Field Testing Update

Size: px
Start display at page:

Download "Field Testing Update"

Transcription

1 Field Testing Update Adrian Young Fluke Networks November, 2013 Singapore

2 Objectives for this session Copper field standards update Look at new copper field measurements Fiber field standards update

3 IEC Ed.4 Defines field tester accuracy for ISO/IEC 11801:2010 Level IIe, supports Class D (100 MHz) Level III, supports Class E (250 MHz) Level IIIe, supports Class E A (500 MHz) Level IV, supports Class F (600 MHz) Level V, supports Class F A (1,000 MHz) Status Draft, publication Q2 2014? Work can begin on 2 GHz field testing once published

4 ANSI/TIA-1152 Defines field tester accuracy for ANSI/TIA-568-C.2 Level IIe, supports Category 5e (100 MHz) Level III, supports Category 6 (250 MHz) Level IIIe, supports Category 6A (500 MHz) Status Published September 2009 Opened for review at TIA meeting in Portland (June 2013) Editor: Fluke Networks Work has begun on supporting 2 GHz field testing Other measurements to be considered Resistance, Resistance Unbalance Possible new link definition(s)

5 Resistance Unbalance Specified in IEEE 802.3af and IEEE 802.3at for the successful transmission of Power over Ethernet

6 Resistance Unbalance Difference in DC Resistance between conductors of the same pair 1.87 Ω 1.85 Ω Resistance = 3.7 Ω Resistance Unbalance = 0.02 Ω

7 Resistance Unbalance ISO/IEC 11801: Ω or 3.0% for the Permanent Link (Greater of the two) 0.20 Ω or 3.0% for the Channel (Greater of the two) Not a requirement in IEC field testing standard.yet ANSI/TIA-568-C Ω or 3.0% for the Channel (Greater of the two) Not a requirement in ANSI/TIA-1152 field testing standard yet

8 Copper Cladded Aluminum Cable Limited data from the field suggests this measurement could be used to detect the presence of such cable CCA cable is not permitted in either TIA or ISO

9 Category 8 ANSI/TIA-568-C.2-1 Support proposed for 40GBASE-T Supported Channel length now 30 m Status Working on laboratory fixtures to support 2 GHz testing Need round robin testing between labs to see if there is good correlation of measurements Test plug performance to be decided No fixture available to measure test plugs to 2 GHz Field testers Baseline accuracy demonstrated No Channel measurement accuracy demonstrated No Perm. Link accuracy demonstrated

10 Baseline accuracy ANSI/TIA-568-C.2-1 Accuracy without adapters Adapter development is the real challenge here

11 New FIELD copper measurements

12 Balance Balance is critical for successful transmission Reduces emissions Mitigates external noise sources

13 Balance Balance is critical for successful transmission Reduces emissions Mitigates external noise sources

14 Balance Defined in ANSI/TIA-568-C.2 Channel limits only for TCL and ELTCTL Not a requirement in ANSI/TIA-1152 field testing Defined in ISO/IEC 11801:2010 Channel limits for only TCL and ELTCTL Not a requirement in IEC Ed.4 (draft) field testing Industrial Ethernet group very interested

15 TCL (Transverse Conversion Loss) Transverse Conversion Loss is the ratio (in db) of a common-mode voltage measured on a wire pair relative to a differential-mode voltage applied to the same end of the pair. The TCL value shows you how well the impedances of the pair s conductors are balanced.

16 TCL (Transverse Conversion Loss) A high TCL value means that the impedances of the conductors relative to ground are almost equal. High TCL values correspond to better noise immunity and lower emissions.

17 TCTL (Transverse Conversion Transfer Loss) Transverse Conversion Transfer Loss is the ratio (in db) of a common-mode voltage measured at the far end of a wire pair relative to a differential-mode voltage applied to the near end of the same pair. TCTL values improve with longer links We actually use Equal Level Transverse Conversion Loss (ELTCTL)

18 ELTCTL (Equal Level Transverse Conversion Transfer Loss) Subtracting the effects of insertion loss normalizes the results for length and produces ELTCTL values, which are not dependent on length. Because ELTCTL does not depend on length, it is used instead of TCTL to evaluate cable performance. High ELTCTL values correspond to better noise immunity and lower emissions.

