Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

Size: px
Start display at page:

Download "Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L."

Transcription

1 /9 TECHNICAL SPECIFICATIONS VOLTAGE LOW-POWER TRANSFORMER VS- Rev. Date Revision Description Prepared by Checked by Approved by 0 24/09/2 First issue A. Peretto L. Peretto 24/06/6 All text review E. Scala L. Peretto J. L. Kennedy

2 2/9 INDEX. SCOPE OF THE DOCUMENT 4 2. VS- DESCRIPTION 4 3. REFERENCE DOCUMENTS 6 4. OPERATIONAL CHARACTERISTICS of ALTEA VS SERVICE CONDITIONS OF THE ALTEA VS Service conditions Ambient air temperature Altitude Vibration and earth tremors Service conditions for the ALTEA VS Earthing system Materials Safety 0 6. RATING OF THE LOW-POWER VOLTAGE TRANSFORMER VS Standard values of rated voltages Rated primary voltage Rated secondary voltage Standard values of rated voltage factor ku Earthed low-power voltage transformer Unearthed low-power voltage transformer Standard values of rated auxiliary power supply voltage Standard reference values of other influencing parameters Standard reference range of frequency Standard reference range of auxiliary power supply voltage Standard reference range of burden Standard reference range of temperature 0 7. DESIGN FEATURES OF THE LOW-POWER VOLTAGE TRANSFORMER VS- 7. Insulation requirements for primary voltage 7.. Rated insulation levels for primary terminals 7..2 Power-frequency withstand voltage 7..3 Lightning impulse capability 7..4 Power-frequency withstand voltage for earthed terminal 7..5 Partial discharges 7..6 Chopped lightning impulse 7..7 Capacitance and dielectric dissipation factor

3 3/9 7.2 Insulation requirements for low-voltage components 7.2. Power-frequency voltage withstand capability Impulse voltage withstand capability 7.3 Short-circuit withstand capability Limits of temperature rise General requirements Radio interference voltage requirements Transmitted overvoltage requirements Electromagnetic compatibility requirements Emission requirements Immunity requirements Reliability Abnormal conditions withstand capability Abnormal condition signalling 3 7. Mechanical requirements Earthing terminals Earthing of the primary voltage and primary converter Earthing of the secondary converter 4 8. CLASSIFICATION OF TESTS 4 8. Type tests Routine tests Special tests Type tests for indoor post insulator installation Sample tests for indoor post insulator installation Routine test indoor installation 5 9. MARKINGS 6 9. Rating plate markings Terminals markings Connector type RJ Record of Insulator Maintenance requirement 7 0. ACCURACY FOR SINGLE-PHASE ALTEA VS- ELECTRONIC MEASURING VOLTAGE TRANSFORMER 7. ADDITIONAL REQUIREMENTS FOR SINGLE-PHASE ELECTRONIC PROTECTIVE VOLTAGE TRANSFORMERS 8. Standard accuracy classes for electronic protective voltage transformers 8.2 Transient performance requirements 8.2. Primary short circuit 8.3 Opening on a line 8.4 Reclosing on a line with trapped charges 8

4 4/9 SCOPE OF THE DOCUMENT The scope of the present document is the definition of technical characteristics of the Low-Power Voltage Transformer for indoor use Altea VS- in accordance with reference documents listed in Chapter 3.. VS- DESCRIPTION The device under specification (Fig.) is a MV low-power voltage transformer. It has the main electrical and mechanical characteristics listed in the table below. * marks the characteristics that can be set to different values upon request. Rated insulation level 24/50/25 kv Rated primary voltage, Upn * 20/ 3 kv Maximum voltage, Um 24 kv Rated secondary voltage, Usn * V Rated voltage factor, Ku,9 for 8h Nominal frequency 50 / 60 Hz Nominal transformation ratio, Kn * 20/ 3 kv / V Accuracy class * 3P for protection 0.5 for measurements Accuracy on Harmonics Special Quality metering Auxiliary Supply voltage ±2 Vdc Max. Auxiliary Supply current 5 ma Bandwidth (-3 db) 00 khz Creepage 375 mm Primary terminal capacity pf Weight,6 kg Applicable Standards IEC , IEC 60660

