Mass Flow and Density Transmitter

Size: px
Start display at page:

Download "Mass Flow and Density Transmitter"

Transcription

1 RFT9739 Product Data Sheet PS EU October 1999 Mass Flow and Density Transmitter

2 RFT9739 transmitter The RFT9739 transmitter works with Micro Motion sensors to provide precision fluid measurement in a wide variety of fluid applications. The RFT9739 has modular, microprocessor-based electronics, incorporating ASIC digital technology with a choice of digital communication protocols. Combined with a Micro Motion sensor, the RFT9739 provides accurate mass flow, density, temperature, and volumetric measurements of process fluids. With a pressure transmitter properly installed in the flow loop, the transmitter also indicates pressure. The RFT9739 simultaneously transmits four output signals. Two independently configured analog outputs can each indicate flow rate, density, temperature, or pressure. A frequency/pulse output indicates flow rate or total. A control output indicates flow direction, a fault, or flowmeter zero in progress. The RFT9739 is available in field-mount and rackmount versions. The field-mount transmitter is housed in a IP65 (NEMA 4X) explosion-proof enclosure that provides easy access to the electronics module, and allows the transmitter and sensor to be installed in the same hazardous area. The rack-mount transmitter's compact housing is ideal for control room installations. The RFT9739 features user-selected Bell 202 or RS-485 serial standard for HART or Modbus communication protocols. For configuration in the field, use Micro Motion ProLink software, Fisher-Rosemount ä AMS software, or a Rosemount Model 275 HART Communicator. An integral liquid crystal display (LCD) is standard on the rack-mount model, optional with the field-mount version. Use the display to set communication parameters, read process variables, reset flow totalizers, and view diagnostic messages. Choose from a wide range of sensors to suit your application. The RFT9739 is compatible with Micro Motion ELITE sensors, the most accurate Coriolis meters available today. Or choose Micro Motion F-Series sensors, standard or high-pressure Model D sensors, Model DT hightemperature sensors, or Model DL sanitary sensors. Model RFT9739 transmitters support PlantWeb ä field-based architecture, a scalable way to use open and interoperable devices and systems to build process solutions of the future. 2 RFT9739 Transmitter

3 RFT9739 performance specifications Sensor model Flow accuracy* ELITE liquid ± 0,10% ± [(zero stability/flow rate) x 100]% of rate ± 0,50% ± [(zero stability/flow rate) x 100]% of rate F-Series liquid ± 0,20% ± [(zero stability/flow rate) x 100]% of rate ± 0,70% ± [(zero stability/flow rate) x 100]% of rate D (except DH38), DL and DT liquid ± 0,15% ± [(zero stability/flow rate) x 100]% of rate ± 0,65% ± [(zero stability/flow rate) x 100]% of rate DH38 liquid ± 0,15% ± [(zero stability/flow rate) x 100]% of rate ± 0,50% ± [(zero stability/flow rate) x 100]% of rate Sensor model Flow repeatability* ELITE liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rate ± 0,25% ± [(zero stability/flow rate) x 100]% of rate F-Series liquid ± 0,10% ± [½(zero stability/flow rate) x 100]% of rate ± 0,35% ± [(zero stability/flow rate) x 100]% of rate D (except DH38), DL and DT liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rate ± 0,30% ± [(zero stability/flow rate) x 100]% of rate DH38 liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rate ± 0,25% ± [½(zero stability/flow rate) x 100]% of rate Density accuracy Density repeatability Sensor model kg/m 3 kg/m 3 ELITE (except high-pressure CMF010P) liquid ± 0,5 ± 0,2 ± 2,0 ± 1,0 ELITE high-pressure CMF010P liquid ± 2,0 ± 1,0 ± 8,0 ± 4,0 F-Series liquid only ± 2,0 ± 1,0 D6, D12, D25, D40, liquid only ± 2,0 ± 1,0 DH100, DH150 DH6, DH12, DH25, liquid only ± 4,0 ± 2,0 DH38 D65, DL65, DT65, liquid only ± 1,0 ± 0,5 D100, DT100, D150, DT150, DH300 DL100, DL200, liquid only ± 0,5 ± 0,2 D300, D600 Sensor model Temperature accuracy Temperature repeatability All models ± 1 C ± 0,5% of reading in C ± 0,2 C * Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications are based on reference conditions of water at 20 to 25 C, and 1 to 2 bar unless otherwise noted. For measurement specifications, refer to product specifications for each sensor. For values of zero stability, refer to product specifications for each sensor. RFT9739 Transmitter 3

