1 CE Marking For the EverPro Technologies Company Ltd. Model: EPU3HC-NNMMXYYYL WLL Report#14WB E Rev. 0 Prepared for: EverPro Technologies Company Ltd. 4# Guanshan Er Road, Wuhan P,R, China Prepared by: WASHINGTON TECHNOLOGY INTERNATIONAL LIMITED This report applies only to the sample evaluated prior to the preparation date stated above. This report must be copied in its entirety, including all technical documents Certificates and reports shall not be reproduced except in full.

2 CE Marking For the EverPro Technologies Company Ltd. Model: EPU3HC-NNMMXYYYL WLL Report#14WB E Rev. 0 Prepared by: Henry guo Reviewed by: Steven yang WLL Report #14WB E Rev. 0 - ii Washington Laboratories, Ltd.

3 Abstract This report has been prepared on behalf of EverPro Technologies Company Ltd. to document the findings of the emissions and immunity testing performed on the EverPro Technologies Company Ltd.. The purpose of this testing is to determine compliance with emissions and immunity requirements set forth by the European Community under the requirements of the EMC Directive (2004/108/EC). This test report supports the EverPro Technologies Company Ltd. Declaration of Conformity for compliance with applicable specifications under the EMC Directive. The requirements of the EMC Directive specify compliance with emissions and immunity standards. This report is based on testing methods and levels called out in: EN 55022:2010+AC:2011: Limits and methods of measurement of radio Emission characteristics of information technology equipment EN :2010: Information technology equipment-immunity characteristics limits and methods of measurement EN :2006+A1:2009+A2:2009: Electromagnetic compatibility(emc)-part 3 : Limits- Section 2 : Limits for harmonic current emissions EN :2013: Electromagnetic compatibility(emc)-part 3 :Limits Section 3 : Limits of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated IEC :2008, Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test IEC :2010, Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test IEC :2012, Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques Electrical fast transient/burst immunity test IEC :2005, Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test IEC :2013, Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields IEC :2009, Electromagnetic compatibility (EMC) Part 4-8: Testing and measurement techniques Power frequency magnetic field IEC :2004, Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement techniques Voltage dips, short interruptions and voltage variations immunity tests WLL Report #14WB E Rev. 0 - iii Washington Laboratories, Ltd.

4 The affixation of the "CE" marking is contingent on the product's compliance with all applicable "New Approach Directives. The conduct of this test supports the emissions and immunity requirements specified under the EMC Directive. Other directives or standards may apply (Low Voltage Directive, for example) for which a separate certification effort may be required. Other national standards may apply on a country-by-country basis for which a separate approval may be required. Testing was performed at Audix Technology (Shenzhen) Co., Ltd. The CNAS Registration No.: L4117 The EverPro Technologies Company Ltd. complied with the EMC requirements of and EN 55022, EN Revision History Reason Date Rev 0 Initial Release WLL Report #14WB E Rev. 0 - iv Washington Laboratories, Ltd.

5 Table of Contents Abstract... ii 1 Introduction Compliance Statement Test Scope Summary Contract Information Test and Support Personnel Equipment Under Test EUT Identification Test Configuration EUT Description Equipment Configuration Interface Cables Support Equipment EUT Modifications Testing Algorithm Test Location Test Deviations and Sequence Deviations to the Standard Performance Criteria Test Result Conducted Emissions Radiated Emissions HARMONIC CURRENT TEST VOLTAGE FLUCTUATIONS & FLICKER Electrostatic Discharge Radiated RF Susceptibility Electrical Fast Transient/Burst Voltage Surge Conducted RF Susceptibility Magnetic field immunity test VOLTAGE DIPS AND INTERRUPTIONS TEST Attachment (EUT Photograph) Appendix WLL Report #14WB E Rev. 0 - v Washington Laboratories, Ltd.

6 List of Tables Table 1: Overview of, Equipment Under Test... 4 Table 2: Equipment Configuration... 7 Table 3: Interface Cables... 7 Table 4: Conducted Emission Test Data Table 5: Radiated Emission Test Data AC Power Table 6: Harmonic Test Data Table 7: Flicker Test Data Table 8: ESD Test Results Table 9: Radiated RF Susceptibility Test Results Table 10: Electrical Fast Transient/Burst Test Results Table 11: Voltage Surge Test Results Table 12: Conducted RF Susceptibility Test Results Table 13: Magnetic field immunity Test Results Table 14: Voltage Dips/Interrupts Test Results Table 15: Expanded Uncertainty List List of Figures Figure 1: Test Configuration... 4 List of Photographs Photograph 1: Conducted Emission Test Configuration, Front Photograph 2: Conducted Emission Test Configuration, Side Photograph 3: Radiated Emission Test Configuration, Front Photograph 4: Radiated Emission Test Configuration, Back Photograph 5: Radiated Emission Test Configuration, (Above 1GHz) Front Photograph 6: Harmonics Test Configuration Photograph 7: Voltage Fluctuation and Flick Test Configuration Photograph 8: ESD Test Configuration, V Plate Photograph 9: ESD Test Configuration, H Plate Photograph 10: Radiated RF Susceptibility Test Configuration Photograph 11: Electrical Fast Transient/Burst Test Configuration Mains /Port Photograph 12: Electrical Fast Transient/Burst Test Configuration Telecommunication /Port Photograph 13: Voltage Surge Immunity Test Configuration Mains /Telecommunication Port Photograph 14: Conducted RF Susceptibility Test Configuration Mains / Port Photograph 15: Conducted RF Susceptibility Test Configuration Telecommunication / Port Photograph 16: Magnetic field immunity Test Configuration Mains /Port Photograph 17: Voltage Dips/Interrupts Test Configuration WLL Report #14WB E Rev. 0 - vi Washington Laboratories, Ltd.

7 1 Introduction Washington Technology International Limited was contracted by EverPro Technologies Company Ltd. to perform testing on the. This document describes the test setups, test methods, required test equipment, and the test limit criteria used to perform compliance testing of the EverPro Technologies Company Ltd. 1.1 Compliance Statement After the modification listed in Section 2.7 were installed: The EverPro Technologies Company Ltd. complied with the EMC emission requirements of EN 55022, EN Tests for radiated and conducted emissions were performed. Tests were performed according to: EN 55022:2010+AC:2011, Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement EN :2010: Information technology equipment-immunity characteristics limits and methods of measurement EN :2006+A1:2009+A2:2009, Electromagnetic compatibility (EMC) Part 3-2: Testing and measurement techniques Harmonic immunity test EN :2013, Electromagnetic compatibility (EMC) Part 3-3: Testing and measurement techniques Flicker immunity test IEC :2008, Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test IEC :2010, Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test IEC :2012, Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques Electrical fast transient/burst immunity test IEC :2005, Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test IEC :2013, Electromagnetic compatibility (EMC) Part 4-6: Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields IEC :2009, Electromagnetic compatibility (EMC) Part 4-8: Testing and measurement techniques Power frequency magnetic field IEC :2004, Electromagnetic compatibility (EMC) Part 4-11: Testing and measurement techniques Voltage dips, short interruptions and voltage variations immunity tests Report #14WB E Rev. 0 - Page 1 of Washington Laboratories, Ltd.