5 5/9 Fig. Low-power voltage transformer VS-

6 6/9 3. REFERENCE DOCUMENTS The following reference documents were considered for the definition of Altea VS- operational characteristics:. IEC (999-2) "Instrument transformers - Part 7: Electronic voltage transformers"; 2. IEC 60660: Insulators - Tests on Indoor Post Insulators of Organic Material for Systems with Nominal Voltages Greater Than 000 V up to but Not Including 300 kv; 3. IEC (2002) "Instrument transformers - Part 8: Electronic current transformers"; 4. IEC (200) High voltage test techniques Part : General definitions and test requirements ; 5. IEC 6085 (986) Guide for the selection of insulator in respect of polluted conditions 6. IEC (996) Insulation co-ordination - Part 2: Application guide 4. OPERATIONAL CHARACTERISTICS of ALTEA VS- According to [], the operational characteristics are collected into six main sessions: 5. Service conditions; 6. Rating, 7. Design features; 8. Test performed; 9. Markings; 0. Accuracy for single-phase Altea VS- electronic measuring voltage transformer;. Additional requirements for single-phase Altea VS- electronic protective voltage transformer. 5. SERVICE CONDITIONS OF THE ALTEA VS- According to [ and 2] the low-power voltage transformer Altea VS- is suitable for both measuring and protection purposes. 5. Service conditions 5.. Ambient Air Temperature The ambient air temperature range is the standard one for indoor applications: [-5; + 40] C.

7 7/ Altitude For installations at an altitude higher than 000 m, the arcing distance under the standardized reference atmospheric conditions is determined by multiplying the withstand voltages required at the service location by a factor k in accordance with Figure 3 of [] Vibrations on earth tremors Typical vibrations to the low-power voltage transformer due to external causes or earth tremors do not affect the operation of VS Service conditions for indoor ALTEA VS- Altea VS- is compliant with the requirements of [, 4..4] regarding the service conditions for indoor use: Table 5. Solar radiation Humidity and water vapour Negligible ) the average value of the relative humidity, measured during a period of 24 h does not exceed 95 %; 2) the average value of the relative humidity for a period of one month does not exceed 90 %; 3) the average value of the water vapour pressure for a period of 24 h does not exceed 2,2 kpa; 4) the average value of the water vapour pressure for a period of one month does not exceed,8 kpa. 5.2 Earthing system [, 4.3] The Altea VS- is an earthed low-power voltage transformer. The output voltage of the Altea VS- is representative of the phase to ground primary voltage. 5.3 Material The Altea VS- is epoxy resin material named EA-2470/NA whose features are reported in Table 5.2.

8 8/9 Table 5.2

9 9/9 VALUE TEST SPECIFICATION UNIT indicative nominal ** Tollerance Note Specific heat Thermal conductivity Coefficient of linear thermal expansion Index of temperature ( 50% flexural resistance h) ASTM D-2303 DIN 5362 UNI 4289 j kg * C W 0,6 0,9 m * C ASTM D-696 UNI 606 C- 4 * 0-5 IEC 6026 DIN Glass transition temperature Heat deformation resistance according to Martens IEC C DIN UNI 428 Flammability temperature DIN 5584 > 250 Glow resistance of sample finished piece ASTM igniz. D-229 Met. II spegn. IEC Optical density max ASTM E 662 s 00 positive result Acid alogenidric gaseous CEI Parte I mg/g absent index of tosicity CEI Parte II Action resistance of micro-organisms ASTM G2-G22 good Resistance of oils, solvents, detergents, hot and cold water good

