1 632 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 51, NO. 3, JUNE 2004 Active Voltage Clamp in Flyback Converters Operating in CCM Mode Under Wide Load Variation Nikolaos P. Papanikolaou and Emmanuel C. Tatakis Abstract Active clamp topologies of low power dissipation have become a very attractive solution in order to limit overvoltages in flyback converters. Although many suitable topologies have been introduced for the case of discontinuous conduction mode (DCM), where the duty cycle value depends on the load level, in continuous conduction mode (CCM) it is more difficult to appropriately design such topologies so as to sense load changes due to the small duty cycle divergence under wide load variation. Taking for granted that in order to achieve high power-factor correction in these converters, CCM is a more attractive mode of operation, a drastic solution for this case that will manage to eliminate voltage stresses under wide load changes has become very essential. For this purpose, this paper presents an active clamp topology with small power dissipation, suitable for flyback converters operating in CCM mode. Its main idea is the use of a load-dependent current source, consisting of an auxiliary converter operating in DCM mode. Experimental results highlight the effectiveness of the proposed topology under wide load changes, establishing it as an appropriate solution in order to develop flyback converters, even at the power range of 500 W. Index Terms Active voltage clamp, flyback converter, snubbers. n d NOMENCLATURE Voltage clamp value. Transformer primary to secondary winding turns ratio of the main converter. Snubber power value (dissipative case). Snubber power value (nondissipative case). Snubber resistor. Maximum current value on inductor during ontime [discontinuous conduction mode (DCM)]. Constant switching frequency of the main converter. On time of the main converter. Duty cycle of the main converter. Discharging snubber inductance. Maximum current value on the primary winding of the main converter during on time. Power of the main primary inductance. Main converter primary inductance. Manuscript received June 28, 2002; revised October 30, Abstract published on the Internet January 14, The authors are with the Laboratory of Electromechanical Energy Conversion, Department of Electrical and Computer Engineering, University of Patras, Rion-Patras, Greece ( Papanik@ee.upatras.gr; E.C.Tatakis@ ee.upatras.gr). Digital Object Identifier /TIE Main converter primary leakage inductance. Auxiliary converter primary leakage inductance. Constant switching frequency of the auxiliary converter. Duty cycle of the auxiliary converter. Transformer primary to secondary winding turns ratio of the auxiliary converter. Zener voltage. Maximum permitted drain to source voltage value of the auxiliary switch. Lower current value of the leakage inductance (normally zero). I. INTRODUCTION THE flyback converter represents a widespread topology, suitable for the development of switch mode power supplies with multiple output voltages, due to the simplicity of its structure. Traditionally, the DCM of operation has been in favor, mainly due to its better dynamic behavior. Nowadays, however, where a lot of discussion has concerned the electromagnetic compatibility of electric and electronic devices [1] and many low-voltage applications that are supplied from the power network have emerged, continuous conduction mode (CCM) of operation has become more attractive, since it leads to higher harmonic regulation and lower power losses. As is well known, the main drawback of this converter is the existence of the transformer leakage inductance, whose value is at the range of 2% 10% of the main inductance; the resonance between this inductance and the parasitic capacitances of the semiconductive switches produces large voltage stresses as well as power losses, decreasing the converter efficiency. Furthermore, in the case of multiple outputs from a single flyback converter only, the cross regulation between the multiple transformer secondary windings is seriously affected by these high voltage spikes [7], complicating the construction of dc power supplies with multiple outputs. Thus, these facts prevent the use of this converter at higher power levels, where the forward and full-bridge alternatives are more preferable. Beyond that, in order to limit the voltage spikes on the controlled switch, an appropriate snubber is necessary. Many snubber topologies have been introduced for the flyback structure and for various power levels. The simplest of them (suitable for lower power levels) are the dissipative snubbers [2], where the leakage energy is led to a resistor /04$ IEEE

2 PAPANIKOLAOU AND TATAKIS: ACTIVE VOLTAGE CLAMP IN FLYBACK CONVERTERS 633 Fig. 1. Basic snubber topologies for flyback converter. However, several studies have highlighted the so-called nondissipative LC snubbers [3], [4]; the main idea of these kinds of snubbers is by using an auxiliary LC network either to force the leakage energy to oscillate among the input stage and the leakage inductance (and treat it as reactive power), or to transfer it to the load (and treat it as active power). In both cases the leakage energy is not dissipated to a resistor and so the power losses are decreased. Thus, this solution maximizes the efficiency and permits the use of the flyback converter at higher power levels. Nevertheless, the main drawback of snubbers, in general, is that their effectiveness depends strongly on line and load variations; they are usually sufficient for a narrow load range area and so their design in cases of large load variations becomes difficult. As it concerns the DCM operation, a nondissipative solution has been already presented in the literature [7], which sufficiently deals with these issues. However, in CCM mode the design difficulty increases due to the almost constant duty cycle under wide load changes (if the output voltage is constant) as well as the higher power level. For this purpose, an alternative low-loss active snubber topology will be studied in this paper, suitable for any flyback application including power-factor correction (PFC) and low-voltage supplying. The main idea of this solution is the use of an appropriate auxiliary converter as a controllable current source, so as to regulate the value of its processed power according to load variations. To this direction, a short discussion concerning the main drawbacks of the most popular snubber topologies will take place, highlighting the benefits of the active solution. Analytical presentation of the design procedure as well as experimental results will take place. II. STUDY OF BASIC SNUBBER TOPOLOGIES FOR FLYBACK CONVERTER The block diagrams of the basic snubber topologies for the case of flyback converter are shown in Fig. 1. The snubber in Fig. 1(a) is the least expensive solution; it introduces a damping factor in order to limit the peak voltage value during oscillation. Although simple, its operation depends strongly on load variation, while it is rather difficult to determine the most appropriate values of its elements, limiting its use at small power levels. On the other hand, the topologies of Fig. 1(b) and (c) are more suitable for higher power levels. Using these schemes, the maximum voltage value on the switch is clamped due to the leakage energy storage into voltage source. The snubber of Fig. 1(b) is a dissipative one, while the snubber of Fig. 1(c) is a nondissipative one. In the dissipative version, the voltage source can be consisted either of a parallel combination of a large electrolytic capacitor and a resistor, or it could be a single zener diode [5]. As it concerns the nondissipative case, can be implemented by a large electrolytic capacitor, leading to a constant voltage clamp, which is partially discharged through inductor during on time. This inductor operates in DCM mode and it can be constructed either by using a separate magnetic core (reactive power treatment), or it could be a third winding on the main transformer core transferring so its energy directly to the load (active power treatment). Moreover, an alternative operation mode has been presented, where the resonance frequency of the LC circuit is much higher than the switching frequency. However, this method leads to higher voltages across the semiconductive switch, whether the converter operates in CCM [6] or in DCM mode [7]. For this reason, this mode of operation will not be included in the following analysis. During the design of voltage clamp snubbers, it must be taken into account that the voltage source value should be as close as possible to the theoretical expected value across the primary transformer winding during off time [2] In this way, the voltage across the main switch becomes as small as possible, avoiding so the need for excessively high-voltage MOSFET devices. Of course, these two values cannot become equal, because this it would be a short circuit for the main flyback transformer inductance. Thus, the snubber design should reassure that the voltage source transfers the leakage energy to the resistor or to the inductance, under the desired voltage value. For the dissipative case, the power that is transferred to the resistor is while for the nondissipative case the power can be described as Due to snubber DCM operation, becomes Combining (3) and (4), the power in the nondissipative case can be rewritten as Obviously, the processed power in both cases should be equal to the leakage power. (1) (2) (3) (4) (5)