8 1.2 Test Scope Summary Test Specific Description Date Completed Result EN 55022:2010+ AC:2011 CISPR 22:2008 EN 55022:2010+ AC:2011 CISPR 22:2008 EN 55022:2010+ AC:2011 CISPR 22:2008 EN :2006+A1:2009+A2: 2009 EN :2013 Conducted Emissions at the Mains Port Conducted Emission at telecommunication port Radiated Emissions Harmonic Current Emissions Voltage Fluctuation & Flicker Modifications Installed (Y/N) Dec.23, 2014 Complied N N/A N/A N Dec.13, 2014-Jan.04, 2015 Complied Jan.06, 2015 Complied N Jan.06, 2015 Complied N N EN IEC Electrostatic Discharge Dec.11, 2014 Complied N EN IEC EN IEC EN IEC EN IEC EN IEC EN IEC Radiated RF Susceptibility Electrical Fast Transient/Burst Dec.13, 2014 Dec.11, 2014 Voltage Surge Dec.11, 2014 Radio-frequency, Continuous conducted Emission Power frequency magnetic field Voltage Dips, Interruptions and Variations Dec.13, 2014 Dec.13, 2014 Dec.13, 2014 Complied Complied Complied Complied Complied Complied N N N N N N Report #14WB E Rev. 0 - Page 2 of Washington Laboratories, Ltd.

9 1.3 Contract Information Customer: EverPro Technologies Company Ltd. 4# Guanshan Er Road, Wuhan P,R, China 1.4 Test and Support Personnel Mario Wu Audix Technology (Shenzhen) Co., Ltd. No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, China Test Engineer Report #14WB E Rev. 0 - Page 3 of Washington Laboratories, Ltd.

10 2 Equipment Under Test 2.1 EUT Identification The results obtained relate only to the item(s) tested. Table 1: Overview of, Equipment Under Test Model(s) EUT Specifications: EPU3HC-A1A4K050M 5V DC from USB port Equipment Emissions Class: B Test Date(s): Dec.11, 2014~Jan.06, Test Configuration The EverPro Technologies Company Ltd., Equipment Under Test (EUT), was operated from 5V DC from USB port. The was configured as below: Mouse AC Mains Monitor a Notebook EUT U-Disk Adaptor a: HDMI Cable AC Mains Figure 1: Test Configuration 2.3 EUT Description Product Name: Model No. : EPU3HC-A1A4K050M EUT Rated Voltage: 5V DC from USB port Report #14WB E Rev. 0 - Page 4 of Washington Laboratories, Ltd.

11 Report #14WB E Rev. 0 - Page 5 of Washington Laboratories, Ltd.

12 Report #14WB E Rev. 0 - Page 6 of Washington Laboratories, Ltd.

13 2.4 Equipment Configuration The EUT were set up as outlined in Figure 1. The EUT was comprised of the following equipment. (All Modules, PCBs, etc. listed were considered as part of the EUT, as tested.) Table 2: Equipment Configuration Slot # Name / Description Model Number Part Number Serial Number Revision 1. USB3.0 Hybrid Active Optical Cable EPU3HC-A1A4K050M / / / 2.5 Interface Cables Table 3: Interface Cables Port Connector Cable Shielded Slot # Termination Point Identification Type Length (Y/N) 1. HDMI Cable Shielded; Detachable 1.5m Y AE 2.6 Support Equipment No. Description ACS No. Manufacturer Model Serial Number Approved type 1 U-Disk1 -- Kingston DT100G3/16G U-Disk2(Test For RE) 3 Monitor ACS-EMC-LM10R -- Sandisk SDCZ43/16G DELL U3011t -- FCC DOC 4 Notebook 5 USB Mouse -- LENOVO Lenovo B Power Adapter: Manufacturer: LENOVO, M/N: ADLX90NCT3A Power Cord: Unshielded, Detachable, 1.8m M-U0002- S26381-K426- ACS-EMC-M11R FUJITSU FSC1 V102 USB Cord: shielded, Undetectable, 2.0m FCC ID BSMI ID 2.7 EUT Modifications None. 2.8 Testing Algorithm The was operated continuously by normal operating conditions. During the test, there has a software to control the USB disk continuously communicate with Notebook via the. In immunity testing, if the data transfer from USB disk to Notebook is work normally, then judged as A. If the data Report #14WB E Rev. 0 - Page 7 of Washington Laboratories, Ltd.

14 transfer from USB disk to Notebook disordered but can be recovered without manual involve, then judged as B. If the EUT stop work and need manual involve to restart then judged as C. 2.9 Test Location NAME: Audix Technology (Shenzhen) Co., Ltd. by CNAS. The CNAS Registration No.: L4117. Address: No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, China Report #14WB E Rev. 0 - Page 8 of Washington Laboratories, Ltd.

15 Report #14WB E Rev. 0 - Page 9 of Washington Laboratories, Ltd.

16 3 Test Deviations and Sequence 3.1 Deviations to the Standard There were no deviations to the requirements established in the specification. Report #14WB E Rev. 0 - Page 10 of Washington Laboratories, Ltd.

17 4 Performance Criteria Performance Criterion A B C Description The unit shall continue to operate as intended. No degradation of performance or loss of function is allowed below the performance level specified by the manufacturer. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer then either of these may be derived from the product description and documentation and what the user may reasonably expect from the equipment if used as intended. After the test, the equipment shall continue to operate as intended without user intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below the performance level specified by the manufacturer. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed. However, no change of operating state or stored data is allowed to persist after the test. If the minimum performance level or the permissible performance loss is not specified by the manufacturer then either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls by the user in accordance with the manufacturer s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost. Report #14WB E Rev. 0 - Page 11 of Washington Laboratories, Ltd.

18 5 Test Result 5.1 Conducted Emissions Requirements Test Arrangement: Table Top Compliance Standard: EN Clause 5 Reference Standard: CISPR 22 Clause 5 Compliance Requirement: Class B Frequency Range Tested: 150 khz to 30MHz Frequency 150kHz~500kHz 500kHz~5MHz 5MHz ~30MHz Class A Compliance Limits Quasi-Peak Level db(µv) 66 ~ 56* Average Level db(µv) 56 ~ 46* Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. 1# Shielding Room AUDIX N/A N/A Apr.17,14 1 Year 2. Test Receiver Rohde & Schwarz ESHS /001 Oct.29, 14 1 Year 3. L.I.S.N.#1 Rohde & Schwarz ESH2-Z Oct.29, 14 1 Year 4. L.I.S.N.#3 Kyoritsu KNW-242C Apr.28,14 1 Year 5. Terminator Hubersuhner 50Ω No. 1 Apr.28,14 1 Year 6. Terminator Hubersuhner 50Ω No. 2 Apr.28,14 1 Year 7. RF Cable Hubersuhner RG # Jan.22,14 1 Year 8. Coaxial Switch Anritsu MP59B Apr.28,14 1 Year 9. Pulse Limiter Rohde & Schwarz ESH3-Z Oct.29, 14 1 Year Report #14WB E Rev. 0 - Page 12 of Washington Laboratories, Ltd.

19 5.1.3 Test Setup PC System Receiver EUT Peripheral 80cm 80cm LISN#1 LISN#3 :50Ω Terminator Test Procedure Summary The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT Power connected to the power mains through a line impedance stabilization network (L.I.S.N. 1#). This provided a 50-ohm coupling impedance for the EUT (Please refer to the block diagram of the test setup and photographs). Both sides of power line were checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipments and all of the interface cables were changed according to CISPR 22 on conducted Emission test. The bandwidth of test receiver (R & S ESHS10) is set at 9kHz. The frequency range from 150kHz to 30MHz is checked Conducted Data Reduction and Reporting To convert the EMI Receiver radiated data into a form that can be compared with the limits, it is necessary to account for various calibration factors that are supplied with the antennas and other measurement accessories. These factors are included the antenna factor (AF) and the cable factor (CF). The AF (in db/m) and the CF (in db) is algebraically added to the EMI Receiver Voltage in dbµv to obtain the Radiated Electric Field in dbµv/m. The following data lists the significant emission frequencies, measured levels, correction factors (including cable and antenna correction factors), and the corrected readings against the limits. Explanation of the data is given as follows: Example: EMI Receiver Voltage: VdBµV Antenna Correction Factor: AFdB/m Cable Correction Factor: CFdB Amplifier Gain: AGdB Standard Limits: LdBµV/m Electric Field: EdBµV/m = V dbµv + AFdB/m + CFdB- AGdB Margin: db = LdBµV/m - EdBµV/m Results Summary The EUT complied with the emission requirements throughout the test Test Data Table 4 provides the test results for Conducted emissions. Photograph 1 and 2 show the Conducted emission test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 13 of Washington Laboratories, Ltd.

