RADAR-BASED OPEN CHANNEL FLOW MEASUREMENT. Lawrence B. Marsh President Marsh-McBirney Inc Metropolitan Court Frederick, MD 21704

Size: px
Start display at page:

Download "RADAR-BASED OPEN CHANNEL FLOW MEASUREMENT. Lawrence B. Marsh President Marsh-McBirney Inc Metropolitan Court Frederick, MD 21704"

Transcription

1 RADAR-BASED OPEN CHANNEL FLOW MEASUREMENT ABSTRACT Lawrence B. Marsh President Marsh-McBirney Inc Metropolitan Court Frederick, MD This article is provided Courtesy of Winston Tang, M.A.Sc. EST Environmental Technologies. Exclusive Marsh McBirney Representative for British Columbia (604) The wastewater industry has relied upon the flume as the primary device for measurement of open channel wastewater flows. This method of open channel flow is achieved by placing a hydraulic structure (the flume) in the channel so as to produce a flow in the structure that is characterized by a known relationship between the liquid level, at a particular measurement location, and the flow rate of the stream. Advances in non-contact level measurement using ultrasonic level sensors (and, more recently, radar level measuring devices) have made the flume a very low-maintenance flowmeter that provides industry-acceptable accuracies of within ± 5% of reading. In the late 1970 s, a new type of open channel flowmeter was introduced into the wastewater industry. These flowmeters, called Area/Velocity flowmeters, relied upon the Continuity Equation, which states that flow (Q) is equal to the Average Velocity times the Area of the partially filled pipe. The advantage of the Area/Velocity flowmeter is that, unlike a flume, one flow device can be used on a variety of pipe shapes and sizes, without channel modification, therefore allowing the instrument to be easily transported and used between a variety of flow situations. Although Area/Velocity flowmeters have provided much needed data for control and engineering analysis throughout the wastewater industry, all of these meters tend to foul because they must be submerged in the flow to operate. Unlike a flume, these submerged sensors are subjected to error-causing buildup of grease and silt and hence, must be carefully maintained to keep operational. Recently, the first, non-contact type of Area/Velocity flowmeter was introduced to the industry one that uses non-contact Doppler Radar to measure velocity and ultrasonic pulse echo to measure depth. This device measures the surface velocity by reflecting microwaves off of the moving surface disturbances and converts these signals to the average velocity through an appropriate algorithm. The test results on one type of these Doppler Radar open channel flowmeters shows that it has the high rangability characteristic of Area/Velocity meters while having the low maintenance and accuracy characteristic of a flume. KEY WORDS Flow meter, open channel flow, Doppler Radar, microwaves, sewers, flumes

2 INTRODUCTION Over the past century, the wastewater industry has relied upon the flume as the primary device for measurement of open channel wastewater flows. This method of open channel flow is achieved by placing a hydraulic structure (flume) in the channel so as to produce a flow in the structure that is characterized by a known relationship between the liquid level, at a particular measurement location, and the flow rate of the stream. The shape and size of the flume needs to be carefully selected for both the channel size as well as expected flow rates, with most installations considered to be permanent. The Parshall flume, which was developed in the 1920 s by the U.S. Soil Conservation Service, has several advantageous characteristics. The design of the flume is such that it produces a discharge characteristic such that a single level measurement can be used to determine flow and the converging upstream portion of the flume causes the entering flow to speed up, helping to eliminate deposits of sediment that would otherwise affect the flow measurement accuracy. While early depth measurement at flumes was accomplished by hand or by floats, advances in non-contact level measurement using ultrasonic level sensors (and, more recently, radar level measuring devices) have made the flume into a very low-maintenance flowmeter that provides industry-acceptable accuracy of within ± 5% of reading. In the late 1970 s, a new type of open channel flowmeter began to enter the wastewater industry. These flowmeters, called area/velocity flowmeters, relied upon the Continuity Equation, which states that flow (Q) is equal to the Average Velocity (V x A ) times Area (A). See Fig. 1. Figure 1 IMPLEMENTATION OF CONTINUITY EQUATION Area /Velocity flowmeters utilize two independent measurements, one for measuring the depth of flow and the other, the velocity of flow. By knowing the cross-sectional area of the conduit, the level measurement is converted to the area 2

3 of the partially filled pipe and the sensed velocity is converted to average velocity by various proprietary algorithms. A description of one of the first systems is described in detail in US Patent No. 4,083,246. The advantage of the Area/Velocity flowmeter is that one flowmeter can be adapted to a variety of pipe shapes and sizes, therefore allowing the instrument to be easily transported and used between a variety of flow situations. The types of Area/Velocity instruments in use today include Continuous Wave Doppler (generally the least accurate, but lowest in cost), Pulsed Doppler (generally quite accurate), electromagnetic (the most widely used device) and Transit Time Ultrasonic (where highest accuracy and/or very large channels are required). While all of these Area/Velocity flowmeters have resulted in the increase of measurement of flows throughout the industry, all of these meters have had one, very weak point. All of the Area/Velocity flowmeters need to be submerged to operate. The Area/Velocity flowmeters are usually placed at or near the bottom of the conduit so as to measure flow at very low flow depths. Unfortunately, this places the sensor in such a location where it is easily covered with silt or rocks. Also, both the Doppler ultrasonic technology and electromagnetic technologies are such that grease coatings on the sensors can significantly affect the operation. Such sensor characteristics require a measurement site that must be carefully maintained by periodic cleaning of the sensor as well as choosing locations where silt build-up is not a problem. These maintenance issues create serious problems where such flowmeters are used for online chemical dosing or other on-line control. Of equal importance, but perhaps less critical, the loss of data from portable monitors used to gather engineering data throughout the collection system. In the mid-1990 s, Marsh-McBirney began a sustained development effort to create a non-contact, open channel Area/Velocity flowmeter that could be used in municipal and industrial wastewater systems. The goal of this design was to create a modern day replacement of the flume that would provide the user with a low-maintenance, highly reliable flowmeter that could be used in various pipe sizes and shapes, from pipes as small as 10 mm in diameter to channels that are up to 3 meters or more in width. The accuracy goal under a broad range of flow conditions was set to be ± 5% of reading. In choosing a technology for a non-contact velocity sensor several technologies were considered. We observed that radar devices were being designed into the next generation of luxury automobiles for collision avoidance and speed controls. This proliferation of radar devices into the consumer market was driving the cost of microwave components down as well as helping create the design of devices with low power consumption that could be used in portable, battery operated devices. The flowmeter resulting from this development effort utilizes microwave Doppler radar to measure velocity and an acoustic transducer to measure depth. See Figures 2 and 3. 3

