RFI & EMI Components and Subsystems

Size: px
Start display at page:

Download "RFI & EMI Components and Subsystems"

Transcription

1 RFI & EMI Components and Subsystems

2 In 1979 Filter Networks began manufacturing RFI and EMI components. Filter Networks was acquired in 1997 by EMI Technologies. Our mission then, as now, was simple: to design and manufacture custom products, deliver on time and within specification, all at a reasonable price. By maintaining diverse engineering and manufacturing talents, Filter Networks has been able to respond to the unique requests of our customers over a broad range of RFI and EMI components. Today, Filter Networks is in a 0,000 square foot facility located in Salisbury, MD. We continue to be a world leading manufacturer of quality RFI and EMI components and subsystems used for military, industrial, and commercial applications. With over years of design and manufacturing experience, Filter Networks is committed to providing our customers with technically advanced, high quality products, at competitive prices. Our vast experience allows us to tailor standard off-the-shelf products to meet the most demanding requirements, without the need for costly development efforts. All products offered by Filter Networks are subject to the same rigorous design, manufacturing and inspection criteria. Our manufacturing, testing, and inspections conform to the requirements of MIL-I-48A and the principles set forth in ISO Your benefit from this effort is the assurance that Filter Networks products will work correctly right out of the box. The products described in this catalog have resulted from over years of design experience with the utilization of the latest computer aided technology. In addition, all products have been analyzed by our own propriety software programs that review electrical as well as physical parameters such as realizable Q plating techniques, and environmental considerations. Filter Networks designs are developed for ease of manufacturing and flexibility as a prime criteria. This coupled with adequate inventories of raw materials and in-house control of all critical process from design through manufacturing and testing, yields deliveries that are generally quoted in days, not weeks or months. At Filter Networks, we believe that putting our trademark on the product is a commitment to you of quality, service and satisfaction. This trademark is our signature and it represents a continued tradition of unparalleled service to the RFI and EMI industry.

3 Contents Introduction Ordering and General Information 4 In-House Testing and Environmental Capabilities Filter Technical Information 6-9 Power Line, Power Entry Filters Tempest Line Filters 11 Cylindrical/Ceramic Filters 1 Power Entry Filters for Traffic Control 1 Surge Protectors, Lowpass, Highpass 14 and Bandpass Filters Data Line, Control Line Filters 1 RFI Filters for Fiber Optic Couplers 16 Inductors, Transformers and Chokes 17 Standard Stock Items Copyright Filter Networks 1998

4 Ordering and General Information How to Order Part numbers are assigned at time of order. If you have generated a part number, give the name of the component and the frequency range as stated in the catalog. If special options or non-standard features are desired, they should be fully described and a unique part number will be assigned. Special modifications for unusual applications, custom components and adaptation of existing parts can be designed and developed by our engineering department. A qualified staff of experienced sales and design engineers is available to assist you in specifying components for your special requirements. Ordering address: Filter Networks 8 Coles Circle, Suite C Salisbury, MD 14 Phone: Fax: sales@filternetworks.com Web: Our CAGE code is 8Y4 Orders may also be placed with our sales representative in your area. Determination of price, terms and conditions of sales and final acceptance of orders may only be by our staff in Salisbury, Maryland. Payment Options Filter Networks offers many convenient payment methods, including: Open Account (subject to credit approval), Mastercard/Visa, and Letters of Credit. Please specify payment method at time of order. Product Specification Published specifications are subject to change by the factory at any time. We reserve the right to discontinue items without prior notice. Delivery If a carrier is not specified at the time of order, shipment will be made by the most economical method. For rush service, we will ship by air freight, air express, air parcel post or others, as requested. Firm delivery dates are given at time of quotation. Filter Networks maintains complete inventory so that many items may be delivered within 4 hours when quoted by the factory. Packing and Packaging Packing and Packaging is normally supplied to Best Commercial standards. Packaging to military requirements, including Bar Coding is available on request. Warranty Products manufactured by Filter Networks are warrantied against defective materials and workmanship for a period of one year from the date of shipment. Filter Networks obligation for any defect shall be limited to the repair of the defective part. Filter Networks assumes no liability if defects result from improper use, operation above rated capacities, repairs not made by us, or misapplication of equipment. No other warranty is expressed or implied. Filter Networks neither makes nor authorizes any other person to make any other warranty concerning its products. Filter Networks is not liable for consequential damages. Warranty returns must first be authorized by our sales office and must be returned prepaid. 4

5 In-House Testing and Environmental Capabilities Test Function Immersion Seal Resistance to Solvents Solderability Resistance to Soldering Heat Terminal Strength Dielectric Withstanding Voltage Insulation Resistance DC Resistance Capacitance Inductance Quality Factor (Q) High Temperature Life Test Low Temperature Cycling Thermal Shock Multi-Component Burn-In Current Measurement Radiographic Inspection Capabilities -00 VAC 1 to 0 VDC 1 8 M Ohms 0 to 000 M Ohms 0 to 99 mf 0 to 9900 H -6 C to + C -6 C to + C DC up to Amp, VAC 0 Hz Phase 1 kw max VAC Hz Phase kw up to A rms Multiple Part -Ray Reference MIL-STD-0, 8 MIL-STD-, 88 MIL-STD-0 MIL-STD-0 MIL-STD-0 MIL-STD-0 MIL-STD-0 MIL-STD-0, 88 MIL-STD-0 MIL-STD-0 MIL-STD-0 Quality Factor (Q) MIL-STD-0, 81 MIL-STD-0, 8 MIL-STD-0 MIL-STD-0 MIL-STD-0

