1 Directional valves Coils Series CO1 Brochure
2 2 Directional valves Coils Series CO1 Form C, coil kit Coil width 15 mm 3 M8, coil kit Coil width 15 mm 5 form B Coil width 22 mm 7 Form B, industry Coil width 22 mm 9 form A Coil width 30 mm 11 form A Coil width 30 mm 13 with electrical connector Coil width 30 mm ATEX certified 15 Cable with connector Coil width 30 mm ATEX certified 17
3 Directional valves Coils 3 Form C, coil kit Coil width 15 mm Connector standard ISO electrical connections Plug, 3-pin Ambient temperature min./max. -10 C / +50 C Protection class with electrical connector/plug IP65 Duty cycle ED 100 % Materials: Housing Polyamide Technical Remarks Please note that the coils are only compatible with TC series valves that were produced starting in Voltage tolerance Power consumption DC AC 50 AC 60 DC AC 50 AC 60 DC AC 50 Switch-on AC 60 Holding AC 50 AC 60 W VA VA VA VA V 110 V - -10% / +10% -10% / +10% V 230 V - -10% / +10% -10% / +10% V % / +10% V 24 V - -10% / +10% -10% / +10% V % / +10% Weight Note Part No. AC 50 DC AC 60 [kg] 110 V V ) R V V ) R V R V - 24 V ) R V R ) Can only be combined with TC series base valves and TC series valves with alternating (AC).
4 4 Directional valves Coils Form C, coil kit Coil width 15 mm Dimensions
5 Directional valves Coils 5 M8, coil kit Coil width 15 mm Connector standard DIN EN Ambient temperature min./max. -10 C / +50 C Protection class acc. to DIN EN Class III electrically Protection class with electrical connector/plug IP65 Duty cycle ED 100 % LED status display Yellow Materials: Housing Polyamide Technical Remarks Please note that the coils are only compatible with TC series valves that were produced starting in Voltage tolerance Power consumption DC DC DC W 24 V -10% / +10% 2.2 electrical connections Weight Part No. Plug, M8, 4-pin Plug, M8, 3-pin DC [kg] 24 V R R
6 6 Directional valves Coils M8, coil kit Coil width 15 mm Dimensions M8x
7 Directional valves Coils form B Coil width 22 mm 7 Connector standard EN , form B electrical connections Plug Ambient temperature min./max. -- / +50 C Protection class with electrical connector/plug IP65 Duty cycle ED 100 % Materials: Housing Thermoplastic elastomer Voltage tolerance Power consumption DC AC 50 AC 60 DC AC 50 AC 60 DC AC 50 Switch-on AC 60 Holding AC 50 AC 60 W VA VA VA VA 24 V % / +10% -10% / +10% -10% / +10% V 24 V 24 V -10% / +10% -10% / +10% -10% / +10% V 48 V 48 V -10% / +10% -10% / +10% -10% / +10% V % / +10% -10% / +10% -10% / +10% V 110 V 110 V -10% / +10% -10% / +10% -10% / +10% V 220 V 230 V -10% / +10% -10% / +10% -10% / +10% Compatibility index Weight Part No. AC 50 DC AC 60 [kg] - 24 V V 12 V 24 V V 24 V 48 V V V 60 V 110 V V 110 V 230 V
8 8 Directional valves Coils form B Coil width 22 mm Dimensions 22 Ø16 Ø
9 Directional valves Coils 9 Form B, industry Coil width 22 mm Connector standard ISO 6952 electrical connections Plug, Form B, industry Ambient temperature min./max. -- / +50 C Protection class with electrical connector/plug IP65 Duty cycle ED 100 % P581_172 Voltage tolerance Power consumption Switch-on Holding DC AC 50 DC AC 50 DC AC 50 AC 50 W VA VA 12 V V - -10% / +10% V - -10% / +10% V V - -10% / +10% V - -10% / +10% V - -10% / +10% V - -10% / +10% V - -10% / +10% V - -10% / +10% ) Low consumption Weight Note Part No. AC 50 DC [kg] - 12 V V V ) V V V V V V V
10 10 Directional valves Coils Form B, industry Coil width 22 mm Dimensions 30 29,5 2,25 Ø15,5 29 Ø8 17 Ø16,
11 Directional valves Coils 11 form A Coil width 30 mm Connector standard EN , form A electrical connections Plug Ambient temperature min./max. -- / +50 C Protection class with electrical connector/plug IP65 Duty cycle ED 100 % Materials: Housing Thermoplastic elastomer Voltage tolerance Power consumption DC AC 50 AC 60 DC AC 50 AC 60 DC AC 50 Switch-on AC 60 Holding AC 50 AC 60 W VA VA VA VA 12 V % / +10% V % / +10% V 24 V - -20% / +10% -10% / +20% V % / +10% V 110 V - -20% / +10% -10% / +20% V 240 V - -20% / +10% -10% / +20% V % / +10% V 24 V - -20% / +10% -10% / +20% V 110 V - -20% / +10% -10% / +20% V 230 V - -20% / +10% -10% / +20% V 24 V 24 V -10% / +10% -10% / +10% -10% / +10% V % / +10% -10% / +10% -10% / +10% V 110 V - -10% / +10% -10% / +10% V 220 V 230 V -10% / +10% -10% / +10% -10% / +10% Compatibility index Weight Part No. AC 50 DC AC 60 [kg] - 12 V V V - 24 V V V V V V V V - 24 V V V V V V 12 V 24 V V V V V 110 V 230 V