19 Shield integrity ALL wire mappers would think the shield was connected Grounding of two racks makes this happen Poor shielded terminations can result in poor Alien Crosstalk

20 Shield integrity An incorrectly terminated shield can adversely affect transmission properties such as Alien Crosstalk The data below was taken from a data center where the shield was terminated incorrectly Better Worse The traditional Wire Map passed the shield shield

21 New Wire Map approach Shield Integrity Use a Time Domain Reflectometer test to see if the shield is truly connected by applying a differential signal between the shield and all four pairs

22 Shield integrity Even when the two connectors are grounded together

23 Shield integrity Traditional Wire Mappers will show this connected

24 Modified Single Connector Permanent Link IP camera and Wireless Access Point links are often terminated with an RJ45 plug Standards participants looking to define this link definition which is already found in BICSI but no test guidelines are given

25 Modified Single Connector Permanent Link Recommended method at this time is to use a Permanent Link Adapter at one end and a Channel Adapter at the other Use Permanent Link test limits Channel Adapter Remote RJ45 plug excluded from measurement Perm. Link Adapter

26 Modified Single Connector Permanent Link Using time domain techniques, it is possible to see if the RJ45 plug is bad but there is no standard to support this

27 Fiber Standards Update

28 ISO/IEC (2006) This standard us under review Two methods to measuring a Permanent Link 1 Jumper reference Accepted as the measurement with the least uncertainty 3 Jumper reference Required for legacy test equipment that has fixed input ports Users often end up with negative loss readings Negative loss readings rejected for warranty application Measurement uncertainty in the field is unacceptable Too many negative loss readings! There was a proposal to a variation of the 3 Jumper Reference but it was rejected over concerns of a change in reference planes

29 ANSI/TIA B Title: Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant Localized changes being made to only require Encircled Flux for OM3/OM4 installations Was talk of bring back Coupled Power Ratio (Rejected) Coupled Power Ratio has a measurement uncertainty of 40% Use of expensive and difficult to get hold of launch conditioners driving this change Still recommends Encircled Flux compliant sources for other multimode fibre types

30 ANSI/TIA B No option to use a Vertical Cavity Surface Emitting Laser (VCSEL) as a source, previous A did allow them VCSELs have a spectral width 0.47 nm Measurement uncertainty associated with VCSELs is unacceptable with todays low loss components Cabling vendors rejecting these results too

31 ANSI/TIA C (In progress) ANSI/TIA B = Adoption of IEC ANSI/TIA C = Adaptation of IEC ANSI/TIA C Make 50 µm 850 nm normative for Encircled Flux All other cases informative for Encircled Flux Proposal for HOML for informative cases accepted HOML = Higher Order Modal Loss Experiments by FNET proved concept Produces a field verification method that anyone could do Not a substitute for Encircled Flux 20% confidence factor

32 HOML Procedure Dual wavelength light source 50 µm or 62.5 µm TRC P 0 STEP 1: HOML with TRC, 50 µm or 62.5 µm versions Dual wavelength light source 50 µm or 62.5 µm TRC 5 Turn, 17 mm/22 mm P 1 STEP 2: HOML with simple 5-turn mandrel, 50 µm or 62.5 µm versions HOML is the difference in power comparing 0 turns with 5 turns (P 0 -P 1 ) 32

33 TIA-TSB-4979 Title: Practical Considerations for Implementation of Multimode Launch Conditions in the Field Gives two options on being Encircled Flux compliant Use a launch conditioner User a test cord tuned to an Encircled Flux compliant source Encircled Flux compliant sources reduce measurement uncertainty due to launch conditions from 40%* to 10% * Some experts are suggesting this is closer to 60% based on their testing

34 TIA-TSB-4979 Method 1: Launch Conditioner Makes any LED source Encircled Flux compliant User complain of bulkiness Cost concerns Can be difficult to get hold of

35 TIA-TSB-4979 Method 2: Matched source and test reference cord EF EF Tester vendor specific More elegant Significantly cheaper

36 Is EF needed? Yes Data Centres are multi-connector environments The use of low loss components is required If the consultant or cabling vendor specifies a loss budget (limit) based on these numbers, you may not achieve it with a non EF solution

37 Available online BICSI News

38 Questions? Thank you for your time

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need

More information

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems. Optical loss testing in the field is not as simple as it seems. Abstract Optical Fiber Loss Testing Optical loss testing of multimode fiber can be affected by many variables, including fiber mismatch,

More information

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling David Mazzarese, Technical Manager, Fiber Systems and Standards Engineering, OFS Learning

More information

Multimode Fiber Characterization Encircled Flux & Launch Condition Considerations

Multimode Fiber Characterization Encircled Flux & Launch Condition Considerations Application Note Multimode Fiber Characterization Encircled Flux & Launch Condition Considerations Introduction Current communication data rates in local networks range from 10/100 Mbps for Ethernet to

More information

Level III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail

Level III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail Level III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail 1 Outline Henriecus Koeman Fluke Networks July 9, 2001 This rather technical discussion contains

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61935-1 Edition 3.0 2009-07 Specification for the testing of balanced and coaxial information technology cabling Part 1: Installed balanced cabling as specified in ISO/IEC 11801

More information

Independent Testing - For End User Confidence

Independent Testing - For End User Confidence Independent Testing - For End User Confidence EVALUATION OF PERFORMANCE OF LEVEL IIIe FIELD TESTER FROM FLUKE NETWORKS, TYPE DTX-1800 CABLE ANALYZER, FOR 500 MHz PERMANENT LINK MEASUREMENTS Main Unit,