6 Filter Technical Information Cylindrical CYLINDRICAL FILTERS FOR POWER LINE APPLICATIONS MILITARY GRADE CYLINDRICAL FILTERS Filter Networks Cylindrical Filters offer superior interference suppression for AC or DC power lines. Filter Networks Cylindrical Filter designs are manufactured, inspected, and tested to meet the requirements of the military specifications MIL-F-8861 and MIL-F-17. Compact plated brass tube housings and hermetic terminal seals enable reliable operation in hostile moisture and shock/vibration environments. The use of dependable cylindrical dielectric feed through capacitors ensures dramatic broadband (0 KHz to 1 GHz) interference suppression (up to db) while withstanding line voltages as severe as 0 VAC 0 Hz at temperature extremes from - C to +1 C. By selecting from a wide range of standard capacitor values and custom wound inductors, Filter Networks can design a cylindrical filter to meet specific voltage, current, performance and environmental requirements. Standard designs are available for many existing MIL-F-17 and MIL-F-8861 slash sheet designs. Filter Networks responds to your interference requirements with state-of-the-art technology and old fashioned personal customer service. Filter Networks offers a variety of quality assurance plans for its Cylindrical Filter product line including combinations of thermal shock, burn-in, and full military Gp A, B, C testing in accordance with either MIL-F-17 or MIL-F-8861 (Class B) requirements. Filter Networks responds to your interference requirements with state-of-the-art technology and old fashioned personal customer service. Let Filter Networks application engineers discuss your needs. You ll be pleased to find The Difference is Response! 6

7 7

8 Part Number Current Rating Line-to-Line Operating Voltage ( Hz) Temperature Range Mating Connector Minimum Insertion Loss (db) Per MIL-STD-0 KHz 1 KHz 00 KHz 1 MHz MHz MHz 1 GHz NF-46 Amps VAC - to 8 C MS-6-14S-7S NF-47 Amps VAC - to 8 C MS-6-14S-7S 4 64 NF-48 Amps VAC - to 8 C MS-8-SL-S 4 NF-49 Amps VAC - to 8 C MS-6-14S-7S 4 NF-419 Amps VAC - to 8 C MS-8-SL-S 8

9 POWER LINE, POWER ENTRY FILTERS FOR TEMPEST APPLICATIONS Offering high-power performance in a space efficient, low cost, standard package, Filter Networks NF-46, NF-47 and NF-48 Power Line Filters are designed to meet demanding Tempest requirements for radio frequency interference suppression. These state-of-the-art Tempest filters feature a choice of connectors, lead arrangements and single/dual circuits for AC and DC applications. These Power Line Filters feature hermetically sealed MS connectors and glass sealed terminals. Each filter is required to pass MIL-STD-0 and 88 seal tests to ensure reliable performance under severe environmental conditions. Designed to operate between - C and +8 C at VAC Hz line-to-line voltages, this series of filters is available up to 0 amps current ratings. Careful consideration has been given to internal construction to ensure excellent I/O Tempest isolation and provide superior RF attenuation from 0 KHz to 1 GHz (and beyond!). One of two standard configurations may be selected to match filter-to-circuit impedance. Rugged tin-plated steel enclosures are constructed for convenient bulkhead mounting with two machine screws. These filters have been Tempest tested and approved as a RFI Power Supply-Isolator Filter for transmitter and receiver, fiber optic communication links. The engineering staff of Filter Networks have decades of experience in the filter and noise suppression field and have been producing environmental and safety products since They are pleased to present a new and high performance line of radio frequency interface filters for the Tempest Power Line requirements. Filter Networks engineering staff will be pleased to discuss your filter needs! 9

10 Power Line, Power Entry Filters for Tempest Applications High-power performance in a compact package Designed to meet demanding Tempest requirements for RFI suppression 0 KHz to 1 GHz (and beyond!) Part Number NF-41 NF-41 Current Rating 1 Amp Amps Operating Voltage ( Hz) /, Hz /, Hz Mating Connector MS 6-SL-S MS 6-SL-S Operating Temperatures - C to +8 C NF-49 Amps /, Hz 0 Custom steel enclosures with bulkhead mounting to suit your needs NF-1 NF-49 Amps Amps /, Hz /, Hz 0 MS 6-SL-S Available up to 0 AMPs NF-89 Amps /, Hz TEC 0 Current ratings for VAC ( Hz) line-to-line voltages New Low Leakage Higher line-to-line voltage available upon request

11 Tempest Line Filters Light Part Number Current Rating Operating Voltage ( Hz) Mating Connector Same form, fit and function as the standard Tempest Filter Line without the large line to ground capacitance NF-6 NF-7 NF-8 Amps Amps Amps VAC VAC VAC MS 6-14S-7S MS 6-14S-7S MS 6--SL-S Lower than. ma of AC leakage current as required by UL 18 for filters used in class 1 grounded VAC Lower resistance for reduction of equipment (internal heating) Operating Temperatures - C to +8 C 11

12 Cylindrical/Ceramic Filters Dependable ceramic dielectric feed thru capacitors Outstanding interference suppression with several cut-off frequencies Cylindrical Filters for Signal Line, Power Line, EMI, RFI Filtering Compact & durable package Available with a variety of I/O Terminals & Connectors Cylindricals are available in a variety of AC/DC voltages Operating Temperatures - C to +1 C Mechanical Information.01.8 L.188 MA Diagram A THD END Diagram B.0 Internal Tooth Lockwasher Hex Nut 1/4 x 8UNF-A THD THD END Diagram C Diagram D.0 Dia Hole ( Places) Part Number Voltage 1 C Pass Band Minimum Insertion Loss (db) Per Standard MIL-STD-0 0 MHz MHz MHz 1 GHz CA-496 VDC DC-1 MHz < db CA-497 VDC DC- MHz < db CA-498 VDC DC-0 MHz < db 0 1