10 0/9 5.4 Safety The Low-power voltage transformer Altea VS- has an intrinsically safe failure mode. In case of failure, avoids explosive shattering of the housing. The Supplier is able to provide sufficient service experience evidence to support a particular design is not associated with brittle fracture problems. 6. RATING OF THE LOW-POWER VOLTAGE TRANSFORMER VS- 6. Standard values of rated voltages [, 5.] 6.. Rated primary voltage The Altea-VS- operates with rated primary voltage values from 6 to 20/ 3 kv Rated secondary voltage The Altea-VS- rated output voltage is V. 6.2 Standard values of rated voltage factor ku [, 5.3] 6.2. Earthed low-power voltage transformers The voltage factor of the Altea VS- is, Unearthed low-power voltage transformers for Altea VS Standard values of rated auxiliary power supply voltage [, 5.4] Power supply voltage for the Altea VS- is 2 Vdc. 6.4 Standard reference values of other influencing parameters [, 5.5] 6.4. Standard reference range of frequency The accuracy class of the Altea VS- is assured for frequencies ranging from 99 % to 0 % of the rated frequency for measurements purposes and from 96 % to 02 % for protection purposes Standard reference range of auxiliary power supply voltage The accuracy class of the Altea VS- is assured for auxiliary power supply ranging from 90 % to 0 % of the rated auxiliary power supply voltage.

11 / Standard reference range of burden The accuracy class of the Altea VS- is assured for load impedances above 00 k Standard reference range of temperature The standard reference range of ambient air temperature is from -5 to +40 C. 7. DESIGN FEATURES OF THE LOW-POWER VOLTAGE TRANSFORMER VS- 7. Insulation requirements for primary voltage [, 6] 7.. Rated insulation levels for primary terminals The rated insulation level of the primary voltage of VS- is 24 kv Power-frequency withstand voltage Power-frequency withstand voltage is 50 kv Lightning impulse capability The lighting impulse capability is 25 kv Power-frequency withstand voltage for earthed terminal The terminal of the primary voltage sensor intended to be earthed must, when insulated from the case or frame, be capable of withstanding a rated power-frequency short-duration withstand voltage of 3 kv (r.m.s.) for min. for Altea VS- since one of the input terminals is connected to ground and to the case Partial discharges The Altea VS- features partial discharge levels are below 50 pc at 28,8 kv (equal to,2 24) and below 20 pc at 6,6 kv (equal to,2 24/ 3). Partial Discharge extinction level is 5,2 kv (equal to, 24/ 3) Chopped lightning impulse If additionally specified, the primary voltage terminals shall also be capable of withstanding a chopped lightning-impulse voltage which has a peak value of 5 % of the full lightning-impulse voltage. for Altea VS-.

12 2/ Capacitance and dielectric dissipation factor These requirements apply only to low-power voltage transformers with liquid-immersed primary voltage sensor insulation having Um 72,5 kv. for Altea VS Insulation requirements for low-voltage components [, 6.2] Available upon special customer request. This insulation shall meet the following requirements: 7.2. Power-frequency voltage withstand capability Withstand voltage level: 2,8 kv r.m.s Impulse voltage withstand capability Withstand voltage level: 5 kv. 7.3 Short-circuit withstand capability [, 6.3] Altea VS- is capable of withstanding short circuit between secondary voltage terminals for the duration of 60 s, when energized at rated voltage. 7.4 Limits of temperature rise [, 6.4] 7.4. General requirements Altea VS- withstands the thermal effects caused by the following conditions: maximum specified ambient temperature (+ 40 C); rated frequency (50/60 Hz);,2 times the rated primary voltage [,2 20/ 3 = 3,85 kv]; the combination of auxiliary power supply voltage and secondary burden which causes the maximum internal power dissipation of the secondary converter (±2 V power supply and 5 k minimum load impedance value). 7.5 Radio interference voltage requirements [6.5] The purpose of the radio interference voltage test is to verify the emission of corona discharges created by the low-power voltage transformer. The main cause of corona discharges are high-voltage parts and partial discharges at the surface of the insulator housing. This test is relevant for low-power voltage transformers having Um 23 kv. for Altea VS-.

