AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15
|
|
- Josephine Logan
- 6 years ago
- Views:
Transcription
1 AUTOMOTIVE CURRENT TRANSDUCER Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications. Its contains galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). The DHAB family gives you a choice of having different current measuring ranges in the same housing (from ± 20 up to ± 600 A). Features Open Loop transducer using the Hall effect sensor Low voltage application Unipolar + 5 V DC power supply Primary current measuring range up to ± 60 A for range 1 and ± 600 A for range 2 Maximum RMS primary admissible limited by the busbar, the magnetic core or the ASIC temperature T < C Operating temperature range: - 40 C < T < C Output voltage: fully ratiometric (in sensitivity and offset) 2 measuring ranges to have a better accuracy. Principle of DHAB Family The open loop transducers uses a Hall effect integrated circuit. The magnetic flux density B, contributing to the rise of the Hall voltage, is generated by the primary current I P to be measured. The current to be measured I P is supplied by a current source i.e. battery or generator (Fig. 1). Within the linear region of the hysteresis cycle, B is proportional to: B (I P ) = constant (a) x I P The Hall voltage is thus expressed by: V H = (R H /d) x I x constant (a) x I P Except for I P, all terms of this equation are constant. Therefore: V H = constant (b) x I P The measurement signal V H amplified to supply the user output voltage or current. Advantages Good accuracy for high and low current range +V c Good linearity Low thermal offset drift Low thermal sensitivity drift Hermetic package. I P -V c 0V V out Automotive applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles. Principle of HAH1DR Famil Primary current I P Fig. 1: Principle of the open loop transducer Isolated output voltage Page 1/6
2 Dimensions (in mm.) Bill of materials System architecture (example) Plastic case >PA66-GF25< Magnetic core : FeNi alloy : FeSi alloy Pins Brass tin plated Mass 77 g IP Primary current LEM - DHAB sensor + 5V 100 nf 10 nf VC Typical application Schematic interface CLOAD 47 nf RLOAD R + 5V C R 10 nf CLOAD RLOAD C R L > 10 kw optional resistor for signal line diagnosis C L < 100 nf EMC protection RC Low pass filter EMC protection (optional) Page 2/6
3 Absolute maximum ratings Supply voltage Operating characteristics V C Over voltage V 14 1 min Reverse voltage T A Output voltage (Analog) V 8.5 V Output over voltage (Analog) OUT V 14 1 T A Continuous output current I OUT ma Output short-circuit duration T c min 2 Ambient storage temperature T S C Note: 1) The output voltage V OUT is fully ratiometric (concerning V O, sensitivity and clamping) and is dependent on the supply voltage V C relative to the following formula: VC 1 5 IP = VOUT with G in (V / A) 2 G VC 8.5 Supply voltage V C V Output current (Analog) I OUT ma Current consumption I C ma Power up inrush current V C < 3.5 V Load resistance R L ΚΩ 10 Capacitive loading C L nf Ambient operating temperature T A C High accuracy Reduced accuracy Primary current I P channel 1 A Calibration current I CAL -60 T A Offset voltage 1) V O V V C Sensitivity 1) G mv/a V C Resolution mv V C Output clamping voltage min 1) V C V SZ V Output clamping voltage max 1) V C Output internal resistance R OUT Ω 1 10 Frequency bandwidth BW KHz -3 db Power up time ms 110 Setting time after over load ms 25 Primary current I P channel 2 A Calibration current I CAL -500 T A Offset voltage V O V V C Sensitivity G mv/a V C Resolution mv V C Output clamping voltage min V C V SZ V Output clamping voltage max V C Output internal resistance R OUT Ω 1 10 Frequency bandwidth BW KHz -3 db Power up time ms 110 Setting time after over load ms 25 Page 3/6
4 ACCURACY Electrical offset current I OE channel 1 ma ± T A Magnetic offset current I OM channel 1 ma ± T A T A Global offset current I O channel 1 ma C < T < 65 C C < T < 125 C ± T A Sensitivity error ε G % ± - 10 C < T < 65 C ± - 40 C < T < 125 C Linearity error ε L % ± 0.5 off full range Temperature Global Offset Error ± 0.69 ± 0.57 ± 0.45 ± 0.30 ± 0.54 ± 0.90 Global ± 1.58 ± 1.28 ± 0.98 ± 0.60 ± 1.20 ± 2.10 Global ± 2.27 ± 1.85 ± 1.43 ± 0.90 ± 1.74 ± 3.00 ± 3.50 DHAB S15 : Global Absolute Error ± 3.00 Global absolute error (A) ± 2.50 ± 2.00 ± 1.50 ± 1.00 ± 0.50 ± Temperature ( C) Global Offset Error Global Global Page 4/6