13 Power Entry Filters for Traffic Control Designed for RF protection of electrical traffic signal controllers. NF-6 has been tested and certified as an approved component for protection of traffic light control systems, in major metropolitan areas. Environmentally protected custom steel enclosures. Available w/optional surge protection. NF-6 Operating Temperatures - C to +8 C 1 Volts, Hz A.C., AMP steady state Insertion Loss Measured per MIL-STD-0 in Ohm System db K 00K 1M 0M M M M M Frequency (HZ.) Typical Measurements 1

14 Surge Protectors High end lightning strike surge protector VDC Custom designs to suit your surge needs SA-871 Lowpass, Highpass and Bandpass Filters In surface mount configuration Audio, communication and telemetry applications Cut-off frequencies up to 1 GHz 14

15 Data Line, Control Line Filters Available in a variety of line-to-line & line-to-ground Impedances (i.e. ohms) Approved for secure filter applications Hermetically sealed, custom steel housing and glass-metal compression terminals Operating Temperatures - C to +8 C Dual style DC circuits from DC to 1 GHz (and beyond) NF-619 Standard and custom designs available Impedance Insertion Loss Filter Applications Part Number Rating Line to Line Line to Ground Measured per MIL-STD-0 Ohm/ Ohm.14 MHz. MHz.7 MHz 1MHz to 1GHz Control Line Filters NF 619 NF 60 x 1A, VDC x 1A, VDC, Hz Ohm Ohm db db db db Ohm Ohm db db db db 1

16 RFI Filters for Fiber Optic Couplers Available in single and dual circuit configurations Low profile packaging with connectors Standard and custom designs available Mechanical Information NF-179 NF-9 NF NF-4A CONN OUT CONN OUTPUT 1.0 Part Number Operating Voltage Current Rating Circuit Configuration Connector Type KHz Typical Insertion Loss (db) Per MIL-STD-0 KHz KHz 1 MHz MHz MHz 1 GHz NF-179 VDC 0 ma Single 74-9 Jack/Leads > > > > NF-9 VDC 0 ma Single 71A Jack/Leads > > > > NF-87 VDC 0 ma Single 71H Jack/ 71A Jack > > > > NF-4A 0 VAC 0 ma Dual 74-49A Jack/Leads > > > > 16

17 Inductors, Transformers & Chokes Applications for these products range from simple chokes, inductors and transformers used in telephone equipment to sophisticated devices for commercial and military electronics Custom designed for your application needs Wide range of customized surface mount configurations (to include): EE, EP, EFD, EI, RM, pot core and toriod Constructed of ferrites, laminations, Mpp, high flux and cut cores 17

18 18 NF-18 NF-17 Part Number NF- NF-4 NF-0 NF-49 NF- NF-94 NF-419 NF-41 NF-44 NF-446 NF-41 NF-4 NF-4 NF-48 NF-49 NF-46 NF-471 NF-48 NF-490 NF-491 NF-494 NF-1 NF- NF-1 NF- NF- NF-6 NF-7 NF-8 NF-9 NF- NF-1 NF-4 NF-6 NF-7 NF-8 NF- NF-48 NF-46 NF-47 Voltage Frequency Hz Amps Circuits Insertion Loss (CM/DM) 1 MHz / / / / / / / / / / / / / 0 DC DC PH PH PH 1 Input Type MS6-14 MS6-14 MS6- MS6-14 MS6-14 MS6- MS6- MS6-16 MS6- MS6-14 MS6- MS6-14 MS6- MS6- PWR CORD MS-16 MS11-1 MS0-16 MS0-0 MS6-14 MS6-14 MS6- Term Block / / / / / / / / / / / / / / / / / / / / / / / / / 4 KHz / / /16 /16 /16 8/8 8 17/ Output Type Term Block AC Leakage 1 ua ma ma ma 1 ma ma.6 ma ma ma. ma.0 ma 0 ma 0 ma. ma. ma. ma.6 ma 4 ma Fuse Switch 1 KHz 1/0 64 1/7 64 / /48 68/48 /48 61/6 9/ KHz 46/44 / / / / 79/77 9 7/ 1 9/61 / / / / / / / MHz 0/64 / / / / / / / 1 GHz / / / / / MHz / / / / / /18 Standard Stock Items

19 19 NF-47 NF-7 Part Number NF-8 NF-67 NF-7 NF-9 NF-94 NF-99 NF-616 NF-619 NF-60 NF-68 NF-69 NF-6 NF-671 NF-67 NF-676 NF-687 NF-71 NF-77 NF-7 NF-74 NF-7 NF-76 NF-741 NF-74 NF-747 NF-748 NF-7 NF-761 NF-76 NF-76 NF-766 NF-77 NF-776 NF-7 NF-79 NF- NF-4 NF-49 NF- Voltage Frequency Hz Amps Insertion Loss (CM/DM) / / 00 / / / / 08 / DC 0 DC DC DC Circuits PHD 1 1 PHD PHD PHD PHD Input Type MS6- MS-14 PWR CORD MS6-14 MS6-14 PWR CORD PWR CORD PWR CORD PWR CORD PWR CORD MS6- PWR CORD MS-0 MS6-14 MS QUICK MS6-14 QUICK MS474-1 MS- MS6-8 / / / / /4 /4 / / / / / / / 08 / / / / / 8 / / KHz /1 /16 /16 64/47 0/0 /0 0/4 7/8 /0 0/18 /4 7/ / /4 Output Type MS-14S CASE QUICK QUICK QUICK QUICK MS-S AC Leakage. ma ma. ma 1.0 ma 0 ua.0 ma.0 ma 0 ma.0 ma 1. ma. ma. ma. ma. ma.0 ma. ma. ma. ma. ma ua. ma.0 ma. ma ma. ma 00 ma. ma. ma. ma 00 ma ua. ma 1.6 A Fuse Switch 1 KHz 68/ /6 64 /17 0 /48 /48 4 / /4 / /8 / / /67 / 0/8 / / / 7/4 00 KHz / /18 47/0 / / 9 / 48/ / 48/ / / / / 1./41 / / 90/90 /6 /0 / / 1 MHz / 0 /4 / / / / 6/ / 6/ / / / / 6/4 / / 90/90 / / MHz / / / / / / / / 90/ / / / / / / / 90/90 / / 1 GHz / / / / / / / / / / / / / / / 90/ / / MHz / 7 / / / / / / / / / 0/ / / / / / 90/ / / /16