13 3/9 7.6 Transmitted overvoltage requirements [, 6.6] Alta VS- is protected against the emissions of overvoltages transmitted from the primary to the secondary output or to the power supply. 7.7 Electromagnetic compatibility requirements [, 6.7] Altea VS- is in compliance with all the requirements reported in [], both concerning the immunity and emissions. In particular the following tests have been carried out and passed Emission requirements Immunity requirements - Harmonic and interharmonic disturbance - Slow voltage variation - Voltage dips and short interruptions - Surge immunity - Electrical fast transient / burst - Oscillatory wave immunity - Electrostatic discharge - Power frequency magnetic field immunity - Pulse magnetic field immunity - Damped oscillatory magnetic field immunity - Radiated radio-frequency electromagnetic field immunity. 7.8 Reliability [, 6.8] The estimated MTTF of the Altea VS- is h. 7.9 Abnormal conditions withstand capability [, 6.9] Depending on the technology used, the short-circuit withstand capability and overheating withstand capability only apply to the secondary converter. for Altea VS-.

14 4/9 7.0 Abnormal condition signalling [, 6.0] Altea VS- is designed in order to avoid spurious tripping of protective relays in presence of impulse voltages. 7. Mechanical requirements [, 6.] These requirements apply only to low-power voltage transformers which have a highest voltage for equipment of 72,5 kv and above. for Altea VS Earthing terminals [, 6.2] 7.2. Earthing of the primary voltage and primary converter Altea VS- is earthed thought the two clamping screws with diameter of 0 mm (see Fig. ) Earthing of the secondary converter for Altea VS-. 8. CLASSIFICATION OF TESTS In the following the Type tests and Routine tests performed for Altea VS- are listed. 8. Type tests [, 7.] a) lightning impulse test [, 8..2]; b) switching impulse test [, 8..3]; c) wet test for outdoor type low-power voltage transformers [, 8.2]; for Altea VS-24-S. d) tests for accuracy [, 8.3]; e) abnormal conditions withstand capability test [, 8.4]; for Altea VS-24-S. f) radio interference voltage test [, 8.5]; for Altea VS-24-S. g) transmitted overvoltage test [, 8.6]; for Altea VS-24-S. h) electromagnetic compatibility tests: emission [, 8.7.] i) electromagnetic compatibility tests: immunity [, 8.7.2] j) impulse voltage withstand test for low-voltage components [, 8.8] k) transient performance test [, 8.9]: - primary short-circuit [, 8.9.];

15 5/9 - reclosing on a line with trapped charges [, 8.9.2]; for Altea VS Routine tests [, 7.2] a) verification of terminal markings [, 9.] b) power-frequency withstand tests on primary voltage terminals [, 9.2] c) partial discharge measurement [, 9.2.4]; d) power-frequency voltage withstand test for low-voltage components [, 9.3] Only on insulators with sensor equipped with galvanic insulation. e) tests for accuracy [, 9.4] 8.3 Special tests [, 7.3] * a) chopped lightning-impulse test on primary voltage terminals [, 0.]; b) measurement of capacitance and dielectric dissipation factor [, 0.2]; c) mechanical strength tests [, 0.3]; * To be performed on client request. In addition, for post insulators of organic material for indoor service in electrical installations or equipment operating in air at atmospheric pressure on alternating current with a nominal voltage greater than 000 V up to, but lower than 300 kv, test foreseen by the standard [2] are applied. 8.4 Type tests for indoor post insulator installation [2, 3] a) water absorption test [2, 3.0]; b) flammability test [2, 3.2]; c) ageing and humidity test [2, 3.]. d) test for mechanical bending strength as a function of temperature [2, 3.9]; e) dry lightning impulse withstand voltage test [2, 3.3]; (covered by test a) of Type tests) f) dry power-frequency withstand voltage test [2, 3.4]; g) lightning impulse puncture test [2, 3.6]; h) temperature cycle test [2, 3.3]; i) partial discharge extinction voltage test [2, 3.5]; j) test for deflection under load at normal ambient temperature conditions [2, 3.8]; k) mechanical failing load test (bending test, tensile test, torsion test, compres. test) [2, 3.7].

