ECM HIGH EFFICIENCY CIRCULATORS

Size: px
Start display at page:

Download "ECM HIGH EFFICIENCY CIRCULATORS"

Transcription

1 ECM HIGH EFFICIENCY CIRCULATORS WILO STRATOS

2 Stratos Commercial high efficiency pumpp Main features & benefits Gal/min flow 3 40 ft head 8 models (1.25, 1.5, 2 & 3 ) EC motor (permanent magnet rotor) Automatically ti adjusts to system demands d No external sensors required Easy setup via red button Water temperature from 14⁰F to 230⁰F Constant t pressure control mode Variable pressure control mode Temperature control mode BMS options: LON & Bacnet, 0-10V Infrared device for remote control & setup Excellent warranty 24/18 months UNIQUE FEATURES & UP TO 80% Q ENERGY SAVINGS!

3 Stratos-D (dual-power head pump) p) 2 & 3 size models Flow up to 450 gpm IF modules required Duty/Standby mode Lead/Lag mode Space saving Accessories saving

4 Sratos-Z for Domestic Hot Water Cast S. Steel volute EC Motor Built-in VFD T⁰ control with 0-10V IF NSF/ANSI 61-G certified pump

5 ECM Technology Commutation (reverse currents) Coil 1 Coil 4 Coil 2 Coil 3

6 Speed Control Electronic continuous speed control (Constant Pressure) > Automatic differential e pressure e control o n max 1. The brain determined the actual pumping head. (actual value) Pumping Head H [F Ft] H 2 H Constant speed pump 1 2. The drive sees the difference between the set value (point 1) and the actual value. (point 2) 3. Via ECM smart technology the controller reduces the speed and reduced the pumping head to match the system curve. (point 3) Q 1 Q 2 Flow Q [USGPM]

7 Built In Control Modes P C C (Constant Pressure Differential) Control Mode On site setting via red button Can be adjusted from 3ft to max pump head Pump will vary the flow but keep a constant diff. pressure Built-in control mode, does not require external sensors Recommended in low resistance systems or in-floor heating loops zoning In the example above, the pump is set to maintain 20 ft constant differential pressure. The flow will modulate from 0 to 230 gpm.

8 Built In Control Modes Constant Speed Control Mode Max Set speed 2210 rpm Min On site setting via red button Can be adjusted from Min to Max speed with 10 rpm increments Built-in control mode, does not require external sensors Recommended in fixed flow/head application In the example above, the pump is set to 2210 rpm. Minimum and Maximum speeds vary depending on pumps models.

9 Built In Control Modes P V (Variable Pressure Differential) Control Mode On site setting via red button Can be adjusted from 3ft to max pump head Pump will automatically vary the flow and the head on system demand. Min head at 0 flow is half the max head set Built-in model, does not require external sensors Recommended in high resistance systems In the example above, the pump is set to maintain 24 ft differential pressure at maximum flow. As the flow decreases, the head decreases proportionally.

10 Built In Control Modes P T T (Temperature Pressure Differential) Control Mode Change in temperature at the pump changes the pressure setpoint IR tool required to activate and set perameters Stratos t installed on return T Max T Min = > or = 50 deg. F T Max: 150 F Max T: 10 T Max: 190 F Max T: 7 T Min: 100 F Max T: 30 T Min: 140 F Max T: 25 Head Head F 150 F Temp 190 F 140 F Temp Condensing Boiler Application Non-Condensing Boiler Application (Decreases delta P on temp rise) (Increases delta P on temp rise)

11 Power Supply 1ph 230V G FC 2 x 1ph 115V Check local electrical code 3ph 208/230V Acceptable input voltage: 195V min / 263V max

12 Interface modules for BMS communication

13 External Control Modes BUILDING MANAGEMENT SYSTEM Interface modules for: 0-10V DC Signal LON BACNET Dual pump operation

14 Inter-Face 0-10V/DP / Ext. Off 0 to 1 V: Pump Off 1 to 3V: Pump On / Minimum speed 3 to 10V: Speed modulation, 3V=Min and 10V-Max Ext. Off Contact: if closed losed = Pump On / if open = Pump Off