20 8 Coles Circle, Suite C Salisbury, Maryland fax sales@filternetworks.com

Table of Contents. Facility EMI Filter Products

Table of Contents. Facility EMI Filter Products Table of Contents Filter Selection Guide Facility EMI Filters...............................................4, 5 Signal/Data/Control Filters........................................6, 7 Technical Notes................................................8,

More information

Electromagnetic Integrated Solutions

Electromagnetic Integrated Solutions Complete line of coaxial EMI electromagnetic spectrum management solutions, from components to complex assemblies. Electromagnetic Integrated Solutions Capabilities & Certifications API Technologies has

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) About JFW Industries, Inc. Founded in 1979 in Beech Grove, Indiana, JFW Industries Inc. is a world leader in designing

More information

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer 110 Toledo Street Farmingdale, NY 11735 USA http://www.netech.org 510-USER-Manual Rev3 10/29/2007 Dear User, We appreciate your purchase of the LKG

More information

About JFW Industries, Inc.

About JFW Industries, Inc. About JFW Industries, Inc. Founded in 1979 in Beech Grove, Indiana, JFW Industries Inc. is a world leader in designing and manufacturing of passive RF components and application specific test systems.

More information

Installation Filters. High Performance. Installation Filters. Product Range. Contact T: +44 (0) F: +44 (0) E:

Installation Filters. High Performance. Installation Filters. Product Range. Contact T: +44 (0) F: +44 (0) E: Installation Filters /12 Installation Filters High Performance Installation Filters This information is for guidance only. 212 MPE Limited Introduction MPE Limited is a world leading manufacturer of high

More information

OUR MISSION: TO PROVIDE HIGH QUALITY PRODUCTS, TECHNICAL EXCELLENCE & PRACTICAL ENGINEERING AT AN ECONOMICAL PRICE

OUR MISSION: TO PROVIDE HIGH QUALITY PRODUCTS, TECHNICAL EXCELLENCE & PRACTICAL ENGINEERING AT AN ECONOMICAL PRICE Practical & Compact EMR Corp. Systems Solutions for all LMR & PMR applications offering the most practical approach to full duplex combining in mobile and base station applications. These are single antenna

More information

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE LNFR-100E OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com

More information

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz Page 1 of 10 INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK Model LI-4100 10 khz to 10 MHz Page 2 of 10 Table of Contents 1.0 Introduction... 3 2.0 Product Description... 4 3.0 Product Specifications...

More information

EMR CORPORATION N. 25th Avenue Phoenix, Arizona Toll Free: Tel: (623) Fax: (623)

EMR CORPORATION N. 25th Avenue Phoenix, Arizona Toll Free: Tel: (623) Fax: (623) Practical & Compact EMR Corp. Systems Solutions for all LMR & PMR applications offering the most practical approach to full duplex combining in mobile and base station applications. These are single antenna

More information

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz). 121 Series Coaxial Snap On & Screw On Types / 50 Ohm & 75 Ohm These 50 and 75 Ohm coaxial connectors are easily inserted into your printed circuit board using an insertion tool. Solder is eliminated and

More information

K&L s 170,000 square foot facility vertically integrates design, manufacturing, and test centers. Capabilities and certifications are as follows:

K&L s 170,000 square foot facility vertically integrates design, manufacturing, and test centers. Capabilities and certifications are as follows: K&L Microwave (MPG Salisbury) has been a key supplier to space programs since the Apollo 17 lunar sounder experiment in 1972. Across the decades, K&L has supported customers with high reliability filter

More information

ARF461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY PD-94588C. Description ARF

ARF461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY PD-94588C. Description ARF PD-94588C ARF461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY Description The ARF Series EMI filter has been designed to provide full compliance with the input line reflected ripple current requirement specified

More information

RFX. Type N RG58, 141, 142 Straight Plug Type N Connectors» Cable Straight. Jack 50 Ohm Yes

RFX. Type N RG58, 141, 142 Straight Plug Type N Connectors» Cable Straight. Jack 50 Ohm Yes Please note: Images are for reference only Amphenol Part Number: Description: Product Series: Product Type: Connector Body Style: Gender: Impedance: RoHS Compliant: 082-5376-RFX RG58, 141, 142 Straight

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL Copyright 2015, ATI Audio Inc. DESCRIPTION Your ADA416-XLR provides four independent one-in by four-out circuit groups. A four-output

More information

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC PD5-RM-B PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 www.spectradynamics.com

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 1000 Vdc 4 Fully Programable Outputs 4 Single and Dual Outputs 4 Wide Input Ranges (10-20Vdc, 18-36Vdc) 4 1000 Vdc Output Isolation 4 Continuous

More information

Opus 21 s80 Integrated Amplifier Owner's Manual

Opus 21 s80 Integrated Amplifier Owner's Manual Opus 21 s80 Integrated Amplifier Owner's Manual r e s o l u t i o n From all of us at Resolution Audio, thank you for choosing the Opus 21 s80 amplifier. We went to great lengths to design and produce

