Ideal for testing taping machines and sorters C METER C HiTESTER / / Electronic measuring instruments

Size: px
Start display at page:

Download "Ideal for testing taping machines and sorters C METER C HiTESTER / / Electronic measuring instruments"

Transcription

1 METER HiTESTER /504-50/ Electronic measuring instruments For Low apacitance METER Measures at 1 khz and 1 MHz For High apacitance MLs HiTESTERs , and Measures at 120 Hz and 1 khz Ideal for testing taping machines and sorters METER High-speed measurement with an analog measurement time of 0.6 ms (1 MHz) Improved noise resistance and dramatically increased repeatability for measurement of minuscule capacitance values Stable measurement of low-capacitance capacitors at 1 MHz HiTESTER /504-50/ onstant-voltage measurement with an analog measurement time of 1 ms (1 khz); ideal for measurement of high-capacitance MLs onstant-voltage measurement of high capacitance values up to 1.45 mf (120 Hz, 500 mv) Model provides four-terminal contact checking.

2 2 METER Analog measurement times as low as 0.6 ms for improved capacitor productivity ommon Features of Models , , and n -Meter measurement frequencies comply with JIS apacitor Type Range 1000 pf Non-Electrolytic 1000 pf < 10 µf 10 µf < Electrolytic - Measurement Frequency [Hz] Supporting Indicates recommended frequency 1k M Models (for ref.) n BIN function measurement values can be classified into up to 14 *1 ranks for easy sorting. *1 Models support up to 1 ranks. n omparator function Upper and lower limits can be specified for first () and second () parameters. Evaluation results can be indicated by beeper, LE indicators and external output, with the setting values always displayed. n Memory function Measurement data is stored in the instrument and can be downloaded via GP-IB or RS ,000 measurements , and ,000 measurements n Intuitive operation with LE indicators Simply select the desired operation on the front panel. The current measurement configuration settings are indicated by LEs so you can check your settings at a glance. n Trigger-synchronous output The measurement signal is applied to the test sample only when a measurement trigger is applied. Because large current does not flow when making and breaking contact with the sample, contact point wear is minimized. n Stores 99 *2 measurement configurations Store up to 99 sets of measurement configuration settings for quick recall when switching test sample types on lines with many repeating measurements. Any measurement configuration can be recalled by EXT I/O. *2 Models store up to 70 measurement configurations. n ontact-checking functions included etect contact errors during measurement. Improve yield rates by separately managing samples that exhibit contact errors.

3 n High-speed measurements as fast as 1.5 ms (0.6 ms for analog measurements) High-speed testing such as with taping machines is supported by the 1.5 ms minimum measurement time (at FAST, 1 MHz measurements, ). Select from FAST, NORMAL and SLOW measurement speeds Measurement Frequency 1kHz 1MHz Measurement Speed Output Signal FAST NORMAL SLOW INEX 1.1ms 4.1ms 1.ms EOM 2ms 5ms 14ms INEX 0.6ms 4.1ms 1.ms EOM 1.5ms 5ms 14ms , , Measurement Frequency 120 Hz 1 khz Measurement Speed Output Signal FAST NORMAL SLOW INEX 8. ms. ms 1. ms EOM 10 ms 7.5 ms 146 ms INEX 1 ms 4 ms 24 ms EOM 2 ms 5.5 ms 29.5 ms Easy integration into automatic testing equipment EXT I/O RS-22 GP-IB Voltage selector EXT I/O Voltage selector GP-IB * RS-22 * Model does not include a GP-IB interface. METER HiTESTER , , n EXT I/O Triggering and loading of measurement conditions can be controlled externally. apable of external output of comparator results, BIN measurement results, and end-ofmeasurement signals, these meters support full interfacing with automated devices. n EXT I/O Timing hart TRIG 1 huck 1 End-of-Measurement 2 Transport 2 huck Inputs External power input (+5 to 24 V, may be supplied from external device) External trigger signal Panel number (Measurement configuration) selection Panel-number-valid signal alibration EXT I/O Features Outputs Internal power output (+5 V) omparator result output (first and second parameters, and ANed results) Bin measurement judgment output Analog End-of-Measurement signal End-of-Measurement signal Error message output INEX EOM HI, IN, LO, BIN 0 Judgment 0.6 ms* 1 Analog Measurement 1.5 ms* 1 Measuring 1 Analog End-of-Measurement 1 End-of-Measurement 1 Judgment * Measurement Speed: FAST used for example. Applicable for 1 MHz measurements. n RS-22 and GP-IB interface *4 Except for turning the instrument's power on and off, all meter functions can be controlled from a computer. This facilitates efficient data handling when controlling or processing data in batches on a computer or when setting instrument processing or measurement conditions. *4 GP-IB is available on Model , , RS-22 interface Transfer method: Start-stop transfer ata length: 8 bits Stop bit: 1 bit GP-IB interface Transfer speed: 9600, bps Parity: None elimiter: R+LF, R IEEE common commands (mandatory) can be used onformance standard: IEEE Reference standard: IEEE

4 4 METER Measure low-magnitude capacitors with high accuracy Measurement parameters and frequency ranges Measurement Frequencies Range of Measurements (, ) 120 Hz 1 khz 1 MHz : ff to µf : to N/A Features of Models METER n Faster measurement and improved repeatability ompared to the previous model (506), the delivers higher measurement speeds in FAST mode and an improvement by a factor of approximately 7 in repeatability for measurement of minuscule capacitance values in high-noise environments. These characteristics make the instrument ideal for embedded measurement in taping machines, sorters, and other automatic systems. n Enhanced absolute accuracy A self-calibration function minimizes variations in measurement values due to changes in ambient temperature. In addition, the cable-length-compensation function minimizes measurement errors when the measurement cable is extended from 1 to 2 meters (using 1.5-2V cable). -value repeatability during 1 pf measurement 1.6% 1.4% 1.2% 1.0% 0.8% 0.6% 0.4% 0.2% 0.0% Power supply noise of 0 V Power supply noise of 1,500 V Improvement by a factor of about 7 in repeatability in highnoise environments 0.025% 0.21% 0.016% 1.4% Faster measurement (Analog measurement time, FAST mode) 0.6ms 1.1ms (INEX=0.6ms) 506 (INEX=1.1ms) Repeatability in high-noise environments (1 MHz, 1 V, FAST mode) n Enhanced contact-checking function ontact errors while measuring can be detected by the hatter etection function, Low- Reject function, urrent etection ircuit Monitoring function and the Applied Voltage Value Monitoring function. Yield rates are improved by judging measurement-object contact errors as ERR instead of FAIL. Extremely low capacitance judged as Low (ERR) hatter Faulty ontact hatter hatter etection Function Unstable Voltage and urrent While Measuring ERR Pass / Fail Judgment ontact ondition Normal ontact hatter etection Function Stable Voltage and urrent While Measuring Pass / Fail Judgment hatter Monitoring Interval INEX Analog Measurement Low- Reject Function hatter etection Function

