and an optional internal flux-gate compass for automatic alignment of wind direction to magnetic north. The small footprint and power efficiency of the SWS make it ideal for remote regions, urban environments, air quality networks, construction/remediation sites, and other network applications. The unit can be used in permanent (cooperative weather networks, schools, public information dissemination) or temporary (emergency response, audit, research program support) installations. Designed for maximum portability and utility, the SWS is well suited for rapid deployment and use by one person under all conditions. The unit may be mounted on a tower, tripod or vehicle mast. Data output is a serial, digital message that can be interfaced to most data logging systems. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 5 of 25

6 2. Specifications PERFORMANCE Wind Speed Range 0 to 60 m/s (0 to 134 mph) Accuracy ±0.5 m/s or 5% of reading (1) Resolution 0.1 m/s Wind Direction Range 0 to 360 Accuracy ± wind speed > 2.2 m/s Resolution 1.0 Temperature Range -40 to +60 C (-40 to +140 F) Accuracy ±0.2 C (2) Resolution 0.1 C Relative Humidity Range 0 to 100% Accuracy ±3% (3) Resolution 1.0% Pressure Range 600 to 1100 hpa Accuracy ±0.5 hpa (3) Resolution 0.1 hpa Compass Option Accuracy ±2 Resolution 1 ELECTRICAL Measurement Rate Output: 1 Hz Signal Output RS-232, RS-485, and SDI-12 Power Requirements 8 to ma nominal, option dependent ENVIRONMENTAL Temperature -40 C to +60 C (-40 to +140 F) Humidity 0 to 100% Notes: 1. Whichever is greater. 2. 0C to 60C. +/- 0.5C from -40C to 0C. 3. At 25 C. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 6 of 19

7 3. Unpacking & Installation 3.1. Unpacking When you unpack the SWS and accessories, first inspect the carton for any obvious damage. If the carton is damaged notify the carrier immediately. Please note it may be useful to take a couple of photos for future reference. Unpack the SWS and accessories and make a visual inspection of the items. The SWS Sonic Weather Sensor is shipped with the following items: 5-in-1 Sonic Weather Sensor, p/n SWS-232 or SWS-485. Pipe top mounting adaptor, p/n Calibration certificate. Operation manual (this document). If purchased, the following options may also be included: signal cable. Automatic alignment compass (pre-installed inside SWS). If any of the above components are missing contact Met One Instruments Customer Service Department at service@met One Instruments.com or Please keep the carton(s) and associated packing materials for reuse. Be sure to mount the sensor in a clear, open area to minimize any turbulent effects caused by local obstructions (e.g., trees, buildings, etc.). SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 7 of 19

8 3.2. Deployment Install the mounting adaptor onto the top of any 1 IPS pipe (1.34 OD). If not using the internal alignment compass, align the mounting adaptor so that the long slot in the side faces south. Run the signal cable up through the mount adaptor and plug it into the base of the SWS. Turn the connector sleeve clockwise (seen from below) until tight. Insert the SWS onto the mount adaptor and ensure the South alignment set screw slides down into the corresponding slot on the upper edge of the mount adaptor. Once the sensor is firmly seated and aligned on the mounting adaptor, tighten the 2 slotted base set screws. Run the signal cable from the mount to the data collection device being used (data logger or computer) following the wiring connections in Section Operational Checkout Connect SWS to your data logger or recording electronics. Connect power to the sensor cable per wiring diagram in section 3.5. Your recording electronics should start displaying or recording measurements from the SWS. Using experience or data from a local weather source compare the values for reasonableness. If the data looks OK, the unit is in operation. If data is questionable, contact Met One Instruments, Inc. Service Department for further guidance at (541) Maintenance The unit has no moving parts and therefore requires no periodic maintenance for wear items. It is recommended that the data be checked every 6-12 months to be sure there has been no failure of any of the electrical components. This can be done using a small container over the sensor to zero check the wind measurement, and any co-located temperature, relative humidity device such as Met One Instruments, Inc. 083E-1-35 and co-located pressure sensor such as Met One Instruments P/N 092. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 8 of 19

9 3.5. Input / Output Connections The sensors wiring designations are as follows: RED BLK WHT BRN GRN BLU ORN WHT/BRN POWER POSITIVE POWER COMMON RS-232 TX (SWS-232) OR RS-485+ (SWS-485) RS-232 RX (SWS-232) OR RS-485- (SWS-485) SIGNAL COMMON SDI-12 EXTERNAL RAIN GAUGE INPUT SHIELD (must be grounded for transient protection to function) Warning: Do not short any of the signal or power wires to ground or to each other Setting Magnetic Declination If the optional internal flux gate compass is ordered, the wind direction in the SWS is automatically corrected to magnetic North and the unit will require no orientation upon deployment. Therefore it is important to understand and know the magnetic declination of the area in which the sensor will be operated. The declination in the SWS is factory set at zero degrees. To change this, refer to the MD command on page 15 for setting the Magnetic Declination. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 9 of 19

