MX283027A-002 Bluetooth Test Software Operation Manual Remote Control
|
|
- Winfred Williamson
- 6 years ago
- Views:
Transcription
1 MX283027A-002 Bluetooth Test Software Operation Manual Remote Control Second Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety and warning information is provided within the MS2830 Signal Analyzer Operation Manual Mainframe Operation and MX283027A-002 Bluetooth Test Software Operation Manual Operation. Please also refer to this document before using the equipment. Keep this manual with the equipment. ANRITSU CORPORATION Document No.: M-W3517AE-2.0
2 Safety Symbols To prevent the risk of personal injury or loss related to equipment malfunction, Anritsu Corporation uses the following safety symbols to indicate safety-related information. Ensure that you clearly understand the meanings of the symbols BEFORE using the equipment. Some or all of the following symbols may be used on all Anritsu equipment. In addition, there may be other labels attached to products that are not shown in the diagrams in this manual. Symbols used in manual DANGER This indicates a very dangerous procedure that could result in serious injury or death if not performed properly. WARNING CAUTION This indicates a hazardous procedure that could result in serious injury or death if not performed properly. This indicates a hazardous procedure or danger that could result in light-to-severe injury, or loss related to equipment malfunction, if proper precautions are not taken. Safety Symbols Used on Equipment and in Manual The following safety symbols are used inside or on the equipment near operation locations to provide information about safety items and operation precautions. Ensure that you clearly understand the meanings of the symbols and take the necessary precautions BEFORE using the equipment. This indicates a prohibited operation. The prohibited operation is indicated symbolically in or near the barred circle. This indicates an obligatory safety precaution. The obligatory operation is indicated symbolically in or near the circle. This indicates a warning or caution. The contents are indicated symbolically in or near the triangle. This indicates a note. The contents are described in the box. These indicate that the marked part should be recycled. MX283027A-002 Bluetooth Test Software Operation Manual Remote Control 24 June 2011 (First Edition) 30 September 2011 (Second Edition) Copyright 2011, ANRITSU CORPORATION. All rights reserved. No part of this manual may be reproduced without the prior written permission of the publisher. The contents of this manual may be changed without prior notice. Printed in Japan ii
3 Notes On Export Management This product and its manuals may require an Export License/Approval by the Government of the product's country of origin for re-export from your country. Before re-exporting the product or manuals, please contact us to confirm whether they are export-controlled items or not. When you dispose of export-controlled items, the products/manuals need to be broken/shredded so as not to be unlawfully used for military purpose. iii
4 iv
5 About This Manual Associated Documents The operation manuals for the MX283027A-002 Bluetooth Test Software are comprised as shown in the figure below. MS2830 Signal Analyzer Operation Manual Mainframe Operation MS2690A/MS2691A/MS2692A and MS2830A Signal Analyzer Operation Manual Mainframe Remote Control MX283027A Wireless Network Device Test Software Operation Manual (Operation) MX283027A-002 Bluetooth Test Software Operation Manual (Operation) MX283027A-002 Bluetooth Test Software Operation Manual (Remote Control) Signal Analyzer Operation Manual (Mainframe Operation) Signal Analyzer Operation Manual (Mainframe Remote Control) Description of basic operations, maintenance procedures, common functions and common remote functions of the mainframe Wireless Network Device Test Software Operation Manual (Operation) This describes basic operations and functions of the Wireless Network Device Test Software. Bluetooth Test Software Operation Manual (Operation) This describes basic operations and functions of the Bluetooth Test Software. Bluetooth Test Software Operation Manual (Remote Control) <This document> This document describes the remote operation of Bluetooth Test Software. I
6 Table of Contents For Safety... About This Manual... iii I Chapter 1 Outline Outline Basic Flow of Control How to use Native Mode Setting Numeric Program Data Chapter 2 SCPI Device Message Details Selecting Application Device Messages for Setting Basic s Device Messages for Setting System s Device Messages for Utility Common Measurement Measurement Chapter 3 SCPI Status Register ing Measurement Status STATus:QUEStionable Register STATus:OPERation Register II
7 1 2 3 III
8 IV.
9 Chapter 1 Outline This chapter outlines the remote control operation of the MX283027A-002 Bluetooth Test Software (hereinafter referred to as this application ) Outline Interface Controlled application Basic Flow of Control Initialization Setting of basic parameters Setting of batch measurement-common parameters Batch measurement How to use Native Mode Setting Numeric Program Data Outline 1-1
10 Chapter 1 Outline 1.1 Outline The MX283027A-002 can be controlled from an external controller (PC) by remote control commands using the MS2830A Signal Analyzer (hereafter referred to as this instrument ). The remote control commands are defined by the SCPI format Interface This instrument has GPIB, Ethernet, and USB interfaces for remote control. Only one of these can be used at once Controlled application The interface is automatically determined when a command is received at the start of communication. This instrument enters the remote state after the interface has been determined. At remote-interface operation, the front panel lamp lights; the lamp is off at local-interface operation. Refer to the MS2690A/MS2691A/MS2692A and MS2830A Signal Analyzer manual (Mainframe, Remote Control) for more details of the basic operations for remote control, such as interface setting. Two types of the remote control commands can be used with this instrument: commands that are commonly applied to this instrument itself or all the applications (hereinafter, referred to as, Common commands ), and the other commands unique to the applications. Common commands can be executed at any time, regardless of the currently controlled application. However, commands unique to an application can be executed at the controlled application. If it is executed at another application, the command is not executed or an error occurs. In this instrument, multiple applications can be loaded at the same time. Only one application resource can be executed per piece of hardware at one time. The MX283027A-002 measures an input signal by using the resource of RF Input. Thus, the MX283027A-002 cannot be executed at the same time with another application using the same resource such as the signal analyzer function. In order to execute a function unique to the application by using the remote control, you need to select this application while it has been running. Furthermore, the MX283027A-002 can be executed at the same time as another application that uses by itself a resource not used by this application, such as the Vector Signal Generator. 1-2
11 1.2 Basic Flow of Control 1.2 Basic Flow of Control This section describes the basic remote control command programming operations for measuring Bluetooth signals. 1 Figure shows the flow of the basic control process. The order in which the measurement functions are executed can be rearranged, but the parameter settings and measurement function type that are applied to the measurement, and the measurement execution order cannot be changed. Outline Start Initialization Alteration of Conditions Modulation Characteristics Measurement Transmission Power Measurement ICFT Measurement Carrier Frequency Drift Measurement EDR Carrier Freq Stability and Mod Accuracy Measurement EDR Relative Transmit Power Measurement EDR Differential Phase Encoding Measurement Average Processing End Figure Basic Flow of Control (1) Initialization Initialize the communication interface and the parameters, and set the communication mode Initialization 1-3
12 Chapter 1 Outline (2) Setting Basic s Set the parameters applied in common to all measurements, such as carrier frequency and input level Setting of basic parameters (3) Setting Common Batch Measurement s Set the common parameters for the Batch measurement functions that are executed by using this application. This includes such as the trigger, modulation mode, and bandwidth Setting of batch measurement-common parameters (4) Batch measurement Execute in order the measurement functions executed with the MX283027A-002. First, select the measurement functions to be executed. Next, set the storage mode for each measurement function. Finally perform the measurement and read out the measurement results Batch measurement 1-4
13 1.2 Basic Flow of Control Initialization As part of the initial settings, perform the preparations for using the measuring instrument and the application. The following actions are included in the initial settings: (1) Initializing Communication Interface The remote control interface to be used is initialized so sending and receiving of commands can start. For details, refer to MS2690A/MS2691A/MS2692A and MS2830A Signal Analyzer manual (Mainframe Remote Control). (2) Setting Language Mode and Format The language mode and the response format used to communicate are set. For details, refer to MS2690A/MS2691A/MS2692A and MS2830A Signal Analyzer manual (Mainframe Remote Control). (3) Starting the application The application is loaded. The Signal Analyzer and Spectrum Analyzer applications should be loaded, too. (4) Selecting Application Select this application. (5) Initialization All parameters and statuses are reset at initialization. (6) Setting Measurement Mode After initialization, the measurement mode is at continuous measurement mode. To select single measurement mode, switch to the single measurement mode. 1 Outline 1-5
