Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in highdensity cabinets.
|
|
- Arnold Gregory
- 6 years ago
- Views:
Transcription
1 ST V-2001C The Server Technology Metered PDU provides reliable power distribution with local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. Ke y F e at ur e s A ut o - Fl i p C ur r e nt Di s pl a y Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in highdensity cabinets. "Metered" Br a nc h C i r c ui t P r o t e c t i o n This PDU meets the UL and IEC requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses. Hi g h Re t e nt i o n Lo c ki ng Out l e t s Receptacles have high retention and are compatible with P- Lock type power cords. Hi g h T e mpe r a t ur e Ra t i ng This product has been tested and approved for safe and reliable operation in 60 C data center environments. P o we r P i vo t The 90 degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed. Fl e xi bl e Mo unt i ng Includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details). C o l o r Ide nt i f i c a t i o n C o l o r Ide nt i f i c a t i o n Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.
2 I nput s Input Voltage (V): 208 Input Plug: NEMA L6-30P Input Current (A): 30 Input Current Rated (A): 24 Input Power Capacity (kw): 5.0 Out put s Connect or Rat ing (24) x IEC 60320/C13 North American Rating: L-L (15A Peak) (6) x IEC 60320/C19 North American Rating: L-L (20A Peak) Br anch Ci r cui t P r ot e ct i on UL498 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: 16A, 5 kaic Interrupt Rating P hys i cal Dimensions: 60.0in tall x 1.75in wide x 2.25in deep [1524mm x 45mm x 58mm] Envi r onme nt al Oper at ing Envir onment : 32 F to 140 F / 0 C to 60 C 8%RH to 90%RH non-condensing 6,500ft/2km elevation S t or age Envir onment : -40 F to 185 F / -40 C to 85 C 8%RH to 90%RH non-condensing 50,000ft/15km elevation Quiescent / Unloaded Power Draw: < 10W for all configurations Communi cat i ons & Se cur i t y Not Applicable Ce r t i f i cat i ons Nor t h Amer ican: ctuvus Mark to UL :2007 R10.14 CAN/CSA-C22.2 No A1:2011+A2:2014 FCC Part 15 Subpart B Sections and , Class A M e as ur e me nt Accur acy Input Meas ur ement Accur acy: LED Current = ± 10% at 0.1 amp ( amps) and 1 amp (> 9.9 amps) resolution
3 Opt i onal Acce s s or i e s Mounting Brackets - Buttons (KIT-0020) included for tool-less mounting (see diagram) - See the Mounting Bracket Guide for further suggestions - Custom mounting options available. Contact your local Server Technology representative Cable Retention Devices for non-locking cords - EZip - Cable Sleeve
4 Dr awi ng s
5 Addi t i onal I nf or mat i on Warrantr ant y: Server Technology offers a standard 2-year limited parts & labor warranty. Extended support is available at the time of purchase. See the Support Options on the website, or contact your local Server Technology representative for more information. Pat ent s : Information on Server Technology patents is available on the website at: HDOT, PIPS, POPS, CDU, Sentry, Server Technology, the ST Eye logo, and the globe logo are U.S. registered trademarks of Server Technology, Inc. Power Pivot, EZip, StartUp Stick and PRO2 are trademarks of Server Technology, Inc. Information in this document is current as of time of publishing. Contact your Server Technology representative for the most up-to-date information Server Technology, Inc. 1 Cisco EnergyWise is a U.S. registered trademark of Cisco Technology, Inc. 2 VMware and VMware Ready is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. 3 Global models are typically for use in countries outside of North America. Contact your Server Technology representative for more information about which models are appropriate for your application. This datasheet was generated on: 2-Apr-2018
Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and notifications.
ST V-3 101C ( M as t e r ) S EV-3101C (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase basis while
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C1W 16VS-1AF A17A5 ( M as t e r ) C1X16VS -1AFA17A5 (Link) The Server Technology Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationMaster and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and notifications.