5 5 n Specifications Measured parameters (apacitance), (dissipation factor tan δ), Q (1/tan δ) Measurement frequencies Measurement signal level Range of measurable values 1 khz and 1 MHz Accuracy: ±0.01% or better Frequency shift: 1 MHz ±1%, ±2% Open-circuit terminal voltage: 500 mv or 1 V Signal level accuracy: ±10% ±5 mv Output resistance: Approx. 1Ω (@1 khz in 2.2 μf and higher ranges), approx. 20 Ω (in ranges other than the above) : ff to μf : to Q: 0.0 to Equivalent circuit mode Series-Parallel Equivalent ircuit mode (Auto/Manual) Representative value: 1.5 ms (FAST) Measurement time (Actual measurement time depends on measurement configuration settings) Measurement speed FAST, NORMAL and SLOW Averaging function 1 to 256 Low- reject function Bad ontact etection (open circuit between terminals) hatter detection function Bad ontact etection (chatter) urrent detection circuit monitoring function Applied voltage value monitoring function Trigger function Trigger delay Memory function A measurement signal fault is detected when external noise causes measurement levels to be out of tolerance for the measurement range. An error is detected when voltage monitored across a test sample is outside of the judgment standard. Internal and external triggers can be enabled 0 to s Up to 1,000 measurement values can be stored in the instrument (ownloadable by GP-IB and RS-22) ompensation Trigger-synchronous output function Key-lock function BIN measurement omparator Panel save and load Audible beeper Interface Printer function isplay device Operating temperature and humidity Storage temperature and humidity METER Open- and short-circuit compensation, load and cable length compensation, and self calibration Functions to inhibit measurement voltage except while actually measuring Settings can be made and cancelled by front panel keys : 1 ranks, -NG, OUT OF BINS, Absolute value setting, setting, % setting : HI, IN, LO; (Q): HI, IN, LO Absolute value setting, setting, % setting 70 setting configurations can be stored Load method: key operation or external I/O Setting the buzzer for comparator judgment results (IN or NG) to ON or OFF is possible RS-22, GP-IB and EXT I/O (included as standard) Measurement values can be printed (requires Model 9442 or 9444 cable) LEs (on/off) 0 to 40, 80% rh or less (non-condensating) -10 to 55, 80% rh or less (non-condensating) Operating environment Indoors, to 2000 m ASL Power supply Selectable 100, 120, 220 or 240 V ±10%, 50/60 Hz Max. power consumption 40 VA Withstand voltage Power line to ground: 1.9 kv A for 15 s Backup battery life Approx. 6 years imensions Approx. 260 W 100 H 298 mm (10.24" W.94" H 11.7" ) (exc. projections) Mass Approx. 4.8 kg (169. oz) Applicable standards EM: EN6126, EN , EN Safety: EN Supplied accessories Power ord, Spare Fuse Measurement accuracy and range Temp. and humidity for guaranteed accuracy: 2 ±5%, 80% rh or less (non-condensating) Warm-up time: 1 h, with open- and short-circuit compensation, and self calibration set to Auto n Measurement area : ff to μf; : to n Measurement accuracy n Basic accuracy [Guaranteed accuracy: 6 months when 0.1] Use the following equation to calculate the measurement accuracy. Measurement accuracy = basic accuracy B E [B: Measurement signal level coefficient] 1 V: 1, 500 mv: 2 [: Measurement speed coefficient] FAST: 1.5 (1kHz), (1MHz) NORMAL: 1.2, SLOW: 1 [: able length coefficient] (using 1.5-2V cable) 0 m: 1, 1 m: 1.5, 2 m: 2 [E: Temperature coefficient] t-2 t = operating temperature ( ) range Parameter 100 pf 220 pf 470 pf 1 nf 2.2 nf 4.7 nf 10 nf 22 nf 47 nf 100 nf 220 nf 470 nf 1 μf 2.2 μf 4.7 μf 10 μf Accuracy 1 khz 0.12%rdg+0.2%rdg (r/x) (r/x) 0.12%rdg+0.08%rdg (r/x) (r/x) 0.12%rdg+0.04%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) range Parameter 220 ff 470 ff 1 pf 2.2 pf 4.7 pf 10 pf 22 pf 47 pf 100 pf 220 pf 470 pf 1 nf Accuracy 1 MHz 0.2%rdg+1%rdg (r/x) (r/x) 0.15%rdg+0.%rdg (r/x) (r/x) 0.12%rdg+0.16%rdg (r/x) (r/x) 0.12%rdg+0.08%rdg (r/x) (r/x) 0.12%rdg+0.04%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) 0.12%rdg+0.02%rdg (r/x) (r/x) [x : the electrical capacity of the sample / r : the electrical capacity of the measurement range]