10 4. User Selectable Options The following User Defined Options can be set following the instructions detailed in Appendix A. MD Set Magnetic Declination OI Set Output Interval PU Set Pressure Units QU Quit command mode and save any changes SA SDI Address ST Set Serial Trigger Address SU Set Speed Units TU Set Temperature Units SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 10 of 25

11 5. User Interface The output of the SWS is a fixed length, comma delimited, serial data stream. The serial output is factory set for 9600 baud, no parity, 8 data bits, with 1 stop bit (N, 8, 1). The output interval default is once per second. This may be changed using the OI command (see Appendix A). The data is easily viewed and can be displayed and captured using Met One Instruments Comet Software or other terminal communication program. An example of the standard output format is shown below: 000.6,272,+023.6,022,0974.3,00.0,00.0,12.7,U0,*2257 Each parameter is a fixed length with leading zeros separated by a comma. The string terminates with a Carriage Return and Line Feed. Field parameters are defined as: 000.6,272,+023.6,022,0974.3,00.0,00.0,12.7,U0,*2257 WS,WD,Temp,RH,BP,NF1,NF2,CONFIG,CheckSum m/sec,deg,deg C,%,mbars The measurement units noted in the sample output data string are the default output units. The wind speed, temperature, and pressure units can be changed with the SU, TU, and PU terminal commands respectively. Please refer to Appendix A for more information. Polled data mode (RS232 or RS485) The sensor can be set for polled data mode instead of continuous serial output by setting the serial trigger string while in terminal mode. Refer to the ST terminal command in Appendix A. Additional help for setting this option is available in the sensor s ST menu. Type ST for help with this command. SDI-12 Interface In addition to the above communications methods, the sensor can be polled by an SDI-12 Master Station for data. This operates completely independent of the RS232 or RS485 communications and can be used in conjunction with those methods. Data are polled using a series of SDI-12 commands. Please see appendix A for a list of supported SDI commands. The default SDI Address for the BTOF is zero. The output format has the same basic structure as the RS232 output format, WS WD TMP RH BP BATT COMPASS. Please consult your data-logger manual for more information on SDI interfaces or call Met One for additional help. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 11 of 25

12 6. Output Format Detail The BTOF will only support one output format. This format will use fixed length fields but also include commas to accommodate either CSV import of the data or legacy programs which expect fixed length fields. The parameter order is shown in the table below. Field Parameter 01 Wind Speed 02 Wind Direction 03 Ambient Temperature 04 Relative Humidity 05 Barometric Pressure 06 Option field 07 Option field 08 Battery Voltage 09 Config. & Status 10 Check Sum The SWS will report data at a rate set using the OI user command, and is typically set to one second. An example is shown below ,272,+023.6,022,0974.3,00.0,00.0,12.7,U0,*2257 Note: when displaying the pressure in In/Hg, there will be an extra leading zero character but the fixed length of the field will not change. A check sum parameter will be added to the end of the message (*9999). The check sum is the addition of all the characters from the start of the message through the first character preceding the asterisk (*). The check sum is expressed as a decimal number. This is a 16 bit sum and should not overflow past 4 digits given the number of characters in the output string. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 12 of 25

13 7. Standard Configuration Serial Interface The serial interface will be fixed at 9600 Baud and configured for No Parity, 8 Data Bits and 1 Stop Bit. Wind Speed Range The Wind Speed Range choices will be limited to Mph or M/S. The Speed range for M/S is The Speed range for MPH is The Default will be M/S. Temperature Range The Temperature Ranges choices will be either Degrees C or Degrees F. The default is Degrees C. The range for Degrees C is -40 to +60, the range for Degrees F is -40 to Pressure Range Pressure Range choices will remain In/Hg or Millibars. Default is Millibars. The Pressure range for Millibars is The Pressure Range for In/Hg is to Averaging Interval The Averaging Interval will be fixed to a rolling 5 second average. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 13 of 19

14 8. Appendix A 8.1. Terminal Mode and SDI Commands RS232 / RS485 Terminal Mode Commands Terminal mode is activated by entering three carriage return characters within a 2 second period. Terminal mode times-out after 2 minutes of inactivity. Successful entry into Terminal Mode will return an asterisk prompt: H,h,? - Display Help Menu H,h,? - This Help Menu ID View / Set Instrument ID MD - Set Magnetic Declination OI - Set Output Interval PU - Set Pressure Units SA - SDI Address ST - Set Serial Trigger Address SU - Set Speed Units TU - Set Temperature Units RV - Display Firmware Version Number Q - Quit command mode and save any changes NOTE: The commands noted in this appendix will change both the RS232 and RS485 outputs. The SDI-12 output can be configured independently. See pages below for SDI-12 commands. SU - Wind Speed Units Read or Set this serial port s output Units for Wind Speed COMMAN RESULT D SU<cr> SU0<cr> SU1<cr> Report Units setting M/S MPH SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 14 of 19