3 634 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 51, NO. 3, JUNE 2004 If we assume that the converter is in DCM mode, then the leakage power can be easily described as follows: (6) Similarly, the power of the main primary inductance is Finally, assuming unitary efficiency, the primary inductance power is transferred during off time to the load and, so, Using (6) (8), the leakage power finally becomes (7) (8) Since and should be equal under any load case, the dissipative version becomes less attractive: (2) shows that in order to achieve under any load case, changes according to the load. Thus, for wide load range the voltage value across the main switch becomes prohibitively high making this snubber less attractive. A good choice for wide load range though, seems to be the Zener alternative [5]: in this case the voltage clamp remains constant (due to the constant Zener voltage) under any load condition, making it a rather attractive solution in DCM operation. Similarly, the nondissipative solution is a good choice in DCM mode too: since depends on duty cycle value, which even for constant output voltage depends on the load level in DCM mode, this topology can be appropriately designed so as to meet wide load changes. In this way, both limitation of voltage stress and low power dissipation are achieved, leading to high efficiency. Of course, the cost increase makes it more suitable for power levels above 50 W. In CCM mode however, the snubber design has to deal with the additional fact that the duty cycle value changes slightly under wide load variations theoretically it does not depend on load change. According to (2) and (5), which stand for the dissipative and the nondissipative voltage clamp case, correspondingly, it is obvious that the voltage clamp value depends on the leakage power value as well as the duty cycle value. In DCM mode of operation, the duty cycle value changes as the output power changes, even if the output voltage remains constant. Thus, the change of the voltage clamp value can be kept sufficiently small in this mode of operation under constant output voltage value even if the load presents large variation (e.g. 10% 100% of its nominal value), due to the similar variation of the duty cycle value. For this mode of operation so, we are able to use solutions like those proposed in [3], [4] and in [6], [7], leading to excellent operational characteristics for the main converter. On the other hand, CCM mode of operation is much more complicated, concerning the design of such snubbers; in applications where the output voltage remains constant while the output power presents large variation, the duty cycle value remains almost constant. Thus, the clamp voltage value presents (9) Fig. 2. Equivalent circuit for the case of the load-dependent active clamp. large variation during these large output power changes, in order to absorb the leakage power the value of which changes with the load, for any snubber case like those mentioned in [3], [4] and in [6], [7], leading to high voltage values across the main switch. Even the use of ZVS-active voltage clamp techniques for this specific situation, also leads to high voltage values across the main switch, since the voltage clamp value that they develop changes linearly to the load level. Furthermore, the Zener diode solution becomes less attractive in CCM mode, due its high power level. The above analysis shows that an appropriate snubber for the CCM mode has to take into account load changes, by adjusting properly the energy that is transferred from voltage source to a dissipative resistor or to the input/output converter stage. This can be accomplished by developing a load-dependent current source, as it is shown in Fig. 2. In the following paragraph the appropriate modulation of this current source is discussed. III. CONSTRUCTION OF THE LOAD-DEPENDENT SNUBBER FOR FLYBACK CONVERTER OPERATING IN CCM As has been already mentioned, CCM operation is a rather convenient case for the development of EMC compatible flyback converters. This can be accomplished by using a PFC control technique for CCM operation [10]. Although in PFC converters the duty cycle value is a time function during a line half cycle [8], its average value depends only on the input (peak value) and the output voltages as well as on the transformer turns ratio value. Thus, similar to the dc/dc operation, the average duty cycle value is almost (due to the non-unitary efficiency) constant under load variations and so these two cases can be treated in the same way as it concerns the appropriate snubber design. The load-dependent snubber could be either dissipative or nondissipative. In the dissipative case, its structure has to include a variable load current-dependent resistor, which can be implemented by using a transistor, as shown in Fig. 3. In this way, the power dissipation of is adjusted during the converter operation, minimizing so the voltage stress on the main switch. Although this is a simple approach, the whole circuit

4 PAPANIKOLAOU AND TATAKIS: ACTIVE VOLTAGE CLAMP IN FLYBACK CONVERTERS 635 inductance are the same. Of course, this condition cannot be fulfilled, because this would be a short circuit for the main inductance. Nevertheless, in order to conclude to a simple expression, we may assume that those two current values are close enough, a fact that is true if the converter operates relatively close to the boundary between CCM and DCM modes. Thus, the power consumption of the auxiliary flyback converter can be expressed as (12) Fig. 3. Block diagram of the dissipative load-dependent snubber. becomes more complicated, while the leakage energy dissipation increases the total losses. Thus, this solution becomes less attractive, mainly due to the fact that the leakage energy is dissipated, even though an additional transistor is used. Thus, the most appropriate solution seems to be the leakage energy transfer to the input or to the output converter stage. This task calls for the use of an auxiliary converter with galvanic isolation, operating in DCM mode so as to behave as a controllable current source. Obviously, the topologies that are most appropriate are the forward and flyback schemes, due to the single controllable switch of their structure. However, the forward converter calls for two magnetic cores as well as for duty cycle values lower than 50%. This last limitation encumbers the efficient converter design under any load case. On the other hand, the flyback converter topology in DCM operation has a simple structure, while the duty cycle value can well exceed 50%. Fig. 4 shows the proposed load-dependent snubber topology, consisted of an auxiliary flyback converter in DCM mode. Of course, its main drawback is the presence of voltage spikes due to the leakage inductance of this converter; thus, its usability depends on the power losses increase due to the leakage energy reset. Obviously, this amount of power can be described by a relation similar to (9), where in this case stands for the power that is transferred from the voltage source to the load-dependent snubber (according to Fig. 2). Since the main flyback converter operates in CCM, its input current waveform becomes as it is shown in Fig. 5. According to this figure, the power that is transferred to the output stage via the primary inductance becomes (10) Additionally, for the leakage power we can modify (6) according to Fig. 6 as (11) Equations (10) and (11) show that (9) can be used in CCM as well, if the lower current values of the primary and the leakage Taking for granted that the leakage inductance in practical flyback converter applications is lower than 10% of the main inductance, we can assume from (12) that the total dissipation due to leakage presence becomes less than 1% of the output power and so a Zener diode dissipative snubber can be introduced. Thus, the wasted energy amount becomes almost insignificant, proving that the use of an auxiliary flyback converter in DCM is rather effective. Furthermore, since the leakage power of the main converter can be kept lower than 10% of the output power, it is feasible to use the flyback structure in CCM mode for power levels even higher than 500 W, where forward and bridge topologies are in favor. Thus, the use of the proposed load-dependent snubber implementation enables the realization of simple switch mode power supplies for a wide power range. At this point, it is worth mentioning that a similar flyback topology has been already used for the case of a forward converter [9], in order to reset the main transformer inductance. However, in this case the voltage across the main switch of the forward converter is a time function whose maximum value depends on the load current. Thus, the whole philosophy of this snubber topology is completely different from the philosophy of the proposed one in the present work, where the voltage across the main switch is kept constant under any load condition. Finally, it is worth mentioning that since the auxiliary converter operates in DCM mode, its dynamic behavior is very good and so it does not have any practical impact on the main converter response under transient conditions. Furthermore, as it is obvious from Fig. 4, in case of short circuit at the output stage the duty cycle of the auxiliary converter becomes zero (since becomes zero) and so it does not contribute to the short circuit current. IV. DESIGN SCHEME OF THE PROPOSED LOAD-DEPENDENT SNUBBER As it is obvious from Fig. 4, an appropriate selection of the proposed snubber basic elements has to be done in order to cover any load condition. As it has been already mentioned, the main converter leakage power can be transferred to the input or output stages or even to the control circuit, depending on its level. However, according to Fig. 4, for the present approach it is assumed that this energy is transferred to the output stage and so it is treated as active power. Beyond that, the output voltage value is assumed constant; although this snubber can be used for variable output voltage as well, the most critical case is that of the constant output (constant duty cycle) voltage value. Thus, if the snubber is appropriately designed for the

5 636 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 51, NO. 3, JUNE 2004 Fig. 4. Proposed load-dependent snubber topology, consisting of an auxiliary flyback converter in DCM. Fig. 5. Flyback converter input current waveform under CCM operation. Fig. 6. Flyback converter primary leakage current waveform under CCM operation, assuming the use of the load-dependent active snubber. maximum output voltage value, its performance is satisfactory for lower voltage values (due to lower duty cycle values of the main converter). Considering now the snubber design, the first assumption that has to be done is that is close to. The auxiliary converter maximum power level can be estimated from (9), if we first measure the primary leakage and main inductance of the main converter. Furthermore, the power dissipation of the auxiliary converter can be expressed by using of (5) as follows: (13)