More information

WHITE PAPER INTRODUCTION DC RESISTANCE UNBALANCE TESTING: EASY, LOW-COST INSURANCE FOR YOUR POE SYSTEMS

WHITE PAPER INTRODUCTION DC RESISTANCE UNBALANCE TESTING: EASY, LOW-COST INSURANCE FOR YOUR POE SYSTEMS WHITE PAPER DC RESISTANCE UNBALANCE TESTING: EASY, LOW-COST INSURANCE FOR YOUR POE SYSTEMS INTRODUCTION Originally ratified by IEEE in 999 and 00 respectively, gigabit Ethernet (000BASE-T) and power over

More information

10-Gbit/s 850-nm VCSEL Model 1780

10-Gbit/s 850-nm VCSEL Model 1780 USER S GUIDE 10-Gbit/s 850-nm VCSEL Model 1780 Caution - Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Caution

More information

Instalaciones de fibra óptica en entornos de centros de datos y campus para suportar 40, 100g y más

Instalaciones de fibra óptica en entornos de centros de datos y campus para suportar 40, 100g y más Instalaciones de fibra óptica en entornos de centros de datos y campus para suportar 40, 100g y más Jim Davis Regional Marketing Engineer Fluke Networks Agenda Where is the technology today 10 G per Wavelength

More information

25-Gbit/s, 850-nm VCSEL

25-Gbit/s, 850-nm VCSEL USER S GUIDE 25-Gbit/s, 850-nm VCSEL Model 1784 Caution Use of controls or adjustments or performance procedures other than those specified herein may result in hazardous radiation exposure Caution The

More information

Migration to 50/125 µm in the Local Area Network

Migration to 50/125 µm in the Local Area Network Migration to 50/125 µm in the Local Area Network By Doug Coleman Introduction Enterprise local area networks (LAN) should be designed to support legacy applications as well as emerging high-data-rate applications.

More information

Data sheet C6 A RJ45 field plug pro

Data sheet C6 A RJ45 field plug pro Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems Originally ratified by IEEE in 1999 and 2003 respectively, gigabit Ethernet (1000BASE-T) and power over Ethernet

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication ISO/IEC TR 11801-9901 TECHNICAL REPORT Edition 1.0 2014-10 colour inside Information technology Generic cabling for customer premises Part 9901: Guidance for balanced cabling in support of at least 40

More information

TIA FO Task Group on Modal Dependence of Bandwidth. 7/99 Status Update

TIA FO Task Group on Modal Dependence of Bandwidth. 7/99 Status Update TIA FO-2.2.1 Task Group on Modal Dependence of Bandwidth 7/99 Status Update Michael J. Hackert Chair, TIA FO-2.2 Task Group HACKERTMJ@CORNING.COM 2.2 TG Scope Develop recommendation of system bandwidth

More information

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable variable

More information

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/ Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT ISO/IEC TR 11801-9901 Edition 1.0 2014-10 colour inside Information technology Generic cabling for customer premises Part 9901: Guidance for balanced cabling in support of at least 40

More information

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360 Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

Panduit 28 AWG Patch Cords Installation Guideline

Panduit 28 AWG Patch Cords Installation Guideline Panduit 28 AWG Installation Guideline Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure to be scalable,

More information

10GBASE-S Technical Feasibility

10GBASE-S Technical Feasibility 10GBASE-S Technical Feasibility Picolight Cielo IEEE P802.3ae Los Angeles, October 2001 Interim meeting 1 10GBASE-S Feasibility Supporters Petar Pepeljugoski, IBM Tom Lindsay, Stratos Lightwave Bob Grow,

More information

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS WHITE PAPER JULY 2017 1 Table of Contents Basic Information... 3 Link Loss Budget Analysis... 3 Singlemode vs. Multimode... 3 Dispersion vs. Attenuation...

More information

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security. Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 class E A plug to be assembled in the field and mounted in IP67 plug housings of variants 1, 4,

More information

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A RJ45 field plug pro 360 Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable

More information

Field Measurements of Return Loss

Field Measurements of Return Loss Field Measurements of Return Loss White Paper By Mark Johnston and Jim Tonti Microtest October 21, 1998 Page 1 12/15/99 Overview Return loss is an important new measurement used to qualify the performance

More information

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 class E A plug to be assembled in the field and mounted in IP67 plug housings of variants

More information

Data sheet Patch cord Cat.6 A AWG m yellow

Data sheet Patch cord Cat.6 A AWG m yellow Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch

More information

Arista 40GBASE-XSR4-AR. Part Number: 40GBASE-XSR4-AR 40GBASE-XSR4-AR OVERVIEW APPLICATIONS PRODUCT FEATURES. FluxLight, Inc