15 TU - Temperature Units Read or Set this serial port s output Units for Temperature COMMAN RESULT D TU<cr> TU0<cr> TU1<cr> Report Units setting Fahrenheit Celsius PU - Pressure Units Read or Set this serial port s output Units for Pressure COMMAN RESULT D PU<cr> PU0<cr> PU1<cr> Report Units setting Millibars (Default) Inches of Mercury MD - Magnetic Declination The optional flux compass in the SAMMIE sensor provides Wind Direction to MAGNETIC north. Software in the Interface allows the setting of a declination angle to correct the Wind Direction output to TRUE north. It is recommended that this procedure be done in the lab, but can be done in the field as well. Once the declination angle is set in the sensor, it is stored in non-volatile memory, and does not have to be reset each time the sensor is fielded. The declination angle must be reset only if the system is used in a different geographical location separated by many miles from the location where the declination was originally set. It is suggested that the magnetic declination be determined before performing this calibration. Visit the following web site for help in determining the correct declination for your site: Enter your zip code and click "Get Location". On the next page, click "Compute!" At the bottom of the page, Field "D" is declination in degrees and minutes. Divide minute s value by 60 to get decimal remainder of degrees (I.E. 50 minutes = 0.8 degrees). If the declination needs to be adjusted, please use the MD command as shown below. Read or Set the Magnetic Declination COMMAND RESULT MD<cr> MDXX.X<cr > Report Magnetic Declination setting Set Declination to XX.X Degrees Note: West declination values are entered and reported as negative values. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 15 of 19

16 OI - Output Interval Read or Set the Output Interval for this serial port Note: This command is not supported by SDI-12, CAMEO/ALOHA, or Tracker Output. COMMAN RESULT D OI<cr> OI<cr> OI2<cr> OI3<cr> OI4<cr> OI5<cr> OI6<cr> Report Output Interval setting Sensor Output every 1 second (Default) Sensor Output every 2 seconds Sensor Output every 5 seconds Sensor Output every 15 seconds Sensor Output every 30 seconds Sensor Output every 60 seconds ST - Serial Trigger Read or Set the Serial Trigger character string (Poll command) COMMAND RESULT ST<cr> ST XXXXXX<cr> Report Serial Trigger string setting (provides help) Set Serial Trigger RV - Software Version Number Report the current Software Version Number COMMAN RESULT D RV<cr> Report current Software Version SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 16 of 19

17 SDI-12 Commands NAME SDI-12 COMMAND SENSOR RESPONSE Address Query?! a<cr><lf> Where a = address Acknowledge Active a! a<cr><lf> Where a = address Send Identification ai! a13metone SWS 0.2 0Axxxxx<CR><LF> Where a=address and xxxxx = S/N Change Address aab! b<cr><lf> Where b = new address Start Measurement amc! a0008<cr><lf> Where a = address Send Data ad0! a+bbb.b+ccc.c+ddd.d+eee.e<cr><lf> Where a = address, bbb.b = wind speed, ccc.c = wind direction, ddd.d = temperature, and Send Data eee.e = relative humidity Start Concurrent Measurement Start Concurrent Measurement with CRC ad1! ac! acc! a+ffff.f+ggg.g+hhh+ii.ii<cr><lf> Where a = address, ffff.f = barometric pressure, gg.gg = Extra1, hh.hh = Extra 2, and ii.ii = Power Supply Voltage a00008<cr><lf> Where a = address a00008<cr><lf> Where a = address Continuous Measurements ar0! a+bbb.b+ccc.c+ddd.d+eee.e<cr><lf> Where a = address, bbb.b = wind speed, ccc.c = wind direction, ddd.d = temperature, and eee.e = relative humidity Continuous Measurements eee.e = relative humidity, and {crc} = CRC with CRC ar1! arc0! a+ffff.f+ggg.g+hhh+ii.ii<cr><lf> Where a = address, ffff.f = barometric pressure, gg.gg = Extra1, hh.hh = Extra 2, and ii.ii = Power Supply Voltage a+bbb.b+ccc.c+ddd.d+eee.e{crc}<cr><lf> Where a = address, bbb.b = wind speed, ccc.c = wind direction, ddd.d = temperature, eee.e = relative humidity, and {crc} = CRC SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 17 of 19

18 NAME SDI-12 COMMAND arc1! SENSOR RESPONSE a+ffff.f+ggg.g+hhh+ii.ii<cr><lf> Where a = address, ffff.f = barometric pressure, gg.gg = Extra1, hh.hh = Extra 2, and ii.ii = Power Supply Voltage Report Wind Units Set Wind Units axsub axsu! axsub! axsub!<cr><lf> Where a = address, and b = 0 for Meters per Second (default), or 1 for Miles per Hour Report Temperature Units Set Temperature Units axtu! axtud! axtud<cr><lf> Where a = address, and d = 0 for Celsius (default), or 1 for Fahrenheit Report Pressure Units Set Pressure Units axpu! axpuf! axpuf<cr><lf> Where a = address, and f = 0 for Millibars (default), or 1 for Inches of Mercury Report Version Number axrv! axvnxx.x<cr><lf> Where a = address and xx.x = firmware version SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 18 of 19