12 12 Directional valves Coils form A Coil width 30 mm Dimensions 30 Ø16 Ø
13 Directional valves Coils 13 form A Coil width 30 mm Connector standard EN , form A electrical connections Plug Ambient temperature min./max. -20 C / +50 C Protection class with electrical connector/plug IP65 Duty cycle ED 100 % Materials: Housing Thermoplastic elastomer Voltage tolerance Power consumption DC AC 50 AC 60 DC AC 50 AC 60 DC AC 50 Switch-on AC 60 Holding AC 50 AC 60 W VA VA VA VA 12 V % / +10% V % / +10% V % / +10% V % / +10% V % / +10% V 24 V - -10% / +10% -10% / +10% V 110 V - -10% / +10% -10% / +10% V 230 V - -10% / +10% -10% / +10% Part No. AC 50 DC AC V V V V V V - 24 V V V V V
14 14 Directional valves Coils form A Coil width 30 mm Dimensions 30 Ø26 Ø13, V DC 10W X-XXX-X Max. 37,
15 Directional valves Coils 15 with electrical connector Coil width 30 mm ATEX certified ATEX II 3G Ex nac IIB T4 II 3D Ex tc IIIB T125 C IP65X Ambient temperature min./max. -10 C / +50 C Protection class IP65 Duty cycle ED 100 % Compatibility index CI Voltage tolerance Power consumption Switchon DC AC 50 AC 60 DC AC 50 AC 60 DC AC 50 Holding AC 50 W VA VA - 24 V 24 V - -20% / +10% -10% / +20% V 110 V - -20% / +10% -10% / +20% V 230 V - -20% / +10% -10% / +20% V % / +10% Weight Part No. AC 50 DC AC 60 [kg] 24 V - 24 V R V V R V V R V R
16 16 Directional valves Coils with electrical connector Coil width 30 mm ATEX certified Dimensions 71,2 56,5 34, ,5 27, ,4 max. 38,5 Ø 19 Ø 5,5-8 35,
17 Directional valves Coils 17 Cable with connector Coil width 30 mm ATEX certified ATEX II 2G Ex mb IIC T4 Gb II 2D Ex mb tb IIIC T 130 C Db IP65 Ambient temperature min./max. -20 C / +50 C Protection class IP65 Duty cycle ED 100 % Compatibility index CI Voltage tolerance Power consumption Switch-on Holding DC AC 50 AC 60 DC AC 50 DC AC 50 AC 50 W VA VA V 230 V - -10% / +10% V 110 V - -10% / +10% V 24 V - -10% / +10% V % / +10% Cable length L Weight Part No. AC 50 DC AC 60 [m] [kg] 230 V V V V V V V V V - 24 V V - 24 V V V
18 18 Directional valves Coils Cable with connector Coil width 30 mm ATEX certified Dimensions 67 14,8 Ø 7 1) 18 29,5 L 7 50 Ø 22 31,25 1,25 Ø 9,01 29,7 L = cable length 1) Cable ID band with serial number
19 AVENTICS GmbH Ulmer Straße Laatzen, GERMANY Phone Fax info@aventics.com Find more contact information at Only use the AVENTICS products shown in industrial applications. Read the product documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When integrating the product into applications, note the system manufacturer s specifications for safe use of the product. The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are subject to a natural process of wear and aging An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. AVENTICS S.à r.l. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS S.à r.l.. It may not be reproduced or given to third parties without its consent. PDF online
Directional valves Electrically operated Series 563, 565, 567. Brochure
Directional valves Electrically operated Brochure 2 Directional valves Electrically operated 3/2-directional valve, Series 563 Qn = 1350 l/min plate connection Electr. connection: Plug, Form B, industry
More informationSensor technologies Proximity sensors Series ST9. Brochure
Sensor technologies Proximity sensors Series ST9 Brochure 2 Sensor technologies Proximity sensors Series ST9 9 mm groove with cable without wire end ferrule, tin-plated, 2-pin, without wire end ferrule,
More informationSensor technologies Distance measuring sensors Series SM6-AL. Brochure
Sensor technologies Distance measuring sensors Series SM6-L Brochure 2 Sensor technologies Distance measuring sensors Series SM6-L with cable Plug, M8x1, 4-pin with distance measuring sensor, measurement