5 ACCURACY Electrical offset current I OE channel 2 A ± T A Magnetic offset current I OM channel 2 A ± T A - 6 T A Global offset current I O channel 2 A C < T < 65 C C < T < 125 C ± T A Sensitivity error ε G % ± - 10 C < T < 65 C ± - 40 C < T < 125 C Linearity error ε L % ± 0.5 off full range Temperature Global Offset Error ± 6.65 ± 6.45 ± 6.25 ± 6.00 ± 6.40 ± 7.00 Global ± ± ± 9.95 ± 8.00 ± ± Global ± ± ± ± ± ± ± DHAB S15 : Global Absolute Error ± Global absolute error (A) ± ± ± ± 5.00 ± Temperature ( C) Global Offset Error Global Global Page 5/6
6 PERFORMANCES PARAMETERS DEFINITIONS Output noise voltage: The output voltage noise is the result of the noise floor of the Hall elements and the linear I C amplifier gain. Magnetic offset: The magnetic offset is the consequence of an over-current on the primary side. It s defined after an excursion of I P max. Linearity: The maximum positive or negative discrepancy with a reference straight line V OUT = f (I P ). Unit: linearity (%) expressed with full scale of I P max. Linearity is measured on cycle + I P, O, - I P, O, + I P without magnetic offset (average values used) Sensitivity: The Transducer s sensitivity G is the slope of the straight line V out = f (I P ), it must establish the relation: V out (I P ) = V C /5 (G x I P + 2.5) (*) (*) For all symetrics transducers. Offset with temperature: The error of the offset in the operating temperature is the variation of the offset in the temperature considered with the initial offset at 25 C. The offset variation I OT is a maximum variation the offset in the temperature range: I OT = I OE max - I OE min The Offset drift TCI OEAV is the I OT value divided by the temperature range. Reference straight line V OUT Non linearity example Max linearity error Linearity variation in I N % I P Sensitivity with temperature: The error of the sensitivity in the operating temperature is the relative variation of sensitivity with the temperature considered with the initial offset at 25 C. The sensitivity variation G T is the maximum variation (in ppm or %) of the sensitivity in the temperature range: G T = (Sensitivity max - Sensitivity min) / Sensitivity at 25 C. The sensitivity drift TCG AV is the G T value divided by the temperature range. Response time (delay time) t r : The time between the primary current signal and the output signal reach at 90 % of its final value Offset I P = 0 A: Is the output voltage when the primary current is null. The ideal value of V O is V C /2 at V C. So, the difference of V O -V C /2 is called the total offset voltage error. This offset error can be attributed to the electrical offset (due to the resolution of the ASIC quiescent voltage trimming), the magnetic offset, the thermal drift and the thermal hysteresis. I [A] I T Environmental test specifications Name Standard I P 90 % I S Thermal shocks GM &5.5.5 (IEC Part 2-14) T - 40 C to 125 C / 300 cycles not connected. Criteria: ε G < 3 25 C t r Power temperature GM &5.5.6 (IEC Part 2-14 Nb T C/595 cycles, supply voltage Criteria: ε G < 3 25 C Temperature humidity cycle test GM & (IEC ) T C/10 cycles, supply voltage Criteria: ε G < 3 25 C Mechanical tests t [µs] Typical: Theorical value or usual accuracy recorded during the production. Vibration test Drop test GM &6.6.2 (IEC ) GM &6.10 (IEC ) EMC Test Acceleration 30m/s2, 25 C, frequency 20 to 1000 Hz/8h each axis Drop 1m, 2 falls/part, 1 part/axis, 3 axes, criteria: relative sensitivity error 3% Rms voltage for AC isolation test GM & (IEC ) Bulk current injection immunity ISO Criteria B Electrostatic discharge immunity test 2 KV, Criteria B Page 6/6
AUTOMOTIVE CURRENT SENSOR DHAB S/18. Datasheet
AUTOMOTIVE CURRENT SENSOR DHAB S/18 Datasheet 070720/1 Page 1/6 Introduction The DHAB family is best suited for DC, AC or pulse current measurement in high power and low voltage automotive applications.