14 Chapter 1 Outline Start Initialization of Communication Interface Setting Language Mode and Mode INST CONFIG SYST:LANG SCPI SYST:RES:MODE A Starting Application SYST:APPL:LOAD WDEVICE SYST:APPL:LOAD SIGANA SYST:APPL:LOAD SPECT INST WDEVICE Selecting Application *RST *CLS Initialization INIT:CONT OFF Setting Measurement Mode End Figure Initialization Flow and Example 1-6
15 1.2 Basic Flow of Control Setting of basic parameters Set the common parameters (carrier frequency, input level, etc.) using the MX283027A-002/Signal Analyzer/Spectrum Analyzer. The basic parameters include the following: (1) Carrier Frequency (2) Input Level (Reference Level Attenuator) 1 Outline (3) Level Offset Start FREQ:CENT 2.402GHZ Setting Carrier Frequency Setting Input Level POW:RANG:ILEV DBM Setting Level Offset DISP:WIND:TRAC:Y:RLEV:OFFS:STAT ON DISP:WIND:TRAC:Y:RLEV:OFFS 0.25DB End Figure Flow of Basic Setting and Example 1-7
16 Chapter 1 Outline Setting of batch measurement-common parameters Set the parameters used in common for the batch measurement functions executed in this application. The parameters can be set in any order, unless otherwise specified. (1) Trigger (a) Trigger Switch (b) Trigger Source (c) Trigger Slope (d) Trigger Delay (2) Bluetooth Standard (3) Power Class (4) Packet Type (5) Burst Interval (6) Burst Threshold 1-8
17 1.2 Basic Flow of Control Start Setting Trigger 1 TRIG ON TRIG:SOUR WIF TRIG:SLOP POS TRIG:DEL 0 Outline RAD:STAN STAN BR Setting Bluetooth Standard BT:PCL PC1 Setting Power Class BT:PTYP DH1 Setting Packet Type BT:CAPT:BURS:INT 2MS Setting Burst Interval BT:CAPT:BURS:THR 30 Setting Burst Threshold End Figure Flow of Common Settings for Batch Measurement and Example 1-9
18 Chapter 1 Outline Batch measurement The Batch measurement is executed in the following order: (1) Selecting the measurement function. (2) Setting measurement parameters The followings are the parameters applied to the Modulation Characteristics measurement. (a) Modulation Characteristics Measurement (b) Storage Mode (c) Storage Count (d) Hold Result (e) Delta f1 Average Upper Limit (f) Delta f1 Average Lower Limit (d) Delta f2 Max Lower Limit (e) Delta f2 Average/Delta f1 Average Lower Limit (3) Executing measurement and querying the result 1-10
19 1.2 Basic Flow of Control CONF:BT Start Selecting Measurement Setting Measurement s 1 Outline BT:MCH ON BT:MCH:AVER ON BT:MCH:AVER:COUN 10 BT:MCH:HRES DF1 BT:MCH:LIM:DF1:DATA 175KHZ BT:MCH:LIM:DF1:LOW:DATA 145KHZ BT:MCH:LIM:DF2:LOW:PEAK 115KHZ BT:MCH:LIM:DFR:LOW:DATA 0.8 Measurement and Reading Out Measured Results READ:BT? STAT:ERR? End Figure Modulation Characteristics Measurement Flow and Example 1-11
20 Chapter 1 Outline 1.3 How to use Native Mode This instrument defines the syntax/format types of the remote control commands as Language mode. The language mode has two modes: SCPI and Native. (1) SCPI mode The SCPI mode processes commands conforming to the syntax/format defined in SCPI (ver1999.0). For programming, you can use the character string in long/short form format and can omit angled bracket ( [ ] ) definition character strings. On the Configuration screen, the SCPI mode is automatically set after transmitting SYST:LANG SCPI. (2) Native mode The Native mode processes commands that are in this instrument s own definition type. Unless otherwise specified, the character string of a command header is fixed. If application commands are defined only by the SCPI mode, character strings converted according to the conversion rules are the commands in the Native mode. For programming, you cannot use the grammar of SCPI mode, such as character string in long/short form format and cannot omit any angled bracket ( [ ] ) definition character strings. On the Configuration screen, the Native mode is automatically set after transmitting SYST:LANG NAT. 1-12
21 1.3 How to use Native Mode SCPI Mode SYST:LANG SCPI Native Mode (D efault) 1 definition definition (Native-unique format) AAAAaa:BBBBbb[:CCCCcc]:D E <n> Programming AAAAaa:BBBBbb:CCCCcc:D 0 VWXYZ1 <n> Programming VWXYZ 0 Outline AAAA:BBBB:CCCC:D 0 AAAA:BBBB:D 0 AAAA:BBBB:CCCC:E 0 AAAA:BBBB:E 0 definition (converted from SCPI format) AAAA:BBBB:CCCC:D <n> Programming AAAA:BBBB:CCCC:D 0 SYST:LANG NAT AAAA:BBBB:D 0 (error) Figure SCPI and Native Modes The MX283027A-002 is only defined by the SCPI mode commands. You need to follow the conversion rules below in order to control the MX283027A-002 by using the Native mode. Conversion Rules 1. Move the numeric parameters in the SCPI mode program header to the head of the arguments. Omit parameters that represent only one type of value and can be omitted. Leave parameters that represent only one type of value but cannot be omitted. 2. Use the first node if multiple ones can be selected. 3. Delete layers that can be deleted. 4. Alter all the long forms into the short ones. 5. Omit the colon ( : ) at the head of the command. 1-13
22 Chapter 1 Outline Example 1 :Convert CALCulate:MARKer[1] 2[:SET]:CENTerinto a Native mode. [1] Put a numeric parameter of the program header at the head of the argument. :CALCulate:MARKer[1] 2[:SET]:CENTer :CALCulate:MARKer[:SET]:CENTer <integer> (the argument <integer> represents the numeric value 1 or 2) [2] Delete layers that can be deleted. :CALCulate:MARKer[:SET]:CENTer <integer> :CALCulate:MARKer:CENTer <integer> [3] Alter all the long forms into the short ones. :CALCulate:MARKer:CENTer <integer> :CALC:MARK:CENT <integer> [4] Omit the colon ( : ) at the head of the command. :CALC:MARK:CENT <integer> CALC:MARK:CENT <integer> Example 2 [:Convert SENSe]:BPOWer :TXPower[:STATe]? into a Native mode. 1. Use the first node if multiple ones can be selected. [:SENSe]:BPOWer :TXPower[:STATe]? [:SENSe]:BPOWer[:STATe]? 2. Delete layers that can be deleted. [:SENSe]:BPOWer[:STATe]? :BPOWer? 1-14
23 1.3 How to use Native Mode 3. Alter all long forms into the short ones. :BPOWer? :BPOW? 1 Omit the colon ( : ) at the head of the command. :BPOW? BPOW? Outline 1-15
24 Chapter 1 Outline 1.4 Setting Numeric Program Data The following character programs can be used for setting numeric program data (numeric parameters). (1) DEFault After DEFault has been set to numeric program data, the target parameter is set to the default value. (2) MINimum After MINimum has been set to numeric program data, the target parameter is set to the minimum value. (3) MAXimum After MAXimum has been set to numeric program data, the target parameter is set to the maximum value. In the MX283027A-002, DEFault, MINimum, and MAXimum can be used for the following parameters. <freq> <real> <rel_power> <integer> <time> 1-16.
25 Chapter 2 SCPI Device Message Details This chapter describes the detailed specifications of SCPI remote control commands for executing the functions of this application. The device messages are listed according to function. Refer to the MS2690A/MS2691A/MS2692A and MS2830A Signal Analyzer Operation Manual (Mainframe Remote Control) for detailed specifications of the IEEE488.2 common device messages and application common device messages. 2.1 Selecting Application Launching application :SYSTem:APPLication:LOAD WDEVICE :SYSTem:APPLication:UNLoad WDEVICE Selecting application :INSTrument[:SELect] WDEVICE CONFIG :INSTrument[:SELect]? :INSTrument:SYSTem WDEVICE,[ACTive] INACtive MINimum :INSTrument:SYSTem? WDEVICE Initialization :INSTrument:DEFault :SYSTem:PRESet Device Messages for Setting Basic s Carrier Frequency [:SENSe]:FREQuency:CENTer <freq> [:SENSe]:FREQuency:CENTer? [:SENSe]:BT:CHANnel <integer> [:SENSe]:BT:CHANnel? Input Level [:SENSe]:POWer[:RF]:RANGe:ILEVel <real> [:SENSe]:POWer[:RF]:RANGe:ILEVel? Level Offset :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet <rel_power> :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet? Level Offset State :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe OFF ON :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe? Device Messages for Setting System s Standard [:SENSe]:BT:RADio:STANdard BR EDR BLE [:SENSe]:BT:RADio:STANdard? Power Class [:SENSe]:BT:PCLass PC1 PC2 PC [:SENSe]:BT:PCLass? Packet Type [:SENSe]:BT:PTYPe DH1 DH3 DH5 2DH1 2DH3 2DH5 3DH1 3DH3 3DH5 AUTO [:SENSe]:BT:PTYPe? Burst Interval [:SENSe]:BT:CAPTure:BURSt:INTerval <real> [:SENSe]:BT:CAPTure:BURSt:INTerval? Access Address [:SENSe]:BT:BLE:AADDress <integer> [:SENSe]:BT:BLE:AADDress? SCPI Device Message Details 2
26 Chapter 2 SCPI Device Message Details Burst Threshold [:SENSe]:BT:CAPTure:BURSt:THReshold <integer> [:SENSe]:BT:CAPTure:BURSt:THReshold? Device Messages for Utility Erase Warm Up Message :DISPlay:ANNotation:WUP:ERASe Display Title :DISPlay:ANNotation:TITLe[:STATe] OFF ON :DISPlay:ANNotation:TITLe[:STATe]? Title Entry :DISPlay:ANNotation:TITLe:DATA <string> :DISPlay:ANNotation:TITLe:DATA? Common Measurement Measurement and control :INITiate:CONTinuous OFF ON :INITiate:CONTinuous? :INITiate:MODE:CONTinuous :INITiate:MODE:SINGle :INITiate[:IMMediate] :CONFigure? Trigger Switch :TRIGger[:SEQuence][:STATe] OFF ON :TRIGger[:SEQuence][:STATe]? Trigger source :TRIGger[:SEQuence]:SOURce EXTernal[1] IMMediate WIF RFBurst SG :TRIGger[:SEQuence]:SOURce? Trigger Slope :TRIGger[:SEQuence]:SLOPe POSitive NEGative :TRIGger[:SEQuence]:SLOPe? :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute <ampl> :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute? :TRIGger[:SEQuence]:DELay <time> :TRIGger[:SEQuence]:DELay? Measurement Measure :CONFigure:BT :INITiate:BT :FETCh:BT[n]? :READ:BT[n]? :MEASure:BT[n]? Modulation Characteristics [:SENSe]:BT:MCHar[:STATe] OFF ON [:SENSe]:BT:MCHar[:STATe]? [:SENSe]:BT:MCHar:AVERage[:STATe] OFF ON [:SENSe]:BT:MCHar:AVERage[:STATe]? [:SENSe]:BT:MCHar:AVERage:COUNt <integer> [:SENSe]:BT:MCHar:AVERage:COUNt? [:SENSe]:BT:MCHar:HRESult OFF DF1 DF [:SENSe]:BT:MCHar:HRESult? [:SENSe]:BT:MCHar:LIMit:DF1[:UPPer]:DATA <freq> [:SENSe]:BT:MCHar:LIMit:DF1[:UPPer]:DATA? [:SENSe]:BT:MCHar:LIMit:DF1:LOWer:DATA <freq> [:SENSe]:BT:MCHar:LIMit:DF1:LOWer:DATA?