15 Inter-Face 0-10V/DP/Ext. Min 0 to 1 V: Pump On / Minimum speed 1 to 10V: Speed modulation, 1V=Min and 10V=Max Ext. Min Contact: if closed = Modulation / if open = Speed Min

16 Inter-Face 0-10V/DP/SBM 0 to 1 V: Pump Off 1 to 3V: Pump On / Minimum speed 3 to 10V: Speed modulation, 3V=Min and 10V-Max SBM Status Contact: if closed = Pump is On / if open = Pump is Off

17 Dual Pump Operation Dual pump operation Auto changeover Lead/Lag mode Duty/Standby mode Power Management

18 BACnet InterFace Module MS/TP SLAVE IF RS485 High Baud Rates Analog input/output Binary input/output Multistate input/output p Dual pump operation

19 LON InterFace Module FTT 10A transceiver High Baud Rates Analog input/output Binary input/output Multistate input/output XIF files available Dual pump operation

20 Interface (IF) modules for Stratos IF modules summary board Description Article # 0 10V Ext. Off Ext. Min Run (SBM) LON BacNet DP IF 0 10V/DP/Ext.Off x x x IF 0 10V/DP/Ext.Min x x x IF 0 10V/DP/SBM x x x IF SBM/Ext.Off/DP x x x IF LON x x IF BacNet x x Key: x = Available 0 10V = External 0 10V DC input signal Ext. Off = pump p start/stop contact Ext. Min = Default minimum speed contact SBM = Run status contact LON = BMS LON interface BacNet = BMS BacNet interface DP = Dual pump management

21 IR Remote Control Infra-Red remote control: O it i ti i On site communication via laptop Control setting Pump monitoring Data logging & saving

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE BACnet Enabled Description The FCU-503 is designed to provide complete control of fan coil units and / or underfloor heating circuits. The FCU-5 incorporates

More information

FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE

FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE BACnet Enabled Description The FCU-501 is designed to provide complete control of fan coil units and / or underfloor heating circuits. The FCU-5 incorporates

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N All rights reserved. The contents provided herein must

More information

ELECTRONIC THERMOSTAT: T920

ELECTRONIC THERMOSTAT: T920 μnistδt ELECTRONIC THERMOSTAT: T One analog output DESCRIPTION The T series thermostats are microcomputer-based, proportional and integral (PI) devices with one analog 0 to 0 output. They can be used with

More information

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault CCE-32 1.09 Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault Index 1. General description... 5 2. Applications... 5 3. Installation... 5 4. Connections...

More information

Submittal Packages Detailed with Items and Reviewers

Submittal Packages Detailed with Items and Reviewers Submittal Packages Detailed with Items and Reviewers Tenochca Upgrades Project # 1 San Diego State University 00 Campanile Drive San Diego, CA 918 Tel: 619-94-740 Fax: 0079-1116-0 Circulating Pump Author

More information

BAS Integration Manual

BAS Integration Manual Snow Melting Control 680 Introduction BAS Integration Manual Snow Melting 680_B 10/15 Replaces: 04/15 The Snow Melting Control 680 can communicate with a Building Automation System (BAS) using either BACnet

More information

BACnet- MS/TP COMMUNICATION V

BACnet- MS/TP COMMUNICATION V - MS/TP COMMUNICATION V1.00.08.17 11.1 Introduction The VFD can be controlled and monitored through the BACnet MS/TP protocol over an RS-485 connection. The VFD operates as an MS/TP master device, which

More information

Cetetherm IQ Heat Midi/Maxi

Cetetherm IQ Heat Midi/Maxi Cetetherm IQ Heat Midi/Maxi Preconfigured DDC solution for Midi and Maxi. Ready to plug-in. Built in web pages for remote control. Quick feedback during alarms and deviations. No licens or extra programs

More information

University of Rochester Design Standard August 13, 2014

University of Rochester Design Standard August 13, 2014 University of Rochester Design Standard August 13, 2014 330000-Utility Metering Standard 1) General a) Project Engineer of Record shall submit peak building load projections to facilitate meter sizing

More information

Modbus VAV Controller Configuration Properties

Modbus VAV Controller Configuration Properties Modbus VAV Controller Configuration Properties Modbus Object Type: Holding Registers Name Default Min Max Units Modbus Reg # Multiplier Focus Screen Modbus Notes DeviceType 0 0 0 None 1 1 Device (Not writable)

