Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.
|
|
- Byron Phillips
- 6 years ago
- Views:
Transcription
1 Cable I.D. Live Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded i
2 ii
3 TABLE OF CONTENTS Warning Description Battery Test Types of cables that cane be tested Secondary - Street Light Cables CATV and Telephone Jacketed Primary Non-Jacketed Primary Service and Warranty iii
4 WARNING 1. ALL CABLES ARE CONSIDERED ENERGIZED UNLESS THEY ARE VISIBLY INSPECTED TO BE GROUNDED. 2. BEFORE A HIGH VOLTAGE CABLE CAN BE CUT, IT MUST BE SPIKED. DESCRIPTION This Cable I.D. Live system will allow the identification of one cable from another, in or out of the trench, live or dead if the following instructions are followed. It also must be understood that there are conditions of a cable under test that may be un-known, and those conditions could prevent accurate readings. Your Cable I.D. Live system consists of three items. One receiver and two inductive couplers. One coupler has a cord on it and one coupler is wireless. The wireless coupler is the transmitting coupler. When the wireless coupler is installed around a conductor, a tracing tone is also available between the two ground rods on that cable. Any of the Aqua-Tronics active frequency cable locating receivers can be used to trace the route of that cable under test. Both couplers have a hot stick ring on one side that allows the jaws to be opened and closed using a hot stick. A ¼-20 threaded insert is at the back end so a threaded extension rod can be installed. With a cord tied to the hot stick ring, the opening and closing of the coupler jaws can be remote if a hot stick is not available. BATTERY TEST Before starting a cable identification, check all batteries. THE WIRELESS COUPLER Turn the coupler on. It has a red LED that will blink every 3 or 4 seconds if the battery is good. If the LED fails to blink, remove the four screws holding the battery cover in place. Replace the 9 volt radio battery with any 9 volt alkaline battery that will fit. (Some off shore made batteries may be just a little large for the compartment) 1
5 THE RECEIVER Turn on the receiver with the on/off switch. After the receiver has completed its start-up self test, the word GAIN will appear in the upper left corner of the display. Push the spring loaded battery test switch. The battery voltage will be provided in the lower center of the display. In the upper right corner of the display, a battery symbol will appear. If the battery voltage drops below the proper level for operation, the battery symbol will start flashing. The battery voltage is also displayed for a few seconds during the start-up self test. To replace the batteries, remove the battery cover at the back end of the handle. Unsnap the battery connector and remove the battery holder. Replace with Alkaline AA batteries for longer life. 6 each. ONLY USE THOSE INDUCTIVE COUPLER MODELS THAT ARE SUPPLED WITH THE INSTRUMENT FROM AQUA-TRONICS, INC. Other couplers may look similar, but the I.D. Live receiver is not built for their use and their accuracy will not allow proper identification. TYPES OF CABLES THAT CAN BE TESTED The methods used to identify one cable from another is slightly different for shielded and unshielded cables. As a result, this manual is divided into three parts. Insulated Cables. --- Secondary and street light cables. Low voltage Shielded Cables --- Cable T.V. and telephone. Jacketed High Voltage Primary Cables Unlike other methods of applying signal which can place the same amount of signal on every circuit that is electrically connected, the transmitting coupler signal will go to the first ground it can find on both sides of the coupler. The signal will divide down and be much less on the other conductors that are connected to the same ground. The major portion of the signal will be on the conductor the wireless coupler is clipped around, between the grounds at both ends. If the signal finds a wire connection of two or more conductors at some junction point before it finds the ground, the signal will divide down with much smaller signal being on each conductor. See Fig. 1 When installing the wireless inductive coupler to a cable, the cable must be inside the coupler ring with the coupler closed and the cable must be grounded at both ends. The ground can be through a load on energized cables. This also applies to the conductor of a de-energized primary cable. The neutral and conductor must be 2