27 Chapter 2 SCPI Device Message Details [:SENSe]:BT:MCHar:LIMit:DF2:LOWer:PEAK <freq> [:SENSe]:BT:MCHar:LIMit:DF2:LOWer:PEAK? [:SENSe]:BT:MCHar:LIMit:DFRatio:LOWer:DATA <real> [:SENSe]:BT:MCHar:LIMit:DFRatio:LOWer:DATA? Output Power [:SENSe]:BT:TXPower[:STATe] OFF ON [:SENSe]:BT:TXPower[:STATe]? [:SENSe]:BT:TXPower:AVERage[:STATe] OFF ON [:SENSe]:BT:TXPower:AVERage[:STATe]? [:SENSe]:BT:TXPower:AVERage:COUNt <integer> [:SENSe]:BT:TXPower:AVERage:COUNt? [:SENSe]:BT:TXPower:LIMit[:UPPer]:DATA <real> [:SENSe]:BT:TXPower:LIMit[:UPPer]:DATA? [:SENSe]:BT:TXPower:LIMit:LOWer:DATA <real> [:SENSe]:BT:TXPower:LIMit:LOWer:DATA? [:SENSe]:BT:TXPower:LIMit[:UPPer]:PEAK <real> [:SENSe]:BT:TXPower:LIMit[:UPPer]:PEAK? ICFT [:SENSe]:BT:ICFT[:STATe] OFF ON [:SENSe]:BT:ICFT[:STATe]? [:SENSe]:BT:ICFT:AVERage[:STATe] OFF ON [:SENSe]:BT:ICFT:AVERage[:STATe]? [:SENSe]:BT:ICFT:AVERage:COUNt <integer> [:SENSe]:BT:ICFT:AVERage:COUNt? [:SENSe]:BT:ICFT:LIMit[:UPPer]:DATA <freq> [:SENSe]:BT:ICFT:LIMit[:UPPer]:DATA? Carrier Frequency Drift [:SENSe]:BT:CFDRift[:STATe] OFF ON [:SENSe]:BT:CFDRift[:STATe]? [:SENSe]:BT:CFDRift:AVERage[:STATe] OFF ON [:SENSe]:BT:CFDRift:AVERage[:STATe]? [:SENSe]:BT:CFDRift:AVERage:COUNt <integer> [:SENSe]:BT:CFDRift:AVERage:COUNt? [:SENSe]:BT:CFDRift:LIMit[:UPPer]:DATA <freq> [:SENSe]:BT:CFDRift:LIMit[:UPPer]:DATA? [:SENSe]:BT:CFDRift:LIMit[:UPPer]:PEAK<freq> [:SENSe]:BT:CFDRift:LIMit[:UPPer]:PEAK? EDR Carrier Freq Stability and Mod Accuracy [:SENSe]:BT:EDR:DEVM[:STATe] OFF ON [:SENSe]:BT:EDR:DEVM[:STATe]? [:SENSe]:BT:EDR:DEVM:AVERage[:STATe] OFF ON [:SENSe]:BT:EDR:DEVM:AVERage[:STATe]? [:SENSe]:BT:EDR:DEVM:AVERage:COUNt <integer> [:SENSe]:BT:EDR:DEVM:AVERage:COUNt? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:FERRor:TOTal <freq> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:FERRor:TOTal? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:FERRor:BLOCk <freq> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:FERRor:BLOCk? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:FERRor:INITial <real> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:FERRor:INITial? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:DQPSk:DATA <real> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:DQPSk:DATA? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:8DPSk:DATA <real> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:8DPSk:DATA? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:DQPSk:PEAK <real> SCPI Device Message Details 2 2-3
28 Chapter 2 SCPI Device Message Details [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:DQPSk:PEAK? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:8DPSk:PEAK <real> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:8DPSk:PEAK? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:DQPSk:99Percent <real> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:DQPSk:99Percent? [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:8DPSk:99Percent <real> [:SENSe]:BT:EDR:DEVM:LIMit[:UPPer]:8DPSk:99Percent? EDR Relative Transmit Power [:SENSe]:BT:EDR:TXPower:RELative[:STATe] OFF ON [:SENSe]:BT:EDR:TXPower:RELative[:STATe]? [:SENSe]:BT:EDR:TXPower:RELative:AVERage[:STATe] OFF ON [:SENSe]:BT:EDR:TXPower:RELative:AVERage[:STATe]? [:SENSe]:BT:EDR:TXPower:RELative:AVERage:COUNt <integer> [:SENSe]:BT:EDR:TXPower:RELative:AVERage:COUNt? [:SENSe]:BT:EDR:TXPower:RELative:LIMit[:UPPer]:DATA <real> [:SENSe]:BT:EDR:TXPower:RELative:LIMit[:UPPer]:DATA? [:SENSe]:BT:EDR:TXPower:RELative:LIMit:LOWer:DATA <real> [:SENSe]:BT:EDR:TXPower:RELative:LIMit:LOWer:DATA? EDR Differential Phase Encoding [:SENSe]:BT:EDR:DPHase[:STATe] OFF ON [:SENSe]:BT:EDR:DPHase[:STATe]? [:SENSe]:BT:EDR:DPHase:AVERage[:STATe] OFF ON [:SENSe]:BT:EDR:DPHase:AVERage[:STATe]? [:SENSe]:BT:EDR:DPHase:AVERage:COUNt <integer> [:SENSe]:BT:EDR:DPHase:AVERage:COUNt? [:SENSe]:BT:EDR:DPHase:LIMit[:UPPer]:PER <real> [:SENSe]:BT:EDR:DPHase:LIMit[:UPPer]:PER?
29 2.1 Selecting Application 2.1 Selecting Application Table lists the device messages for setup operations such as loading/selecting/initializing an application. Load Application Table Device Messages for Selecting Application Device Message :SYSTem:APPLication:LOAD WDEVICE 2 Unload Application Application Switch Application Status Initialization :SYSTem:APPLication:UNLoad WDEVICE :INSTrument[:SELect] WDEVICE CONFIG :INSTrument[:SELect]? :INSTrument:SYSTem WDEVICE,[ACTive] INACtive MINimum :INSTrument:SYSTem? WDEVICE :INSTrument:DEFault :SYSTem:PRESet SCPI Device Message Details 2-5
30 Chapter 2 SCPI Device Message Details Launching application :SYSTem:APPLication:LOAD WDEVICE Load Application This command loads this application. :SYSTem:APPLication:LOAD WDEVICE Details This function loads an installed application and registers it to the Application Switch menu. To use this function set the target application to Config, by using :INSTrument[:SELect]. To load this application. SYST:APPL:LOAD WDEVICE :SYSTem:APPLication:UNLoad WDEVICE Unload Application This command exits this application. :SYSTem:APPLication:UNLoad WDEVICE Details This function exits an activated application and deletes it from the Application Switch menu. To use this function set the target application to Config, by using :INSTrument[:SELect]. To exit this application. SYST:APPL:UNL WDEVICE 2-6
31 2.1 Selecting Application Selecting application :INSTrument[:SELect] WDEVICE CONFIG Application Switch This command selects the controlled application. 2 :INSTrument[:SELect]? Application Switch :INSTrument[:SELect] <apl_name> <apl_name> WDEVICE CONFIG Application This application Config To switch the control target to this application. INST WDEVICE SCPI Device Message Details This command queries the controlled application. :INSTrument[:SELect]? <apl_name> Details <apl_name> WDEVICE SIGANA SPECT CONFIG Application This application Signal Analyzer Spectrum Analyzer Config WDEVICE is returned when a measurement function of this application is selected. To query the controlled application. INST? > WDEVICE 2-7
32 Chapter 2 SCPI Device Message Details :INSTrument:SYSTem WDEVICE,[ACTive] INACtive MINimum Application Switch and Window Status This command selects the control target application and specifies the window status. :INSTrument:SYSTem <apl_name>,<window> <apl_name> WDEVICE CONFIG Application This application Config <window> Window status ACTive Active INACtive Inactive MINimum Minimized When omitted Active To select this application with the window in active status. INST:SYST WDEVICE,ACT :INSTrument:SYSTem? WDEVICE Application Switch And Window Status This command queries the status of the specified application. :INSTrument:SYSTem? <apl_name> <status>,<window> 2-8
33 2.1 Selecting Application <apl_name> WDEVICE CONFIG <status> CURR RUN IDLE UNL <window> ACT INAC MIN NON Application This application Config Application status Executed and targeted for control Executed but not targeted for control Loaded but not executed Not loaded Window status Active Inactive Minimized Window not displayed To query the status of this application. INST:SYST? WDEVICE > CURR,ACT 2 SCPI Device Message Details 2-9
34 Chapter 2 SCPI Device Message Details Initialization :INSTrument:DEFault Preset Current Application This command initializes the settings and status of the currently selected application. :INSTrument:DEFault To initialize the settings and status of the currently selected application. INST:DEF :SYSTem:PRESet Preset Current Application This command initializes the settings and status of the currently selected application. Refer to :INSTrument:DEFault. To initialize the settings and status of the currently selected application. SYST:PRES 2-10
35 2.2 Device Messages for Setting Basic s 2.2 Device Messages for Setting Basic s Table lists the parameters applied in common to this application, such as frequency and level. Carrier Frequency Channel Number Input Level Level Offset Level Offset State Table Setting Basic s Device Message [:SENSe]:FREQuency:CENTer <freq> [:SENSe]:FREQuency:CENTer? [:SENSe]:BT:CHANnel <integer> [:SENSe]:BT:CHANnel? [:SENSe]:POWer[:RF]:RANGe:ILEVel <real> [:SENSe]:POWer[:RF]:RANGe:ILEVel? :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet <rel_power> :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet? :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe OFF ON 0 1 :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe? 2 SCPI Device Message Details 2-11
36 Chapter 2 SCPI Device Message Details Carrier Frequency [:SENSe]:FREQuency:CENTer <freq> Carrier Frequency This command sets the carrier frequency of the measured signal. [:SENSe]:FREQuency:CENTer <freq> <freq> Range Resolution Suffix code Default To set the carrier frequency to GHz. FREQ:CENT 1.000GHZ Carrier frequency 100 MHz to 3.6 GHz (With MS2830A-040) 100 MHz to 6 GHz (With MS2830A-041) 100 MHz to 13.5 GHz (With MS2830A-043) 1 Hz HZ, KHZ, KZ, MHZ, MZ, GHZ, GZ Hz is used when omitted GHZ 2-12