4 RFT9739 functional specifications Output signals Analog Two independently configured analog outputs, designated as primary and secondary, can represent mass or volumetric flow rate, density, temperature, event 1 or event 2. These outputs cannot be changed from active to passive. With a pressure transmitter, outputs can also provide indication for pressure. Internally powered, can be selected as 4-20 ma or 0-20 ma current outputs. Galvanically isolated to ± 50 VDC, 1000 ohm load limit. Out-of-range capability: 0-22 ma on 0-20 ma output; 3,8-20,5 ma on 4-20 ma output. Milliamp (ma) output rangeability Flow Maximum span determined by sensor specifications Range limit determined by sensor maximum rate Minimum recommended span (% of nominal flow range): ELITE sensors 2,5% F-Series sensors 10% D, DL, and DT sensors 10% D300 and D600 sensors 5% High-pressure (DH) sensors 20% typical Density Range limit: 0 to 5000 kg/m 3 Minimum span: 100 kg/m 3 Temperature Range limit: 240 to 450 C Minimum span: 20 C Frequency One frequency/pulse output can be configured to indicate mass flow rate, volumetric flow rate, mass total (inventory), or volume total (inventory), independent of analog outputs. Internally powered, 0-15 V square wave, unloaded; 2,2 kohm impedance at 15 V, galvanically isolated to ± 50 VDC. In open collector configuration: sinking capability, 0,1 amps in on condition (0 volt level), 30 VDC compliance in off condition. Signal can be scaled up to Hz. Out-of-range capability to Hz. Programmable pulse width for low frequencies. Dual-channel frequency (rack-mount transmitter only) Approved for custody transfer applications, a dual-channel frequency output, referred to as frequency A and frequency B. Phase shift between channels is 90 degrees. Output derived from the primary frequency, and represents the same process variable as the frequency output, but with half the frequency. All specifications match frequency/pulse output except: Signal can be scaled up to 5000 Hz; out-of-range capability to 7500 Hz. The output complies with VDE/VDI Optocoupler (rack-mount transmitter only) The optocoupler is an externally powered output. Signal voltage: low level 0-2 VDC, high level VDC. Maximum signal current 0,01 amp. Maximum capacitive load 150 nf at 10 khz. Output is derived from the primary frequency, and represents the same process variable as the frequency/pulse output. The output complies with VDE/VDI Control One control output can represent flow direction, fault alarm, zero in progress, event 1 or event 2. Internally powered, digital level, 0 or 15 V, 2,2 kohm pull-up, galvanically isolated to ± 50 VDC. In open collector configuration: sinking capability, 0,1 amps in on condition (0 volt level), 30 VDC compliance in off condition. Digital Switch allows selection of Bell 202 and/or RS-485 serial standard. Bell 202 signal is superimposed on primary variable ma output, and available for host system interface. Frequency 1,2 and 2,2 khz, amplitude 0,8 V peak-to-peak, 1200 baud. Requires 250 to 1000 ohms load resistance. RS-485 signal is a ± 5 V square wave referenced to transmitter ground. Baud rates between 1200 baud and 38,4 kilobaud can be selected. 4 RFT9739 Transmitter