4 Figure 2 DOPPLER RADAR SENSOR Figure 3 FOOTPRINTS OF THE DOPPLER RADAR VELOCITY AND ULTRASONIC LEVEL SENSORS HOW DOES RADAR WORK? The basic principle of radar is its capability to reflect off of the surface of materials, based on the material s dielectric constant. Any materials that has a dielectric constant greater than 2, such as water, crude oil or ammonia, will easily reflect the microwave, radar signals. The higher the dielectric constant of the material, the more signal that is reflected and is available for processing. On the other hand, radar signals tend to pass through materials that have a dielectric constant less than two, such as air, vapor, certain gases or foam. Thus foam and variable gases have minimal effect on radar measurements as compared with other measurement technologies. Radar flowmeters determine the velocity of the flow similar to how radar guns measure the velocity of a baseball or an automobile. The radar beam is transmitted from the sensor s horn at a defined angle to the flow surface. This 4

5 transmitted beam interacts with the fluid and reflects back a portion of the transmitted signal. The portion of the signal that is reflected back is at a slightly different frequency than that which was transmitted. For instance, the frequency of the returning signal is slightly higher if the flow is coming toward the beam and is slightly lower if the flow is going away from the beam. Reflected signals that returned to the radar horn are detected and compared to the transmitted frequency. The difference frequency, the Doppler frequency, is a direct measure both of velocity and of the direction of the flow particles from which the signal was reflected. Radar-based open channel flowmeters require some degree of surface and near-surface roughness so that a portion of the transmitted signal will be returned to the radar receiver. A mirror-like surface will cause the transmitted signal to completely escape; however, in nearly all real-life situations, there will be adequate reflections for accurate, reliable measurement. The frequency chosen was 24 GHz. This frequency was chosen because of its short wavelength that allows the sensor to measure velocities with a minimal amount of surface disturbance. Also, the chosen frequency is license-free to the user. The processing of the returned signals from the surface of the flow is performed by a sophisticated FFT processing circuit. This Fast Fourier Transform (FFT) circuit takes samples of the returning signals and transforms these signals into an energy spectrum that defines where the major concentrations of energy lie and hence what the surface flow velocity is. The Doppler frequencies are calibrated at 128 Hz per m/s. Figure 4 EXAMPLE OF FFT ENERGY SPECTRUM The returning signals from the flow surface are usually very distinct as shown in Fig. 4. This energy hump is centered at a Doppler frequency of 155 Hz, which is equal to 1.15 m/s (3.8 ft/sec). Under most conditions the returning Doppler signals are typical of that shown in Figure 4. However, under windy, outside conditions or when the energy slope is very flat there is an increase in noise sources that begins to compete with the actual flow signal. Algorithms have been developed for a number of situations to eliminate problems, and development 5

6 continues so as to extend the range of the radar flowmeter into a number of very difficult applications. The accurate measurement of open channel flow requires the accurate measurement of the mean velocity of the flow stream. The radar open channel flowmeter, like other flowmeters, does not directly measure the mean velocity of the flow stream directly. Like other flowmeters, it must augment the sensed velocity with a relationship that converts the sensed velocity to the mean velocity. Since the position of the beam relative to the flow surface is known (it is generally in the center of the channel, but can be elsewhere) algorithms defining the relationship between the sensed velocity and the average velocity of the flow stream can be determined to an accuracy of ± 5% or better. Referring to Fig. 5 and 6, we see that the flow in an open channel situation consists of a contour of velocities that vary from near zero at the channel walls to a maximum just below the surface. Figure 5 VELOCITY PROFILE IN CIRCULAR PIPE Figure 6 VELOCITY PROFILE IN RECTANGULAR PIPE Note, also, that the various velocity profile lines generally terminate along the surface of the flow. In other words, a fingerprint of the flow profiles exists on the surface itself. By analyzing the surface and near-surface fingerprint of the flow channel, a relationship between where the radar-sensed velocity occurs and the average velocity of the flow stream can be determined to a reasonable accuracy. While currently available radar open channel flowmeters rely upon this relationship of sensed velocity to average velocity at the center of the pipe, it is expected that an algorithm will soon be available that will enable the radar flowmeter to provide accurate flow under distorted flow situations. Like all flowmetering devices, for best accuracy the flow needs to be reasonably uniform in nature. Making a flow measurement near bends and elbows or downstream from major disturbances can significantly distort the flow profile and result in a less accurate measurement. METHODOLOGY Open channel flows exist as part of many natural and man-made processes. Essentially, open channel flow is flow in which there is a free surface. The flow 6