37 2.2 Device Messages for Setting Basic s [:SENSe]:FREQuency:CENTer? Carrier Frequency This command queries the carrier frequency of the measured signal. [:SENSe]:FREQuency:CENTer? 2 <freq> <freq> Range Resolution To query the carrier frequency. FREQ:CENT? > Carrier frequency 100 MHz to 3.6 GHz (With MS2830A-040) 100 MHz to 6 GHz (With MS2830A-041) 100 MHz to 13.5 GHz (With MS2830A-043) 1 Hz Value is returned in Hz units. SCPI Device Message Details 2-13
38 Chapter 2 SCPI Device Message Details [:SENSe]:BT:CHANnel <integer> Channel Number This command sets the carrier frequency according to channel number. [:SENSe]:BT:CHANnel <integer> <integer> Channel number Range 0 to 78 Default 0 To set the channel number to 1. BT:CHAN 1 [:SENSe]:BT:CHANnel? Channel Number This command queries the channel number setting. [:SENSe]:BT:CHANnel? <integer> <integer> Channel number Range 0 to 78 To query the channel number setting. BT:CHAN? >
39 2.2 Device Messages for Setting Basic s Input Level [:SENSe]:POWer[:RF]:RANGe:ILEVel <real> Input Level This command sets the input level of RF signals. 2 [:SENSe]:POWer[:RF]:RANGe:ILEVel <real> <real> Range Resolution Unit Suffix code Default To set the input level to 0 dbm. POW:RANG:ILEV 0 Input level ( Level Offset) to (30.00+Level Offset) dbm 0.01 db dbm DBM dbm is used when omitted dbm SCPI Device Message Details 2-15
40 Chapter 2 SCPI Device Message Details [:SENSe]:POWer[:RF]:RANGe:ILEVel? Input Level This command queries the input level of RF signals. [:SENSe]:POWer[:RF]:RANGe:ILEVel? <real> <real> Range Resolution To query the input level. POW:RANG:ILEV? > Input level ( Level Offset) to (30.00+Level Offset) dbm 0.01 db Value is returned in dbm units Level Offset :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet <rel_power> Level Offset Value This command sets the input level offset value. :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet <rel_power> <rel_power> Range Resolution Suffix code Default Offset value to db 0.01 db DB db is used when omitted db To set the input level offset value to +10 db. DISP:WIND:TRAC:Y:RLEV:OFFS
41 2.2 Device Messages for Setting Basic s :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet? Level Offset Value This command queries the input level offset value. :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet? 2 <rel_power> <rel_power> Range Resolution Offset value to db 0.01 db To query the input level offset value. DISP:WIND:TRAC:Y:RLEV:OFFS? > SCPI Device Message Details Level Offset State :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe OFF ON 0 1 Level Offset State This command enables/disables the offset function of the input level. :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe <switch> <switch> OFF 0 ON 1 To enable the input level offset function. DISP:WIND:TRAC:Y:RLEV:OFFS:STAT ON Enable/disable input level offset function Disabled (default) Enabled 2-17
42 Chapter 2 SCPI Device Message Details :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe? Level Offset State This command queries the state of the input level offset function. :DISPlay:WINDow[1]:TRACe:Y[:SCALe]:RLEVel:OFFSet:STATe? <switch> <switch> Enable/disable input level offset function 0 Disabled 1 Enabled To query the state of the input level offset function. DISP:WIND:TRAC:Y:RLEV:OFFS:STAT? >
43 2.3 Device Messages for Setting System s 2.3 Device Messages for Setting System s Table lists the device messages for the communication system of the measurement target. Table System Settings Device Message 2 Standard Power Class Packet Type Burst Interval Access Address Burst Threshold [:SENSe]:BT:RADio:STANdard BR EDR BLE [:SENSe]:BT:RADio:STANdard? [:SENSe]:BT:PCLass PC1 PC2 PC3 [:SENSe]:BT:PCLass? [:SENSe]:BT:PTYPe DH1 DH3 DH5 2DH1 2DH3 2DH5 3DH1 3DH3 3DH5 AUTO [:SENSe]:BT:PTYPe? [:SENSe]:BT:CAPTure:BURSt:INTerval <real> [:SENSe]:BT:CAPTure:BURSt:INTerval? [:SENSe]:BT:BLE:AADDress <integer> [:SENSe]:BT:BLE:AADDress? [:SENSe]:BT:CAPTure:BURSt:THReshold <integer> [:SENSe]:BT:CAPTure:BURSt:THReshold? SCPI Device Message Details 2-19
44 Chapter 2 SCPI Device Message Details Standard [:SENSe]:BT:RADio:STANdard BR EDR BLE Standard This command sets the standard of target signal when measuring Bluetooth signal. [:SENSe]:BT:RADio:STANdard <mode> <mode> BR EDR BLE Default Standard of target signal Analyzes as Basic Rate signal Analyzes as EDR signal Analyzes as Bluetooth Low Energy signal BR To set the standard of target signal to Basic Rate. BT:RAD:STAN BR [:SENSe]:BT:RADio:STANdard? Standard This command queries the standard of target signal when measuring Bluetooth signal. [:SENSe]:BT:RADio:STANdard? <mode> <mode> BR EDR BLE To query the standard of target signal BT:RAD:STAN? > BR Standard of target signal Analyzes as Basic Rate signal Analyzes as EDR signal Analyzes as Bluetooth Low Energy signal 2-20
45 2.3 Device Messages for Setting System s Power Class [:SENSe]:BT:PCLass PC1 PC2 PC3 Power Class This command sets the Power Class that automatically sets the limit value for Output Power measurement. 2 [:SENSe]:BT:PCLass <mode> <mode> Power Class PC1 Sets the limit value of Power Class 1. PC2 Sets the limit value of Power Class 2. PC3 Sets the limit value of Power Class 3. Default PC2 To set Power Class to Power Class 2. BT:PCL PC2 SCPI Device Message Details [:SENSe]:BT:PCLass? Power Class This command queries the Power Class. [:SENSe]:BT:PCLass? <mode> <mode> Power Class PC1 Sets the limit value of Power Class 1. PC2 Sets the limit value of Power Class 2. PC3 Sets the limit value of Power Class 3. To query the Power Class. BT:PCL? > PC2 2-21
46 Chapter 2 SCPI Device Message Details Packet Type [:SENSe]:BT:PTYPe DH1 DH3 DH5 2DH1 2DH3 2DH5 3DH1 3DH3 3DH5 AUTO Packet Type Details This command sets the packet type of input signal.when BLE is selected for the standard, it is analyzed as BLE signal irrespective of this setting. [:SENSe]:BT:PTYPe <mode> <mode> Packet Type DH1 Analyzes the input signal as DH1 (BR signal). DH3 Analyzes the input signal as DH3 (BR signal). DH5 Analyzes the input signal as DH5 (BR signal). 2DH1 Analyzes the input signal as 2-DH1 ( /4-DQPSK signal). 2DH3 Analyzes the input signal as 2-DH3 ( /4-DQPSK signal). 2DH5 Analyzes the input signal as 2-DH5 ( /4-DQPSK signal). 3DH1 Analyzes the input signal as 3-DH1 (8DPSK signal). 3DH3 Analyzes the input signal as 3-DH3 (8DPSK signal). 3DH5 Analyzes the input signal as 3-DH5 (8DPSK signal). AUTO Analyzes the input signal automatically. Default AUTo DH1,DH3,DH5 Available only when the selected standard is BR. When this is set when the selected standard is EDR, it is changed to BR. 2DH1,2DH3,2DH5,3DH1,3DH3,3DH5 Available only when the selected standard is EDR. When this is set when the selected standard is BR, it is changed to EDR. To set Packet Type to DH1. BT:PTYP DH1 2-22
47 2.3 Device Messages for Setting System s [:SENSe]:BT:PTYPe? Packet Type This command queries the packet type. [:SENSe]:BT:PTYPe? <mode> <mode> DH1 DH3 DH5 2DH1 2DH3 2DH5 3DH1 3DH3 3DH5 AUT To query the packet type. BT:PTYP? >DH1 Packet Type Analyzes the input signal as DH1 (BR signal). Analyzes the input signal as DH3 (BR signal). Analyzes the input signal as DH5 (BR signal). Analyzes the input signal as 2-DH1 ( /4-DQPSK signal). Analyzes the input signal as 2-DH3 ( /4-DQPSK signal). Analyzes the input signal as 2-DH5 ( /4-DQPSK signal). Analyzes the input signal as 3-DH1 (8DPSK signal). Analyzes the input signal as 3-DH3 (8DPSK signal). Analyzes the input signal as 3-DH5 (8DPSK signal). Analyzes the input signal automatically. 2 SCPI Device Message Details 2-23
48 Chapter 2 SCPI Device Message Details Burst Interval [:SENSe]:BT:CAPTure:BURSt:INTerval <real> Burst Interval This command sets the burst interval. [:SENSe]:BT:CAPTure:BURSt:INTerval <real> <real> Range Resolution Suffix code Default To set burst interval to 3000 s. BT:CAPT:BURS:INT 3000US Burst Interval Minimum value: 200 s Maximum value: the smaller value of the two: " or the longest T which is Storage Count T 2000 ms 1 s NS, US, MS, S s is used when omitted s 2-24
49 2.3 Device Messages for Setting System s [:SENSe]:BT:CAPTure:BURSt:INTerval? Burst Interval This command queries the burst interval. [:SENSe]:BT:CAPTure:BURSt:INTerval? <real> <real> Range Resolution Suffix code To query burst interval. BT:CAPT:BURS:INT? > Burst Interval Minimum value: 200 s Maximum value: the smaller value of the two: or the longest T which is Storage Count T 2000 ms 1 s None, value is returned in s units. 2 SCPI Device Message Details 2-25
50 Chapter 2 SCPI Device Message Details Access Address [:SENSe]:BT:BLE:AADDress <integer> Access Address This command sets Access Address used for BLE signal synchronization. [:SENSe]:BT:BLE:AADDress <integer> <integer> Access Address Range 0x to 0xFFFFFFFF Resolution 1 Suffix code None Default 0x To set the Access Address to 0x BT:BLE:AADD 0x [:SENSe]:BT:BLE:AADDress? Access Address This command queries Access Address used for BLE signal synchronization. [:SENSe]:BT:BLE:AADDress? <integer> <integer> Access Address Range 0x to 0xFFFFFFFF Resolution 1 Suffix code None To query the Access Address BT:BLE:AADD? >