16 6/9 8.5 Sample tests for indoor post insulator installation [2, 4] The samples shall then be subjected to the following tests in the order given: a) verification of dimensions [2, see 4.2]; b) water absorption test for materials other than cast epoxy resin or PUR resin only [2, 3.0]; c) partial discharge extinction voltage test [2, 3.5]; (covered by test c) of Routine tests) d) test for deflection under load at normal ambient temperature conditions [2, 3.8] *; e) test for mechanical strength at normal ambient temperature conditions [2, 3.7] *. * To be performed on client request. 8.6 Routine tests for indoor installation [2, 5] a) visual examination [2, 5.2]; b) mechanical routine test for insulators of design category A; for insulators intended to be used at rated voltage 72,5 kv and above only [2, 5.3]; for Altea VS-. c) electrical routine test and partial discharge measurement for post insulators of design category B [2, 5.4]; (covered by test c) of Routine tests) 9. MARKINGS [, 2,.5] 9. Rating plate markings The rating plate of the electronic device is reported in the below figure. Designation: Electronic Voltage Transformer (EVT) Type: Weight: Serial/year: Ref. Std.: VS-.6 kg Electrical Characteristics Auxiliary Power Supply Rated Insulation Level = 24/50/25 kv Uar = ±2 V DC

17 7/9 fr = 50/60 Hz Iar = 0 ma Ia max = 5 ma EVT Characteristics Upr/Usr = 20/ 3kV / V φor = 0 º Rbr = 00 kω ku =,9 / 8h Class Terminal markings 9.2. Connector type RJ45 GND 2 GND 3 GND 4 GND 5 V out 6 V out V cc 8 - V SS 9.3 Record of Insul ator Altea BV maintains records of all produced insulators in accordance with this standard for a minimum of 0 years. These records contains the following information: type reference number; year of manufacture; type tests, date and results; sample tests, date and results; routine tests, date and results. 9.4 Maintenance requirement Altea Low-power voltage transformer Altea VS-I is a disposable device. No sub-parts can be replaced. 0. ACCURACY FOR SINGLE-PHASE ALTEA VS- ELECTRONIC MEASURING VOLTAGE TRANSFORMER [, 2]

18 8/9 The low-power voltage transformer Altea VS- is in the Accuracy class 3P for protection and 0,5 for measurement, in the range of temperature ranging from - 25 to + 65 C.. ADDITIONAL REQUIREMENTS FOR SINGLE-PHASE ELECTRONIC PROTECTIVE VOLTAGE TRANSFORMERS [, 3]. Standard accuracy classes for electronic protective voltage transformers Standard accuracy class for Altea VS- is 3P..2 Transient performance requirements.3. Primary short circuit Following a short circuit of the supply between the high-voltage terminal and the low-voltage terminal connected to earth, the secondary output voltage of Altea VS- will decay, within one cycle of rated frequency, to a value of less than 0 % of the peak value before short circuit..3 Opening on a line When opening a line results in a trapped charge, the secondary voltage component Us dc(t) shall decay to zero in order to prevent saturation of input transformers of the connected equipments. This time constant must be declared by the manufacturer. for Altea VS-..4 Reclosing on a line with trapped charges for Altea VS-. END OF DOCUMENT

19 9/9

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER Customer : REV. 0 Page 1/16 Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INRUMENTRANSFORMER CVS - 24 - G - Revision Prepared Description Checked by Rev. Date by 0 13/06/16 First issue E.