6 PAPANIKOLAOU AND TATAKIS: ACTIVE VOLTAGE CLAMP IN FLYBACK CONVERTERS 637 Fig. 7. Block diagram of the PFC control technique that has been implemented. Equation (13) shows that by using a duty cycle value for the maximum load case beyond 50%, the danger of duty cycle value less than 10% for the lower load case is overcome. Combining (9) and (13), we conclude to the following relation for : (14) Moreover, the auxiliary transformer turns ratio has to be selected in such a way, so as to reassure discontinuous conduction. This can be fulfilled if the following relation is true [2]: Taking into account that, (15) becomes (15) (16) Furthermore, the maximum voltage across the auxiliary transistor is (17) Thus, during the selection of both and it has also to be taken into account the desired voltage level across the auxiliary transistor. Finally, after the final transformer construction and by using (12), we are able to select the appropriate power level of the zener diode, by measuring the leakage inductance of the second transformer too, although in general it can be determined as 1% 2% of the maximum output power. As it concerns its Zener voltage, this has to be selected higher than the expected value from (17) and lower than the maximum permitted drain source voltage value of the auxiliary MOSFET [5] (18) Equations (14) and (16) (18) comprise the design tool of the proposed snubber for any load case. In particular, when the main flyback converter is used as a power-factor preregulator, the use of this active voltage suppressor becomes very essential, due to the high peak input voltage. To this specific application, the design equations can be used considering the average dc/dc converter model, where the input voltage is constant and equal to the average rectified mains voltage. Furthermore, for low-voltage application cases, the auxiliary converter free whiling diode can be replaced by a Schottky diode in order to limit the voltage drop. The introduction of synchronous rectification is not necessary, due to the low power level of the auxiliary converter stage. Nevertheless, for practical low voltage applications the optimum solution seems to be the use of the leakage energy in order to supply the control circuit, minimizing so the converter components and improving the total efficiency. V. EXPERIMENTAL RESULTS The proposed active clamp was implemented for the case of an experimental PFC flyback converter in CCM mode, with 3.0 V low output voltage. The PFC technique that has been implemented (its block diagram is exhibited in Fig. 7) is analytically presented in [8]. Due to the low output voltage value, synchronous rectification has been introduced in its structure. Although the leakage energy could be led to the control circuit, due to the power level of the specific application, the alternative of transferring it to the load has been selected so as to validate the above design strategy. The main characteristics of this converter, as well as the selected components of the auxiliary fly-

7 638 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 51, NO. 3, JUNE 2004 back converter according to the design procedure of the previous paragraph have been evaluated as follows: Parameter Value Main converter operational 220-Vrms 50-Hz mains characteristics supply, 3.0-V/ A dc output, 200-kHz constant Maximum theoretical expected voltage on the main converter primary switch Maximum selected voltage on the auxiliary switch switching frequency. V., the maximum mains voltage value,, V mh. 100 V. By selecting the maximum voltage value at 500 V, we are able to use MOSFET devices of lower cost (600-V breakdown voltage). 60, according to (17), where V,, V. Maximum permitted value 0.65, according to (16). Selected value 0.5, in order to be able to deal with large load variations (10% 100% of the maximum load). Selected value although the main converter frequency can be used, we select a much lower one (25 khz), in order to highlight the fact that the auxiliary converter design does not affect the main converter operation mh, according to (14). 7.6% (measured). 10% (measured). Zener power dissipation 0.21 W at maximum load, according to (12). Zener selected voltage 300 V, according to (18). 400 V, according to (17). In order to verify the effectiveness of the designed active snubber, the whole system was initially tested with low input dc voltage. Fig. 8 shows the voltage across the main converter switch with and without using the proposed active clamp, for 50-V/300-mV input/output voltage value, 1.0-A output current value, and 20-kHz switching frequency. Obviously, the use of the auxiliary converter leads to drastic overvoltage suppression, reassuring the safe converter operation at high voltages. Moreover, the converter was additionally tested with 300-V dc input voltage at maximum load (3.0 V 10 A), in order to verify that during its operation as a power factor preregulator the voltage across the main converter will be well below 500 V. Fig. 9 shows the voltage and current waveforms at the primary switch, for 300-V/3.0-V dc input/output voltage value, at 200 khz constant switching frequency and at maximum load. This experimental result proves that the maximum voltage value at the primary switch remains slightly above 400 V, reassuring the converter safe operation as a power-factor preregulator. Fig. 8. Primary switch voltage and output voltage waveforms of the experimental flyback converter (a) without using a snubber and (b) with the use of the proposed active snubber, for 50-V constant input voltage and 300-mV 1.0-A output characteristics (20-kHz main converter switching frequency). Fig. 9. Primary switch voltage (upper) and current (lower) waveforms, under 300-V constant input voltage and at maximum load (3.0 V 10 A), f =200kHz.

8 PAPANIKOLAOU AND TATAKIS: ACTIVE VOLTAGE CLAMP IN FLYBACK CONVERTERS 639 Fig. 10. Main converter input current and voltage waveforms (without using an RF input filter) at maximum load. Fig. 12. Auxiliary converter primary transformer winding voltage (upper) and current (lower) waveforms at maximum load. Fig. 11. Main converter input current waveform (lower) and voltage waveform (upper) across the snubber capacitor (V ) at maximum load. Fig. 13. Auxiliary converter secondary transformer winding voltage (upper) and current (lower) waveforms at maximum load. Since the above experimental procedure had shown the effectiveness of the proposed snubber, the converter was finally tested as a PFC topology with low output voltage. Fig. 10 shows the input current and voltage waveform (without using an input RF filter) for the maximum load case, while Fig. 11 shows the input current and the voltage across the snubber capacitor. These results highlight the fact that the proposed active clamp topology does not affect the main converter operation, while it manages to keep the primary switch voltage sufficiently close to its theoretical expected value. Thus, the whole structure produces less electromagnetic interference and so it can be easier integrated into the same board with its control circuit. Furthermore, Fig. 12 shows the input current and the primary winding voltage waveforms, while Fig. 13 shows the secondary winding voltage and current waveforms, for the case of the auxiliary converter and for maximum load. The results that are exhibited in these two figures verify the design procedure of the auxiliary flyback. Beyond that, the overvoltage suppression due to Zener diode reverse conduct is obvious in Fig. 13. Finally, Fig. 14 shows the converter efficiency as a function of the load ( is the maximum output current value), compared to the efficiency of an experimental conventional dc power supply, consisted of two converter stages a forward converter that steps down the rectified mains voltage and a buck dc/dc converter with synchronous rectification that produces 3.0-V output dc voltage. The conventional dc power supply operates at the same power level and with the same switching frequency with the experimental single-stage flyback converter. The reason of this comparison is to examine whether the flyback converter efficiency is at an acceptable level. Therefore, by studying Fig. 14, we can conclude that the flyback converter efficiency is at a very high level indeed, since the conventional converter exhibits lower efficiency under any dc-link voltage value, leading to an efficiency improvement of at least 15% at maximum load. Although many double-stage alternatives could be used instead of the series combination of a forward and a buck converter, the efficiency improvement by using the single stage flyback converter would also be noticeable. Thus, the proposed snubber is