More informationAUTOMOTIVE CURRENT SENSOR DHAB S/25. Datasheet
AUTOMOTIVE CURRENT SENSOR DHAB S/25 Datasheet Page 1/6 Introduction The DHAB family is best suited for DC, AC or pulse current measurement in high power and low voltage automotive applications. It s contains
More informationAUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S
AUTOMOTIVE CURRENT TRANSDUCER Introduction The HAH1DR family is for the electronic measurement of DC, AC or pulsed currents in high power automotive applications with galvanic isolation between the primary
More informationAUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02
AUTOMOTIVE CURRENT TRANSDUCER Introduction The HAH3DR family, a tri-phase tranducer is for the electronic measurement of DC, AC or pulsed s in high power automotive applications with galvanic isolation
More informationAUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00
AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00 Introduction The HAH3DR family, a tri-phase tranducer is for the electronic measurement of DC, AC or pulsed s in high power automotive applications with galvanic
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124 Picture of product with pencil Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low
More informationAUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS
AUTOMOTIVE CURRENT TRANSDUCER HCF-SN CLIPS Introduction The HCF CLIPS Family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications with galvanic
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S
AUTOMOTIE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAHDR 2-S Introduction The HAHDR family is for the electronic measurement of DC, AC or pulsed currents in high power automotive applications with galvanic
More informationAUTOMOTIVE CURRENT TRANSDUCER HC6F600-S
AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S 18198102215 Page 1/5 Introduction Principle of HC6F Family The HC6F Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and
More informationAUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S
AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S 18198151434 Page 1/ 5 HC6H1000-S Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in
More informationAUTOMOTIVE CURRENT TRANSDUCER HC6F700-S
AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S 18198102215 Page 1/5 Introduction Principle of HC6F Family The HC6F Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and
More informationAUTOMOTIVE CURRENT SENSOR HC6H300-S
AUTOMOTIVE CURRENT SENSOR HC6H300-S Page 1/ 5 Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157 Introduction The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications.
More informationAUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet
AUTOMOTIVE CURRENT SENSOR HC6H500-S Datasheet Page 1/ 5 Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and low
More informationHC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet
AUTOMOTIVE CURRENT TRANSDUCER Datasheet 071113/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/ 6 www.lem.com Introduction
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH1DRW family is for the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive applications with
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH3DR-S03 family is a tri-phase transducer for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications.