More information

Electronic Combined Current and Voltage Transformer Altea CVS-24-O Technical Specifications

Electronic Combined Current and Voltage Transformer Altea CVS-24-O Technical Specifications /7 Electronic Combined Current and Voltage Transformer Altea CVS-24- Technical Specifications Rev. Date Revision Description Prepared by Checked by Approved by 0 26/06/4 First Issue E. Scala L. Peretto

More information

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide Relion 605 series Relion 605 series Self-Powered Feeder Protection Product Guide Contents 1 Description...3 2 Protection functions...3 3 Application...4 4 Self-supervision...4 5 Inputs and outputs...4

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

08/07/2015

08/07/2015 17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external

More information

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s

Type 297, High-Voltage Mica Capacitors Corona-free Mica Coupling Capacitors for Medium-Voltage PDA s Designed for Partial Discharge Analyzers (PDA s) monitoring rotating machinery or other medium-voltage equipment from 1 to 35 kvac RMS at power-line frequencies of 10 Hz to 1 khz, Mica Capacitor Type 297

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTENATIONAL STANDAD IEC 60044-2 Edition 1.2 2003-02 Edition 1:1997 consolidated with amendments 1:2000 and 2:2002 Instrument transformers Part 2: Inductive voltage transformers This English-language version

More information

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds

More information

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds

More information

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB STANDARD 022 : 1994 Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEYLON ELECTRICITY BOARD SRI LANKA Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB Standard 022 : 1994

More information

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS AS 60044.1 2007 AS 60044.1 2007 Australian Standard Instrument transformers Part 1: Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD) This Australian Standard was prepared by Committee EL-013, Measurement

More information

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi TS ii ortable Tourniquet System Guidance and manufacturer s declaration electromagnetic emissions The TS ii ortable Tourniquet

More information

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring The first Real-Time Protection and Automation platform that can be adapted to a wide variety of applications. While

More information

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 4.0 Sectionalizer Construction... 4 5.0 Mechanism... 6 6.0 Solid Dielectric

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

C series Product brief

C series Product brief Product brief Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 0 ctive energy Low power consumption larm function Pulse output Installation Small size - 1

More information

9 Specifications. Specifications NOMINAL CHARACTERISTICS

9 Specifications. Specifications NOMINAL CHARACTERISTICS 9 Specifications Specifications NOMINAL CHARACTERISTICS WARRANTED CHARACTERISTICS Nominal characteristics describe parameters and attributes that are guaranteed by design, but do not have associated tolerances.

More information

08/07/2015

08/07/2015 17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER Analysis of Major Changes to Arrester Standards IEC 60099-4 STEVE BREWER Analysis of Major Changes to Arrester Standard IEC 60099-4 Steve Brewer- Senior Product Manager - HPS Arrester Business Unit Agenda

More information

SAMSUNG ELECTRO-MECHANICS CO., LTD

SAMSUNG ELECTRO-MECHANICS CO., LTD Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OVP/OTP/SCP ㅡ 0-10V Dimming Control ㅡ IP67 ㅡ

More information

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC standards. Presented by: Karim Loukil & Kaïs Siala Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards

More information

High Performance Current Transducer ITL 900-T = A

High Performance Current Transducer ITL 900-T = A High Performance Current Transducer ITL 900-T For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I PM = 0... 900 A Electrical

More information

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS 006: 2008 CEB SPECIFICATION COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS CEYLON ELECTRICITY BOARD SRI LANKA Specification for COMBINED METERING TRANSFORMERS (OUTDOOR TYPE) FOR

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel

More information

High precision measurement system for current and voltage IHC-A/B-RM01/03

High precision measurement system for current and voltage IHC-A/B-RM01/03 Measurement Offset-free and low-noise 16 bit data acquisition system ISA-ASIC Internal sample rate 3,500 Hz Communication Standard RS232- or RS485 interface Advantages Direct measurement on the bus bar

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

Analog signal converters CC-E I/I

Analog signal converters CC-E I/I 2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage

More information

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter Features Regulated Converter Unique, patent-pending design Isolated power supply with integrated mains filter Packaged inside of line filter case Safe, touchable DC outputs Easy installation Worldwide

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

High-Voltage Test Techniques

High-Voltage Test Techniques High-Voltage Test Techniques Dieter Kind Kurt Feser 2nd Revised and Enlarged Edition With 211 Figures and 12 Laboratory Experiments Translated from the German by Y. Narayana Rao Professor of Electrical