CW G-24 V2C4 15 C1 ( M as t e r ) CXG-24 V2C4 15C1 (Link) The Server Technology Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
CS-15 H Y Y 4 5 4 C3-013 The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase basis while installing equipment
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
CS-24 VY -L3 0M A ( M as t e r ) CL-24 VY-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
CW -8 H 2C4 13 ( M as t e r ) CX-8H2C4 13 (Link) The Server Technology Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
ST V-65 09Z ( M as t e r ) S EV-6509Z (Link) The Server Technology PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
CS-12H D2C4 5 4 A3 ( M as t e r ) CL-12HD2C4 54 A3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
ST V-3 5 3 1C ( M as t e r ) S EV-3531C (Link) The Server Technology PRO1 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
ST V-4 5 03 D ( M as t e r ) S EV-4 503D (Link) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe
More informationMaster and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and notifications.
ST V-3 104 K ( M as t e r ) S EV-3104 K (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase basis
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
CS3 6CA-Y QM E2766 ( M as t e r ) CL36CA-YQME2766 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
CS-24 V4 -P 3 2M A ( M as t e r ) CL-24 V4 -P32MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase
More informationMaster and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and notifications.
CSG-24 VEK4 15 A1 ( M as t e r ) CLG-24 VEK4 15A1 (Link) The Server Technology Smart POPS PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2W 3 6CE-DCM F AM 00 ( M as t e r ) C2X36CE-DCMFAM00 (Link) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2W 4 2CE-2CAF 2M 00 ( M as t e r ) C2X4 2CE-2CAF2M00 (Link) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2SG3 6CE-Y QM E2M 66 ( M as t e r ) C2LG36CE-YQME2M66 (Link) The Server Technology PRO2 Smart POPS PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C1W 16VS-2CF A17AC ( M as t e r ) C1X16VS -2CFA17AC (Link) The Server Technology PRO1 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2S4 2CE-2CAF 2M 00 ( M as t e r ) C2L4 2CE-2CAF2M00 (Link) The Server Technology PRO2 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2W G24 BN-Y CLN5 D0 ( M as t e r ) C2XG24 BN-YCLN5D0 (Link) The Server Technology PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
ST V-65 4 1K ( M as t e r ) S EV-654 1K (Link) The Server Technology PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2W G3 6CE-Y QM E2M 66 ( M as t e r ) C2XG36CE-YQME2M66 (Link) The Server Technology PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel
More informationMaster and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and notifications.
CW -16VEK3 17 ( M as t e r ) CX-16VEK317 (Link) The Server Technology Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C1S3 6CA-Y QM E2766 ( M as t e r ) C1L36CA-YQME2766 (Link) The Server Technology PRO1 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2S24 H P -Y BLN5 D6 ( M as t e r ) C2L24 HP-YBLN5D6 (Link) The Server Technology PRO2 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
ST V-4 5 03 K ( M as t e r ) S EV-4 503K (Link) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
CS-26H EK4 B3 H 1 ( M as t e r ) CL-26HEK4 B3H1 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C1W 16H R-0AAA5 BAC ( M as t e r ) C1X16HR-0AAA5BAC (Link) The Server Technology PRO1 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationGain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
C2W G08 H C-0ABA2DAC ( M as t e r ) C2XG08HC-0ABA2DAC (Link) The Server Technology PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel
More informationMONITORED PRO econnect TM PDU
MONITORED PRO econnect TM PDU K E Y F E AT U R E S Continuous, automated power monitoring at each breaker and each outlet with ±1% metering accuracy Local display with an interactive screen that displays
More informationMONITORED econnect TM PDU
MONITORED econnect TM PDU K E Y F E AT U R E S Continuous, automated power monitoring at each breaker with ±1% metering accuracy Local display with an interactive screen that displays combined power measurements
More informationSWITCHED PRO econnect PDU
P R O D U C T D ATA S H E E T SWITCHED PRO econnect PDU K E Y F E AT U R E S Optimized for high density applications with a low profile design, universal tool-less mounting and use in ambient air temperatures
More informationSeaml ess Val ue and I nt egr at i on: Sony Medi a Backbone Conduct or and Di gi t al Backbone. Apr i l 2011, v2
Seaml ess Val ue and I nt egr at i on: Sony Medi a Backbone Conduct or and Di gi t al Backbone Apr i l 2011, v2 Backbone Value Proposition The technologies used to capture, process, distribute and display
More informationAdvanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CIBANO 500 3-in-1 test system for medium- and high-voltage circuit breakers Medium- and high-voltage circuit breaker
More informationPower Management Solutions. Protecting your technology investment.
