PSK, PSS Series Data Sheet Positive Switching Regulators

Size: px
Start display at page:

Download "PSK, PSS Series Data Sheet Positive Switching Regulators"

Transcription

1 4.4" 3 U 4.4" 3 U " 2 TE " " 6 TE " Description The PSK/PSS Series of positive switching regulators is designed as power supplies for electronic systems, where no input-to-output isolation is required. Their major advantages include a high level of efficiency, high reliability, low output ripple, and excellenynamic response. Models with input voltages up to 44 V are specially designed for secondary switched and battery-driven mobile applications. The converters are suitable for railway applications according to EN 5055 and EN 502. Two type of housings are available allowing operation up to 7 C. They are designed for insertion into a 9" DIN-rack or for chassis mounting. Replacing the heat sink by an optional cooling plate, allows chassis or wall mounting on top of a metal surface, acting as heat sink. Various options are available to adapt the converter to different applications. Connector type: H5 or H5S4, depending on output current. Features RoHS lead-free-solder and lead-solder-exempted products are available Input voltage up to 44 VDC Single output of 3.3 to 48 VDC No input-to-output isolation High efficiency up to 97% Extremely wide input voltage range Low input-to-outpuifferential voltage Very good dynamic properties Input undervoltage lockout Active current sharing for parallel operation Output voltage adjustment, inhibit, and sense lines Continuously no-load and short-circuit proof All boards are coated with a protective lacquer Safety-approved to IEC/EN and UL/CSA nd Ed. Table of Contents Page Page Description... Model Selection... 2 Functional Description... 3 Electrical Input Data... 4 Electrical Output Data... 6 Auxiliary Functions... 0 Electromagnetic Compatibility (EMC)... 2 Immunity to Environmental Conditions... 4 Mechanical Data... 5 Safety and Installation Instructions... 8 Description of Options... 9 Accessories BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page of 20

2 Model Selection Table : All models Output Output Operating input Nom. input Efficiency 2 Type Connector Options voltage current voltage range voltage designation type V o nom [V] I o nom [A] V i [V] V i nom [V] η min [%] η typ [%] PSK3E25-7 H5S4 B, B PSS5A2-9 H5 B, B, G PSS5A4-2 4 H5 B, B PSK5A6-9 H5-7, E, P, C, B, B, G PSK5A8-2 4 H5 B, B PSK5A20-9 H5S4-7, E, P, C, K, B, B, G PSK5A25-9 H5S4-7, E, P, C, K, B, B, G PSS29-9 H5-7, E, B, B, G PSS22-9 H5 B, B, G PSK22-9 H5-7, E, P, C, B, B, G PSS H5 B, B PSK26-9 H5-7, E, P, C, B, B, G PSK28-2 H5 B, B PSK220-9 H5S4-7, E, P, C, K, B, B, G PSS29-9 H5-7, E, B, B, G PSS22-9 H5 B, B, G PSK22-9 H5-7, E, P, C, B, B, G PSS H5 B, B PSK26-9 H5-7, E, P, C, B, B, G PSK H5 B, B PSK220-9 H5S4-7, E, P, C, K, B, B, G PSS249-9 H5-7, E, P, C, B, B, G PSS242-9 H5-7, E, P, B, B, G PSK242-9 H5-7, E, P, C, B, B, G PSS H5 B, B PSK246-9 H5-7, E, P, C, B, B, G PSK H5 B, B PSK H5S4-7, E, P, C, K, B, B, G PSS369-9 H5-7, E, P, B, B, G PSS362-9 H5 B, B, G PSK362-9 H5-7, E, P, C, B, B, G PSK366-9 H5-7, E, P, C, B, B, G PSK H5S4-7, E, P, C, K, B, B, G PSS489-9 H5 B, B PSK482-9 H5-7, E, P, C, B, B, G Surges up to 56 V for 2 s; see Electrical Input Data 2 Efficiency at V i nom and I o nom. Models with opt. K (standard H5 connector) exhibit approx. to 2% lower efficiency. 3 Output voltage V o set to 5 V by R input 4 Use other PSK/PSS models with same case size (PSK or PSS) and same connector (H5 or H5S4). Note: Non-standard input/output configurations or special custom adaptions are available on request. NFND: Not for new designs Preferred for new designs BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 2 of 20

3 Part Number Description Positive switching regulator in case S0, K0... PSS, PSK Nominal output voltage in Volt Nominal output current in Ampere PSK E P C B G Operational ambient temperature range T A 0 to 50 C to 7 C to 7 C (optional) Options: Inrush current limitation... E Potentiometer to adjust V o... P Thyristor crowbar... C Standard H5 connector... K Cooling plate large/small... B, B RoHS-compliant for all 6 substances... G 2 Option P excludes R-features and vice versa. 2 G is always placed at the end of the part number. Example: PSS29-9EPCB = Positive switching regulator with output 2 V, 9 A, ambient temperature range of 25 to 7 C, inrush current limitation, potentiometer, crowbar, and large cooling plate option B. Note: The sequence of options must follow the order above. allocation, identification of LED, test sockets, and optional potentiometer. Product Marking Label with input voltage range, output voltage and current, Type designation, applicable approvals marks, warnings, pin protection degree, batch and serial no., and data code including production site, version, and date of production. Functional Description The switching regulators are using the buck topology. The input is not electrically isolated from the output. During the on period of the switching FET, current is transferred to the output, and energy is stored in the output choke. During the off period, this energy forces the current to continue flowing through the output choke and the freewheeling diode to the load. Regulation is accomplished by varying on/off duty cycle. Switching frequency is approx. 00 khz. The converters exhibit an undervoltage monitor to prevent high currents at low input voltage, but no overvoltage monitor. These regulators are ideal for applications, where an input to output isolation is not necessary or where it is already provided by an external front end, e.g. a transformer with rectifier. To optimize customer s needs, various options and accessories are available. V i I i Vi+ Gi Fig. Block diagram Fuse Option E Input Filter C i Option C Control circuit Option P BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 3 of 20 C o a 4 6 Vo+ 20 S+ 22 T 4 i 6 R 8 S 8 0 Go I o V o

4 Electrical Input Data Table 2a: Inpuata. General Conditions: T A = 25 C, unless T C is specified Input PSS5A4 PSS24 PSS244 Unit PSK5A8 PSK28 PSK248 Characteristics Conditions min typ max min typ max min typ max V i Operating input voltage I o = 0 I o nom / VDC V io min Min. diff. voltage V i V o T C min T C max 2.9 3/4 5 V i o Undervoltage lockout I i 0 No load input current I o = 0, V i min V i max ma I inr p Peak value of inrush current V i nom, with option E A C x Input capacitance µf The second value is valid, if output is set to 5 V with the R-input. Table 2b: Inpuata. General Conditions: T A = 25 C, unless T C is specified Input PSK3E25 PSS5A2 PSS22 Unit PSK5A25 PSK5A6 PSK26 PSK5A20 PSK220 Characteristics Conditions min typ max min typ max min typ max V i Operating input voltage I o = 0 I o nom VDC V io min Min. diff. voltage V i V o T C min T C max 4.7/ V i o Undervoltage lock-out I i 0 No load input current I o = 0, V i min V i max ma I inr p Peak value of inrush current V i nom, with option E A C x Input capacitance µf Values for PSK3E25/PSK5A20 Table 2c: Inpuata. General Conditions: T A = 25 C, unless T C is specified Input PSS22 PSS242 PSS362 Unit PSK26 PSK246 PSK366 PSK220 PSK2420 PSK3620 Characteristics Conditions min typ max min typ max min typ max V i Operating input voltage I o = 0 I o nom VDC V io min Min. diff. voltage V i V o T C min T C max V i o Undervoltage lock-out I i 0 No load input current I o = 0, V i min V i max ma I inr p Peak value of inrush current V i nom, with option E A C x Input capacitance µf Output set to 5 V with the R-input. BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 4 of 20