9 640 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 51, NO. 3, JUNE 2004 Fig. 14. Flyback converter efficiency compared to the two converter stages total efficiency, as a function of the load current and the dc voltage link of the two stages. proved to be almost nondissipative, while the large overvoltage suppression contributes to a high total efficiency level. Furthermore, the proposed snubber, as shown in Fig. 10, does not affect the PFC operation since it does not use the main flyback switch for its discharge and so it does not lead to excessive losses and current stresses. Another important advantage is that the voltage spikes elimination contributes to good cross regulation and so it eases the development of multiple dc outputs from a single transformer core, maximizing so the power density. Finally, the overvoltage suppression enables the use of lower voltage transistors reducing the cost. VI. CONCLUSION An alternative active clamptopologyforflyback converters operating in CCM mode has been presented. The main idea of this structure is the introduction of a load-dependent current source that transfers the leakage energy to the input/output stage or even to the control circuit, depending on the converter power level. Experimental results concerning the performance of the proposed topology have been exhibited, verifying its low power consumption and the large overvoltage suppression that it achieves, leading the main flyback converter to a high efficiency level even for the cases of power-factor preregulation and low-voltage supplying. REFERENCES [1] A. Zuccato and L. Rossetto, Understanding and complying with CISPR and IEC 1000 standards on EMC, presented at the EPE 97, Trondheim, Norway, Sept [2] K. H. Billings, Handbook of Switchmode Power Supplies. New York: McGraw-Hill, [3] T. Ninomiya, T. Tanaka, and K. Harada, Analysis and optimization of a nondissipative LC turn-off snubber, IEEE Trans. Power Electron., vol. 3, pp , Apr [4] S. B. Yaakov and G. Ivensky, Passive lossless snubbers for high frequency PWM converters, presented at the IEEE APEC 99, Dallas, TX, Mar [5] ZenBlock: Zener with integrated blocking diode, Philips Semiconductors, Eindhoven, The Netherlands, Applicat. Note, [6] G. Spiazzi, S. Buso, and D. Tagliavia, A low-loss high-power-factor flyback rectifier for smart power integration, in Proc. IEEE PESC 00, Galway, Ireland, June 2000, pp [7] C.Chuanwen Ji, K. M.K. Mark Smith, and K. M.Keyue M. Smedley, Cross regulation in flyback converters: Solutions, in Proc. IEEE IECON 99, vol. 1, San Jose, CA, Nov. 1999, pp [8] N. P. Papanikolaou, E. J. Rikos, and E. C. Tatakis, A novel technique for high power factor correction in flyback converters: Theoretical analysis and design guidelines, Proc. IEE Elect. Power Applicat., vol. 148, no. 2, pp , Mar [9] G. A. Karvelis, M. D. Manolarou, P. Malatestas, and S. N. Manias, Analysis and design of nondissipative active clamp for forward converters, Proc. IEE Elect. Power Applicat., vol. 148, no. 5, pp , Sept [10] L. Rossetto, G. Spiazzi, and P. Tenti, Control techniques for power factor correction converters, in Proc. PEMC 94, Warsaw, Poland, Sept , 1994, pp Nikolaos P. Papanikolaou received the Dipl. Eng. and Ph.D. degrees in electrical engineering from the University of Patras, Rion-Patras, Greece, in 1998 and 2002, respectively. He is currently a Post-Doctoral Researcher in the Department of Electrical and Computer Engineering, University of Patras. His research interests are focused on power quality improvement issues. Emmanuel C. Tatakis was born in Alexandria, Egypt, in He received the Electrical Engineering Dipl. degree from the University of Patras, Rion-Patras, Greece, in 1981, and the Ph.D. degree in applied sciences from the University of Brussels, Brussels, Belgium, in He is currently an Assistant Professor in the Department of Electrical and Computer Engineering, University of Patras. His teaching activities include power electronics and electrical machines. His research interests include switch-mode power supplies, resonant converters, power-factor correction, electrical drive systems, photovoltaic systems, educational methods on electrical machines, and power electronics. Dr. Tatakis is Member of the European Electronics Association, Société Royale Belge des Electriciens, and Technical Chamber of Greece.

IN THE high power isolated dc/dc applications, full bridge

IN THE high power isolated dc/dc applications, full bridge 354 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 21, NO. 2, MARCH 2006 A Novel Zero-Current-Transition Full Bridge DC/DC Converter Junming Zhang, Xiaogao Xie, Xinke Wu, Guoliang Wu, and Zhaoming Qian,

More information

NEW microprocessor technologies demand lower and lower

NEW microprocessor technologies demand lower and lower IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 41, NO. 5, SEPTEMBER/OCTOBER 2005 1307 New Self-Driven Synchronous Rectification System for Converters With a Symmetrically Driven Transformer Arturo Fernández,

More information

NOWADAYS, it is not enough to increase the power

NOWADAYS, it is not enough to increase the power IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 44, NO. 5, OCTOBER 1997 597 An Integrated Battery Charger/Discharger with Power-Factor Correction Carlos Aguilar, Student Member, IEEE, Francisco Canales,

More information

MODERN switching power converters require many features

MODERN switching power converters require many features IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 19, NO. 1, JANUARY 2004 87 A Parallel-Connected Single Phase Power Factor Correction Approach With Improved Efficiency Sangsun Kim, Member, IEEE, and Prasad

More information

A Double ZVS-PWM Active-Clamping Forward Converter: Analysis, Design, and Experimentation

A Double ZVS-PWM Active-Clamping Forward Converter: Analysis, Design, and Experimentation IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 16, NO. 6, NOVEMBER 2001 745 A Double ZVS-PWM Active-Clamping Forward Converter: Analysis, Design, and Experimentation René Torrico-Bascopé, Member, IEEE, and

More information

466 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 3, MAY A Single-Switch Flyback-Current-Fed DC DC Converter

466 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 3, MAY A Single-Switch Flyback-Current-Fed DC DC Converter 466 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 13, NO. 3, MAY 1998 A Single-Switch Flyback-Current-Fed DC DC Converter Peter Mantovanelli Barbosa, Member, IEEE, and Ivo Barbi, Senior Member, IEEE Abstract

More information

IN A CONTINUING effort to decrease power consumption

IN A CONTINUING effort to decrease power consumption 184 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 14, NO. 1, JANUARY 1999 Forward-Flyback Converter with Current-Doubler Rectifier: Analysis, Design, and Evaluation Results Laszlo Huber, Member, IEEE, and

More information

High-Efficiency Forward Transformer Reset Scheme Utilizes Integrated DC-DC Switcher IC Function

High-Efficiency Forward Transformer Reset Scheme Utilizes Integrated DC-DC Switcher IC Function High-Efficiency Forward Transformer Reset Scheme Utilizes Integrated DC-DC Switcher IC Function Author: Tiziano Pastore Power Integrations GmbH Germany Abstract: This paper discusses a simple high-efficiency

More information

S. General Topological Properties of Switching Structures, IEEE Power Electronics Specialists Conference, 1979 Record, pp , June 1979.

S. General Topological Properties of Switching Structures, IEEE Power Electronics Specialists Conference, 1979 Record, pp , June 1979. Problems 179 [22] [23] [24] [25] [26] [27] [28] [29] [30] J. N. PARK and T. R. ZALOUM, A Dual Mode Forward/Flyback Converter, IEEE Power Electronics Specialists Conference, 1982 Record, pp. 3-13, June

More information

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor 770 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 48, NO. 4, AUGUST 2001 A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor Chang-Shiarn Lin, Member, IEEE, and Chern-Lin

More information

Soft switching of multioutput flyback converter with active clamp circuit

Soft switching of multioutput flyback converter with active clamp circuit Soft switching of multioutput flyback converter with active clamp circuit Aruna N S 1, Dr S G Srivani 2, Balaji P 3 PG Student, Dept. of EEE, R.V. College of Engineering, Bangalore, Karnataka, India 1

More information

Conducted EMI Issues in a 600-W Single-Phase Boost PFC Design

Conducted EMI Issues in a 600-W Single-Phase Boost PFC Design 578 IEEE TRANSACTIONS ON INDUSTRY APPLICATION, VOL. 36, NO. 2, MARCH/APRIL 2000 Conducted EMI Issues in a 600-W Single-Phase Boost PFC Design Leopoldo Rossetto, Member, IEEE, Simone Buso, Member, IEEE,

More information

THE converter usually employed for single-phase power

THE converter usually employed for single-phase power 82 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 46, NO. 1, FEBRUARY 1999 A New ZVS Semiresonant High Power Factor Rectifier with Reduced Conduction Losses Alexandre Ferrari de Souza, Member, IEEE,

More information

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR Josna Ann Joseph 1, S.Bella Rose 2 PG Scholar, Karpaga Vinayaga College of Engineering and Technology, Chennai 1 Professor, Karpaga Vinayaga

