1 Ultrafast Systems 23 Product Catalog Superior Reliability & Performance

2 Ultrafast Systems Applications: and Probe Studies Time-domain Spectroscopy Surface Sum Frequency Generation EUV and X-ray Generation Attosecond Pulse Generation Terahertz Generation and Studies Time-resolved Raman Spectroscopy Multiphoton Microscopy (MPE) SHG/CARS/SRS/STED Microscopy Non-linear Material Modification Quantum Control Experiments Superior Reliability & Performance

3 Ultrafast Systems of Better Ultrafast, Every Day. s Welcome to the dynamic world of ultrafast lasers. This catalog covers the most comprehensive range of ultrafast products available anywhere from femtosecond oscillators to terawatt amplifiers, from pump lasers to autocorrelators. The unparalleled range of products guarantees that you can always chose the best laser device to match your experimental needs. Our extensive and ever-growing portfolio enables you to start your work with a simple modelocked oscillator and later on expand your fast moving research with ultrafast amplifiers, parametric devices and sophisticated accessories. We understand that before making any important buying decision you talk with other ultrafast researchers. We are confident that every Coherent user will tell you that our products are reliable, high-performance, user-friendly, and designed to deliver consistent results, day after day. When you select any of the products in this catalog, you will be building a strong foundation for your scientific instrumentation, ready to be expanded as your requirements evolve. The investments that you make now will continue to deliver valuable results for many years to come and wherever your research takes you. Finally, be assured that the exceptional performance of our products is backed by a highly specialized global support organization. Wherever a Coherent ultrafast product is deployed, our team of scientific field service engineers will be there to support it. So, no matter what type of research you are doing or where you are located, we provide you with the best performance, the broadest portfolio and the most comprehensive technical support. This is how we fulfill our promise to deliver you - Better Ultrafast, Every Day. Toll Free: (8) Tel: (48) Superior Reliability & Performance

4 Ultrafast Product and We offer an extensive portfolio of ultrafast oscillator products to choose from. This diagram summarizes the range and also indicates the compatibility of the various available products. For example, the Synchrolock-AP accessory is compatible with the Mira and Vitara, but incompatible with the Vitesse and Chameleon. Similarly, the Pulse Switch is compatible with the Mira-9, but incompatible with the Mira-HP. Please refer to the specifications on the individual product pages and the accessory compatibility charts on page 73 for more details. If you still have questions regarding specifications of product compatibility, please call or us. of Verdi W to 2W Verdi 5W to 2W Mira-HP Femto/Pico/Dual Mira-9 Femto/Pico/Dual Vitara Vitesse Chameleon s Synchrolock-AP Pulse Compressors SPO-I, SPO-II, CPC-II Pulse Switch Synchrolock-AP Pulse Compressors SPO-I, SPO-II, CPC-II Carrier-Envelope Phase (CEP) Stabilizer Pulse Picker Pulse Picker Harmonics Generators Harmonics Generators Mira-OPO Mira-OPO DFG Mira-OPO Mira-OPO DFG Chameleon Compact OPO-Vis 2 Superior Reliability & Performance tech.sales@coherent.com

5 Ultrafast Product s and Our ultrafast amplifier portfolio is the most extensive available. We offer amplified pulse energies from 4 µj to mj and repetition-rates from Hz to 3 khz. The diagram below summarizes the range available and also indicates the compatibility of the various products. Please note that not all oscillator versions are compatible with all versions of our amplifiers. Please refer to the specifications on the individual product pages for more details. If you still have questions regarding specifications or product compatibility, please call or us. Verdi W to 2W Verdi 5W to2w One-Box Libra, 5, or khz Evolution Vitesse/ Vitara of Mira-HP Femto/Pico/Dual Mira-9 Femto/Pico/Dual Vitara Vitesse Chameleon s RegA Single-Shot to 5 khz Verdi Legend Elite HE+, 5, and khz Evolution Legend Elite Duo HE+, 5, and khz Evolution Legend Cryo PA Evolution Hidra Hz Hz Nd:YAG s OPAs for RegA OPAs, Harmonics and Other OPAs for Legend, Libra, Hidra Harmonics Other OPA 94/945 and 98/985 OPerA Solo Harmonic Generator Systems (HGS) Carrier-Envelope Phase (CEP) Stabilizer DFG 98/985 TOPAS/TOPAS-4/ TOPAS-Prime Second Harmonic Bandwidth Compressor (SHBC) Single-Shot Autocorrelator (SSA) Toll Free: (8) Tel: (48) Superior Reliability & Performance 3

6 Ultrafast Systems of Ultrafast Systems of Ultrafast Product and 2 s and 3 Verdi G-Series 6-7 Evolution 8- s Mira Mira-HP 6-7 Vitara 8-9 Vitesse 2-2 Chameleon Ultra Chameleon Vision and Vision-S Chameleon Compact OPO and OPO-Vis 28-3 Mira-OPO Harmonic Generation for Ultrafast 36 Pulse Picker 37 Pulse Switch for Mira Compact Pulse Compressor (CPC-II) 4 Pulse Compressors (SPO-I/SPO-II) 4 Synchrolock-AP CEP Stabilizer for Vitara s Legend Elite HE+/Legend Elite Duo HE Legend Elite Cryo PA 5-5 Libra Hidra RegA 9/ Superior Reliability & Performance tech.sales@coherent.com

7 Ultrafast Systems of OPerA Solo TOPAS 6-6 TOPAS-Prime SHBC/TOPAS Harmonic Generator Systems (HGS) 66 Single-Shot Autocorrelator (SSA) 67 OPA 94/945 and 98/ DFG 98/ Legend Elite CEP 7-7 Matrix of Recommendations 72 of 73 Ultrafast How to Contact Us 76 Visit the Coherent Website Inside Back Cover s Toll Free: (8) Tel: (48) Superior Reliability & Performance 5

8 Verdi G-Series Low-Noise, Green of s The Verdi G-Series is a revolutionary green pump laser that uses a semiconductor chip as the active medium in place of a conventional laser crystal. This chip has a thickness of only a few microns and is pumped by a diode laser, to generate an infrared beam at a wavelength determined by the chip properties. In all the Verdi G models, the oscillating wavelength is 64 nm intracavity doubled to produce a 532 nm green output beam. This so-called Optically-ed Semiconductor (OPSL) technology, patented and unique to Coherent, offers numerous benefits. The very short upper state lifetime eliminates the well known green noise problem encountered with other multi-frequency solid-state lasers; this results in a noise performance superior to all other green lasers and enabling the most noise-sensitive applications like CEP stabilization. The absence of thermal lensing in the active medium allows adjusting the output power between 25 mw and the maximum value without changes in beam parameters. The inherently smaller and simpler design is coupled with the well-established advantages of the entire Verdi family PermAlign technology and vertically integrated pump diode supply to enable a new laser platform that is easily scalable in power and extremely reliable. OPSL technology has been proven for over years and in over 3, worldwide installations of various models operating at many different wavelengths and power levels. Verdi G and other OPSL models are also integrated in the Vitara ultrafast oscillator family. RMS Noise (%) Verdi G RMS Noise ( Hz to MHz) Output Power (W) M 2, Ellipticity and Divergence (mrad) Verdi G Invariant n ant Beam Parameters vs s. Power M 2 Ellipticity Divergence Diameter (mm) nm Power (W) Beam Diameter (mm) 6 Superior Reliability & Performance tech.sales@coherent.com

9 Verdi G-Series Low-Noise, Green Key Advantages 2W to 2W specified power at 532 nm Adjustable output power without changes in beam parameters Absence of green noise enables <.2% rms noise performance 2-Year warranty and low cost of ownership Established PermAlign and vertically integrated diode supply OPSL proven reliability with over 3, units installed Easy set up and operation of Specifications Electrical Specifications Environmental Conditions Verdi G2/G5/G7/G8 G G2/G5/G8/G2 Wavelength (nm) 532 ±2 Pulse Format Spectral Purity (%) >99 Output Power (W) 2, 5, 7, , 5, 8, 2 2 Spatial Mode CW TEM Beam Quality <. Beam Circularity 3. ±. Beam Waist Diameter (mm)(fw, /e 2 ) 2.25 ±% Beam Divergence (mrad)(fw, /e 2 ) <.5 Beam Waist Location 4 (m) ±.5 Beam Pointing Stability 5 (μrad/ C) <2 Horizontal Beam Position Tolerance 6 (mm) ±<. Vertical Beam Position Tolerance 6 (mm) ±<. Polarization Ratio Linear, >: Polarization Direction Vertical, ±5 Noise (%, rms)( Hz to MHz) <.2 Power Stability 7 (%)(pk-pk) ±< Warm-Up Time (minutes) < CDRH Compliant Operating Voltage (VAC) to 24 Frequency (Hz) 5 to 6 Power Consumption (W) 5 (2W, 5W), 6 (7W, 8W) 7 (2W), 25 (5W), 5 (8W, 2W) Ambient Temperature ( C) Operating to 4 Non-Operating - to 6 Relative Humidity (%) 5 to 95 8 CE Marking IEC 6-/EN 6- Dimensions (L x W x H) Head 9 28 x 56 x 85 mm 24 x 98 x 68 mm (.6 x 6.4 x 3.35 in.) (8.43 x 3.86 x 2.68 in.) Benchtop Power Supply 36 x 229 x 6 mm 46 x 236 x 7 mm (4.22 x 9. x 6.29 in.) (6. x 9.3 x 6.75 in.) Cables (laser head to controller) Optical parameters measured at the output plane of the laser head, unless noted all parameters valid at the nominal output power and for the lifetime of the unit. 2 This product is offered in several output power versions. The output power can be adjusted down to 25 mw (G2-G) and 75 mw (G2-G2). 3 Circularity defined as vertical diameter divided by horizontal diameter. Yes 3m ( ft.) 4 Negative value corresponds to a location inside head. 5 After 2-hour warm-up. 6 Measured at the output window. 7 Measured over 8 hrs. 8 Non-condensing. 9 Back connector not included in laser head length dimension. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 7

10 Evolution Q-Switched, Nd:YLF Green of s The Evolution family of frequency-doubled Nd:YLF diode-pumped lasers provides the mode quality, stability and range of power levels ideally suited for pumping Ti:Sapphire ultrafast amplifiers with repetition-rates in the range of khz to khz. Evolution is available in four versions: 5W, 3W, 45W and 75W of average power when rated at 5 khz. The lifetime of the Evolution s pump diodes routinely exceeds, hours and the highly efficient pumping lowers the thermal load on the Nd:YLF rod. These two elements are key to the Evolution s reliability, power stability, low noise and beam quality. Surprisingly compact, the Evolution laser head is built in a rugged, monolithic, thermally-stabilized enclosure for reliable, alignment-free operation. The laptop computer supplied with the system includes a comprehensive LabVIEW user interface that provides a wide range of control, diagnostics and performance-monitoring features. Like our Verdi CW pump laser, the Evolution is the industry s best-selling laser in its class and is used to pump more amplifiers than any other Q-switched pump laser in the world. With pulse energies in excess of 45 mj at khz, the Evolution-HE provides the optimum solution for pumping high power amplifiers, as well as the high pulse energy required in such emerging applications as semiconductor annealing, materials processing and flow visualization. LabVIEW GUI 8 Superior Reliability & Performance tech.sales@coherent.com