5 Table 2d: Inpuata. General Conditions: T A = 25 C, unless T C is specified Input PSS29 PSS29 PSS249 Unit PSK22 PSK22 PSK242 Characteristics Conditions min typ max min typ max min typ max V i Operating input voltage I o = 0 I o nom VDC V io min Min. diff. voltage V i V o T C min T C max V i o Undervoltage lock-out I i 0 No load input current I o = 0, V i min V i max ma I inr p Peak value of inrush current V i nom, with option E A C x Input capacitance µf Output set to 5 V with the R-input. 2 Surges up to 56 V for 2 s are allowed (no shutdown). Table 2e: Inpuata. General Conditions: T A = 25 C, unless T C is specified Input PSS369 PSS488 Unit PSK362 PSK482 Characteristics Conditions min typ max min typ max V i Operating input voltage I o = 0 I o nom VDC V io min Min. diff. voltage V i V o T C min T C max 8 0 V i o Undervoltage lock-out I i 0 No load input current I o = 0, V i min V i max ma I inr p Peak value of inrush current V i nom, with option E 6 6 A C x Input capacitance µf Surges up to 56 V for 2 s are allowed (no shutdown). Input Filter and Fuse An input filter and a fuse are incorporated in all converters as standard. The filter reduces emitted electrical noise and prevents oscillations caused by the negative input impedance frequency f i has the following values: v i max = 000 Hz /f i V (or 0 V pp at 00 Hz) Inrush Current Table 3: Input fuses Model Fuse type Size Supplier PSK3E25, PSK5A20, PSK5A25 F 25 A mm Littlefuse PSK220, PSK2420, PSK3620 PSK5A6, PSK26, PSK28 F 20 A PSK246, PSK248, PSK3620 PSS5A2, PSS5A4, F 5 A PSS22, PSK22, PSS24 PSS242, PSK242, PSS244 PSS362, PSK362, PSK366 PSK482 PSS29, PSS249 F 0 A PSS369, PSS489 characteristic of a switched mode regulator. The input fuse protects against fatal defects; see table 3. The maximum permissible additionally superimposed ripple v i of the input voltage (rectifier mode) at a specified input BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 5 of 20 + R ext V i source I inr p Fig. 2 Equivalent input circuit R i C X + JM085a Vo+ Vo Depending on the input source and the input impedance, the inrush current into the converter may reach a high peak value during the switch-on. The inrush current peak value can be determined by following calculation; see also fig. 2: V i source I inr p = (R s ext + R i ) To limit the inrush current, we recommend the choice of the active inrush current limitation circuit, option E. Load

6 Electrical Output Data General Conditions: T A = 25 C, unless T C is specified R control (pin 6) not connected or progammed to V o nom at I o nom Inhibit input (pin 4) connected to Go Sense lines S+ and S connected at female connector Table 3a: Outpuata of PSS models Output PSS5A2 PSS22 PSS22 Unit Characteristics Conditions min typ max min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage IEC/EN 6204 Total incl. spikes noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load I Recovery time o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ± ±3 ±4 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 ±0.02 %/K Output set to 5 V with R-input. Table 3b: Outpuata of PSS models. General conditions as per table 3a Output PSS242 PSS244 PSS362 Unit Characteristics Conditions min typ max min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage IEC/EN 6204 Total incl. spikes noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load I Recovery time o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ±5 ±5 ±8 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 ±0.02 %/K BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 6 of 20

7 Table 3c: Outpuata of PSS models. General conditions as per table 3a Output PSS29 PSS29 PSS249 Unit Characteristics Conditions min typ max min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage IEC/EN 6204 Total incl. spikes noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load I Recovery time o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ±3 ±4 ±5 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 ±0.02 %/K Output set to 5 V with R-input. Table 3d: Outpuata of PSS models. General conditions as per table 3a Output PSS369 PSS489 Unit Characteristics Conditions min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage IEC/EN 6204 Total incl. spikes noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load I Recovery time o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ±5 ±0 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 %/K Table 4a: Outpuata of PSK models. General conditions as per table 3a Output PSK3E25 PSK5A6 PSK5A20 PSK5A25 Unit Characteristics Conditions min typ max min typ max min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage Total incl. spikes IEC/EN 6204 noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load Recovery time I o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ± ± ± ± mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 ±0.02 ±0.02 %/K BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 7 of 20

8 Table 4b: Outpuata of PSK models. General conditions as per table 3a Output PSK26 PSK220 PSK26 PSK220 Unit Characteristics Conditions min typ max min typ max min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage Total incl. spikes IEC/EN 6204 noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load Recovery time I o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ±3 ±3 ±4 ±4 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 ±0.02 ±0.02 %/K Output set to 5 V with R-input. Table 4c: Outpuata of PSK models. General conditions as per table 3a Output PSK246 PSK2420 PSK366 PSK3620 Unit Characteristics Conditions min typ max min typ max min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage Total incl. spikes IEC/EN 6204 noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load Recovery time I o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ±5 ±5 ±8 ±8 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 ±0.02 ±0.02 %/K Table 4d: Outpuata of PSK models. General conditions as per table 3a Output PSK22 PSK22 PSK242 Unit Characteristics Conditions min typ max min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage IEC/EN 6204 Total incl. spikes noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load I Recovery time o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ±3 ±4 ±5 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 ±0.02 %/K Output set to 5 V with R-input BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 8 of 20

9 Table 4e: Outpuata of PSK models. General conditions as per table 3a Output PSK362 PSK482 Unit Characteristics Conditions min typ max min typ max V o Output voltage V i nom, I o nom V I o Output current V i min V i max A I ol Output current limit T C min T C max v o Output Switching freq. V i nom, I o nom mv pp voltage IEC/EN 6204 Total incl. spikes noise BW = 20 MHz V o V Static line regulation V i min V i max, I o nom mv V o l Static load regulation V i nom, I o = 0 I o nom v o d Dynamic Voltage deviat. V i nom load I Recovery time o nom /3 I o nom regulation IEC/EN µs α Vo Temperature coefficient V i min V i max ±5 ±0 mv/k V o / T C (T C min to T C max ) I o = 0 I o nom ±0.02 ±0.02 %/K Output Voltage Regulation The dynamic load regulation is shown in fig. 2 V o /V o nom 05038a V o I o /I o nom V od V o ±% V o ±% V od 0 µs 0 µs Fig. 3 Dynamic load regulation. 0502c Output Protection A voltage suppressor diode, which in worst case conditions fails into a short-circuit, protects the output against an internally generated overvoltage. Such an overvoltage could occur due to a failure of either the control circuit or the switching transistor. The output protection is noesigned to withstand externally applied overvoltages. t t Fig. 4 Overload, short-circuit behaviour V o versus I o. Parallel and Series Connection I o L I o /I o nom Outputs of equal nominal voltage may be parallel-connected. Interconnect the current sharing pins T (pin 22) for even distribution of the output current; see Auxiliary Functions. Outputs can be series-connected with any other regulator, provided that the regulators are powered by electrically isolated source voltages. In series connection the maximum output current is limited by the lowest current limitation. Current Limitation A constant current limitation circuit holds the output current I o almost constant in the area of 00 to 20% of I o nom, when an overload or a short-circuit is applied to the output. It acts selfprotecting and recovers in contrary to the fold back method automatically after removal of the overload or short-circuit condition. BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 9 of 20