Power Management Solutions Protecting your technology investment. Power Expertise and Innovation As the interconnected world of the Internet of Everything (IoE) pushes networks to the Edge for better latency
More informationPower Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL
Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL 1.01 SUMMARY: The following technical specification describes the requirements of the high accuracy standalone 3 phase Power
More information2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.
TECHNICAL SPECIFICATIONS for Single Phase, 1 to 3 KVA Power Conditioner with Regulation and Distribution Constant Power 3 (CP3) CP36508A 7/15/04 1.0 General This specification covers the electrical characteristics
More informationLIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING
LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general
More informationIm por tant Note 1. Mains Sup ply (rack units) 4 DC Power Sup ply In di ca tors (rack units) Mod ule Mod ule 7
173 & 184 Chan nel Am pli fiers Con tents In tro duc tion 1 High Pass Fil ter (re sis tor mod i fi ca tion) 1 Im por tant Note 1 In stal la tion 2 Dimensions 3 Power Re quire ments 3 Mains Sup ply (rack
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and noise allows improved low-level current measurements 3rd party safety certification 2 Requires
More informationDale Power Solutions Ltd
DC SWITCH TRIPPER CHARGER DATASHEET Features Erskine STU 110W Range 24V, 30V, or 48VDC nominal Constant voltage current limited charger output Standard alarms LCD voltmeter LED indica ons Equipped with
More informationYES 12 Charging Wall Cabinet for Mini-laptops
Built with Anthro-DNA Owner's Manual for YES 12 Charging Wall Cabinet for Mini-laptops Part # YESMLCGMPW Components at a Glance 7 1 9 8 2 4 5 11 6 10 3 Front of Cabinet (closed) 1. Locking front door to
More informationRAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL
RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External
More informationStatiVolt. Inverter UPS Systems. Features. Contents
Redundant, clean, sine-wave AC power ensures a high availability of mission-critical safety devices, instrumentation, alarms, controls and computers. Robust, StatiVolt UPS Systems are designed and built
More informationYes 20 Charging Wall Cabinet for Tablets
Built with Anthro-DNA Owner's Manual for Yes 20 Charging Wall Cabinet for Tablets Part # YESCABGMPW Components at a Glance 1 2 4 5 8 7 10 Front of Cabinet (closed) 1. Locking front door to User area. 2.
More informationCree Edge Series LED High Output Area/Flood Luminaire featuring Cree TrueWhite Technology
Cree Edge Series LED High Output Area/Flood Luminaire featuring Cree TrueWhite Technology Product Description AA Mount The Cree Edge High Output Area/Flood luminaire is designed to deliver high lumen packages
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and noise allows improved low-level current measurements 3rd party safety certification Applications
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and noise allows improved low-level current measurements 3rd party safety certification Applications
More informationSureTest Model ST-1THD & ST-1THDC Instructions
#61-156 #61-157 #61-158 SureTest Model ST-1THD & ST-1THDC Instructions Introduction The SureTest family of Circuit/distortion analyzers identify problems common to electrical circuits and harmonic distortion
More informationInstallation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B
Instruction Sheet P/N 1047806B Installation of Fillmaster DuraBlue Melters System on WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use
More informationActive UTP Transceiver Hub Installation Guide
Active UTP Transceiver Hub Installation Guide Models Include: HubWayLDH8 HubWayLDH16 - UL Listed eight (8) Channels - UL Listed sixteen (16) Channels Rev. 032108 More than just power. TM Overview: Altronix
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low DC drift and
More informationMichigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE
PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS HCM450 PIZZA CUTTER/MIXER ML-141055 ML-141058 ML-141144 PRIOR ML COVERED IN THIS MANUAL ML-136226 A product of HOBART 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43221 Rev.