6 grounded at both ends. If the coupler cannot see a ground at both ends, it will not apply a signal to the conductor. When making a cable I.D., measure each cable in question. Adjust the receiver gain control for a mid-scale reading on the display for each cable. Once the gain control is set for a mid-scale reading on the cable that has the most signal, all of the other cables under test will have much less signal at that gain setting. That is the cable the wireless transmitter is around. SECONDARY - STREET LIGHT CABLES. Place the wireless transmitting coupler around the meter riser conduit, or a single conductor. Turn the coupler on with the low-high power switch on low. High power can be used but in most cases it is not required and low power will reduce the chance of inducing signal into other circuits. From where the transmitting coupler is installed, signal will travel in both directions to its respective ground. This will allow the receiving coupler to be used at any access point between the two grounds. Turn on the receiver and install the receiving inductive coupler plug into the phone jack provided. The receiver is now ready to take readings. In the upper left corner of the display above the word GAIN, a number will appear. This number from 0 to 100 is the percentage number of where the sensitivity control is set. A reading of 25 would be 25% of the sensitivity control use. This will allow the operator to identify the different signal levels on each cable under test. Place the receiving coupler around each cable one at a time. The cable with the highest signal reading on the display will be the cable the wireless transmitter is 3
7 around. All of the other cables could have signal on them, but the signal level will be much lower. With the receiving coupler around the first cable being tested, adjust the sensitivity control for a mid-scale bargraph reading. If the second cable has a lower or equal reading, leave the sensitivity control where it is and move the coupler to the next cable. If the reading on the second cable is higher than the first cable, adjust the sensitivity control down for the mid-scale bar-graph reading. When the cable has been found that has the mid-scale reading and all other cables under test have a much lower reading or no signal reading at all at that gain setting. The cable with the highest reading is the cable the wireless transmitting coupler is clipped around. A numerical signal level is also positioned in the lower center of the display below the bar-graph. This numerical number is tied to the bargraph and will provide the highest numerical reading on the correct cable. EXAMPLE With the wireless coupler around a meter riser at the house, the coupler would be around both hot legs and the neutral. At the transformer, the receiving coupler will identify both hot legs and the neutral going to that meter. See Fig. 2 IF THE METER HAS BEEN REMOVED, ONLY THE NEUTRAL CAN BE IDENTIFIED. NO SIGNAL CAN BE PLACED ON THE TWO HOT LEGS BECAUSE THEY ARE ISOLATED AND THE TRANSMIITER CANNOT SEE A GROUND AT THE ISOLATED END. CATV and TELEPHONE These cables have a metallic sheath around the outside of the internal conductors. Since the sheath is also a magnetic shield to radio waves, the transmitting coupler must be placed around the outer jacket of the CATV or Telephone cable that includes the sheath. Since the sheath is a magnetic shield, all receiver readings must be made having the receiving coupler around the outer jacket of the entire cable. See Fig. 3 4
8 If for some reason the transmitting coupler was placed around the internal conductors that did not include the sheath, the receiving antenna would only see signal on the conductors at the far end. Signal would not be available anywhere along the cable route because of the sheaths magnetic shielding. JACKETED PRIMARY The concentric neutral has a ground rod at both ends and a semi-conductive jacket around the neutral. Since the neutral is isolated from the soil, the transmitting coupler can be placed around the outer jacket and the signal will transmit in both directions to the two ground rods. See Fig. 4 In Fig. 4, the signal should be measured at position # 2 for all cables under test. Position 3 could give incorrect 5
9 readings. In Fig. 5, the situation is different than Fig. 4 The transmitting coupler is now around the conductor at position # 1. The receiving coupler in position # 3 will receive the strongest signal because of neutral shielding. NOTE: If the transmitting coupler is placed around the entire cable, the receiving coupler must be placed around the entire cable. If the transmitting coupler is placed around the conductor only, the receiving coupler must be placed around the conductor only for all cables under test. There are several conditions that could limit the ability to make a positive cable identification. # 1. Neutral pigtails touching other pigtails between the neutral break out and the ground bus wire at the base of a transformer. Signal will divide where it touches another conductor before it finds the ground rod. See Fig. 6 On the cable the transmitting coupler is on, the pigtail should go to the ground bus at the base of the enclosure or ground rod without touching other pigtails. #2. A non-jacketed section of primary spliced into a jacketed primary. Even though the transmitting coupler is around a jacketed cable, at the point where the bare neutral of the non-jacketed cable is touching the soil may look like a ground rod to the signal. All the operator may see is a jacketed cable at both ends and unaware of the non-jacketed section. The readings taken will not be what the operator is looking for in proof positive identification. 6