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter Features Regulated Converters Description Compact low profile AC-DC power supply mw no load power consumption Class II power supply with kvac isolation Universal input voltage range (~VAC) Low output ripple/noise

More information

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component

More information

Ohmic Voltage Sensor GSER 16

Ohmic Voltage Sensor GSER 16 Ohmic Voltage Sensor GSER 16 including Isolating Amplifier EGIW 804 AV Medium Voltage Applications Direct, Alternating and Mixed Voltages Wide Frequency Range Electrical Isolation Ohmic Voltage Sensor

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual REK 50 protection of a synchronous machine User s Manual REK 50 X 0 9 8 7 6 5 4 0 V 00 V 0 V 5 6 7 Ordering No: REK 50-AA Uau = 00/0 Vac Un = 48 V Serial No: fn = 50/60 Hz Uec = ma 600 Vdc MRS 75587-MUM

More information

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis

More information

Liquid level monitoring relay CM-ENS.2x

Liquid level monitoring relay CM-ENS.2x Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry

More information

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Christian Suttner*, Stefan Tenbohlen Institute of Power Transmission and High Voltage Technology (IEH), University of

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Modem 9600 baud 500FSD11 EDS500 series - FSK modems Data sheet Modem 9600 baud 500FSD11 EDS500 series - FSK modems Voice frequency telegraphy device (VFT) Transparent up to 9600 baud Can be connected to 23WT24 DIN rail mounted 24...60 V DC supply voltage

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing

More information

NXCT 345 kv Test Performance Record For LAPEM

NXCT 345 kv Test Performance Record For LAPEM 2005 NxtPhase T&D Corporation 2635 Lillooet St. Vancouver, Canada, V5M 4P7 www.nxtphase.com Tel: 604 215 9822 Fax: 604 215 9833 NXCT 345 kv Test Performance Record For LAPEM Information in this document

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks. 2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Test Specification for Type Approval

Test Specification for Type Approval A2 (1991) (Rev.1 1993) (Rev.2 1997) (Rev. 2.1 July 1999) (Rev.3 May 2001) (Corr.1 July 2003) (Rev.4 May 2004) (Rev.5 Dec 2006) (Rev.6 Oct 2014) Test Specification for Type Approval.1 General This Test

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

ELCAR T ART. 3/3406 3/3620 PAGINA 1 DI 7. servizio automatico documentazione tecnica T T W H

ELCAR T ART. 3/3406 3/3620 PAGINA 1 DI 7. servizio automatico documentazione tecnica T T W H ART. 3/3406 3/3620 PAGINA DI 7 CUSTOMER : CUSTOMER'S REFERENCE : 3/34 3/35 3/36 Series DESCRIPTIONS : SHENGXIN TY : METALLIZED POLYESTER FILM CAPACITOR-BOX series Fig. w T T W H.5max P 20min H S L0.5max

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital

More information

Roadmap For Power Quality Standards Development

Roadmap For Power Quality Standards Development Roadmap For Power Quality Standards Development IEEE Power Quality Standards Coordinating Committee Authors: David B. Vannoy, P.E., Chair Mark F. McGranghan, Vice Chair S. Mark Halpin, Vice Chair D. Daniel

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Overcurrent Protection / 7SJ46 SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Function overview Fig. /11 Description The SIPROTEC easy 7SJ46 is a numerical overcurrent protection relay which

More information

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation Portable Description Features Measures all of the main electrical parameters of an electricity network Measurement in true root mean square Built-in energy meter With 4 voltage channels and 4 current channels

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

DATA SHEET MKP 435 X2

DATA SHEET MKP 435 X2 DATA SHEET Interference suppression film capacitors, NEW File under BCcomponents, BC05 2001 Jun 22 MKP RADIAL POTTED TYPE PITCH 15/22.5/27.5 mm 296x12(full_width) CBB112 Fig.1 Simplified outlines. FEATURES