11 Evolution Q-Switched, Nd:YLF Green Key Advantages Optimized for pumping the Legend Elite series of ultrafast Ti:Sapphire amplifiers Available in four versions: 5W, 3W, 45W, and 75W (High Energy) Double Pulse Option available for the 5W and 3W versions khz to khz repetition-rates Excellent beam quality Typically <.4% rms pulse-to-pulse energy stability Water-cooled, monolithic laser head provides superior mechanical and thermal stability Side or front beam exit port options User-friendly LabVIEW-based control software diode lifetimes average in excess of, hours High Energy (HE) model features two Nd:YLF gain modules, for thermal lens compensation over a broad operating range of s 3 Typical Evolution-3 Power Stability 6 Typical Evolution-HE Power Stability Power at 527 nm (W) Dev. (%) Mean Power = 25.2W Std. Dev. =.3% Time (hours) Power at 527 nm (W) Dev. (%) Mean Power = 5.9W Std. Dev. =.6% 2 24 Time (hours) Time (hours) Time (hours) 24 Toll Free: (8) Tel: (48) Superior Reliability & Performance 9

12 Evolution Q-Switched, Nd:YLF Green of s Specifications Evolution-5 Evolution-3 Evolution-45 Evolution-HE Wavelength (nm) Pulse Repetition-Rate (khz) to (factory set) Average Output Power (W) 2 at khz 2 at khz 28 at khz 45 at khz 5 at 5 khz 3 at 5 khz 45 at 5 khz 75 at 5 khz 5 at khz 3 at khz 45 at khz 75 at khz Energy-Per-Pulse (mj) 2 at khz 2 at khz 28 at khz 45 at khz 3 at 5 khz 6 at 5 khz 9 at 5 khz 5 at 5 khz.5 at khz 3 at khz 4.5 at khz 7.5 at khz Typical Pulse Width (nsec)(fwhm) <3 at khz <25 at khz <25 at khz <5 at khz Pulse-to-Pulse Energy Stability (% rms) <.5 <.5 Polarization Ratio Horizontal, >: Horizontal, >: Spatial Mode Multimode Multimode Beam Divergence (mrad)(full angle) < <8 Beam Circularity (%) >8 >8 Nominal Beam Diameter at Output Window (mm)(/e 2 ) 3 3 Operating Voltage (VAC) (±%, single-phase) to 24 2 to 24 Chiller 23, 5 Hz (Europe) 23, 5 Hz (Europe), 6 Hz, 6 Hz Line Frequency (Hz) 5 to 6 5 to 6 Power Consumption (kw).4 typ.; o.6 max..8 typ.; max..8 typ.; max..75 typ.;.9 max. Chiller.9 max..8 max..8 max..8 max. Weight 24 kg (53 lbs.) 4 kg (88 lbs.) Power Supply 4 kg (3 lbs.) 4 kg (3 lbs.) Chiller 44 kg (97 lbs.) 55 kg (22 lbs.) 55 kg (22 lbs.) 55 kg (22 lbs.) Umbilical 2 kg (4.5 lbs.) 2 kg (4.5 lbs.) Umbilical Length 3m ( ft.) Warm-Up Time (minutes)(typical) < from standby mode <3 from cold start Bore-Sight Accuracy (unit-to-unit).5 mm and ± mrad Referenced to mounting features on laser head Other rep-rates upon request. Superior Reliability & Performance tech.sales@coherent.com

13 Evolution Q-Switched, Nd:YLF Green Typical Evolution-3 Beam Profile of Far-Field Beam Profile Measured at Focus of 5 mm Focal Length Lens FWHM x = 47 µm FWHM y = 58 µm 6 Evolution HE Lifetest Data Power (W) , 4, 6, 8,, 2, Time (hours) s Toll Free: (8) Tel: (48) Superior Reliability & Performance

14 Mira-9 Ultrafast Femtosecond/Picosecond Ti:Sapphire of s More Mira-9 oscillators are in use today than any other modelocked Ti:Sapphire laser system. The Mira-9 combines simplicity and reliability in an innovative design to produce the most powerful and versatile ultrafast laser system available. The innovative design of the Mira-9 system makes switching between continuous-wave, picosecond and femtosecond operation simple, while passive Kerr lens modelocking provides greater ease-of-use and reliability. Our built-in Optima control and diagnostics system enables easy adjustment of the output wavelength, pulse width and power. Optima features a fast photodiode, relative power monitor, ß-lock, CW detector, humidity sensor and an automatic starter. A wide range of accessories is available for the Mira-9. These allow operation at lower repetitionrate (Pulse Picker), higher pulse energy (Pulse Switch cavity dumper), shorter wavelengths (Harmonic Generator, Mira-OPO-VIS), longer wavelengths (Mira-OPO-IR), and the ability to deliver a transformlimited pulse at the sample (SPO-I, SPO-II, CPC-II). Output Power (W) Typical X-Wave Power Curves for Verdi-pumped Mira Optima 9-F W Verdi pump 8W Verdi pump 5W Verdi pump Output Power (W) Typical X-Wave Power Curves for Verdi-pumped Mira Optima 9-P W Verdi pump 8W Verdi pump 5W Verdi pump Wavelength (nm) Wavelength (nm) 2 Superior Reliability & Performance tech.sales@coherent.com

15 Mira-9 Ultrafast Femtosecond/Picosecond Ti:Sapphire Key Advantages Simple, stable Kerr lens modelocking for ease-of-use and reliability Femtosecond, picosecond and continuous-wave operation X-Wave single optics set allows wavelength tuning from 7 nm to nm Verdi 532 nm pump sources between 5W and 2W deliver diode-pumped stability and reliability Optima system provides advanced system monitoring and control Sealed purgeable enclosure results in higher reliability and full wavelength coverage Integrated pump steering optics make pump alignment easy Auxiliary CW cavity for general setup and continuouswave operation Options and Short pulse option: <7 fs Long pulse option: >5 ps 2nd, 3rd and 4th harmonic generation Mira-OPO synchronously-pumped OPO Pulse Picker Pulse Switch cavity dumper Synchrolock-AP SPO-I, SPO-II and CPC-II pulse compressors of s Specifications Mira Optima 9-F Mira Optima 9-P Mira Optima 9-D Output Power 2,3 Dual platform contains all Verdi-G5.75 hardware necessary for both Verdi-G8. femtosecond (-F) and Verdi-G.4 picosecond (-P) operation. Verdi-G2.6 Tuning Range 4 (nm) 7 to Pulse Width 2,5 <5 fs <2 ps <5 fs and <2 ps Repetition-Rate (MHz) 76, nominal Noise 6 (%) <. Stability 7 (%) <3 Beam Diameter 8 (mm).8 Beam Divergence 9 (mrad).7 Spatial Mode TEM Polarization Horizontal Physical Dimensions. x 38. x 9.7 cm (43.75 x 5 x 7.75 in.) Specifications apply only with Coherent pump lasers. 2 At 8 nm. 3 For other pump power call factory. 4 Wider coverage possible with short wave or extended long wave optics sets. 5 Based on sech 2 deconvolution of.65 times autocorrelation width. Pulse width is <3 fs across specified tuning range in fs mode. 6 Measured rms in a Hz to 2 MHz bandwidth. 7 Power drift in any two-hour period after warm-up when crystal s cooling water is maintained at ±. C. 8 /e 2 diameter (±.2 mm) at exit port. 9 Full angle divergence (±.3 mrad) at exit port. Typical measured M 2 value is.. Toll Free: (8) Tel: (48) Superior Reliability & Performance 3

16 Mira-9 Internal Cavity Design of input A 9-F high reflector M7 9-P fold mirror M8 GVD prism P translation stage input B Independent pump beam translation and angle controls s 9-F fold mirror M6 input C GVD prism P2 GVD prism P2 external control focus lens Cavity mirror M4 Ti:Sapphire crystal mount 4 Superior Reliability & Performance tech.sales@coherent.com

17 Mira-9 Internal Cavity Design 9-P Gires-Tournois Interferometer (GTI) with b-lock 9-P fold mirror M Cavity length thermal compensation mechanism CW cavity end mirror M9 of CW detector CW detector galvo Power monitor detector Fast photodiode sync output detector s Detector block pick-off Starter mechanism Cavity mirror M5 Fold mirror M3 Birefringent filter tuning element Saturable absorber aperture with width and translation controls X, Y and length control of output coupler mirror M Beam path for femtosecond cavity Beam path extension for picosecond cavity Beam path extension for CW cavity Toll Free: (8) Tel: (48) Superior Reliability & Performance 5

18 Mira-HP High Power Ultrafast Ti:Sapphire of s The femtosecond/picosecond Mira-HP is the world s most powerful commercial ultrafast Ti:Sapphire oscillator. Conservatively specified at 3.5W average power in femtosecond mode, the Mira-HP-F typically delivers power in excess of 4W at 8 nm. Designed specifically to be pumped by our Verdi G8 laser, Mira-HP oscillators deliver high power across the entire Ti:Sapphire tuning curve. Like the Mira 9, the Mira-HP features the built-in Optima control and diagnostics system for greater ease of use and high reliability. Typical Mira-HP Beam Profile 5 Typical X-Wave Power Curve for Verdi G8 ed Mira-HP-F 4 Typical X-Wave Power Curve for Verdi G8 ed Mira-HP-P Output Power (W) Output Power (W) Wavelength (nm) Wavelength (nm) 6 Superior Reliability & Performance tech.sales@coherent.com

19 Mira-HP High Power Ultrafast Ti:Sapphire Key Advantages Simple, stable Kerr lens modelocking for greater ease of use and reliability X-Wave single optics set supports wavelength tuning from less than 7 nm to more than nm Optima system control and diagnostics package is integral to system Purgeable enclosure improves reliability and provides full wavelength coverage Integrated pump steering optics for easy pump alignment Optional pumping beam directions allow wider choice of optical table layouts Auxiliary CW cavity for ease of general setup and continuous-wave operation Options and Mira-OPO synchronously-pumped OPO 2nd, 3rd and 4th harmonic generation Pulse Picker Synchrolock-AP SPO-I, SPO-II and CPC-II pulse compressors of Specifications Mira-HP-F Mira-HP-P Mira-HP-D Output Power 2 (W) >3.5 (>4 typ.) >3. (>3.2 typ.) Dual platform contains all hardware necessary for both femtosecond (-F) and picosecond (-P) operation. Pulse Width 2,3,4 <3 fs <2 ps <3 fs and <2 ps Tuning Range (nm)(x-wave Optics) 7 to Repetition-Rate (MHz)(nominal) 76 Noise 5 (%) <. Stability 6 (%) <3 Beam Diameter 7 (mm).8 Beam Divergence 8 (mrad).5 Spatial Mode 9 TEM Polarization Horizontal Physical Dimensions. x 38. x 9.7 cm (43.75 x 5 x 7.75 in.) Specifications apply only with Coherent Verdi-G8 pump lasers. 2 At 8 nm. 3 Based on sech 2 deconvolution of.65 times autocorrelation width. Pulse width is <6 fs across specified tuning range in fs mode. 4 In fs mode, the pulses are typically.5x the transform limit and so can be further compressed in an external compressor. 5 Measured rms in a Hz to 2 MHz bandwidth. 6 Power drift in any two-hour period after warm-up when crystal s cooling water is maintained at ±. C. 7 /e 2 diameter (±.2 mm) at exit port. 8 Full angle divergence (±.3 mrad) at exit port. 9 Typical measured M 2 value is.. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 7