More information

OCCUPANCY SENSOR REMOTE USER GUIDE

OCCUPANCY SENSOR REMOTE USER GUIDE OCCUPANCY SENSOR REMOTE USER GUIDE Use the handheld programming remote to test and adjust the settings of your occupancy sensor, which can accommodate up to six sensor parameter profiles. FSP-2X1 is the

More information

Submittal Data Sheet Wilo MVI - Vertical Multistage Pumps

Submittal Data Sheet Wilo MVI - Vertical Multistage Pumps Wilo MVI Project: Engineer: Contractor: Submitted By: Date: Approved By: Date: Tag # Model # Flow Head HP Cycle Phase Voltage RPM Hz H [ft] ηp [%] P [hp] 7 7.......7..9.......................... MVI -

More information

Calio SI First and only circulator designed and produced in Turkey

Calio SI First and only circulator designed and produced in Turkey Our technology. Your success. Pumps n Valves n Service Calio SI First and only circulator designed and produced in Turkey 02 Introduction Made in Turkey: Save costs with Calio SI and KSB KSB offers you

More information

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't Think About Control Fundamentals Training Terminology Control Eko Harsono eko.harsononus@gmail.com; 1 Contents Topics: Slide No: Advance Control Loop 3-10 Control Algorithm 11-25 Control System 26-32 Exercise

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives 3.0 50HP @ 200 to 240V AC 3.0 350HP @ 380 to 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum

More information

DeltaSol MX. Certifi ed for the North American market! CONTROL TECHNOLOGY. incl.

DeltaSol MX. Certifi ed for the North American market! CONTROL TECHNOLOGY. incl. DeltaSol MX CONTROL TECHNOLOGY incl. The all-rounder HE pump control Certifi ed for the North American market! The clcus certification confirms that the controller is certified to UL 60730-2-9 and CSA

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

APPLICATION GUIDE Delta Network Sensor Thermostat: BACstat II DNS-24, DNT-T103, & DNT-T221 Document Edition 3.1

APPLICATION GUIDE Delta Network Sensor Thermostat: BACstat II DNS-24, DNT-T103, & DNT-T221 Document Edition 3.1 APPLICATION GUIDE Delta Network Sensor Thermostat: BACstat II DNS-24, DNT-T103, & DNT-T221 Document Edition 3.1 Product Description The BACstat II is an intelligent 4-button room sensor/thermostat with

More information

Sauter Components

Sauter Components R 44.488/ QRK 0: Heating controller Used in conjunction with temperature detectors (Ni000) and appropriate control valves for heating and domestic-hot-water control (with various configurations), mainly

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VT8300 Series Installation Guide 24 Vac Low Voltage

VT8300 Series Installation Guide 24 Vac Low Voltage VT00 Series Installation Guide Low Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation Terminal Identification & Function Terminal identification Wiring Typical Applications

More information

Variable Frequency Drives

Variable Frequency Drives Table of Contents Variable Frequency Drives Product Product Code Resource Documents Page # Introduction F-3 SED2 154-042 F-5 with Conventional Bypass Option SED2 154-044 F-9 with Electronic (E) Bypass

More information

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification General The VT76x7 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop

More information

TC 204 Heating Controller

TC 204 Heating Controller TC 204 Heating Controller ver. 1.32-01 The TC204 is a multi-purpose heating controller with built-in programs for different types of heating systems. General Data Power requirement 24 volts ac, 2 va Inputs

More information

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement BACnet Protocol Implementation Conformance Statement Date: 2012-06-27 Vendor Name: Trane Product Name: Trane TR150 Product Model Number: TR150 Applications Software Version: 3.0 Firmware Revision: 3.0

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

ECB-103 BACnet B-ASC 10-Point Programmable Controllers D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,

More information

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units 1 Time Scheduling RDU-4/TS - Description of Control Operation The temperature control and time scheduling for the building space is

More information

About AB Industrietechnik

About AB Industrietechnik About AB Industrietechnik AB Industrietechnik Srl has been manufacturing for over 30 years control equipment and measuring instruments for all the measurable parameters in the field of thermo technical