51 2.3 Device Messages for Setting System s Burst Threshold [:SENSe]:BT:CAPTure:BURSt:THReshold <integer> Burst Threshold This command sets Burst Threshold level for burst detection. 2 [:SENSe]:BT:CAPTure:BURSt:THReshold <integer> <integer> Range Resolution Suffix code Default Burst Threshold 0 to 60 db 1 db None 30 db To set Burst Threshold level for burst detection to 30 db. BT:CAPT:BURS:THR 30 SCPI Device Message Details [:SENSe]:BT:CAPTure:BURSt:THReshold? Burst Threshold This command queries Burst Threshold level for burst detection. [:SENSe]:BT:CAPTure:BURSt:THReshold? <integer> <integer> Range Resolution Suffix code Burst Threshold 0 to 60 db 1 db None. Value is returned in db units. To query the Burst Threshold level for burst detection. BT:CAPT:BURS:THR? >
52 Chapter 2 SCPI Device Message Details 2.4 Device Messages for Utility Table lists the device messages for the utility function of the measurement target. Table Device Messages for Utility Erase Warm Up Message Display Title Title Entry Device Message :DISPlay:ANNotation:WUP:ERASe :DISPlay:ANNotation:TITLe[:STATe] ON OFF 1 0 :DISPlay:ANNotation:TITLe[:STATe]? :DISPlay:ANNotation:TITLe:DATA <string> :DISPlay:ANNotation:TITLe:DATA? 2-28
53 2.4 Device Messages for Utility Erase Warm Up Message :DISPlay:ANNotation:WUP:ERASe Erase Warm Up Message This command erases the warmup message displayed immediately after startup. 2 :DISPlay:ANNotation:WUP:ERASe To erase the warmup message DISP:ANN:WUP:ERAS Display Title :DISPlay:ANNotation:TITLe[:STATe] OFF ON 0 1 Display Title SCPI Device Message Details This command turns the title on/off. :DISPlay:ANNotation:TITLe[:STATe] <switch> <switch> OFF 0 ON 1 Title display On/Off Off On (Default) To display the title. DISP:ANN:TITL ON 2-29
54 Chapter 2 SCPI Device Message Details :DISPlay:ANNotation:TITLe[:STATe]? Display Title This command queries whether the title display is enabled/disabled. :DISPlay:ANNotation:TITLe[:STATe]? <switch> <switch> Title display On/Off 0 Off 1 On To query the title display On/Off state. DISP:ANN:TITL? > Title Entry :DISPlay:ANNotation:TITLe:DATA <string> Title Entry This command sets the title character string. :DISPlay:ANNotation:TITLe:DATA <string> <string> To set the title character string. DISP:ANN:TITL:DATA TEST' Character string within 32 characters enclosed by double quotes ( ) or single quotes ( ) 2-30
55 2.4 Device Messages for Utility :DISPlay:ANNotation:TITLe:DATA? Title Entry This command queries the title character string. :DISPlay:ANNotation:TITLe:DATA? 2 <string> <string> To query the title character string. DISP:ANN:TITL:DATA? > TEST Character string within 32 characters enclosed by double quotes ( ) or single quotes ( ) SCPI Device Message Details 2-31
56 Chapter 2 SCPI Device Message Details 2.5 Common Measurement Table lists the device messages for performing operations common to the measurement functions. Table Device Messages for Operations Common to Measurement s Continuous Measurement Single Measurement Initiate Configure Trigger Switch Trigger Source Trigger Slope Wide IF Trigger Level Trigger Delay Device Message :INITiate:CONTinuous OFF ON 0 1 :INITiate:CONTinuous? :INITiate:MODE:CONTinuous :INITiate:MODE:SINGle :INITiate[:IMMediate] :CONFigure? :TRIGger[:SEQuence][:STATe] ON OFF 1 0 :TRIGger[:SEQuence][:STATe]? :TRIGger[:SEQuence]:SOURce EXTernal[1] IMMediate WIF RFBurst SG :TRIGger[:SEQuence]:SOURce? :TRIGger[:SEQuence]:SLOPe POSitive NEGative :TRIGger[:SEQuence]:SLOPe? :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute <ampl> :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute? :TRIGger[:SEQuence]:DELay <time> :TRIGger[:SEQuence]:DELay? Note: The trigger settings are separately retained for each application, and are commonly applied to the measurement functions within the application. In other words, if the trigger is set by the signal analyzer, the same trigger setting is applied to all the measurement functions of the signal analyzer. The same applies to the spectrum analyzer. 2-32
57 2.5 Common Measurement Measurement and control :INITiate:CONTinuous OFF ON 0 1 Continuous Measurement This command sets continuous or single measurement mode. 2 Details :INITiate:CONTinuous <switch> <switch> 0 OFF 1 ON Measurement mode Continuous measurement mode (Default) Continuous measurement mode When ON is set, continuous measurement starts. When set to Off, the Single measurement mode is set but measurement does not start at that time. To make a continuous measurement. INIT:CONT ON SCPI Device Message Details :INITiate:CONTinuous? Continuous Measurement This command queries the measurement mode. :INITiate:CONTinuous? <switch> <switch> Measurement mode 0 Single measurement mode 1 Continuous measurement mode To query the measurement mode. INIT:CONT? >
58 Chapter 2 SCPI Device Message Details :INITiate:MODE:CONTinuous Continuous Measurement This command sets continuous or single measurement mode. :INITiate:MODE:CONTinuous To start continuous measurement. INIT:MODE:CONT :INITiate:MODE:SINGle Single Measurement This command starts single measurement. :INITiate:MODE:SINGle To start a single measurement. INIT:MODE:SING :INITiate[:IMMediate] Initiate Measurement starts with the current measurement mode. :INITiate[:IMMediate] To start measurement INIT 2-34
59 2.5 Common Measurement :CONFigure? Configure This command queries the name of the current measurement mode. :CONFigure? 2 <mode> <mode> BT Measurement function This application To query the current measurement function. CONF? > BT SCPI Device Message Details Trigger Switch :TRIGger[:SEQuence][:STATe] OFF ON 0 1 Trigger Switch This command sets the trigger wait state On/Off. :TRIGger[:SEQuence][:STATe] <switch> <switch> OFF 0 ON 1 To set the trigger wait state to On. TRIG ON Trigger wait state On/Off Off (Default) On 2-35
60 Chapter 2 SCPI Device Message Details :TRIGger[:SEQuence][:STATe]? Trigger Switch This command queries the trigger wait state On/Off. :TRIGger[:SEQuence][:STATe]? <switch> <switch> Trigger wait state On/Off 0 Off 1 On To query the trigger wait state setting. TRIG? > Trigger source :TRIGger[:SEQuence]:SOURce EXTernal[1] IMMediate WIF RFBurst SG Trigger Source Details This command selects the trigger signal source. :TRIGger[:SEQuence]:SOURce <mode> <mode> EXTernal[1] IMMediate WIF RFBurst SG Trigger signal source External input (External) Free run (Default) Wideband IF detection (Wide IF Video) SG Marker (SG Marker) SG marker can be selected only when the Option 020 is installed. To set the trigger signal source to External input. TRIG:SOUR EXT 2-36
61 2.5 Common Measurement :TRIGger[:SEQuence]:SOURce? Trigger Source This command queries the trigger signal source. :TRIGger[:SEQuence]:SOURce? 2 Details <mode> <mode> Trigger signal source EXT External input (External) IMM Free run WIF Wideband IF detection (Wide IF Video) SG SG Marker (SG Marker) SG marker can be selected only when the Option 020 is installed. SCPI Device Message Details To query the trigger signal source. TRIG:SOUR? > EXT 2-37
62 Chapter 2 SCPI Device Message Details Trigger Slope :TRIGger[:SEQuence]:SLOPe POSitive NEGative Trigger Slope This command sets the trigger detection mode (rising or falling). :TRIGger[:SEQuence]:SLOPe <mode> <mode> POSitive NEGative To detect a trigger at the rising edge. TRIG:SLOP POS Trigger detection mode Detects a trigger at the rising edge (Default). Detects a trigger at the falling edge. :TRIGger[:SEQuence]:SLOPe? Trigger Slope This command queries the trigger detection mode (rising or falling). :TRIGger[:SEQuence]:SLOPe? <mode> <mode> POS NEG To query the trigger detection mode. TRIG:SLOP? > POS Trigger detection mode Detects a trigger at the rising edge. Detects a trigger at the falling edge. 2-38
63 2.5 Common Measurement :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute <ampl> Wide IF Trigger Level This command sets the threshold value of the level at which trigger sweep starts in the Wide IF Video trigger. 2 :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute <ampl> <ampl> Threshold value of the level at which trigger sweep starts Range 60 to 50 dbm Resolution 1 dbm Default 20 dbm To set the threshold value of the level at which trigger sweep starts to 10 dbm TRIG:WIF:LEV:ABS 10 SCPI Device Message Details 2-39
64 Chapter 2 SCPI Device Message Details :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute? Wide IF Trigger Level This command queries the threshold value of the level at which trigger sweep starts in the Wide IF Video trigger. :TRIGger[:SEQuence]:WIF :RFBurst:LEVel:ABSolute? <level> <level> Threshold value of the level at which trigger sweep starts Range 60 to 50 dbm Resolution 1 db Suffix code None, value is returned in dbm units. To query the threshold value of the level at which trigger sweep starts TRIG:WIF:LEV:ABS? > 10 :TRIGger[:SEQuence]:DELay <time> Trigger Delay Paramete This command sets the delay time from generation of a trigger to start of the capture operation. :TRIGger[:SEQuence]:DELay <time> <time> Delay time from generation of trigger to start of capture Range 2 to 2 s Resolution 20 nanoseconds Suffix code NS,US,MS,S s is used when omitted. Default 0 s To set the trigger delay time to 20 ms. TRIG:DEL 20MS 2-40