More informationAC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet Low
More information1073 & 1084 Channel Amplifier
AMS NEVE 1073 & 1084 Channel Amplifier User Guide 527-341 Issue 3 2004 AMS Neve plc own the copyright of all information and drawings contained in this manual which are not to be copied or reproduced by
More informationAC/DC Current Measurement Systems
AC/DC Current Measurement Systems TCPA300 TCP312 TCP305 TCP303 TCPA400 TCP404XL Datasheet Status Indicators provide Visual Operating Status and Notification of Potential Error Conditions Degauss, Probe
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationYes 20 Charging Wall Cabinet for Tablets
Built with Anthro-DNA Owner's Manual for Yes 20 Charging Wall Cabinet for Tablets Part # YESCABGMPW Components at a Glance 1 2 4 5 8 7 10 3 6 9 Front of Cabinet (closed) 1. Locking front door to User area.
More informationImportant Note 1. Mains Supply (rack units) 4 DC Power Supply Indicators (rack units) Module Module and 1084 Modules 8
User Guide Issue 5 Page i 1073 & 1084 Channel Amplifiers Contents Introduction 1 High Pass Filter (resistor modification) 1 Important Note 1 Installation 2 Dimensions 3 Power Requirements 3 Mains Supply
More informationXMU+ Environmental, Safety and Specifications
XMU+ Environmental, Safety and Specifications Physical Unit Dimensions: Rack Width: Rack Space: Shipping Dimensions: Unit Maximum Weight: Shipping Maximum Weight: Power and Thermal Power Consumption: Heat
More informationADDENDUM NUMBER 1 TO MAINTENANCE MANUAL LBI-4841 Rev. F Refer to ECO#
GENERAL ADDENDUM NUMBER 1 TO MAINTENANCE MANUAL LBI-4841 Rev. F Refer to ECO# 20033252 This addendum updates the AC Outlet Strip NED90106/2 in the manual LBI-4841 Rev. F. CHANGES Replace Figures 1-4, 1-5,
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationSECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION
SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller
More informationSPAC265-8W. AC-DC power supply module. Features. Description. Applications
AC-DC power supply module Datasheet production data Features Open frame switch mode power supply European input voltage range Single output 5 V, 8 W peak power, 4 W continuous operating mode EMC compliance
More informationSmartZone Gateway-Enabled M Series Rack PDU (for Aggregate Power Monitoring)
SmartZone Gateway-Enabled M Series Rack PDU SPECIFICATION SHEET specifications Gateway-Enabled M (Monitored) Series Rack Power Distribution Units (PDUs) safely and efficiently manage and distribute power
More informationNOVA-TS Triple-Single Recloser and Form 5/TS Control Frequently Asked Questions
NOVA-TS Triple-Single Recloser and Form 5/TS Control Frequently Asked Questions How To Use This Publication This document (Bulletin 99068) contains detailed product and application information and provides
More informationAC/DC Current Measurement Systems
AC/DC Current Measurement Systems TCPA300 TCP312 TCP305 TCP303 TCPA400 TCP404XL Data Sheet Lower DC Drift and Noise Allows Improved Low-level Current Measurements Certified for use in U.S., Canada, and
More informationMVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer
MVCT Ability to test both VT and CT Easy to use one-button automated test plans Industry leading test duration using patented simultaneous tap measurements Smallest and lightest unit on the market CT Kneepoints
More informationCurrent Transformers. Technical Data Sheet and Order Form
Current Transformers Technical Data Sheet and Order Form Model CTN2/CTN3/CTN4 (CTNx SERIES) FEATURES: Listed to UL 2808 and CSAC22.2 61010-1 Revenue Grade Accuracy 75A to 600A Full Load Amps (FLA) 50/60Hz
More informationMODEL 421 Over/Under Motor Load Monitor
MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart
More informationFluke 8808A Digital Multimeter Extended Specifications
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Fluke 8808A Digital Multimeter Extended Specifications Making measurements is as simple as pushing a
More informationVaya Cove LP, White & Mono
Vaya Cove LP, White & Mono Vaya Cove LP is a reliable and cost-effective light fixture providing white or mono color light for interior use. Designed for cove and accent lighting applications and with
More informationDistribution Transformer Trainer
8361-00 Distribution Transformer Trainer LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 04/2018 Table of Contents General Description 2 Topic Coverage 2 Features & Benefits 2 List of Manuals
More informationSystem Power Amplifier (SPA)