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60044-2 Edition 1.2 2003-02 Edition 1:1997 consolidated with amendments 1:2000 and 2:2002 Instrument transformers Part 2: Inductive voltage transformers IEC 2003 Copyright -

More information

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H018F1 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component

More information

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load Features Regulated Converter Description 4mW max. no load power consumption High efficiency up to 76% Isolated output 3kVAC / 1 min SCP, OVP protection Wide operating temperature range: -4 C to +85 C Universal

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application

More information

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter Features Switching Regulator Description Efficiency up to 96%, no need for heatsinks 2A continuous output current Vin up to 32V Vout: 1.2V - 15V Wide operating temperature - C to +7 C at full load Continuous

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

Three-phase monitoring relay CM-PBE

Three-phase monitoring relay CM-PBE Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS

CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS 1. Introduction 2. Classification of High Voltage Tests 3. Test Voltages 4. High Voltage Testing of Electrical Apparatus 1. INTRODUCTION Purpose

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Custom "Compact" range with display CD20 Custom Part number

Custom Compact range with display CD20 Custom Part number Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable

More information

Low voltage products in high altitudes

Low voltage products in high altitudes WHITE PAPER Low voltage products in high altitudes Information and technical guidance for applications above 2000 m sea level This white paper provides information including technical guidance for high

More information

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter Features Regulated Converters 5W Class II Power Supply in Compact 1 x 1 Package (High Power Density) Internal EMC Class B Filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical Protection

More information

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1 Post: Last Amended on - Page 1 of 6 LOCATION 1 I. TRANSFORMERS AND REACTORS 1. 500 MVA, 765 kv 500 MVA, 400 kv Ratio & Polarity Check Magnetic Balance & Magnetizing Current Measurement at Low Voltage Vector

More information

VI 3 - i TABLE OF CONTENTS

VI 3 - i TABLE OF CONTENTS VI 3 - i TABLE OF CONTENTS 3 PROJECT SPECIFIC DATA... 1 3.1 DEFINITIONS... 1 3.1.1 Design Data, High and Medium Voltage... 1 3.1.2 Design Data, Low Voltage Equipment... 2 3.1.3 Phase Relationship... 3

More information

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions

More information

Resistive capacitive voltage divider

Resistive capacitive voltage divider Resistive capacitive voltage divider Outdoor operation Oil insulated ROF 72 550 kv General description Resistive capacitive voltage dividers type ROF (RC divider) are used in high voltage networks within

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TIB Series, 80 480 W Slim profile, reduced module width High Power Factor up to 99% High efficiency up to 94% True back power immunity Low heat dissipation 150% peak current Automatic

More information

SPAE 010, 011 High Impedance Protection Relay

SPAE 010, 011 High Impedance Protection Relay SPAE 010, 011 High Impedance Protection Relay User s manual and Technical description f n = 50/60 Hz U n = 50 / 100 / 200 V 2 5 U REF > SPAE 010 0.8 U aux 0.6 1.0 RESET OK x 80... 265 V ~ _ 0.4 U > U n

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter Features Regulated Converter Description 5W Class II power supply in compact 1 x 1 Package (high power density) Internal EMC class B filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical

More information

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter Features Regulated Converter Description mw max. no load power consumption High efficiency up to 79% Isolated Output 3.75kVAC / 1 minute SCP, OVP protection Wide operating temperature range: -4 C to +

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

02/11/2015

02/11/2015 35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM/SP33 series N = 8, 15, 25 A Ref: HO 8-NSM/SP33, HO 15-NSM/SP33, HO 25-NSM/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the

More information

BENNING. CM7 Electrical Tester. Service Information

BENNING. CM7 Electrical Tester. Service Information BENNING CM7 Electrical Tester Service Information TABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specification

More information

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter Features Regulated Converter Description Wide input range 85-5VAC Standby mode optimized (eco design Lot 6) High efficiency over the entire load range Operating temperature range: - C to + C Overvoltage

More information

D C 01/2019 3

D C 01/2019 3 D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while

More information