10 Thermal Considerations and Protection When a switching regulator is located in free, quasi-stationary air (convection cooling) at a temperature T A max and is operated at its nominal output current I o nom, the case temperature T C can rise over T C max after the warm-up phase. T C is measured at the measuring point of case temperature; see Mechanical Data. Under practical operating conditions, the ambient temperature T A may exceed T A max, provided that additional measures (heat I o /I o nom T A min convection cooling 05032a forced cooling C T C max Fig. 5a Output currenerating versus temperature (models -2) T A sink, forced cooling, etc.) are taken to ensure that the case temperature T C does not exceed its maximum value. The regulater is protected by an internal temperature sensor, which inhibits the output above T C max. The output automatically recovers, when the temperature drops below T C max. I o /I o nom T A min convection cooling 0503a forced cooling C T C max Fig. 5b Output currenerating versus temp. (models -7 or -9) T A Auxiliary Functions I inh [ma] Inhibit (Remote On / Off) The inhibit input allows to enable or disable the output with a control signal. In systems with several regulations, this feature can be used to control the activation sequence of the Table 5: Inhibit characteristics Characteristics Conditions min typ max Unit V inh Inhibit input voltage V o = on V i min V i max V V o = off T C min T C max t r Switch-on time V i = V i nom 30 ms t f Switch-off time R L = V o nom /I o nom 25 I i inh Input current when inhibited V i = V i nom 25 ma Vi+ Gi 06009a Vo+ i Go I inh V inh Fig. 6 Specification of the inhibit signal (typical) BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 0 of Output on V inh = 0.8 V V inh = 2.4 V 06034a Output off V Fig. 7 Specification of the inhibit signal (typical) V o /V o nom 0. 0 t t r t f Inhibit Fig. 8 Output response as a function of the inhibit signal t V inh

11 regulators by a logic signal (TTL, C-MOS, etc.). An output voltage overshoot will not occur, when switching on or off. The inhibit signal is referenced to the S (pin 8). The signal i and the switching times are specified in table 5, fig. 6 to 8. Note: With open i input, the output is enabled. Sense Lines This feature enables compensation of the voltage drop across the connector contacts and the load lines. If the sense lines are connected at the load rather than directly at the connector, the user must ensure that V o max (between Vo+ and Go ) is not exceeded. Applying generously dimensioned cross-section load leads reduces the voltage drop. To minimize noise pick-up, the sense lines should be wired in parallel or twisted. To ensure correct operation, both sense lines must be connected to their respective power output. The voltage difference between any sense line and its respective power output pin (as measured on the connector) should not exceed the values given in table 6. Note: Sense lines should always be connected! It is recommended to connect the sense lines directly at the female connector. Table 6: Allowed voltage compensation using sense lines Nominal output Total voltage difference Voltage difference voltage between both sense lines between and their respective output Go and S 3.3 V, 5. V 0.5 V 0.25 V 2 48 V.0 V 0.25 V Vi+ Gi V ref = 2.5 V Fig. 0 Voltage adjustment via R-input + 4 kω Control logic JM54 R Control (Output Voltage Adjust) Note: With open R input, V o V o nom. The output voltage V o can either be adjusted with an external voltage source (V ext ) or with an external resistor (R ext or R ext2 ). The adjustment range is approx. 0 V o max. The minimum differential voltage V io min between input and output (see Electrical Input Data) should be maintained. a) V o = 0 V o max, using V ext between R and S : V o V ext V ext 2.5 V V o V o nom V o nom 2.5 V Caution: To prevenamage V ext should not exceed 20 V, nor be negative. b) V o = 0 to V o nom, using R ext between R and S : 4000 Ω V o V o nom R ext R V o V o nom V o R Ω S+ R S Go R ext2 R ext + V ext Vi+ i R T Gi 06046a Vo+ S+ S Go Load c) V o = V o nom to V o max, using R ext2 between R and S+: 4000 Ω V o (V o nom 2.5 V) R V (Vo Vo nom) V o nom 2.5 V R ext2 V o 2.5 V (R Ω) V o nom 4000 Ω Caution: R ext should never be less than 47 kω. Fig. 9 Sense lines connection Current Sharing For parallel operation of several regulators, interconnect all T- pins to ensure that the output currents are evenly distributed. This feature improves transient load performance and increases system reliability. All paralleled regulators should be supplied by equal input voltage (V i ). The output lines should exhibit equal length and cross section to provide equal voltage drop. Test Sockets Test sockets (pin = 2 mm) for measuring the output voltage V o at the sense lines, are located at the front side of the regulator. The test sockets are protected by a series resistor. LED Output Voltage Indicator A green LED indicator shines when the output voltage is present. Table 7: Maximum adjustable output voltage V o nom Nominal Output Volt. Conditions 3.3 V 5. V 2/5 V 24 V 36 V 48 V Unit min typ min typ min typ min typ min typ min typ V o max Maximum adjustable V i nom, I o nom V output voltage with R-input BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page of 20

12 Electromagnetic Compatibility (EMC) Electromagnetic Immunity General condition: Case not earthed. Table 8: Immunity type tests Phenomenon Standard Class Coupling Value Waveform Source Test In Perf.- Level mode applied imped. procedure oper. crit. 4 Direct transients 2 IEC i/c, +i/ i 800 V p 00 µs 00 Ω pos. and neg. yes B 500 V p 50 µs voltage surge per coupling mode 3000 V p 5 µs 4000 V p µs 7000 V p 00 ns Electrostatic IEC/EN 4 2 contacischarge 8000 V p /50 ns 330 Ω 0 positive and yes A discharge negative air discharge 5000 V p (to case) discharges Electromagnetic IEC/EN 3 2 antenna 0 V/m 2 AM 80% MHz yes A field V/m 3 khz 3 2 antenna 0 V/m 50% duty cycle, n.a. 900 ±5 MHz yes A 200 Hz rep. rate Electrical fast IEC/EN 3 2 i/c, +i/ i 2000 V 2 p bursts of 5/50 ns 50 Ω 60 s positive yes A transients/burst V 3 p 5 khz rep. rate 60 s negative V 2 transients with transients per p V 3 5 ms burst coupling mode p duration and 300 ms period Surges IEC/EN 3 2 i/c 2000 V 2 p.2/50 µs 2 Ω 5 pos. and 5 neg. yes A V 3 p surges per 3 2 +i/ i 2000 V 2 p.2/50 µs 2 Ω coupling mode V 3 p Conducted IEC/EN 3 2 i, o, signal wires 0 VAC 2 AM 80% 50 Ω MHz yes A disturbances VAC 3 khz i = input, o = output, c = case 2 Not applicable for -2 models 3 Valid for -2 models 4 A = Normal operation, no deviation from specifications, B = Normal operation, temporary loss of function or deviation from specs possible 5 With option C, manual reset might be necessary. B 5 BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 2 of 20