6 6 HiTESTER , and Perform high-speed, constant-voltage testing even of high-capacitance MLs Measurement parameters and frequency ranges Measurement Frequencies Range of Measurements (, ) 120 Hz 1 khz 1 MHz : pf to mf : to N/A Functional differences between Models , and onstant-voltage Four-Terminal Measurement (V) Bin Interface ontact heck Function 100mV 500mV 1V Function RS-22 GP-IB EXT I/O N/A N/A N/A N/A N/A N/A Features of Model , and HiTESTERs n onstant voltage measurement (V) onstant measuring voltages of 1 V, 500 mv and 100 mv *1 are provided for voltage-dependent capacitance measurements. Measurement frequency is selectable from 120 Hz or 1 khz. *1 100 mv in Model only. n ompatible with taping machine assemblies Model provides the speed and good cost-performance suitable for taping machine systems. n Specifications Measured parameters (capacitance), (dissipation factor tan δ) Measurement frequencies Measurement signal level *1 100 mv in Model only Range of measurable values 120 Hz or 1 khz Accuracy: ±0.01% or better (1) onstant voltage mode: 100 mv *1, 500 mv and 1 V V 1V measurement ranges: up to 70 μf range (1 khz) up to 0.7 mf range (120 Hz) V100 mv *1, V 500 mv measurement ranges: up to 170 μf range (1 khz) up to 1.45 mf range (120 Hz) Signal level accuracy: ±10% ±5 mv (2) Open terminal voltage mode: 100 mv *1, 500 mv and 1 V Measurement range: Other than the above Output resistance: approx. 5Ω Signal level accuracy: ±10% ±5 mv : pf to mf : to Equivalent circuit mode Series/parallel equivalent-circuit mode (Auto/Manual) Nominal 2 ms (1 khz, FAST) Measurement time (The measurement time differs depending on the measurement frequency and measurement speed that are set.) Measurement speed FAST / NORMAL / SLOW Trigger function Internal and external trigger sources can be selected. Trigger delay 0 to s (at s resolution) ompensation Open, Short, Load and Offset compensation, Self-calibrating Averaging function 1 to 256 Four-terminal contact-checking function* (* only) etects contact anomalies (open state in four-terminal measurements) etects contact anomalies (open state in two-terminal Low- reject function measurements) hatter detection function etects contact bounce (chatter) n Four-Terminal ontact-hecking Function The features a 4-terminal contact checking mechanism. etection of contact errors involving all four terminals, including the POT terminal, ensures improved measured value reliability. n Enhanced ontact-hecking Functions ontact errors can be detected while measuring by the Low- Reject and hatter etection functions. Yield rates are improved by judging measurement object contact errors as ERR instead of FAIL. Trigger-synchronous output function Key-lock function BIN measurement (Not available on the ) Function to apply a measurement signal only when performing measurement. The key lock can be set and cancelled by key operation on the front panel ; 14 ranks, -NG, OUT OF BINS Absolute value setting, Δ% setting Memory function Up to 2,000 measurement values can be stored in the instrument (ownloadable by GP-IB and RS-22) omparator : HI / IN / LO, : HI / IN / LO Absolute value setting, Δ% setting Panel save and load Up to 99 sets of measurement conditions can be saved. Load method: Key operation, external I/O. Audible beeper The beeper can be set on or off according to the comparator evaluation result ( IN or NG ) and Bin decision result. Interface Models , : RS-22, GP-IB, EXT I/O (standard) Model : RS-22, EXT I/O (standard) Printer function Measurement values can be printed (requires Printer 9442 and optional onnection able 9444) isplay device LE Operating temperature and humidity 0 to 40, 80% rh or less (no condensation) Storage temperature and humidity -10 to 55, 80% rh or less (no condensation) Operating environment Indoors, up to 2000 m ASL Power supply A 100 V, 120 V, 220 V, or 240 V±10% (selectable), 50/60 Hz Max. power consumption 110 VA max. Withstand voltage Power line to ground, A 1.69 kv, 15 sec. Backup battery life Approx. 6 years imensions Approx. 260 (W) 100 (H) 220 () mm (10.24 W.94 H 8.66 ) (excluding protrusions) Mass Approx..8 kg (14.0 oz) Applicable standards EM: EN6126, EN , EN Safety: EN Supplied accessories Power cord, spare fuse

7 7 HiTESTER , and Measurement accuracy and range Temp. and humidity for guaranteed accuracy: 2 ±5%, 80% rh or less (non-condensating) Warm-up time: 1 h, with open- and short-circuit compensation n Measurement area : pf to mf; : to n Measurement accuracy Use the following equation to calculate the measurement accuracy. Measurement accuracy = basic accuracy B E [B: Measurement signal level coefficient] 1 V and 500 mv: 1, 100 mv: 1.5 [: Measurement speed coefficient] FAST: 1.5 NORMAL: 1.0 (at 1 khz, 1 V), 1.2 (except at 1 khz, 1 V) SLOW: 1 [: able length coefficient] (using 1.5-2V cable) 0 m: 1 1 m: 1 (at 1 khz, 1 V) 1.5 (except at 1 khz, 1 V) [E: Temperature coefficient] t-2 t = operating temperature ( ) n Basic accuracy [Guaranteed accuracy: 6 months when 0.1] Range No. range Basic accuracy *2 V 120 Hz 1 khz Parameter 120 Hz 1 khz operation ±0.20%rdg.±00dgt. ±0.20%rdg.±00dgt. ±0.0120±2/L ±0.0120±0.25/L ±0.20%rdg.±60dgt. ±0.20%rdg.±60dgt. ±0.0020±2.2/L ±0.0020±0.265/L ±0.16%rdg.±20dgt. ±0.14%rdg.±20dgt. ±0.006 ±0.006 ±0.15%rdg.±15dgt. ±0.1%rdg.±15dgt. ± ± ±0.15%rdg.±15dgt. ±0.1%rdg.±15dgt. ± ± ±0.15%rdg.±15dgt. ±0.09%rdg.±10dgt. ± ± ±0.25%rdg.±20dgt. ±0.1%rdg.±15dgt. ±0.005 ± pf 20 pf 2 2 nf 200 pf 20 nf 2 nf nf 20 nf 5 2 μf 200 nf 6 20 μf 2 μf μf 20 μf mf(1v) 70 μf(1v) ±1.2%rdg.±50dgt. ±0.7%rdg.±40dgt mf(500 mv, 100 mv) 170 μf(500 mv, 100 mv) ± ± mf 200 μf ±1.2%rdg.±50dgt. ±0.7%rdg.±40dgt. ± ± mf 2 mf ±2.5%rdg.±50dgt. ±2.0%rdg.±40dgt. ±0.0200±0.008 H ±0.0180±0.08 H [L: apacitance of component (pf), H: apacitance of component (mf)] *2 Accuracy of range nos. 1 and 2 are not guaranteed at 100 mv measurement signal level. N/A N/A LR meter for production lines and automated testing LR METER IM52 ± 0.05% accuracy with wide measurement range (R testing, 40Hz to 200kHz, 5mV to 5V, 10uA to 50mA) Non-stop testing over mixed measurement conditions such as - and ESR at 10 times the speed of previous models (compare with the model ) Built-in comparator and BIN functions Rapid 2ms test time This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. All probes are constructed with a 1.5-2V coaxial cable. For an RS-22 connection: A crossover cable for interconnection can be used. You can use the RS-22 ABLE 967 without hardware flow control. Single evice Solution for High Speed Testing and Frequency Sweeping IMPEANE ANALYZER IM570 Special Model with 100 mv Measurement Signal METER mv special model LR measurement, R measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument High-speed testing, achieving maximum speeds of 1.5ms (1 khz) and 0.5ms (100kHz) in LR mode High-accuracy measurements, basic accuracy of Z parameter: ± 0.08% This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. For an RS-22 connection: A crossover cable for interconnection can be used. You can use the RS-22 ABLE 967 without hardware flow control. 100 mv measurement signal level (500 mv measurement signal level not available) Ideal for use in applications requiring a low measurement signal level, for example diode junction capacitance measurement ontact your HIOKI distributor for more information about this special model.