Arista 40GBASE-XSR4-AR. Part Number: 40GBASE-XSR4-AR 40GBASE-XSR4-AR OVERVIEW APPLICATIONS PRODUCT FEATURES. FluxLight, Inc Part Number: 40GBASE-XSR4-AR 40GBASE-XSR4-AR OVERVIEW The 40GBASE-XSR4-AR is a parallel 40 Gbps Quad Small Form-factor Pluggable (QSFP+) optical module. It provides increased port density and total system

More information

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification multi-port Cat.6 class E A plug compliance with class E A to ISO/IEC 11801 Ed.2.2:2011-06,

More information

Multi-fiber testing for 40G Ethernet

Multi-fiber testing for 40G Ethernet Multi-fiber testing for 40G Ethernet How do the standards look on the real job site? Aswin Babu Jagadeesan Software Engineer Softing Singapore Pte Ltd (Formerly Psiber Data Pte Ltd) Agenda Standards refresher

More information

Bending the Truth - Get the straight story about Corning ClearCurve multimode fibers

Bending the Truth - Get the straight story about Corning ClearCurve multimode fibers Bending the Truth - Get the straight story about Corning ClearCurve multimode fibers WP6372 Issued: January 211 Introduction In 29, Corning introduced ClearCurve multimode fiber, the first standards compliant

More information

XENPAK-10GB-SR XENPAK-10GBASE-SR 850nm, 300m Reach

XENPAK-10GB-SR XENPAK-10GBASE-SR 850nm, 300m Reach Features XENPAK-10GB-SR XENPAK-10GBASE-SR 850nm, 300m Reach Compatible with XENPAK MSA Rev.3.0 Support of IEEE802.3ae up to 300m (OM3 MMF) Power Consumption 1.8W (typ.) Temperature Range 0 to 70 C Vertical

More information

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling Automotive Datalinks over Twisted Quad Cabling T. Müller, G. Armbrecht, S. Kunz Rosenberger Hochfrequenztechnik GmbH & Co. KG Outline Automotive Datalinks over Twisted Quad Cabling Twisted Quad fundamentals

More information

Wavelength (nm) (m) ( o C) SPM-2100AWG 10.3 SR / SW 300 / 82 / 33* 850 VCSEL SFP+ with DMI -40 to 85 Yes

Wavelength (nm) (m) ( o C) SPM-2100AWG 10.3 SR / SW 300 / 82 / 33* 850 VCSEL SFP+ with DMI -40 to 85 Yes / SPM-2100BWG / SPM-2100AWG (RoHS Compliant) 3.3V / 850 nm / 10.3 Gb/s Digital Diagnostic SFP+ LC Multi-Mode TRANSCEIVER ********************************************************************************************************************************************************************

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS IEC 61935.1:2006 IEC 61935-1:2005 AS/NZS IEC 61935.1:2006 Australian/New Zealand Standard Testing of balanced communication cabling in accordance with ISO/IEC 11801 Part 1: Installed cabling AS/NZS

More information

Excalibur Series Mil-Dtl Optical Transponder, XAUI to 10GBase-SR Applications, Multimode, 850nM VCSELs

Excalibur Series Mil-Dtl Optical Transponder, XAUI to 10GBase-SR Applications, Multimode, 850nM VCSELs Excalibur Series Mil-Dtl-38999 Optical Transponder, XAUI to 10GBase-SR Applications, Multimode, 850nM VCSELs Dual Port, Jam Nut FEATURES Suitable for 10GBASE-SR/SRL 10G Ethernet applications @ 10.3125Gbps

More information

Data sheet C5 RJ45 field plug pro 2P PROFINET

Data sheet C5 RJ45 field plug pro 2P PROFINET Illustrations Dimensional drawing Page 1/5 See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port

More information

- Characteristic impedance of cabling links is characterised by Return Loss

- Characteristic impedance of cabling links is characterised by Return Loss ISO/IEC 11801 ISO 11801 is the principle design standard for structured cabling systems for all countries of the world that do not have more specific standards, such as ISO 11801 (European Union), TIA

More information

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs: DATA SHEET CISCO DWDM GBICS The Cisco Dense Wavelength-Division Multiplexing (DWDM) Gigabit Interface Converter (GBIC) pluggables allow enterprise companies and service providers to provide scalable and

More information

Data sheet C6 A modul K 90 jack - keystone style

Data sheet C6 A modul K 90 jack - keystone style Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: Keystone, 90 cable feed solid,

More information

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse

Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4. Frank Chang Vitesse Comment Supporting materials: The Reuse of 10GbE SRS Test for SR4/10, 40G-LR4 Frank Chang Vitesse Review 10GbE 802.3ae testing standards 10GbE optical tests and specifications divided into Transmitter;

More information

Qualification testing of 100 ohm shielded channel, Class EA. Performed for Tyco Electronics Raychem N.V.