10 Because of the two mentioned and many more problems that could exist. All cables are considered energized unless they have been physically grounded and all cables are spiked before they are cut. A good rule of thumb is ---- IF READINGS BEING TAKEN ARE NOT TURNING OUT AS TO WHAT THE OPERATOR THINKS THEY SHOULD BE, STOP ALL TEST AND REVIEW THE SET UP. MOST OF THE TIME, THE OPERATOR WILL FIND A PROBLEM IN THE SET UP SUCH AS THE TRANSMITTER NOT BEING ON THE CABLE THEY THOUGHT IT WAS ON. NON-JACKETED PRIMARY This instrument should not be used on non-jacketed primary cables because of the unknown condition of the insulation that could expose the operator to a live conductor arc. Non-jacketed high voltage cables have three main problems that will prevent identification of one phase from another. For this reason, Aqua-Tronics, Inc. recommends that cable identification is not performed with this instrument on unjacketed primary cables. 3 examples are given, but there could be many others reasons. # 1. The integrity or condition of the insulation cannot be verified and there is a danger of causing a neutral to conductor short when physically handling bare neutral cables. # 2. The bare neutral is in contact with the soil along the route of the cable and signal wants to find the first ground available when inductive couplers are applying signal. The neutral is in contact with the soil at the point where it leaves a conduit or a transformer and the signal will no longer provide accurate readings beyond the first ground available. # 3. The bare neutral of one cable is touching the bare neutral of the other phases along the route or the pigtails are touching between the neutral break out and ground bus connection at the base of the transformer. As a result, the signal is dividing down and will not be the correct amount for a cable comparison. 7
11 SERVICE AND WARRANTY INSTRUMENT SERVICE If for any reason assistance is needed with this instrument, contact the nearest Aqua- Tronics, Inc. sales outlet. You may also write, call, or directly to Aqua- Tronics, Inc. and provide full details of your problem or needs. You can find your nearest sales office at under REP LOCATOR. WARRANTY All Aqua-Tronics products are warranted against defective materials and workmanship. The Cable I.D. Live receiver and inductive couplers have a one year warranty period from date of purchase. Aqua-Tronics, Inc. will repair or replace all products which prove to be defective during the warranty period. All warranty repair will take place at our manufacturing plant or at one of our field service centers. The decision of determining warranty defects from abuse or breakage, and where the instrument is to be repaired, lies with Aqua-Tronics, Inc. If products are sent to Aqua-Tronics, Inc. for service, please send it pre-paid. If the service is covered under warranty, the product will be returned pre-paid. No other warranty is provided or implied. 8
12 9
STAFF User Manual. Manual Part #
STAFF User Manual Manual Part # 030-00085-00 Introduction Congratulations on the purchase of your new STAFF Secondary Fault Locator. The STAFF is specially designed to detect conductor to earth/ground
More informationPOWER TRACE TM TASCO, INC.
POWER TRACE TM Instruction Manual PTL610 TASCO, INC. HOW YOUR POWER TRACE TM OPERATES The Power Trace TM is composed of two primary components: the Receiver and the Transmitter. When the Transmitter is
More information2011 / Circuit Tracer
INSTRUCTION MANUAL 2011 / 00521 Circuit Tracer Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 52044992 2008 Greenlee Textron
More informationDynatel 2250E/2273E Advanced Cable and Fault Locator
Dynatel 2250E/2273E Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6500-7-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...
More informationAT-4000 Advanced Tracer User s Manual
AT-4000 Advanced Tracer User s Manual Amprobe thanks you for purchasing the AT-4000 Advanced Tracer. For your safety, please read this instruction manual in its entirety. LIMITED WARRANTY VÉÇzÜtàâÄtà ÉÇá4
More informationMICROTOOLS MICRONETBLINK KIT
MICROTOOLS MICRONETBLINK KIT MicroNetBlink TM MicroProbe TM User Guide Manuel Utilisateur Benutzer Handbuch Manuale per l'utente Guía del Usuario Manual do Utilizador 2947-4511-01 Rev. 01 11/01 2001 Fluke
More informationUser Manual 8880 Series Fault Finding & Locating Kit
User Manual 8880 Series Fault Finding & Locating Kit Model 8880PLS STAFF Model 8880PLS HVDFF Manual Part # 030-00085-00 Rev E Table of Contents General Information Introduction...............................................
More informationAT Advanced Wire Tracer. Users Manual
AT-1000 Advanced Wire Tracer Users Manual AT-1000 Advanced Wire Tracer English Users Manual AT1000_Rev001 2008 Amprobe Test Tools. All rights reserved. Limited Warranty and Limitation of Liability Your
More informationWireMaster Coax BNC PN: Rev C 2/13
WireMaster Coax BNC Instruction Manual PN: 3274 84-868 Rev C 2/13 Table of Contents Features...... 2 Introduction... 3 Warnings and Cautions... 3 Specifications...4 Typical Cable/Wire Resistances...5 Control
More informationAT-4000 Series. Advanced Wire Tracer. Users Manual
AT-4000 Series Advanced Wire Tracer Users Manual AT-4000 Series Advanced Wire Tracer English Users Manual AT4000CON_Rev001 2008 Amprobe Test Tools. All rights reserved. 1 Limited Warranty and Limitation
More informationTAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.