More information

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL Copyright 2011, ATI Audio Inc. DESCRIPTION Your DA208 or DA416 provides two (DA208) or four (DA416) independent one-in by four-out

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 1000 Vdc 4 Low Profile 4 Single and Dual Outputs 4 Ultra Wide Input Ranges (9-36Vdc, 20-60Vdc, 36-72Vdc) 4 1000 Vdc Output Isolation 4 Continuous

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment 1995 Metric CSJ 3483-01-010 SPECIAL SPECIFICATION ITEM 6329 Multimode Video Fiber Optic Transmission Equipment 1.0 Description. This Item shall govern for the furnishing and installation of Video Fiber

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. FEATURES AND SPECIFICATIONS Features and enefits Exceeds Category 5 performance

More information

Multi-Couplers And Distribution Amplifiers 0.5 MHz to 18 GHz

Multi-Couplers And Distribution Amplifiers 0.5 MHz to 18 GHz Multi-Couplers And Distribution Amplifiers 0.5 MHz to 18 GHz YOUR CHALLENGE IS OUR PROGRESS 3 Foshay Road, Dudley, MA 01571 Tel. 860.935.0280 Fax 508.943.0400 www.ifengineering.com About our Company I.F.

More information

Kete Microwave Electronics Co., Ltd.

Kete Microwave Electronics Co., Ltd. HOW TO ORDER: KTFC - X XX X - XX XX - XXX XX - XXXX - XXXX Large Dia. Body Width Rated Voltage Kete Small Dia Lead Dia. VDC/VAC Feedthru Capacitors Dielectric X=X7R, S=SL, N=NPO (-55 ~+125 ) Y=Y5U, Y5V

More information

PMT/UMT(275) Power Gap Description and Use Application Note

PMT/UMT(275) Power Gap Description and Use Application Note Application Note Introduction The PMT(275)/UMT(275) Series has been designed for use in applications where a rugged miniature sized surge arrester is needed capable of high speed of response. This Power

More information

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem 1993 Specifications CSJ 2266-02-095 SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic RS- 232 Data Modem

More information

200Amp AC Clamp Meter + NCV Model MA250

200Amp AC Clamp Meter + NCV Model MA250 User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,

More information

Model 1791 VHF Radio User's Manual

Model 1791 VHF Radio User's Manual Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power

More information

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra Performance Series 360w RMS 4-Channel Amplifier Kit For 2016-2018 Harley RoadGlide Ultra # JMAA-3600HR16-UL 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions Product

More information

CPC1976Y. AC Power Switch INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information. Applications.

CPC1976Y. AC Power Switch INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information. Applications. AC Power Switch Parameter Rating Units AC Operating Voltage 2-24 V rms Load Current 2 A rms On-State Voltage Drop. V rms (at I L = 2A rms ) Blocking Voltage 6 V P Features Load Current up to 2A rms 6V

More information

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1995 Metric CSJ's 1047-03-056 & 0008-08-066 SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation

More information

SERIESN50, COAXIAL CONNECTORS

SERIESN50, COAXIAL CONNECTORS SERIESN50, COAXIAL CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER N connectors are available with 50 and 75 impedance. The frequency range extends to 18 GHz, depending on the connector and cable type.

More information

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra 180w Performance Series Amplifier Kit For 2015-2018 Harley RoadGlide/ Ultra # JMAA-1800HR15 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions Product Description This

More information

HECR SERIES Avionicap

HECR SERIES Avionicap HECR SERIES Avionicap Avionicap Series Minature Metallized Polycarbonate - Hermetically Sealed The Avionicap HECR type capacitor is a hermetically sealed version of our Avionicap ECR type series, which

More information

INSTRUCTION MANUAL LKG

INSTRUCTION MANUAL LKG INSTRUCTION MANUAL LKG 610 Electrical Safety Analyzer With 10 ECG Connectors 110 Toledo Street Farmingdale, NY 11735 USA Homepage: www.netech.org Dear User, We appreciate your purchase of the LKG 610 Electrical

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS IM-360 Model 4238 GaAs Switched Programmable Attenuators This documentation may not be reproduced in any form, for any purpose unless authorized in writing by API

More information

Kotron Model 82 CE RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art

More information

CPC1966YX6 Rapid Turn-On AC Power Switch

CPC1966YX6 Rapid Turn-On AC Power Switch Rapid Turn-On AC Power Switch Parameter Rating Units AC Operating Voltage - 24 V rms Load Current 3 A rms On-State Voltage Drop 1.1 V P (at = 2A P Blocking Voltage 6 V P Features Load Current up to 3A

More information

SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data

SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data 2004 Specifications CSJ 0617-01-169 SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data 1. Description. This Item shall govern for the furnishing and installation of Video optical transceiver

More information

Kete Microwave Electronics Co., Ltd.