Qualification testing of 100 ohm shielded channel, Class EA. Performed for Tyco Electronics Raychem N.V. We help ideas meet the real world DELTA Test Report DANAK TEST Reg. no. 19 Qualification testing of 100 ohm shielded channel, Class EA Performed for Tyco Electronics Raychem N.V. DANAK-19J1636 Project

More information

af-phy July 1996

af-phy July 1996 155.52 Mbps Short Wavelength Physical Layer Specification af-phy-0062.000 Technical Committee 155.52 Mbps Physical Layer Interface Specification for Short Wavelength Laser af-phy-0062.000 July 1996 1 ATM

More information

Category 7 A /Class F A Products

Category 7 A /Class F A Products CATEGORY 7 A /CLASS F A PRODUCTS Category 7 A /Class F A Products Exceeding ISO/IEC category 7 A /class F A specifications, Siemonʼs fully shielded TERA endto-end cabling solution is the highest-performing,

More information

Sentinel 3: Speed, flexibility, certainty

Sentinel 3: Speed, flexibility, certainty ]= V1.2 Sentinel 3: Speed, flexibility, certainty Sentinel 3 is the most advanced RF over fiber test and measurement system for: EMP test and EMC conformance HIRF aircraft clearance Simulated lightning

More information

Requirements for Industrial Cabling Supporting Gigabit Applications for Control, A study of Noise

Requirements for Industrial Cabling Supporting Gigabit Applications for Control, A study of Noise Requirements for Industrial Cabling Supporting Gigabit Applications for Control, A study of Noise Bob Lounsbury Principal Engineer, Rockwell Automation Rockwell Automation Presented at the ODVA 2015 Industry

More information

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver PRODUCT FEATURES Hot-pluggable XFP footprint Supports 9.95Gb/s to 10.5Gb/s bit rates Power dissipation

More information

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification multi-port Cat.6 class E A plug to be assembled in the field compliance with class E A to ISO/IEC 11801

More information

1310NM FP LASER FOR 10GBASE-LRM SC AND LC TOSA

1310NM FP LASER FOR 10GBASE-LRM SC AND LC TOSA DATA SHEET 1310NM FP LASER FOR 10GBASE-LRM SC AND LC TOSA FP-1310-10LRM-X FEATURES: 1310nm FP laser Very low power dissipation SC and LC optical receptacles 10Gbps direct modulation Impedance matching

More information

Data sheet E-DAT modul 2 port AP Cat.6 A, pearl white

Data sheet E-DAT modul 2 port AP Cat.6 A, pearl white Illustrations Dimensional drawing Wiring Page 1/7 See enlarged drawings at the end of document Product specification surface-mounted termination unit with E-DAT modul component testing for Cat.6 A to ISO/IEC

More information

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/ Page 1/9 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification modular termination unit Cat.6A, RJ45 component testing for Cat.6A to ISO/IEC 11801

More information

T Q S Q 7 4 H 9 J C A

T Q S Q 7 4 H 9 J C A Specification Quad Small Form-factor Pluggable Optical Transceiver Module 100GBASE-SR4 Ordering Information T Q S Q 7 4 H 9 J C A Model Name Voltage Category Device type Interface Temperature Distance

More information

Data sheet C6 A modul K 180 jack - Keystone style

Data sheet C6 A modul K 180 jack - Keystone style Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: Keystone, 180 cable feed solid,

More information

Independent Testing - For End User Confidence

Independent Testing - For End User Confidence Independent Testing - For End User Confidence ELECTRICAL TRANSMISSION PERFORMANCE TESTING OF SCREENED CATEGORY 6 ISO/IEC, EN & TIA/EIA CONNECTING HARDWARE ACCORDING TO REQUIREMENTS OF 2ND EDITION ISO/IEC

More information

Maverick Series Gigabit Ethernet, External TFOCA II *, 1000Base-T / SX Media Converter, 28Vdc, Multimode, 850nm

Maverick Series Gigabit Ethernet, External TFOCA II *, 1000Base-T / SX Media Converter, 28Vdc, Multimode, 850nm Maverick Series Gigabit Ethernet, External TFOCA II *, 000Base-T / SX Media Converter, 28Vdc, Multimode, 850nm Single Port, Flange Receptacles FEATURES Compliant with IEEE-802.:2005 Gigabit Ethernet Optical

More information

The fundamental differences between OM5 and OM4+ fiber

The fundamental differences between OM5 and OM4+ fiber The fundamental differences between OM5 and OM4+ fiber Pressure continues to build for data center operators to migrate to faster applications and longer link distances. In response, infrastructure OEMs

More information

[ tima-datasheet-en v11.1 ]