TAG5000 WIRELESS PHASER Instruction Manual TM HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS 60085 U.S.A. PHONE 847.473.4980 FAX 847.473.4981 website: www.hdelectriccompany.com DESCRIPTION
More information8873 v3 Pathfinder Locator User Manual
8873 v3 Pathfinder Locator User Manual Manual Part # 030-00100-00 Rev B Table of Contents General Information Introduction...2 Prepare for Use....2 Receiver Operation.......................................
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand
More informationDynatelTM Cable Locator. Operators Manual. October Revision A
DynatelTM 2210 Cable Locator Operators Manual October 1996 78 8097 5171 8 Revision A 3M TM Dynatel TM 2210 Cable Locator Operators Manual The information in this manual is proprietary to 3M and may not
More informationPathfinder. Instruction Manual for: PF620 Circuit Tracer Kit
Pathfinder Instruction Manual for: PF620 Circuit Tracer Kit Table of Contents Page Safety Considerations...3 Introduction...4 Specifications...5 Theory of Operation...6 Single Phase Circuits Locating Circuit
More informationUser Manual Pathfinder Precision Locating System
User Manual Pathfinder Precision Locating System Manual Part # 030-00113-00 Copyright Copyright 2017 RYCOM Instruments, Inc. All rights reserved. No part of this manual may be reproduced, copied, modified
More informationf i r e - p a r t s. c o m
Model: CON 1001-1 INSTALLATION AND OPERATING INSTRUCTIONS SINGLE-FUNCTION WIRELESS REMOTE CONTROL SYSTEM FOR OPERATING VALVES WITH ON/OFF LATCHING SOLENOIDS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION
More informationOwner s Manual DKW-3 GT. Wireless VHF Instrument System
Owner s Manual DKW-3 GT Wireless VHF Instrument System Contents Introduction... 2 System Features... 2 Operation... 3 Specifications... 6 Service Information... 6 Warranty... 7 Introduction Thank you for
More informationSURETRACE CIRCUIT TRACER YOUR IDEAL TROUBLESHOOTING SOLUTION. DESIGNED TO FIND EVERYTHING, WHILE SAVING YOU TIME AND MONEY.
SURETRACE CIRCUIT TRACER YOUR IDEAL TROUBLESHOOTING SOLUTION. DESIGNED TO FIND EVERYTHING, WHILE SAVING YOU TIME AND MONEY. FINDS... BREAKERS AND FUSES SPLICE ERRORS DEAD SHORTS WIRES IN WALLS, CEILINGS,
More informationPro871C Cable Locator Operating Instructions
Pro871C Cable Locator Operating Instructions WARNING Read and understand the instructions before operating this unit. Failure to do so could lead to injury or death. The Armada Technologies Pro871C wire
More informationOPERATOR S MANUAL. Directional Acoustic Detector S.D.A.D. II by Aqua-Tronics, Inc.
OPERATOR S MANUAL Directional Acoustic Detector S.D.A.D. II by Aqua-Tronics, Inc. www.aquatronics.com FIGURE 1 Electronics Showing Controls 1 through 5 1. On/Off (Push for On) (Hold ~ 2 sec. for Off) 2.