20 Vitara Automated, Hands-Free Ultrashort Pulse Ti:Sapphire of s Vitara is the new industry standard for hands-free, integrated, ultra-broadband, flexible ultrafast lasers. Representing the culmination of 2 years of in-house expertise with Kerr Lens mode-locking and thousands of clean-room manufactured, industrial-grade ultrafast lasers, the Vitara family satisfies the most sophisticated requirements for amplifier seeding, terahertz generation, attosecond studies, quantum control experiments, non-linear imaging and spectroscopy applications. Models within the Vitara family range from an ultrabroadband version generating pulses shorter than fs, a tunable version with user-adjustable bandwidth and sub-2 fs compressed output, a high power version providing Watt-class average power and a version tailored for seeding ultrafast amplifiers. All models of the Vitara platform provide hands-free operation guaranteed by Coherent s proprietary clean manufacturing practices, our unique Optically ed Semiconductor (OPS) pump lasers and a suite of automated controls. In addition to its exquisite flexibility, Vitara satisfies the most sophisticated requirement in Carrier to Envelope Phase (CEP) stabilization and external source synchronization thanks to its broad range of accessories. Designed as a long-lasting and expandable ultrafast laser platform, Vitara provides reliable hands-free operation even with the most demanding applications and environments. Modelocked Power (mw) Vitara-T and Vitara-T-HP Typical Power vs. Bandwidth at 8 MHz Vitara T Vitara T HP Bandwidth FWHM (nm) Pulse Intensity Transform Limit Measured Pulse Phase Vitara-UBB Typical Pulse Duration Time (fs) 9 fs Measured Pulse Duration Phase (rad) 8 Superior Reliability & Performance tech.sales@coherent.com

21 Vitara Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Key Advantages Automated for hands-free, reliable operation Computer controlled bandwidth Computer tunable center wavelength PowerTrack active optimization <8 fs to >3 fs pulsewidth capability Low noise Integrated Verdi G pump laser Compact footprint Options and Carrier-Envelope Phase (CEP) Stabilizer Pulse synchronization Synchrolock-AP Integrated, calibrated spectrometer Compact Pulse Compressor CPC-II Second Harmonic Generator Factory configurable for use with internal or external pump laser of Specifications,2 Electrical and Cooling Requirements Vitara-T Vitara-T-HP Vitara-S 7 Vitara-UBB Power (mw) at minimum specified bandwidth >525 > at 6 nm bandwidth >45 > at maximum specified bandwidth >425 >8 > >55 Bandwidth (nm) 3 to 25 4 to >7 (fixed) <8 to >22 at FWHM at FWHM at FWHM at -db Tuning Range (nm) at minimum specified bandwidth 755 to to at 6 nm bandwidth 765 to to at nm bandwidth 79 to to Uncompressed Pulsewidth 3 (fs) <2 (typically <5) <2 (typically <5) - - Compressed Pulsewidth 3 (fs) <2 <5 <2 < 8 with External Compressor (not included) RMS Noise 4 (%) <.5 <.5 <.5 <. Power Stability 5 (%) ±.5 ±.5 ±.75 ±.5 Repetition-Rate (MHz)(standard) M 2 (average of X & Y) <.3 <.3 <.3 <.3 Beam Diameter 6 (mm) Beam Divergence (mrad) < < <.5 < Polarization Horizontal Horizontal Horizontal Horizontal Voltage to 24 Current Max. (A) 5 Line Frequency (Hz) 5 to 6 Cooling Head Dimensions (L x W x H) Beam Height Specifications subject to change. 2 Specifications apply at 8 nm and 8 MHz rep. rate unless otherwise stated. 3 At max. bandwidth and measured with FC Spider (APE GmbH). 4 Measured from Hz to MHz. 5 Measured over 2 hrs. after 3 min. warm-up at constant environmental temperature. 6 Average /e 2 diameter measured at output. 7 Center wavelength of output from Vitara-S is fixed at 8 ± nm. 8 <8 fs available on request. 9 Can be factory set between 65 to 95 MHz. Closed-cycle chiller 69.6 x x 62.4 mm (24. x 6.8 x 6.4 in.) excluding handles 2.6 mm (4.75 in.) s Toll Free: (8) Tel: (48) Superior Reliability & Performance 9

22 Vitesse Compact Turnkey Modelocked Ti:Sapphire of s The Vitesse family of one-box modelocked Ti:Sapphire oscillators features an integrated Verdi pump laser in a truly hands-off sealed laser head design. Ideally suited for seeding ultrafast amplifiers, or as the laser source in a wide range of industrial applications, all Vitesse versions use PermAlign solder-bonded optics for high reliability and intracavity chirped optics for dispersion compensation. Vitesse 8 This fixed-wavelength version operates at 8 nm and is available with Verdi 2W or Verdi 5W pump lasers. System control is via the front panel of the power supply or from an external computer. The Vitesse 8 6. is particularly suitable as a seed for ultrafast amplifiers, such as our Legend Elite systems and our RegA 9/95 regenerative amplifier. Vitesse Duo This special Duo version serves as an integrated seed and green pump source for our RegA 9/95 regenerative amplifier. In this configuration a W Verdi CW laser internally pumps the Vitesse Ti:Sapphire oscillator while externally pumping the RegA. The combined two-box Vitesse Duo and RegA 9/95 system is a compact, economical, all-solid-state solution for high repetition-rate, ultrafast amplification. Vitesse 8-5 Lifetime: power required to maintain constant output power from Vitesse Green Power (W) Months 2 Superior Reliability & Performance tech.sales@coherent.com

23 Vitesse Compact Turnkey Modelocked Ti:Sapphire Key Advantages Compact, rugged packaging based on PermAlign solder-bonded optics technology Turnkey, hands-off operation with automatic modelocking Up to 75 mw average power at 8 MHz repetition-rate Less than fs pulse width Active pointing control for long-term alignment stability Light-loop stabilization for long-term power stability Verdi pump laser provides proven reliability and low-maintenance operation Replaceable pump diode modules in power supply of Specifications Vitesse 8-2 Vitesse 8-5 Vitesse Duo- Average Power (mw) >2 >75 > Wavelength (nm) 8 Bandwidth 2 (nm) > Pulse Width 3 (fs) < Repetition-Rate 4 (MHz) 8 Power Stability 5 (%) ± Noise 6 (%)(rms) <. Beam Diameter 7 (mm) Beam Divergence 8 (mrad) <.2 <. <.4 M 2 <.2 Polarization Horizontal, >: Voltage (V) 9 to 25 Current Max. (A) 3 at VAC Frequency (Hz) 47 to 63 Cooling 9 Conductively-cooled to a heat sink with a closed-cycle chiller Nominal center wavelength ± nm. 2 Full width at half maximum. 3 Based on sech2 deconvolution of.65 times autocorrelation width. 4 Nominal repetition-rate ±.8 MHz. 5 Measured over 2 hours after 5-minute warm-up. 6 Measured from Hz to MHz. 7 /e 2 at exit port, nominal beam diameter ±.5 mm. 8 Full angle (/e 2 ). 9 Dependent on operational environment. The Vitesse Duo is a special configuration of the Vitesse that serves as an integrated seed and pump source for the Coherent RegA 9/95 regenerative amplifier. It has dual output beams at 532 nm and 8 nm. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 2

24 Chameleon Ultra Integrated, Automated and Widely Tunable Ti:Sapphire of s More Chameleon Ultra systems are used for Multi-Photon Excitation (MPE) Microscopy and other non-linear imaging techniques than any other laser. ed by the highest power green laser available on the market, Chameleon Ultra II delivers the highest power, the widest tuning range, the fastest tuning speed and the lowest noise of all commercially available Ti:Sapphire lasers. Its beam quality and pulse duration are specified to perfectly match your microscope or any other femtosecond experiment. Because of these capabilities, it is possible to image more dyes and fluorescent proteins, and to obtain deeper images more quickly than with any other laser. For example, the Chameleon Ultra II s 68 nm to 8 nm tuning range allows peak excitation of any marker from short-wavelength dyes such as Indo or Fura, to new proteins like mcherry as well as optimum native fluorescence excitation or SHG imaging. Every laser in the Chameleon Ultra family is compatible and has been tested with every inverted or upright MPE microscope on the market. In addition to the industry record, the integrated 8W Verdi pump laser provides the lowest optical noise and longest lifetimes available. Chameleon Ultra II Typical Power Power (W) Chameleon Ultra II Wavelength (nm) 22 Superior Reliability & Performance tech.sales@coherent.com

25 Chameleon Ultra Integrated, Automated and Widely Tunable Ti:Sapphire Key Advantages Sealed construction for hands-free operation Highest output power commercially available: Up to >3.5W Widest tuning range: Up to 4 nm Pulse width optimized for minimal broadening in microscope systems Simple menu-driven GUI or RS-232 operator interface On-board spectrometer with USB interface for actual wavelength monitoring PowerTrack active alignment and PermAlign manufacturing for long-term stability Ready for Chameleon Compact OPO pumping of Proprietary PowerTrack and PermAlign technologies ensure stable performance over the laser lifetime without any adjustments. The features of Chameleon Ultra combine to provide high throughput and quiet, reliable operation for thousands of hours, image after image. A broad range of accessories, including units for precompensation, harmonics generation, and OPO wavelength extension, enable more advanced studies where adjustable pulse duration and UV, visible or longer IR wavelengths are desirable. s Specifications Chameleon Ultra Chameleon Ultra I Chameleon Ultra II Average Power (W) >2.5 >2.9 >3.5 Tuning Range (nm) 69 to 2 69 to 4 68 to 8 Peak Power (kw) >2 >25 >3 Power Specifications >5 mw at 69 nm >6 mw at 69 nm >65 mw at 68 nm >.4W at 7 nm >.5W at 7 nm >.6W at 7 nm >2.5W at 8 nm >2.9W at 8 nm >3.5W at 8 nm >.4W at 92 nm >.45W at 92 nm >.6W at 92 nm >45 mw at 2 nm >45 mw at 2 nm >55 mw at 2 nm >3 mw at 4 nm >2 mw at 8 nm Tuning Speed 2 (nm/s) >35 >4 >4 Pulse Width,3 (fs) 4 Noise,4 (%) <.5 Output Power Stability 5 (%) <±.5 Spatial Mode (M 2 <.) TEM Beam Diameter,6 (mm).2 ±.2 Beam Ellipticity,7.9 to. Astigmatism (%) < Repetition-Rate (MHz) 8 Polarization Horizontal, >5: Pointing (μrad/nm) <.5 Head Physical Dimensions 65. x 37. x 9. cm (25.64 x 4.53 x 7.45 in.) Specified at peak of tuning range. 2 Average speed measured over entire tuning range. 3 Based on sech 2 deconvolution of.65 times autocorrelation width. 4 Measured rms in a Hz to 2 MHz bandwidth. 5 Power drift in any two-hour period with less than ± C temperature change after a one-hour warm-up. 6 /e 2 at exit port. 7 Ratio of major to minor /e 2 beam diameter at exit port. Toll Free: (8) Tel: (48) Superior Reliability & Performance 23