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

DC CIRCUITS Part I of III Parts. Part II installation. Part III troubleshooting

DC CIRCUITS Part I of III Parts. Part II installation. Part III troubleshooting DC CIRCUITS Part I of III Parts Part II installation Part III troubleshooting Trane ComfortSite is a user-friendly Internet site designed to save you time and it s FREE for Trane Customers. Order Equipment,

More information

CONTROL MANUAL. Dry-Pic 09PE - 09VE

CONTROL MANUAL. Dry-Pic 09PE - 09VE CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth

More information

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual ADAM-422T Serial Base Dual Loops PID Controller User s Manual Warning Message : The ADAM-422T is recommended to be used in general purposed air conditioning application. When using this product in applications

More information

TLC3-BCR-U Series Thermostat

TLC3-BCR-U Series Thermostat OVERVIEW TLC3-BCR-U Series Thermostat Features Low power energy consumption: < 1W per unit Relays switching for outputs each up to 300W Temperature control for 2 or 4-pipe heating or cooling systems. Optional

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual vacon 1 TABLE OF CONTENTS Document: DPD01083A Version release date: 16.11.12 Corresponds to software package FW0159V121106.vcx 1. Vacon 100 FLOW - Quick Startup

More information

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control NEW FIRMWARE MAKES SETUP A SNAP Application based commissioning allows parameters

More information

Understanding Electronic Controls Diagrams

Understanding Electronic Controls Diagrams Understanding Electronic Controls Diagrams 1 DC Circuit Rules 2 Inputs VS outputs Micro processors 3 Troubleshooting Tools Jumper Wires Circuit Breaker Diode 50 KΩ potentiometer 500 Ω Resistor 9 VDC battery

More information

Adjustable Frequency Drive Fundamentals By Rick Porembski Of The Sandberg Div. of Bornquist.

Adjustable Frequency Drive Fundamentals By Rick Porembski Of The Sandberg Div. of Bornquist. Adjustable Frequency Drive Fundamentals By Rick Porembski Of. Why do we want to do variable speed pumping? Flow Control HVAC systems are designed for worst case situations. Most of the time they have excess

More information

VARIABLE FREQUENCY DRIVE SPECIFICATION

VARIABLE FREQUENCY DRIVE SPECIFICATION VARIABLE FREQUENCY DRIVE SPECIFICATION 1.0. SUMMARY The use of variable frequency drives (VFDs) in conjunction with wastewater lift stations has been identified as a means improve efficiency and to moderate

More information

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1 INSTRUCTION MANUAL ADAQCPC R1 AQUAVAR CPC Modbus Communications (Software Version 204 and later)* ADDENDUM TO THE INSTALLATION AND OPERATION MANUAL (IM167) * Aquavar CPC units with software 204 and later

More information

BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665

BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665 BACnet PTEC Controller Dual Duct 2 AVS - Constant Volume with Two Inlet Sensors and Optional Reheat, Application 6665 Application Note 140-1113 Building Technologies Table of Contents Overview... 5 BACnet...

More information

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs. Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Analog and Start/Stop Outputs SENSORS Document Part Number: 550996 Revision E Data Sheet FEATURES Linear, Absolute Measurement

More information

Troubleshooting Guide for Aquatrac Smart AS and Flex

Troubleshooting Guide for Aquatrac Smart AS and Flex Troubleshooting Guide for Aquatrac Smart AS and Flex Part 1 Sensors and Analog Signals Alpha Release July 28 th, 2000 Alpha Release Page 1 of 21 Preface Welcome to the Aquatrac troubleshooting guide. This

More information

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement BACnet Protocol Implementation Conformance Statement Date: October 06, 2009 Vendor Name: Schneider Electric Product Name: Low Voltage AC Motor Drive Product Model Number: Altivar 61 Application Software

More information

Electronic pressure-independent characterised control valve with energy monitoring

Electronic pressure-independent characterised control valve with energy monitoring Protocol Implementation Conformance Statement Energy Valve Electronic pressure-independent characterised control valve with energy monitoring Contents Protocol Implementation Conformance Statement - PICS

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

Installation Guide. ECL Comfort 310, application A Table of Contents

Installation Guide. ECL Comfort 310, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 5 2.1 Before you start.....................................................