13 Electromagnetic Emissions dbµv 80 Limit: 6204bqp Detector: Peak, conducted Vi+, EMC-Service Divina, PSK242-9, U i = 0 Vdc, U o = 24 V, I o = 0 A JM53 EN A qp dbµv/m EMC-Service Divina, ESVS 30:R&S, BBA 906/UHALP 907:Schwarzb., QP, Testdistance 0 m, PSK24Z0A-7EC U i =66 V, U o =24 V I o = 0 A EN 550 A JM52 60 EN A pk MHz MHz Fig. Typical conducted disturbance voltage (quasi-peak and avrage) according to EN 550/22 measured at V i nom = 0 V and I o = 0 A (PSK242-9). Fig. 2 Typ. radiated disturbance voltage (quasi-peak) in 0 m distance according to EN 550/22 measured at V i nom = 0 V and I o = 0 A (PSK242-9). BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 3 of 20

14 Immunity to Environmental Conditions Table 9: Mechanical and climatic stress Test Method Standard Test Conditions Status Cab Damp heat IEC/EN Temperature: 40 ±2 C Regulator steady state MIL-STD-80D section Relative humidity: 93 +2/-3 % not Duration: 56 days operating Db Damp heat test, EN 5055:2007, clause Temperature: 55 C and 25 C Converter cyclic 2 IEC/EN Cycles (respiration effect): 2 not Duration: 2 24 h operating -- Salt mist test EN 5055:2007 Temperature: 35 ±2 C Regulator sodium chloride sect Duration: 6 h not (NaCl) solution class ST2 operating Ea Shock IEC/EN Acceleration amplitude: 50 g n = 490 m/s 2 Regulator (half-sinusoidal) MIL-STD-80D section 56.3 Bump duration: ms operating Number of bumps: 8 (3 each direction) Eb Bump IEC/EN Acceleration amplitude: 25 g n = 245 m/s 2 Regulator (half-sinusoidal) MIL-STD-80D section 56.3 Bump duration: ms operating Number of bumps: 6000 (000 each direction) Fc Vibration IEC/EN Acceleration amplitude: 0.35 mm (0 60 Hz) Regulator (sinusoidal) MIL-STD-80D section g n = 49 m/s 2 ( Hz) operating Frequency ( Oct/min): Hz Tesuration: 7.5 h (2.5 h each axis) Fda Random vibration IEC/EN Acceleration spectral density: 0.05 g 2 /Hz Regulator wide band DIN part 23 Frequency band: Hz operating Reproducibility Acceleration magnitude: 4.9 g n rms high Tesuration: 3 h ( h each axis) -- Shock EN 5055:2007 clause 2.2. Acceleration amplitude: 5. g n Regulator EN 6373 sect. 0, Bump duration: 30 ms operating class B, body mounted Number of bumps: 8 (3 in each direction) -- Simulated long life EN 5055:2007 clause 2.2. Acceleration spectral density: 0.02 g 2 n /Hz Regulator testing at EN 6373 sect. 8 and 9, Frequency band: 5 50 Hz operating increased random class B, body mounted Acceleration magnitude: 0.8 g n rms vibration levels Tesuration: 5 h (5 h in each axis) Body mounted = chassis of a railway coach 2 Models with version V04 or later Temperatures Table 0: Temperature specifications, valid for an air pressure of hpa ( mbar) Temperature -2-7 (Option) -9 Characteristics Conditions min max min max min max Unit T A Ambient temperature Regulator C T C Case temperature operating T S Storage temperature Non operational See Thermal Considerations and Overtemperature Protection. Reliability Table : MTBF and device hours MTBF Ground Benign Ground Fixed Ground Mobile Device Hours MTBF acc. to MIL-HDBK-27F T C = 40 C T C = 40 C T C = 70 C T C = 50 C h h h h h Statistical values, based on an average of 4300 working hours per year and in general field use BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 4 of 20

15 Mechanical Data PSS Models The regulators are designed to be inserted into a rack according to IEC Dimensions in mm. European Projection 7 TE 5 TE to b 4 x M4 LED OK green ± Potentiometer (option P) + Test sockets Measuring point of case temperature T C Front plate Main face 68.5 ±0.5 Back plate 60 d x Screw holes of the frontplate Fig. 3 Case S0 for PSS models; weight.3 kg Aluminum, fully enclosed, black finish EP power-coated, and self cooling. Notes: d 5 mm, recommended minimum distance to next part to ensure proper air circulation at full output power. Free air locations: the regulator should be mounted with its fins in vertical position to achieve a maximum air flow through heat sink. BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 5 of 20

16 PSK Models The regulators are designed to be inserted into a DIN-rack according to IEC Dimensions in mm. European Projection TE 9 TE b LED OK green 89 ± Potentiometer (option P) + Test sockets Measuring point of case temperature T C to Front plate Main face Back plate 68.5 d.8 5 x Screw holes of the frontplate Fig. 4 Case K0 for PSK models, weight.6 kg Aluminum, fully enclosed, black finish EP powder-coated, and self cooling. Notes: d 5 mm, recommended minimum distance to next part to ensure proper air circulation at full output power. Free air locations: the regulator should be mounted with its fins in vertical position to achieve a maximum air flow through heat sink. BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 6 of 20

17 Option B, B European Projection ± Fig. 5 Option B, large cooling plate Weight:.3 kg M ± Fig. 6 Option B, small cooling plate Weight:.2 kg BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 7 of 20

18 Safety and Installation Instructions Connector Pin Allocation The connector pin allocation table defines the electrical potentials and the physical pin positions on the H5 or H5S4 connector. Pin 24 (protective earth) is a leading pin, which provides electrical contact first. The regulators should only be wired via the female connector H5 (according to DIN 462) to ensure requested safety! 32 30/32 Fixtures for connector retention clips V (see Accessories) Type H5 Fixtures for connector retention clips V (see Accessories) Type H5S4 Fig. 7 View of H5 and H5S4 male connector 000a 4 4/6 Installation Instruction Installation of the regulators must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, clearance, casualty, markings, and segregation requirements of the end-use application. The input and the output circuit are not separated. The negative path is internally interconnected. The regulators should be connected to a secondary circuit. Make sure that a regulator failure (e.g. by an internal shortcircuit) does not result in a hazardous condition. Do not open the regulator! Standards and Approvals The regulators are safety-approved to UL/CSA nd Ed. and IEC/EN nd Ed. They correspond to Class I equipment (with case connected to ground). The regulators have been evaluated for: Building in No insulation from input to output. The use in a pollution degree 2 environment Connecting the input to a secondary circuit, which is subject to a maximum transient rating of 500 V. The switching regulators are subject to manufacturing surveillance in accordance with the above mentioned standards and with ISO 900:2008. Cleaning Liquids In order to avoid possible damage, any penetration of cleaning fluids must be prevented, since the regulators are not hermetically sealed. Table 2: H5 and H5S4 connector pin allocation Electrical Determination Type H5 Type H5S4 Pin no. Ident. Pin no. Ident. Output voltage (positive) 4 Vo+ Output voltage (positive) 6 Vo+ 4/6 Vo+ Output voltage (negative) 8 Go Output voltage (negative) 0 Go 8/0 Go Crowbar trigger input (option C) 2 C 2 C Inhibit input 4 i 4 i R-input (output voltage programming) 6 R 6 R Sense line (negative) 8 S 8 S Sense line (positive) 20 S+ 20 S+ Current sharing control input 22 T 22 T Protective ground (leading pin) Input voltage (negative) 26 Gi Input voltage (negative) 28 Gi 26/28 Gi Input voltage (positive) 30 Vi+ Input voltage (positive) 32 Vi+ 30/32 Vi+ Not connected with option P Protection Degree The protection degree is IP 30 (IP 20, if equipped with option P). It applies only, if the regulator is plugged-in or the matching female connector is properly attached. Isolation and Protective Earth The resistance of the protective earth connection (max. 0. Ω) is tested. The electric strength between input interconnected with output and case is tested with 500 VDC s (all models with version V03 or later). Models with V i max = 44 V and V04 or later are tested with 2200 VDC s. These tests are performed in the factory as routine test in accordance with EN 506 and IEC/EN The electric strength test should not be repeated by the customer. BelPS Company does not honor warranty claims resulting from incorrect electric strength tests. Railway Application The regulators have been developed observing the railway standards EN 5055 and EN 502. All boards are coated with a protective lacquer. BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 8 of 20