26 Chameleon Vision and Vision-S Integrated, Automated and Widely Tunable Ti:Sapphire of s The Chameleon Vision family has been designed to pre-compensate (pre-chirp) for the natural dispersion that occurs when femtosecond pulses pass through optical elements such as lenses. In some imaging applications, it may be useful to excite the sample with short pulses in order to maximize the efficiency of the non-linear process (two-photon excitation or harmonic generation). To satisfy this need, Chameleon Vision I and Vision II use the same ultrafast cavity design of the Chameleon Ultra family, with the addition of a built-in automated, pre-compensation unit. As a result, the pulse duration at the sample can always be optimized to match its time-bandwidth limited value (about 4 fs at 8 nm). Chameleon Vision-S has been designed for those users who, in addition to pre-compensation, also want to excite the sample with even shorter pulses, but still retain the widest possible tuning range. Short pulses maximize the ratio between peak power and average power, an advantage for those samples where linear (average power-based) damage dominates over non-linear (peak power-based) damage. Chameleon Vision-S fully satisfies this requirement by providing 75 fs pulses at the sample. Built-in pre-compensation supplies also an easy way to purposely change the pulse duration at the sample, to study of the interplay of peak power, average power and pulse duration on different samples. For example, by mismatching the pre-compensation, it is possible Chameleon Vision Family Typical Power Chameleon Vision Maximum Negative Dispersion Capability The shaded area represents the available dispersion range Average Power (W) Wavelength (nm) Chameleon Vision II Chameleon Vision I Negative Dispersion (fs 2 ) 5, 4, 3, 2,, Wavelength (nm) 24 Superior Reliability & Performance tech.sales@coherent.com

27 Chameleon Vision and Vision-S Integrated, Automated and Widely Tunable Ti:Sapphire Key Advantages Sealed construction for hands-free operation Choice of 4 fs and 75 fs pulses Automated pre-compensation with user-adjustable tables Highest average output power among pre-chirped lasers (Vision II) Highest peak power among pre-chirped lasers (Vision S) Widest tuning range available: 4 nm (Vision II) Widest range of dispersion pre-compensation ( to 47, fs 2 ) Simple menu-drive GUI or RS-232 operator interface for laser and pre-chirp management On board spectrometer with USB interface for wavelength and bandwidth monitoring PowerTrack active alignment and PermAlign manufacturing for long-term stability of to vary the pulse duration at the sample between the fully compensated value of 75 fs to chirped pulse durations of several hundreds of femtoseconds. All Chameleon Vision models incorporate our proprietary prism-based design, able to compensate the broadest range of GVD (Group Velocity Dispersion) using the smallest system footprint commercially available. The provided GVD compensation range is wide enough to eliminate the pulse broadening associated with the most sophisticated microscopes, like ones including complex objective lenses, modulators and other optical elements. Chameleon Vision I and II deliver the highest average power, the broadest tuning range, the fastest tuning speed and the lowest noise available on the market among Ti:Sapphire lasers with pre-compensation. Chameleon Vision S delivers the highest peak power at the sample, providing at the same time the broadest tuning range among automated short pulse Ti:Sapphire lasers designed for nonlinear imaging. This exceptional performance enables Chameleon Vision to easily manage pulse duration and excitation wavelength, providing brighter images and better sample viability. The broadly adjustable GVD compensation can be used to optimize image brightness even while pumping the OPO. The flexibility of the Vision family makes it ideal not only for microscopy but also for time-resolved spectroscopy and Terahertz studies. s Chameleon Vision-S Typical Peak Power Chameleon Vision-S Maximum Negative Dispersion Capability The shaded area represents the available dispersion range Peak Power (kw) Wavelength (nm) Negative Dispersion (fs²) 5, 4, 3, 2,, Wavelength (nm) Toll Free: (8) Tel: (48) Superior Reliability & Performance 25

28 Chameleon Vision and Vision-S Integrated, Automated and Widely Tunable Ti:Sapphire of s Specifications Chameleon Vision I Chameleon Vision II Tuning Range (nm) 69 to 4 68 to 8 Power Specifications - 5 mw at 68 nm 64 mw at 69 nm -.7 W at 7 nm.5w at 7 nm 2.5W at 8 nm 3.W at 8 nm 92 mw at 92 nm.35w at 92 nm 26 mw at 4 nm 4 mw at 4 nm - 8 mw at 8 nm Dispersion Compensation Range - to 47, fs 2 at 68 nm to 43, fs 2 at 69 nm - to 22, fs 2 at 8 nm to 22, fs 2 at 8 nm to, fs2 at 2 nm to, fs2 at 2 nm - to 9, fs2 at 8 nm Tuning Speed 2 (nm/s) >35 >4 Pulse Width,3 (fs) 4 Noise,4 (%) <.5 Output Power Stability,5 <±.5 Spatial Mode TEM (M 2 <.) Beam Diamater,6 (mm).2 ±.2 Beam Ellipticity,7.9 to. Astigmatism (%) < Repetition-Rate (MHz) 8 Polarization Horizontal >5: Pointing (µrad/nm) <8/ Operating Voltage (VAC) 9 to 25 (auto ranging) Chiller: Dimensions (L x W x H) 27 x 2 x 38 cm ( x 8 x 5 in.) Weight kg (25 lbs.) MRU Air Recirculator: Dimensions (L x W x H) 46 x 43 x 8.5 cm (8 x 7 x 3 in.) Weight 9 kg (2 lbs.) Specified at peak of tuning range. 2 Average speed measured over entire tuning range. 3 Based on sech 2 deconvolution of.65 times autocorrelation width. 4 Measured rms in a Hz to 2 MHz bandwidth. 5 Power drift in any two-hour period with less than ± C temperature change after a one-hour warm-up. 6 /e 2 at exit port. 7 Ratio of major to minor /e 2 beam diameter at exit port. 26 Superior Reliability & Performance tech.sales@coherent.com

29 Chameleon Vision and Vision-S Integrated, Automated and Widely Tunable Ti:Sapphire Specifications Chameleon Vision-S Tuning Range (nm) 69 to 5 Average Power at Peak (W) 2.3 Peak Power at Peak (kw) >38 Peak Power Specifications 6 kw at 69 nm 38 kw at 8 nm 25 kw at 92 nm 5 kw at 5 nm Dispersion Compensation Range to 43, fs 2 at 69 nm to 22, fs 2 at 8 nm to 9,5 fs 2 at 5 nm Tuning Speed 2 (nm/s) >25 Pulse Width,3 (fs) 75 Noise,4 (%) <.5 Output Power Stability,5 <±.5 Spatial Mode TEM Beam Diamater,6 (mm).2 ±.2 Beam Ellipticity,7.9 to. Astigmatism (%) < Repetition-Rate (MHz) 8 Polarization Horizontal >5: Pointing (µrad/nm) <8/ total Operating Voltage (VAC) 9 to 25 (auto ranging) Maximum Operating Current (A) <5 at 9 VAC (power supply) <7 at 9 VAC (chiller) <2 at 9 VAC (MRU x) System Power Consumption (W) 23 max., 3 typical Line Frequency (Hz) 47 to 63 Operating Temperature Range 5 to 35 C (59 to 95 F) Weight of Head 52 kg (5 lbs.) Weight of Power Supply 33 kg (73 lbs.) Umbilical Length 3m ( ft.) Chiller: Dimensions (L x W x H) 27 x 2 x 38 cm ( x 8 x 5 in.) Weight kg (25 lbs.) MRU Air Recirculator: Dimensions (L x W x H) 46 x 43 x 8.5 cm (8 x 7 x 3 in.) Weight 9 kg (2 lbs.) Specified at peak of tuning range. 2 Average speed measured over entire tuning range. 3 Based on sech 2 deconvolution of.65 times autocorrelation width. 4 Measured rms in a Hz to 2 MHz bandwidth. 5 Power drift in any two-hour period with less than ± C temperature change after a one-hour warm-up. 6 /e 2 at exit port. 7 Ratio of major to minor /e 2 beam diameter at exit port. of s Toll Free: (8) Tel: (48) Superior Reliability & Performance 27

30 Chameleon Compact OPO and OPO-Vis Synchronously-ed Optical Parametric of s Chameleon Compact OPO is a fully automated Optical Parametric tunable between nm and 6 nm. Chameleon Compact OPO-Vis, in addition to all the benefits of the Compact OPO, includes also Second Harmonic Generation (SHG) outputs of the Chameleon and the OPO signal wavelengths to provide additional seamless tuning between 34 and 8 nm. Designed specifically to be pumped by the Chameleon Ultra and Vision families of ultrafast lasers, the Chameleon Compact OPO family offers unique benefits. The non-linear medium is a fan-poled crystal that allows simple and broad tunability of the OPO output over a wide range of pump wavelengths. This feature enables truly independent tuning of Chameleon and Compact OPO output wavelengths over hundreds of nanometers. Thanks to the low OPO threshold and high efficiency, 2% of the Chameleon pump beam can be split off and sent directly to the output port to provide simultaneous user access to both the Chameleon and the OPO output beams. This feature enables two-color 28 Superior Reliability & Performance tech.sales@coherent.com

31 Chameleon Compact OPO and OPO-Vis Synchronously-ed Optical Parametric Key Advantages Wavelength extension to IR (OPO) and UV/Visible (OPO-Vis) Sealed hands-free performance Designed to be pumped by Chameleon Ultra and Vision families Automated wavelength tuning with single optic set Fan-poled OPO crystal for flexible pump wavelength Independent pump laser (Chameleon) and OPO/OPO SHG tuning Enables full multimodal imaging (MPE, SHG, THG and CARS) RS-232 and USB interface Filtered and dry air recirculation unit to tune across water absorption bands Vis and Idler outputs available also as after-sale upgrades of non-linear microscopy studies with a flexibility that, until now, required at least two independent lasers. The OPO-Vis extends further this flexibility by adding tunability in the UV, visible and near IR wavelengths. Both Chameleon and the Compact OPO families are fully computer-controlled and automatically tuned. Their combined output offers an overall tuning range in excess of 9 nm, from 68 nm to 6 nm, accessible within seconds. This broad and independently accessible tuning range is useful for two-color MPE microscopy, SHG and THG microscopy, and CARS microscopy of lipids. Wavelengths above. micron optimally excite the new mfruit family of fluorescent proteins at their excitation peaks, in wavelength regions of minimum damage and deepest tissue penetration. The combination of the low pump threshold and the industry-record high power of Chameleon guarantee plenty of power at both the Chameleon and OPO outputs to compensate for losses in complex microscope systems and to enable deep multimodal imaging. The industry s smallest footprint of Chameleon Compact OPO makes it simple to add this laser to existing multiphoton set-ups and upgrade MPE facilities to fully multimodal operations ready for the most advanced spectral imaging and manipulation techniques. Extension into UV and visible wavelengths enables the Chameleon Compact OPO-Vis to address applications beyond multiphoton microscopy, such as spectroscopy and non-linear optics. The optional idler output enables a unique automated tuning range between 34 nm and 6 nm and 75 nm to 4 nm, enabling also time-resolved vibrational spectroscopy. Multi-user facilities will greatly benefit from this unprecedented flexibility while individual investigators will appreciate how the many possible upgrades can follow their changing research objectives, even with limited initial budgets. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 29