20 Table 4: Conducted Emission Test Data Report #14WB E Rev. 0 - Page 14 of Washington Laboratories, Ltd.

21 Report #14WB E Rev. 0 - Page 15 of Washington Laboratories, Ltd.

22 Photograph 1: Conducted Emission Test Configuration, Front Photograph 2: Conducted Emission Test Configuration, Side Report #14WB E Rev. 0 - Page 16 of Washington Laboratories, Ltd.

23 5.2 Radiated Emissions Requirements Test Arrangement: Table Top Compliance Standard: EN Clause 5 Reference Standard: CISPR 22 Clause 6 Compliance Requirement: Class B Frequency Range Tested: 30MHz to 1000MHz All emanations from a Class B computing devices or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified below: FREQUENCY DISTANCE FIELD STRENGTHS LIMITS Note: (MHz) Test Equipment (Meters) (dbµv/m) 30 ~ ~ ~ (Peak) 50(Average) 3000~ (Peak) 54(Average) (1) Emission level = Antenna Factor + Cable Loss + Reading Emission level = Antenna Factor -Amp Factor +Cable Loss + Reading (above 1000MHz) (2) The lower limit shall apply at the transition frequencies. (3) Distance refers to the distance in meters between the test instrument antenna and the closed point of any part of the E.U.T. For frequency range 30MHz~1000MHz (In 3m Anechoic Chamber) Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. 3#Chamber AUDIX N/A N/A Nov.23, 14 1 Year 2. EMI Spectrum Agilent E4407B MY Apr. 28,14 1 Year 3. Test Receiver Rohde & Schwarz ESVS /011 Apr. 28,14 1 Year 4. Amplifier HP 8447D 2648A04738 Apr. 28,14 1 Year 5. Bilog Antenna TESEQ CBL6112D Jun. 18, 14 1 Year 6. RF Cable MIYAZAKI CFD400-NL 3# Chamber No.1 Apr. 28,14 1 Year 7. Coaxial Switch Anritsu MP59B Apr. 28,14 1 Year Report #14WB E Rev. 0 - Page 17 of Washington Laboratories, Ltd.

24 For frequency range 1GHz~6GHz (In Anechoic 3m Chamber) Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. 3#Chamber AUDIX N/A N/A Nov.02,14 1 Year 2. Spectrum Analyzer Agilent E4407B MY Apr.28,14 1 Year 3. Horn Antenna ETS Sep.20,14 1 Year 4. Amplifier Agilent 8449B 3008A00863 Apr.28,14 1 Year 5. RF Cable Hubersuhner SUCOFLEX /6 Apr.28,14 1 Year 6. RF Cable Hubersuhner SUCOFLEX /2 Apr.28,14 1 Year Test Setup Setup below 1GHz Setup above 1GHz Report #14WB E Rev. 0 - Page 18 of Washington Laboratories, Ltd.

25 5.2.4 Test Procedure Summary The system was configured at the 3 meter semi-chamber on an 80 cm high 1 X 1.5 m nonconductive table above a ground plane a turntable. During test the system under test was rotated 360 while the antenna was varied in height from 1 to 4 meters. The system under test was examined for emissions with both horizontal and vertical antenna polarizations Measurement Method All emission measurements herein were performed according to CISPR 22. Calibration checks are made periodically to verify proper performance of the measuring instrumentation Radiated Data Reduction and Reporting To convert the EMI Receiver radiated data into a form that can be compared with the limits, it is necessary to account for various calibration factors that are supplied with the antennas and other measurement accessories. These factors are included the antenna factor (AF) and the cable factor (CF). The AF (in db/m) and the CF (in db) is algebraically added to the EMI Receiver Voltage in dbµv to obtain the Radiated Electric Field in dbµv/m. The following data lists the significant emission frequencies, measured levels, correction factors (including cable and antenna correction factors), and the corrected readings against the limits. Explanation of the data is given as follows: Example: EMI Receiver Voltage: VdBµV Antenna Correction Factor: AFdB/m Cable Correction Factor: CFdB Amplifier Gain: AGdB Standard Limits: LdBµV/m Electric Field: EdBµV/m = V dbµv + AFdB/m + CFdB- AGdB Margin: db = LdBµV/m - EdBµV/m Results Summary The EUT complied with the emission requirements throughout the test Test Data Table 5 provides the test results for radiated emissions. Photograph 3,4,5 show the radiated emission test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 19 of Washington Laboratories, Ltd.

26 Table 5: Radiated Emission Test Data AC Power Report #14WB E Rev. 0 - Page 20 of Washington Laboratories, Ltd.

27 Report #14WB E Rev. 0 - Page 21 of Washington Laboratories, Ltd.

28 Report #14WB E Rev. 0 - Page 22 of Washington Laboratories, Ltd.

29 Report #14WB E Rev. 0 - Page 23 of Washington Laboratories, Ltd.

30 Photograph 3: Radiated Emission Test Configuration, Front Photograph 4: Radiated Emission Test Configuration, Back Report #14WB E Rev. 0 - Page 24 of Washington Laboratories, Ltd.

31 Photograph 5: Radiated Emission Test Configuration, (Above 1GHz) Front Report #14WB E Rev. 0 - Page 25 of Washington Laboratories, Ltd.

32 5.3 HARMONIC CURRENT TEST Requirements Test Arrangement: Table Top Reference Standard: EN Clause Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. AC Source California Instruments 5001ix Oct.26, 14 1 Year 2. Power Analyzer California Instruments PACS Oct.26, 14 1 Year Test Setup EUT AC Mains Power Analyzer 0.8m AC Source Test Procedure Summary The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the maximum harmonic components under normal operating conditions for each successive harmonic component in turn. The correspondent test program of test instrument to measure the current harmonics emanated from EUT is chosen. The measure time shall be not less than the necessary for the EUT to be exercised. Report #14WB E Rev. 0 - Page 26 of Washington Laboratories, Ltd.

33 5.3.5 Limits of Harmonic Current Limits for Class D Equipment Maximum permissible harmonic Maximum permissible Harmonic order (n) current per watt (ma/w) harmonic current (A) n 39 (odd harmonic only) 3.85/n /n Remark: if the EUT Power level is below 75 Watts and therefore has no defined limits Test Results Table 6 provides the test results for Harmonics. Photograph 6 shows the Harmonics test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 27 of Washington Laboratories, Ltd.

34 Table 6: Harmonic Test Data Report #14WB E Rev. 0 - Page 28 of Washington Laboratories, Ltd.

35 Report #14WB E Rev. 0 - Page 29 of Washington Laboratories, Ltd.

36 Report #14WB E Rev. 0 - Page 30 of Washington Laboratories, Ltd.

37 Photograph 6: Harmonics Test Configuration Report #14WB E Rev. 0 - Page 31 of Washington Laboratories, Ltd.

38 5.4 VOLTAGE FLUCTUATIONS & FLICKER Requirements Test Arrangement: Table Top Reference Standard: EN Clause Test Equipment Same as Section Block Diagram of Test Setup Same as Section Test Procedure The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated to produce the most unfavorable sequence of voltage changes under normal conditions During the flick measurement, the measure time shall include that part of whole operation changes. The observation period for short-term flicker indicator is 10 minutes and the observation period for long-term flicker indicator is 2 hours Limits of Voltage Fluctuation and Flick Test Item Limit Note P st 1.0 P st means Short-term flicker indicator P lt 0.65 P lt means long-term flicker indicator T max 500ms T max means maximum time that d(t) exceeds 3.3% d max (%) 4% d max means maximum relative voltage change. d c (%) 3.3% d c means relative steady-state voltage change Test Results Table 7 provides the test results for Voltage Fluctuation and Flick. Photograph 7 shows the Voltage Fluctuation and Flick test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 32 of Washington Laboratories, Ltd.