System Power Amplifier (SPA) Installation Guide SPA-60 Amplifi er Amplifi er EXPLANATION OF SYMBOLS The term WARNING! indicates instructions regarding personal safety. If the instructions are not followed
More informationVaya Cove LP, White & Mono
Vaya Cove LP, White & Mono Vaya Cove LP is a reliable and cost-effective light fixture providing white or mono color light for interior use. Designed for cove and accent lighting applications and with
More informationMajortel DC Power System
DC Power Solutions Majortel DC Power System Full power; Wide AC Range Complete System Design System Capacity Configurations Range from 1740W to 5800W Programmable Alarms Across 4 Sets of Dry-Contacts Battery
More informationAmp Clamp W/True RMS
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61746 600 Amp Clamp W/True RMS Ideal Catalog Number 61746 Manufacturer Ideal Ideal, Clamp Meter, Clamp-Pro, 600 Amp With
More informationPower Processor - Series 700F 10KVA to 150KVA
Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines
More informationElectrical Specifications
Single & Quad output 1 of 5 Total Power: 80-110 W Input Voltage: 85-264 Vac 120-370 Vdc # of Outputs: Single, quad Special Features 7.0 x 4.25 x 1.8 inch package Overvoltage and short circuit protection
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More information12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet
12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet The PSPL8001 12.5 Gb/s Driver Amplifier LABware Module is designed for bench-top lab use. This LABware module can simply be plugged in with
More informationUTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB
PRODUCT CATALOG SUSOL SUPER SOLUTION SELECTION GUIDE UTE00 CATALOG NUMBERING [PRODUCT SELECTION] UTE00 NT FMU 00A 3P LL UL SERIES & FRAME: Susol 00AF PERFORMANCE Rating 80% 00% ka SUFFIX UL : UL 20/ 240Vac
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationCree Edge Series LED High Output Area/Flood Luminaire featuring Cree TrueWhite Technology
Cree Edge Series LED High Output Area/Flood Luminaire featuring Cree TrueWhite Technology Product Description The Cree Edge High Output Area/Flood luminaire is designed to deliver high lumen packages with
More informationInverter MICROMASTER 410
Inverter MICROMASTER 40 /2 Description /4 Circuit diagrams /6 Technical data /7 Selection and ordering data /8 Options /0 Dimension drawings Siemens DA 5.2 2005/2006 / MICROMASTER 40 Description Inverter
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationIDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL series
IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL 61-160 series The Service Information provides the following information Precautions and safety information Specifications Performance test procedure Calibration
More informationNetSure ITM. Contents 1. Site Planning Data 2. One Line Diagram 3. System Outline Drawings 4. Connection Details
A technical manual from the experts in Business-Critical Continuity NetSure ITM Site Planning Data and System Drawings 48V DC UPS Section 6037 (Issue 10, October 21, 2010) Contents 1. Site Planning Data
More informationSpring Return DuraDrive Proportional Actuator
MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional
More informationVideo Data Power. HubWayEXP. UL Listed Sxteen (16) Channel UTP Power Injector. Installation Guide Z1409. More than just power. TM. Rev.
HubWayEXP UL Listed Sxteen (16) Channel UTP Injector Installation Guide Z1409 Rev. 011810 More than just power. TM Overview: Altronix HubWayEXP UTP Injector supplies power combined with pass-through video
More informationPower Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide
Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT Dual Channel Power Amplifier D2 D3 D4 D5 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation Guide
More informationSmart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.
Smart-UPS RT Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004 User Manual 990-1673A, English, 11/2003 General Information General Information
More information1 INTRODUCTION ORDER CODE / INFORMATION
INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O
More informationDatasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors
Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL77/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02,
More information8588A Reference Multimeter
8588A Reference Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of
More informationGeneral Specifications
General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless
More information