[ tima-datasheet-en v11.1 ] specifically designed for protection, automation and control applications in power systems 60 ns (99%) maximum time deviation single or dual 10/100Base-T Ethernet port(s) VLAN / IEEE 802.1Q support RS232

More information

QSFP, 40GBase-SR, 850nm, MM, MPO

QSFP, 40GBase-SR, 850nm, MM, MPO SO-QSFP-eSR4 QSFP, 40GBase-SR, 850nm, MM, 300m@OM3, MPO OVERVIEW The SO-QSFP-eSR4 is a parallel 40 Gbps Quad Small Form-factor Pluggable (QSFP+) optical module. It provides increased port density and total

More information

T Q S Q 1 4 H 9 J 8 2

T Q S Q 1 4 H 9 J 8 2 Specification Quad Small Form-factor Pluggable Optical Transceiver Module 100GBASE-SR4 Ordering Information T Q S Q 1 4 H 9 J 8 2 Model Name Voltage Category Device type Interface Temperature Distance

More information

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium As of June 18 th, 2003 the Gigabit Ethernet Consortium Clause 40 Physical Medium Attachment Conformance Test Suite Version

More information

SFP-10G-SR-Arista-A SFP+, 10GBASE-SR 10G Ethernet Module 850mn, 300m, MMF, LC RoHS6. Approved Optics, Inc.

SFP-10G-SR-Arista-A SFP+, 10GBASE-SR 10G Ethernet Module 850mn, 300m, MMF, LC RoHS6. Approved Optics, Inc. SFP-10G-SR-Arista-A 10Gbase SFP+ Transceiver Features Compliant to SFP+ Electrical MSA SFF-8431 Compliant to SFP+ Mechanical MSA SFF-8432 Multi-rate compliance for Ethernet and Fiber Channel Transmission

More information

Copper and Fiber Optic Cables

Copper and Fiber Optic Cables Copper and Fiber Optic Cables Pietro Nicoletti piero[at]studioreti.it Cables-Engl - 1 P. Nicoletti: see note pag. 2 Copyright note These slides are protected by copyright and international treaties. The

More information

RECOMMENDATION ITU-R BT.1367 *

RECOMMENDATION ITU-R BT.1367 * Rec. ITU-R BT.1367 1 RECOMMENDATION ITU-R BT.1367 * Serial digital fibre transmission system for signals Conforming to Recommendations ITU-R BT.656, ITU-R BT.799 and ITU-R BT.1120 (Question ITU-R 42/6)

More information

XFP 10G MM SR. 10Gbps XFP Optical Transceiver, 300m Reach

XFP 10G MM SR. 10Gbps XFP Optical Transceiver, 300m Reach XFP 10G MM SR 10Gbps XFP Optical Transceiver, 300m Reach Features Supports 9.95Gbps to 10.5Gbps bit rates Maximum link length of 300m (50um,MMF,2000MHz.Km) 850nm VCSEL laser and PIN receiver Low power

More information

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN OVERVIEW Purpose: Examine the common-mode and differential RF ingress levels of 4-pair UTP, F/UTP, and F/FTP cables at an (RJ45) MDI port

More information

Data sheet. E-DAT modul 3 port AP Cat.6A, pure white. Illustrations P/N E EAN Product specification. Page 1/

Data sheet. E-DAT modul 3 port AP Cat.6A, pure white. Illustrations P/N E EAN Product specification. Page 1/ Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification surface-mounted termination unit with E-DAT modul component testing for Cat.6A to ISO/IEC

More information

PRODUCT BRIEF Copper to Fiber Ethernet Media Converter 10/100/1000BASE-T to 1000BASE-SX M38999, 28VDC

PRODUCT BRIEF Copper to Fiber Ethernet Media Converter 10/100/1000BASE-T to 1000BASE-SX M38999, 28VDC 050-103 PRODUCT BRIEF 10/100/1000BASE-T to 1000BASE-SX M38999, 28VDC REV DESCRIPTION DATE APPROVED 2 Preliminary 02/21/2016 MF/MT 3 Add ECCN 05/26/2016 RAS 4 Changed Shock and Vibe Specs, Updated 2D s,

More information

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs 10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs IEEE P802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force 1/15/2019 1 Content EMC Generator Noise Amplitude Coupling-Decoupling-Network

More information

OPENETICS. P/N Gb/sQSFP+SR4Transceiver PRODUCT FEATURES APPLICATIONS STANDARD. Specialist Manufacturer Voice Data Security.