7 channels are a common site to all of us they include rivers, aqueducts, and sanitary and storm sewers. The range of flows in these systems varies from just a trickle to a raging torrent. The channel sizes of interest are as small as a 100 mm pipe to a river tens of meters wide. The testing criteria for this new radar flow sensor was designed to include both small and mid-size manmade channels over a variety of flow ranges covering a span virtually empty to nearly full capacity. Because the radar flow sensor requires a free surface, a simply designed radar unit will not be able to detect velocities under submerged conditions. Therefore no tests were preformed under surcharged or submerged conditions. HYDRAULIC FACILITIES Marsh-McBirney maintains a hydraulic research facility in its plant in Frederick, MD. This facility consists of a towing carriage that is 1.5 meters wide by 1.5 meters deep and is approximately 40 meters long. Marsh-McBirney also maintains a recirculating flow facility with a volume tank for calibration. Two magnetic flowmeters are used as secondary standards in the full-pipe section of the hydraulic facility. The facility has the ability to use various pipe sizes from 100 mm to 400 mm in diameter under open channel conditions where both the flow rate and the pipe slope can be independently controlled. To develop the necessary algorithms for converting surface velocity to average velocity, Marsh-McBirney used its internal flow facility and a number of field sites that had either 1) carefully calibrated flowmeters previously installed or 2) was calibrated by using velocity profiling of the site with a point velocity meter at different flow rates. RESULTS Laboratory Results Developmental tests were performed in 250 mm and 400 mm diameter circular pipes. Flow depths ranged from 5 mm to 70 % full. The test flowmeter exhibited a high degree of repeatability (+/- 3 %) over a variety of pipe slopes ranging from 0.25 % to 7 %. Application of a depth dependent corrector resulted in a typical accuracy of +/- 5 %. Field Experience Doppler Radar flowmeter have been used in the field in hundreds of applications; circular pipes as small as 15 mm in diameter and as large as 2 meters in diameter. Additionally, large rectangular channels up to 3 meters in width have 7

8 been instrumented as well as a variety of common pipe sizes used in wastewater collection systems. Some interesting applications are as follows: In Line with a Flume At Washington Suburban Sanitary Commission (WSSC), Washington, DC, a new, small grit moving-screen filter system had been installed in-line with one of four flumes used for monitoring the plant influent into the treatment process. Unfortunately, the filters were so effective that they collected excessive debris such that the outflow from the chambers was slowed, causing the flumes to be submerged under heavy inflow. Figure 7 DOPPLER RADAR FLOWMETER IN-LINE WITH FLUME A Doppler radar meter was installed upstream from the Parshall flume and its calibration checked at various flow rates with a point velocity meter and a hand held depth gauge. Fig 7 shows the reported data from both the radar meter and the Parshall flume inline with the radar meter. Note that for flows less than 12 MGD the flume and the radar meter track each other within ± 5%. However, as flow increased from the inflow from storm, the flow rates between the flume and the radar device deviated very significantly, with the flume flow being higher than thought reasonable. Shown also on this graph are the spot flow checks made by the handheld velocity meter and level device. Note that the flow check using the handheld velocity meter shows that the Flo-Dar was reporting within ± 5% of the handheld device, whereas the flume was over reporting flow by 30%. 8

9 Of additional interest is that during various tests at the site, it was observed that the velocity/level relationship varied significantly once the flume was submerged, but accuracies continued to be within the ± 5% range. Steep Terrain In steep terrain the flow velocities can be very fast, approaching 3 m/s or faster. These velocities can occur with both shallow and deep water depths. Figure 8 shows a scatter graph of the velocity/level relationship of such a condition. Because there is no sensor in the flow, one does not have to worry about the drawdown effect typical of many pressure transducer based level devices and the flow remains undisturbed while the measurement is being made. Figure 8 - SCATTER PLOT OF STEEP SLOPED SITE In-Line with an EM meter Because the radar-based flowmeter is extremely portable and does not require the placement of bands or other apparatus in the flow stream, it lends itself to being easily transported from one site to another. Fig. 9 shows the results of a comparison study of a radar meter installed in 600 mm sewer along with an electromagnetic flowmeter. 9

10 Figure 9 - COMPARISON OF DOPPLER RADAR FLOWMETER WITH ELECTROMAGNETIC FLOWMETER COMPARISON OF ATTRIBUTES OF VARIOUS FLOWMETERS From 30 years of personal experience in designing and testing various flowmeters for the wastewater field and from information gleamed from many articles, the author has assembled comparison charts for the attributes of various flowmeters. Table 1 shows a comparison of attributes of the flume with various type area/velocity flowmeters. Note that the accuracy of the various submerged flowmeters varies as well as the flow range from the maximum flow that they can accurately measure to the minimum flow that they can actually measure. Of all the submersible type flowmeters, the transit time technique tends to be the most accurate. However, transit time instruments are typically used only in large channels since they require a minimum flow depth to operate. Ease of installation is an important aspect of flowmeters, especially those that are transported from one site to another. In small pipes of 600 mm or less in diameter, most of the submersible flowmeters can be installed with only moderate difficulty. However, in pipe sizes of greater than 600 mm most of the submerged sensors become very difficult to install, due to the danger and the forces involved in installing sensors at the bottom of a pipe carrying significant flow. The power requirement of the radar flowmeter is comparable to that used by other area/velocity flowmeters. For instance, for typical applications where data is collected once every 15 minutes, the radar portable flowmeter batteries can last as long as 12 weeks. Portable radar flowmeters are designed with dataloggers similar to other area/velocity meters where the user can use laptop computers to extract the data and proprietary software to obtain the necessary data in desirable formats. 10

11 Table 1 - COMPARISON OF FLUME WITH VARIOUS AREA/VELOCITY FLOWMETERS Installation Difficulty Submerged Flowmeter Type Accuracy CW Doppler +/-10-20% 100:1 Channel Width Flow Range <600mm >600mm Maintenance Easy to moderate Pulse Doppler +/-2-5% 200:1 Moderate Electromagnetic +/-5% 100:1 Transit Time +/-2% 200:1 Easy to moderate Difficult-Very Difficult Difficult-Very Difficult Difficult-Very Difficult Med-High Med-High Med-High Moderate- Difficult Very Difficult Med Non-Contact Flume +/-5% 20:1 Difficult Very Difficult Low Doppler Radar +/-5% 500:1 Easy Easy Low MAINTENANCE Low maintenance competes with accuracy as the most important feature of a wastewater flowmeter. The days of having the time to tinker with new-fangled flowmeters are over. Table 2 discusses some of the maintenance issues associated with most flowmeters in use in wastewater systems today. The major causes of maintenance for submerged sensors are grease, silt, hang-ups on the sensor, and caustic or temperature deterioration of the submerged sensors. It is easy to see that most submerged sensors are affected to at least a medium extent by grease and silt and hang-ups causing erroneous readings and the need to visit the site to clean. Caustic substances and temperature affects tend to have harmful affects that ultimately result in the failure of the submerged sensor. Unlike the submerged sensors, the Doppler radar is much more like the flume. It is immune to grease, silt, hang-ups or the general make-up and temperature of the flowing fluid. 11