32 Chameleon Compact OPO and OPO-Vis Synchronously-ed Optical Parametric of Specifications ed by ed by Chameleon Compact OPO Chameleon Ultra II Chameleon Vision II Tuning Range (nm) to 6 to 35 Wavelength Range (nm) 74 to to 88 Output Power, Signal 2 (mw) >7 >7 3 Output Power Available 4 (%) when pumping OPO ~5 in bypass mode ~95 Pulsewidth (fs)(typical) 2 M 2 (typical). Beam Diameter (mm) 2 Beam Divergence (mrad)(typical).5 Polarization Repetition-Rate (MHz) Dimensions (L x W x H) Horizontal 8, locked to pump laser 52 x 36.9 x 5.8 cm (2.5 x 4.5 x 6.2 in.) Additional Tuning Range,5 (nm) 75 to 4 Idler Output Power 6 (mw) > Additional Signal Output Power 7 (%) 5 Tuning range depends on Wavelength. 2 At maximum of pump and OPO signal tuning curve. 3 Vision Dispersion settings optimized for OPO. 4 Typical. Please refer to Chameleon datasheet for respective power specifications. output not available with Max IR option. 5 In addition to OPO signal output range. All other specifications are unaffected. 6 At maximum of pump and OPO idler tuning range. 7 No access to pump beam. s Compact OPO Signal Wavelength (nm) Chameleon Ultra II and Compact OPO Tuning Range uning R Chameleon Wavelength (nm) 3 Superior Reliability & Performance tech.sales@coherent.com

33 Chameleon Compact OPO and OPO-Vis Synchronously-ed Optical Parametric Specifications Idler Option Wavelength Combination OPO Bypass Mode Chameleon Ultra II Chameleon SHG Tuning Range (nm) 68 to 8 34 to 54 Output Power 2 (mw) >35 > Pulse Width (fs)(typical) 4 4 M 2 (typical) <. <. OPO Operation Chameleon Ultra II OPO Chameleon SHG OPO SHG Tuning Range (nm) 74 to 88 to 6 37 to 44 5 to 8 5 Output Power 3 (mw) >5 >7 > > Pulse Width 2 (fs)(typical) Polarization Horizontal Repetition-Rate (MHz) 8 Dimensions (L x W x H) 52 x 36.9 x 5.8 cm (2.5 x 4.5 x 6.2 in.) Tuning Range (nm) 75 to 4 5 Idler Output Power 4 (mw) > All specifications are shown for pumping with Chameleon model Ultra II. Other pump options available. 2 At peak of tuning curve. 3 At peak of pump laser wavelength and OPO wavelengths. 4 At maximum of pump and OPO idler tuning range. 5 wavelength dependent. Output Port Chameleon Fundamental - High Power (68 nm to 8 nm) Output Scheme I II III IV V VI Chameleon Fundamental - Low Power (74 nm to 88 nm) Chameleon Fundamental - Depleted Chameleon SHG - High Power (34 nm to 54 nm) Chameleon SHG - Low Power OPO Signal ( nm to 6 nm) OPO Signal - Depleted OPO Signal SHG (5 nm to 8 nm) OPO Idler of s OPO (fundamantal or SHG)/nm Chameleon Compact OPO-Vis Tuning Range Possible wavelength combinations are in shaded area Chameleon + OPO Chameleon + OPO SHG Chameleon SHG + OPO Chameleon SHG + OPO SHG Chameleon (fundamantal or SHG)/nm Toll Free: (8) Tel: (48) Superior Reliability & Performance 3

34 Mira-OPO Synchronously-ed Optical Parametric of s The Mira-OPO is a family of synchronously-pumped optical parametric oscillators that extend the wavelength range of the Mira-9, Mira-HP and Vitara-T HP ultrafast oscillators. The Mira-OPO is available in four different OPO crystal formats; Periodically Poled KTP, Fan-Poled KTP, Bulk KTP and Bulk CTA. The choice of bulk or periodically-poled crystal technology lets users select the best solution based on tuning, ease of use and performance for their specific application. For maximum flexibility, any version of the Mira-OPO can be upgraded to any other version. PP-Automatic Version: Periodically-Poled OPO Crystal This version of the Mira-OPO allows the output wavelength to be tuned without changing the pump wavelength. By taking advantage of the periodicallypoled, quasi-phase-matched OPO crystal, a simple electronic adjustment of the OPO s cavity length tunes the output wavelength. The PP crystal is designed for pumping at a wavelength close to the peak of the Ti:Sapphire gain spectrum, where the Mira output power is highest. This near fixed pump wavelength translates directly into a relatively flat power-tuning curve as a function of wavelength. Wavelength tuning and stabilization are achieved with a feedback loop based on a miniature spectrometer within the Mira-OPO head enclosure. Relative power and humidity sensors are included with each unit and full electronic control of the output wavelength is accomplished via either the accompanying electronics unit or a computer with an RS-232 interface (LabVIEW program and RS-232 commands are supplied). FAN-PP-Automatic Version: Fan-Poled KTP OPO Crystal Further extending the capabilities of our PP-Automatic OPO is a new, and truly unique, Fan-crystal option. Rather than having a single fixed poling period in the OPO gain crystal matched to one pump wavelength, the crystal is poled in a fan geometry across the width of the crystal providing a continuously variable quasiphase-matching period. This allows fully independent tunability between pump and OPO output wavelengths enabling two-color applications such as simultaneous MPE of different dyes, uncaging, CARS/SRS and other two-color pump-probe experiments. Bulk KTP and CTA Crystal Versions Using non-critically phase-matched crystals, the bulk crystal version of the Mira-OPO offers high conversion efficiency and broad tuning ranges. The OPO cavity length automatically stabilizes to maintain stability at the chosen operation point. An optional advanced control scheme offers additional stabilization with respect to pulse width, bandwidth or power. 32 Superior Reliability & Performance tech.sales@coherent.com

35 Mira-OPO Synchronously-ed Optical Parametric Key Advantages Unique Fan-Poled crystal technology for independent tunability of pump and OPO wavelengths IR and visible/ir versions Simple, fast wavelength tuning Low pump threshold: As low as.5w High power visible output using highly efficient intracavity doubling Access to idler wavelengths to ~4 μm using optional optics sets Active cavity length stabilization on all models Active pulse width or bandwidth stabilization (optional for Bulk Crystal version) Options available include: - Femtosecond and picosecond crystal options - Short pulse configurations (sub- fs and sub-5 fs) - Difference Frequency Generator (DFG) option extends wavelength coverage to 5 µm and beyond of Choice of Linear or Ring-Cavity Designs PP-Automatic, Fan-Poled and Bulk Crystal configurations are available in a linear or ring-cavity design. The linear-cavity design is the best solution for maximum power at IR Signal and Idler wavelengths. The ring cavity Mira-OPO is the preferred choice for applications requiring high power in the visible range. The ring-cavity design with intracavity second harmonic generation (SHG) takes advantage of the high intracavity power to efficiently generate visible output from 5 nm to 7 nm, which fills the gap between the fundamental output and the SHG output of a modelocked Ti:Sapphire oscillator. All versions of the ring-cavity configuration also include optics that cover infrared operation. Overall, Mira-OPOs provide the industry s most unique range of wavelength coverage in the infrared through visible spectrum. The Mira-OPO is available in femtosecond, picosecond or long-picosecond configurations. s OPO Signal Wavelength (nm) Mira Fan Poled OPO Tuning Range (Linear IR Cavity Configuration) Any combination of pump wavelength and OPO Signal wavelength, indicated by the shaded area, is possible T Wavelength from Mira 9 or Mira HP (nm) OPO (mw) Mira OPO Fan-Poled Power Tuning Curves OPO (nm) 3 8 (nm) Toll Free: (8) Tel: (48) Superior Reliability & Performance 33

36 Mira-OPO Synchronously-ed Optical Parametric of Typical Tuning Curves for Femtosecond Mira-OPO PP-Automatic Average Power (mw) PP VIS 8 wavelength extension crystal (PP775) standard crystal (PP83) Wavelength (nm) Average Power (mw) PP IR 2 wavelength extension crystal (PP775) standard crystal (PP83) Wavelength (nm) High Power (G8/Mira HP) standard 83 crystal High Power (G8/Mira HP) 775 crystal option Mid Power (G/Mira 9) standard 83 crystal Mid Power (G/Mira 9) 775 crystal option Low Power (G5/Mira 9) standard 83 crystal Low Power (G5/Mira 9) 775 crystal option s 34 Specifications Periodically-Poled (PP-Automatic) Mira-OPO Model VIS S,2 VIS S2,3 VIS-FAN- IR S 2 IR S2 3 IR-FAN Cavity Configuration Ring cavity Ring cavity Ring cavity Linear Linear Linear with intra- with intra- with intra- cavity cavity cavity cavity SHG cavity SHG cavity SHG Tuning Range (nm) Signal SHG 4,5 55 to to to Signal 4,5 to 6 to 6 to 6 to 6 to 6 to 6 Idler (option) 75 to to to 4 75 to to to 4 Nominal or 83 Flexible or 83 Flexible Wavelength (nm) 74 to to 88 6 Average Power (mw) Verdi G8 pumped >5 >5 5 for fs >55 >65 65 for fs 4 for ps 52 for ps Mira-HP-F at 6 nm at 6 nm at 6 nm 7 at 3 nm at nm at nm 7 Verdi G pumped >5 >5 >5 >8 >25 >25 Mira-9F at 6 nm at 6 nm at 6 nm 7 at 3 nm at nm at nm 7 Verdi G5 pumped >4 >4 >4 >6 >6 >75 Mira-9F at 6 nm at 6 nm at 6 nm 7 at 3 nm at 3 nm at nm 7 Pulse Width 8 fs version (typical) 2 fs for 3 fs pump pulse ps version (typical).6 ps for.4 ps pump pulse Time-Bandwidth Product (all versions)(typical).6 Repetition-Rate (nominal)(mhz) 76 (other rep. rates up to 9 MHz available on request) Threshold (mw) High power version 9 <7 Low power version <5 Noise,2 (%) <.5 Spatial Mode TEM Typical Beam Diameter (/e 2 )(mm) 2.2 Typical Beam Divergence (full-angle)(mrad). Polarization Horizontal for IR Signal and Idler (>:) Vertical for VIS (>:) VIS version can be simply modified to produce IR performance. The necessary optics are included as standard with VIS versions. 2 S version uses one PP crystal with a pump wavelength of approximately 83 nm. 3 S2 version uses two interchangable PP crystals with pump wavelengths of approximately 83 nm and 775 nm. 4 Second output coupler (optional) allows access up to 8 nm. 5 In picosecond configuration the pump wavelength must be adjusted slightly in order to access the entire quoted tuning range. 6 Femtosecond version requires only one Fan-Poled PP crystal to cover this range of pump wavelengths. The picoscecond version requires two Fan-Poled PP crystals to cover this range of pump wavelengths. 7 Power specified optimized pump wavelength. 8 Assumes Gaussian pulse shape (deconvolution factor.7). 9 Mira OPO pumped by Verdi G pumped Mira 9 or Verdi G8 pumped Mira HP. Mira OPO pumped by Verdi G5 pumped Mira 9. RMS noise measured in Hz to MHz bandwidth. 2 With Verdi, noise is <.5% rms. With argon-ion pump, noise is <2% rms. Superior Reliability & Performance tech.sales@coherent.com