19 9. Appendix B Wind 9.1. Theory of Operation The Met One sonic anemometer operates on the principal that the speed of the wind affects the time it takes for sound to travel from one point to a second point. If the sound is traveling in the direction of the wind then the transit time is decreased. If the sound is traveling in a direction opposite the wind then the transit time is increased. Temperature/Humidity The temperature sensor in the SWS uses a precision Thermistor. This provides highly accurate and stable temperature readings. This allows the SWS to directly interface with the temperature sensor without additional electronics. Sensor compensation is handled through software. The relative humidity sensor is a capacitive polymer sensor which is constructed to provide excellent resistance to wetting, dust, dirt, oils, and common environmental chemicals. A heavy contaminant layer of dirt will slow down the sensor s response time because it will take longer for water vapor to equilibrate in the sensor. Pressure sensor The barometric pressure sensor is a stable transducer using nano-technology, yielding a linear and repeatable sensor with low hysteresis. This piezo-resistive pressure sensor module is mounted on an electronic circuit board within the sensor. A microcontroller controls the operation of the sensor and the data interface. The microcontroller polls the pressure sensor module once per second for the barometric pressure and the ambient temperature. The raw readings are temperature corrected by the microcontroller. Fluxgate Compass The optional internal compass module is low power and compact. It employs a pair of magneto-resistive sensors, which change with varying magnetic field strengths, to sense the Earth s magnetic field. The SWS microprocessor measures the output of the internal compass and then corrects the wind direction data for the orientation of the sensor. The output of the SWS wind direction is relative to magnetic North. A user programmable value of Magnetic Declination may optionally be entered through terminal mode. This enables wind direction output relative to True rather than Magnetic North. SWS-9800 Rev A SWS Sonic Weather Sensor Operation Manual 19 of 19

S2 SONIC ANEMOMETER OPERATION MANUAL

S2 SONIC ANEMOMETER OPERATION MANUAL S2 SONIC ANEMOMETER OPERATION MANUAL Main Office: 140 Wilbur Place Bohemia, NY 11716 631-567-7300 (P) 631-567-7585 (F) www.climatronics.com West Coast Service: 1600 NW Washington Blvd. Grants Pass, OR

More information

SENSORS CLIMATRONICS CORPORATION (631) MANUAL HEATED SONIC ANEMOMETER, S2 P/N M Rev INSTALLATION 1.

SENSORS CLIMATRONICS CORPORATION (631) MANUAL HEATED SONIC ANEMOMETER, S2 P/N M Rev INSTALLATION 1. SENSORS MANUAL HEATED SONIC ANEMOMETER, S2 P/N M102729 Rev - 1.0 INTRODUCTION Climatronics heated sonic anemometer is designed as a stand-alone sensor to provide accurate measurements of wind speed and

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86000-SDI R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ELECTRONIC COMPASS W/ SERIAL INTERFACE MODEL 32500 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772

More information

SENSORS CLIMATRONICS CORPORATION (631) MANUAL HEATED SONIC ANEMOMETER P/N M Rev A 2.0 INSTALLATION 1.

SENSORS CLIMATRONICS CORPORATION (631) MANUAL HEATED SONIC ANEMOMETER P/N M Rev A 2.0 INSTALLATION 1. SENSORS MANUAL HEATED SONIC ANEMOMETER P/N M102622 Rev A 1.0 INTRODUCTION Climatronics heated sonic anemometer is designed as a stand-alone sensor to provide accurate measurements of wind speed and wind

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ELECTRONIC COMPASS W/ SERIAL INTERFACE MODEL 32500 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86106 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS SERIAL INTERFACE MODEL 32400 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86004 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 Barometric Pressure: WE100 Solar Radiation: WE300

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86004 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ResponseONE MODEL 92000 WEATHER TRANSMITTER R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB:

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Barometric Pressure: WE100 Solar Radiation: WE300 Wind Speed: WE550 Wind

More information

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual WS-7212NU Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup Guide 5-9 Function Keys 5 Detailed Set-up Guide 10-15

More information

OPERATIONS & MAINTENANCE MANUAL

OPERATIONS & MAINTENANCE MANUAL Accubar SDI-12 Barometric Pressure Sensor 5600-0120-3 OPERATIONS & MAINTENANCE MANUAL Part No. 8800-1191 Revision B 30 Nov 2017 Accubar SDI-12 Barometric Pressure Sensor Operations & Maintenance Manual

More information

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009 User s Guide Publication number 34134-90001 April 2009 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. Copyright Agilent

More information

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide GM8036 Laser Sweep Optical Spectrum Analyzer Programming Guide Notices This document contains UC INSTRUMENTS CORP. proprietary information that is protected by copyright. All rights are reserved. This

More information

HydroLynx Systems, Inc.