More informationInstallation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION
Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant
More informationPHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S
PHASE ROTATION METER a n d A C C E S S O R I E S Operating and Instruction Manual HD ELECTRIC COMPANY 1 4 7 5 L A K E S I D E D R I V E WA U K E G A N, I L L I N O I S 6 0 0 8 5 U. S. A. PHONE 847.473.4980
More informationATEX CIE-2 x 2 x 0.75 mm 2 -Twisted Pair (TP)-Cable
ATEX CIE-2 x 2 x 0.75 mm 2 -Twisted Pair (TP)-Cable Cable routing and connection instructions For signal transmission from PXD Sensors and/or AISC Equipment (Suppressors) to the Control Panel, preferably
More information900 MHz Digital Wireless Indoor/Outdoor Speakers
4015007 900 MHz Digital Wireless Indoor/Outdoor Speakers User s Manual This 900 MHz digital hybrid wireless speaker system uses the latest wireless technology that enables you to enjoy music and TV sound
More informationInstallation & Operation Manual SAGA1-K Series Industrial Radio Remote Control
Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2
More informationSCREENING EFFICIENCY TESTER Model 271
SCREENING EFFICIENCY TESTER Model 271 Operating Manual 11/1/05 1 1.0 INTRODUCTION Conductive suits are worn by power company personnel for protection while performing maintenance on live wire transmission
More informationFar End Device II Model 1342
3 Far End Device II Model 1342 Operating Instructions Optimized for ADSL2+ May 2007 78-8130-0876-6-C Table of Contents Introduction...3 Power-up...4 Connecting the 3M Far End Device II...5 Installing,
More informationAT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok
AT-3500 Underground Cable/Pipe Locator System Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok For detailed specifications and ordering info go to www.testequipmentdepot.com
More informationL1070 and L1071 Portable Locator Catalog No and
Instruction Manual AVTM651070 for L1070 and L1071 Portable Locator Catalog No. 651070 and 651071 High Voltage Equipment Aparato de Alto Voltaje Read the entire manual before operating. Antes de operar
More informationModel: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS
Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS INTRODUCTION IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE This remote control system
More informationUSER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationSureTest Circuit Tracers Instruction Manual
SureTest Circuit Tracers Instruction Manual #61-954 #61-956 #61-958 Table of Contents Safety Information...3 Introduction...4 Callouts of Features Transmitter...5 Receiver...6 Test Lead Kit...8 Inductive
More informationProduct Information and Instructional Presentation
Product Information and Instructional Presentation CAUTION: Before Bf using the FireCraft tracer you must read and fully understand d this presentation and the operating manual provided at the time of
More informationElectro-Mech Scoreboard Co. Product Guide
Electro-Mech Scoreboard Co. Product Guide 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7846 Fax: (478) 864-0212 www.electro-mech.com Table of Contents Introduction to the ScoreLink System...3
More information1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS
1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS, DO NOT ATT TO INSTALL OR OPERATE INTRODUCTION This SKYTECH remote control system was
More informationUAT-600 Series. amprobe.com
UAT-600 Series Underground Utilities Locator Accurately and safely pinpoint underground utilities before you dig Accidentally hitting a utility line during a project can lead to costly repairs and create
More information5001 INSTALLATION AND OPERATING INSTRUCTIONS
5001 INSTALLATI AND OPERATING INSTRUCTIS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATI INSTRUCTIS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTI This SKYTECH remote control system was developed to
More informationBlack Oak / Light Oak / Cherrywood Wireless Panel Speaker
4015115/4015116/4015117 Black Oak / Light Oak / Cherrywood Wireless Panel Speaker With Infrared Remote Control USER GUIDE For use with: Introduction These 900 MHz stereo wireless speaker system uses the
More informationDriveway Alarm INSTALLATION MANUAL
WIRELESS ACCESS CONTROLS Driveway Alarm INSTALLATION MANUAL Mounting post Transmitter Receiver Transformer Sensor Kit Includes: Transmitter Module Sensor Receiver Transformer Mounting post (3 pieces) Installation
More informationTelephone Cable Locating Techniques
Chapter 2 Telephone Cable Locating Techniques Introduction Read Chapter One of this manual to learn more general information about each of the following signal application methods. The following paragraphs
More informationLAN/Length Cable Tester TCT-2690 Pro
User Manual LAN/Length Cable Tester TCT-2690 Pro Introduction 2 Features 2 Specifications 3 Instructions for Operation 4 LAN Mode 4 Memory Mode 7 Low Battery Mode 8 TEL Mode 8 COAX Mode 10 TONE Mode 11
More informationAT-7000 Advanced Wire Tracer
AT-7000 Advanced Wire Tracer Wire Tracing Reinvented Get accurate results in minutes with new features and technologies that simplify wire tracing and breaker identification. The s patented Smart Sensor,
More informationPLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A
PLA-240 Small Room Loop Amplifier System USER Manual MAN 211A Overview Thank you for purchasing the PLA 240 Small Room Loop Amplifier System. The PLA 240 Loop System provides a practical solution for hearing
More informationSP GHz Digital Wireless Speakers. User s Manual. Please read before using the equipment. Please visit for details.