12 Table 2 - COMPARISON OF MAINTENANCE ISSUES OF VARIOUS FLOWMETERS Fouling Environment Flowmeter Type Grease Silt Hang-Up Caustics Submerged CW Doppler P-F P P-F F-G Pulse Doppler P-F P P-F F-G Electromagnetic P-F P P-F F-G Transit Time G-E Note: 1 G-E F-G Non-Contact Flume E E E E Doppler Radar E E E E Comparison of Ease of Maintenance between Flowmeter Types P= Poor, F= Fair, G= Good, E= Excellent Note 1- Sensor is located several inches above the channel bottom. CONCLUSIONS Doppler Radar open channel flowmeters currently have been developed to such an extent that they provide a very attractive alternative to flumes. There are, however, two areas where Doppler Radar is not currently the right choice: 1) a flow where velocities go below approximately 15 cm/s (0.5 ft/sec) and the slope of the pipe is such that the water surface is very tranquil. Signal dropouts may occur and 2) submerged flow in which no reflections occur and data goes to zero. Developments are underway to provide the user with the means of obtaining velocity measurements during submergence. It is this author s opinion that the Doppler Radar flowmeter has an accuracy equivalent to the flume; has a rangeability 50 times greater than the flume; is much easier to install than a flume, regardless of pipe size or channel size; and, unlike submerged Area/Velocity sensors, has the same low maintenance exhibited by the flume. Also, like a flume, it is unable to measure submerged flows without an additional sensor. 12

Flow Monitoring Product Guide

Flow Monitoring Product Guide Monitoring Product Guide 2100 Series Modules Velocity Profiling 4200 Series 3010 Transmitter 4501 Pump Station Monitor Advanced Products From Teledyne Isco Offering a wide range of flow instruments and

More information

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016 Advancements in Clamp-on Ultrasonic Flow Measurements 2016 Biosolids Workshop December 1 st 2016 Market Leader in Clamp-On Ultrasonic Flowmeters with >50,000 instruments sold Background Information Extraordinary

More information

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS

More information

Propagation of Electromagnetic Waves

Propagation of Electromagnetic Waves Propagation of Electromagnetic Waves REFLECTOR (Water) RADAR ANTENNA Speed of electromagnetic waves used in radar = 300,000,000m/s Speed of electromagnetic waves changes due to temperature, pressure and

More information

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster HOW TO SELECT A CONTINUOUS LEVEL SENSOR Jenny Christensen Todd Peterson BinMaster 1 Using a continuous level sensor to monitor the material level in your storage vessels can help you keep material flowing

More information

ABB flowmeter technology FSM4000 AC-excited magmeter

ABB flowmeter technology FSM4000 AC-excited magmeter White paper ABB flowmeter technology FSM4000 AC-excited magmeter Innovative AC-excited magmeter benefits pulp and paper operations by Greg Livelli, ABB Measurement Products Design innovations in AC-excited

More information

InstrumentationTools.com

InstrumentationTools.com Author: Instrumentation Tools Categories: Level Measurement Ultrasonic Level Measurement Ultrasonic level instruments measure the distance from the transmitter (located at some high point) to the surface

More information

Innovative Parabolic Depth Sensor Allows Agencies to Detect Growing Blockages, Conduct Micro-metering and Measure CSOs

Innovative Parabolic Depth Sensor Allows Agencies to Detect Growing Blockages, Conduct Micro-metering and Measure CSOs Innovative Parabolic Depth Sensor Allows Agencies to Detect Growing Blockages, Conduct Micro-metering and Measure CSOs Patrick Stevens, PE, ADS Kevin Enfinger, PE, ADS ABSTRACT Dozens of sewer agencies

More information

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF)

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF) Products Solutions Services Level Measurement Transmitters Applying Level Measurement Ultrasonic FDU95 FDU93 FDU92 FDU91 FDU90 Slide 1 Slide 2 The Principle Time of Flight (TOF) Emission of ultrasound

More information

Level Measurement Products Installation Considerations-Radar

Level Measurement Products Installation Considerations-Radar Siemens Industry, Inc / IA / Process Instruments Level Measurement Products Installation Considerations-Radar Restricted Siemens Industry, Inc. 2015 All rights reserved. Answers for industry. Radar Measures

More information

Acoustic Filter Copyright Ultrasonic Noise Acoustic Filters

Acoustic Filter Copyright Ultrasonic Noise Acoustic Filters OVERVIEW Ultrasonic Noise Acoustic Filters JAMES E. GALLAGHER, P.E. Savant Measurement Corporation Kingwood, TX USA The increasing use of Multi-path ultrasonic meters for natural gas applications has lead

More information

Acoustic Velocity Independent Ultrasonic Flow-Meter

Acoustic Velocity Independent Ultrasonic Flow-Meter flotek.g 2017- Innovative Solutions in Flow Measurement and Control - Oil, Water and Gas August 28-30, 2017, FCRI, Palakkad, Kerala, India Acoustic Velocity Independent Ultrasonic Flow-Meter ABSTRACT Shalini

More information

SITRANS LR 300: High Performance Radar for Level Measurement

SITRANS LR 300: High Performance Radar for Level Measurement SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,

More information

HOW TO SELECT A CONTINUOUS LEVEL SENSOR WHITEPAPER

HOW TO SELECT A CONTINUOUS LEVEL SENSOR WHITEPAPER WHITEPAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR Using a continuous level sensor to monitor the material level in your storage vessels can help your operation maintain efficiency preventing costly process