5 Additional outputs Sensor frequency For use with Micro Motion peripheral devices, 8 V peak-topeak at sensor natural frequency, referenced to sensor ground, 10 kohm output impedance. Sensor temperature For use with Micro Motion peripheral devices, 5 mv/ C, referenced to signal ground, 10 kohm output impedance. API gravity output API gravity references to 15 C. Uses correlation based on API equation 2540 for Generalized Petroleum Products. Accuracy of corrected density calculation relative to API-2540 from 0 to 300 F: Process fluid g/cc kg/m 3 API Diesel, heater, fuel oils ± 0,0005 ± 0,5 ± 0,2 Jet fuels, kerosenes, solvents ± 0,002 ± 2,0 ± 0,5 Crude oils, JP4 ± 0,004 ± 4,0 ± 1,0 Lube oils ± 0,01 ± 10 ± 2,0 Gasoline, naphthenes ± 0,02 ± 20 ± 5,0 Minimum 4-20 ma span: 10 API. Standard volume Indicates standard volume at 60 F or 15 C for Generalized Petroleum Products when API is selected as density unit of measure. Accuracy of standard volume measurements depends on accuracies of mass flow rate, density, temperature and temperature-corrected API calculation, and can be estimated using the root mean square method. Standard volume accuracy of ± 0,5% of rate is typically attainable for Generalized Petroleum Products such as fuel oils, jet fuels, and kerosenes. Pressure compensation Analog input can accept a signal from a pressure transmitter for pressure compensation of flow and density. Range, 0-25 ma. Can be used to power independent pressure or differential pressure transmitter. Voltage sourcing capability, 15 V. Input impedance, 100 ohms. Slug-flow limits Transmitter senses density outside limits. Flow output remains at last measured value, for a programmed time of 0-60 seconds, before defaulting to the level that represents zero flow. Damping Wide range of programmed filter time constants for damping on flow, density, and temperature. Additional damping may be applied to ma outputs. Fault indication Faults can be indicated by user-selected downscale (0 ma or 0-2 ma, 0 Hz) or upscale (22,2-24 ma, khz) output levels. Control output can also be configured to indicate a fault condition at 0 V. Output testing Current source Transmitter can produce a specified current between 0 and 22 ma on 0-20 ma output, or between 2 and 22 ma on 4-20 ma output. Frequency source Transmitter can produce a specified frequency between 0,1 and Hz. Local display Optional for field-mount transmitter. Standard on rack-mount transmitter. Display is a 2-line, 16-character, alphanumeric liquid crystal display (LCD). Using the transmitter's scroll function, the user can view flow rate, density, temperature, mass and volume totals and inventory levels, and status messages on the LCD. A reset button allows the user to reset the transmitter's flow totalizers and communication parameters, as well as zero the flowmeter. Low-flow cutoff Flow values below the low-flow cutoff cause analog, frequency, and digital outputs to default to zero flow levels. Each ma output may be configured for an additional low-flow cutoff. RFT9739 Transmitter 5

6 RFT9739 functional specifications continued Power supply options Field-mount transmitter 85 to 250 VAC, 48 to 62 Hz, 10 watts typical, 15 watts maximum, fused with IEC mA/250V, time-lag, subminiature. All AC-powered RFT9739 transmitters comply with low-voltage directive 73/23/EEC per IEC with Amendment to 30 VDC, 7 watts typical, 14 watts maximum, fused with IEC ,6A/125V, time-lag, subminiature. At startup, transmitter power source must provide a minimum of 1,6 amperes of short-term current at a minimum of 12 volts at the transmitter's power input terminals. Rack-mount transmitter 110/115 VAC ± 25%, 48 to 62 Hz, 10 watts typical, 15 watts maximum, fused with UL/CSA 250mA/250V, time-lag, 5x20mm 220/230 VAC ± 25%, 48 to 62 Hz, 10 watts typical, 15 watts maximum, fused with UL/CSA 250mA/250V, time-lag, 5x20mm All AC-powered RFT9739 transmitters comply with low-voltage directive 73/23/EEC per IEC with Amendment 2. Environmental limits Ambient temperature limits Field-mount transmitter Without display Operating 30 to 55 C Storage 40 to 80 C With display Operating 10 to 55 C Storage 20 to 70 C Rack-mount transmitter Operating 0 to 50 C Storage 20 to 70 C Humidity limits Meets SAMA PMC Vibration limits Field-mount transmitter Meets SAMA PMC , Condition 2 Rack-mount transmitter Meets SAMA PMC , Condition 1 12 to 30 VDC, 7 watts typical, 14 watts maximum, fused with UL/CSA 2A/125V, medium-lag, 5x20mm. At startup, transmitter power source must provide a minimum of 2 amperes of short-term current at a minimum of 12 volts at the transmitter's power input terminals. 6 RFT9739 Transmitter