SP1390 2.4GHz Digital Wireless Speakers User s Manual Please read before using the equipment. Please visit www.promowide.com for details. INTRODUCTION This 2.4G digital wireless speakers system uses latest
More information900MHz Digital Hybrid Wireless Outdoor Speakers
4015004 900MHz Digital Hybrid Wireless Outdoor Speakers User s Manual This 900 MHz digital hybrid wireless speaker system uses the latest wireless technology that enables you to enjoy music and TV sound
More informationUTILITY LOCATING EQUIPMENT
RIDGID SEEKTECH LOCATING RECEIVERS RIDGID locating receivers feature an easy-to-use visual mapping display that allows you to locate utility lines and sondes/beacons with confidence. Use with a SeeSnake
More informationCABLE TRACER & PHONE TESTER / GENERATOR
CABLE TRACER & PHONE TESTER / GENERATOR 183 CB-A Amplifier Probe INSTRUCTION MANUAL Amplifier Probe Amplifier Probe 183 CB-A Figure 1 Amplifier Probe 183 CB-A Figure 2 Features The Amplifier Probe is designed
More informationF I S H E R R E S E A R C H L A B O R A T O R Y
TW-82 DIGITAL LINE TRACER Operating Manual F I S H E R R E S E A R C H L A B O R A T O R Y CONTENTS Introduction...pg. 3 Transmitter...pg. 4-5 Receiver...pg. 6-8 Operating Instructions...pg. 9 Specifications...pg.
More informationTraceMaster. Pipe and Cable Locator Multi-Frequency Receiver and Radio Linked to Transmitter. Instruction Manual
TraceMaster Pipe and Cable Locator Multi-Frequency Receiver and Radio Linked to Transmitter Instruction Manual Schonstedt Instrument Company 100 Edmond Road Kearneysville, WV 25430 888-32-TRACE Tel.: (304)
More informationSchooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21
Schooners II Weatherproof Wireless 900MHz Speaker System User Guide Model no.: GDI-AQSHR200 / AQSHR21 IMPORTANT: Please read your User s Guide before using your system INTRODUCTION Your SCHOONERS II speaker
More informationInstallation Instructions
Installation Instructions Garage Door Opener Radio Controls Model 5010 (300 mhz) \ 5012 (310 mhz) Single Button Transmitters Model 5100-01 (300 mhz) \ 5102-01 (310 mhz) Receivers WARNING: Disconnect operator
More informationModel 1791 VHF Radio User's Manual
Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power
More informationThis manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.
This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters. The Wavetrak WT-RC-Ex receiver kit comes with the following pieces of equipment:
More informationRock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41
Rock Sounders Weatherproof Wireless 900MHz Speaker System User Guide Model no.: GDI-AQRCK400 / AQRCK41 Please read before using the equipment IMPORTANT: Please read your User s Guide before using your
More informationGPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.
GPNP Inc. NT384 NT1 User Manual Revision 1.00 17/6/2002 Information in this guide is subject to change without notification. Copyright 2002 GPNP Inc. U.S.A. IMPORTANT SAFETY INSTRUCTIONS When using your
More informationCABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit
CABLE TESTER Models CA7024, CA7026 & CA7028 Call toll free (800) 537-0351 or visit www.allspec.com Hand-held LAN Cable Mapping and Troubleshooting Tester (Model CA7028) Hand-held Alphanumeric TDR (Time
More informationNational Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002
National Radio Astronomy Observatory Socorro, NM 87801 EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable T. Baldwin June 05, 2002 Summary Double-armor triple-sheath fiber optic cable will be
More informationQUICK TESTER FOR TRANSFORMERS AND CAPACITORS
n 8505 QUICK TESTER FOR TRANSFORMERS AND CAPACITORS E N G L I S H User Manual Table of Contents 1. INTRODUCTION... 3 1.1 Receiving Your Shipment...3 1.2 Ordering Information...3 1.2.1 Replacement Parts...3
More informationSIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..