More information

GENERALLY, a single-inductor, single-switch boost

GENERALLY, a single-inductor, single-switch boost IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 19, NO. 1, JANUARY 2004 169 New Two-Inductor Boost Converter With Auxiliary Transformer Yungtaek Jang, Senior Member, IEEE, Milan M. Jovanović, Fellow, IEEE

More information

Novel Zero-Current-Switching (ZCS) PWM Switch Cell Minimizing Additional Conduction Loss

Novel Zero-Current-Switching (ZCS) PWM Switch Cell Minimizing Additional Conduction Loss IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 49, NO. 1, FEBRUARY 2002 165 Novel Zero-Current-Switching (ZCS) PWM Switch Cell Minimizing Additional Conduction Loss Hang-Seok Choi, Student Member, IEEE,

More information

ENERGY saving through efficient equipment is an essential

ENERGY saving through efficient equipment is an essential IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 61, NO. 9, SEPTEMBER 2014 4649 Isolated Switch-Mode Current Regulator With Integrated Two Boost LED Drivers Jae-Kuk Kim, Student Member, IEEE, Jae-Bum

More information

A Novel Technique to Reduce the Switching Losses in a Synchronous Buck Converter

A Novel Technique to Reduce the Switching Losses in a Synchronous Buck Converter A Novel Technique to Reduce the Switching Losses in a Synchronous Buck Converter A. K. Panda and Aroul. K Abstract--This paper proposes a zero-voltage transition (ZVT) PWM synchronous buck converter, which

More information

An Application of Soft Switching for Efficiency Improvement in ZVT-PWM Converters

An Application of Soft Switching for Efficiency Improvement in ZVT-PWM Converters An Application of Soft Switching for Efficiency Improvement in ZVT-PWM Converters 1 Shivaraj Kumar H.C, 2 Noorullah Sherif, 3 Gourishankar C 1,3 Asst. Professor, EEE SECAB.I.E.T Vijayapura 2 Professor,

More information

High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit

High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit RESEARCH ARTICLE OPEN ACCESS High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit C. P. Sai Kiran*, M. Vishnu Vardhan** * M-Tech (PE&ED) Student, Department of EEE, SVCET,

More information

Improving Passive Filter Compensation Performance With Active Techniques

Improving Passive Filter Compensation Performance With Active Techniques IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 50, NO. 1, FEBRUARY 2003 161 Improving Passive Filter Compensation Performance With Active Techniques Darwin Rivas, Luis Morán, Senior Member, IEEE, Juan

More information

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation 638 Progress In Electromagnetics Research Symposium 2006, Cambridge, USA, March 26-29 A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation A. K.

More information

IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 21, NO. 1, JANUARY

IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 21, NO. 1, JANUARY IEEE TRANSACTIONS ON POWER ELECTRONICS, OL. 21, NO. 1, JANUARY 2006 73 Maximum Power Tracking of Piezoelectric Transformer H Converters Under Load ariations Shmuel (Sam) Ben-Yaakov, Member, IEEE, and Simon

More information

Impact of inductor current ringing in DCM on output voltage of DC-DC buck power converters

Impact of inductor current ringing in DCM on output voltage of DC-DC buck power converters ARCHIVES OF ELECTRICAL ENGINEERING VOL. 66(2), pp. 313-323 (2017) DOI 10.1515/aee-2017-0023 Impact of inductor current ringing in DCM on output voltage of DC-DC buck power converters MARCIN WALCZAK Department

More information

Comparative Analysis of Power Factor Correction Techniques for AC/DC Converter at Various Loads

Comparative Analysis of Power Factor Correction Techniques for AC/DC Converter at Various Loads ISSN 2393-82 Vol., Issue 2, October 24 Comparative Analysis of Power Factor Correction Techniques for AC/DC Converter at Various Loads Nikita Kolte, N. B. Wagh 2 M.Tech.Research Scholar, PEPS, SDCOE, Wardha(M.S.),India

More information

K.Vijaya Bhaskar. Dept of EEE, SVPCET. AP , India. S.P.Narasimha Prasad. Dept of EEE, SVPCET. AP , India.

K.Vijaya Bhaskar. Dept of EEE, SVPCET. AP , India. S.P.Narasimha Prasad. Dept of EEE, SVPCET. AP , India. A Closed Loop for Soft Switched PWM ZVS Full Bridge DC - DC Converter S.P.Narasimha Prasad. Dept of EEE, SVPCET. AP-517583, India. Abstract: - This paper propose soft switched PWM ZVS full bridge DC to

More information

A New Soft Recovery PWM Quasi-Resonant Converter With a Folding Snubber Network

A New Soft Recovery PWM Quasi-Resonant Converter With a Folding Snubber Network 456 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 49, NO. 2, APRIL 2002 A New Soft Recovery PWM Quasi-Resonant Converter With a Folding Snubber Network Jin-Kuk Chung, Student Member, IEEE, and Gyu-Hyeong

More information

Evaluation of Two-Stage Soft-Switched Flyback Micro-inverter for Photovoltaic Applications

Evaluation of Two-Stage Soft-Switched Flyback Micro-inverter for Photovoltaic Applications Evaluation of Two-Stage Soft-Switched Flyback Micro-inverter for Photovoltaic Applications Sinan Zengin and Mutlu Boztepe Ege University, Electrical and Electronics Engineering Department, Izmir, Turkey

More information

A Highly Versatile Laboratory Setup for Teaching Basics of Power Electronics in Industry Related Form

A Highly Versatile Laboratory Setup for Teaching Basics of Power Electronics in Industry Related Form A Highly Versatile Laboratory Setup for Teaching Basics of Power Electronics in Industry Related Form JOHANN MINIBÖCK power electronics consultant Purgstall 5 A-3752 Walkenstein AUSTRIA Phone: +43-2913-411

More information

POWERED electronic equipment with high-frequency inverters

POWERED electronic equipment with high-frequency inverters IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II: EXPRESS BRIEFS, VOL. 53, NO. 2, FEBRUARY 2006 115 A Novel Single-Stage Power-Factor-Correction Circuit With High-Frequency Resonant Energy Tank for DC-Link

More information

Topologies for Optimizing Efficiency, EMC and Time to Market

Topologies for Optimizing Efficiency, EMC and Time to Market LED Power Supply Topologies Topologies for Optimizing Efficiency, EMC and Time to Market El. Ing. Tobias Hofer studied electrical engineering at the ZBW St. Gallen. He has been working for Negal Engineering

More information

Novel Passive Snubber Suitable for Three-Phase Single-Stage PFC Based on an Isolated Full-Bridge Boost Topology

Novel Passive Snubber Suitable for Three-Phase Single-Stage PFC Based on an Isolated Full-Bridge Boost Topology 264 Journal of Power Electronics, Vol. 11, No. 3, May 2011 JPE 11-3-3 Novel Passive Snubber Suitable for Three-Phase Single-Stage PFC Based on an Isolated Full-Bridge Boost Topology Tao Meng, Hongqi Ben,

More information

A Merged Interleaved Flyback PFC Converter with Active Clamp and ZVZCS

A Merged Interleaved Flyback PFC Converter with Active Clamp and ZVZCS A Merged Interleaved Flyback PFC Converter with Active Clamp and ZVZCS Mehdi Alimadadi, William Dunford Department of Electrical and Computer Engineering University of British Columbia (UBC), Vancouver,

More information

Comparison Between two Single-Switch Isolated Flyback and Forward High-Quality Rectifiers for Low Power Applications

Comparison Between two Single-Switch Isolated Flyback and Forward High-Quality Rectifiers for Low Power Applications Comparison Between two ingle-witch Isolated Flyback and Forward High-Quality Rectifiers for Low Power Applications G. piazzi,. Buso Department of Electronics and Informatics - University of Padova Via

More information

A New Soft Switching PWM DC-DC Converter with Auxiliary Circuit and Centre-Tapped Transformer Rectifier