Kete Microwave Electronics Co., Ltd. HOW TO ORDER: KTFC - X XX X - XX XX - XXX XX - XXXX - XXXX Large Dia. Body Width Rated Voltage Kete Small Dia Lead Dia. VDC/VAC Feedthru Capacitors Dielectric X=X7R, S=SL, N=NPO (-55 ~+125 ) Y=Y5U, Y5V

More information

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER HPDA15RMC OPERATING MANUAL SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2. Louisville, CO 80027 Phone: (303) 6651852 Fax: (303) 6046088 www.spectradynamics.com

More information

Instruction Manual Model M Switch, DPDT, Manual Select

Instruction Manual Model M Switch, DPDT, Manual Select Instruction Manual Model 1582-70M Switch, DPDT, Manual Select November 2018 Rev 0 STATUS MODEL 1582 CROSS TECHNOLOGIES INC. MANUAL SELECT POWER Data, drawings, and other material contained herein are proprietary

More information

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA MLA10641 High Performance Microstepping Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 1.0 SCOPE This Product Specification covers the 1.27 mm (.050 inch) centerline (pitch) printed circuit board (PCB) modular jack connector series with selective gold and tin plating. 2.0 PRODUCT DESCRIPTION

More information

Model 9305 Fast Preamplifier Operating and Service Manual

Model 9305 Fast Preamplifier Operating and Service Manual Model 9305 Fast Preamplifier Operating and Service Manual This manual applies to instruments marked Rev 03" on rear panel. Printed in U.S.A. ORTEC Part No.605540 1202 Manual Revision B Advanced Measurement

More information

AF28461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY PD Description

AF28461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY PD Description PD-97851 AF28461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY Description The AF28461 Series EMI filter is designed to provide full compliance with the input line reflected ripple current requirement specified

More information

JAMP-630HC14-ULP. Installation and Operation Instructions. ROKKER XXRP 630w Amplifier Kit For Harley Ultra/Ultra Ltd.

JAMP-630HC14-ULP. Installation and Operation Instructions. ROKKER XXRP 630w Amplifier Kit For Harley Ultra/Ultra Ltd. ROKKER XXRP 630w Amplifier Kit For 2014-2018 Harley Ultra/Ultra Ltd. Fairing # JAMP-630HC14-ULP 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions Product Description

More information

+Vin. Input Return. +Vin. Input Return

+Vin. Input Return. +Vin. Input Return PD-97874A SF461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY Description SF461 Series is part of the International Rectifier HiRel family of products. The SF461 Series EMI filter is designed to provide full

More information

CPC1966 AC Power Switch

CPC1966 AC Power Switch AC Power Switch Parameter Rating Units AC Operating Voltage - 24 V rms Load Current 3 A rms On-State Voltage Drop.8 V rms (at = 3A rms Blocking Voltage 6 V P Features Load Current up to 3A rms 6V P Blocking

More information

50 Ohm Components Brochure

50 Ohm Components Brochure 50 Ohm Components Brochure Available now to download from our website, this brochure covers JFW's standard 50 Ohm components, which includes: Programmable Attenuators Manually Variable Attenuators Fixed

More information

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year

More information

New hermetically sealed panel mount filters

New hermetically sealed panel mount filters New hermetically sealed panel mount filters Introduction Syfer Technology Ltd manufactures quality multilayer ceramic components supplied to a worldwide customer base. Customers utilise Syfer s components

More information

MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER

MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER MIRAGE BD-38-G Dual Band Amplifier INTRODUCTION: The Mirage BD-38-G is a 80/60 watt dual band power amplifier for use with today's dual band handie talkies operating

More information

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG Performance Series 360w 4-CH Amplifier Kit For 2014-2018 Harley Street Glide with Lower/Rear s # JMAA-3600HC14-SG 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions

More information

CPC1972 AC Power Switch

CPC1972 AC Power Switch AC Power Switch Parameter Ratings Units Blocking Voltage 8 V P Load Current 2 ma rms On State Voltage Drop 3 V rms (at I L = 2 ma rms Operating Voltage V rms Features Load Current up to 2mA rms 8V P Blocking

More information

JAMP-700HR15-RCP. Installation and Operation Instructions. ROKKER XXRP 700w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers

JAMP-700HR15-RCP. Installation and Operation Instructions. ROKKER XXRP 700w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers ROKKER XXRP 700w Amplifier Kit For 2015-2018 Harley RoadGlide with Lower/Rear s # JAMP-700HR15-RCP 2018 J&M Corporation. All rights reserved. 4/18 Installation and Operation Instructions Product Overview

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC Performance Series 360w Amplifier Kit For 2015-2018 Harley RoadGlide with Lower/Rear s # JMAA-3600HR15-RC 2017 J&M Corporation. All rights reserved. 9/17 Installation and Operation Instructions Product

More information

DL102 Counter Loop Amplifier

DL102 Counter Loop Amplifier DL102 Counter Loop Amplifier USER MANUAL MAN 234A Contents Overview...3 System Includes...3 Maintenance and Recycling Instructions...3 Safety Information...4 Quick Setup...5 Setup...6 Loop Amplifier...6

More information

SMB Connectors. RF Coax Connectors. Product Facts

SMB Connectors. RF Coax Connectors. Product Facts SMB Connectors Product Facts SMB offers snap-fit coupling for quick connect/disconnect Choice of Commercial or High Rel Connectors 50 and 75 Ω MIL-Type connectors available Straight plugs and jacks are

More information

CPC1964B AC Power Switch

CPC1964B AC Power Switch AC Power Switch Parameter Rating Units AC Operating Voltage - 28 V rms Load Current 1. A rms On-State Voltage Drop 1.4 V P (at = 1.A P Blocking Voltage 8 V P Features Load Current up to 1.A rms 8V P Blocking

More information

PRODUCT SPECIFICATION. This specification defines the detailed requirements for the Minitek Pwr3.0 wire to wire and wire to board connectors.

PRODUCT SPECIFICATION. This specification defines the detailed requirements for the Minitek Pwr3.0 wire to wire and wire to board connectors. 1.0 SCOPE 1 of 8 E This specification defines the detailed requirements for the Minitek Pwr3.0 wire to wire and wire to board connectors. 2.0 APPLICABLE DOCUMENTS The following documents, of the latest

More information

Master Reference Unit

Master Reference Unit Master Reference Unit Instruction Manual Model D10096-000 Driven by Excellence D.C. DRIVES, A.C. INVERTERS, SOLID STATE STARTERS, SYSTEM INTERFACE CIRCUITS AND ENGINEERED SYSTEMS Driven by Excellence D.C.