More informationRotary actuators Rotary wing drives Series RAK. Brochure
rochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
More informationSensor technologies Distance measuring sensors Series SM6-AL. Brochure
Sensor technologies Distance measuring sensors Series SM6-L Brochure 2 Sensor technologies Distance measuring sensors Series SM6-L with cable Plug, M8x1, 4-pin with distance measuring sensor, measurement
More informationPlug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8
Plug-in amplifier RE 30264/07.12 Replaces: 03.10 1/8 Type VT-SSPA1 Component series 2X Table of contents Contents Page Features 1 Ordering code, accessories 2 Function 3 Connections and adjustment 3 Block
More informationSensor technologies Distance measuring sensors Series SM6. Brochure. C/ Centauro, 13 Área Empresarial Las Cubiertas Griñón (Madrid)
Sensor technologies Distance measuring sensors Series SM6 Brochure C/ Centauro, Área Empresarial Las Cubiertas 897-Griñón (Madrid) T. 00 9 6 667 info@diversiatec.com www.diversiatec.com Sensor technologies
More informationAnalogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6
Analogue amplifier RE 29980/09.05 Replaces: 02.03 1/6 Type VT-SR2 Series 1X H5658 Table of contents Contents Page eatures 1 Ordering code 2 unctional description 2 Technical data 3 Block circuit diagram
More informationValve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features
Valve amplifier for high-response valves Type VT-VRRA1-527-2X/V0/2STV, VT-VRRA1-527-2X/V0/PO-IS RE 30045 Edition: 2013-04 Replaces: 02.12 Component series 2X Analog, euro-card format Suitable for controlling
More informationValve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:
Valve amplifier for proportional valves Type VT-SSPA- (5, 50, 00, 50) RE 306 Edition: 05-03 Replaces: 04-07 Component series X Analog, connector design Suitable for controlling solenoid-actuated pressure
More informationElectric amplifier for proportional cartridge throttle valves
Electric amplifier for proportional cartridge throttle valves RE 30053/09.05 1/8 Type VT-VRPA1-527-2X/V0/RTS-2/2V Unit series 2X List of contents Contents Page Features 1 Ordering data 2 Preferred types
More informationElectric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6
Electric amplifiers RE 30048/08.12 Replaces: 03.12 1/6 Type VT-VRPA2-5...-1X/V0/RTP Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram
More informationElectric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6
Electric amplifiers RE 30052/08.05 Replaces: 05.04 1/6 Type VT-VRPA1 Unit series 1X List of contents Contents Page Features 1 Ordering data 2 Preferred types 2 Front panel 3 Circuit diagram with pin assignment
More informationElectric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6
Electric amplifiers RE 30052/02.12 Replaces: 01.09 1/6 Type VT-VRPA1-5...-1X/V0/... Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram
More informationAVENTICS: AGILE, FOCUSED, AND WITH PASSION FOR TOMORROW S MARKETS
AVENTICS: AGILE, FOCUSED, AND WITH PASSION FOR TOMORROW S MARKETS troduction AVENTICS Our ambition is to become known as the smart pneumatic engineering company that is easy to do business with. Paul Cleaver,
More information100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features
C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,
More informationBooster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6
Booster amplifier RE 30260/04.12 Replaces: 08.11 1/6 Type VT-MSFA1 Component series 1X H7924 Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block diagram / pinout 3
More information4/3 proportional directional valve direct operated, with integrated electronics
4/ proptional directional valve direct operated, with integrated electronics RE 2964/. Replaces: 2.2 /6 Type 4WREEM Sizes 6 and Component series 2X Maximum operating pressure 5 bar Maximum flow: 9 l/min
More informationElectric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6