A New Soft Switching PWM DC-DC Converter with Auxiliary Circuit and Centre-Tapped Transformer Rectifier Available online at www.sciencedirect.com Procedia Engineering 53 ( 2013 ) 241 247 Malaysian Technical Universities Conference on Engineering & Technology 2012, MUCET 2012 Part 1- Electronic and Electrical

More information

Constant-Frequency Soft-Switching Converters. Soft-switching converters with constant switching frequency

Constant-Frequency Soft-Switching Converters. Soft-switching converters with constant switching frequency Constant-Frequency Soft-Switching Converters Introduction and a brief survey Active-clamp (auxiliary-switch) soft-switching converters, Active-clamp forward converter Textbook 20.4.2 and on-line notes

More information

새로운무손실다이오드클램프회로를채택한두개의트랜스포머를갖는영전압스위칭풀브릿지컨버터

새로운무손실다이오드클램프회로를채택한두개의트랜스포머를갖는영전압스위칭풀브릿지컨버터 새로운무손실다이오드클램프회로를채택한두개의트랜스포머를갖는영전압스위칭풀브릿지컨버터 윤현기, 한상규, 박진식, 문건우, 윤명중한국과학기술원 Zero-Voltage Switching Two-Transformer Full-Bridge PWM Converter With Lossless Diode-Clamp Rectifier H.K. Yoon, S.K. Han, J.S.

More information

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS CHAPTER 3. SINGLE-STAGE PFC TOPOLOG GENERALIATION AND VARIATIONS 3.1. INTRODUCTION The original DCM S 2 PFC topology offers a simple integration of the DCM boost rectifier and the PWM DC/DC converter.

More information

SINGLE-STAGE HIGH-POWER-FACTOR SELF-OSCILLATING ELECTRONIC BALLAST FOR FLUORESCENT LAMPS WITH SOFT START

SINGLE-STAGE HIGH-POWER-FACTOR SELF-OSCILLATING ELECTRONIC BALLAST FOR FLUORESCENT LAMPS WITH SOFT START SINGLE-STAGE HIGH-POWER-FACTOR SELF-OSCILLATING ELECTRONIC BALLAST FOR FLUORESCENT S WITH SOFT START Abstract: In this paper a new solution to implement and control a single-stage electronic ballast based

More information

INVESTIGATION OF GATE DRIVERS FOR SNUBBERLESS OVERVOLTAGE SUPPRESSION OF POWER IGBTS

INVESTIGATION OF GATE DRIVERS FOR SNUBBERLESS OVERVOLTAGE SUPPRESSION OF POWER IGBTS INVESTIGATION OF GATE DRIVERS FOR SNUBBERLESS OVERVOLTAGE SUPPRESSION OF POWER IGBTS Alvis Sokolovs, Iļja Galkins Riga Technical University, Department of Power and Electrical Engineering Kronvalda blvd.

More information

MOST electrical systems in the telecommunications field

MOST electrical systems in the telecommunications field IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 46, NO. 2, APRIL 1999 261 A Single-Stage Zero-Voltage Zero-Current-Switched Full-Bridge DC Power Supply with Extended Load Power Range Praveen K. Jain,

More information

THE classical solution of ac dc rectification using a fullwave

THE classical solution of ac dc rectification using a fullwave 630 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 44, NO. 5, OCTOBER 1997 The Discontinuous Conduction Mode Sepic and Ćuk Power Factor Preregulators: Analysis and Design Domingos Sávio Lyrio Simonetti,

More information

A Novel Concept in Integrating PFC and DC/DC Converters *

A Novel Concept in Integrating PFC and DC/DC Converters * A Novel Concept in Integrating PFC and DC/DC Converters * Pit-Leong Wong and Fred C. Lee Center for Power Electronics Systems The Bradley Department of Electrical and Computer Engineering Virginia Polytechnic

More information

Designers Series XII. Switching Power Magazine. Copyright 2005

Designers Series XII. Switching Power Magazine. Copyright 2005 Designers Series XII n this issue, and previous issues of SPM, we cover the latest technologies in exotic high-density power. Most power supplies in the commercial world, however, are built with the bread-and-butter

More information

ZCS-PWM Converter for Reducing Switching Losses

ZCS-PWM Converter for Reducing Switching Losses IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 9, Issue 1 Ver. III (Jan. 2014), PP 29-35 ZCS-PWM Converter for Reducing Switching Losses

More information

RECENTLY, the harmonics current in a power grid can

RECENTLY, the harmonics current in a power grid can IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 23, NO. 2, MARCH 2008 715 A Novel Three-Phase PFC Rectifier Using a Harmonic Current Injection Method Jun-Ichi Itoh, Member, IEEE, and Itsuki Ashida Abstract

More information

Half bridge converter with LCL filter for battery charging application using DC-DC converter topology

Half bridge converter with LCL filter for battery charging application using DC-DC converter topology Half bridge converter with LCL filter for battery charging application using DC-DC converter topology Manasa.B 1, Kalpana S 2 Assistant Professor Department of Electrical and Electronics PESITM, Shivamogga

More information

Alternated duty cycle control method for half-bridge DC-DC converter

Alternated duty cycle control method for half-bridge DC-DC converter HAIT Journal of Science and Engineering B, Volume 2, Issues 5-6, pp. 581-593 Copyright C 2005 Holon Academic Institute of Technology CHAPTER 3. CONTROL IN POWER ELEC- TRONIC CIRCUITS Alternated duty cycle

More information

Power Factor Correction for Chopper Fed BLDC Motor

Power Factor Correction for Chopper Fed BLDC Motor ISSN No: 2454-9614 Power Factor Correction for Chopper Fed BLDC Motor S.Dhamodharan, D.Dharini, S.Esakki Raja, S.Steffy Minerva *Corresponding Author: S.Dhamodharan E-mail: esakkirajas@yahoo.com Department

More information

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 12, Issue 3 Ver. IV (May June 2017), PP 68-76 www.iosrjournals.org Sepic Topology Based High

More information

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES 47 CHAPTER 3 DC-DC CONVERTER TOPOLOGIES 3.1 INTRODUCTION In recent decades, much research efforts are directed towards finding an isolated DC-DC converter with high volumetric power density, low electro

More information

Implementation of an Interleaved High-Step-Up Dc-Dc Converter with A Common Active Clamp

Implementation of an Interleaved High-Step-Up Dc-Dc Converter with A Common Active Clamp International Journal of Engineering Science Invention ISSN (Online): 2319 6734, ISSN (Print): 2319 6726 Volume 2 Issue 5 ǁ May. 2013 ǁ PP.11-19 Implementation of an Interleaved High-Step-Up Dc-Dc Converter

More information

Application Note, V1.1, Apr CoolMOS TM. AN-CoolMOS-08 SMPS Topologies Overview. Power Management & Supply. Never stop thinking.

Application Note, V1.1, Apr CoolMOS TM. AN-CoolMOS-08 SMPS Topologies Overview. Power Management & Supply. Never stop thinking. Application Note, V1.1, Apr. 2002 CoolMOS TM AN-CoolMOS-08 Power Management & Supply Never stop thinking. Revision History: 2002-04 V1.1 Previous Version: V1.0 Page Subjects (major changes since last revision)

More information

THE TWO TRANSFORMER active reset circuits presented

THE TWO TRANSFORMER active reset circuits presented 698 IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I: FUNDAMENTAL THEORY AND APPLICATIONS, VOL. 44, NO. 8, AUGUST 1997 A Family of ZVS-PWM Active-Clamping DC-to-DC Converters: Synthesis, Analysis, Design, and

More information

High Voltage-Boosting Converter with Improved Transfer Ratio

High Voltage-Boosting Converter with Improved Transfer Ratio Electrical and Electronic Engineering 2017, 7(2): 28-32 DOI: 10.5923/j.eee.20170702.04 High Voltage-Boosting Converter with Improved Transfer Ratio Rahul V. A. *, Denita D Souza, Subramanya K. Department

More information

ACEEE Int. J. on Control System and Instrumentation, Vol. 02, No. 02, June 2011

ACEEE Int. J. on Control System and Instrumentation, Vol. 02, No. 02, June 2011 A New Active Snubber Circuit for PFC Converter Burak Akýn Yildiz Technical University/Electrical Engineering Department Istanbul TURKEY Email: bakin@yildizedutr ABSTRACT In this paper a new active snubber