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH3DR-S07 family is a tri-phase transducer for DC, AC, or pulsed currents measurement in automotive applications. It offers a galvanic
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01
AUTOMOTIE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HSW S01 Introduction The HSW family is best suited for DC and AC currents measurement in high power and high voltage automotive applications. It features
More informationAUTOMOTIVE CURRENT TRANSDUCERS OPEN LOOP TECHNOLOGY
AUTOMOTIVE CURRENT TRANSDUCERS OPEN LOOP TECHNOLOGY HSNBV 100-(*)X00; HSNBV 200-X00; HSNBV 300-X00; HSNBV 400-X00; HSNBV 500-X00; HSNBV 600-X00; HSNBV 700-X00; HSNBV 800-X00; HSNBV 900-X00; * Introduction
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S0C
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S0C Introduction The HAH3DR-S0C family is a dual-phase transducer for DC, AC, or pulsed currents measurement in high power and low voltage
More informationAUTOMOTIVE CURRENT TRANSDUCER HAB 60-S/SP5
AUOMOIVE CURREN RANSDUCER HAB 60-S/SP5 Introduction he HAB Family is best suited for DC, AC or pulsed currents measurement in high power and low voltage automotive applications. It s contains galvanic
More informationCurrent Sensor: ACS750xCA-100
5 Pin 1: V CC Pin 2: Gnd Pin 3: Output 4 1 2 3 Terminal 4: I p+ Terminal 5: I p- ABSOLUTE MAXIMUM RATINGS Operating Temperature S... 2 to +85ºC E... 4 to +85ºC Supply Voltage, Vcc...16 V Output Voltage...16
More informationHigh Performance Current Transducer IT 200-S ULTRASTAB = A. ε L
High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM
More informationAUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX
AUTOMOTIVE CURRENT TRANSDUCER FLUXGATE TECHNOLOGY CAB 300-C/SP3-XXX Introduction The CAB family is for battery monitoring applications where high accuracy and very low offset are required. Features Transducer
More informationCurrent Sensor: ACS752SCA-050
5 4 The Allegro ACS75x family of current sensors provides economical and precise solutions for current sensing in industrial, automotive, commercial, and communications systems. The device package allows
More informationCurrent Sensor: ACS750xCA-050
5 4 The Allegro ACS75x family of current sensors provides economical and precise solutions for current sensing in industrial, automotive, commercial, and communications systems. The device package allows
More informationCurrent Sensor: ACS755SCB-200
Pin 1: VCC Pin 2: GND Pin 3: VOUT Terminal 4: IP+ Terminal 5: IP AB SO LUTE MAX I MUM RAT INGS Supply Voltage, V CC...16 V Reverse Supply Voltage, V RCC... 16 V Output Voltage, V OUT...16 V Reverse Output
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 700-S ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationCurrent transducer FHS 40-P/SP600
Current transducer I PM = 0-100 A Minisens transducer The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer ITN 1000-S ULTRASTAB I PM = 1000 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 700-SB ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features ± 10 V voltage output
More informationCurrent Sensor: ACS754xCB-100
Pin 1: VCC Pin 2: GND Pin 3: VOUT 5 4 1 2 3 Package CB-PFF 5 1 2 3 Package CB-PSF 1 2 3 5 4 Package CB-PSS 4 Terminal 4: IP+ Terminal 5: IP AB SO LUTE MAX I MUM RAT INGS Supply Voltage, V CC...16 V Output
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.
Current Transducer CASR series I PN = 6, 5, 25, 5 A Ref: CASR 6-NP, CASR 5-NP, CASR 25-NP, CASR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary
More informationHigh Performance Current Transducer ITL 900-T = A
High Performance Current Transducer ITL 900-T For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I PM = 0... 900 A Electrical
More informationHO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31
Current Transducer HO-S/SP3 series Ref: I PN = 5,, 15, 2, 25 A HO 5-S/SP3, HO -S/SP3, HO 15-S/SP3, HO 2-S/SP3, HO 25-S/SP3 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation
More informationCurrent Sensor: ACS754SCB-200
Pin 1: VCC Pin 2: GND Pin 3: VOUT Terminal 4: IP+ Terminal 5: IP AB SO LUTE MAX I MUM RAT INGS Supply Voltage, V CC...16 V Reverse Supply Voltage, V RCC... 16 V Output Voltage, V OUT...16 V Reverse Output
More informationLimited Availability Product
Limited Availability Product This device is in production, but is limited to existing customers. Contact factory for additional information. Date of status change: November 2, 2009 Recommended Substitutions:
More informationRef: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33
Current Transducer HO-S/SP33 series I PN = 50, 100, 150, 200, 250 A Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33 For the electronic measurement of current: DC, AC, pulsed...,
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationRef: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3
Current Transducer HLSR-P/SP3 series N = 10... 50 A Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation
More informationLast Time Buy. Deadline for receipt of LAST TIME BUY orders: May 1, 2008.