Copyright 2001-2017 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form Published by Geophysical Survey Systems, Inc. 40 Simon Street
More informationCoax ClarifierTM. User Manual. Test. Identify. Qualify. See video demonstrations at:
Coax ClarifierTM Test. Identify. Qualify. User Manual Coax Run Mapping Maps runs through splitters to show an accurate picture of the coax system layout using up to 4 Coax RF Remotes. Up to 12 ID Only
More informationCHANCE Proximity Voltage Indicator
Revision D 10/16 CHANCE Proximity Voltage Indicator Operating Instructions Model No. PSC4033737 For use with Capacitive Test Point through 500 kv AC NOTICE: Before operating a Chance Proximity Voltage
More informationFor Precise Volume Adjustment with Programmable Muting in Any Room
INSTALLATION & USER GUIDE For Precise Volume Adjustment with Programmable Muting in Any Room 12 STEP MUTING WALL MOUNT VOLUME CONTROL V-12M V-12M 12 STEP MUTING WALL MOUNT VOLUME CONTROL TABLE OF CONTENTS
More informationIMMS-CI-HW. Communications Controller Interface. Installation Instructions IMMS. Controller. Interface. AC From Transformer 24 VAC REM 24 VAC SEN
CI 4 Comm. IMMS-CI-HW Communications Interface POWER From Transformer Ground To REM Installation Instructions To SmartPort Sensor 1 Sensor 2 Sensor 3 From Sensors Sensor Common IMMS Interface From SI or
More informationOwner s Manual DKW-3 HT. Wireless VHF Microphone System
Owner s Manual DKW-3 HT Wireless VHF Microphone System Contents Introduction... 2 System Features... 2 Operation... 3 Specifications... 5 Service Information... 6 Warranty... 7 Introduction Thank you for
More informationModel: 5010 INSTALLATION AND OPERATING INSTRUCTIONS
Model: 5010 INSTALLATI AND OPERATING INSTRUCTIS INTRODUCTI IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATI INSTRUCTIS DO NOT ATTEMPT TO INSTALL OR OPERATE This SKYTECH remote control system was developed
More informationF AN-ASPIRATED W IRELESS T EMPERATURE/HUMIDITY S TATION
F AN-ASPIRATED W IRELESS T EMPERATURE/HUMIDITY S TATION INSTALLATION MANUAL The Fan-Aspirated Wireless Temperature/Humidity Station, referred to in this manual as the Aspirated Temp/Hum Station, combines
More informationDynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write
3 Dynatel 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write Designed to be more accurate, faster and more integrated than any other locator on the market,
More informationDOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write
3 Dynatel 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write New-to-the-world technology for locating underground utilities without any doubt. The 3M Dynatel
More informationSpecifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators
Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators PHYSICAL SPECIFICATIONS SIZE WEIGHT (H X W X D) IN. (CM) (INCLUDING BATTERIES) Transmitter 6.75 x 11.25 x 7.75 (17.2 x 28.6 x 19.7)
More informationINSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.
INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA
More information600A Clamp Meters w/tightsight Display
V 750V #61-764 #61-766 #61-768 600A Clamp Meters w/tightsight Display Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CAT.IV 600V CAT.III 1000V 600A 61-766
More informationC99-20LL System Cable P/N 40935G-06 INSTALLATION SHEET
C99-20LL System Cable P/N 40935G-06 INSTALLATION SHEET The C99-20LL Interface cable connects a Universal Gateway Wireless System with the David Clark Series 9500 Marine Intercom System, and allows the
More informationDM-46 Instruction Manual
Auto Meter Products Inc. Test Equipment DM-46 Instruction Manual Automotive Multimeter and Inductive Amp Probe The DM-46 is the auto industry s answer to pocket portability in a 20 2650-1552-00 3/8/11
More informationWisconsin Contractors Institute Continuing Education
IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you
More informationINDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...
INDEX PREFACE... 1 CAUTIONS... 2 STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(1)... 5 (Transmitter Unit.) OPERATION OF TRANSMITTER(2)... 6 (Operation Panel, LCD Display of
More informationM2/M2A AC-DC Power Supply Operator s Manual
M2/M2A AC-DC Operator s Manual Part Number: 71-0247RK Revision: A Released: 5/18/15 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warranties gas alarm equipment sold by us to be free from
More informationCom-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide
Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide Topic Introduction 1 Tool Requirements 1 Trouble Shooting Check List 1 Page(s) Lost communications to controller(s)
More informationUser Manual. ProRF Encoder Transmitter & Receiver
User Manual ProRF Encoder Transmitter & Receiver WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original
More informationObsolete Document. Dynatel
3 Dynatel 2273ME Cable/Pipe and Fault Locators 2273ME-iD Cable/Pipe/Fault and Marker Locators with id Read/Write 2250ME Cable/Pipe Locators 2250ME-iD Cable/Pipe and Marker Locators with id Read/Write New-to-the-world
More informationArmada Technologies Pro800D Hi-Power Wire and Valve Locator. Operating Instructions
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Armada Technologies Pro800D Hi-Power Wire and Valve Locator Armada T echnologies Operating P ro800d Instructions
More informationDakota Alert. WPT-3000 Wireless Probe Transmitter. Owner s Manual
Dakota Alert WPT-3000 Wireless Probe Transmitter Owner s Manual Warnings This device complies with Part 15 of the FCC rules, operation of this device is subject to the following conditions: 1. This device
More informationSDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01
SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING Rev. 01 This specification is property of SEC and subject to change or modification without any notice
More informationVM-22. VHF Wireless Microphone System. Operating Instructions
VOLUME VHF Wireless Microphone System VM- Operating Instructions VOLUME VHF Wireless Receiver RF AF AF RF Thank you for purchasing this unit. To make full and effective use of this unit, please read this
More informationFor detailed specifications and ordering info go to
For detailed specifications and ordering info go to www.testequipmentdepot.com ECB50A, ECB50A-E, ECB50A-FGIS Circuit Breaker Finder and AC Cable Tracer User Manual For detailed specifications and ordering
More informationLeica DIGISYSTEM TM Safe and fast location of underground services
Leica DIGISYSTEM TM Safe and fast location of underground services Find it or avoid it the Leica DIGISYSTEM is your Key Why locate Construction sites have many and varied buried services and utilities.