19 Description of Options Î [A] 029a -7 Temperature Range This option defines a restricted temperature range as specified in table 0 (not for new designs). Inrush limit V (I i = ) i R s Soft start Normal operation (R s bypassed) P Potentiometer to Adjust the Output Note: Option P is not recommended for regulators operated in parallel connection. Option P excludes the R function; the R-input (pin 6) should be left open-circuit. The output voltage V o can be adjusted in the range 90 0% of V o nom. However, the minimum differential voltage V i max between input and output as specified in Electrical Input Data should be respected. E Inrush Current Limitation Note: This option requires an increased minimum input voltage V i max of up to V, dependent upon input range. In regulators without option E, after application of the input supply the inrush current is limited by parasitic components of the voltage source and the regulator input only. The regulator input exhibits a very low impedance, and when driven from a low impedance source, for example a battery, the inrush current can peak at several orders of magnitude above the continuous input current. Option E dramatically reduces this peak current and is recommended for any application to protect series elements such as fuses, switches, or circuit brakers. The start-up circuit is bypassed during normal operation. C Thyristor Crowbar Note: The crowbar can be reset by removal of the input voltage only. The inhibit signal cannoeactivate the thyristor. Option C protects the load against power supply malfunction. It is noesigned to sink external currents. As a central overvoltage protection device, the crowbar is usually connected to the external load via distributed inductance of the lines. For this reason, the overvoltage at the load can temporarily exceed the trigger voltage V o c. Depending on the application, further decentralized overvoltage protection elements may have to be used additionally. Fig. 8 Option E: Inrush current versus time. R s is the startup resistor (R s = Ω for models with V i max 80 V, R s = 5 Ω for models with V i max > 80 V) A fixed-value monitoring circuit checks the output voltage V o, and when the trigger voltage V o c is reached, the thyristor crowbar triggers and disables the output. An external connection C (crowbar trigger control) is provided. When crowbar option is used with two or more power supplies in parallel connection, all crowbar trigger terminals (C) should be interconnected. This ensures all crowbar circuits triggering simultaneously, in order to disable all outputs at once. The crowbar trigger voltage is maintained between Vo+ and Go. To prevent false triggering, the user should ensure that V o (between Vo+ and Go ) deos not exceed V o c. B, B Cooling Plate Where a cooling surface is available, a cooling plate (option B or option B) can be fitted instead of the standard heatsink. The mounting system must ensure sufficient cooling capacity to guarantee that the maximum case temperature T C max is not exceeded. The required cooling capacity can be calculated by the following formula: 00% η P Loss = - (V o I o ) η G t 0 40 (typical) 00 (typical) ms RoHS Compliance Models with G are RoHS-compliant for all six substances. Table 3: Crowbar trigger levels Characteristics Conditions PSK5A6 PSK22 PSS249 PSK362 PSK482 Unit PSK5A20 PSK26 PSK242 PSK366 PSK5A25 PSK220 PSK246 PSK3620 PSK2420 min typ max min typ max min typ max min typ max min typ max V o c Trigger voltage T C min T C max V V i min V i max Delay time I o = 0 I o nom µs t s Models with option P BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 9 of 20

20 Accessories A variety of electrical and mechanical accessories are available including: Various front panels for 9" DIN-racks with 3U heigth, 2 or 6 TE, Schroff or Intermas Various mating connectors H5 and H5S4 including faston, screw, solder, or press-fit terminals, code key system and coding wedges HZZ00202-G Pair of connector retention clips HZZ0209-G; see fig. 20 Connector retention brackets HZZ026-G; see fig. 22 Different cable connector housings (cable hoods), including a metallic version for fire protection Cage clamp adapter HZZ0044-G; see fig. 23 Wall-mounting plate K02 HZZ023, only for models with option B Brackets for DIN-rail and wall mounting HZZ0060 DIN-rail mounting assembly HZZ065-G; see fig. 24 Battery sensors S-KSMH... for using the converter as battery charger. Different cell characteristics can be selected; see Battery Charging/ Temperature Sensor. For additional accessory product information, see the accessory data sheet listed with each product series or individual model listing at our web site. 20 to 30 Ncm Fig. 22 Connector retention brackets HZZ026-G Fig. 23 Cage clamp adapter HZZ0044-G Fig. 9 H5 female connector with code key system Fig. 20 Connector retention clips HZZ0209-G Fig. 2 Different front panels Fig. 24 DIN-rail mounting assembly HZZ065-G NUCLEAR AND MEDICAL APPLICATIONS - These products are noesigned or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. BCD20029-G Rev AC, 2-Jan-205 The Power Partners. Page 20 of 20

PSB Series Data Sheet Positive Switching Regulators

PSB Series Data Sheet Positive Switching Regulators 69 2.7" 6 4.2" 32.3" Features RoHS lead-free-solder and lead-solder-exempted products are available 5 year warranty for RoHS compliant products with an extended temperature range Compliant to EN 45545

More information

PSB Series Data Sheet Positive Switching Regulators

PSB Series Data Sheet Positive Switching Regulators Features Input voltage up to 44 VDC Single output of 5. to 48 VDC No input-to-output isolation High efficiency up to 96% Extremely wide input voltage range Low input-to-output differential voltage Very

More information

PSA/PSR Series Data Sheet Positive Switching Regulators

PSA/PSR Series Data Sheet Positive Switching Regulators Features RoHS lead-free-solder and lead-solder-exempted products are available Input voltage up to 44 VDC Single output 5 to 48 V No input-to-output isolation High efficiency up to 95% Extremely wide input

More information

PSC, PSL Series Data Sheet Positive Switching Regulators

PSC, PSL Series Data Sheet Positive Switching Regulators 07 4." 3U 3.3" 88 3.5" 5 5.9" 37.5" 8 TE 68 6.6" Features Input voltage up to 44 VDC Single output of 3.3 to 48 VDC No input-to-output isolation Description High efficiency up to 97% The PSC and PSL Series

More information

PSA/PSR Series Data Sheet Positive Switching Regulators

PSA/PSR Series Data Sheet Positive Switching Regulators Features RoHS lead-free-solder and lead-solder-exempted products are available Compliant to EN 45545 (version V04 or later) Input voltage up to 44 VDC Single output 5 to 48 V No input-to-output isolation

More information

PSA/PSR Series Positive Switching Regulator

PSA/PSR Series Positive Switching Regulator The PSA/PSR Series of positive switching regulators are designed as power supplies for electronic systems when no input-to-output isolation is required. Their major advantages include a high level of efficiency,

More information

PSC, PSL Series Data Sheet Positive Switching Regulators

PSC, PSL Series Data Sheet Positive Switching Regulators 88 3.5" 5 5.9" 32.3" 37.5" 8 TE 68 6.6" 7 4.2" 3 U Description The PSC and PSL Series positive switching regulators are designed as power supplies for electronic systems, where no input-to-output isolation

More information

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters Features RoHS lead-free-solder and lead-solder-exempted products are available Rugged 5 mm DIN-rail snap-fit design Class I equipment Universal AC-input with single stage conversion AC to DC or DC input

More information

Features " 3 U. Preliminary. Copyright 2016, Bel Power Solutions Inc. All rights reserved.