37 Mira-OPO Synchronously-ed Optical Parametric Typical Tuning Curves for Femtosecond Mira-OPO Bulk Crystal Average Power (mw) Bulk KTP VIS & IR Average Power (mw) Bulk CTA IR Wavelength (nm) Wavelength (nm) of VIS High Power (G8/Mira HP) IR High Power (G8/Mira HP) VIS Mid Power (G/Mira 9) IR Mid Power (G/Mira 9) VIS Low Power (G5/Mira 9) IR Low Power (G5/Mira 9) High Power (G8/Mira HP) eo beam High Power (G8/Mira HP) Idler option Mid Power (G/Mira 9) eo beam Mid Power (G/Mira 9) Idler option Low Power (G5/Mira 9) eo beam Low Power (G5/Mira 9) Idler option Specifications Bulk Crystal Mira-OPO KTP CTA Model VIS- IR- IR-3 Cavity Configuration Ring cavity with Linear cavity Linear cavity intracavity SHG Tuning Range 2 (high power)(nm) Signal SHG 525 to Signal 5 to 32 5 to to 6 (4 to 7 option available) Idler (option) 22 to 3 22 to 3 6 to 9 (7 to 2 option available) 7 Tuning Range 3 (low power)(nm) Signal SHG 53 to Signal 6 to 2 6 to 2 35 to 6 (4 to 7 option available) Idler (option) 23 to to to 83 (7 to 83 option available) 7 Average Power (mw) Verdi G8 pumped Mira-HP-F >75 at 57 nm >75 at 4 nm >75 at 57 nm Verdi G pumped Mira-9F >2 at 57 nm >24 at 4 nm >2 at 57 nm Verdi G5 pumped Mira-9F >6 at 57 nm >8 at 4 nm >6 at 57 nm Pulse Width 4 fs version (typical) 2 fs for 3 fs pump pulse 2 fs for 3 fs pump pulse ps version (typical).6 ps for.4 ps pump pulse.6 ps for.4 ps pump pulse Time-Bandwidth Product (all versions)(typical).6 Repetition-Rate (nominal)(mhz) 76 (other rep. rates up to 9 MHz available on request) Threshold (mw) <5 Noise 5,6 (%) <.5 Spatial Mode TEM Typical Beam Diameter (/e 2 )(mm).25 Typical Beam Divergence (full-angle)(mrad).3 Polarization Horizontal for IR Signal (>:) Vertical for Idler (>:) Vertical for VIS (>:) VIS version can be simply modified to produce IR performance. The necessary optics are included as standard with VIS versions. 2 Mira OPO pumped by Verdi G pumped Mira 9 or Verdi G8 pumped Mira-HP. 3 Mira OPO pumped by Verdi G5 pumped Mira 9. 4 Assumes Gaussian pulse shape (deconvolution factor.7). 5 RMS noise measured in Hz to MHz bandwidth. 6 With Verdi, noise is <.5% rms. With argon-ion pump, noise is <2% rms. 7 Not available simultaneously with Signal. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 35

38 Harmonic Generation for Ultrafast Second, Third and Fourth-Harmonic for Ti:Sapphire of s The Harmonic Generator is an extremely flexible and adaptable wavelength extension accessory for Coherent s entire range of ultrafast oscillators (Mira, Chameleon, Vitara, Mira OPO and Chameleon Compact OPO). A wide range of non-linear crystals and configuration options are available that span second, third and fourth harmonic generation of picosecond or femtosecond pulses at input powers up to 5W. For third harmonic generation, the unique high efficiency collinear mixing design with walk-off compensation and in-line time delay is simple to align without the complexity of separate optical delay lines and fundamental and SHG spatial separation and recombination. Key Advantages Magnetically indexed crystals simplifies SHG/THG/FHG conversion Walk-off compensator maintains good beam circularity Delay compensator for simple in-line THG generation Easily upgradable Autotracker option for SHG and THG. Provides automatic phase matching optimization as input wavelength is changed. 36 Specifications 8 nm Input Wavelength High Power Standard THG FHG- FHG-2 (mixing SHG SHG (incl. Standard (SHG of SHG) fundamental & (SHG only) SHG) (incl. Standard THG)(incl. SHG, SHG) THG, & FHG-) Conversion Efficiency/Power for input wavelength of 8 nm Mira HP-F, 8W pump 4%/.4W 25%/875 mw 9%/35 mw Call Factory Call Factory Mira HP-P, 8W pump 6%/48 mw 5%/45 mw 6%/8 mw Call Factory Call Factory Mira 9-F, W pump 4%/56 mw 2%/28 mw %/4 mw 4%/45 mw 2.%/.6 mw Mira 9-P, W pump 5%/2 mw %/4 mw 4%/56 mw Call Factory Call Factory Mira 9-F, 5W pump Call Factory 4%/3 mw 2%/3 mw Call Factory Call Factory Mira 9-P, 5W pump Call Factory 2%/5 mw.8%/5 mw Call Factory Call Factory Input Wavelength Range (nm) 68 to 8 68 to 8 68 to 8 84 to to 84 Output Wavelength Range (nm) 34 to to to 36 2 to 23 9 to 2 Dimensions (L x W x H) 385 x 286 x 22 mm 58 x 4 x 22 mm (5.2 x.3 x 8.7 in.) (22.9 x 6.2 x 8.7 in.) Requires optics change. 2 Specified at 88 nm input wavelength. Superior Reliability & Performance tech.sales@coherent.com

39 Pulse Picker for Selecting Pulses from Modelocked Ti:Sapphire of The Pulse Picker, a standalone accessory for selecting pulses from femtosecond or picosecond Ti:Sapphire oscillator, features a rugged optomechanical head assembly and a versatile controller. The acousto-optic Bragg cell in the head provides simple single-pass diffraction of the pulse train, while the controller lets the user select any repetition-rate by dividing the Ti:Sapphire oscillator frequency by any integer from 6 to 892. By applying external control signals, rates down to even single-shot are possible. Two Bragg cell options are available, SiO 2 for applications demanding the highest contrast ratio for input powers >2W, or the TeO 2 cell which is recommended for input powers <2W and for higher diffraction efficiency. Key Advantages For use with femtosecond or picosecond lasers Wavelength options covering 5 to 3 nm Single-pass Bragg cell for easy alignment High diffraction efficiency and contrast ratio Dedicated controller with CPU LCD display of operational parameters Controller settings provide widely variable repetition-rate: 9.3 khz to 4.75 MHz s Specifications Pulse Picker Pulse Repetition-Rate 9.5 khz to 4.75 MHz variable by integer division of oscillator frequency. The unit also can be externally triggered at any repetition-rate below 4 MHz or operated single-shot. Diffraction Efficiency 2 (%) TeO 2 Cell >6 SiO 2 Cell >5 Contrast Ratio 3 TeO 2 Cell >5: SiO 2 Cell >: Wavelength Range (nm) <68 to >8 4,5 (other ranges available on request) The Pulse Picker accepts the nominal 76 MHz input frequency from the synchronous output photodiode of the Mira 9. A 38 MHz RF clock is divided by 8 thru Percentage of incident pulse energy in diffracted output pulse. 3 Main pulse to non-adjacent pulses. Main pulse to adjacent pulse is >: TeO2 cell or >2: SiO2 cell. Contrast ratios for high power pumped femtosecond systems are.5 times the given values for the TeO2 cell. 4 For SHG operation, the fundamental output must be pulse picked first, then frequency doubled. 5 Requires optics changes. Toll Free: (8) Tel: (48) Superior Reliability & Performance 37

40 Pulse Switch for Mira-9 Cavity Dumper of s The Pulse Switch for Mira-9 ultrafast oscillators is a compact, bolt-on accessory enabling cavity-dumped operation to produce higher pulse energy at lower repetition-rates. Using intracavity acousto-optic modulation to switch pulses out of the Mira cavity provides a convenient way to both increase the output pulse energy and reduce the laser repetition-rate without using an amplifier system. Providing repetition-rates from 9 MHz down to single-shot, this configuration delivers up to 6 nj of pulse energy. The Pulse Switch accessory, compatible with both the femtosecond and picosecond cavities of the Mira-9-F, Mira-9-P and 9-D, extends the Mira-9 s cavity length to include the Pulse Switch s acousto-optic modulator. An optional integrated frequency-doubling module that provides conversion efficiencies up to 4% further extends the capabilities of the Pulse Switch. Mira-9, with the addition of the Pulse Switch or its optional frequency-doubler, is ideal for processes and experiments that benefit from lower duty cycle and/or higher pump intensity, such as time-correlated singlephoton counting, non-linear optics, transient absorption spectroscopy, and pump-probe spectroscopy. 38 Superior Reliability & Performance tech.sales@coherent.com

41 Pulse Switch for Mira-9 Cavity Dumper Key Advantages Provides cavity-dumped operation with all Mira-9-F/P/D oscillators Simple to install and remove as needed Optional integrated SHG provides conversion efficiencies up to 4% Can be purged for tuning above 92 nm RF overload safety circuit External pump configuration (optional) Control box (supplied) includes: - Internal frequency divider (:6 to :26,) - External trigger input (TTL) - Digital and analog phase adjustment of RF pulse (36 ) - Electronic delay - Synchronization and RF pulse monitor outputs of Specifications Mira-9 with Pulse Switch Cavity Dumper Femtosecond Configuration Picosecond Configuration Pulse Energy,2,3 >75 nj up to 5 khz >45 nj up to khz >65 nj at khz >4 nj at 5 khz >3 nj at 5 khz Pulse Duration FWHM,4 <5 fs (2 fs typical) <2 ps Tuning Range 7 to 99 nm (Verdi 8W or W) 7 to 9 nm (Verdi 5W or 6W) Contrast Ratio >5: (for non-adjacent pulses) Repetition-Rate 9 MHz to 2 Hz (internal trigger) for femtosecond configuration 4 MHz to 2 Hz (internal trigger) for picosecond configuration down to single-shot (external trigger) Polarization Horizontal At 8 nm. 2 Power change in any two-hour period after a one-hour warm-up is typically <9% depending on mounting surface. 3 Mira-9 pumped by Verdi G5 or Verdi G. 4 Real pulse width assuming sech 2 deconvolution factor of autocorrelation. s Pulse Energy (nj) Typical Cavity Dumper Performance (Mira-9-D at 8 nm, 4.5W Verdi pump power) fs ps.,, Pulse Repetition Rate (khz) Toll Free: (8) Tel: (48) Superior Reliability & Performance 39