39 Table 7: Flicker Test Data Report #14WB E Rev. 0 - Page 33 of Washington Laboratories, Ltd.

40 Photograph 7: Voltage Fluctuation and Flick Test Configuration Report #14WB E Rev. 0 - Page 34 of Washington Laboratories, Ltd.

41 5.5 Electrostatic Discharge Requirements Test Arrangement: Table Top Compliance Standard: EN Clause 10 Reference Standard: IEC Clause 5 Compliance Requirement: Air = ±8kV, Severity Level 3, Performance Criterion B Contact = ±4kV, Severity Level 2, Performance Criterion B Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1 ESD Tester EM Test Dito P Jun. 05,14 1 Year Test Setup Test Procedure Summary The requirements of IEC :2008 call out an Electrostatic Discharge (ESD) test level and procedure. The intent of this test is to determine the effect of electrostatic discharge events on equipment operation. ESD is the result of potential build-up and the subsequent rapid discharge and equalization of that potential. The result of the discharge is a transient waveform that produces peak voltages up to tens of kilovolts, peak currents of a few amperes, and rise times on the order of a few nanoseconds (ns). This discharge may produce malfunction and damage to sensitive electronic equipment. Table-top EUTs are placed on a Horizontal Coupling Plane (HCP) and isolated from it by 0.5mm. The HCP was connected to a Ground Reference Plane (GRP) via a bonding strap with 470k-ohm resistors located at each end. When the Vertical Coupling Plane (VCP) was used, it was also connected to the GRP with a second bonding strap with 470k-ohm resistors located at each end. The VCP is located 10 cm from the EUT for test. The earth cable of the ESD generator was attached to the GRP. Report #14WB E Rev. 0 - Page 35 of Washington Laboratories, Ltd.

42 Contact discharge points were metallic points on the EUT that are subject to contact by operators or maintenance personnel. Air discharge points were non-conductive surfaces, indicators, and other points subject to contact. The voltage was stepped at 1 kv, 2 kv, 4 kv for contact discharge and 2 kv, 4 kv, 8 kv for air discharges. The ESD simulator was then set at the test voltage and applied 10 times (positive and negative) at intervals of one second at each discharge test point. Two ESD modes were applied: direct application of the discharge to the EUT, and indirect application of the discharge to the horizontal and vertical coupling planes. Direct application simulates a static discharge to the EUT itself and indirect application simulates a static discharge to objects placed or installed near the EUT. During test the system was monitored for performance degradation. Environmental Conditions during Electrostatic Discharge Testing Ambient Temperature: 23.1 C Relative Humidity: 49% Results Summary The EUT complied with the required performance throughout the test. Table 8 shows the ESD test results. Photograph 8,9 show the ESD test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 36 of Washington Laboratories, Ltd.

43 Table 8: ESD Test Results Applicant : EverPro Technologies Company Ltd. Test Date : Dec.11, 2014 EUT : Temperature : 23.1±0.6 M/N : EPU3HC-A1A4K050M Humidity : 49±3% Test Voltage : 5V DC from USB port Test Mode : Data Transmitting Test Engineer : Sun Pressure : 101.2±1KPa Required Performance : B Actual Performance : A&B* Air Discharge: ±2kV ±4kV ±8kV # For Air Discharge each Point Positive 10 times and negative 10 times discharge. Contact Discharge: ±2kV ±4kV # For Contact Discharge each point positive 25 times and negative 25 times discharge For the time interval between successive single discharges an initial value of one second. Performance Result Discharge Type of Voltage (kv) discharge Dischargeable Points Required Observation (Pass/Fail) ±2 Contact 1,2 B A Pass ±4 Contact 1,2 B B* Pass ±2 Air ±4 Air ±8 Air ±2 HCP-Bottom Edge of the HCP B A Pass ±2 VCP-Front Center of the VCP B A Pass ±2 VCP-Left Center of the VCP B A Pass ±2 VCP-Back Center of the VCP B A Pass ±2 VCP-Right Center of the VCP B A Pass ±4 HCP-Bottom Edge of the HCP B A Pass ±4 VCP-Front Center of the VCP B A Pass ±4 VCP-Left Center of the VCP B A Pass ±4 VCP-Back Center of the VCP B A Pass ±4 VCP-Right Center of the VCP B A Pass Discharge Points Description 1 USB Port 5 2 Metal Remark: B* Means the transmission speed slow during test, But it can be recover by itself. Discharge was considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical Coupling Plane (VCP). Report #14WB E Rev. 0 - Page 37 of Washington Laboratories, Ltd.

44 Photograph 8: ESD Test Configuration, V Plate Photograph 9: ESD Test Configuration, H Plate Report #14WB E Rev. 0 - Page 38 of Washington Laboratories, Ltd.

45 5.6 Radiated RF Susceptibility Requirements Test Arrangement : Table Top Compliance Standard: EN Clause 10 Reference Standard: EN Clause 5 Compliance Limits: Severity Level 2 3V/m (80%AM, 1kHz), 80MHz-1GHz, Performance Criterion A Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. 2#Chamber AUDIX N/A N/A Apr. 28,14 1Year 2. Signal Generator Agilent N5181A MY Oct.29, 14 1Year 3 Amplifier A&R 100W/1000M NCR NCR 4. Power Meter Anritsu ML2487A 6K Aug. 20,14 1Year 5. Power Sensor Anritsu MA2491A Aug. 20,14 1Year 6. Log-periodic Antenna A&R AT NCR NCR Test Setup Test Procedure Summary The requirements of IEC :2010 call out a Radiated Immunity test level and procedure. The system was placed in an anechoic chamber calibrated for IEC testing. The system was oriented to face the radiating antenna and cables were configured to expose at least one meter of each cable bundle. The antenna was positioned 3 meters from the equipment under test and the signal generator/amplifier operated under computer control to generate the radiated field and sweep the Report #14WB E Rev. 0 - Page 39 of Washington Laboratories, Ltd.

46 interfering signal through the test frequency range. The test level is maintained by computer control along with application of the 80% AM. During test the system was monitored for performance degradation. Environmental Conditions during Radiated RF Susceptibility Testing Ambient Temperature: 25.2 C Relative Humidity: 47 % Results Summary The EUT complied with the required performance throughout the test. Table 9 shows the Radiated RF Susceptibility test results. Photograph 10 shows the Radiated RF Susceptibility test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 40 of Washington Laboratories, Ltd.

47 Table 9: Radiated RF Susceptibility Test Results Applicant : EverPro Technologies Company Ltd. Test Date : Dec.13, 2014 EUT : USB3.0 Hybrid Active Optical Cable Temperature : 25.2±0.6 M/N : EPU3HC-A1A4K050M Humidity : 47±3% Test Voltage : 5V DC from USB port Test Mode : Data Transmitting Test Engineer : Rick Pressure : 101.2±1KPa Required Performance : A Actual Performance : A Frequency Range : 80 MHz -1000MHz Field Strength : 3V/m Modulation: AM Pulse none 1 khz 80% Frequency Rang :80 MHz -1000MHz Steps 1% Horizontal Vertical Result Required Observation Required Observation (Pass / Fail) Front A A A A Pass Right A A A A Pass Rear A A A A Pass Left A A A A Pass Remark: Report #14WB E Rev. 0 - Page 41 of Washington Laboratories, Ltd.

48 Photograph 10: Radiated RF Susceptibility Test Configuration Report #14WB E Rev. 0 - Page 42 of Washington Laboratories, Ltd.