7 Environmental effects EMI effect on sensor and transmitter Transmitters with enhanced EMI immunity meet the requirements of the EMC directive 89/336/EEC per EN (January 1992) for field-mount RFT9739, EN (January 1992) for rack-mount RFT9739, and EN (March 1995), when operated at nominal rated flow measurement range. Enhanced EMI immunity is required for transmitters installed in the European Community after 1 January For specific EMC effects within the EC, the Technical EMC file may be reviewed at Micro Motion Veenendaal. All RFT9739 transmitters meet the requirements of SAMA PMC 33.1 (October 1978), Class 1, A, B, C (0,6% span) at nominal flow rate. All RFT9739 transmitters meet the recommendations of ANSI/IEEE C62.41 (1991) for surge and EFT. To meet the above specifications, the transmitter must be installed with an approved Micro Motion sensor, and the sensor cable must be either doubly shielded with full contact glands, or installed in continuous, fully bonded, metallic conduit. The transmitter and sensor must be directly connected to a low-impedance (less than 1 ohm) earth ground. Transmitter outputs must be run in standard twisted-pair, shielded instrument wire. Ambient temperature effect on transmitter On milliamp outputs ± 0,005% of span/ C On temperature output ± 0,01 C/ C On milliamp input ± 0,01% of span/ C Hazardous area classifications Field-mount transmitter Without display UL and CSA Class I, Div. 1, Groups C and D. Class II, Div. 1, Groups E, F, and G explosion proof when installed with approved conduit seals. Otherwise, Class I, Div. 2, Groups A, B, C, and D. Provides nonincendive sensor outputs for use in Class I, Div. 2, Groups A, B, C, and D; or intrinsically safe sensor outputs for use in Class I, Div. 1, Groups C and D or Class II, Div. 1, Groups E, F, and G. CENELEC EEx d [ib] IIC T6 flameproof when installed with approved cable glands. Otherwise, [EEx ib] IIC. SAA Exd [ib] IIC T6 With display UL and CSA Class 1, Div. 2, Groups A, B, C, and D. Provides intrinsically safe sensor outputs for use in Class I, Div. 1, Groups C and D; nonincendive sensor outputs for use in Class I, Div. 2, Groups A, B, C, and D. CENELEC Safe area only. Intrinsically safe sensor outputs for [EEx ib] IIC. SAA Ex [ib] IIC IP66 UL Division 2 nonincendive parameters for all RFT9739 field-mount transmitters Analog output Frequency output Parameter (Terminals 17-18, 19-20) (Terminals 14-16) V OC 36,5 V 16 V I SC 22 ma 51 ma C a 0,135 µf 1,5 µf L a 100 mh 37 mh Rack-mount transmitter UL Non-hazardous locations. Provides nonincendive sensor outputs for use in Class I, Div. 2, Groups A, B, C, and D; or intrinsically safe sensor outputs for use in Class I, Div. 1, Groups C and D or Class II, Groups E, F, and G. CSA Non-hazardous locations. Connections to sensor are intrinsically safe for use in Class I, Div. 1, Groups C, D, and Class II, Groups E, F, and G. CENELEC Safe area only. Connections to sensor are intrinsically safe in [EEx ib] IIC areas. RFT9739 Transmitter 7

8 RFT9739 field-mount physical specifications Housing IP65 (NEMA4X ) epoxy polyester painted cast aluminum Cable gland entrances Three 3/4-14 NPT on transmitter base Electrical connections Screw terminal blocks for all signal wiring can be unplugged. Fixed screw terminals for power connections. Screw terminal on housing for chassis ground. Studs for intrinsic safety ground. Weight (without display) 5,7 kg Dimensions in mm 4X Æ 9 71 Minimum clearance for removal of cover: without display 292 with display 335 Optional display Optional display x 3/4-14 NPT conduit opening Æ RFT9739 Transmitter

9 RFT9739 rack-mount physical specifications Housing 19-inch rack, European standard DIN 41494: 128 mm (3HE) high x 142 mm (28TE) wide x 231,9 mm deep. Electrical connections Two connectors per DIN 41612, type F. Choose either fast-on (wire-pin) solder connectors (standard) or Y-shaped screw-terminal connectors (optional). Sensor connectors and output connectors are not interchangeable. Weight 2,0 kg Dimensions in mm TE With Y-shaped screw terminals 281,9 With fast-on/solder terminals 255,6 DIN male connectors 3HE 128,4 122,4 111,1 OUTPUT SENSOR 28TE 18,7 212,3 13TE 141,7 4,7 234,6 66 RFT9739 Transmitter 9