42 Pulse Compressors Pulse Compression for Coherent Ti:Sapphire of Pulse compressors are versatile accessories that temporally compress the broadband pulses from Mira, Vitara, Chameleon and Vitesse oscillators enabling operation very close to the transform limit. By adding Group Velocity Dispersion (GVD), pulse compressors also allow users to pre-compensate for the dispersion introduced when downstream optics are added in order to shorten the pulse width at the sample. Two types of Coherent pulse compressor accessories are available: the Compact Pulse Compressor (CPC-II), based on chirped-mirror technology, and the prismbased SPO-I and SPO-II Compressors. s Specifications CPC-II SPO-I SPO-II Mira < fs <7 fs <7 fs Vitara <2 fs for >25 nm bandwidth N/A <2 fs for >25 nm bandwidth <5 fs for nm bandwidth <25 fs for 5 nm bandwidth <4 fs for 3 nm bandwidth Vitesse Contact tech.sales@coherent.com for recommendations regarding your setup Chameleon For MPE applications, please refer to the Chameleon product family that offers a dedicated pre-compensation unit for microscope setups, or contact tech.sales@coherent.com for CPC-II or SPO combinations. Typical Compressed Pulse Width from Vitara-T with CPC-II Pulse Intensity Bandwidth FWHM (nm) 4 Superior Reliability & Performance tech.sales@coherent.com

43 Pulse Compressors Compact Pulse Compressor (CPC-II) Featuring both coarse and fine adjustments, the Compact Pulse Compressor (CPC) provides highly accurate control of the oscillator s final pulse width. Using chirped-mirror technology, the CPC-II provides an ultra-compact footprint for maximum ease-of-use. The input and output beam ports are in line to enable simple experimental setups. Typical Measured Pulse from Vitara-T After Compression with CPC-II Pulse Measured Using FC Spider of Pulse Intensity Time (fs) SPO-I and SPO-II s The SPO-I and SPO-II are prism-based pulse compressor setups specifically designed with a larger footprint than the Compact Pulse Compressor. The SPO-I compresses the pulses of the Mira-9 and Mira-HP oscillators. It consists of an external prism assembly head, a birefringent filter (BRF), and a mirror-based starter galvanometer all added to the Mira-9 or Mira-HP laser head. The SPO-II is a pulse compressor for Mira or Vitara that consists of two, separated prism assembly heads. Autocorrelation of Compressed Pulse (a.u.) Typical Autocorrelation of ~ nm Bandwidth Pulses from Mira 9-F with SPO-I option Delay (fs) Toll Free: (8) Tel: (48) Superior Reliability & Performance Autocorrelation FWHM = 8 fs Deconvolved Pulse FWHM = 7 fs

44 Synchrolock-AP Synchronization for Mira and Vitara Ti:Sapphire of s The Synchrolock-AP is used to accurately synchronize two Mira or Vitara-T lasers together, or to synchronize a Mira or Vitara-T laser to an external RF source. Operating in the femtosecond or picosecond (Mira only) regime, the Synchrolock-AP allows smooth wavelength tuning while keeping the lasers synchronized. Three separate actuators operate at different locations inside the laser head to compensate low, medium and high frequencies. The actuators are controlled by feedback electronics while a high-speed photodiode simultaneously monitors the laser repetition-rate. The Synchrolock-AP uses the 9th harmonic content of the photodiode signal to provide a higher signalto-noise ratio, which leads to tighter jitter lock. In this way Synchrolock-AP provides extremely low jitter while ensuring long-term stability. GUI for Synchrolock-AP 42 Superior Reliability & Performance tech.sales@coherent.com

45 Synchrolock-AP Synchronization for Mira and Vitara Ti:Sapphire Key Advantages The Synchrolock-AP accessory locks the pulse repetition-rate of one Slave Mira or Vitara-T laser to another Master Mira or Vitara-T laser, or to a Master external RF source Femtosecond (Mira and Vitara-T) and/or picosecond (Mira only) operation Three cavity length actuators provide jitter stabilization over a broad bandwidth and large dynamic range User adjustable delay between locked pulse trains of up to 3 ns with around 22 fs resolution (for a 76 MHz cavity) Simple fiberoptic coupling of slave output beam to the Synchrolock-AP detection system results in minimal losses and ease of use Unique feedback locking mechanism locks to the 9th harmonic of the input signal for enhanced signal to noise performance and tighter synchronization between slave and master oscillators User-friendly GUI enables automatic locking acquisition, delay control and system monitoring of Specifications,2,3,4 5 Slave Jitter Mira (fs) Mira (ps) Vitara-T Master Mira (fs) Mira (ps) Vitara-T RF Source 6,7 (low harmonic content) RF Source 7,8 (high harmonic content) Jitter specification is rms (.2 to 6 Hz) over minute acquisition time assuming Gaussian statistics. Jitter values are in femtoseconds. 2 Jitter values are measured using the time-averaged cross-correlation between slave and master optical outputs with the Synchrolock-AP operating in harmonic lock. 3 Specifications are based on use of isolation optical table, solid-state chillers and Verdi oscillator pumping. 4 Specifications apply to an oscillator (laser or external) synchronization signal between 7 MHz and 9 MHz. 5 Mira specifications apply to X-Wave tuning range (7 nm to 98 nm). Specifications cover mixed wavelength systems in the X-Wave range. 6 Electronic external sync signal (low harmonic content) into optional slow trigger/oscillator board. 7 Fundamental external electronic sync signal input requirements: to + dbm amplitude into 5Ω, <- dbc/hz phase noise at khz from carrier. 8 Electronic external sync signal (9th harmonic content >-2 dbm) into COMB IN input of the controller. s Relative Jitter (ps) Example showing relative jitter between pulse trains from two synchronized Mira-9 lasers t jitter = 55 fs (RMS;.2 Hz to khz) Time (sec) Toll Free: (8) Tel: (48) Superior Reliability & Performance 43

46 CEP Stabilizer for Vitara Carrier to Envelope Phase (CEP) Stabilizer for Vitara of s The Vitara CEP Stabilizer is a state-of-the art Carrier-to- Envelope Phase stabilizer accessory designed exclusively for Vitara-T. Through the use of active feedback control, Vitara CEP locks the carrier envelope offset frequency (w o ) to a fraction of the repetition-rate w r. This establishes a fixed phase relation between the carrier and the envelope. Maintenance of this phase relationship is of paramount importance in experiments such as Above- Threshold Ionization (ATI) or generation of isolated attosecond pulses. Carrier Offset Phase Vitara CEP consists of CEP actuators incorporated in the Vitara-T, a quasi-collinear f-to-2f interferometer and a wide bandwidth electronics feedback loop. The interferometer uses a photonic crystal fiber to generate an octave-scanning optical spectrum. The red end of this spectrum is frequency-doubled and combined with the green end of this same broad spectrum. A fast photodetector senses the resultant beat frequency and at w o, the carrier envelope offset frequency. Our feeback electronics control the fast and slow actuators inside the Vitara-T to stabilize w o to a fraction of the repetition-rate which is detected by a fast photodiode in the Vitara-T. CEP Self-Referencing Stabilization Scheme SHG beat note 44 Superior Reliability & Performance tech.sales@coherent.com

47 CEP Stabilizer for Vitara Carrier to Envelope Phase (CEP) Stabilizer for Vitara Key Advantages Low phase noise due to excellent common mode noise supersession in the quasi-collinear interferometer design Monolithic construction for long term stability Requires <2 mw from Vitara-T Dual actuators to provide both large bandwidth and dynamic range Typical locking times in excess of hours of Specifications CEP Stabilizer for Vitara Optical Power Requirements 2 mw average power from Vitara (beamsplitter included with system) Input Pulse Repetition-Rate (MHz) 7 to 9 Beat Note S/N Ratio (db in khz resolution bandwidth) >3 Offset Frequency /4 of the repetition frequency s Beat Note Signal To Noise Ratio (db) Vitara-T with CEP Stabilizer Typical Data Showing Long Term Stability of Detector Beat Note Time (hours) Toll Free: (8) Tel: (48) Superior Reliability & Performance 45

48 Legend Elite High-Performance, khz Repetition-Rate, Ti:Sapphire s of s Legend Elite series amplifiers have become the top selling khz, repetition-rate Ti:Sapphire regenerative amplifiers on the market due to their leading combination of performance, stability and reliability. They feature an integrated Evolution pump laser, a thermally stabilized regenerative amplifier and a stretcher/compressor in a single, compact enclosure. The E-2 Engine, our regenerative amplifier module which is common to every Legend Elite amplifier, now includes our proprietary slab rod design to reliably provide high energy pulses with high efficiency while delivering a guaranteed beam quality unsurpassed by alternative designs. In the last few years, Coherent has developed some breakthrough passive and active technologies to become a leader in both very high power (up to 5W) and Carrier to Envelope Phase (CEP) stabilized ultrafast amplifiers for the most demanding advanced applications such as attosecond science. The new Legend Elite HE+ and Legend Elite Duo HE+ integrate these new technologies, including all CEP-grade hardware, to ensure unmatched level of intrinsic stability with best-in-class energy and pointing performance (respectively specified at <.5% rms and < µrad rms) so every ultrafast application can benefit from these cutting edge developments. Furthermore both the Legend Elite HE+ and Duo HE+ are de facto CEP-ready, offering to the users the maximum forward flexibility through up-gradability. Legend Elite HE+: Highest power available from a regenerative amplifier. The Legend Elite HE+ now offers the highest output power (up to >6W) available from a regen-only ultrafast amplifier using thermo-electrical cooling of the rod. For lower power versions (up to 4W), the efficiency of our proprietary slab rod design allows for a simple and robust water cooled scheme. Powered by an integrated Evolution pump laser, the legend Elite HE+ is very compact and when seeded by an integrated Vitara ultrafast oscillator the small foot print of such 2-box high-performance amplifier system allows sophisticated experimental setups on a single optical table. Legend Elite Duo HE+: highest khz output power available with simple thermo-electrical cooling technology. For all the energy/power hungry applications, Coherent is now offering the Legend Elite Duo HE+ with up to >2 mj of output energy per pulse at khz or up to >5W of output power at 5 khz. Compared to the Legend Elite HE+, the Duo HE+ integrates an additional single pass booster amplifier (additional 46 Superior Reliability & Performance tech.sales@coherent.com