8 8 Model onfigurations and Options Probes and Test Fixtures for TERMINAL PROBE L TERMINAL PROBE PINHER PROBE TEST FIXTURE able length 1 m (.28 ft), to 5 MHz, impedance 4 electrode terminals, measurable conductor diameter: ø0. mm (0.01 in) to 5 mm (0.20 in) able length 1 m (.28 ft), to 200 khz, impedance 4 electrode terminals, measurable conductor diameter: ø0. mm (0.01 in) to 5 mm (0.20 in) able length 1 m (.28 ft), to 5 MHz, impedance 2 electrode terminals, tip electrode spacing: 0. (0.01 in) to 6 mm (0.24 in) able length 1 m (.28 ft), to 5 MHz, impedance 4 electrode terminals, measurable conductor diameter: ø0. mm (0.01 in) to 1.5 mm (0.06 in) Probes and Test Fixtures for /504-50/ TERMINAL PROBE 9140 able length 1 m (.28 ft), to 100 khz, impedance characteristics of 75 Ω, 5-terminal configuration, 4 electrode terminals, measurable conductor diameter: ø0. mm (0.01 in) to 5 mm (0.20 in) PINHER PROBE 914 able length 1 m (.28 ft), to 5 MHz, impedance characteristics of 75 Ω, 4-terminal pair configuration, 2 electrode terminals, tip electrode spacing: 0. (0.01 in) to 6 mm (0.24 in) TEST FIXTURE 9261 able length 1 m (.28 ft), to 5 MHz, impedance characteristics of 75 Ω, 4-terminal configuration, 4 electrode terminals, measurable conductor diameter: ø0. mm (0.01 in) to 1.5 mm (0.06 in) 4-TERMINAL PROBE able length 1 m (.28 ft), to 200 khz, impedance 4 electrode terminals, measurable conductor diameter: ø0. mm (0.01 in) to 2 mm (0.08 in) Probes and Test Fixtures for / /504-50/ TEST FIXTURE 9262 SM TEST FIXTURE 926 SM TEST FIXTURE 9677 SM TEST FIXTURE 9699 irect connection type, to 5 MHz, 2 electrode terminals, measurable conductor diameter: ø0. mm (0.01 in) to 2 mm (0.08 in) irect connection type, to 5 MHz, 2 electrode terminals, test sample dimensions:1 mm (0.04 in) to 10 mm (0.9 in) irect connection type, Electrodes on side for SM, to 120 MHz, 2 electrode terminals, test sample dimensions:.5 mm ±0.5 mm (0.14 in ±0.02 in) irect connection type, Electrodes on bottom for SM, to 120 MHz, 2 electrode terminals, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, maximum 1.5 mm (0.06 in) high For Low-Magnitude apacitors METER (Measurement frequencies: 1 khz and 1 MHz) For High-Magnitude ML HiTESTER (Measurement frequencies: 120 Hz and 1 khz, four-terminal contact-checking function, constant voltage measurement at 100 mv, 500 mv and 1 V) HiTESTER (Measurement frequencies: 120 Hz and 1 khz constant voltage measurement at 500 mv and 1 V) HiTESTER (Measurement frequencies: 120 Hz and 1 khz constant voltage measurement at 500 mv and 1 V, no GP-IB interface, no Bin function) Probe and test fixtures are not supplied with the unit. Select an optional probe and test fixture when ordering. Printer PRINTER 9442 (The optional onnection able 9444 and A Adapter are required to connect the Printer 9442.) Measurement values, comparator results, and BIN measurement results can be printed out on the optional Printer 9442 via the standard RS-22 interface. onvenient for applications that require printed data to be attached to inspection results. n Printer 9442 specifications Printing method: Thermal serial dot printer Paper width: 112 mm Print speed: 52.5 cps Power supply: A Adapter 944 or supplied NiMH battery (prints 000 lines after full charge using 944) imensions and weight: Approx. 160W 66.5H 170 mm (6.0 W 2.62 H 6.69 ), 580 g (20.5 oz) A AAPTER (for 9442, Japan) ONNETION ABLE 9444 (for 9442) Interface able A AAPTER (for 9442, EU) REORING PAPER 1196 (for 9442, 25 m ( ), 10 rolls) GP-IB ONNETOR ABLE m (6.56 ft) Note: ompany names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. HIOKI (Shanghai) SALES & TRAING O., LT.: TEL FAX / info@hioki.com.cn ISTRIBUTE BY HEAQUARTERS: 81 Koizumi, Ueda, Nagano, , Japan TEL FAX / os-com@hioki.co.jp HIOKI USA ORPORATION: TEL FAX / hioki@hiokiusa.com HIOKI INIA PRIVATE LIMITE: TEL FAX hioki@hioki.in HIOKI SINGAPORE PTE. LT.: TEL FAX info@hioki.com.sg HIOKI KOREA O., LT.: TEL FAX info-kr@hioki.co.jp All information correct as of Aug. 29, 201. All specifications are subject to change without notice E1-8E-02N Printed in Japan

Ideal for testing taping machines and sorters. C METER C HiTESTER 3504

Ideal for testing taping machines and sorters. C METER C HiTESTER 3504 METER 506-10 HiTESTER 504 For Low apacitance METER 506-10 Measures at 1 khz and 1 MHz For High apacitance MLs HiTESTERs 504-60, 504-50 and 504-40 Measures at 120 Hz and 1 khz Ideal for testing taping machines

More information

Ideal for testing taping machines and sorters

Ideal for testing taping machines and sorters METER 506-10 HiTESTER 504 For Low apacitance METER 506-10 Measures at 1 khz and 1 MHz For High apacitance MLs HiTESTERs 504-60, 504-50 and 504-40 Measures at 120 Hz and 1 khz Ideal for testing taping machines

More information

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development LCR METER Series Component measuring instruments From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications New LCR METER Models IM3523, IM3533, and IM3533-01

More information

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development LCR METER Series Component measuring instruments From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications New LCR METER Models IM3523, IM3533, and IM3533-01

More information

BATTERY HiTESTER BT3563, BT3562, 3561

BATTERY HiTESTER BT3563, BT3562, 3561 BATTERY HiTESTER BT3563, BT3562, 3561 Simultaneous high-speed measurement of internal resistance and battery voltage From large-cell to high-voltage battery testing - HIOKI is The Choice The BT3563, BT3562,

More information

High-Speed Resistance Meters Optimized for Automated Systems. RESISTANCE HiTESTER RM3542, RM Measure in as little as 0.