OPENETICS. P/N Gb/sQSFP+SR4Transceiver PRODUCT FEATURES APPLICATIONS STANDARD. Specialist Manufacturer Voice Data Security. P/N 21227. 40Gb/sQSFP+SR4Transceiver PRODUCT FEATURES High Channel Capacity: 40 Gbps per module Up to 11.1Gbps Data rate per channel Maximum link length of 100m links on OM3 multimode fiber Or 150m on

More information

Transmission Media. Two main groups:

Transmission Media. Two main groups: Transmission Media Two main groups: -Wire based media (hardwire, or guided), either : -electric, like twisted pair cable TP, coaxial cable -optic, like fiber optics -Wireless (softwire, or unguided), like

More information

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics Communication accessories Selection guide There are 2 types of Sepam communication accessories: b communication interfaces, which are essential for connecting Sepam to the communication network b converters

More information

HOD /BBA HOD /BBA

HOD /BBA HOD /BBA FEATURES Full duplex over single fiber DC to 60 MHz link bandwidth Link budgets of km [.4 miles] or greater 40 db isolation Low profile ST housing Other options available VCSEL is Class eye safe APPLICATIONS

More information

Kestrel Series DVI Fiber Optic Media Converters, D VDC, Multimode, 850nM, Quadrax

Kestrel Series DVI Fiber Optic Media Converters, D VDC, Multimode, 850nM, Quadrax Kestrel Series DVI Fiber Optic Media Converters, D38999 28VDC, Multimode, 850nM, Quadrax DVI Fiber Transmitters / Receivers FEATURES Optical fi ber link distances up to 500 meters Operating temperature

More information

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8511D3

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8511D3 Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8511D3 PRODUCT FEATURES Hot-pluggable XFP footprint Supports 9.95Gb/s to 10.5Gb/s bit rates Power dissipation

More information

GYM Bilgi Teknolojileri

GYM Bilgi Teknolojileri SFP Transceiver Module GLC SX MM GLC SX MM is 1000Base-SX SFP fiber optic transceiver for multimode fiber and it works at 850nm wavelength, Cisco GLC SX MM SFP is compatible with IEEE 802.3z and could

More information

VCSEL Based 10 Gigabit Serial Solutions

VCSEL Based 10 Gigabit Serial Solutions VCSEL Based 10 Gigabit Serial Solutions 802.3ae Plenary Meeting March 2000 Jack Jewell jljewell@picolight.com 303-530-3189 Introduction Objectives: 1) Assess the PHY links 1, 2, 3 proposed by Vipul Bhatt

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

PROLABS XENPAK-10GB-SR-C

PROLABS XENPAK-10GB-SR-C PROLABS XENPAK-10GB-SR-C 10GBASE-SR XENPAK 850nm Transceiver XENPAK-10GB-SR-C Overview PROLABS s XENPAK-10GB-SR-C 10 GBd XENPAK optical transceivers are designed for Storage, IP network and LAN, it is

More information

Pluggable Transceivers

Pluggable Transceivers DATA SHEET Pluggable Transceivers Industry-Standard Pluggable Transceivers and Direct Attach Cables BENEFITS BUSINESS ALIGNMENT Standards-based technology. Flexible interface options for 100Mbs, 1Gbps,10Gbps,

More information

XFP 10G SR 03km LC Optical Transceiver

XFP 10G SR 03km LC Optical Transceiver Product Specification 1. Features Supports 9.95Gbps to 10.5Gbps bit rates Maximum link length of 300m (50um, MMF, 2000MHz.Km) 850nm VCSEL laser and PIN receiver Low power consumption

More information

ISO/IEC JTC 1/SC 25/WG 3 N 755 Date: Replaces ISO/IEC JTC 1/SC 25/WG 3 N n/a

ISO/IEC JTC 1/SC 25/WG 3 N 755 Date: Replaces ISO/IEC JTC 1/SC 25/WG 3 N n/a ISO/IEC JTC 1/SC 25/WG 3 N 755 Date: 2005-05-18 Replaces ISO/IEC JTC 1/SC 25/WG 3 N n/a ISO/IEC JTC 1/SC 25/WG 3 Customer Premises Cabling Secretariat: Germany (DIN) DOC TYPE: Liaison document TITLE: Letter

More information

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs.

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs. INTRODUCTION Structured Cabling or data cabling (also known Local Area Network or LAN Cabling) is increasing in its deployment for business, commercial and residential use to carry signaling for networks

More information

Data sheet. M12 field plug X-coded, straight. Illustrations P/N MNF881A EAN Product specification. Page 1/

Data sheet. M12 field plug X-coded, straight. Illustrations P/N MNF881A EAN Product specification. Page 1/ Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification M12 Cat.6A X-coded plug based on IEC PAS 61076-2-109 and suitable for field assembly

More information

Multimode fiber media types for 802.3cd

Multimode fiber media types for 802.3cd 1 Multimode fiber media types for 802.3cd P802.3cd, Fort Worth, Texas September 12-16, 2016 Rick Pimpinella Jose Castro Brett Lane Panduit Labs, Panduit Corp. 2 Laser Optimized Multimode Fiber Types Fiber

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60603-7-7 Second edition 2006-06 Connectors for electronic equipment Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with

More information

Physical Test Setup for Impulse Noise Testing

Physical Test Setup for Impulse Noise Testing Physical Test Setup for Impulse Noise Testing Larry Cohen Overview Purpose: Use measurement results for the EM coupling (Campbell) clamp to determine a stable physical test setup for impulse noise testing.