More information

E l e c t r o m a g n e t i c f l o w m e t e r s

E l e c t r o m a g n e t i c f l o w m e t e r s E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without

More information

SE7000 Series Application guide

SE7000 Series Application guide SE7000 Series Application guide Control Performance Energy savings Better building management About Schneider Electric As a global specialist in energy management with operations in more than 100 countries,

More information

CONTENTS Project name WMHpc Revision 1.3

CONTENTS Project name WMHpc Revision 1.3 , modbus protocol, Modbus protocol (rev 1).doc 1/20 CONTENTS 1 MODBUS protocol and parameters... 2 1.1 Implementation... 2 1.2 Commands... 3 Parameters...5 2 MODBUS virtual memory map... 6 2.1 Bit addressing

More information

Universal Controller

Universal Controller Universal Controller Overview and Configuration Manual Overview... 1 About this Manual... 1 Introduction... 5 Hardware Overview... 5 Software Overview... 7 Interpreting Flow Diagrams... 8 Foreign Language

More information

Application Note CTAN #287

Application Note CTAN #287 Application Note CTAN #287 This Application Note is pertinent to the Commander SK Water Pressure PID Loop Control This application note will describe a way to utilize the Commander SK (note that the Unidrive

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

1-2 VOLTS PER HERTZ CHARACTERISTICS EXERCISE OBJECTIVE

1-2 VOLTS PER HERTZ CHARACTERISTICS EXERCISE OBJECTIVE 1-2 VOLTS PER HERTZ CHARACTERISTICS EXERCISE OBJECTIVE Set the rotation direction of the motor. Understand the V/f (volts per hertz) characteristics. Learn how to use an analog voltage to assign the frequency

More information

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr.

More information

FPS. FPS Flexible Position Sensor. Function description. Your advantages and benefits

FPS.  FPS Flexible Position Sensor. Function description. Your advantages and benefits FPS www.comoso.com Accessories Sensor System FPS Flexible Position Sensor FPS Flexible Position Sensor The optional FPS sensor system measures the position of gripper jaws. It then indicates in which of

More information

TI25 - Pre-Instructional Survey

TI25 - Pre-Instructional Survey TI25 - Pre-Instructional Survey Name: Date: 1. Scheduled maintenance that is planned, with materials on hand, personnel on site, and production planning advised is called maintenance. a. predictive b.

More information

Modbus Integration Integration for Modbus Functionality for VT8300 Series

Modbus Integration Integration for Modbus Functionality for VT8300 Series Modbus Integration Integration for Modbus Functionality for VT8300 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

Metasys Zoning Package Commissioning

Metasys Zoning Package Commissioning Technical Bulletin Issue Date 11/01/01 TECHNICAL BULLETIN Metasys Zoning Package Commissioning Metasys Zoning Package Commissioning...2 Introduction... 2 Key Concepts... 3 HVAC PRO Software...3 Configuration

More information

Worcester Controls PB SMART PRODUCTS

Worcester Controls PB SMART PRODUCTS PB 935-5 SMART PRODUCTS SMART POSITIONER An Electronic Positioner with a Built-in Microcontroller For precise process control The DataFlo P Positioner, controlled by a 4-20 ma analog signal from a PLC

More information

Introduction to BLDC Motor Control Using Freescale MCU. Tom Wang Segment Biz. Dev. Manager Avnet Electronics Marketing Asia

Introduction to BLDC Motor Control Using Freescale MCU. Tom Wang Segment Biz. Dev. Manager Avnet Electronics Marketing Asia Introduction to BLDC Motor Control Using Freescale MCU Tom Wang Segment Biz. Dev. Manager Avnet Electronics Marketing Asia Agenda Introduction to Brushless DC Motors Motor Electrical and Mechanical Model

More information

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide Room Controllers Terminal Equipment Controller with Optional PIR sensor Installation Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications 1 CONTENTS Installation 2 Location 2 Installation 2 Terminal,

More information

AEROCONNECT 1B NA C Control manual

AEROCONNECT 1B NA C Control manual AEROCONNECT 1B NA 11.3 C 03-01 Control manual EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth 1. Sensor connections 1.6 Communication