High-Speed Resistance Meters Optimized for Automated Systems. RESISTANCE HiTESTER RM3542, RM Measure in as little as 0. RESISTANCE HiTESTER RM3542, RM3542-01 Component measuring instruments Measure in as little as 0.9 ms* High-Speed Resistance Meters Optimized for Automated Systems The RM3542 and RM3542-01 Resistance HiTESTERs

More information

Single Device Solution for High Speed Testing and Frequency Sweeping IMPEDANCE ANALYZER IM3570

Single Device Solution for High Speed Testing and Frequency Sweeping IMPEDANCE ANALYZER IM3570 IMPEDANCE ANALYZER IM3570 Single Device Solution for High Speed Testing and Frequency Sweeping With this new IM3570 Impedance Analyzer, an LCR meter and an impedance analyzer capable of measurement frequencies

More information

IMPEDANCE ANALYZER IM3570

IMPEDANCE ANALYZER IM3570 IMPEDANCE ANALYZER IM3570 Component measuring instruments Single Device Solution for High Speed Testing and Frequency Sweeping With this new IM3570 Impedance Analyzer, an LCR meter and an impedance analyzer

More information

3535 LCR HiTESTER Components measuring instruments

3535 LCR HiTESTER Components measuring instruments 2004 3535 LCR HiTESTER Components measuring instruments HEAD AMP UNIT http//www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available on our

More information

A New Series of LCR Meters to Meet Your Applications

A New Series of LCR Meters to Meet Your Applications Series A New Series of LCR Meters to Meet Your Applications From Production Lines to Research and Development 2 LCR Meter Series Full Product Lineup Model IM3536 IM3533 IM3523 LCR HiTESTER 3511-50 IM3533

More information

CHEMICAL IMPEDANCE ANALYZER IM3590

CHEMICAL IMPEDANCE ANALYZER IM3590 CHEMICAL IMPEDANCE ANALYZER IM3590 Component measuring instruments Ideal for Measuring Electrochemical Impedance Hioki s Chemical Impedance Analyzer IM3590 is designed to perform impedance (LCR) measurement

More information

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool An Energy Saving Support Tool POWER HiTESTER Power Measuring Instruments 3332 STANDBY MODE OFF MODE Single-phase, 2-wire type that can accurately measure even standby power Accurate evaluation of consumption

More information

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520 INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520 3153 3159 Not CE Marked ST5520 This electrical safety test instrument series is designed for insulation resistance and voltage withstand

More information

DIGITAL HiTESTER 3237, 3238, 3239

DIGITAL HiTESTER 3237, 3238, 3239 DIGITAL HiTESTER,, 3239 4-terminal Ω function Advanced model Economically priced 3239 Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed 5 1 /2 digit DMM The DIGITAL

More information

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance BATTERY IMPEDANCE METER BT456 Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance The Ultimate Instrument for Measuring Large-Capacity Li-ion Batteries for EVs 2 Improve

More information

High-precision portable RESISTANCE METER

High-precision portable RESISTANCE METER 8 High-precision portable RESISTANCE METER measures from µω to MΩ Features High-precision specs in a portable package(high accuracy of 0.02% rdg.) Design is ideal for maintenance and testing/measurement

More information

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES 2001 INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES Safety Standards Measuring Instruments 3153 3159 3158 3154 ISO14001 JQA-E-90091 http://www.hioki.co.jp/ HIOKI company overview, new products,

More information

RESISTANCE HiTESTER 3541

RESISTANCE HiTESTER 3541 RESISTANCE HiTESTER 3541 Component measuring instruments 0.1 µω (20 mω range) to 110.000 MΩ Measure from very low (µω) to very high (MΩ) resistances with a single instrument Along with capabilities for

More information

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments.

3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments. 2004 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3

More information

High speed Stability. DC, 4 Hz to 8 MHz. Measurement frequency LCR METER IM3536

High speed Stability. DC, 4 Hz to 8 MHz. Measurement frequency LCR METER IM3536 LCR METER IM3536 DC, 4 Hz to 8 MHz Measurement frequency The new standard Introducing an LCR meter that brings exceptional specifications and cost performance to a wide range of applications, from R&D

More information

High-speed DMM. DIGITAL HiTESTER 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced)

High-speed DMM. DIGITAL HiTESTER 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) DIGITAL HiTESTER 3239 (4-terminal Ω function) 3238 (Advanced model) 3237 (Economically priced) Field measuring instruments Outstanding performance for production lines with a sampling rate of 3.3 ms High-speed

More information

3541 RESISTANCE HiTESTER

3541 RESISTANCE HiTESTER 3541 RESISTANCE HiTESTER Components measuring instruments 0.1 µω (20 mω range) to 110.000 MΩ Measure from very low (µω) to very high (MΩ) resistances with a single instrument Along with capabilities for

More information

INSULATION TESTER SERIES

INSULATION TESTER SERIES INSULATION TESTER SERIES Field measuring instruments A Full Line-up of Insulation Testers to Suit Any Need From Basic Testing to High Performance Analysis 2 INSULATION TESTER SERIES Selection guide IR4056-20

More information

POWER HiTESTER 3331, 3332

POWER HiTESTER 3331, 3332 An Energy Saving Support Tool POWER HiTESTER 3331, 3332 Power measuring instruments 3332: Single-phase, 2-wire type that can accurately measure even standby power 3331: Single-phase, 3-wire and three-phase,

More information

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free

LEAK CURRENT HiTESTER ST5540/ST Washington Street Melrose, MA Phone Toll Free LEAK CURRENT HiTESTER ST5540/ST5541 Safety measuring instruments 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Leak Current Measurement

More information

From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications LCR METER IM3523, IM3533

From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications LCR METER IM3523, IM3533 LCR METER IM52, IM5 From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications LCR METER Models IM52, IM5, and IM5-01 are highly cost-effective testers that