Features  3 U. Preliminary. Copyright 2016, Bel Power Solutions Inc. All rights reserved. Features RoHS-compliant Class I equipment Universal input voltage range Inrush current limitation 2 isolated adjustable outputs No load, overload, and short-circuit proof Rectangular current limiting characteristic

More information

RCM Series Data Sheet 150 /300 W DC-DC Converters

RCM Series Data Sheet 150 /300 W DC-DC Converters Description The RCM Series converters are reliable power supplies for railway and transportation systems. There are 2 input voltage ranges covering all common railway batteries. The output delivers 15

More information

LR Series Watt AC-DC and DC-DC Converters

LR Series Watt AC-DC and DC-DC Converters The LR Series of AC-DC converters represents versatile power supplies ideally suitable for use in advanced electronic systems. Features include full power factor correction, good hold-up time, high efficiency

More information

IMX4 Series Data Sheet 4 Watt DC-DC Converters

IMX4 Series Data Sheet 4 Watt DC-DC Converters 0 0.8" 8.5 0.34" 3 1.5" Features RoHS lead-free-solder and lead-solder-exempted products are available. Input voltage ranges up to 11 VDC Voltage withstand test 1500 VAC 1 or isolated outputs up to 48

More information

IMX4 Series Data Sheet 4 Watt DC-DC Converters

IMX4 Series Data Sheet 4 Watt DC-DC Converters 0 0.8" 8.5 0.34" 3.5" Features RoHS lead-free-solder and lead-solder-exempted products are available. Input voltage ranges up to VDC or isolated outputs up to 48 V Extremely wide input voltage ranges Immunity

More information

P Series Data Sheet Watt DC-DC Converters

P Series Data Sheet Watt DC-DC Converters Features RoHS lead-free-solder and lead-solder-exempted products available Wide input voltage ranges up to 154 VDC 1, 2, 3 or 4 isolated outputs up to 96 V Class I equipment Compliant with EN 45545 and

More information

IMX35 Series Data Sheet 35 Watt Quad-Output DC-DC Converters

IMX35 Series Data Sheet 35 Watt Quad-Output DC-DC Converters 63.5 2.5" 47.8 1.88" 76.2 3" 10.5 0.41" 8.9 0.35" 72.8 2.87" Features Extremely wide input voltage ranges up to 150 VDC 4 outputs up to 60 V RoHS lead-free-solder and lead-solder-exempted products available.

More information

LRS Series Data Sheet AC-DC Subrack Systems MK007

LRS Series Data Sheet AC-DC Subrack Systems MK007 Features Compliant to AREMA, EN 5055, and EN 50-4 RoHS-compliant for all 6 substances 9-inch DIN-rack system, convection cooling Different output configurations Extremly rugged, reliable design for harsh

More information

IMX15, IMY15, IMS15 Series Data Sheet 15 Watt DC-DC Converters

IMX15, IMY15, IMS15 Series Data Sheet 15 Watt DC-DC Converters Description 0.6.6" 0. 0.".0" The IMX, IMS, and IMY Series of board mountable Watt DC-DC converters have been designed according to the latest industry requirements and standards. The converters are particularly

More information

HR/ER Series Data Sheet 144/288 Watt DC-DC Converters, 10:1 Input Range

HR/ER Series Data Sheet 144/288 Watt DC-DC Converters, 10:1 Input Range 44/88 Watt DC-DC Converters, : Input Range 6.4" TE 8." 6 TE 68 6.6" 68 6.6" 4.4" U 4.4" U Features Extremely wide input voltage range from to 68 VDC in the same converter (HR Series) RoHS-compliant for

More information

IMX7, IMS7 Series Data Sheet 7-Watt DC-DC Converters

IMX7, IMS7 Series Data Sheet 7-Watt DC-DC Converters Description 25.4.".5.42" 5.8 2." The IMX7/IMS7 Series of board-mountable 7 Watt DC-DC converters have been designed according to the latest industry requirements and standards. The converters are particularly

More information

HP Series Data Sheet Watt 10:1 DC-DC Converters

HP Series Data Sheet Watt 10:1 DC-DC Converters Features Extremely wide input voltage range from 2.5 to 54 VDC in the same model RoHS-compliant Class I equipment Compliant with EN 555, EN 52-3-2, and IEC/EN 6-4-2, -3, -4, -5, -6, -8. Fire&smoke: Compliant

More information

RCM150/300 Series 150/300 W DC-DC Converters

RCM150/300 Series 150/300 W DC-DC Converters RCM5/3 Series 5/3 W DC-DC Converters The RCM Series converters are reliable power supplies for railway and transportation systems. There are 2 input voltage ranges covering all common railway batteries.

More information

IMS6 Series Data Sheet, 6-Watt DC-DC Converters

IMS6 Series Data Sheet, 6-Watt DC-DC Converters Input to output electric strength test up to kvdc Input voltage ranges: 8 to 36 and 36 to 75 VDC Single and dual outputs of 5,, & 5 VDC Features RoHS leadsolderexempt compliant Wide input voltage ranges

More information

LRS Series AC-DC Subrack Systems MK007

LRS Series AC-DC Subrack Systems MK007 MK007 is a power supply system designed for railway and subway application. The applicable railway standards, mainly EN 5055, EN 502-4, and the respective AREMA standards are observed. The power supply

More information

W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters

W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters , 0 Watt AC-DC and DC-DC DIN-Rail Converters, 0 Watt AC-DC (DC-DC) Converters Convert Select Features RoHS lead-free-solder and lead-solder-exempted products are available Rugged mm DIN-rail snap-fit design

More information

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input. The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. The MPU150-4530G and MPU150-4350G provide high current +3.3 V and

More information

POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled Manual. 2. Features. 1. Introduction

POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled Manual. 2. Features. 1. Introduction Table of Contents 1. Introduction P1 2. Features P1 3. Block diagram P2 4. Options description P3 5. Input P3 6. Output P4 7. Auxiliary functions P5 8. Electromagnetic P6 9. Mechanical P8 10. Connector

More information

6 Watt DC-DC Converters IMR 6-Series

6 Watt DC-DC Converters IMR 6-Series Benign Environment DC-DC Converters

More information

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD. The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet

More information

25 Watt DC-DC Converters IMS 25 Series

25 Watt DC-DC Converters IMS 25 Series 5 Watt DC-DC Converters IMS 5 Series Wide input voltage ranges up to 75 V DC Single output up to 5 V DC 500 V DC I/O electric strength test voltage Industry standard pin-out Fixed frequency operation High