More information

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Technologies, Solutions, and Applications. Guided Wave Radar for Level Technologies, Solutions, and Applications Guided Wave Radar for Level Contents Leadership in Guided Wave Radar 3 Principles of Operation 4 Models and Versions 5 Guided Wave Radar in the plics System 8

More information

Phased Array Velocity Sensor Operational Advantages and Data Analysis

Phased Array Velocity Sensor Operational Advantages and Data Analysis Phased Array Velocity Sensor Operational Advantages and Data Analysis Matt Burdyny, Omer Poroy and Dr. Peter Spain Abstract - In recent years the underwater navigation industry has expanded into more diverse

More information

An acousto-electromagnetic sensor for locating land mines

An acousto-electromagnetic sensor for locating land mines An acousto-electromagnetic sensor for locating land mines Waymond R. Scott, Jr. a, Chistoph Schroeder a and James S. Martin b a School of Electrical and Computer Engineering b School of Mechanical Engineering

More information

Marketing Communications

Marketing Communications More than precise measuring New instrument diagnostic concepts offer interesting approaches for process optimization Due to high reliability and accuracy, low maintenance requirements, low power consumption

More information

NON-TRADITIONAL MACHINING PROCESSES ULTRASONIC, ELECTRO-DISCHARGE MACHINING (EDM), ELECTRO-CHEMICAL MACHINING (ECM)

NON-TRADITIONAL MACHINING PROCESSES ULTRASONIC, ELECTRO-DISCHARGE MACHINING (EDM), ELECTRO-CHEMICAL MACHINING (ECM) NON-TRADITIONAL MACHINING PROCESSES ULTRASONIC, ELECTRO-DISCHARGE MACHINING (EDM), ELECTRO-CHEMICAL MACHINING (ECM) A machining process is called non-traditional if its material removal mechanism is basically

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications

Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications Optimize your Ultrasonic Flow Meter for Water & Wastewater Applications Standards Certification Education & Training Publishing Conferences & Exhibits Speaker: Brent Baird, Instruments Direct 2013 ISA

More information

BRIDLE & STILLING WELL LEVEL MEASUREMENT. FEATURING THE VEGAflex 60 SERIES

BRIDLE & STILLING WELL LEVEL MEASUREMENT. FEATURING THE VEGAflex 60 SERIES BRIDLE & STILLING WELL LEVEL MEASUREMENT FEATURING THE VEGAflex 60 SERIES PIPE MEASUREMENT WHY USE GUIDED MICROWAVE? Level measurement that requires using a pipe comes with a set of conditions that can

More information

Basics of continuous level measurements. By Gene Henry, Level Product Marketing Manager, Endress+Hauser. d = c 2

Basics of continuous level measurements. By Gene Henry, Level Product Marketing Manager, Endress+Hauser. d = c 2 Basics of continuous level measurements By Gene Henry, Level Product Marketing Manager, Endress+Hauser The most common technologies available for continuous level measurement are ultrasonic, free space

More information

Advancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017

Advancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017 Advancements in Clamp-on Ultrasonic Flow Measurements Ohio Section AWWA SE District Fall Meeting September 1 st 2017 About Us - Providing Measurement instrumentation and data collection since 1984 - State

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Ultrasonic Transmitters vs. Guided Wave Radar for Level Measurement

Ultrasonic Transmitters vs. Guided Wave Radar for Level Measurement WHITE PAPER Ultrasonic Transmitters vs. Guided Wave Radar for Level Measurement INTRODUCTION With over 20 different level measurement technologies on the market today, it is important to choose the right

More information

INSTALLATION & MAINTENANCE

INSTALLATION & MAINTENANCE ADVANTAGES High measurement precision of surface velocity due to advanced radar technology Fast installation above the surface, no complex construction works, or flow shutdown required 24/7 real-time monitoring

More information

Using Microwave Sensors to Measure Moisture Levels in Mozzarella Cheese

Using Microwave Sensors to Measure Moisture Levels in Mozzarella Cheese Using Microwave Sensors to Measure Moisture Levels in Mozzarella Cheese Why Microwave Resonator-Based Sensors Are the Ideal Approach for Accurately Measuring Moisture in Food Products By Hinrich Roemhild,

More information

A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS

A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS R.Prabhu Jude, L.Sridevi, Dr.P.Kanagasabapathy Madras Institute Of Technology, Anna University, Chennai - 600 044. ABSTRACT This paper describes

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT) Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT) Author: Ankit Vajpayee Russell NDE Systems Inc. 4909 75Ave Edmonton, Alberta, Canada T6B 2S3 Phone 780-468-6800

More information

Sonic Distance Sensors

Sonic Distance Sensors Sonic Distance Sensors Introduction - Sound is transmitted through the propagation of pressure in the air. - The speed of sound in the air is normally 331m/sec at 0 o C. - Two of the important characteristics

More information

Understanding How Frequency, Beam Patterns of Transducers, and Reflection Characteristics of Targets Affect the Performance of Ultrasonic Sensors

Understanding How Frequency, Beam Patterns of Transducers, and Reflection Characteristics of Targets Affect the Performance of Ultrasonic Sensors Characteristics of Targets Affect the Performance of Ultrasonic Sensors By Donald P. Massa, President and CTO of Massa Products Corporation Overview of How an Ultrasonic Sensor Functions Ultrasonic sensors

More information

OPTITEMP. Compact sensors

OPTITEMP. Compact sensors OPTITEMP Compact sensors High process accuracy thanks to great long-term stability, quick response time and high measuring accuracy High reliability due to the robust design Small form factor, suitable

More information

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.