More information

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller Version 10 2 HMI Display The User HMI is configurable and allows display functions such as Date, Time, Outdoor

More information

BandMaster V Manual. Installation

BandMaster V Manual. Installation BandMaster V Manual Installation Installing and configuring the BM-5 BandMaster V is a simple process. All the configuration process is done from the front panel. Installation and configuration steps are

More information

REH FC-BMS3 Modbus Manual

REH FC-BMS3 Modbus Manual 67404 02-15 (HKT) REH FC-BMS3 Modbus Manual REH FC-BMS3 REH TA3 REH TD3 REH DT3 REH CT3 www.rehau.uk Modbus registers for REH FC-BMS3 software Version 5.0 and up Modbus SLAVE communication settings: 38.4

More information

Electronic pressure-independent characterised control valve with energy monitoring

Electronic pressure-independent characterised control valve with energy monitoring Protocol Implementation Conformance Statement Energy Valve Electronic pressure-independent characterised control valve with energy monitoring Contents Protocol Implementation Conformance Statement - PICS

More information

MODEL G0632Z 16" X 42" VARIABLE- SPEED WOOD LATHE MANUAL INSERT

MODEL G0632Z 16 X 42 VARIABLE- SPEED WOOD LATHE MANUAL INSERT MODEL G0632Z 16" X 42" VARIABLE- SPEED WOOD LATHE MANUAL INSERT The Model G0632Z is the same machine as the Model G0632 except it has a higher full-load current rating, a different inverter and inverter

More information

Building Intelligence

Building Intelligence Building Intelligence WORLDWIDE. Inside every building is the potential to reduce energy costs and become more profitable. Walker Wireless helps building owners realize that potential with wireless control

More information

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3 Sensor Sensor BACnet PICS 22DTH-..6.. Duct sensor humidity / temperature 22UTH-..60X Outdoor sensor humidity / temperature 22DTM-..6 Duct sensor CO2 / humidity / temperature Contents 1. Operating elements

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass

More information

Optidrive Applications Support Library

Optidrive Applications Support Library Optidrive Applications Support Library Application Note Title AN-ODE-2-032 Related Products Optidrive E2 Overview Level 2 PI Closed Loop Feedback Control Applications 1 Fundamental - No previous experience

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for Simplified Chinese, English, French, German

More information

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration) External Sensor VOLTAGE DT140 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-10V ±0.05V ±3% (before calibration) 3MΩ 2 calibration points ±30V ACCESSORIES User Guide for MicroLog

More information

Installation, Programming Operation, & Maintenance Manual V

Installation, Programming Operation, & Maintenance Manual V Base Drive, Bypass Drive, Drive with Disconnect 200~480V (3~28A) Q-Link Manual Fan & Pump Optimized Variable Frequency Drive Installation, Programming Operation, & Maintenance Manual V2.00.09.17 CAUTION,

More information

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration) External Sensor CURRENT DT139 Range: Resolution: Accuracy: Input impedance: Calibration: OV protection: 0-20mA ±0.1mA ±3% (before calibration) ~170Ω 2 calibration points ±55mA ACCESSORIES User Guide for

More information

W I R E L E S S L I N E C A R D

W I R E L E S S L I N E C A R D WIRELESS LINECARD WIRELESS ACI s wireless product line is based on MESHNET 900 TM MHz Spread Spectrum Mesh Network Technology. It provides the HVAC Industry a much needed option for a proven, reliable,

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Control solutions Biofloor

Control solutions Biofloor MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital

More information

Touch-Plate BACnet Catalog

Touch-Plate BACnet Catalog Touch-Plate Table Of Contents Touch-Plate BACnet Stations..... Touch-Plate BACnet Sensors.... Touch-Plate BACnet Relay Panels...... Touch-Plate Nexus BACnet Controller...... 0 Wayne Trace Fort Wayne, Indiana

More information

BOILER MANAGEMENT SYSTEM

BOILER MANAGEMENT SYSTEM BOILER MANAGEMENT SYSTEM g y ( ) Table of Contents Page SECTION 1 ABOUT YOUR NEW BOILER MANAGEMENT SYSTEM (BMS) 1-1 SECTION 2 FEATURES OF THE BMS 2-1 SECTION 3 INSTALLING THE BMS 3-1 3.1 MOUNTING THE BMS

More information

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER Honeywell RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER W7620 Zone Controller Water Source Heat Pump - -.> The W7620 Zone Controller provides customized control of HVAC zone equipment.