More information

A Quadratic Buck Converter with Lossless Commutation

A Quadratic Buck Converter with Lossless Commutation 264 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 47, NO. 2, APRIL 2000 A Quadratic Buck Converter with Lossless Commutation Vincius Miranda Pacheco, Acrísio José do Nascimento, Jr., Valdeir José Farias,

More information

Conventional Single-Switch Forward Converter Design

Conventional Single-Switch Forward Converter Design Maxim > Design Support > Technical Documents > Application Notes > Amplifier and Comparator Circuits > APP 3983 Maxim > Design Support > Technical Documents > Application Notes > Power-Supply Circuits

More information

CONTENTS. Chapter 1. Introduction to Power Conversion 1. Basso_FM.qxd 11/20/07 8:39 PM Page v. Foreword xiii Preface xv Nomenclature

CONTENTS. Chapter 1. Introduction to Power Conversion 1. Basso_FM.qxd 11/20/07 8:39 PM Page v. Foreword xiii Preface xv Nomenclature Basso_FM.qxd 11/20/07 8:39 PM Page v Foreword xiii Preface xv Nomenclature xvii Chapter 1. Introduction to Power Conversion 1 1.1. Do You Really Need to Simulate? / 1 1.2. What You Will Find in the Following

More information

AUXILIARY POWER SUPPLIES IN LOW POWER INVERTERS FOR THREE PHASE TESLA S INDUCTION MOTORS

AUXILIARY POWER SUPPLIES IN LOW POWER INVERTERS FOR THREE PHASE TESLA S INDUCTION MOTORS AUXILIARY POWER SUPPLIES IN LOW POWER INVERTERS FOR THREE PHASE TESLA S INDUCTION MOTORS Petar J. Grbovic Schneider Toshiba Inverter Europe, R&D 33 Rue Andre Blanchet, 71 Pacy-Sur-Eure, France petar.grbovic@fr.schneiderelectric.com

More information

Soft-Switching Two-Switch Resonant Ac-Dc Converter

Soft-Switching Two-Switch Resonant Ac-Dc Converter Soft-Switching Two-Switch Resonant Ac-Dc Converter Aqulin Ouseph 1, Prof. Kiran Boby 2,, Prof. Dinto Mathew 3 1 PG Scholar,Department of Electrical and Electronics Engineering, Mar Athanasius College of

More information

A High Step-Up DC-DC Converter

A High Step-Up DC-DC Converter A High Step-Up DC-DC Converter Krishna V Department of Electrical and Electronics Government Engineering College Thrissur. Kerala Prof. Lalgy Gopy Department of Electrical and Electronics Government Engineering

More information

Power Factor Corrected Single Stage AC-DC Full Bridge Resonant Converter

Power Factor Corrected Single Stage AC-DC Full Bridge Resonant Converter Power Factor Corrected Single Stage AC-DC Full Bridge Resonant Converter Gokul P H Mar Baselios College of Engineering Mar Ivanios Vidya Nagar, Nalanchira C Sojy Rajan Assisstant Professor Mar Baselios

More information

Two-output Class E Isolated dc-dc Converter at 5 MHz Switching Frequency 1 Z. Pavlović, J.A. Oliver, P. Alou, O. Garcia, R.Prieto, J.A.

Two-output Class E Isolated dc-dc Converter at 5 MHz Switching Frequency 1 Z. Pavlović, J.A. Oliver, P. Alou, O. Garcia, R.Prieto, J.A. Two-output Class E Isolated dc-dc Converter at 5 MHz Switching Frequency 1 Z. Pavlović, J.A. Oliver, P. Alou, O. Garcia, R.Prieto, J.A. Cobos Universidad Politécnica de Madrid Centro de Electrónica Industrial

More information

Exclusive Technology Feature. Leakage Inductance (Part 2): Overcoming Power Losses And EMI. Leakage Inductance-Induced Ringing. ISSUE: November 2015

Exclusive Technology Feature. Leakage Inductance (Part 2): Overcoming Power Losses And EMI. Leakage Inductance-Induced Ringing. ISSUE: November 2015 Leakage Inductance (Part 2): Overcoming Power Losses And EMI by Ernie Wittenbreder, Technical Witts, Flagstaff, Ariz ISSUE: November 2015 Part 1 of this article series focused on the science and math of

More information

Single Phase Single Stage Power Factor Correction Converter with Phase Shift PWM Technique

Single Phase Single Stage Power Factor Correction Converter with Phase Shift PWM Technique Single Phase Single Stage Power Factor Correction Converter with Phase Shift PWM Technique G.KAVIARASAN 1, M.G ANAND 2 1 PG Scholar, Department of Power Electronics and Drives THE KAVERY ENGINEERNG COLLEGE,salem

More information

An Interleaved Flyback Inverter for Residential Photovoltaic Applications

An Interleaved Flyback Inverter for Residential Photovoltaic Applications An Interleaved Flyback Inverter for Residential Photovoltaic Applications Bunyamin Tamyurek and Bilgehan Kirimer ESKISEHIR OSMANGAZI UNIVERSITY Electrical and Electronics Engineering Department Eskisehir,

More information

Linear Peak Current Mode Controlled Non-inverting Buck-Boost Power-Factor-Correction Converter

Linear Peak Current Mode Controlled Non-inverting Buck-Boost Power-Factor-Correction Converter Linear Peak Current Mode Controlled Non-inverting Buck-Boost Power-Factor-Correction Converter Mr.S.Naganjaneyulu M-Tech Student Scholar Department of Electrical & Electronics Engineering, VRS&YRN College

More information

A Color LED Driver Implemented by the Active Clamp Forward Converter

A Color LED Driver Implemented by the Active Clamp Forward Converter A Color LED Driver Implemented by the Active Clamp Forward Converter C. H. Chang, H. L. Cheng, C. A. Cheng, E. C. Chang * Power Electronics Laboratory, Department of Electrical Engineering I-Shou University,

More information

Performance Improvement of Bridgeless Cuk Converter Using Hysteresis Controller

Performance Improvement of Bridgeless Cuk Converter Using Hysteresis Controller International Journal of Electrical Engineering. ISSN 0974-2158 Volume 6, Number 1 (2013), pp. 1-10 International Research Publication House http://www.irphouse.com Performance Improvement of Bridgeless

More information

IT is well known that the boost converter topology is highly

IT is well known that the boost converter topology is highly 320 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 21, NO. 2, MARCH 2006 Analysis and Design of a Low-Stress Buck-Boost Converter in Universal-Input PFC Applications Jingquan Chen, Member, IEEE, Dragan Maksimović,

More information

Power Factor Correction of LED Drivers with Third Port Energy Storage

Power Factor Correction of LED Drivers with Third Port Energy Storage Power Factor Correction of LED Drivers with Third Port Energy Storage Saeed Anwar Mohamed O. Badawy Yilmaz Sozer sa98@zips.uakron.edu mob4@zips.uakron.edu ys@uakron.edu Electrical and Computer Engineering

More information

Chapter 6 Soft-Switching dc-dc Converters Outlines

Chapter 6 Soft-Switching dc-dc Converters Outlines Chapter 6 Soft-Switching dc-dc Converters Outlines Classification of soft-switching resonant converters Advantages and disadvantages of ZCS and ZVS Zero-current switching topologies The resonant switch

More information

BIDIRECTIONAL dc dc converters are widely used in

BIDIRECTIONAL dc dc converters are widely used in 816 IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II: EXPRESS BRIEFS, VOL. 62, NO. 8, AUGUST 2015 High-Gain Zero-Voltage Switching Bidirectional Converter With a Reduced Number of Switches Muhammad Aamir,

More information

Improved Battery Charger Circuit Utilizing Reduced DC-link Capacitors

Improved Battery Charger Circuit Utilizing Reduced DC-link Capacitors Improved Battery Charger Circuit Utilizing Reduced DC-link Capacitors Vencislav Valchev 1, Plamen Yankov 1, Orlin Stanchev 1 1 Department of Electronics and Microelectronics, Technical University of Varna,