More information

PARALLEL ELEMENT ANTENNA MODEL PEA-30

PARALLEL ELEMENT ANTENNA MODEL PEA-30 INSTRUCTION MANUAL PARALLEL ELEMENT ANTENNA MODEL PEA-30 10 khz 30 MHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PROPRIETARY. UNAUTHORIZED REPRODUCTION IS FORBIDDEN.

More information

Installation Instructions

Installation Instructions J&M STAGE-5 ROKKER XXR Custom 700w Amplifier Installation Kit for 2015-19 Harley Roadglide CVO Ultra # JAMP-700HR15-ULP-CVO 2019 J&M Corporation. All rights reserved. 4/19 Installation Instructions Product

More information

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE Linear Tube Audio Takoma Park, MD, USA WARNING: For safety, the cover of this amplifier should be secured at all times. DC voltages as high

More information

QUALIFICATION TEST SUMMARY REPORT ESR-9414 Qualification Type Testing of Amphenol Corporation s 2M805 Series Connector

QUALIFICATION TEST SUMMARY REPORT ESR-9414 Qualification Type Testing of Amphenol Corporation s 2M805 Series Connector QUALIFICATION TEST SUMMARY REPORT ESR-9414 Qualification Type Testing of Amphenol Corporation s Connector PREPARED BY: Patrick Cole Design Engineer AMPHENOL CORPORATION Aerospace Operation 40-60 Delaware

More information

LCA717STR. Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION

LCA717STR. Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Single-Pole, Normally Open OptoMOS Relay Parameter Ratings Units Blocking Voltage V P Load Current A rms / A DC On-Resistance (max. Features Very Low Maximum On-Resistance:. High Load Current: A 7V rms

More information

MFJ ENTERPRISES, INC.

MFJ ENTERPRISES, INC. Model MFJ-2912 INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel: 662-323-5869 Fax: 662-323-6551 VERSION

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output Voltage 4 Outputs to 28 Vdc 4 Wide Input Ranges (10-20Vdc, 18-36Vdc, 20-60Vdc, 36-72Vdc) 4 Excellent Line & Load Regulation 4 500 Vdc Output Isolation 4 Continuous Short

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS IM-450 Models 153 Programmable Step Attenuator This documentation may not be reproduced in any form, for any purpose unless authorized in writing by API / Weinschel,

More information

Model 626B01. Low Frequency Industrial ICP Accelerometer. Installation and Operating Manual

Model 626B01. Low Frequency Industrial ICP Accelerometer. Installation and Operating Manual Model 626B01 Low Frequency Industrial ICP Accelerometer Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour

More information

28 Volt input 2.7 AMP not recommended for new design

28 Volt input 2.7 AMP not recommended for new design Features 60 db attenuation typical at 500 khz Compliant to MIL-STD-461C CE-03 Compatible with MIL-STD-704 A-E 28 volt power bus 1 Fully qualified to Class H -55 C to +125 C operation Nominal 28 volt input

More information

Broadband performance with low reflection DC to 4 GHz provides low cost connector combined with high quality.

Broadband performance with low reflection DC to 4 GHz provides low cost connector combined with high quality. Amphenol RF 36 Connectors Description The name derives from SubMiniature B (the second subminiature design). Developed in the 1960 s, this sub miniature interface has snap-on coupling. Amphenol s connectors

More information

CPC1965G AC Solid State Relay

CPC1965G AC Solid State Relay AC Solid State Relay Parameter Rating Units AC Operating Voltage 26 V rms Load Current 1 A rms On State Voltage Drop 1.6 V rms (at I L = 1A rms Features Load Current up to 1A rms 6V P Blocking Voltage

More information

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå From all of us at Resolution AV, thank you for choosing the Opus 21 s30 amplifier. We went to great lengths to design and produce an integrated

More information

Model 935A Current Source Operation Manual

Model 935A Current Source Operation Manual Model 935A Current Source Operation Manual Arbiter Systems, Inc. Paso Robles, CA 93446 U.S.A. ii Description This manual is issued for reference only, at the convenience of Arbiter Systems. Reasonable

More information

PS1201 AC Power Switch

PS1201 AC Power Switch AC Power Switch Parameter Rating Units AC Operating Voltage 12 V rms Load Current 1 A rms On-State Voltage Drop (I L =1A rms 1.2 V rms Features Load Current up to 1A rms (3A rms with heat sink Blocking

More information

DUAL LEVELAR. Two Channel Tube Compressor/Leveling Amplifier

DUAL LEVELAR. Two Channel Tube Compressor/Leveling Amplifier DUAL LEVELAR Two Channel Tube Compressor/Leveling Amplifier USER S GUIDE Introduction Thank you for purchasing the Dual Levelar and congratulations! You now own one of the most sophisticated pieces of

More information

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free 2001A 200KHz Function Generator Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WARRANTY Global Specialties

More information

QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400

QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400 QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400 RF Connectors Technical Data Sheet PE44978 Configuration QN Male Connector 50 Ohms Straight Body Geometry Features Max Operating

More information

Signal Transformer. Standard and Custom Power Transformers

Signal Transformer. Standard and Custom Power Transformers Standard and Custom Power Transformers The Signal Way of Doing Business (Often imitated, but NEVER equalled) At, we are committed to providing the highest grade magnetics for customers who demand total