More information

OIL AND WATER SEPARATION AT ITS BEST

OIL AND WATER SEPARATION AT ITS BEST OIL AND WATER SEPARATION AT ITS BEST Looking for faster and more efficient separation of produced water from crude oil as well as increased production? Vessel Internal Electrostatic Coalescers (VIEC) have

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

SonTek 3.0-Mhz RiverCAT ADP Demonstration on the

SonTek 3.0-Mhz RiverCAT ADP Demonstration on the SonTek/YSI, Inc. 6837 Nancy Ridge Drive Suite A San Diego, CA 92121 USA SonTek 3.0-Mhz RiverCAT ADP Demonstration on the.......... Orange River River near Aliwal North, Free State, South Africa Results

More information

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers 84-3-424, Rev BA May 29 Rosemount Radar Transmitters Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers INTRODUCTION This document provides a guideline for choosing and

More information

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK. Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK. A Sarasota 2000 Ultrasonic flowmeter, installed at Watchgate water treatment works in Cumbria on the 2.4m

More information

UNIT-4 POWER QUALITY MONITORING

UNIT-4 POWER QUALITY MONITORING UNIT-4 POWER QUALITY MONITORING Terms and Definitions Spectrum analyzer Swept heterodyne technique FFT (or) digital technique tracking generator harmonic analyzer An instrument used for the analysis and

More information

Design Data 12M. Hydraulic Capacity of Precast Concrete Boxes. RISE, Millimeters. Span Millimeters

Design Data 12M. Hydraulic Capacity of Precast Concrete Boxes. RISE, Millimeters. Span Millimeters Design Data 12M Hydraulic Capacity of Precast Concrete Boxes Under certain conditions the hydraulic or structural characteristics of reinforced concrete box sections offer advantages over the circular

More information

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD) EMAT Application on Incoloy furnace Tubing By Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD) Outlines 1. Introduction EMAT 2. EMAT- Ultrasound waves 3. EMAT-Surface waves 4. EMAT-Guided

More information

For crossing under a railroad, contact the specific railroad company's engineering department.

For crossing under a railroad, contact the specific railroad company's engineering department. PAGE 330524-1 SECTION 330524 SPECIFIER: This section is for the underground installation of piping by directional drilling. When specifying this method of piping installation, care must be taken to ensure

More information

ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT BY UTILZING SHEAR WAVES IN METAL PIPE

ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT BY UTILZING SHEAR WAVES IN METAL PIPE 4th International Symposium on Ultrasonic Doppler Method for Fluid Mechanics and Fluid Engineering Sapporo, 6.-8. September, 24 ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT

More information

Radar and Wind Farms. Dr Laith Rashid Prof Anthony Brown. The University of Manchester

Radar and Wind Farms. Dr Laith Rashid Prof Anthony Brown. The University of Manchester Radar and Wind Farms Dr Laith Rashid Prof Anthony Brown The Microwave and Communication Systems Research Group School of Electrical and Electronic Engineering The University of Manchester Summary Introduction

More information

The Probe KK&S INSTRUMENTS - April / June 2013

The Probe KK&S INSTRUMENTS - April / June 2013 Issue 10 The Probe KK&S INSTRUMENTS - April / June 2013 In this issue: 1. Cover Story Sigmascope Conductivity Meter 2. Special 15% OFF Echograph Flaw Detectors 3. News NEW Echometer 1077 Precession & 1077K

More information

Applicability of Ultrasonic Pulsed Doppler for Fast Flow-Metering

Applicability of Ultrasonic Pulsed Doppler for Fast Flow-Metering Applicability of Ultrasonic Pulsed Doppler for Fast Flow-Metering Stéphane Fischer (1), Claude Rebattet (2) and Damien Dufour (1), (1) UBERTONE SAS, 4 rue Boussingault Strasbourg, France, www.ubertone.com

More information

Ultrasonic Level Transmitters (Optional Exercise)

Ultrasonic Level Transmitters (Optional Exercise) Exercise 4-6 Ultrasonic Level Transmitters (Optional Exercise) EXERCISE OBJECTIVE In this exercise, you will study how ultrasonic level transmitters operate. You will measure level in a column using an

More information

The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters

The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters Utah State University DigitalCommons@USU All Graduate Theses and Dissertations Graduate Studies 2016 The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters Jared

More information

SOLVED MEASUREMENT COMMUNICATION INSIGHT

SOLVED MEASUREMENT COMMUNICATION INSIGHT SEDIMENT? SOLVED MEASUREMENT COMMUNICATION INSIGHT CONTENTS Sediment? Solved. AQUAlogger 210TY SSC Converter The Acoustic Profiler AQUAscat 1000 range AQUAscat 1000R AQUAscat 1000S AQUAscat 1000LT AQUAscat

More information

wprime TM Series 280W-CI ULTRASONIC WATER METER

wprime TM Series 280W-CI ULTRASONIC WATER METER MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water

More information

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved. Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical

More information

Manual of Petroleum Measurement Standards Chapter 5 Metering

Manual of Petroleum Measurement Standards Chapter 5 Metering "This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

Flowrate Measurement Background

Flowrate Measurement Background A Report of Acoustic Transit Time Accuracy Field Work Performed In North America By James T. Walsh Director Accusonic Technologies Flowrate Measurement Background The use of multiple path acoustic transit

More information

CLAMP-ON ULTRASONIC FLOW METER APPLICATION AND PERFORMANCE WILLIAM E. FRASIER RETIRED CASEY HODGES CEESI MEASUREMENT SOLUTIONS

CLAMP-ON ULTRASONIC FLOW METER APPLICATION AND PERFORMANCE WILLIAM E. FRASIER RETIRED CASEY HODGES CEESI MEASUREMENT SOLUTIONS CLAMP-ON ULTRASONIC FLOW METER APPLICATION AND PERFORMANCE WILLIAM E. FRASIER RETIRED CASEY HODGES CEESI MEASUREMENT SOLUTIONS JOE NETTLETON RT TECHNICALSOLUTIONS This paper is directed to ultrasonic natural

More information

Accurate Low Flow Rate Measurement Using a Specially Designed Differential Pressure Type Flowmeter

Accurate Low Flow Rate Measurement Using a Specially Designed Differential Pressure Type Flowmeter Accurate Low Flow Rate Measurement Using a Specially Designed Differential Pressure Type Flowmeter By: Bruce Brigg Source: Primary Flow Signal, Inc. All flow measurement technologies have inherent limitations

More information

Proximity Sensors Ultrasonic Precision Proximity Sensors

Proximity Sensors Ultrasonic Precision Proximity Sensors Ultrasonic Precision Proximity Sensors 900 Series ultrasonic position sensors solve the toughest sensing problems. Ultrasonic sensors detect targets made of virtually any material, regardless of color.