HydroLynx Systems, Inc. Model 50386R-RP Receiver and Repeater Instruction Manual Document No: A102684 Document Revision Date: August, 2006 Receiving and Unpacking Carefully unpack all components and compare to the packing list.

More information

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 85000 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

RJE INTERNATIONAL, INC. VADR VEHICLE ACOUSTIC DIRECTIONAL RECEIVER USER MANUAL REV 1.4

RJE INTERNATIONAL, INC. VADR VEHICLE ACOUSTIC DIRECTIONAL RECEIVER USER MANUAL REV 1.4 RJE INTERNATIONAL, INC. VADR VEHICLE ACOUSTIC DIRECTIONAL RECEIVER USER MANUAL REV 1.4 Forward This manual is comprised of figures and text intended to provide descriptions and instructions for the deployment,

More information

AWOS Net User s Manual

AWOS Net User s Manual Automated Weather Observing System AWOS Net User s Manual 3211-001 Rev. A All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com Copyright 2011 2018, All Weather,

More information

Technical Specification Temperature-Humidity-Pressure Sensor

Technical Specification Temperature-Humidity-Pressure Sensor Technical Specification ITEM CODE RELEASE DATE AUTHOR B80951-01 24 th October 2017 T. Thiesing REVISION REVISION DATE VERSION AUTHOR B-COMMAND GmbH Gruetzmuehlenweg 46 22339 Hamburg Germany FON: +49 40

More information

Interfacing To Climatronics Tacmet II Sonic Weather Station

Interfacing To Climatronics Tacmet II Sonic Weather Station H NS AN_CLI Interfacing To Climatronics Tacmet II Sonic Weather Station 1/10/01 1.0 General The CPP-3794 provides an interface with the Climatronics Tacmet II Sonic Weather Station. The basic unit provides

More information

Wireless Pressure Station

Wireless Pressure Station Wireless Pressure Station FORECAST RELATIVE PRESSURE PRESSURE HISTORY inhg -24h -18h -12h -9h- 6h -3h0 h INDOOR For online video support: http://bit.ly/laxtechtalk Model: 308-1417 DC: 111517 Table of Contents

More information

OP735. Benchtop Optical Power Meter Instruction Manual

OP735. Benchtop Optical Power Meter Instruction Manual Benchtop Optical Power Meter Instruction Manual www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 (7:30 a.m. to 5 p.m. PST) www.optotest.com engineering@optotest.com OptoTest

More information

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL ENGINEERED AUTOMATED SYSTEMS DESIGNERS ENGINEERS MANUFACTURERS SALES REPRESENTATIVES 4580 W. HWY 80 P.O. BOX 4096 MIDLAND, TEXAS

More information

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806 Series 500 Analog Transmitters by Data Industrial Data Industrial Owner s Manual Data Industrial 2/95 PN 72806 Table of Contents Introduction... 1 4-20 ma Loop Supply Requirements... 2 Installation...

More information

Signature Choral Riser Side Rail

Signature Choral Riser Side Rail Assembly/Owner s Manual Signature Choral Riser Side Rail Signature Choral 3-Step Riser with Optional Side Rail Signature Choral 4-Step Riser with Optional Side Rail CONTENTS Visit the Signature Choral

More information

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

OnBoard Bass Drum/Gong Cart

OnBoard Bass Drum/Gong Cart Assembly and Owner s Manual OnBoard Bass Drum/Gong Cart CONTENTS Important User Information...................................................................2 Safety...................................................................................3

More information

OPERATIONS & MAINTENANCE MANUAL

OPERATIONS & MAINTENANCE MANUAL Accubar Multi-Interface Barometric Pressure Sensor Models 5600-0120-1 & -2 OPERATIONS & MAINTENANCE MANUAL Part No. 8800-1136 Rev. F March 2011 Sutron Corporation 22400 Davis Drive Sterling, VA 20164 703.406.2800

More information

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual IRU-2xx4/3xx4 Series Rev. A2, 11/08 Doc. 9002673 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com IRU-2xx4/3xx4

More information

Weather Transmitter WXT510 USER'S GUIDE

Weather Transmitter WXT510 USER'S GUIDE Weather Transmitter WXT510 USER'S GUIDE M210470EN-B October 2004 PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages

More information

MX200 Sensor Controller Manual

MX200 Sensor Controller Manual MX200 Sensor Controller Manual 25 April 2018 Rev K The information in this document is protected under applicable federal law as an unpublished work and is confidential and proprietary to Co2Meter Inc.