Last Time Buy These parts are in production but have been determined to be LAST TIME BUY. This classification indicates that the product is obsolete and notice has been given. Sale of this device is currently
More informationTypical Application C BYP C F 3 R F
Features and Benefits Monolithic Hall IC for high reliability Single +5 V supply 3 kv RMS isolation voltage between terminals 4/5 and pins 1/2/3 for up to 1 minute 35 khz bandwidth Automotive temperature
More informationDiscontinued Product
Discontinued Product These parts are no longer in production The device should not be purchased for new design applications. Samples are no longer available. Date of status change: May 4, 2009 Recommended
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer CKSR series N = 6, 5, 25, 5 A Ref: CKSR 6-NP, CKSR 5-NP, CKSR 25-NP, CKSR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary
More informationRef: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM
Current Transducer HLSR-SM series N = 1... 5 A Ref: HLSR 1-SM, HLSR 16-SM, HLSR 2-SM, HLSR 32-SM, HLSR 4-SM, HLSR 5-SM For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationI PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S
Current Transducer HO-S series I PN = 50, 100, 150, 200, 240, 250 A Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S For the electronic measurement of current: DC, AC, pulsed..., with galvanic
More informationVoltage transducer DVL 50
Voltage transducer DVL 5 V PN = 5 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated measurement
More informationRef: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33
Current Transducer HLSR-SM/SP33 series I PN = 10... 50 A Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33 For the electronic measurement of current: DC, AC, pulsed...,
More informationTypical Application VCC IP+ ACS755 GND C F 3 R F
Features and Benefits Monolithic Hall IC for high reliability Single +5 V supply 3 kv RMS isolation voltage between terminals 4/5 and pins 1/2/3 for up to 1 minute 35 khz bandwidth Automotive temperature
More informationFor the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.
Voltage transducer DVL 15 V PN = 15 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer CAS 25-NP/SP2 N = 25 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationCurrent Transducer CTSR 1-P = 1A
Current Transducer CTSR 1-P I PRN = 1A For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary (high power) and the secondary circuit (electronic circuit).
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NSM/SP33 series N = 8, 15, 25 A Ref: HO 8-NSM/SP33, HO 15-NSM/SP33, HO 25-NSM/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 205-S ULTRASTAB I PN = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature
More informationFor the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.
Voltage transducer V PN = 1 V Ref: DV 1/SP For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated
More informationTypical Application VCC IP+ ACS755 GND C F 3 R F
Features and Benefits Monolithic Hall IC for high reliability Single +5 V supply 3 kv RMS isolation voltage between terminals /5 and pins 1/2/3 for up to 1 minute 35 khz bandwidth Automotive temperature
More informationAUTOMOTIVE CURRENT TRANSDUCER CAB 300-C/SP2
Introduction AUTOMOTIVE CURRENT TRANSDUCER The CAB family is for battery monitoring applications where high accuracy and very low offset are required. Features Transducer using Fluxgate technology Zero
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NSM- SERIES I PN = 8, 15, 25 A Ref: HO 8-NSM-, HO 15-NSM-, HO 25-NSM- For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and
More informationCPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,
The CPCO Series (160mm) Current Probes are Clamp On current sensors capable of measuring ac and dc currents available in ranges of ±4000A ±8000A, ±12000A with an accuracy of +/-1% and non-linearity of
More informationCurrent transducer FHS 40-P/SP600
Current transducer I PM = 0-100 A Minisens transducer The Minisens transducer is an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle. It is suitable for
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer N = 6, 15, 25, 5 A Ref: LESR 6-NP, LESR 15-NP, LESR 25-NP, LESR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer LF 510-S I PN = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NP series I PN = 4, 6, 12, 15 Ref: HO 4-NP, HO 6-NP, HO 12-NP, HO 15-NP For the electronic measurement of current: DC, C, pulsed..., with galvanic separation between the primary and
More informationFor the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Voltage transducer DV V PN = V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Applications Bipolar and insulated
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LESR series N = 6, 15, 25, 5 A Ref: LESR 6-NP, LESR 15-NP, LESR 25-NP, LESR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer LF 1010-S/SPA2 I PN = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer LF 210-S/SP3 I PN = 100 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationUnipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI
Current Transducer DVL-UI series V PN = 50... 1500 V Unipolar voltage - Current output 4-0 ma Ref: DVL 50-UI, DVL 150-UI, DVL 50-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI For the electronic
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer ITC 2000-S/SP2 N = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationFor the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.