49 5.7 Electrical Fast Transient/Burst Requirements Test Arrangement: Table Top Compliance Standard: EN Clause 10 Reference Standard: IEC Clause 5 Compliance Limits: Severity Level 2, AC Power, ±1kV, Performance Criterion B Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Burst Tester TESEQ NSG Apr. 28,14 1 Year 2. CDN TESEQ CDN Apr. 28,14 1 Year Test Setup Mains Port Test Procedure Summary The requirements of IEC :2012 call for testing the immunity of the device to "Electrical Fast Transients" or "EFTs. The EFT requirement simulates the effect on the EUT of noise generated by other users connected to the same power mains, such as that caused by contact arcing, switch closure and relay operation. EFT simulators produce a series of bursts that contain a collection of high frequency transients at predetermined intervals. Both positive and negative transient bursts were applied at the required transient repetition rate and burst repetition rate for a period not less than one minute for each line or bundle under test. During test the system was monitored for performance degradation. Report #14WB E Rev. 0 - Page 43 of Washington Laboratories, Ltd.

50 Environmental Conditions during Electrical Fast Transient/Burst Testing Ambient Temperature: 23.1 C Relative Humidity: 49 % Results Summary The EUT complied with the required performance throughout the test. Table 10 shows the Electrical Fast Transient/Burst test results. Photograph 11 and Photograph 12 show the test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 44 of Washington Laboratories, Ltd.

51 Applicant EUT Table 10: Electrical Fast Transient/Burst Test Results : EverPro Technologies Company Ltd. : USB3.0 Hybrid Active Optical Cable Test Date : Dec.11, 2014 Temperature : 23.1±0.6 M/N : EPU3HC-A1A4K050M Humidity :49±3% Test Voltage : 5V DC from USB port Test Mode :Data Transmitting Test Engineer : Sun Pressure :101.3±1KPa Required Performance : B Actual Performance : A&B* Repetition Frequency : 5 khz Burst Duration : 15ms Burst Period: 300ms Inject Time(s): 120s Inject Method: Direct Inject Line: AC Mains DC Supply Signal Line Test Voltage Performance Result Required Observation(+ ) Observation( - ) (Pass/Fail) L 0.5kV B A A Pass 1kV B B* B* Pass N 0.5kV B A A Pass 1kV B B* B* Pass PE 0.5kV B A A Pass 1kV B B* B* Pass L N 0.5kV B A A Pass 1kV B B* B* Pass L PE 0.5kV B A A Pass 1kV B B* B* Pass N PE 0.5kV B A A Pass 1kV B B* B* Pass L N PE 0.5kV B A A Pass 1kV B B* B* Pass Signal Line 0.5kV B B* B* Pass Remark: B* Means transmission speed slow during test, But it can be recover by itself. Report #14WB E Rev. 0 - Page 45 of Washington Laboratories, Ltd.

52 Photograph 11: Electrical Fast Transient/Burst Test Configuration Mains /Port Photograph 12: Electrical Fast Transient/Burst Test Configuration Telecommunication /Port Report #14WB E Rev. 0 - Page 46 of Washington Laboratories, Ltd.

53 5.8 Voltage Surge Requirements Test Arrangement: Table Top Compliance Standard: EN Clause 10 Reference Standard: IEC Clause 5 Compliance Limits: Severity Level 2 AC Power, ±0.5kV, ±1kV (Line to Line); Performance Criterion B Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1 Transient Test System EMC PARTNER TRANSIENT 2000 TRA2006 F-S-T- D-R Oct.26, 14 1 Year 2 CDN EMC PARTNER CDN-UTP8 CDN-UTP Oct.26, 14 1 Year 3 CDN EMC PARTNER CDN CDN Oct.26, 14 1 Year Test Setup Mains Port Report #14WB E Rev. 0 - Page 47 of Washington Laboratories, Ltd.

54 5.8.4 Test Procedure Summary For line-to-line coupling mode, provide a 1kV 1.2/50us voltage surge (at open-circuit condition) and 8/20us current surge to EUT selected points. At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are applied during test. Different phase angles are done individually. Record the EUT operating situation during compliance test and decide the EUT,immunity criterion for above each test. During test the system was monitored for performance degradation. Environmental Conditions during Voltage Surge Testing Ambient Temperature: 23.2 C Relative Humidity: 49 % Results Summary The EUT complied with the required performance throughout the test. Table 11 shows the Voltage Surge test results. Photograph 13 shows the Voltage Surge test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 48 of Washington Laboratories, Ltd.

55 Table 11: Voltage Surge Test Results Applicant : EverPro Technologies Company Ltd. Test Date : Dec.11, 2014 EUT : Temperature : 23.2±0.6 M/N : EPU3HC-A1A4K050M Humidity : 49±3% Power Supply : 5V DC from USB port Test Mode : Data Transmitting Test Engineer : Sun Pressure : 101.2±1KPa Required Performance : B Actual Performance : No.of pluse: ±5 A&B* Line : 1. AC Mains : 1.2/50us 10/700us 2. DC Supply : 1.2/50us 10/700us 3. Signal : 1.2/50us 10/700us Location L-N L-PE N-PE Volt Phase 500V 1kV 2kV Performance Performance Performance Required + - Required + - Required + - Result (Pass/Fail) 0 B A A B B* B* Pass 90 B A A B B* B* Pass 180 B A A B B* B* Pass 270 B A A B B* B* Pass 0 B A A B B* B* B B* B* Pass 90 B A A B B* B* B B* B* Pass 180 B A A B B* B* B B* B* Pass 270 B A A B B* B* B B* B* Pass 0 B A A B B* B* B B* B* Pass 90 B A A B B* B* B B* B* Pass 180 B A A B B* B* B B* B* Pass 270 B A A B B* B* B B* B* Pass Signal Line Remark: B* Means the transmission speed slow during test, But it can be recover by itself. Report #14WB E Rev. 0 - Page 49 of Washington Laboratories, Ltd.

56 Photograph 13: Voltage Surge Immunity Test Configuration Mains /Telecommunication Port Report #14WB E Rev. 0 - Page 50 of Washington Laboratories, Ltd.

57 5.9 Conducted RF Susceptibility Requirements Test Arrangement: Table Top Compliance Standard: EN Clause 10 Reference Standard: IEC Clause 5 Compliance Limits: Severity Level 2 3Vrms (80%AM, 1kHz), 150kHz-80MHz, Performance Criterion A Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Signal Generator Agilent N5181A MY Oct.29, 14 1 Year 2. Amplifier AR 25A250A NCR NCR 3. Amplifier AR 100A NCR NCR 4. Power meter HP 436A 2016A07891 Apr. 28,14 1Year 5. Power sensor Agilent 8482B MY Nov.06, 14 1Year 6. CDN FCC FCC-801-M Apr. 28,14 1 Year 7. CDN FCC FCC-801-M Apr. 28,14 1 Year 8. CDN FCC FCC-801-M Apr. 28,14 1 Year 9. CDN FCC FCC-801-M Apr. 28,14 1 Year 10. PC N/A N/A N/A N/A N/A 11. Attenuator Weinschel LJ092 Apr. 28,14 1 Year 12. EM Injection Clamp FCC F-203I-23mm 403 Apr. 28,14 1 Year 13. RF Cable MICABLE A M NCR NCR 14. RF Cable STORM MFR MTR NCR NCR Report #14WB E Rev. 0 - Page 51 of Washington Laboratories, Ltd.