More information

Introduction to BAS Technology

Introduction to BAS Technology Introduction to BAS Technology Dave Kahn, P.E. Why Back to basics? Sometimes you get what you ask for resulting in: The perfect job OR Unhappy owners & occupants Unexpected network limitations Product

More information

VFD 101 Lesson 1. Functions of an Variable Frequency Drive (VFD)

VFD 101 Lesson 1. Functions of an Variable Frequency Drive (VFD) VFD 101 Lesson 1 Functions of an Variable Frequency Drive (VFD) This lesson covers the basic functions of a Variable Frequency Drive (VFD) as it applies to fans. 10/2/2003 Here is the basics outline for

More information

A Super trainer with advanced hardware and software features only found in very expensive equipment.

A Super trainer with advanced hardware and software features only found in very expensive equipment. PLC Trainer PTS T100 LAB EXPERIMENTS A Super trainer with advanced hardware and software features only found in very expensive equipment. You won t find any similar equipment among our competitors at such

More information

RE92. CHECKMATE. Dual loop controller for industry purpose.

RE92. CHECKMATE. Dual loop controller for industry purpose. ! " # $ % & & ( ) * +. 0 1 2 3 4 5 8 9 6 : 7 ; * < + = >? @. A B C 0 D 1 E F G H 2 D I J 3? RE92. CHECKMATE. Dual loop controller for industry purpose. Simple and userfriendly service Safety and reliability

More information

SITRANS L Level instruments

SITRANS L Level instruments SITRANS L Level instruments /2 Point level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Electro-mechanical switches

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering

More information

BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682

BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682 BACnet PTEC Controller VAV with CO2 Monitoring, Parallel Fan and AOV or Floating Point Heating, Application 6682 Application Note 140-1156 Building Technologies Table of contents Overview... 5 BACnet...

More information

Plug & Play. No Calibration Required

Plug & Play. No Calibration Required No Calibration Required Plug & Play No K-actor Programming Read the User's Manual Carefully before Starting to Use the Unit. All TK Series low Meters are actory Calibrated. Manufacturer reserves the right

More information

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only. This document is a short guide to how to connect, do the configuration and start the unit in the easiest way. Refer to the Instruction Manual IMAE-01, appropriate revision of Axpert-Eazy Series AC Drive

More information

Heat Exchanger Construction Checklist

Heat Exchanger Construction Checklist Heat Exchanger Checklist Project: Pump tag: Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing. The checklist

More information

GPS-G5 User s Manual

GPS-G5 User s Manual GPS-G5 User s Manual Contents Using the GPS... 1 Description...1 Electrical Connections...2 Mounting...3 GPS Configuration...3 GPS Operation...3 Logging Device Configuration...4 Data Analysis...5 Specifications...

More information

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6 CHAPTER KEYPAD OPERATION 3 AND QUICKSTART In This Chapter... The GS2 Digital Keypad.....................3 2 LED Display.........................................3 2 LED Indicators.......................................3

More information

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT. MODBUS/BECO2200-M3425A Communication Data Base for M-3425A Integrated Protection System Device I.D. = 150 Specifications presented herein are thought to be accurate at the time of publication but are subject

More information

Experiment#6: Speaker Control

Experiment#6: Speaker Control Experiment#6: Speaker Control I. Objectives 1. Describe the operation of the driving circuit for SP1 speaker. II. Circuit Description The circuit of speaker and driver is shown in figure# 1 below. The

More information

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K

POSICHRON position sensor in a stainless steel pressure tube. Protection class IP68/IP69K Round Profile Housing with Analog POSICHRON position sensor in a stainless steel pressure tube Protection class IP68/IP69K Underwater applications, permanent pressure-proof up to 15 bar Measurement range

More information

8V General information. 2 Order data 8V

8V General information. 2 Order data 8V 8V05.00-8V05.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic

More information