More information

AESA TECHNOLOGY OF LAN CABLE

AESA TECHNOLOGY OF LAN CABLE TECHNOLOGY OF LAN CABLE CONTENT CHAPTER INTRODUCTION CHAPTER LOCAL AREA NETWORK (LAN) CHAPTER STRUCTURED CABLING SYSTEM (SCS) CHAPTER OPTICAL FIBER CABLE CHAPTER STANDARD CHAPTER COPPER LAN CABLE DESIGN

More information

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation) ACR (Attenuation to Crosstalk Ratio) The distance between the wanted signal and the interfering signal (ACR) is an important factor for the transmission quality. To ensure a faultless transmission, the

More information

Suggested Statement/Substantiation for The PoE Task Group PIs

Suggested Statement/Substantiation for The PoE Task Group PIs All Text was agreed without objection by polling on the 6/2/17 call, blue text may be used in PI s but probably not if a single PI is filed. Yellow highlighted names (only shown on 840.160 PI) are individuals

More information

Arista Networks QSFP-100G-SR4-AR. Part Number: QSFP-100G-SR4-AR QSFP-100G-SR4-AR OVERVIEW PRODUCT FEATURES APPLICATIONS.

Arista Networks QSFP-100G-SR4-AR. Part Number: QSFP-100G-SR4-AR QSFP-100G-SR4-AR OVERVIEW PRODUCT FEATURES APPLICATIONS. Part Number: QSFP-100G-SR4-AR QSFP-100G-SR4-AR OVERVIEW Th QSFP-100G-SR4-AR is a parallel 100 Gbps Quad Small Form-factor Pluggable (QSFP28) optical module. It provides increased port density and total

More information

10GBASE-S Technical Feasibility RECAP

10GBASE-S Technical Feasibility RECAP 10GBASE-S Technical Feasibility RECAP Picolight Cielo Stratos Lightwave Corning CDT-Optical Lucent IBM IEEE P802.3ae Austin, TX November 2001 Plenary meeting 1 10GBASE-S Feasibility supporters Bob Grow,

More information

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

10GBASE-T. Channel Model Proposal

10GBASE-T. Channel Model Proposal Channel Model Proposal March 2004 Orlando, FLA 0 Overview Purpose of presentation: Get agreement on a baseline channel models that will be used for evaluating PHY proposals Channel models must be acceptable

More information

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General Install & Go SMARTen (Cat.6A) STP Trunk General Cat 8 Filler Cat.6A U/FTP Horizontal cables (x6) Fan-Out Cables Cat.6A STP Keystones TRUNK CABLE SECTION VIEW Trunk Isometric Front View RiT s Copper Install

More information

GLC-SX-MMD-SO SFP, 1G, 550m, Multi Mode, 850nm, with DOM

GLC-SX-MMD-SO SFP, 1G, 550m, Multi Mode, 850nm, with DOM General Description The 1G SFP optical transceivers are designed for Storage, IP network and LAN. It is a fully integrated 1 Gbps optical transceiver module. This module is designed for multimode fiber

More information

Fiber Optic Principles. Oct-09 1

Fiber Optic Principles. Oct-09 1 Fiber Optic Principles Oct-09 1 Fiber Optic Basics Optical fiber Active components Attenuation Power budget Bandwidth Oct-09 2 Reference www.flukenetworks.com/fiber Handbook Fiber Optic Technologies (Vivec

More information

Investigations of the thermal impact of remote powering over generic cabling

Investigations of the thermal impact of remote powering over generic cabling Investigations of the thermal impact of remote powering over generic cabling Presented by Alan Flatman, LAN Technologies Prepared by Mike Gilmore, e-ready Building Limited, UK Arne Keller, Commscope, Sweden

More information

Ethernet & High Speed Networks. Quadrax Contact up to Cat6 MIL-DTL-38999/ARINC 600/EN2997/EN3646

Ethernet & High Speed Networks. Quadrax Contact up to Cat6 MIL-DTL-38999/ARINC 600/EN2997/EN3646 Ethernet & High Speed Networks Quadrax Contact up to Cat6 MIL-DTL-38999/ARINC 600/EN2997/EN3646 Quadrax Contact Presentation Today s technology for Aeronautic and Military equipment is more and more complex,

More information

Product Bulletin. Belden DataTwist 4800 Cables

Product Bulletin. Belden DataTwist 4800 Cables Product Bulletin PB 296 Belden DataTwist 4800 Cables DataTwist 4800 UTP Cables provide significant headroom and robust data transmission performance for today s most demanding applications. The cables

More information