58 5.9.3 Test Setup Test Procedure Summary Let the EUT work in test mode and test it. Mains Port The EUT are placed on an insulating support 0.1m high above a ground reference plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 10 and 30 mm (where possible). The disturbance signal described below is injected to EUT through CDN. The EUT operates within its operational mode(s) under intended climatic conditions after power on. The frequency range is swept from 0.150MHz to 80MHz using 3V signal level, and with the disturbance signal 80% amplitude modulated with a 1kHz sine wave. The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value. Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion. During test the system was monitored for performance degradation. Environmental Conditions during Conducted RF Susceptibility Testing Ambient Temperature: 24.8 C Relative Humidity: 52 % Results Summary The EUT complied with the required performance throughout the test. Table 12 shows the Conducted RF Susceptibility test results. Photograph 14,15 show the Conducted RF Susceptibility test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 52 of Washington Laboratories, Ltd.

59 Table 12: Conducted RF Susceptibility Test Results Applicant : EverPro Technologies Company Ltd. Test Date : Dec.13, 2014 EUT : Temperature : 24.8±0.6 M/N : EPU3HC-A1A4K050M Humidity : 52±3% Power Supply : 5V DC from USB port Test Mode : Data Transmitting Test Engineer : Mark Pressure : 101.2±1KPa Required Performance Frequency Range (MHz) : A Actual Performance Injected Position Voltage Level (e.m.f.) : A Required Observation Result (Pass / Fail) 0.15 ~ 20 AC Mains 3V A A PASS 20 ~ 80 AC Mains 3V A A PASS 0.15 ~ 20 Signal Mains 3V A A PASS 20 ~ 80 Signal Mains 3V A A PASS Remark: Report #14WB E Rev. 0 - Page 53 of Washington Laboratories, Ltd.

60 Photograph 14: Conducted RF Susceptibility Test Configuration Mains / Port Photograph 15: Conducted RF Susceptibility Test Configuration Telecommunication / Port Report #14WB E Rev. 0 - Page 54 of Washington Laboratories, Ltd.

61 5.10 Magnetic field immunity test Test Equipments Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Magnetic Field Tester HEAFELY MAG Apr. 28,14 1 Year Block Diagram of Test Setup Size: 1*1m 10cm wood EUT 0.8m Magnetic Field Tester AC Source Test Standard Compliance Standard: EN Clause 10 Reference Standard: IEC Clause 5 Compliance Requirement: Severity Level 1, 1A/m, Performance Criterion A Severity Levels and Performance Criterion Severity Level Magnetic Field Strength A/m Performance criterion A X. Special Test Procedure The EUT was subjected to the test magnetic field by using the induction coil of standard dimensions (1m*1m) and shown in Section The induction coil was then rotated by 90 in Report #14WB E Rev. 0 - Page 55 of Washington Laboratories, Ltd.

62 order to expose the EUT to the test field with different orientations Test Results The EUT complied with the required performance throughout the test. Table 13 shows the Conducted RF Susceptibility test results. Photograph 16 shows the Conducted RF Susceptibility test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 56 of Washington Laboratories, Ltd.

63 Applicant EUT : : Table 13: Magnetic field immunity Test Results EverPro Technologies Company Ltd. Test Date : Dec.13, 2014 USB3.0 Hybrid Active Optical Cable Temperature : 24.7±0.6 M/N : EPU3HC-A1A4K050M Humidity : 51±3% Test Voltage : 5V DC from USB port Test Mode : Data Transmitting Test Engineer : Mark Pressure : 101.2±1KPa Required Performance : A Actual Performance Test Level Testing Duration Coil Orientation Required Observation : A Result (Pass/Fail) 1A/m 5 min / coil X A A PASS 1A/m 5 min / coil Y A A PASS Remark: 1A/m 5 min / coil Z A A PASS Report #14WB E Rev. 0 - Page 57 of Washington Laboratories, Ltd.

64 Photograph 16: Magnetic field immunity Test Configuration Mains /Port Report #14WB E Rev. 0 - Page 58 of Washington Laboratories, Ltd.

65 5.11 VOLTAGE DIPS AND INTERRUPTIONS TEST Test Equipment Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Main Interference Simulator HAEFELY PLINE Apr. 28,14 1 Year Block Diagram of Test Setup EUT AC Mains Main Interference Simulator AC Mains 0.8m Requirements Test Arrangement: Table Top Compliance Standard: EN Clause 10 Reference Standard: IEC Clause 5 Compliance Requirement: Performance Criterion: B, C Severity Levels and Performance Criterion Test Level %UT Voltage dip and short interruptions %UT Duration (in period) Performance Criterion B B C Test Results The EUT complied with the required performance throughout the test. Table 14 shows the Voltage Dips/Interrupts test results. Photograph 17 shows the Voltage Dips/Interrupts test configuration Areas of Concern None. Report #14WB E Rev. 0 - Page 59 of Washington Laboratories, Ltd.

66 Applicant : EUT : M/N : Power Supply : Test Engineer : Table 14: Voltage Dips/Interrupts Test Results EverPro Technologies Company Ltd. USB3.0 Hybrid Active Optical Cable EPU3HC-A1A4K050M 5V DC from USB port Mark Test Date : Temperature : Humidity : Test Mode : Pressure : Dec.13, ±0.6 51±3% Data Transmitting 101.1±1KPa Required Performance Test Level % U T : B&C Actual Performance : Voltage Dips & Short Interruptions % U T Duration (in period) A&C* Phase Angle Required Observation Result (Pass / Fail) P B A PASS P C A PASS P C C* PASS Note 1: UT is the rated voltage for the equipment. Note 2: The frequency of the test voltage shall be within ±2% of the rated frequency, the output voltage shall be within ±5% of the rated voltage. Remark: C* Means the EUT stop working, required manual involved to restart the data transfer. Report #14WB E Rev. 0 - Page 60 of Washington Laboratories, Ltd.

67 Photograph 17: Voltage Dips/Interrupts Test Configuration Report #14WB E Rev. 0 - Page 61 of Washington Laboratories, Ltd.

68 6 Attachment (EUT Photograph) EUT Model: EPU3HC-A1A4K050M EUT Photo #1 Front View EUT Photo #2 Uncover View Report #14WB E Rev. 0 - Page 62 of Washington Laboratories, Ltd.

69 EUT Photo #3 Uncover View EUT Photo #4 Uncover View Report #14WB E Rev. 0 - Page 63 of Washington Laboratories, Ltd.

70 EUT Photo #5 Uncover View Report #14WB E Rev. 0 - Page 64 of Washington Laboratories, Ltd.

71 7 Appendix A. Declaration of Conformity According to the European EMC Directive (2004/108/EC), the conformity of a device to the Directive shall be certified by an EC declaration of conformity issued by the manufacturer or his authorized representative established within the European Community. If neither the manufacturer nor his authorized representative is established in the European Community, the EC declaration of conformity shall be the responsibility of the person who places the device on the European Community market. The EC declaration of conformity shall be held at the disposal of the competent authority for ten years following the last placement of the device on the market (i.e., 10 years after that last device has been sold) and must contain the following information: - Description of the device to which the declaration refers, - Reference to the specifications under which conformity is declared, and, where appropriate, the national measures implemented to ensure the conformity of the provisions of the Directive, - Identification of the signatory empowered to bind the manufacturer or his authorized representative. An example of an EC declaration of conformity is shown on the next page. Please note that Audix Technology (Shenzhen) Co., Ltd. operates as a contract-testing laboratory and provides test results to support the EC declaration of conformity. However, under the EC's current regulations, it is up to the manufacturer/importer to declare conformity to the proper standards. Although WLL can provide technical guidance, the final determinations as to which standards apply to the product and whether the product conforms to the standards is the responsibility of the manufacturer/importer.. Report #14WB E Rev. 0 - Page 65 of Washington Laboratories, Ltd.