More information

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function 328 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 50, NO. 2, APRIL 2003 A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function Sangsun Kim, Member, IEEE, and Prasad

More information

AN IMPROVED ZERO-VOLTAGE-TRANSITION INTERLEAVED BOOST CONVERTER WITH HIGH POWER FACTOR

AN IMPROVED ZERO-VOLTAGE-TRANSITION INTERLEAVED BOOST CONVERTER WITH HIGH POWER FACTOR AN IMPROVED ZERO-VOLTAGE-TRANSITION INTERLEAVED BOOST CONVERTER WITH HIGH POWER FACTOR Naci GENC 1, Ires ISKENDER 1 1 Gazi University, Faculty of Engineering and Architecture, Department of Electrical

More information

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS - HIGH VOLTAGE BOOST-HALF- BRIDGE (BHB) CELLS USING THREE PHASE DC-DC POWER CONVERTER FOR HIGH POWER APPLICATIONS WITH REDUCED SWITCH V. Saravanan* & R. Gobu** Excel College of Engineering and Technology,

More information

FOR THE DESIGN of high input voltage isolated dc dc

FOR THE DESIGN of high input voltage isolated dc dc 38 IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 23, NO. 1, JANUARY 2008 Dual Interleaved Active-Clamp Forward With Automatic Charge Balance Regulation for High Input Voltage Application Ting Qian and Brad

More information

Simulation of Soft Switched Pwm Zvs Full Bridge Converter

Simulation of Soft Switched Pwm Zvs Full Bridge Converter Simulation of Soft Switched Pwm Zvs Full Bridge Converter Deepak Kumar Nayak and S.Rama Reddy Abstract This paper deals with the analysis and simulation of soft switched PWM ZVS full bridge DC to DC converter.

More information

Design And Analysis Of Dc-Dc Converter For Photovoltaic (PV) Applications.

Design And Analysis Of Dc-Dc Converter For Photovoltaic (PV) Applications. IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 PP 53-60 www.iosrjen.org Design And Analysis Of Dc-Dc Converter For Photovoltaic (PV) Applications. Sangeetha U G 1 (PG Scholar,

More information

CURRENT-FED dc dc converters have recently seen resurgence

CURRENT-FED dc dc converters have recently seen resurgence IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 22, NO. 2, MARCH 2007 461 Current-Fed Dual-Bridge DC DC Converter Wei Song, Member, IEEE, and Brad Lehman, Member, IEEE Abstract A new isolated current-fed

More information

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application Vol.3, Issue.1, Jan-Feb. 2013 pp-530-537 ISSN: 2249-6645 Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application B.D.S Prasad, 1 Dr. M Siva Kumar 2 1 EEE, Gudlavalleru Engineering

More information

HALF BRIDGE CONVERTER WITH WIDE RANGE ZVS

HALF BRIDGE CONVERTER WITH WIDE RANGE ZVS INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & Proceedings of the International Conference on Emerging Trends in Engineering and Management (ICETEM14) TECHNOLOGY (IJEET) ISSN 0976 6545(Print) ISSN 0976

More information

Voltage Fed DC-DC Converters with Voltage Doubler

Voltage Fed DC-DC Converters with Voltage Doubler Chapter 3 Voltage Fed DC-DC Converters with Voltage Doubler 3.1 INTRODUCTION The primary objective of the research pursuit is to propose and implement a suitable topology for fuel cell application. The

More information

CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS

CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS 68 CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS 4.1 INTRODUCTION The main objective of this research work is to implement and compare four control methods, i.e., PWM

More information

GENERALLY, at higher power levels, the continuousconduction-mode

GENERALLY, at higher power levels, the continuousconduction-mode 496 IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 35, NO. 2, MARCH/APRIL 1999 A New, Soft-Switched Boost Converter with Isolated Active Snubber Milan M. Jovanović, Senior Member, IEEE, and Yungtaek

More information

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter 3.1 Introduction DC/DC Converter efficiently converts unregulated DC voltage to a regulated DC voltage with better efficiency and high power density.

More information

Comparison and Simulation of Full Bridge and LCL-T Buck DC-DC Converter Systems

Comparison and Simulation of Full Bridge and LCL-T Buck DC-DC Converter Systems Comparison and Simulation of Full Bridge and LCL-T Buck DC-DC Converter Systems A Mallikarjuna Prasad 1, B Gururaj 2 & S Sivanagaraju 3 1&2 SJCET, Yemmiganur, Kurnool, India 3 JNTU Kakinada, Kakinada,

More information

BIDIRECTIONAL CURRENT-FED FLYBACK-PUSH-PULL DC-DC CONVERTER

BIDIRECTIONAL CURRENT-FED FLYBACK-PUSH-PULL DC-DC CONVERTER BIDIRECTIONAL CURRENT-FED FLYBACK-PUSH-PULL DC-DC CONVERTER Eduardo Valmir de Souza and Ivo Barbi Power Electronics Institute - INEP Federal University of Santa Catarina - UFSC www.inep.ufsc.br eduardovs@inep.ufsc.br,

More information

Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application

Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application Thomas Mathew.T PG Student, St. Joseph s College of Engineering, C.Naresh, M.E.(P.hd) Associate Professor, St.

More information

ZVT Buck Converter with Synchronous Rectifier

ZVT Buck Converter with Synchronous Rectifier IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 8 February 217 ISSN (online): 2349-784X ZVT Buck Converter with Synchronous Rectifier Preenu Paul Assistant Professor Department

More information

IN high-voltage/low-current applications, such as TV-

IN high-voltage/low-current applications, such as TV- IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 14, NO. 1, JANUARY 1999 177 A Three-Switch High-Voltage Converter Dongyan Zhou, Member, IEEE, Andzrej Pietkiewicz, and Slobodan Ćuk, Fellow, IEEE Abstract A

More information

Soft Switched Resonant Converters with Unsymmetrical Control

Soft Switched Resonant Converters with Unsymmetrical Control IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 10, Issue 1 Ver. I (Jan Feb. 2015), PP 66-71 www.iosrjournals.org Soft Switched Resonant Converters

More information

In addition to the power circuit a commercial power supply will require:

In addition to the power circuit a commercial power supply will require: Power Supply Auxiliary Circuits In addition to the power circuit a commercial power supply will require: -Voltage feedback circuits to feed a signal back to the error amplifier which is proportional to

More information

Experimental study of snubber circuit design for SiC power MOSFET devices

Experimental study of snubber circuit design for SiC power MOSFET devices Computer Applications in Electrical Engineering Vol. 13 2015 Experimental study of snubber circuit design for SiC power MOSFET devices Łukasz J. Niewiara, Michał Skiwski, Tomasz Tarczewski Nicolaus Copernicus

More information

The First Step to Success Selecting the Optimal Topology Brian King

The First Step to Success Selecting the Optimal Topology Brian King The First Step to Success Selecting the Optimal Topology Brian King 1 What will I get out of this session? Purpose: Inside the Box: General Characteristics of Common Topologies Outside the Box: Unique

More information

A HIGHLY EFFICIENT ISOLATED DC-DC BOOST CONVERTER

A HIGHLY EFFICIENT ISOLATED DC-DC BOOST CONVERTER A HIGHLY EFFICIENT ISOLATED DC-DC BOOST CONVERTER 1 Aravind Murali, 2 Mr.Benny.K.K, 3 Mrs.Priya.S.P 1 PG Scholar, 2 Associate Professor, 3 Assistant Professor Abstract - This paper proposes a highly efficient

More information

THREE-PHASE converters are used to handle large powers

THREE-PHASE converters are used to handle large powers IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 14, NO. 6, NOVEMBER 1999 1149 Resonant-Boost-Input Three-Phase Power Factor Corrector Da Feng Weng, Member, IEEE and S. Yuvarajan, Senior Member, IEEE Abstract

More information

Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications

Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications Karthik Sitapati Professor, EEE department Dayananda Sagar college of Engineering Bangalore, India Kirthi.C.S

More information