65 2.5 Common Measurement :TRIGger[:SEQuence]:DELay? Trigger Delay This command queries the delay time from generation of a trigger to start of the capture operation. 2 :TRIGger[:SEQuence]:DELay? <time> <time> Delay time from generation of trigger to start of capture Range 2 to +2 s Resolution 20 nanoseconds Value is returned in s units. To query the delay time. TRIG:DEL? > SCPI Device Message Details 2-41
66 Chapter 2 SCPI Device Message Details 2.6 Measurement This section explains the device messages that pertains to measurement function. Table lists device messages to execute measurement and to query the result. Table Device Messages for Measurement s Configure Initiate Fetch Read/Measure Device Message :CONFigure:BT :INITiate:BT :FETCh:BT[n]? :READ:BT[n]? :MEASure:BT[n]? Table lists the responses to parameter [n] of the device messages in Table Table s to Measurement Results n Result Mode 1 or omitted A/B s are returned with comma-separated value formats in the following order: 1 GFSK Power Avg (Average) (dbm) 2 GFSK Power Avg (max) (dbm) 3 GFSK Power Avg (min) (dbm) 4 GFSK Power Peak (dbm) 5 Pass/Fail flag of GFSK Power Avg (max/min) 6 Pass/Fail flag of GFSK Power Peak 7 Count of Output Power Measurements 8 Delta f1 Avg (Average) (Hz) 9 Delta f1 Avg (max) (Hz) 10 Delta f1 Avg (min) (Hz) 11 Delta f2 Avg (Hz) 12 Delta f1 Max (max) (Hz) 13 Delta f1 Max (min) (Hz) 14 Delta f2 Max (max) (Hz) 15 Delta f2 Max (min) (Hz) 16 Delta f2 Max > Lower Limit (%) 17 Delta f2 Avg/Delta f1 Avg 18 Pass/Fail flag of Delta f1 Avg (Average) 19 Pass/Fail flag of Delta f1 Avg (Max/Min) 20 Pass/Fail flag of Delta f2 Max > Lower Limit 21 Pass/Fail flag of Delta f2 Avg/Delta f1 Avg 2-42
MX269028A WLAN (802.11) Measurement Software Operation Manual Remote Control. Third Edition
MX269028A WLAN (802.11) Measurement Software Operation Manual Remote Control Third Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional
More informationMX269017A Vector Modulation Analysis Software Operation Manual Remote Control
MX269017A Vector Modulation Analysis Software Operation Manual Remote Control 24th Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional
More informationMX269020A LTE Downlink Measurement Software Operation Manual Remote Control. 24th Edition
MX269020A LTE Downlink Measurement Software Operation Manual Remote Control 24th Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety
More informationMX269013A GSM/EDGE Measurement Software Operation Manual Operation. Eighth Edition
MX269013A GSM/EDGE Measurement Software Operation Manual Operation Eighth Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety and
More informationMX285051A-001 Pre-Standard CP-OFDM Downlink MX285051A-051 Pre-Standard CP-OFDM Uplink Operation Manual Operation. Second Edition
MX285051A-001 Pre-Standard CP-OFDM Downlink MX285051A-051 Pre-Standard CP-OFDM Uplink Operation Manual Operation Second Edition For safety and warning information, please read this manual before attempting
More informationMX269017A Vector Modulation Analysis Software Operation Manual Operation
MX269017A Vector Modulation Analysis Software Operation Manual Operation 27th Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety
More informationLadyBug LB5900 Programmatic Measurement Commands and Examples
Contents Section I Programmatic Measurements Overview... 2 General... 2 Document Notice... 2 Zeroing and Calibration... 2 Sensing Range... 2 Section II - Non-Triggered Measurements... 3 READ? (Non-Triggered)...
More informationPower Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master
Measurement Guide Power Meter for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master Power Meter Option 29 High Accuracy Power Meter Option 19 Inline Peak
More informationMX269012A W-CDMA/HSPA Uplink Measurement Software Operation Manual Operation
MX269012A W-CDMA/HSPA Uplink Measurement Software Operation Manual Operation Seventh Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional
More informationMX269022A LTE TDD Downlink Measurement Software Operation Manual Operation. 18th Edition
MX269022A LTE TDD Downlink Measurement Software Operation Manual Operation 18th Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety
More informationSignal Generators for Anritsu RF and Microwave Handheld Instruments
Measurement Guide Signal Generators for Anritsu RF and Microwave Handheld Instruments BTS Master Spectrum Master Tracking Generator Option 20 Vector signal Generator Option 23 Anritsu Company 490 Jarvis
More informationTETRA Tx Test Solution
Product Introduction TETRA Tx Test Solution Signal Analyzer Reference Specifications ETSI EN 300 394-1 V3.3.1(2015-04) / Part1: Radio ETSI TS 100 392-2 V3.6.1(2013-05) / Part2: Air Interface May. 2016
More informationR&S FS-K9 Measurements with Power Sensors
Test and Measurement Software Manual PAD-T-M: 3574.3259.02/01.00/CI/1/EN R&S FS-K9 Measurements with Power Sensors Software Manual 1157.3029.42 05 2014 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671
More informationHP 33120A Function Generator / Arbitrary Waveform Generator
Note: Unless otherwise indicated, this manual applies to all Serial Numbers. The HP 33120A is a high-performance 15 MHz synthesized function generator with built-in arbitrary waveform capability. Its combination
More informationMX368033A CDMA2000 1xEV-DO Signal Generation Software Operation Manual (For MU368030A)
MX368033A CDMA2000 1xEV-DO Signal Generation Software Operation Manual (For MU368030A) Second Edition Read this manual before using the equipment. To ensure that the equipment is used safely, read the
More informationMS2830A Signal Analyzer Operation Manual Analog Radio Automatic Measurement Software
MS2830A Signal Analyzer Operation Manual Analog Radio Automatic Measurement Software Second Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional
More informationISA-30/80/132/265 Spectrum Analyzer Phase Noise Manual Ver 1.0. Read this manual before using the equipment. Keep this manual with the equipment
ISA-30/80/132/265 Spectrum Analyzer Phase Noise Manual Ver 1.0 Read this manual before using the equipment. Keep this manual with the equipment TABLE OF CONTENTS SECTION 1 GENERAL --------------------------------------------
More informationAgilent 33250A 80 MHz Function / Arbitrary Waveform Generator. User s Guide
User s Guide Publication Number 33250-90002 (order as 33250-90100 manual set) Edition 2, March 2003 Copyright Agilent Technologies, Inc. 2000, 2003 For Safety information, Warranties, and Regulatory information,
More informationAgilent 33220A. 20 MHz Waveform Generator. User's Guide. Agilent Technologies
Agilent 33220A 20 MHz Waveform Generator User's Guide Agilent Technologies User s Guide Publication Number 33220-90002 (order as 33220-90100 manual set) Edition 4, May 2007 Copyright 2003, 2005, 2007 Agilent
More informationMX368012A GSM Device Test Software Operation Manual
MX368012A GSM Device Test Software Operation Manual Fourth Edition To ensure that the equipment is used safely, read the "For Safety" in the MG3681A Digital Modulation Signal Generator Operation Manual
More informationAgilent 33210A 10 MHz Function / Arbitrary Waveform Generator. User s Guide
User s Guide Publication Number 33210-90001 (order as 33210-90000 manual set) Edition 1, August 2008 Copyright 2008 Agilent Technologies, Inc. Agilent 33210A 10 MHz Function / Arbitrary Waveform Generator
More informationKey Reference. Agilent Technologies E8257D/67D PSG Signal Generators. Manufacturing Part Number: E Printed in USA July 2007
Agilent Technologies E8257D/67D PSG Signal Generators This guide applies to the following signal generator models: E8267D PSG Vector Signal Generator E8257D PSG Analog Signal Generator Due to our continuing
More informationProgramming Guide SSA3000X Series Spectrum Analyzer PG0703X-E02A
Programming Guide SSA3000X Series Spectrum Analyzer PG0703X-E02A 2015 SIGLENT TECHNOLOGIES CO., LTD Contents 1. Programming Overview... 3 1.1 Build Communication... 3 1.2 Remote Control Capabilities...
More informationSDI SPECTRADYNAMICS, INC GHZ RUBIDIUM FREQUENCY SYNTHESIZER OPERATING MANUAL
SPECTRADYNAMICS, INC. 6.834 GHZ RUBIDIUM FREQUENCY SYNTHESIZER RB-1 OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com
More informationMS2650/MS2660B/C Series Spectrum Analyzer Operation Manual. Vol. 2 (Detailed Operating Instructions) 10th Edition
MS2650/MS2660B/C Series Spectrum Analyzer Operation Manual Vol. 2 (Detailed Operating Instructions) 10th Edition For safety and warning information, please read this manual before attempting to use the
More informationWIDEBAND MICROWAVE SIGNAL GENERATOR. SG24000H Compact, Low Phase-Noise, Wideband. Signal Generator Control
DS Instruments Key Features: 0.1 to 24GHz Coverage 25 Output Step Attenuator 20 Vernier Range D text S SG24000H WIDEBAND MICROWAVE SIGNAL GENERATOR Tiny Frequency Step Size Sub-Harmonic Filtering Very
More informationSuitable firmware can be found on Anritsu's web site under the instrument library listings.