72 Manufacturer's Name : S a m p l e DECLARATION OF CONFORMITY Application of Council Directive(s): 2004/108/EC Standard(s) to which Conformity is Declared: EN 55022:2010+AC:2011 EN 55024:2010 EverPro Technologies Company Ltd. Manufacturer's Address: 4# Guanshan Er Road, Wuhan P,R, China Importer's Name: Importer's Address: Type of Equipment: Model Number: EPU3HC-NNMMXYYYL Year of Manufacture: I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s). Place: (Signature) Date: (Full Name) Report #14WB E Rev. 0 - Page 66 of Washington Laboratories, Ltd.

73 B. Marketing and Labeling Instructions Labeling Requirements According to the European EMC Directive (2004/108/EC), the EC conformity marking for a device shall be affixed by the manufacturer, or his authorized representative established within the European Community. The EC conformity marking can be affixed to the device, packaging, instructions for use, or guarantee certificate. The EC conformity marking shall consist of the letters "CE" (as shown below). NOTE: The grid is to show proportions only. Marketing Requirements This report and the manufacturer's subsequent EC declaration of conformity are only valid for the technical standards (i.e. European Norms) noted in this report. If these technical standards are updated or additional technical standards are adopted, that are applicable to this device, then the device should be tested to these updated or new standards to ensure continued compliance with the EMC Directive (2004/108/EC). If changes to the original equipment are made, then these changes should be reviewed to ensure that they do not effect compliance with the technical standards. If the changes are determined to change the EMC characteristics of the device then the device should be retested to the applicable technical standards. Report #14WB E Rev. 0 - Page 67 of Washington Laboratories, Ltd.

EverPro Technologies Company Ltd.

EverPro Technologies Company Ltd. CE Marking For the EverPro Technologies Company Ltd. Model: EPU3HC-AXBXXYYYM WLL Report#15WB1121047E Rev. 0 Prepared for: EverPro Technologies Company Ltd. 4# Guanshan Er Road, Wuhan 430073 P,R, China

More information

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU

More information

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name: Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013

More information

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by

More information

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name: APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen

More information

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC. Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial

More information

1 SUMMARY OF STANDARDS AND RESULTS

1 SUMMARY OF STANDARDS AND RESULTS 1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard

More information

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27 15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25 15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE

More information

Test Report GUANGDONG EAST POWER CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014

More information

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Guangdong East Power Co., Ltd. Uninterruptible Power Systems Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012

More information

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi EMC TEST REPORT For Shenzhen Ruideou Keji Youxian Gongsi Product Name: Trademark: Milligram Scale WAOAW Model Number: W-01-50 Prepared For : Address: Prepared By : Address: Shenzhen Ruideou Keji Youxian

More information

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,

More information

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

PT. SARANA KARYA SOLUSINDO.

PT. SARANA KARYA SOLUSINDO. Shenzhen BST Technology Co., Ltd. PT. SARANA KARYA SOLUSINDO. EMC REPORT Prepared For : PT. SARANA KARYA SOLUSINDO. Puri Surya Jaya J1. 29 Cluster Vancouver, Gedangan, Sidoarjo, Jawa Timur - Indonesia

More information

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC TEST REPORT. Report No.: CE10-LIE040101E EMC TEST REPORT Report No.: CE10-LIE040101E Product: LED TUBE Model No.: T10, T8, T5 Applicant: Shenzhen Saiju Electronic Co., Ltd. Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen,

More information

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE EMC TEST REPORT For SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD Product Name: Pure sine wave power inverter Trademark: Model : Prepared For : Address: Prepared By : Address: ML-1000W ML-300W---ML-8000W.

More information

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2

More information

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province. DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED ITaste vv Model No.: ITaste vv Prepared for : INNOKIN TECHNOLOGY CO., LIMITED Address : 3# Floor, #B Building, Heng Chang Rong Industrial Park, Gonghe

More information

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20 Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB

More information

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :

More information

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY

More information

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC VERIFICATION SUMMARY Report No.: SZHH EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA

More information

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Activision Publishing, Inc USB Wireless Receiver for Wii & USB Wireless Receiver for PS3 Trade Name : Activision. Model Number: 83973791/84148791

More information

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared

More information

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG SWITCHING POWER SUPPLY Model No. HSM-50-12~48 HSM-15-5~24, HSM-35-12~48. : DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG : No.3 Tengfei Road,

More information

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758 Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller Test Report Applicant: Product Name: Brand Name: Model No.: Apricus Solar Co., Ltd. Multi-Function Differential Controller Apricus MFC-1 Date of Receipt : Jan. 04, 2012 Date of Test: Jan. 04, 2012 Date

More information

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Test Report. Ningbo Goldmore Industrial Co.,Ltd. Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date

More information

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech

More information

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,

More information

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Page 1 of 48 EMC TEST REPORT for Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Prepared for : Coliy Technology Co.,Ltd. Address : Block B,9 th Floor,Xinzhongtai Business Building,Gushu 2nd Road,Xi Town,Bao

More information

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday

More information

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42. EMC TEST REPORT For Shenzhen Smar TEC Technology Company Smart Charger For Li-Ion&Lifepo4 Battery Pack Model No.:SPS-F12S02-021(42.6V/2A) Prepared for : Shenzhen Smar TEC Technology Company Address : 4-5/F.,

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Proware Technologies Co., Ltd. Wireless High Gain USB Adapter. Model No.

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Proware Technologies Co., Ltd. Wireless High Gain USB Adapter. Model No. FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Proware Technologies Co., Ltd. Wireless High Gain USB Adapter Model No.: PW-DN4210D FCC ID: WWMDN4210DV1 Prepared for : Proware Technologies Co.,

More information

Test Report GUANGDONG EAST POWER CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA902IIRTS, EA902IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014

More information

ELECTRONICS TESTING CENTER(ETC), TAIWAN

ELECTRONICS TESTING CENTER(ETC), TAIWAN File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,

More information

EMC TEST REPORT. according to

EMC TEST REPORT. according to EMC TEST REPORT according to European Standard EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2006, EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:Edition 1.2:2001-04, IEC

More information

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System. Model No.: GTK-XB7 IC: 409B-GTKXB7

RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System. Model No.: GTK-XB7 IC: 409B-GTKXB7 IC:409B-GTKXB7 RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of Sony Corporation Home Audio System Model No.: GTK-XB7 IC: 409B-GTKXB7 Prepared for : Sony Corporation 1-7-1 Konan, Minato-ku, Tokyo 108-0075

More information

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S EMC TEST REPORT For Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope Model No.: MS520S Additional Model No: Please Refer To Page 47 Prepared for Address : Shenzhen Micsig Instruments

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203

More information

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD CE REPORT CE EMC Test Report Equipment under Test: Model /Type: Applicant: Address: Manufacturer: Address: Laboratory: Address: Report Number Brush D.C. Motor D5D120-24GU D2D10-12GN, D2D10-24GN, D2D10-36GN,

More information

9. Electrostatic Discharge Immunity Test (ESD)

9. Electrostatic Discharge Immunity Test (ESD) 9. Electrostatic Discharge Immunity Test (ESD) Test Mode: Mode 1 Final Test Result : PASS Pass Performance Criteria : A Required Performance Criteria: B Basic Standard : IEC 61000-4-2:Edition 1.2:2001-04

More information

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE

More information

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter EMC TEST REPORT For Shenzhen Huanxi Technology Co., Ltd Product Name: Smart Self-balancing Scooter Trademark: Model : Prepared For : Address: Prepared By : Address: N/A X1S6.5 X1L6.5, X1S 8, X1L8. Shenzhen

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10 FCC ID: AK8SRSXB10 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Sony Corporation Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10 Prepared for : Sony Corporation 1-7-1 Konan Minato-ku Tokyo, 108-0075

More information

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58 EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58 Prepared for : TEA-Energy China Limited Address : 0100029 Building,

More information

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003 Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20 EMC TEST REPORT For Soma Medical (Sabah) Sdn Bhd (1248058-D) UVGI AIR STERILIZER Model No.: SM 20 Prepared For : Soma Medical (Sabah) Sdn Bhd (1248058-D) : Block E, Lot 28, 2nd floor, Signature Office,