More information2-wire level transmitter
Badger Meter Europa GmbH 2-wire level transmitter Model L2xx INSTALLATION AND OPERATION MANUAL July 2002 Version UF-L2xx-07/02-e Contents Contents Page 1. Installation 1 1.1 Mounting the instrument 1 1.2
More informationUser's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32
User's Guide Wireless AC Circuit Identifier Models RT30 and RT32 Introduction Congratulations on your purchase of Extech s Model RT30 (914Mhz) or RT32 (869MHz) Wireless AC Circuit Identifier. The detector
More informationAppearance of device and accessories may vary.
Mobile 4G Smart Technology Signal Booster Contents: How it Works.... 1 Before Getting Started.... 2 Quick Installation Overview.... 2 Installing the Outside Antenna.... 2 Installing the Low-Profile Antenna....
More informationPAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.
PAMS Portable Attenuation Measurement System User s Manual The solution for making easy shielding effectiveness measurements. 310-010042-001 TABLE OF CONTENTS Warranty Statement 1 Chapter 1 General Information
More informationINSTRUCTION MANUAL. March 11, 2003, Revision 3
INSTRUCTION MANUAL Model 701A Stimulator March 11, 2003, Revision 3 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora, Ontario, Canada L4G 3V7 Tel: 1-905-727-5161
More informationRadiodetection. Fundamental principles and techniques in buried utility location
Fundamental principles and techniques in buried utility location Canada 344 Edgeley Blvd. Unit 34 Concord, Ontario L4K 4B7 1-800-665-7953 Pipe and Cable Locators don't find pipes and cables...? 2 ...they
More information3M Dynatel Cable/Pipe/Fault Locator 2550/2573 Series
3M Dynatel Cable/Pipe/Fault Locator 2550/2573 Series Operator s Manual 2550 Pipe/Cable Locator 2550-iD Pipe/Cable and Marker Locator 2573 Cable/Pipe/Fault Locator 2573-iD Cable/Pipe/Fault and Marker Locator
More informationCABLE & PIPE LOCATOR USER S MANUAL
CABLE & PIPE LOCATOR USER S MANUAL CL10 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction........................................................
More informationFletcher F-3000 / F-3100 Accessory Laser Kit
Fletcher F-3000 / F-3100 Accessory Laser Kit Shown Assembled on F-3000 Machine Product Warranty The Fletcher-Terry Company warrants the product purchased to be free from defects in parts and workmanship
More informationSP980. Cordless Stereo 863MHZ. Speaker System. User s Manual INTRODUCTION FEATURES. Please read before using the equipment
SP980 Cordless Stereo 863MHZ Speaker System INTRODUCTION This 863 MHz stereo wireless speaker system uses latest wireless technology that enables you to enjoy music and TV sound anywhere inside or outside
More informationTW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y
TW-82 ACCESSORIES 3 Inch Coupling Clamp CCLAMP-3 Useful for in-service and electrical power line tracing when a metal-to-metal hookup is not possible TW-82 DIGITAL LINE TRACER 5 Inch Coupling Clamp CCLAMP-5
More informationP/N: TMPRO3PLUS SERVICE AND WARRANTY
SERVICE AND WARRANTY Should your unit ever require service, please do not return the product to your dealer. Please call the number below for special instructions on shipping and handling. Please call
More informationUser Guide S1230 / SS1230 / SW1230 Mity Box Passive / Amplified / Wireless Speaker
User Guide S1230 / SS1230 / SW1230 Mity Box Passive / Amplified / Wireless Speaker Thank you for choosing the S1230 / SS1230 / SW1230 Mity Box Speaker from AmpliVox Portable Sound Systems. We are excited
More informationTT-07 TAP TRAP INSTRUCTION MANUAL TT-07 GENERAL INFORMATION
Size: 5.5 x 2.75 x 1 Weight: 9 oz. Batteries: 9 volt transistor type. TT-07 TAP TRAP INSTRUCTION MANUAL TT-07 GENERAL INFORMATION The Tap Trap can detect both series and parallel wiretaps that are attached
More information