More information

World-Class Accuracy & Measurement Range (40 Conventional Models)

World-Class Accuracy & Measurement Range (40 Conventional Models) AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BATTERY IMPEDANCE METER BT4560 Component measuring instruments Determine Li-ion

More information

Ω and 0.1 fa Current Resolution DIGITAL SUPER MEGOHMMETER DSM-8104, DSM Fast, Highly Accurate Measurement. DSM-8104 (Single-Channel)

Ω and 0.1 fa Current Resolution DIGITAL SUPER MEGOHMMETER DSM-8104, DSM Fast, Highly Accurate Measurement. DSM-8104 (Single-Channel) DIGITAL SUPER MEGOHMMETER, DIGITAL SUPER MEGOHMMETERS (Single-Channel) (Four-Channel) Options Supporting Measurements such as Surface and Volume Resistivity Power Supply Unit Fast, Highly Accurate Measurement

More information

An Evolution in Stable Measurements

An Evolution in Stable Measurements RESISTANCE METER, An Evolution in Stable s Perfect for Taping Machines and Sorting Machines Supports Resistance s for Miniature 008004-size Electronic Parts (0.25 mm 0.125 mm) 99 Washington Street Melrose,

More information

LCR METER IM3523/IM3533/IM

LCR METER IM3523/IM3533/IM LCR METER /IM3533/ Component measuring instruments From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications New LCR METER Models, IM3533, and are highly cost-effective

More information

CATALOG including...

CATALOG including... 2002 CATALOG including... http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available on our website. 1 Advanced Instruments to Meet International

More information

1 Model 3153 Automatic Insulation Voltage Withstand Testing Voltage Control from a PC Full Remote Control All test parameters can be controlled by RS-232C or GP-IB, including test voltage, cut-off current,

More information

AC/DC CLAMP METER CM4371, CM4373

AC/DC CLAMP METER CM4371, CM4373 AC/DC CLAMP METER CM4371, CM4373 Field measuring instruments CM4371 : 600 A AC/DC CM4373 : 2000 A AC/DC Speedy Performance of Professional Testing Made in Japan for rock-solid quality. Rugged clamp meters

More information

Ohmmeter Replacement Guide

Ohmmeter Replacement Guide Ohmmeter Replacement Guide (From 3560 to RM3545) 1. Measurement 2. Functionality 3. External Control (EXT I/O) 4. Commands Please prepare copies of the user manuals for the old and new instruments and

More information

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection. 2004 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER Field measuring instruments Support efficient data collection RS-232C communication All HiTESTERs For Personal

More information

3331, 3332 POWER HiTESTER

3331, 3332 POWER HiTESTER 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com An Energy Saving Support Tool 2002 3331, 3332 POWER HiTESTER Power measuring instruments 3332: Single-phase, 2-wire type that

More information

MEASURING INSTRUMENT. Capacitance Leakage Current / IR Meter Model IR Features.

MEASURING INSTRUMENT. Capacitance Leakage Current / IR Meter Model IR Features. MEASURING INSTRUMENT Capacitance Leakage Current / IR Meter Model IR 2689 Features Capacitance leakage current test function. Insulation resistance test function. Precise low current charge function (0.5mA±0.05mA).

More information

CATALOGO STRUMENTI Ricerca & Sviluppo

CATALOGO STRUMENTI Ricerca & Sviluppo CATALOGO STRUMENTI Ricerca & Sviluppo MISURE PRIMARIE PONTI LCR TECNOLOGIA INDICE MISURE PRIMARIE Ponti LCR...p 3 3511/50...p 3 IM3536...p 7 IM3523 IM3533...p 23 IM3570...p 39 STRUMENTI R&S MISURE PRIMARIE

More information

AC/DC CLAMP METER CM4370 series

AC/DC CLAMP METER CM4370 series AC/DC CLAMP METER CM4370 series CM4371, CM4372 : 600 A AC/DC CM4373, CM4374 : 2000 A AC/DC Speedy Performance of Professional Testing Made in Japan for rock-solid quality. Rugged clamp meters for the toughest

More information

PRECISION DC VOLTMETER DM7275, DM ½ Digit. Precision DC Voltmeter. 9 ppm DC Voltmeter for R&D to Production Lines

PRECISION DC VOLTMETER DM7275, DM ½ Digit. Precision DC Voltmeter. 9 ppm DC Voltmeter for R&D to Production Lines PRECISION DC VOLTMETER DM7275, DM7276 7½ Digit Precision DC Voltmeter 9 ppm DC Voltmeter for R&D to Production Lines 2 High-Accuracy Measurement Approaching the Precision of Reference Instruments Outstanding

More information

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI

More information

Featuring super-high accuracy and multi-channel capabilities (20 channels with 4-terminal measurement)

Featuring super-high accuracy and multi-channel capabilities (20 channels with 4-terminal measurement) RESISTANCE METER / Component measuring instruments RESISTANCE METER Featuring super-high accuracy and multi-channel capabilities (20 channels with 4-terminal measurement) Basic accuracy : 0.006% No. of

More information

Standard models. Introducing a line of field-optimized instruments that can be chosen based on the application at hand

Standard models. Introducing a line of field-optimized instruments that can be chosen based on the application at hand Featuring the world s fastest DMM engine* The DT4200 series features a dedicated IC that Hioki developed in-house in order to deliver unprecedented speed. *According to Hioki research conducted in April

More information

AC/DC CLAMP METER CM4370 series

AC/DC CLAMP METER CM4370 series AC/DC CLAMP METER CM4370 series CM4371, CM4372 : 600 A AC/DC CM4373, CM4374 : 2000 A AC/DC Speedy Performance of Professional Testing Made in Japan for rock-solid quality. Rugged clamp meters for the toughest

More information

High-accuracy bench-top meter ideal for production lines RESISTANCE METER RM3545, RM3544

High-accuracy bench-top meter ideal for production lines RESISTANCE METER RM3545, RM3544 RESISTANCE METER, RESISTANCE METER Featuring super-high accuracy and multi-channel capabilities (20 channels with 4-terminal measurement) Basic accuracy : 0.006% No. of display digits: Max. 6.5 Max.resolution

More information

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis

INSULATION TESTER SERIES. Flip the Cover. A Full Line-up of Insulation Testers to Suit Any Need. From Basic Testing to High Performance Analysis INSULATION TESTER SERIES Field measuring instruments A Full Line-up of Insulation Testers to Suit Any Need Flip the Cover From Basic Testing to High Performance Analysis 2 INSULATION TESTER SERIES Selection