General Caution Please use a USB Memory Stick for firmware updates. Suitable firmware can be found on Anritsu's web site under the instrument library listings. If your existing firmware is older than v1.19,
More informationDigital Wireless Measurement Solution
Product Introduction Digital Wireless Measurement Solution Signal Analyzer MS2690A/MS2691A/MS2692A/MS2840A/MS2830A Vector Modulation Analysis Software MX269017A Vector Signal Generator MS269xA-020, MS2840A-020/021,
More informationAgilent N7509A Waveform Generation Toolbox Application Program
Agilent N7509A Waveform Generation Toolbox Application Program User s Guide Second edition, April 2005 Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced
More informationR3267 Series OPT63 GSM/DECT Measurement Option Operation Manual
Cover R3267 Series OPT63 GSM/DECT Measurement Option Operation Manual MANUAL NUMBER FOE-8335241F00 Applicable models R3264 R3267 R3273 C 1999 ADVANTEST CORPORATION All rights reserved. First printing Jun
More informationR3267 Series OPT64 PDC/PHS/IS-136 Measurement Option Operation Manual
Cover R3267 Series OPT64 PDC/PHS/IS-136 Measurement Option Operation Manual MANUAL NUMBER FOE-8335220F00 Applicable models R3264 R3267 R3273 C 1999 ADVANTEST CORPORATION First printing April 20, 1999 All
More informationDEPARTMENT OF THE ARMY TECHNICAL BULLETIN
*TB 9-6625-2333-24 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR SPECTRUM ANALYZER AGILENT MODELS 8562EC AND 8562EC-104 Headquarters, Department of the Army, Washington, DC 17 June
More informationDSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.
FAQ Instrument Solution FAQ Solution Title DSA-815 Demo Guide Date:08.29.2012 Solution: The DSA 800 series of spectrum analyzers are packed with features. Spectrum analyzers are similar to oscilloscopes..
More informationKey Reference. Agilent Technologies E8663B Analog Signal Generator
Agilent Technologies E8663B Analog Signal Generator For the latest revision of this guide, go to http://www.agilent.com/find/e8663b and click Product Library. Manufacturing Part Number: E8663-90004 Printed
More informationSite Master Cable and Antenna Analyzer with Spectrum Analyzer
Maintenance Manual Site Master Cable and Antenna Analyzer with Spectrum Analyzer S331E, 2 MHz to 4 GHz S332E, 2 MHz to 4 GHz, Spectrum Analyzer, 100 khz to 4 GHz S361E, 2 MHz to 6 GHz S362E, 2 MHz to 6
More informationModel 855 RF / Microwave Signal Generator
Features Very low phase noise Fast switching Phase coherent switching option 2 to 8 phase coherent outputs USB, LAN, GPIB interfaces Applications Radar simulation Quantum computing High volume automated
More informationMS2711B Hand-Held Spectrum Analyzer
MS2711B Hand-Held Spectrum Analyzer Programming Manual Hand-Held Spectrum Analyzer, for Measuring, Monitoring and Analyzing Signal Environments WARRANTY The Anritsu product(s) listed on the title page
More informationModel 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-M Specification 1.8 BNC
Specification 1.8 Model 745 Series 0.01-20.0 GHz Low Phase Noise Synthesizer 250 fs Digital Delay Generator Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 Introduction The
More informationRIGOL. User s Guide. DSA1000 Series Spectrum Analyzer. May RIGOL Technologies, Inc.
User s Guide DSA1000 Series Spectrum Analyzer May 2012 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered
More informationRIGOL. User s Guide. DSA1000A Series Spectrum Analyzer. Jul RIGOL Technologies, Inc.
User s Guide DSA1000A Series Spectrum Analyzer Jul. 2013 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a
More information7. FREQUENCY SEPARATION
7. FREQUENCY SEPARATION 7.1. Limits According to FCC Section 15.247(a)(1), Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 khz or two-thirds of the
More informationRIGOL. User s Guide. DSA1000A Series Spectrum Analyzer. July RIGOL Technologies, Inc.
User s Guide DSA1000A Series Spectrum Analyzer July 2011 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a
More informationMX370110A/MX269910A LTE TDD IQproducer Operation Manual
MX370110A/MX269910A LTE TDD IQproducer Operation Manual Eighth Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety and warning
More informationAN12165 QN908x RF Evaluation Test Guide
Rev. 1 May 2018 Application note Document information Info Keywords Abstract Content GFSK, BLE, RF, Tx power, modulation characteristics, frequency offset and drift, frequency deviation, sensitivity, C/I
More informationDevelopment of MT8870A Universal Wireless Test Set
Makoto Nishizawa, Yasunori Yamada, Mamoru Iwamoto [Summary] Smartphones, tablet computers, and similar devices can support a variety of wireless systems, such as a cellular, wireless LAN, Bluetooth, GPS,
More informationWT3000 Manual, Vol 3/3 WT3000. Precision Power Analyzer Expansion Function. IM E 7th Edition
WT3000 Manual, Vol 3/3 WT3000 Precision Power Analyzer Expansion Function 7th Edition Thank you for purchasing the WT3000 Precision Power Analyzer. This Expansion Function User s Manual contains useful
More informationPORTABLE WIDEBAND RF SIGNAL GENERATOR
DS Instruments -Key Features- 25 to 6000MHz Coverage Calibrated RF Power Output SG6000L R11 PORTABLE WIDEBAND RF SIGNAL GENERATOR 31 RF Output Step Attenuator 20 Vernier Range USB COM Interface Industry
More informationR&S SMB100N SIGNAL GENERATOR
R&S SMB100N SIGNAL GENERATOR PERFORMANCE SPECIFICATIONS VERSION 02.00, SEPTEMBER 2009 CONTENTS Specifications...3 Definitions... 3 RF performance... 4 Frequency... 4 Frequency sweep... 4 Reference frequency...
More informationRIGOL. User s Guide. DSA1000 Series Spectrum Analyzer. Jan RIGOL Technologies, Inc.
User s Guide DSA1000 Series Spectrum Analyzer Jan. 2010 RIGOL Technologies, Inc. Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is registered trademark of RIGOL
More informationIX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x
IX000693 Feb. 015 Operation Guide Sequence Creation and Control Software SD011-PCR-LE Wavy for PCR-LE Ver. 5.5x About This Guide This PDF version of the operation guide is provided so that you can print
More informationProgramming Guide SSA3000X Series Spectrum Analyzer PG0703X-E03D
Programming Guide SSA3000X Series Spectrum Analyzer PG0703X-E03D 2017 SIGLENT TECHNOLOGIES CO., LTD Contents 1. Programming Overview... 3 1.1 Build Communication... 3 1.2 Remote Control Capabilities...
More informationME1000 RF Circuit Design. Lab 1. Calibration with Spectrum Analyzer
ME1000 RF Circuit Design Lab 1 Calibration with Spectrum Analyzer This courseware product contains scholarly and technical information and is protected by copyright laws and international treaties. No
More informationModel 865 RF / Ultra Low Noise Microwave Signal Generator
Model 865 RF / Ultra Low Noise Microwave Signal Generator Features Excellent signal purity: ultra-low phase noise and low spurious Combination of highest output power and fastest switching Powerful touch-display
More informationKeysight 33210A 10 MHz Function/Arbitrary Waveform Generator
Keysight 33210A 10 MHz Function/Arbitrary Waveform Generator Service Guide Keysight 33210A at a Glance The Keysight Technologies 33210A is a 10 MHz synthesized function generator with built-in arbitrary
More informationUser s Guide. P-Series Power Meters. Compatibility with the 8480 and E-series sensors will be available in a future Firmware release.
User s Guide P-Series Power Meters Compatibility with the 8480 and E-series sensors will be available in a future Firmware release. N1911A and N1912A Manufacturing Part Number: N1912-90002 Printed in UK
More informationSapphire Reference Manual V1.4. An RF tester for the Bluetooth 5 LE standard, compatible with TLF3000.
Sapphire Reference Manual V1.4 An RF tester for the Bluetooth 5 LE standard, compatible with TLF3000. June 14, 2017 1 Contents 1 Contents... 2 2 Overview.... 8 3 Control.... 9 3.1 Overview... 9 3.2 Native
More informationTC-3000C Bluetooth Tester
TC-3000C Bluetooth Tester Product Instructions TC-3000C Bluetooth Tester is able to analyze the data of every packet that is transmitted to the upper application protocol layer using the protocol stack,
More informationModel 865-M Wideband Synthesizer
Model 865-M Wideband Synthesizer Features Wideband Low phase noise Fast switching down to 15 µs FM, Chirps, Pulse Internal OCXO, external variable reference Single DC supply Applications ATE LO for frequency
More informationProgramming Manal. Bit Master MP1026A Eye Pattern Analyzer
Programming Manal Bit Master MP1026A Eye Pattern Analyzer Bit Master MP1026A Programming Manual Document # Table of Contents 1 Introduction... 4 Scope of this Manual... 4 References... 4 Trademark Acknowledgments...
More informationModel 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC
Model 845-HP Datasheet Model 745 Series Portable 20+ GHz Microwave Signal Generator High Power +23dBM Power Output 250 fs Digital Delay Generator BNC Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation
More information8800SX TETRA Base Station Operation
8800SX TETRA Base Station Operation 8800SX TETRA Base Station Test The 8800SX TETRA Base Station Test option utilizes the ETSI standard defined TETRA T1 test mode. - ETSI is the European Telecommunications
More informationExternal Source Control
External Source Control X-Series Signal Analyzers Option ESC DEMO GUIDE Introduction External source control for X-Series signal analyzers (Option ESC) allows the Keysight PXA, MXA, EXA, and CXA to control
More informationPN9000 PULSED CARRIER MEASUREMENTS
The specialist of Phase noise Measurements PN9000 PULSED CARRIER MEASUREMENTS Carrier frequency: 2.7 GHz - PRF: 5 khz Duty cycle: 1% Page 1 / 12 Introduction When measuring a pulse modulated signal the
More informationModel 845-M Low Noise Synthesizer
Model 845-M Low Noise Synthesizer Features Low phase noise Fast switching down to 20 µs FM, Chirps, Pulse Internal OCXO, external variable reference Single DC supply Applications ATE LO for frequency converters
More information2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit
Preliminary Technical Datasheet 2400C Series Microwave Signal Generators 10 MHz to 40 GHz Low Phase Noise and Fast-Switching Speed in a Single Unit 2400C Series Microwave Signal Generator Signal Generator
More informationAPPLy commands Command Parameters Definition. [<frequency>] [<amplitude>] [<offset>] [<amplitude>] [<offset>] [<amplitude DEF>] [<offset>]
Table A-5: Standard Event register Bit Decimal value Description 5 32 Command syntax error exists. 6 64 Not used (always 0). 7 128 Power has been turned off and on. Event register is cleared. NOTE The
More informationAgilent Technologies. E8257D/67D, E8663D PSG Signal Generators. Key Reference. Agilent Technologies
Agilent Technologies E8257D/67D, E8663D PSG Signal Generators Key Reference Agilent Technologies Notices Agilent Technologies, Inc. 2006-2010 No part of this manual may be reproduced in any form or by
More informationKey and Data Field Reference Volume 1: Symbols, Numerics, A-H
Key and Data Field Reference Volume 1: Symbols, Numerics, A-H Agilent Technologies E4428C/38C ESG Signal Generators This guide applies to the following signal generator models: E4428C ESG Analog Signal
More informationAirScope Spectrum Analyzer User s Manual
AirScope Spectrum Analyzer Manual Revision 1.0 October 2017 ESTeem Industrial Wireless Solutions Author: Date: Name: Eric P. Marske Title: Product Manager Approved by: Date: Name: Michael Eller Title:
More information3GPP2 Signal Analyzer
Measurement Guide 3GPP2 Signal Analyzer for Anritsu RF and Microwave Handheld Instruments BTS Master, Cell Master, Spectrum Master RF Demod OTA CDMA Option 42 Option 43 Option 33 EV-DO Option 62 Option
More informationKeysight Technologies N9051B Pulse Measurement Software X-Series Signal Analyzers. Technical Overview
Keysight Technologies N9051B Pulse Measurement Software X-Series Signal Analyzers Technical Overview 02 Keysight N9051B Pulse Measurement Software X-Series Signal Analyzers - Technical Overview Features
More informationRadio Frequency. Core System Package Part A. Test Suite Structure (TSS) and Test Purposes (TP) System Specification 1.2/2.0/2.