More information

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools

More information

EMC test report AU01+E04

EMC test report AU01+E04 Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of

More information

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45 REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business

More information

EMC TEST REPORT. According to

EMC TEST REPORT. According to EMC TEST REPORT According to EN 55022:2006/A1:2007 (Class B) EN 55024 : 1998/ A1:2001/ A2:2003 EN 61000-3-2 : 2006/A1:2009/A2:2009 IEC 61000-4-2 : 2008 EN 61000-3-3 : 2008 IEC 61000-4-3 : 2010 IEC 61000-4-4

More information

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by  Project Number EMT08J027 Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System GTK-XB90 FCC ID: AK8GTKXB90

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System GTK-XB90 FCC ID: AK8GTKXB90 FCC ID:AK8GTKXB90 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Sony Corporation Home Audio System GTK-XB90 FCC ID: AK8GTKXB90 Prepared for : Sony Corporation 1-7-1 Konan Minato-ku Tokyo, 108-0075

More information

EMC TEST REPORT For : SHENZHEN HITEVISION TECHNOLOGY CO., LTD. Interactive Whiteboard

EMC TEST REPORT For : SHENZHEN HITEVISION TECHNOLOGY CO., LTD. Interactive Whiteboard EMC TEST REPORT For SHENZHEN HITEVISION TECHNOLOGY CO., LTD. Interactive Whiteboard Model No.: HiteVision: HV-I7xx, HV-I7xxy, HV-I71xx, HV-I71xxy; WhiteBoard: IR70-xx, IR70-xxy, IR70-1xx, IR70-1xxy, IR798yy,

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Mad Catz Inc. Model Number: 90630C FCC ID: P25S790630AC

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Mad Catz Inc. Model Number: 90630C FCC ID: P25S790630AC FCC PAT 15C TEST EPOT FO CETIFICATION On Behalf of Mad Catz Inc. Product: UNIV Tritton Headset Wireless Stereo Kunai Model Number: 90630C FCC ID: P25S790630AC Prepared for : Mad Catz Inc. 7480 Mission

More information

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan EMC TEST REPORT For MPP SOLAR INC Model Number: PIP 2424MS Prepare for Address : MPP Solar Inc : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan Prepare by Address : MPP Solar In : 4F, No. 50-1,

More information

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16

More information

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U EMC TEST REPORT For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U Prepared for Address : PEAK ELECTRONIC(HUIZHOU)CO., LTD. :

More information

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co. ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03) TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-10P Report Type: Amended Report

More information

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader EMC TEST REPORT For MICRO-STAR INT'L CO.,LTD USB Card Reader Model : StarReader Prepared For : MICRO-STAR INT'L CO.,LTD No.69, Lide St., Jhonghe City, Taipei County 235, Taiwan Prepared By : Shenzhen Best

More information

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE

More information

EMC TEST REPORT For Prokits Industries Co., Ltd.

EMC TEST REPORT For Prokits Industries Co., Ltd. Page 1 of 34 EMC TEST REPORT For Prokits Industries Co., Ltd. Temperature-Controlled Soldering Station Model No.:SS-206/207 Series Test Report Number : ESTSZ110701228E EST COMPLIANCE LABORATORY LIMITED

More information

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba FCC ID. AZPT10CG-24G Page 1 of 56 APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba Prepared for : Futaba Corporation 1080

More information

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated Page 1 of 17 FCC 15.209 & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report for A Acer Incorporated 8F., No.88, Sec. 1, Xintai 5th Rd., Xizhi, New Taipei City 22181, Taiwan (R.O.C) Product

More information

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC standards. Presented by: Karim Loukil & Kaïs Siala Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards

More information

CONFORMANCE TEST REPORT FOR EN /-6

CONFORMANCE TEST REPORT FOR EN /-6 CONFORMANCE TEST REPORT FOR EN 301489-1/-6 Client: Product: Model: Manufacturer/supplier: Aztech Systems Limited DECT Phone H315-S1 (FP) Aztech Systems Limited Date test item received: 2006/05/09 Date

More information

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

More information

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10 CE/EMC TEST REPORT For HK QNOVATOR TECHNOLOGY CO.,LIMITED Product Name: Vacuum Tube Amplifier Trademark: Model Number: Prepared For: Address: Gemtune GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05,

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report

More information

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57 EMC TEST REPORT For Global Tech China Limited 120/200 Watt Mightylite Model No.: 0022031 Additional Model No: Please Refer To Page 57 Prepared for Address : Global Tech China Limited : 3 Flat A, Wai Yip

More information

EMC Test report for LED Panel Light Models , , , , ,

EMC Test report for LED Panel Light Models , , , , , 4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,

More information

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U Prepared for : Gztod. Co., Ltd. Address : 2-5/F, Building A4, Huimingsheng Industrial Park, Tongfuyu Dingfeng High-Tech District,

More information

APPLICATION FOR CERTIFICATION On Behalf of. Philips Consumer Electronics Company. Digital Audio Player

APPLICATION FOR CERTIFICATION On Behalf of. Philips Consumer Electronics Company. Digital Audio Player APPLICATION FOR CERTIFICATION On Behalf of Philips Consumer Electronics Company Digital Audio Player Model Number SA5225BT/37 Brand Name PHILIPS Prepared for : Philips Consumer Electronics Company 3029

More information

TEST REPORT. Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China

TEST REPORT. Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China TEST REPORT Applicant Address Innokin Technology Co.,Ltd Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China Manufacturer or Supplier Address Product Innokin Technology

More information

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,

More information

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 EN 301 489-17 v3.1.1 TEST REPORT FOR Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 Prepared for Texas Instrument 2900 Semiconductor Drive Santa

More information

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46 TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5

More information

EMC TEST REPORT. Draft ETSI EN /-3 For

EMC TEST REPORT. Draft ETSI EN /-3 For EMC TEST REPORT Draft ETSI EN 301 489-1/-3 For Applicant: CNEX AIE SL Address: Camíde Ca la Madrona, 5-7, 08304, Mataró, Barcelona, Spain Product Name: massager Model Name: 107530,107738,108216,108339,108735,404936,404837,405094,

More information

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and

More information

Test Report. Model No.: NF594XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF594-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 )

Test Report. Model No.: NF594XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF594-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 ) Test Report Applicant: Product Name: Brand Name: Jetway Information Co., Ltd Motherboard/Barebone N/A Model No.: NF594XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF594-YYYY-ZZ (X,Y & Z: Stands for

More information

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015. TEST REPORT Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor, Lantian Building,

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass Seite 2 von 35 Page 2 of 35 TEST SUMMARY 5.1.1 HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Pass 5.1.3 CONDUCTED DISTURBANCE AT THE MAINS PORTS RESULT:

More information

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19 EMC TEST REPORT Page : 1 of 19 Equipment Under Test Model No. Applicant Address of Applicant : Bluetooth Headset : FB-HS01 : Formosa Teletek Corporation : 358, Huaya 2 nd Rd., Gueishan shiang, Taoyuan,

More information

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E CE-EMC Test Report Applicant: Product Description: Tested Model: Test Standards: Report No.: United GULF GATE Trd. Co. XonTel MS EN 55032:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024 :2010+A1 :2015

More information

CE EMC Test Certification

CE EMC Test Certification Certification No.: EC57C001 CE EMC Test Certification According to European Standard EN 55022:1998/A1:2000/A2:2003 Class A, EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 55024:1998/A1:2001/A2:2003

More information

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD. EMC Testing Report Equipment Under Test MSI StarCam Genie Model Number Serial No. Applicant Address of Applicant StarCam Genie N/A MICRO-STAR INT L CO., LTD. No.69, Lide St., Jhonghe City, Taipei County

More information