More information

EnviroRanger ERS 500. Programming Reference PL-556 Nov Rev 2.0

EnviroRanger ERS 500. Programming Reference PL-556 Nov Rev 2.0 EnviroRanger ERS 500 Programming Reference PL-556 Nov. 1999 trial 33455560 Rev 2.0 Ultrasonic level Radar At Milltronics, we endeavour to design equipment that is simple to use and reliable in its operation,

More information

SITRANS L Level instruments

SITRANS L Level instruments SITRANS L Level instruments /2 Point level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Electro-mechanical switches

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

Optimal Flow Measurement: Understanding Selection, Application, Installation, and Operation of Flowmeters

Optimal Flow Measurement: Understanding Selection, Application, Installation, and Operation of Flowmeters Electronic Publication Optimal Flow Measurement: Understanding Selection, Application, Installation, and Operation of Flowmeters ITA Prepared by the ITA 2002 Workshop Task Force Dr. Richard Furness John

More information

ULTRASONIC FLOW METER FT101

ULTRASONIC FLOW METER FT101 Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that

More information

Effect of coupling conditions on ultrasonic echo parameters

Effect of coupling conditions on ultrasonic echo parameters J. Pure Appl. Ultrason. 27 (2005) pp. 70-79 Effect of coupling conditions on ultrasonic echo parameters ASHOK KUMAR, NIDHI GUPTA, REETA GUPTA and YUDHISTHER KUMAR Ultrasonic Standards, National Physical

More information

Active and Passive Microwave Remote Sensing

Active and Passive Microwave Remote Sensing Active and Passive Microwave Remote Sensing Passive remote sensing system record EMR that was reflected (e.g., blue, green, red, and near IR) or emitted (e.g., thermal IR) from the surface of the Earth.

More information

Applications Features

Applications Features GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system

More information

WATERFLUX 3070 Technical Datasheet

WATERFLUX 3070 Technical Datasheet WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone

More information

DESIGN OF GLOBAL SAW RFID TAG DEVICES C. S. Hartmann, P. Brown, and J. Bellamy RF SAW, Inc., 900 Alpha Drive Ste 400, Richardson, TX, U.S.A.

DESIGN OF GLOBAL SAW RFID TAG DEVICES C. S. Hartmann, P. Brown, and J. Bellamy RF SAW, Inc., 900 Alpha Drive Ste 400, Richardson, TX, U.S.A. DESIGN OF GLOBAL SAW RFID TAG DEVICES C. S. Hartmann, P. Brown, and J. Bellamy RF SAW, Inc., 900 Alpha Drive Ste 400, Richardson, TX, U.S.A., 75081 Abstract - The Global SAW Tag [1] is projected to be

More information

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot

More information

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions About Ophir-Spiricon With over 30 years of experience, the Ophir Photonics Group provides a complete line of instrumentation including power and energy meters, beam profilers, spectrum analyzers, and goniometric

More information

THE NATURE OF GROUND CLUTTER AFFECTING RADAR PERFORMANCE MOHAMMED J. AL SUMIADAEE

THE NATURE OF GROUND CLUTTER AFFECTING RADAR PERFORMANCE MOHAMMED J. AL SUMIADAEE International Journal of Electronics, Communication & Instrumentation Engineering Research and Development (IJECIERD) ISSN(P): 2249-684X; ISSN(E): 2249-7951 Vol. 6, Issue 2, Apr 2016, 7-14 TJPRC Pvt. Ltd.

More information

Guided Wave Radar vs. Non-Contact Radar for Level Measurement

Guided Wave Radar vs. Non-Contact Radar for Level Measurement WHITE PAPER Guided Wave Radar vs. Non-Contact Radar for Level Measurement INTRODUCTION Two of the most commonly used types of radar transmitters on the market today is Guided Wave Radar and Non-Contact

More information

MEASUREMENT OF RAYLEIGH WAVE ATTENUATION IN GRANITE USING

MEASUREMENT OF RAYLEIGH WAVE ATTENUATION IN GRANITE USING MEASUREMENT OF RAYLEIGH WAVE ATTENUATION IN GRANITE USING LASER ULTRASONICS Joseph O. Owino and Laurence J. Jacobs School of Civil and Environmental Engineering Georgia Institute of Technology Atlanta

More information

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies Tapped Horn (patent pending) Horns have been used for decades in sound reinforcement to increase the loading on the loudspeaker driver. This is done to increase the power transfer from the driver to the

More information

Frequency and Antenna Selection Effects on Accuracy of Free Space Radar

Frequency and Antenna Selection Effects on Accuracy of Free Space Radar Frequency and Antenna Selection Effects on Accuracy of Free Space Radar Accuracy of free space radar depends on frequency, beam angle, antenna configuration and installation. By: Bill Sholette, Level Product

More information

Fuji Ultrasonic Flowmeter Series

Fuji Ultrasonic Flowmeter Series Fuji Ultrasonic Flowmeter Series 21A1-E-0008 Features of ultrasonic flowmeter in flow rate measurement 1. Total cost reduction allowed by elimination of piping installation 2. Can be installed even while

More information

The use of high frequency transducers, MHz, allowing the resolution to target a few cm thick in the first half meter suspect.