Core System Package Part A Test Suite Structure (TSS) and Test Purposes (TP) System Specification 1.2/2.0/2.0 + EDR This document defines the TSS and TP for qualification testing of the Bluetooth Wireless
More information15. Specifications WF1947/WF
15. Specifications 15.1 Oscillation Mode...15-2 15.2 Waveform...15-2 15.3 Frequency, Phase...15-3 15.4 Output Characteristics...15-3 15.5 Signal Characteristics...15-5 15.6 Modulated Oscillation Mode...15-7
More information4 Instrument Functions
RF Frequency 4 Instrument Functions This chapter describes the functions of the instrument and its options which can be activated manually via menus or by remote control (frequency and level settings,
More informationAgilent 33220A. 20 MHz Waveform Generator. Service Guide. Agilent Technologies
Agilent 33220A 20 MHz Waveform Generator Service Guide Agilent Technologies Service Guide Publication Number 33220-90012 (order as 33220-90100 manual set) Edition, May 2012 Copyright Agilent Technologies,
More informationApplication Note. LTE Measurement. MT8820C Radio Communication Analyzer
Application Note LTE Measurement MT8820C Radio Communication Analyzer Revision History Ver. No Date Contents Related product software version 1.00 2010/June First edition M882012C/42C Ver. 20.10 2.00 2010/August
More informationSML01 SML02 SML03 SIGNAL GENERATOR. Operating Manual Test and Measurement Division
Test and Measurement Division Operating Manual SIGNAL GENERATOR SML01 1090.3000.11 SML02 1090.3000.12 SML03 1090.3000.13 Printed in the Federal Republic of Germany 1090.3123.12-03 1 SML Tabbed Divider
More informationAgilent 33220A 20 MHz Function / Arbitrary Waveform Generator. Service Guide
Service Guide Publication Number 33220-90012 (order as 33220-90100 manual set) Edition 2, March 2005 Copyright 2003, 2005 Agilent Technologies, Inc. Agilent 33220A 20 MHz Function / Arbitrary Waveform
More informationMOBILE COMMUNICATIONS MEASURING INSTRUMENTS
DIGITAL MODULATION SIGNAL GENERATOR MG3681A 250 khz to 3 GHz GPIB For Evaluating Next Generation Digital Mobile Communications Systems The MG3681A uses a wideband vector modulator to output the highaccuracy,
More informationIVI STEP TYPES. Contents
IVI STEP TYPES Contents This document describes the set of IVI step types that TestStand provides. First, the document discusses how to use the IVI step types and how to edit IVI steps. Next, the document
More informationPULSE INPUT MODULE PI232/PI272 USER S MANUAL
UM-TS02 -E021 PROGRAMMABLE CONTROLLER PROSEC T2-series PULSE INPUT MODULE PI232/PI272 USER S MANUAL TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property damage or human
More informationR&S FSH4/8/13/20 Remote Control via LAN or USB Software Manual
R&S FSH4/8/13/20 Remote Control via LAN or USB Software Manual 1173.0089.12 23 Test & Measurement Software Manual The Software Manual describes the following R&S FSH options R&S FSH-K40 (1304.5606.02)
More informationProduct Brochure. MS2690A/MS2691A/MS2692A Signal Analyzer MS2690A: 50 Hz to 6.0 GHz MS2691A: 50 Hz to 13.5 GHz MS2692A: 50 Hz to 26.
Product Brochure MS2690A/MS2691A/MS2692A Signal Analyzer MS2690A: 50 Hz to 6.0 GHz MS2691A: 50 Hz to 13.5 GHz MS2692A: 50 Hz to 26.5 GHz The Signal Analyzer MS2690A/MS2691A/MS2692A (MS269xA) has the excellent
More informationSignal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Digital and RF Tester with 1 GHz Range. Key Features
Signal Forge TM Signal Forge 1000 TM Synthesized Signal Generator L 8.5 W 5.4 H 1.5 Digital and RF Tester with 1 GHz Range The Signal Forge 1000 combines a 1 GHz frequency range with three dedicated outputs
More informationSPM-50 RF Spectrum Power Meter PC Software User Manual
SPM-50 RF Spectrum Power Meter PC Software User Manual Shineway Technologies, Inc. Notices Copyright 2014, ShinewayTech, All rights reserved. No part of this manual may be reproduced in any form or by
More informationSignal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Flexible Design Enables Testing of RF and Clock-driven Systems.
Signal Forge TM Signal Forge 1000 TM Synthesized Signal Generator L 8.5 W 5.4 H 1.5 Flexible Design Enables Testing of RF and Clock-driven Systems The Signal Forge 1000 combines a 1 GHz frequency range
More informationInstrument Messages and Functional Tests
Instrument Messages and Functional Tests Agilent CSA Spectrum Analyzer This manual provides documentation for the following instruments: N1996A-503 (100 khz to 3 GHz) N1996A-506 (100 khz to 6 GHz) Manufacturing
More information1 Radar calibration at first installation
1 Radar calibration at first installation At first installation is necessary to properly calibrate the radar. This includes: Heading Line Transmission Trigger Delay Antenna Parking Position (only MDS 9
More informationR&S ZVH Remote Control via LAN or USB Software Manual
R&S ZVH Remote Control via LAN or USB Software Manual 1173.9005.12 08 Test & Measurement Software Manual The Software Manual describes the following R&S ZVH models and options R&S ZVH-K40 (1309.7013.02)
More informationGM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide
GM8036 Laser Sweep Optical Spectrum Analyzer Programming Guide Notices This document contains UC INSTRUMENTS CORP. proprietary information that is protected by copyright. All rights are reserved. This
More informationTEST REPORT FCC ID: 2ADMF-HC06. : bluetooth module keyes HC-06, keyes hc-05, FUNDUINO HC-06, FUNDUINO hc-05
Shenzhen Certification Technology Service Co., Ltd. 2F, Building B, East Area of Nanchang Second Industrial Zone, Gushu 2 nd Road, Bao'an District, Shenzhen 518126, P.R. China TEST REPORT FCC ID: 2ADMF-HC06
More informationLS3300 AC Power Calibrator Simple Adjustment Procedure for Voltage, Current, and Frequency
User s Manual AC Power Calibrator Simple Adjustment Procedure for Voltage, Current, and Frequency The instrument should be adjusted by a qualified engineer at a qualified facility with sufficient precision.
More informationHP 16533A 1-GSa/s and HP 16534A 2-GSa/s Digitizing Oscilloscope
User s Reference Publication Number 16534-97009 February 1999 For Safety Information, Warranties, and Regulatory Information, see the pages behind the Index Copyright Hewlett-Packard Company 1991 1999
More informationFREQUENCY SYNTHESIZERS, SIGNAL GENERATORS
SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And
More informationAgilent Maximizing Measurement Speed Using P-Series Power Meters
Agilent Maximizing Measurement Speed Using P-Series Power Meters Application Note A winning solution in the combination of bandwidth and performance 30 MHz video bandwidth Single-shot real time and repetitive
More informationOptical Spectrum Analyzer MS9740B. Product Introduction
Optical Spectrum Analyzer MS9740B Product Introduction Overview Reduce the measurement processing times by up to half compared to the earlier model while assuring high performance and complete test menus
More informationTV SIGNAL LEVEL METER USER MANUAL
TV SIGNAL LEVEL METER USER MANUAL - 0 - 1. Overview (1) (1) RF input (2) (3) A D E B C (2) Speaker (3) LCD display (4) Charger indicator (5) RS232 communication port (6) DC-IN port F G A. The battery icon
More informationSignal Analyzer MS2840A
Product Brochure Signal Analyzer MS2840A MS2840A-040: 9 khz to 3.6 GHz MS2840A-041: 9 khz to 6.0 GHz «MS2840A-044: 9 khz to 26.5 GHz *» «MS2840A-046: 9 khz to 44.5 GHz *» *: Refer to the separate brochure
More information2026Q CDMA/GSM Interferer MultiSource Generator
Signal Sources 2026Q CDMA/GSM Interferer MultiSource Generator The 2026Q is designed to work with a radio test set to provide a fully integrated radio receiver test solution for cellular and PCS systems
More informationModel MHz Arbitrary Waveform Generator Specifications
50MHz Arbitrary Waveform Generator s DISPLAY: Graph mode for visual verification of signal settings. CAPABILITY: Standard waveforms: Sine, Square, Ramp, Triangle, Pulse, Noise, DC Built-in arbitrary waveforms:
More information