More information

Battery Analyzers BA6010 Series

Battery Analyzers BA6010 Series Data Sheet Battery Analyzers RS232 The battery analyzers measure voltage and resistance of modern battery technologies with high accuracy, resolution, and speed. Additionally, these instruments provide

More information

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display 5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP SENSOR Wide-band Models from to 1 MHz CLAMP ON PROBE 3276 1 CLAMP ON PROBE 3273-5 to 3276 Because current measurement requires the insertion of a shunt or a CT, the task often becomes difficult due

More information

DIGITAL / ANALOG HiTESTER SERIES

DIGITAL / ANALOG HiTESTER SERIES DIGITAL / ANALOG HiTESTER SERIES Multi Meters A Full Line-up of Digital and Analog Multimeters Suit Any Need From Basic Testing High Performance Analysis 2 POCKET SIZE DMM SERIES New product information

More information

High-accuracy measurement of standby to operating power

High-accuracy measurement of standby to operating power POWER METER PW3335 Power Measuring Instruments Single-Phase AC/DC Power Meter High- of standby to operating power Wide measurable range : 10 μa to 30 A, 60 mv to 1000 V Basic for voltage, current and power

More information

DIGITAL / ANALOG HiTESTER SERIES

DIGITAL / ANALOG HiTESTER SERIES DIGITAL / ANALOG HiTESTER SERIES Multi Meters A Full Line-up of Digital and Analog Multimeters Suit Any Need From Basic Testing High Performance Analysis 2 A Complete HIOKI Digital Multimeter Line-up Suit

More information

DB230 Capacitor Tester

DB230 Capacitor Tester DB230 Capacitor Tester Quick and accurate testing on automatic production lines THE DB 200 SERIES General The DB230 Component Tester is especially designed for high accuracy testing of capacitors on production

More information

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895 Data Sheet 500 khz / 1 MHz Precision LCR Meter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Industry-Leading Performance The

More information

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895 Data Sheet 500 khz / 1 MHz Precision LCR Meter Industry-Leading Performance The 894 and 895 are high accuracy LCR meters capable of measuring inductance, capacitance, and resistance of components and materials

More information

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM DATA SHEET 34450A Multimeter 5.5 Digit Dual Display, Benchtop DMM Features Fast reading speed of up to 190 readings/sec 0.015% DCV accuracy Multiple connectivity options USB 2.0, Serial Interface (RS-232)

More information

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER Field measuring instruments 2001 Support efficient data collection RS-232C communication All HiTESTERs For Personal

More information

Ohmmeter Replacement Guide

Ohmmeter Replacement Guide Ohmmeter Replacement Guide (From 3227 to RM3545) 1. Measurement 2. Functionality 3. External Control (EXT I/O) 4. Commands Please prepare copies of the user manuals for the old and new instruments and

More information

Ω and 0.1 fa Current Resolution DIGITAL, ULTRA-HIGH RESISTANCE/ ULTRA-LOW CURRENT METERS. Fast, Highly Accurate Measurement DSM-8104, DSM-8542

Ω and 0.1 fa Current Resolution DIGITAL, ULTRA-HIGH RESISTANCE/ ULTRA-LOW CURRENT METERS. Fast, Highly Accurate Measurement DSM-8104, DSM-8542 DIGITAL, ULTRA-HIGH RESISTANCE/ ULTRA-LOW CURRENT METERS, DIGITAL SUPER MEGOHMMETERS Digital, Ultra-High Resistance/ Ultra-Low Current Meters Digital, Ultra-High Resistance/ Ultra-Low Current Meters Power

More information

High-accuracy measurement of standby to operating power

High-accuracy measurement of standby to operating power POWER METER PW3335 Single-Phase AC/DC Power Meter High- of standby to operating power Wide measurable range : 10 μa to 30 A, 60 mv to 1000 V Basic for voltage, current and power : ±0.1%* Frequency bandwidth

More information

Wide-band Models from DC to 100 MHz

Wide-band Models from DC to 100 MHz CLAMP SENSOR Wide-band Models from DC to 1 MHz 3273-5 - 3276 CLAMP ON PROBES http://www.hioki.co.jp/ HIOKI company overview, new products, environmental considerations and other information are available

More information

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides

More information

General Specifications

General Specifications General Specifications Model CA51/ CA71 HANDY CAL calibrator GS 77W02A01-01-E GENERAL The CA51/CA71 HANDY CAL calibrators are comprehensive generating/measuring instruments for all

More information

DC Resistance Meters 2840 Series

DC Resistance Meters 2840 Series Data Sheet DC Meters Touch screen to zoom, select, and enter values The DC resistance meters feature high accuracy and resolution measurements in the milliohm range. Both meters are ideally suited for

More information

Fluke 83V and 87V Digital Multimeters

Fluke 83V and 87V Digital Multimeters Fluke 83V and 87V Digital Multimeters Detailed Specifications For all detailed specifications: is given as ±([% of reading] + [number of least significant digits]) at 18 C to 28 C, with relative humidity

More information

DIGITAL MULTIMETER DT4200 Series

DIGITAL MULTIMETER DT4200 Series DIGITAL MULTIMETER DT4200 Series DMM Super Fast Response Rate and Safety Features Take Professional Testing to a Higher Level High-End Models DT4281 / 4282 Standard Models DT4251 / 4252 / 4253 Pocket Models

More information

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515, LR8520 For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection Please see www.hioki.com

More information

Wide Spectrum Power Meter for Comprehensive Device Assessment

Wide Spectrum Power Meter for Comprehensive Device Assessment POWER HiTESTER 3193-10 Wide Spectrum Power Meter for Comprehensive Device Assessment Printer is optional unit DC/0.5Hz to 1MHz broad-band POWER HiTESTER measures up to 6 systems simultaneously. The POWER

More information

Model 6517B Electrometer / High Resistance Meter Specifications

Model 6517B Electrometer / High Resistance Meter Specifications VOLTS Accuracy (1 Year) 1 / C 2V 10µV 0.025+4 0.003+2 20V 100µV 0.025+3 0.002+1 200V 1mV 0.06+3 0.002+1 NMRR: 2V and 20V range > 60dB, 200V range > 55dB. 50Hz or 60Hz 2 CMRR: >120dB at DC, 50Hz or 60Hz.