Electric amplifiers RE 30054/03.12 Replaces: 01.09 1/6 Type VT-VRPA1-5...-1X/...-RTP Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram
More informationM224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #
Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db
More informationValve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents
Valve amplifier for proportional directional valves and proportional pressure valves Type VT-VSPA2-1 RE 30110 Edition: 2013-04 Replaces: 05.12 Component series 2X Analog, euro-card format Suitable for
More informationIncremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution
Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm
More informationAnalog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Analog Amplifier RA RE 95 230/03.06 1/12 replaces: RE 95 022 RE 95 023 RE 29 874 RE 29 875 Technical Data
More informationValve amplifier for proportional valves with electrical position feedback
Valve amplifier for proportional valves with electrical position feedback Type VT-MRPA1-... RE 30221 Edition: 2015-02 Replaces: 2013-08 Component series 1X Analog, modular design Intended for controlling
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationDirectional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)
Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29035 Edition: 2017-04 Replaces: 2015-02 Size 6 Component series 2X Maximum
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationValve amplifier for proportional pressure valves
Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More information11 Product group. Inductive transducers in cylindrical metal housings A WA F A WA X A WD X A WU X
Inductive s in cylindrical metal housings 11 Product group A WA F A WA X A WD X A WU X Application The inductive is a linear displacement measuring system. It can either be fl ange-mounted at a solenoid
More informationValve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05
Valve amplifier for proportional directional valves Type VT-VRPA RE 0119 Edition: 01-0 Replaces: 07.05 Component series 1X Analog, Euro-card format Suitable for controlling / proportional directional valves
More informationAnalog amplifier RA. RE Edition: Replaces:
Analog amplifier RA RE 950 Edition: 08.05 Replaces: 0.006 For control of simple functions of electrohydraulic components Two power outputs (PWM) and one switching output Each output has a separately adjustable
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationAnalog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X
Analog amplifier RE 29926/10.06 Replaces: 0.03 /8 Type VT 3006 Component Series 3X H4240_d Table of contents Contents Page eatures 1 Ordering code 2 unctional Description 2 and 3 Block circuit / pin allocation
More informationIncremental encoders Blind hollow shaft or cone shaft pulses per revolution
Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80
More informationElectric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Electric amplifiers RA 30052/05.04 1/6 Model VT-VRPA1 Series 1X Table of contents Contents Page Features
More informationAnalogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting
Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationTension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.
Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 tecsis data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology
More informationGEMÜ 1242 Electrical position indicator
Electrical position indicator Features Fieldbus connection AS-Interface and DeviceNet (optional) Communication and programming interface IO-Link Adjustable switch point tolerances Speed -AP function for
More informationProduct Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications
Product Information RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications September 2013 RCN 2000 series Absolute angle encoders for safety-related applications Safe absolute
More informationTension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.
Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 WIKA data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology
More informationIBV 100/EXE 100 Interpolation and Digitizing Electronics
Linear Encoders Angle Encoders IBV 1/EXE 1 Interpolation and Digitizing Electronics Rotary Encoders 3-D Touch Probes Position Display Units Numerical Controls HEIDENHAIN linear, rotary and angle encoders
More informationRelative and absolute pressure transmitter type 528
Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters
More information2/2 way Coaxial Valve CX03M to CX05M direct acting
2/2 way Coaxial Valve CX03M to CX05M direct acting Model code (also example order) CX03M 2/2 D C 2 10 040 014 24V Switching function Designation CX03M = CX03M series CX04M = CX04M series CX05M = CX05M
More informationFloat switch For industrial applications, plastic version Model RLS-2000
Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring
More informationBEST CONNECTIONS IN EVERY ENVIRONMENT
BEST CONNECTIONS IN EVERY ENVIRONMENT VG & MIL SPACE & AEROSPACE ATEX & IECEX SUBSEA FIBER OPTIC ACCESSORIES CABLE HARNESSES CUSTOMIZED PRODUCTS SERVICE DIN EN 9120 DIN ISO 9001 VG96927 ATEX IECEX VG &
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationp/q closed-loop control amplifier
p/q closed-loop control amplifier RE 30134 Edition: 2017-05 Replaces: 06.12 1/12 Type VT-VACA-500-2X/V0/... Component series 2X Table of contents Contents age Features 1 Ordering code, accessories 2 Front
More informationTemposonics. Magnetostrictive Linear Position Sensors. ET Start/Stop Data Sheet. High operating temperature Compact sensor housing ATEX certified
Temposonics Magnetostrictive Linear Position Sensors ET Start/Stop High operating temperature Compact sensor housing ATEX certified The Measurable Difference Temposonics ET Start/Stop MEASURING TECHNOLOGY
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.
More informationMeasuring current transformers of the W AB(P) series
Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017 Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB
More informationValve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:
Valve amplifier for proportional valves Type VT-MSPA2-1 RE 30228 Edition: 2014-01 Replaces: 2011-04 Component series 1X Suitable for controlling direct operated proportional directional valves without
More informationNivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50
Technical Information Nivotester 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Area of application The Nivotester is suitable as a 1-channel switch amplifier for the Soliwave
More informationSOLENOIDS, COILS & ACCESSORIES Product Index
SOLENOIDS, COILS & ACCESSORIES Product Index Description Series Page Coil identification Catalogue numbers of replacement coils SOLENOID OPERATORS Solenoid s, description and dimensions V1100-2/3 V1100-4..6
More informationHigh-response valve with integrated digital axis controller (IAC-R) and field bus interface
High-response valve with integrated digital axis controller (IAC-R) and field bus interface RE 99/09.0 Replaces: 06.05 / Type 4WRPNH.../4C... Type 4WRPNH.../4P... Size 6 and 0 Component series X Maximum
More informationTechnical Datasheet FOP 60 and OPTV Fibreoptical Amplifier and Lightpulse Receiver
www.kem-kueppers.com info@kem-kueppers.com Technical Datasheet FOP 60 and OPTV Fibreoptical Amplifier and Lightpulse Receiver Certified according to DIN EN ISO 9001 2 FOP 60 and OPTV Fibre-Optic Amplifier
More informationExplosion proof rotary actuator - On/Off or programmable regulating actuator
Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can
More informationProduct Information. ECN 1313 ECN 1325 ERN 1387 Rotary Encoders with Plane-Surface Coupling for Elevator Servo Drive Control
Product Information ECN 1313 ECN 1325 ERN 1387 Rotary Encoders with Plane-Surface Coupling for Elevator Servo Drive Control July 2017 ECN/ERN 1300 series Rotary encoders with integral bearings for elevator
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationCoil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil
s W COILS Type of protection IP 65 Ambient -30 C 60 C F 0.141 kg 42 12 Ø13.25 30 38.6 ISO 4400 (DIN 43650) 17 21.5 20.5 STANDARD irschmann ISO 4400 DIN43650 L 12 VDC 135 C W 7.7 Ω M14000001 M 24 VDC 135
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationLoad pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1
Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 WIKA data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant
More informationProduct Information. ECN 413 ECN 425 ERN 487 Rotary Encoders for Elevator Drive Control (IP64 Degree of Protection)
Product Information ECN 413 ECN 425 ERN 487 Rotary Encoders for Elevator Drive Control (IP64 Degree of Protection) June 2017 ECN/ERN 400 series Rotary encoders with integral bearings for elevator technology
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationProduct Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface
Product Information EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface 11/2017 EQN 1337 F Rotary encoders for absolute position values Installation diameter 65 mm
More informationSINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex
for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate
More informationService case with test unit for servo and proportional valves with integral electronics (OBE)
Service case with test unit for servo and proportional valves with integral electronics (OBE) RE 29685/03.11 Replaces: 07.10 1/12 Type VT-VETSY-1 Series 1X H/A/D 5967/98 Table of contents Contents Page
More information4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.