10 RFT9739 field-mount model number matrix RFT9739 Transmitter Model RFT9739 transmitter Housing options E Field-mount, without display, IP65 (NEMA 4X), explosion-proof D Field-mount, with display, IP65 (NEMA 4X) Power-supply options VAC VDC S E Configuration Standard Enhanced EMI immunity (CE compliant) requires installation with Micro Motion cable type RFP or RFT installed in conduit, or type CBPS or CBPA installed with approved cable glands Approvals M Micro Motion standard (no approvals) U UL B CENELEC intrinsically safe sensor outputs F CENELEC intrinsically safe sensor outputs/flameproof transmitter not available with housing code D Glands Available with approvals codes M, C, and S Available with approvals code U only with housing code D A No fittings or glands Available with approvals code U only with housing code E J 1 x explosion-proof seal fitting K 3 x explosion-proof seal fitting Available with approvals code B (non-eexd) B 1 x gland, nickel-plated brass (7-12,5 mm) C 3 x gland, nickel-plated brass (7-12,5 mm) Available with approvals code F only with housing code E D 1 x gland, nickel-plated brass (8-12 mm/10,5-16 mm) E 1 x gland, SS (8-12 mm/10,5-16 mm) F 3 x gland, nickel-plated brass (8-12 mm/10,5-16 mm) G 3 x gland, SS (8-12 mm/10,5-16 mm) Example* RFT9739 E 4 E B C *Example: RFT9739 E 4 E B C = RFT9739 field-mount transmitter in IP65 (NEMA 4X) explosion-proof housing without display; configured for VAC power supply; enhanced EMI immunity (CE-compliant); CENELEC-compliant intrinsically safe sensor outputs; with three approved seal fittings 10 RFT9739 Transmitter

11 RFT9739 rack-mount model number matrix RFT9739 Transmitter Model RFT9739 transmitter R Housing options Rack-mount Power-supply options 1 110/115 VAC 2 220/230 VAC VDC E Configuration Enhanced EMI immunity (CE compliant) requires installation with Micro Motion cable type RFP or RFT installed in conduit, or type CBPS or CBPA installed with approved cable glands M U B Approvals Micro Motion standard (no approvals) UL CENELEC intrinsically safe sensor outputs F S Connector options Fast-on/solder terminals Y-shaped screw terminals Example* RFT9739 R 2 E B F *Example: RFT9739 R 2 E B F = RFT9739 rack-mount transmitter, configured for 220/230 VAC power supply; enhanced EMI immunity; CENELEC compliant; with fast-on/solder terminal connectors RFT9739 Transmitter 11

12 Due to Micro Motion's commitment to continuous improvement of our products, all specifications are subject to change without notice. Micro Motion, ELITE, and ProLink are registered trademarks of Micro Motion, Inc., Boulder, Colorado. Rosemount is a registered trademark of Rosemount, Inc., Eden Prairie, Minnesota. HART is a registered trademark of HART Communication Foundation, Austin, Texas. Modbus is a registered trademark of Modicon, Inc., North Andover, Massachusetts. For the latest Micro Motion product specifications, view the PRODUCTS section of our Web site at Micro Motion Europe Groeneveldselaan AZ Veenendaal The Netherlands Tel +31 (0) Fax +31 (0) Toll - free numbers (UK only) Tel Fax Rest of Europe Tel Fax , Micro Motion, Inc. All rights reserved PS EU (10/99)

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

Micro Motion Model RFT9739

Micro Motion Model RFT9739 Product Data Sheet PS-00024, Rev. A February 2004 Micro Motion Model RFT9739 Mass Flow and Density Transmitter TM Micro Motion Micro Motion Model RFT9739 transmitter Precise, multivariable measurement

More information

Micro Motion Model RFT9739 Flow and Density Transmitter

Micro Motion Model RFT9739 Flow and Density Transmitter Product Data Sheet PS-00024, Rev. B December 2007 Micro Motion Model RFT9739 Flow and Density Transmitter The Micro Motion Model RFT9739 transmitter works with Micro Motion sensors to provide precision

More information

Series 1000 and 2000 Transmitters with MVD TM Technology

Series 1000 and 2000 Transmitters with MVD TM Technology Series 1000 and 2000 Transmitters with MVD TM Technology Micro Motion Series 1000 and 2000 Transmitters with MVD Technology The new approach to sensor electronics Only Micro Motion combines new MVD Technology

More information

New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology. Product Data Sheet PS EU February 2001

New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology. Product Data Sheet PS EU February 2001 New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology Product Data Sheet PS-00408-EU February 2001 Contents Micro Motion CNG050 flowmeters..........3 Micro Motion Series 1000

More information

Mass Flow and Density Transmitter with FOUNDATION fieldbus

Mass Flow and Density Transmitter with FOUNDATION fieldbus Product Data Sheet Model 5300 PS-00352-GB Mass Flow and Density Transmitter with FOUNDATION fieldbus FOUNDATION FIELDBUS CAPABILITY Interoperable with other FOUNDATION fieldbus instruments Reduces wiring