More information

Atomic Forecast Station with Moon Phase

Atomic Forecast Station with Moon Phase Atomic Forecast Station with Moon Phase For online video support: http://bit.ly/laxtechtalk Model: S84107 Instruction Manual DC: 080817 Welcome to the La Crosse Technology family! We hope you enjoy your

More information

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741

More information

MODEL ULTRASONIC ANEMOMETER

MODEL ULTRASONIC ANEMOMETER MODEL 81000 ULTRASONIC ANEMOMETER May 2002 1. MODEL 81000 ULTRASONIC ANEMOMETER 2.0 INTRODUCTION The Young Model 81000 measures three dimensional wind velocity based on the transit time of ultrasonic acoustic

More information

Wireless Pressure Station with Backlight

Wireless Pressure Station with Backlight Wireless Pressure Station with Backlight FORECAST RELATIVE PRESSURE PRESSURE HISTORY inhg -24h -18h -12h -9h- 6h -3h0 h INDOOR For online video support: http://bit.ly/laxtechtalk Model: 308-1417BL DC:

More information

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure QS300480 Rev B 2013 Flowline, Inc. All Rights Reserved Made in USA 10500 Humbolt Street, Los Alamitos, CA

More information

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the

More information

PORTROD WALL MOUNTED HEIGHT ROD

PORTROD WALL MOUNTED HEIGHT ROD PORTROD WALL MOUNTED HEIGHT ROD USER INSTRUCTIONS P/N UMPORTROD Rev 1-052112 1 PORTROD Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully, and keep

More information

Cyclops Integrator User s Manual

Cyclops Integrator User s Manual Cyclops Integrator User s Manual August 7, 2015 P/N 998-2602 Revision B TURNER DESIGNS 1995 N. 1 st Street San Jose, CA 95112 Phone: (408) 749-0994 FAX: (408) 749-0998 Table of Contents 1. Introduction

More information

Wind Transmitter - with frequency output xx.xxx

Wind Transmitter - with frequency output xx.xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021531/11/09 Wind Transmitter - with frequency output 4.3303.xx.xxx ADOLF THIES GmbH & Co. KG Hauptstraße

More information

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit

More information

Please read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart.

Please read and understand the OnBoard Timpani Cart Owner s Manual before using the Timpani Cart. Assembly and Owner s Manual OnBoard Timpani Cart Performance Position Towing Position CONTENTS Important User Information...........................2 General......................................2 Manufacturer.................................2

More information

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Table Of Contents Overview of the operating buttons... 4 The functions of the datalogger... 5 How to start logging from the default settings...

Table Of Contents Overview of the operating buttons... 4 The functions of the datalogger... 5 How to start logging from the default settings... Table Of Contents 1. Overview of the operating buttons... 4 2. The functions of the datalogger... 5 2.1 LOG... 5 2.2 METER... 5 2.3 REVIEW... 5 2.4 TIME / date... 5 2.5 START time / date... 5 2.6 INT log

More information

USER'S MANUAL. Model : K

USER'S MANUAL. Model : K USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include

More information

CS105 BAROMETRIC PRESSURE SENSOR

CS105 BAROMETRIC PRESSURE SENSOR REVISION: 3/97 COPYRIGHT (c) 1995-1997 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The CS105 BAROMETRIC PRESSURE SENSOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials

More information

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/06/09 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx 4.3129.80.xxx

More information

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1 Instruction Manual ABM HART Gateway Software Instruction Manual Revision A.1 Table of Contents Section 1: Getting Started... 3 1.1 Setup Procedure... 3 1.2 Quick Setup Guide for Ultrasonic Sensors... 11

More information

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 457B Seven Port Active Twinax Star Hub An ISO-9001 Certified Company Part #07M457B-C Doc. #069011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

More information

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE OPERATING THIS EQUIPMENT! 116 Willow Road Starkville, MS 39759 USA 662-323-8211 Version 3B Printed in U.S.A.

More information

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd AES/EBU Digital Audio Distribution Amplifier User Manual Revision 02 AES/EBU DIGITAL AUDIO DISTRIBUTION AMPLIFIER Revision History: Revision Date By Change Description Applicable to: 00 15/03/2005 AL Original

More information

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS

More information

SSI-4 PLUS User Manual

SSI-4 PLUS User Manual SSI-4 PLUS User Manual 1 SSI-4 PLUS... 2 1.1 Getting to Know the SSI-4 PLUS... 2 1.2 Channel Functions... 3 2 Wiring and Setup... 3 2.1 Powering the SSI-4 PLUS... 3 2.2 5V for External Sensors... 4 2.3

More information

Assembly Instructions Signature Choral Riser 4-Step Model

Assembly Instructions Signature Choral Riser 4-Step Model Assembly Instructions Signature Choral Riser 4-Step Model Contents Important User Information...........................2 General...2 Manufacturer...2 Intended Use...2 Warranty...2 Safety Precautions.................................3

More information

PRX4SERL Four Zone Receiver Decoder

PRX4SERL Four Zone Receiver Decoder PRX4SERL Four Zone Receiver Decoder Operating Manual Microframe Corporation 604 S. 12 th Street Broken Arrow, OK 74012 Tel: (918) 258-4839 Toll Free: 1-800-635-3811 Website: www.microframecorp.com E-mail:

More information

ProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009

ProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009 ProLink Radio 900 MHz SDI-12 Data Radio Scienterra Limited Version A-0x0C-1-AC 20 October 2009 For sales inquiries please contact: ENVCO Environmental Collective 31 Sandringham Rd Kingsland, Auckland 1024

More information

Product Specification for model TT Transducer Tester Rev. B

Product Specification for model TT Transducer Tester Rev. B TT Rev B April 20, 2010 Product Specification for model TT Transducer Tester Rev. B The Rapid Controls model TT Rev B transducer tester connects to multiple types of transducers and displays position and

More information

SCREENING EFFICIENCY TESTER Model 271

SCREENING EFFICIENCY TESTER Model 271 SCREENING EFFICIENCY TESTER Model 271 Operating Manual 11/1/05 1 1.0 INTRODUCTION Conductive suits are worn by power company personnel for protection while performing maintenance on live wire transmission

More information

VMA205 WIFI ESP8266 SHIELD

VMA205 WIFI ESP8266 SHIELD WIFI ESP8266 SHIELD USER MANUAL USER MANUAL 1. Introduction To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates

More information

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections

More information

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B.   Innovation through Guidance. Autonomous Vehicles Device Description HG G-84300-B Autonomous Vehicles Gyroscope HG G-84300-B Gyro for AGV English, Revision 06 Date: 24.05.2017 Dev. by: MG/WM/Bo Author(s): RAD Innovation through Guidance www.goetting-agv.com

More information

Guard Rail with In-Fill Panel

Guard Rail with In-Fill Panel Assembly Instructions Guard Rail for Wenger Versalite TM TM, Trouper, Stagehand, Portamaster, Showmaker Platform Systems Guard Rail with In-Fill Panel CONTENTS Important User Information...........................................................................

More information

Wireless Color Weather Station

Wireless Color Weather Station Wireless Color Weather Station INSTRUCTION MANUAL MODEL: C85845V3 DC: 120518 FIND MANUALS, FAQS, AND MORE UNDER THE SUPPORT TAB HERE: bit.ly/c85845v3 TABLE OF CONTENTS 3. Power Up 3. LCD Features 4. Buttons

More information

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc. User s Guide RP7000 Series Active Probe Dec. 2012 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2011 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered

More information

NOVALYNX CORPORATION MODEL 110-WS-16TH TEMPERATURE AND RELATIVE HUMIDITY SENSOR INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 110-WS-16TH TEMPERATURE AND RELATIVE HUMIDITY SENSOR INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 110-WS-16TH TEMPERATURE AND RELATIVE HUMIDITY SENSOR INSTRUCTION MANUAL REVISION DATE: NOV 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing

More information

High power radio transmission module MR03 type

High power radio transmission module MR03 type High power radio transmission module MR03 type User s manual CONTENTS 1. APPLICATION...3 2. MR03 MODULE SET...4 3. INSTALLATION...4 3.1 Module assembly...4 3.2 Connection diagrams...5 3.3 Connection way

More information

RHS SERIES RH Set Point Controller/Probe

RHS SERIES RH Set Point Controller/Probe RHS SERIES RH Set Point Controller/Probe Publication Date: April 2005 Document Number: RHS-1-900-01 Rev B This owner s manual was as current as possible when this product was manufactured. However, products

More information

Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series. Installation, Set-Up and Operation Manual

Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series. Installation, Set-Up and Operation Manual SCALE WORKS, INC. Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series (Remote Junction Box) Installation, Set-Up and Operation Manual Cambridge Scale Works, Inc. P.O. Box 670 Honey Brook, PA.

More information

CDT. Service and Installation Manual. Manual Revision Oct 2014

CDT. Service and Installation Manual. Manual Revision Oct 2014 CDT Service and Installation Manual Manual Revision Oct 2014 2014 Cimarron Technologies Corp., Escondido, CA, USA. All rights reserved. No part of this manual may be reproduced in any way without the express

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

UCM-60 / UCM-60DL Technical Description. Revision 1.10

UCM-60 / UCM-60DL Technical Description. Revision 1.10 UCM-60 / UCM-60DL Technical Description Revision 1.10 Table of contents 1 Document Scope... 1 1.1 Parameters... 1 1.2 Configurations... 1 1.3 Sensors... 1 1.4 Microprocessor... 2 1.5 Communication... 2

More information

Programmable K-Factor Scaler B and Programming Software Kit B

Programmable K-Factor Scaler B and Programming Software Kit B Programmable K-Factor Scaler B220-885 and Programming Software Kit B220-900 INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

Radio Remote(s) (Installation Manual)

Radio Remote(s) (Installation Manual) Radio Remote(s) (Installation Manual) 87 Progress Avenue, Tyngsboro, MA 01879, USA Phone (978) 649-4ECU Fax (978) 649-8363 http://www.qtiusa.com Trademarks, Version, Printing, and Copyright Trademarks

More information

HIGH RESISTANCE MEASUREMENT ACCESSORIES

HIGH RESISTANCE MEASUREMENT ACCESSORIES HIGH RESISTANCE MEASUREMENT ACCESSORIES Complete Selection of Measurement Accessories for Your Teraohmmeters andteraohm-bridge Meters! 65326 Lead Set The 65326 Lead set is used with either the 6530 TeraOhm-Bridge

More information

Earth Fault Indicator EFI-BLZ-50 User Manual

Earth Fault Indicator EFI-BLZ-50 User Manual Earth Fault Indicator EFI-BLZ-50 User Manual CONTENTS SAFETY NOTICE.................................................................................... 3 1 OVERVIEW......................................................................................