More information

CATALOGO STRUMENTI Ricerca & Sviluppo

CATALOGO STRUMENTI Ricerca & Sviluppo CATALOGO STRUMENTI Ricerca & Sviluppo MISURE PRIMARIE OHMETRI MICROHMETRI MILLIOHMETRI SUPERMEGAOHMETRI TECNOLOGIA INDICE MISURE PRIMARIE Ohmetri Microhmetri-Milliohmetri -Supermegaohmetri...p 3 RM3543...p

More information

Data sheet IDM 99III Digital Multimeter

Data sheet IDM 99III Digital Multimeter RS Stock No. 7575116 Data sheet IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic DCV accuracy

More information

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger MEMORY HiLOGGER 8423 Data Logger Fast 10-ms Sampling Up to 600 Channels Data Logging MEMORY HiLOGGER Model 8423 is a data acquisition system capable of measuring and recording multiple channels at high

More information

CLAMP ON HiTESTER SERIES

CLAMP ON HiTESTER SERIES CLAMP ON HiTESTER SERIES Field Measuring Instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet DC CHARACTERISTICS [1] ACCURACY ± (% of reading + % of range) Temperature Cefficient

More information

Agilent 4285A Precision LCR Meter

Agilent 4285A Precision LCR Meter Agilent 4285A Precision LCR Meter Data Sheet Specifications The complete Agilent Technologies 4285A specifications are listed below. These specifications are the performance standards or limits against

More information

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application > LED OPTICAL METER TM6101 < Measurement image > TM 6101 consists of main unit + sensor unit + PC application software. (PC is not included) < Primary measurement application > White LED/LED lighting devices

More information

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI

More information

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

2300 REMOTE MEASUREMENT SYSTEM Data Logger

2300 REMOTE MEASUREMENT SYSTEM Data Logger 2004 2300 REMOTE MEASUREMENT SYSTEM Data Logger For quick-response handling of energy, quality, process, environmental, and fault issues Centralized Management of Multi Point Data There is a need for use

More information

HP 34401A Specifications 8

HP 34401A Specifications 8 8 HP 34401A Specifications 8 DC Characteristics DC Characteristics Accuracy Specifications ± ( % of reading + % of range ) [ 1 ] Function Range [ 3 ] Test Current or Burden Voltage 24 Hour [ 2 ] 23 C ±

More information

PRECISION COMPONENT ANALYZER 6430B / 6440B

PRECISION COMPONENT ANALYZER 6430B / 6440B PRECISION COMPONENT ANALYZER 6430B / 6440B Product Specification Issue B USA Wayne Kerr Electronics Inc. 165L New Boston Street Woburn MA 01801-1744 Tel: 781 938 8390 Fax: 781 933 9523 email: sales@waynekerr.com

More information

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual

More information

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX 756 & 7562 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is

More information

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph ENGLISH Datasheet Stock No. 123-3249 RS PRO IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic

More information

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A urrent Transducer ITZ 5000-SB FLEX ULTRASTAB I PM = 5000 A For ultra-high precision measurement of current: D, A, pulsed..., with galvanic separation between primary and secondary. Separate magnetic head

More information

Fast 10-ms Sampling Up to 600 Channels Data Logging. MEMORY HiLOGGER 8423

Fast 10-ms Sampling Up to 600 Channels Data Logging. MEMORY HiLOGGER 8423 MEMORY HiLOGGER 8423 Fast 10-ms Sampling Up to 600 Channels Data Logging MEMORY HiLOGGER Model 8423 is a data acquisition system capable of measuring and recording multiple channels at high speed. Acquired

More information

Agilent E4981A Capacitance Meter 120 Hz/ 1 khz/ 1 MHz. Data Sheet

Agilent E4981A Capacitance Meter 120 Hz/ 1 khz/ 1 MHz. Data Sheet Agilent E4981A Capacitance Meter 120 Hz/ 1 khz/ 1 MHz Data Sheet Definitions This document provides specifications and supplemental information for the Agilent E4981A 120 Hz / 1 khz / 1 MHz capacitance

More information

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback

More information

APPA 300 Series. The Most User-Friendly High Performance Multimeter

APPA 300 Series. The Most User-Friendly High Performance Multimeter APPA 300 Series The Most User-Friendly High Performance Multimeter Throw Away the Manual... So Easy, So Simple Straight Forward... For basic application, simply to operate these keys... "LIGHT" "BAR" "DIGIT"

More information

Resistance Meters for Production Lines and MRO. Easy to use with high-accuracy RESISTANCE METER RM3544, RM3548

Resistance Meters for Production Lines and MRO. Easy to use with high-accuracy RESISTANCE METER RM3544, RM3548 RESISTANCE METER RM3544, RM3548 Easy to use with high-accuracy Resistance Meters for Production Lines and MRO The Resistance Meters RM3544/RM3544-01/RM3548 can measure the winding resistance of devices

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER DSM-8104, DSM-8542

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER DSM-8104, DSM-8542 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com DIGITAL SUPER MEGOHMMETER, DIGITAL SUPER MEGOHMMETERS (Single-Channel) (Four-Channel) Options Supporting

More information

Data sheet IDM 98III Digital Multimeter

Data sheet IDM 98III Digital Multimeter RS Stock No. 7575110 Data sheet IDM 98III Digital Multimeter FEATURE: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.1% basic DCV accuracy

More information

Fluke 8845A/8846A Digital Multimeters Extended Specifications

Fluke 8845A/8846A Digital Multimeters Extended Specifications Fluke 8845A/8846A Digital Multimeters Extended Specifications The Fluke 8845A and 8846A 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements, on

More information

8588A Reference Multimeter

8588A Reference Multimeter 8588A Reference Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of

More information

DIGITAL STORAGE OSCILLOSCOPES

DIGITAL STORAGE OSCILLOSCOPES 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com DIGITAL STORAGE OSCILLOSCOPES Digital Storage Oscilloscope 100MS/s Acquisition (40MS/s 2 Acquisition) 100MHz 2 channel. OUTLINE

More information

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet Features 120000 counts resolution 16 built-in measurement functions including temperature and

More information

U1730C Series Handheld LCR Meters

U1730C Series Handheld LCR Meters DATA SHEET Take your expectations higher with the latest LCR meters U1730C Series Handheld LCR Meters The Keysight Technologies, Inc. U1730C Series handheld LCR meters allow you to measure at frequencies

More information