More information

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters 7, 00 Watt AC-DC and DC-DC DIN-Rail Converters 7, 00 Watt AC-DC (DC-DC) Converters Convert Select 9 7.6".9" 8." Features RoHS lead-free-solder and lead-solder-exempted products are available Rugged mm

More information

CCH400 & CCH600 Series

CCH400 & CCH600 Series CCH4 & CCH6 Series 4 W & 6 W - Baseplate Cooled Compact 8.4 (214 mm) x 4 (12 mm) x 1.69 (43 mm) Package High Efficiency up to 9% -4 C to +85 C Baseplate Operating Temperature No Fan, Quiet Operation MIL-STD-461

More information

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available. ECC100 Series -40 ºC to +75 ºC Operation 100 W - Baseplate Cooled High Efficiency Resonant Topology Screw Terminals Available 5V Standby Output Remote On/Off & Power OK Signal 3 Year Warranty The ECC100

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION The Bel Power Solutions MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety,

More information

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C. RoHS Lead-Solder-Exemption Compliant Automatic 115/230 Input Voltage Selection All Outputs Fully Regulated Remote Sense, Overvoltage Protection and Overtemperature Protection Power Fail Signal Included

More information

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark. The MPB150 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC) to meet the requirements of networking and data communications systems, as

More information

W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters

W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters 5, 50 Watt AC-DC and DC-DC DIN-Rail Converters Features RoHS lead-free-solder and lead-solder-exempted products are available Rugged 5 mm DIN-rail snap-fit design Class I equipment Universal AC-input with

More information

Datasheet. IC50X, 250 W Single-Output 600 Vin 750 Vin. Rev00

Datasheet. IC50X, 250 W Single-Output 600 Vin 750 Vin. Rev00 intrexis AG Tobelraastrasse 4 CH-8212 Neuhausen am Rheinfall SWITZERLAND Tel +41 (0)525111190 www.intrexis.ch Fax +41 (0)525111199 info@intrexis.ch Datasheet IC50X, 250 W Single-Output 600 Vin 750 Vin

More information

CPA /CPD Series Data Sheet Watt CompactPCI AC-DC and DC-DC Converters

CPA /CPD Series Data Sheet Watt CompactPCI AC-DC and DC-DC Converters 00 3.94" 3 U Description 40.4.6" 8 HP 62.5 6.4" 233.3 7.8" 6 U The CPA and CPD Series are highly reliable power supplies for CompactPCI systems, which are increasingly used in communications, industrial,

More information

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Bel Power Solutions MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance

More information

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Ripple & Max. capacitive Output Current

Ripple & Max. capacitive Output Current 0 Watts xxx Series Wide 4: Input Range Single Output Industry Standard /4 Brick -40 C to +0 C Operation 0 VDC Isolation Output Trim ±0% Remote On/Off Year Warranty Dimensions: QSC0:. x.4 x 0. (.9 x. x.

More information

POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled. Preliminary

POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled. Preliminary Preliminary Description The DBA series, very compact and low profi le AC/DC power supply up to in chassis format, incorporates input filtering, input and output protections, very robust mechanical mounting

More information

200 WATT TH SERIES DC/DC CONVERTERS

200 WATT TH SERIES DC/DC CONVERTERS Features 4:1 Input voltage range High power density Small size 2.4 x 2.28 x 0.65 Efficiency up to 90 Excellent thermal performance with metal case Pulse-by-pulse current limiting Over-temperature protection

More information

Series AM50E-NZ 50 Watt DC-DC Converter

Series AM50E-NZ 50 Watt DC-DC Converter FEATURES: Wide Input range 2:1 Input to Output Isolation of 1500 High Efficiency up to 93% Input Over Voltage and Under Voltage Lockout Remote On/Off Control Output OVP, OCP & SCP Trim Adjustment Operating

More information

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3 HPU1K5 Series Low Profile 1.7 (43.2 mm), Industrial Supply Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals Output Power up to 1500 W Load dependant variable speed fans for audible

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

Industrial Applications Telecom Daracom

Industrial Applications Telecom Daracom ABC200 Series is a family of compact and efficient AC-DC power supplies suited for telecom datacom and many other industrial applications. This family meets the international information technology safety

More information

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output THN 20WI Series Application Note DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output Pending Applications Wireless

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 Low Output Ripple 4 500 Vdc Output Isolation

More information

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant SHP350 Series 420 W High Line Output Power Rugged Industrial Construction Variable Speed Fan for Noise Reduction -40 C to +70 C Operation AC OK, Remote On/Off and Active Current Share Screw Terminals SEMI

More information

C B. Models. Models 2MOPP

C B. Models. Models 2MOPP AC/DC Medical Power Supplies High power density 3" x 5" open frame medical power supply 450 Watt with forced air cooling 320 Watt convection cooled without derating up to 50 C Medical certification to

More information

CPA, CPD Series Data Sheet Watt CompactPCI AC-DC and DC-DC Converters

CPA, CPD Series Data Sheet Watt CompactPCI AC-DC and DC-DC Converters 00 3.94" 3 U Description 40.4.6" 8 HP 62.5 6.4" 233.3 7.8" 6 U The CPA and CPD Series are highly reliable power supplies for CompactPCI systems, which are increasingly used in communications, industrial,

More information

Industrial Serie +600S

Industrial Serie +600S D A T A S H E E T Industrial Serie +6S Modular Configurable Reduced fan noise Enhanced Line Derating 6 watts in the palm of your hand The +6S series fetures improved low input line derating delivers 6

More information

SPECIFICATION. Online UPS 3000VA

SPECIFICATION. Online UPS 3000VA Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Mount Converters

W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Mount Converters PRODUCT SERVICE Production monitored Type tested W Series Data Sheet Features Rugged 5 mm DIN-rail snap-fit design Class I equipment Single or double-outputs for 24, 6, or 48 V 0 4.05" 4 4.49" 8 5.4" RoHS

More information

Datasheet intrexis Boardnet Converter Platform IC304, 500 W-Output Single-Output 24 Vin 110 Vin

Datasheet intrexis Boardnet Converter Platform IC304, 500 W-Output Single-Output 24 Vin 110 Vin intrexis AG Tobelraastrasse 4 CH-8212 Neuhausen am Rheinfall SWITZERLAND Tel +41 (0)525111190 www.intrexis.ch Fax +41 (0)525111199 info@intrexis.ch Datasheet intrexis Boardnet Converter Platform IC304,

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 500 Vdc Output Isolation 4 Continuous Short

More information

CPA, CPD Series Data Sheet Watt CompactPCI AC-DC and DC-DC Converters

CPA, CPD Series Data Sheet Watt CompactPCI AC-DC and DC-DC Converters 00 3.94" 3 U 233.3 7.8" 6 U 40.6.6" 8 HP 62.5 6.4" Description 40.4.6" 8 HP 62.5 6.4" The CPA and CPD Series are highly reliable power supplies for CompactPCI systems, which are increasingly used in communications,

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Compact PCI CPA / CPD Series

Compact PCI CPA / CPD Series Compact PCI CPA / CPD Series Features Compliant to PICMG CompactPCI specifications Wide range DC or AC input with PFC Extremely high efficiency and high power density Low inrush current 4 high current

More information

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2   FEATURES APPLICATIONS INCLUDE XS XS solo Ultra-high efficiency 1U size FEATURES The family of single output power supplies provides up to an incredible 1008W in an extremely compact package. Single output: 24V, 36V or 48V IEC60950

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

ABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications.

ABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications. is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications. The family meets the international information technology safety standards

More information

Low Profile. 3 Year Warranty

Low Profile. 3 Year Warranty MCC Series 400 W Regulated Output Optional 200 W Non-regulated Conditioned Rail 1 to 4 Configurable Outputs MIL-STD-1275 and DEF-STAN 61-5 MIL-STD-461 and DEF-STAN 59-411 Low Profile Rugged Construction

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Single negative output

Single negative output SIL25C SERIES Single negative output Trim range (-4.5 Vdc to -5.5 Vdc) High power density design means reduced board space requirement Remote sense Power good output signal (open collector) Operating ambient

More information

QUARTER-BRICK SERIES Single Output Performance Products

QUARTER-BRICK SERIES Single Output Performance Products Quarter-Brick Series 100 A DC-DC QUARTER-BRICK SERIES Single Output Performance Products High efficiency topology High output current Low profile, 0.300 inch (7.62 mm) height Unprecedented useable output

More information

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3 , Features High power density 40 W power supply (enclosed / open frame) 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3

More information

Voltage Adjustment. Load Regulation

Voltage Adjustment. Load Regulation HIGH DENSITY, CONFIGURABLE AC-DC POWER SUPPLY RCB1200 SERIES DS RCB1200 RE02 NOEMBER 2010 Description The RCB1200 is a modular, user configurable power supply offering unrivalled performances and flexibility.

More information

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26 Total Power: 65-75 W Input Voltage: 85-264 VAC 120-370 VDC* # of Outputs: Single, dual, triple SPECIAL FEATURES Universal Input 3 x 5 footprint Low profile fits 1U applications EN61000-3-2 compliance option

More information

CompactPCI CPA, CPD Series Data Sheet Watt AC-DC and DC-DC Converters

CompactPCI CPA, CPD Series Data Sheet Watt AC-DC and DC-DC Converters 00 3.94" 3 U 233.3 7.8" 6 U 40.6.6" 8 HP 62.5 6.4" Description 40.4.6" 8 HP 62.5 6.4" The CPA and CPD Series are highly reliable power supplies for CompactPCI systems, which are increasingly used in communications,

More information

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max. TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins

More information

CompactPCI CPA, CPD Series Data Sheet Watt AC-DC and DC-DC Converters

CompactPCI CPA, CPD Series Data Sheet Watt AC-DC and DC-DC Converters 233.3 7.8" 6 U 3.94" 3 U 4.4.6" 8 HP 62.5 6.4" Features 4.6.6" 8 HP 62.5 6.4" Description The CPA and CPD Series are highly reliable power supplies for CompactPCI systems, which are increasingly used in

More information

LB115S 115W Single Output

LB115S 115W Single Output Features Small size of 2 x 4 x 1.3 75W convection cooled/115 Watts with 200 LFM Universal Input 90-264Vac Meets EN55015 Conducted EMI Meets IEC61000-3-2 Class C for less than 1 Watt to full power Approved

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TIB Series, 80 480 W Slim profile, reduced module width High Power Factor up to 99% High efficiency up to 94% True back power immunity Low heat dissipation 150% peak current Automatic

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope Electrical Specification for: Compact PCI - 6U - AC - 700W Telkoor Part Number: 900-7802-0000 SCALE RELEASE DATE 11/11/13 SHEET 1 OF 7 VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective

More information

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15 Total Power: 40-50 W Input Voltage: 90-264 VAC 120-370 VDC # of Outputs: Single, dual, triple SPECIAL FEATURES 4.25 x 2.5 x 1.15 inch package (1U applications) Universal input Overvoltage and short circuit

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

QME48T40 DC-DC Series Data Sheet VDC Input; A Output

QME48T40 DC-DC Series Data Sheet VDC Input; A Output Applications Telecommunications Data communications Wireless communications Servers, Workstations Benefits High efficiency no heat sink required Higher current capability at 70 ºC than most competitors

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

TB65 65W Single Output Test and Measurement/Industrial Series

TB65 65W Single Output Test and Measurement/Industrial Series Features 2.0 x 3.5 x 1.3 Package TB65 Up to 65W Convection Cooled Output Power Compliant to high levels of EMC per EN61000-4 15kV ESD (Air), 8kV (Contact) 4kV Surge Meets Class B Conducted EMI with 6db

More information

DC-DC CONVERTER HFBC60-xxW/O

DC-DC CONVERTER HFBC60-xxW/O DC-DC CONVERTER HFBC60-xxW/O RAILWAY CONVERTER. FOR CHASSIS MOUNTING HIGHLIGHTS + Output Power up to 60 Watts + Ultra Wide Input Range + Wide Temperature Range + Hold-up-time > 10ms + RoHS compliance +

More information

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25

More information

Metal Case Power Supplies

Metal Case Power Supplies , 120 480 Watt Features Compact U-bracket and enclosed power supplies Screw terminal block Very high efficiency up to 93 % No internal fan for 120 W & 240 W models. Universal input 90 264 VAC Adjustable

More information

QUARTER-BRICK SERIES Single Output Value Products

QUARTER-BRICK SERIES Single Output Value Products Quarter-Brick Series 50 A DC-DC QUARTER-BRICK SERIES Single Output Value Products High efficiency topology High output current Low profile, 0.300 inch (7.62 mm) height Unprecedented useable output power

More information

CB Scheme UL508 UL ATEX II3G

CB Scheme UL508 UL ATEX II3G Industrial Power Supplies UL Hazloc Class I, division 2 approval and ATEX certification SEMI F47 compliant for voltage sag immunity Rugged metal case with optional side-mounting Very high efficiency up

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller. The TCP3500 series is an AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (No Fans) makes this power supply series suitable for a wide variety of Industrial

More information

Primary switch mode power supplies Product group picture

Primary switch mode power supplies Product group picture Primary switch mode power supplies Product group picture /1 ABB Catalog Electronic Products and Relays 2015 2CDC 110 004 C0210 Primary switch mode power supplies Table of contents Primary switch mode power

More information

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES Advanced Energy's Xsolo series, part of our low voltage solutions, delivers an incredible convection-cooled 504 W in an

More information

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good XS XS Xsolo 400W-800W solo Ultra-high efficiency 1U size FEATURES Single output: 24V or 48V EN60950 2 nd Edition & EN60601-1 2 nd and 3 rd Edition Ultra high efficiency, >92% Low profile: 1U height (40mm)

More information

SXN15 48V SERIES. Dual output TÜV. High Efficiency DC/DC Converters

SXN15 48V SERIES. Dual output TÜV. High Efficiency DC/DC Converters SXN15 48V SERIES Dual output High efficiency topology, 86% typical at 5V/3.3V Wide operating temperature, up to and exceedingly 65ºC (natural convection) 9% to 11% output trim No minimum load Overvoltage

More information

2-Product Selection. Multiple output model : CGDI - input output output output. Input Voltage Range. Transient

2-Product Selection. Multiple output model : CGDI - input output output output. Input Voltage Range. Transient DC/DC CONVERTER CGDI Wide Input TETHYS : 30W POWER 3:1 & 4:1 Wide Input Configurable Multiple Outputs Metallic case - 1 00 Isolation Highly configurable DC/DC converter Up to 6 outputs and 3 independants

More information