More information

Amphenol RF- BNC Connector Series

Amphenol RF- BNC Connector Series Page 1 of 7 enter part number Products 7/16 1.0/2.3 1.6/5.6 AMC BNC / RP-BNC C FAKRA SMB FME HN MCX Mini-UHF Mini 75 Ohm SMB MMCX Precision (APC) QDS QMA QWS SC SlimLine BNC SMA / RP-SMA SMB SMC SMP TNC

More information

SPB-8 Features. Using the SPB-8/E. Introduction

SPB-8 Features. Using the SPB-8/E. Introduction SPB-8 Features The Pedal Board is a solid, nonslip base for pedal effects that lets you leave everything powered up and patched together as you like it Toroidal transformer for ultra low-noise performance

More information

Angular Rate Sensor. Owner's Manual

Angular Rate Sensor. Owner's Manual Angular Rate Sensor Owner's Manual Part Number: ARS-C132-1A WATSON INDUSTRIES, INC. 3041 MELBY ROAD EAU CLAIRE, WI 54703 Phone: (715) 839-0628 FAX: (715) 839-8248 email: support@watson-gyro.com 1 Table

More information

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OWNER S MANUAL Model 5100F RF POWER AMPLIFIER 0.8 2.5 GHz, 25 Watts Ophir RF 5300 Beethoven Street Los Angeles, CA 90066

More information

Broadband Step-Up Transformer. User Manual

Broadband Step-Up Transformer. User Manual Broadband Step-Up Transformer User Manual 990-1930 09/2004 Introduction Introduction About this unit The APC Step-Up Transformer provides 220 V power from 60 VAC Broadband cable systems. Safety Electrical

More information

Distribution Amplifiers 1

Distribution Amplifiers 1 Distribution Amplifiers 1-30dB PUT 49-750 MHz 43 db GA POWER DOUBLED P/N: 1002705 REVERSE GA M MAX DESCRIPTION The R.L. DRAKE models DA8642, DA8632,, and DA7533, are broadband distribution amplifiers designed

More information

Precision has the presence to provide the magnetics you need.

Precision has the presence to provide the magnetics you need. Precision has the presence to provide the magnetics you need. 1 Applications are the core of every Precision product Automation, motion, and motor controllers Sensors and measurement instruments Industrial

More information

Ultra Wide Band Low Noise Amplifier GHz. Electrical Specifications, TA = +25⁰C, With Vg= -5V, Vcc = +4V ~ +7V, 50 Ohm System

Ultra Wide Band Low Noise Amplifier GHz. Electrical Specifications, TA = +25⁰C, With Vg= -5V, Vcc = +4V ~ +7V, 50 Ohm System Ultra Wide Band Low Noise Amplifier 0.5 46GHz Parameter Min. Typ. Max. Min. Typ. Max. Units Frequency Range 0.5 20 20 46 GHz Gain 13 13 db Gain Variation Over Temperature (-45 ~ +85) ±3 ±2 db Noise Figure

More information

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver Copyright 2005, American Fibertek, Inc. 1020JD Table of Contents Functional Description...3 Installation...3 Power Source...3 Power Connection...3

More information

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product

More information

CERAMIC EMI-RFI FILTERS

CERAMIC EMI-RFI FILTERS Pi (60 db/ecae) AC-RATE CERAMIC EMI-RFI FITERS Pi (60 db / ECAE) 0.069 IA. HOE (2 PACES) 0.250-28 UNF -2A TH. 0.125 x 0.062 SOT (2 PACES) 0.312-24 -UNF 2A TH. 0.400 ± 0.016 0.670 ± 0.015 TH 0.180 ACROSS

More information

EMC Feedthrough Capacitors

EMC Feedthrough Capacitors EMC Feedthrough Capacitors Series/Type: B85121 The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments

More information

Assistive Listening Systems. RX-6 User s Guide

Assistive Listening Systems. RX-6 User s Guide Assistive Listening Systems RX-6 User s Guide Page ii RX-6 User s Guide Copyright Information Contents Introduction 1 Controls 2 Installing Batteries 3 Operation 3 Tuning the RX-6 4 Changing Preset Channels

More information

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas Model 3101, 3102 and 3103 Conical Log-Spiral Antennas MANUAL EMC TEST SYSTEMS, L.P. SEPTEMBER 2002 EMC Test Systems, L.P. reserves the right to make changes to any products herein to improve functioning,

More information

Instruction Manual Bandpass Cavity Filters 6 5/8 and 10 Diameter

Instruction Manual Bandpass Cavity Filters 6 5/8 and 10 Diameter Instruction Manual Bandpass Cavity Filters 6 5/8 and 10 Diameter Manual Part Number 7-9145 8625 Industrial Parkway, Angola, NY 14006 Tel: 716-549-4700 Fax: 716-549-4772 sales@birdrf.com www.birdrf.com

More information

Broadband Current Probe Series Operation Manual

Broadband Current Probe Series Operation Manual Broadband Current Probe Series Operation Manual 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 OPERATING INSTRUCTIONS 5 FORMULAS 6 MAINTENANCE 7 WARRANTY 8 2 INTRODUCTION CURRENT PROBE SPECIFICATIONS

More information

SC6015 DATA SHEET. BNC Female Bulkhead Connector Crimp/Solder Attachment For.100 inch, RG316, RG174, RG188, LMR-100, LMR-100A, LMR-100-FR Cable

SC6015 DATA SHEET. BNC Female Bulkhead Connector Crimp/Solder Attachment For.100 inch, RG316, RG174, RG188, LMR-100, LMR-100A, LMR-100-FR Cable BNC Female Bulkhead Connector Crimp/Solder Attachment For 100 inch, RG316, RG174, RG188, LMR-100, LMR-100A, LMR-100-FR Cable BNC female bulkhead connector with crimp/solder attachment for 100 inch, RG316,

More information