The use of high frequency transducers, MHz, allowing the resolution to target a few cm thick in the first half meter suspect. METHODOLOGY GPR (GROUND PROBING RADAR). In recent years the methodology GPR (Ground Probing Radar) has been applied with increasing success under the NDT thanks to the high speed and resolving power. As

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement INTERNATIONAL STANDARD ISO 16809 First edition 2012-11-15 Non-destructive testing Ultrasonic thickness measurement Essais non destructifs Mesurage de l'épaisseur par ultrasons Reference number ISO 2012

More information

4.6.1 Waves in air, fluids and solids Transverse and longitudinal waves Properties of waves

4.6.1 Waves in air, fluids and solids Transverse and longitudinal waves Properties of waves 4.6 Waves Wave behaviour is common in both natural and man-made systems. Waves carry energy from one place to another and can also carry information. Designing comfortable and safe structures such as bridges,

More information

7. Consider the following common offset gather collected with GPR.

7. Consider the following common offset gather collected with GPR. Questions: GPR 1. Which of the following statements is incorrect when considering skin depth in GPR a. Skin depth is the distance at which the signal amplitude has decreased by a factor of 1/e b. Skin

More information

FISCHER CUSTOM COMMUNICATIONS, INC.

FISCHER CUSTOM COMMUNICATIONS, INC. FISCHER CUSTOM COMMUNICATIONS, INC. Current Probe Catalog FISCHER CUSTOM COMMUNICATIONS, INC. Fischer Custom Communications, Inc., is a manufacturer of custom electric and magnetic field sensors for military

More information

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement The Lecture Contains: Sources of Error in Measurement Signal-To-Noise Ratio Analog-to-Digital Conversion of Measurement Data A/D Conversion Digitalization Errors due to A/D Conversion file:///g /optical_measurement/lecture2/2_1.htm[5/7/2012

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS Rev04009 USER MANUAL DEI MODEL USFT-CS USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER The Model USFT-CS is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Clamp-on Ultrasonic Flow Meter Family System 1010P and 1010WP Portable Clamp-On Multifunction Ultrasonic Flowmeter Applications

More information

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. Level Transmitter / Controller / Indicator 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. 2.1 NEW Class 1, Division 1 Hazardous Areas Approved

More information

COOLANT WASTE MINIMIZATION USING A COALESCING PLATE SEPARATOR

COOLANT WASTE MINIMIZATION USING A COALESCING PLATE SEPARATOR COOLANT WASTE MINIMIZATION USING A COALESCING PLATE SEPARATOR Kirby S. Mohr, P.E. Mohr Separations Research, Inc. 1278 FM 407 Suite 109 Lewisville, TX 75077 Phone: 918-299-9290 Cell: 918-269-8710 Dennis

More information

Nontraditional Machining Techniques

Nontraditional Machining Techniques Chapter 28 Nontraditional Machining Techniques LEARNING OBJECTIVES After studying this chapter, students will be able to: Describe several nontraditional machining techniques. Explain how nontraditional

More information

spy pig Tracking systems

spy pig Tracking systems spy pig Tracking systems Spy pig Transmitters For the most reliable signal available, the SPY Pig Transmitter uses low frequency signals to effectively and consistently penetrate a steel pipe wall. We

More information

By Pierre Olivier, Vice President, Engineering and Manufacturing, LeddarTech Inc.

By Pierre Olivier, Vice President, Engineering and Manufacturing, LeddarTech Inc. Leddar optical time-of-flight sensing technology, originally discovered by the National Optics Institute (INO) in Quebec City and developed and commercialized by LeddarTech, is a unique LiDAR technology

More information

Wave Review Questions Updated

Wave Review Questions Updated Name: Date: 1. Which type of wave requires a material medium through which to travel? 5. Which characteristic is the same for every color of light in a vacuum? A. radio wave B. microwave C. light wave

More information

A HILBERT TRANSFORM BASED RECEIVER POST PROCESSOR

A HILBERT TRANSFORM BASED RECEIVER POST PROCESSOR A HILBERT TRANSFORM BASED RECEIVER POST PROCESSOR 1991 Antenna Measurement Techniques Association Conference D. Slater Nearfield Systems Inc. 1330 E. 223 rd Street Bldg. 524 Carson, CA 90745 310-518-4277

More information

Possible installation effects on density meter in a fast loop sampling system.

Possible installation effects on density meter in a fast loop sampling system. Possible installation effects on density meter in a fast loop sampling system. Skule E. Smørgrav, TechnipFMC, FMC Kongsberg Metering AS Nils Petter Aarstad, TechnipFMC, FMC Kongsberg Metering AS Steve

More information

RECOMMENDATION ITU-R SA.364-5* PREFERRED FREQUENCIES AND BANDWIDTHS FOR MANNED AND UNMANNED NEAR-EARTH RESEARCH SATELLITES (Question 132/7)

RECOMMENDATION ITU-R SA.364-5* PREFERRED FREQUENCIES AND BANDWIDTHS FOR MANNED AND UNMANNED NEAR-EARTH RESEARCH SATELLITES (Question 132/7) Rec. ITU-R SA.364-5 1 RECOMMENDATION ITU-R SA.364-5* PREFERRED FREQUENCIES AND BANDWIDTHS FOR MANNED AND UNMANNED NEAR-EARTH RESEARCH SATELLITES (Question 132/7) Rec. ITU-R SA.364-5 (1963-1966-1970-1978-1986-1992)

More information

CLAMP-ON ULTRASONIC FLOW METER APPLICATION AND PERFORMANCE. William E. Frasier (CMSI: Retired) & Joseph H. Nettleton

CLAMP-ON ULTRASONIC FLOW METER APPLICATION AND PERFORMANCE. William E. Frasier (CMSI: Retired) & Joseph H. Nettleton CLAMP-ON ULTRASONIC FLOW METER APPLICATION AND PERFORMANCE William E. Frasier (CMSI: Retired) & Joseph H. Nettleton R T Technical Solutions 4484 Hodgson Rd Nederland, TX 77627 This paper is directed to

More information

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Presented to valued clients attending the Technology Summit hosted by: Kendall Group/ J.O.Galloup +GF+ Offering Level Measurement Continuous

More information

Active microwave moisture sensors advanced solutions for the pulp and paper industry

Active microwave moisture sensors advanced solutions for the pulp and paper industry Active microwave moisture sensors advanced solutions for the pulp and paper industry AMS an integrated system of sensors installed in various phases of the pulp and paper manufacturing process to measure

More information