More information

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OWNER S MANUAL Model 5100F RF POWER AMPLIFIER 0.8 2.5 GHz, 25 Watts Ophir RF 5300 Beethoven Street Los Angeles, CA 90066

More information

Precipitation Monitor ,

Precipitation Monitor , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

AC/DC Current Oscilloscope Probe Model SL261

AC/DC Current Oscilloscope Probe Model SL261 AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

NEW TOUGHEST WIND SENSORS THE WORLD S  1:2 F T 74 2 D ATA S H E E T NEW S U R FA C E M O U N T D E S I G N E D F O R I N T E G R AT I O N THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM 1:2 PROVEN IT LOOKS DIFFERENT BECAUSE IT IS DIFFERENT

More information

Temp. & humidity indicator

Temp. & humidity indicator Temp. & humidity indicator AH8008 Product Manual www.aosong.com 1 Product Overview AH8008 handheld multi-function temperature and humidity instrumentation consists of two parts: the AH8008 instrument and

More information

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO. 990-60700-9801 GEOTECH INSTRUMENTS, LLC 10755 SANDEN DRIVE DALLAS, TEXAS 75238-1336 TEL: (214) 221-0000 FAX: (214) 343-4400

More information

Model 12PR1A. User Manual

Model 12PR1A. User Manual 12 Volt Ultra-Portable Antenna Rotor System Single Axis Model 12PR1A User Manual Document Rev 1.1 Copyright 2013-14 Portable Rotation Patent Pending Page 1 Warranty All products sold by Portable Rotation

More information

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Giga-tronics GT-1050A Microwave Power Amplifier GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Operation Manual

More information

ISD4000 Depth & Temperature Sensor With Optional AHRS

ISD4000 Depth & Temperature Sensor With Optional AHRS ISD4000 Depth & Temperature Sensor With Optional AHRS Installation & Operation Manual Revision: 1.5 Date: 27/01/17 Impact Subsea Ltd T. +44 (0) 1224 460 850 E. info@impactsubsea.co.uk W. www.impactsubsea.com

More information

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

COMBILOG ANTENNA MODEL AC MHz. rev: 0202 COMBILOG ANTENNA 30-2000 MHz MODEL AC-220 rev: 0202 WARRANTY All equipment manufactured by Com-Power Corporation is warranted against defects in material and workmanship for a period of two (2) years from

More information

SMARTALPHA RF TRANSCEIVER

SMARTALPHA RF TRANSCEIVER SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design

More information

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product

More information

Ultrasonic Wind Sensors WS425 USER'S GUIDE

Ultrasonic Wind Sensors WS425 USER'S GUIDE Ultrasonic Wind Sensors WS425 USER'S GUIDE M210361en-B May 2004 PUBLISHED BY Vaisala Oyj Phone (int.):+358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages

More information

ictalk User Guide May 19, 2015 ictalk Smart Projectors

ictalk User Guide May 19, 2015 ictalk Smart Projectors ictalk User Guide May 19, 2015 ictalk Smart Projectors Ocean Sonics Ltd. Hill House, 11 Lornevale Road, Great Village, NS, B0M 1L0 Canada Phone: +1 902 655 3000 www.oceansonics.com Table of Contents Table

More information

LC-10 Chipless TagReader v 2.0 August 2006

LC-10 Chipless TagReader v 2.0 August 2006 LC-10 Chipless TagReader v 2.0 August 2006 The LC-10 is a portable instrument that connects to the USB port of any computer. The LC-10 operates in the frequency range of 1-50 MHz, and is designed to detect

More information

Specifications. Important Safety Information

Specifications. Important Safety Information Specifications Tire Rim Capacity 4 to 12 Rim Height 16 (2) Bead Breaker Handles 21 Long Includes Aluminum Centering Cone (2) Nylon Spacers Important Safety Information 1. Do not exceed max. tire capacity.

More information

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1586-06 RF Attenuator May 2009 Rev A 1 2 3 12.5 53.5 16.3 MODEL 1586 RF ATTENUATOR CROSS TECHNOLOGIES INC. EXECUTE PS1 PS2 Data, drawings, and other material contained herein are

More information

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free 2001A 200KHz Function Generator Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WARRANTY Global Specialties

More information