More information

Model RFT9709 Transmitter Instruction Manual

Model RFT9709 Transmitter Instruction Manual Model RFT9709 Transmitter Instruction Manual March 1999 Model RFT9709 Transmitter Instruction Manual For technical assistance, phone the Micro Motion Customer Service Department: In the U.S.A., phone

More information

Micro Motion Series 1000 and 2000 Transmitters

Micro Motion Series 1000 and 2000 Transmitters Product Data Sheet PS-00400 June 2002 Micro Motion Series 1000 and 2000 Transmitters with MVD Technology! www.micromotion.com Micro Motion Series 1000 and 2000 Transmitters with MVD Technology The new

More information

Micro Motion Model 2400S Transmitters with MVD Technology

Micro Motion Model 2400S Transmitters with MVD Technology Product Data Sheet PS-00830, Rev. D March 2009 Micro Motion Model 2400S Transmitters with MVD Technology The Model 2400S transmitter provides next-generation MVD technology in a compact, space-saving design.

More information

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14

More information

Micro Motion Series 1000 and 2000 Transmitters

Micro Motion Series 1000 and 2000 Transmitters Product Data Sheet PS-00400, Rev. D October 2006 Micro Motion Series 1000 and 2000 Transmitters with MVD technology Advanced architecture with flexible installation options High-speed DSP Extensive built-in

More information

Micro Motion LF-Series Low Flow Sensor and Transmitter

Micro Motion LF-Series Low Flow Sensor and Transmitter Product Data Sheet PS-00566, Rev. D March 2007 Micro Motion LF-Series Low Flow Sensor and Transmitter with MVD technology Micro Motion LF-Series flowmeters Micro Motion LF-Series meters are the smallest

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

Micro Motion LF-Series Low Flow Flowmeter

Micro Motion LF-Series Low Flow Flowmeter Product Data Sheet PS-00566, Rev. C September 2005 Micro Motion LF-Series Low Flow Flowmeter With MVD Technology Micro Motion LF-Series flowmeters Micro Motion's LF-Series meters are the smallest Coriolis

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

ATEX Installation Drawings and Instructions

ATEX Installation Drawings and Instructions Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Micro Motion Series 1000 and Series 2000 Transmitters with MVD Technology

Micro Motion Series 1000 and Series 2000 Transmitters with MVD Technology Product Data Sheet PS-00400, Rev Q Micro Motion Series 1000 and Series 2000 Transmitters with MVD Technology Micro Motion Series 1000 and Series 2000 transmitters with MVD technology deliver powerful features

More information

Micro Motion Model 1500 Transmitter with the Filling and Dosing Application

Micro Motion Model 1500 Transmitter with the Filling and Dosing Application Product Data Sheet PS-00571, Rev. C January 2008 Micro Motion Model 1500 Transmitter with the Filling and Dosing Application Micro Motion's Model 1500 transmitter with the filling and dosing application

More information

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Installation Instructions P/N MMI-20011709, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Note: For hazardous installations in Europe, refer to standard EN

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol

I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol Product Specifications I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol PSS 1-2B7 A The Model CFT50 Digital Coriolis Mass Flow

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display

More information

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009. Product Data Sheet Magnetic Flowmeter Systems THE 8700 E-SERIES... Industry leading performance with standard reference accuracy of 0.25% of rate with an optional High Accuracy of 0.15% of rate. Rosemount

More information

SMART TEMPERATURE TRANSMITTERS. smar

SMART TEMPERATURE TRANSMITTERS. smar SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.

More information

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard

More information

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

Process display RIA 261

Process display RIA 261 Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

STT 3000 Smart Temperature Transmitter

STT 3000 Smart Temperature Transmitter STT 3000 Smart Temperature Transmitter Foundation TM Fieldbus Model STT35F Introduction EN0I-6083 April 2009 Specification and Model Selection Guide Honeywell s microprocessor based STT35F Smart Temperature

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

TIY Programmable, Isolated Thermocouple Transmitter combines

TIY Programmable, Isolated Thermocouple Transmitter combines April 2016 Description Moore Industries unique digital/analog hybrid the combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy and ease of use. Microprocessor-based,

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

Two-Wire Programmable Transmitter for:

Two-Wire Programmable Transmitter for: TM Smart Process Instrumentation Revision 2 Two-Wire Programmable Transmitter for: Industrial Thermocouple or RTD Temperature Measurements Highlights: Exceptional speed and accuracy Guaranteed measurement

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and

More information

Magnetic Flowmeter Systems

Magnetic Flowmeter Systems Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed

More information

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter Model 4081 ph/orp Product Data Sheet PDS 71-4081P February 2000 Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter REMOTE COMMUNICATION IS SIMPLE; use the hand-held infrared remote controller,

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Basic temperature transmitter offers a cost-effective solution for temperature monitoring points transmitter design provides flexible

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

Fisher 646 Electro-Pneumatic Transducers

Fisher 646 Electro-Pneumatic Transducers Product Bulletin D101374X012 646 Transducers Fisher 646 Electro-Pneumatic Transducers Fisher 646 electro-pneumatic transducers, shown in figure 1, use a patented converter module that converts a 4 to 20

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

Accutech FL10. Wireless float level field unit

Accutech FL10. Wireless float level field unit Accutech FL10 Wireless float level field unit 1 The Accutech FL10 wireless float level field unit interfaces with the Siemens TM Model 2100 and 1000 digital level sensors, providing single or dual fluid

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Kotron Model 82 CE RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art

More information

Applications: Power generation, Cogeneration, Stationary power Large engines

Applications: Power generation, Cogeneration, Stationary power Large engines Features: 8 inputs are user selectable from the following. 0-5V, 0-10V, 4-20 ma or 0-20 ma Digital inputs for interface to switches, etc. PWM signal, pulse or 16-bit counter inputs from sensors or diesel

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters Data Sheet Brooks Industrial Brooks Digital Series Digital MFC's and MFM's Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters General Features:

More information

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NA July 2004.

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NA July 2004. Magnetic Flowmeter Systems THE 8700 SERIES... Rosemount 8712D Transmitter - Easiest to use local operator interface and works with any manufacturer s flowtubes Rosemount 8712H/8707 High-Signal System -

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Alphaline Temperature Transmitters

Alphaline Temperature Transmitters Alphaline Temperature Transmitters Accepts RTD and thermocouple inputs Available with an integral meter Dual compartment housing provides the highest reliability in harsh industrial environments Offers

More information

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features GE Measurement & Control DigitalFlow XMT868i Panametrics Liquid Flow Ultrasonic Transmitter The DigitalFlow XMT868i liquid flow transmitter is a complete ultrasonic flow metering system for measurement

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

FDY PC-Programmable Frequency-to-DC Transmitter with Display

FDY PC-Programmable Frequency-to-DC Transmitter with Display PC-Programmable -to-dc March 2017 Description The PC-Programmable -to-dc monitors frequency, period, high or low pulse width, and contact closure signals. It converts the input signal to a proportional,

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics for INNOVATIVE SENSOR SOLUTIONS Standard & Custom Sensors, Signal Conditioners and Interface Electronics SPEED SENSORS Magnetic Speed Sensors (Active & Passive) Hall Effect Speed Sensors, GBR (Zero Speed)

More information

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS INSTALATION, OPERATION & MAINTENANCE MANUAL FOR PA-1001A Series SIGNAL CONDITIONER & CONVERTORS PA1001A 7/02 Page 1 of 11 SIGNAL CONDITIONER & CONVERTERS PA1001A Series INTRODUCTION: The PA1001A series

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter Features Include Base accuracy : ±0.075% Span limits 0.134 to

More information

Micro Motion Fork Viscosity Meters

Micro Motion Fork Viscosity Meters Product Data Sheet PS-001486, Rev B June 2014 Micro Motion Fork Viscosity Meters High performance multi-variable viscosity meter Rugged, accurate multi-variable measurement Continuous, multi-variable measurement

More information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

Series Smart Pressure Transmitter

Series Smart Pressure Transmitter www.tek-trol.com TEK-BAR 3100 Series Smart Pressure Transmitter www.tek-trol.com 2 Introduction The Tek-Bar series of smart transmitters have excellent stability, high accuracy and include features that

More information

Rosemount 702 Discrete Input Transmitter

Rosemount 702 Discrete Input Transmitter Product Data Sheet Rosemount 702 Rosemount 702 Discrete Input Transmitter An installation-ready solution that provides dual discrete inputs Single or dual switch input with logic for limit contact and

More information