4/ proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF RE 9048 Edition: 0-0 Replaces:. Sizes 6 and 0 Component series X Maximum operating pressure
More informationLoad pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1
Force Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1 tecsis data sheet FO 51.43 Applications Crane systems, hoists, offshore Industrial weighing technology Machine
More informationü ( Explosion Protection
Explosion Protection ü www.nassmagnet.com ( +49 11 6746-0 Explosion Protection SOLENOID COILS FOR USE IN POTENTIALLY EXPLOSIVE ENVIRONMENTS nass magnet offers components of the series System 8 and System
More informationLocal control stations for Zone 1 and Zone 21. Features. Description
Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning
More informationServomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16
MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......
More informationElectronically controlled proportional pressure regulating valves
Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationTZIF 4. Current-to-Pulse Converter 10/ EN
TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote
More information... for hydraulic and general applications in hazardous areas
ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified
More informationHARTING Han-Power T Solutions
HARTING Han-Power T Solutions Fields of Application HARTING industrial connectors are suitable in a wide variety of electronic and electrical applications. Power utilities Robotics Machine tool controls
More informationSystem protection by Vibration monitoring
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans System protection by Vibration monitoring for fans 2 Ventilatoren Vibration monitoring for fans
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationSolexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:
OVERVIEW The Solexy RX series explosion proof and intrinsically safe antenna coupler is an integrated protection device that facilitates non-ex certified radio antenna installation in hazardous areas.
More informationMultiturn absolute encoder
0102 Model Number SYNCHRON SERIELLES INTERFACE Features Up to 30 Bit multiturn ATEX approval IECEx approval Flameproof enclosure Removable connection cap Galvanically isolated RS 22 interface Description
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationRelative and absolute pressure transmitter type 528
Relative and absolute pressure transmitter type 528 Pressure range -1... 0 60 bar Váš dodavatel: JSP, s.r.o. Raisova 547 506 01 Jičín JSP Měření a regulace www.jsp.cz tel.: +420 493 760 811 fax: +420 493
More informationLoad pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1
Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 tecsis data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant
More informationKDS. All Metal Variable Area Flowmeter. for Liquids and Gases
All Metal Variable Area Flowmeter for Liquids and Gases measuring monitoring analysing : 0.1-1... 20-200 water 3-30 Nm3/h... 600-6000 Accuracy: ±3 % of full p max : 420 bar; t max : 130 C Connection: ¼"
More informationOperating Instructions
Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationEdition March 2011 With publication of this catalogue all former printed general catalogues about RECHNER sensors are invalid.
SHORTFORM CATALOGUE Registration No.: 1327-01 Testing laboratory accredited according to DIN EN 001 Reg.-No. DAT-P-08/9-00 For all transactions, the newest version of the General Conditions of Sale and
More informationMoeller Electric Corporation
EMR4-I Current Monitoring Relays 02/0053 EMR4-I1-2-A EMR4-I15-2-A EMR4-I15-2-B Mechanical lifespan operations x10 6 30 30 30 24-h cycle, 55 C, 93 % relative humidty, 96 h Ambient temperature min./max.
More informationProportional rotary solenoid G DR
Proportional rotary solenoid 6 Product group G DR Function Proportional Rotary Solenoid Linear torque vs. rotation angle characteristic Constant torque in the operating range Proportional behaviour between
More informationSignal Beacon - LED Series 6162
www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure
More informationElectric amplifier for flow control with proportional
Electric amplifier for flo control ith proportional valves RE 29955/07.14 Replaces: 09.11 1/8 Type VT 5035 Component series 1X H5581 Table of contents Content Page eatures 1 Ordering code 2 unctional description