Voltage transducer V PN = 4 V Ref: DV 4/SP4 For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit. Features Bipolar and isolated
More information= 600 V. Voltage transducer DVM 600 V PN
Voltage transducer DVM 6 V PN = 6 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationIMC-Hall Current Sensor
CSA-1V IMC-Hall Current Sensor Features: IMC-Hall technology - Very high sensitivity due to integrated magnetic concentrator Sensitive to a magnetic field parallel to the chip surface Linear output voltage
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer LF 2010-S I PN = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More information= 1000 V. Voltage transducer DVC 1000-P V P N
Voltage transducer DVC 1-P V P N = 1 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationDL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.
DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer LF 510-S/SP13 I PN = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and
More informationI PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A
urrent Transducer ITZ 5000-SB FLEX ULTRASTAB I PM = 5000 A For ultra-high precision measurement of current: D, A, pulsed..., with galvanic separation between primary and secondary. Separate magnetic head
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
Current Transducer CTSR 0.6-TP/SP2 I PRN = 600 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Features
More informationDS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 0 ppm offset Current
More informationCurrent Sensor Solutions. Hall-IC based. Partners of SSG. Current sensors 2014 Seite: 1
Hall-IC based Current Sensor Solutions Current sensors 2014 Seite: 1 Hallsensor based current sensors 1 ACS-Modules Range: +/-5, 20, 50, 100, 150, 200A Fully Integrated system Quasi-closed magnetic loop
More informationDS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V
More informationV P N. Voltage transducer DVM 2000-B = 2000 V
Voltage transducer DVM 2-B V P N = 2 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationDS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 600A Features Linearity error maximum 1.5 ppm Fluxgate,
More informationAC/DC current clamps (1/2) E N series
AC/DC current clamps The clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. These clamps' narrow, elongated design makes them ideal areas
More informationDQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1000A Features Linearity error maximum 1 ppm Fluxgate,
More informationCPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A
The CPCO Series (160mm aperture) Current Probes are Clamp On current sensors capable of measuring ac and dc currents. The Current Probe splits along a diameter allowing easy installation to existing cables
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LF 2010-S/SPA7 I P N = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and
More informationDS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 370A Features Linearity error maximum 2 ppm 100
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LF 2010-S/SPA0 I P N = 2000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer ITL 4000-S I PN = 4000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I > 0 P Features Closed
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.
Current Transducer LF 510-S I P N = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit. Features Bipolar and insulated
More informationIntegrated Dual-Axis Gyro IDG-1215
Integrated Dual-Axis Gyro FEATURES Integrated X- and Y-axis gyros on a single chip ±67 /s full-scale range 15m/ /s sensitivity Integrated amplifiers and low-pass filter Auto Zero function Integrated reset
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer LF 21-S/SPA2 I P N = 2 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated
More informationLow Cost 100 g Single Axis Accelerometer with Analog Output ADXL190*
a FEATURES imems Single Chip IC Accelerometer 40 Milli-g Resolution Low Power ma 400 Hz Bandwidth +5.0 V Single Supply Operation 000 g Shock Survival APPLICATIONS Shock and Vibration Measurement Machine
More informationCYHCS-RC2S Split Core Hall Effect DC Current Sensor
Current Sensors CYHCS-RC2S Split Core Hall Effect DC Current Sensor This Hall Effect current sensor can be used for measurement of DC and AC current, pulsed currents etc. The output of the transducer reflects
More informationProduct Specification
Product Specification SCA620-EF8H1A SINGLE AXIS ACCELEROMETER WITH ANALOG INTERFACE The SCA620 accelerometer consists of a silicon bulk micro machined sensing element chip and a signal conditioning ASIC.
More information