49 Legend Elite High-Performance, khz Repetition-Rate, Ti:Sapphire s Key Advantages E-2 Engine, thermally stabilized regenerative amplifier platform for unsurpassed performance, reliability, and environmental stability Advanced slab rod design with simple water (up to 4W) or enhanced TE (up to 5W) cooling Proprietary conditioning optics for optimized output beam quality CEP-grade components for intrinsic exceptional stability BandMax technology in the USX series delivers reliable, sub-25 fs pulse Repetition-rate options available up to khz Integrated Evolution pump laser for compactness and stability Additional external pump laser for high power configurations Ready for seeding with Vitara, Vitesse or Mira oscillators for maximum flexibility and proven stability Multiple upgrade paths assure initial investment meets your future needs of external pump laser required for some models) to more than double the output of its regenerative stage while maintaining the same output stability and preserving an excellent mode quality. Pulse Width Configurations: All Legend Elite HE+ and Duo HE+ are available in 4 different pulse width configurations: the F models have a pulse widths specified at <3 fs. The ultrabroadband input from the Vitara one-box oscillator, is the key to the performance of the USP (Ultra Short Pulse) versions which feature a proprietary, mixed grating, stretcher/compressor design for optimum pulse width stability. This design very comfortably supports the sub-35 fs specification for USP systems. For applications such as extreme ultra-violet or attosecond pulse generation, where the shortest pulses are essential, the Vitara T seeded Ultra Short Extreme (USX) versions provide sub-25 fs pulses. Our proprietary BandMax technology is the key to generating and sustaining the broad amplified bandwidth necessary to support reliable, sub-25 fs pulses. Picosecond models provide the short pulses and narrow bandwidth required for both timeresolved and spectrally-resolved experiments. Picosecond versions are typically seeded with a femtosecond oscillator that is spectrally-masked prior to amplification. CEP Stabilization: For applications requiring Carrier Envelope Phase stability, the sub-25 fs Legend Elite USX and sub-35 fs Legend Elite USP models are available with CEP stabilization, combining the benefits of regen design (unmatched mode quality, energy and pointing stability) with a world-class CEP performance (see page 7). With pulse widths from <25 fs to the picosecond regime, pulse energies up to >2 mj and output power up to >5W, there is always a Legend Elite model for your ultrafast amplifier application. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 47

50 Legend Elite HE+ High-Performance, khz Repetition-Rate, Ti:Sapphire s of s Specifications Legend Elite Center Wavelength 2 (nm)(nominal) 8 Repetition-Rate 3 (khz), 5 or Contrast Ratio HE+ >: pre-pulse >: post-pulse Power Stability,2 (%)(rms) <.5 Beam Pointing Stability,2 (μrad)(rms) < Spatial Mode TEM, M 2 <.3 Polarization linear, horizontal Pulse Width Configuration USX USP F P Pulse Width (fs)(fwhm) <25 4 <35 5 <3 6 5 to 5 6,7 Tunability 8,9 (nm) NA NA 77 to to 845 Configuration -I -II -III Evolution-5 Evolution-3 Evolution-45 Energy Per Pulse (mj) >. at khz >4. at khz >5. at khz >.3 at 5 khz >.8 at 5 khz >.2 at 5 khz >. at khz >.4 at khz >.6 at khz Specifications are given at center wavelength unless otherwise mentioned. Please contact factory for specifications at other wavelengths. 2 For other wavelengths, please contact factory. 3 Repetition-rate must be specified when ordered and will be optimized prior to shipment. Options for more than one repetition-rate available. Please contact factory for other repetition-rates. 4 When seeded by Vitara-T. For other seed lasers, please contact factory. An FFT of the pulse spectrum is used to calculate the transform-limited pulse width and a deconvolution factor which is then used to determine the real pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator). 5 When seeded by Vitara. For other seed lasers, please contact factory. A Gaussian pulse shape deconvolution factor (.7) is used to determine the pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator). 6 When seeded by Vitara, Mira or Vitesse. For other seed lasers, please contact factory. A Gaussian pulse shape deconvolution factor (.7) is used to determine the pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator). 7 For longer pulse width, please contact factory. 8 Optics change may be required. 9 When seeded with Mira. For other seed lasers, please contact factory. Contrast ratio is defined as the ratio between the peak intensity of the output pulse to the peak intensity of any other pulse that occurs greater than ns before or after the output pulse. Under stable environmental conditions. 2 Over 24 hours. Output Power (W) Legend Elite HE+ Long Term Power Stability Power (.% rms) Temperature Lab Temperature ( C) Legend Elite HE+ Power Stability (under extreme lab conditions) Time (hours) 48 Superior Reliability & Performance tech.sales@coherent.com

51 Legend Elite Duo HE+ High-Performance, khz Repetition-Rate, Ti:Sapphire s Specifications Legend Elite Duo HE+ Center Wavelength 2 (nm)(nominal) 8 Repetition-Rate 3 (khz), 5 or Contrast Ratio >: pre-pulse >: post-pulse Power Stability,2 (%)(rms) <.5 Beam Pointing Stability,2 (μrad)(rms) < Spatial Mode TEM, M 2 <.35 3 Polarization linear, horizontal Pulse Width Configuration USX USP F P Pulse Width (fs)(fwhm) <25 4,8 <35 5,9 <3 6 5 to 5 6,7,8 Configuration -I -II -III Evolution HE Evolution HE Evolution HE + Evolution Evolution 45 4 Energy Per Pulse (mj) >8. at khz >. at khz >2. at khz >2.5 at 5 khz >3. at 5 khz >. at khz >.2 at khz Specifications are given at center wavelength unless otherwise mentioned. Please contact factory for specifications at other wavelengths. 2 For other wavelengths, please contact factory. 3 Repetition-rate must be specified when ordered and will be optimized prior to shipment. Options for more than one repetition-rate available. Please contact factory for other repetition-rates. 4 When seeded by Vitara-T. For other seed lasers, please contact factory. An FFT of the pulse spectrum is used to calculate the transform-limited pulse width and a deconvolution factor which is then used to determine the real pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator). 5 When seeded by Vitara. For other seed lasers, please contact factory. A Gaussian pulse shape deconvolution factor (.7) is used to determine the pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator). 6 When seeded by Vitara, Mira or Vitesse. For other seed lasers, please contact factory. A Gaussian pulse shape deconvolution factor (.7) is used to determine the pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator). 7 For longer pulse width, please contact factory. 8 Not available in -III pump configuration. 9 <4 fs in -II and -III pump configurations. Contrast ratio is defined as the ratio between the peak intensity of the output pulse to the peak intensity of any other pulse that occurs greater than ns before or after the output pulse. Under stable environmental conditions. 2 Over 24 hours. 3 M 2 <.5 in -III pump configuration. 4 Mounted external to amplifier enclosure. of s Near-Field Beam Profile (Duo HE+ USP) Typical Pulse Width ~23 fs (Duo HE+ USX) Legend Elite Duo HE+ Long Term Power Stability Autocorrelation Intensity Output Power (W) Power (.35% rms) Time Time (hours) Toll Free: (8) Tel: (48) Superior Reliability & Performance 49

52 Legend Elite Cryo PA Cryogenically-Cooled, Ti:Sapphire Power of s The Legend Elite Cryo PA is a field-proven add-on power amplifier that can increase the pulse energy output of the Legend Elite amplifiers to more than 2 mj. Cryogenic cooling helps to produce high pump conversion efficiency and enhanced beam quality for high-power operation in various configurations with pulse widths to <3 fs and repetition-rates to khz. Our integrated Evolution pump laser ensures the system s stable and reliable operation. Operation of the Cryo PA is based on directly imaging the output from the Legend Elite amplifier to the cryogenic amplifier without using spatial filters or saturable absorbers. The Cryo PA combines the basic high power amplification capabilities of cryogenicallycooled Ti:Sapphire technology with Coherent s proprietary vacuum cryogenic chamber, which manages the thermal conditions of the Ti:Sapphire crystal. This design approach minimizes beam distortion during amplification. Using a single power amplifier stage results in a superior beam quality, simpler operation and a more compact footprint compared to traditional multi-stage configurations. The design of the pulse compressor, which is also integral to the amplifier, is based on our experience developing terawatt amplifiers with master gratings. This compressor design ensures high efficiency with minimal spatial distortion. The resultant compressed beam profile is highly symmetrical with typical M 2 values <.3. Typical Cryo PA Power Stability over > hrs., 7.5 mj, khz Typical TOPAS OPA Output Energy ed by Legend Elite Cryo PA at.5 mj Energy (µj) , 6, 2, Wavelength (nm) S + I NDFG NDFG Superior Reliability & Performance tech.sales@coherent.com

53 Legend Elite Cryo PA Cryogenically-Cooled, Ti:Sapphire Power Key Advantages Closed-loop, cryogenically-cooled Ti:Sapphire technology High pulse energy to >2 mj Pulse duration options to <3 fs Integrated Evolution pump laser for pulse-to-pulse stability better than.75% rms Multiple interlocks for vacuum, temperature and safety provide stable system operation and user protection Compact, high-efficiency, remotely-controlled optical compressor for ease of use Electronics ready for complete computer control of Specifications Legend Elite Cryo PA Center Wavelength (nm)(nominal 8 Repetition-Rate Options (khz), 5, or Pulse Duration 2 (fs)(fwhm) <3 (USX model), <4 (USP model) Energy-per-Pulse 3 (mj) Options to >2 Contrast Ratio 4 (ns) >: pre-pulse; >: post-pulse Contrast Ratio (ASE) > 6 : Power Stability 5 (rms)(8 hrs.) <.75 Energy Stability (6, pulses)(% rms) < Spatial Mode TEMoo, M 2 <.45 Polarization Horizontal 6 Evolution-3, Evolution-HE Repetition-rate must be specified when ordered and will be optimized prior to shipment. 2 When seeded by Coherent Vitara. A Gaussian pulse shape de-convolution factor (.7) is used to determine the pulse width from an autocorrelator signal measured by a Coherent SSA (Single-Shot Autocorrelator). For other seed lasers, please contact factory. 3 Pulse energy is dependent on pre-amplifier performance and number of pump lasers used (contact factory for details). 4 Contrast ratio is defined as the ratio between the peak intensity of the output pulse to the peak intensity of any other pulse that occurs greater than ns before or after the output pulse. Nanosecond contrast can be improved to >,,: pre with <5% energy loss with optional pulse slice. 5 Under stable environmental conditions. 6 Model and number of pump lasers used dependent on Cryo PA output energy (contact factory for details). s Toll Free: (8) Tel: (48) Superior Reliability & Performance 5

54 Libra One-Box, Ultra-Stable, khz Repetition-Rate, Ti:Sapphire System of s Libra is the industry-leading family of integrated, one-box, computer-controlled, khz- repetition-rate, Ti:Sapphire amplifiers. Configured in a ruggedized, ultra-stable, compact platform, it features high performance comparable to advanced multi-box systems. The compelling, customer-value advantage and market success of Libra are enabled by key design innovations throughout and the Libra concept has proven itself in a wide range of scientific applications and demanding industrial settings. Typical Libra-HE Power Stability >4 hours, 8 and 266 nm simultaneously Long term, stable, hands-free operation is enabled by several unique elements. The Vitesse oscillator, pumped by Verdi, is by far the most successful industrial-grade Ti:Sapphire oscillator as proven in hundreds of factory installations. For the shortest pulse duration Libra model, the Vitara-S, our hands-free, wide bandwidth oscillator is utilized. The design also integrates the wellestablished, reliable Evolution pump laser with the E-2 Engine module Coherent s thermally stabilized, high efficiency, regenerative amplifier platform that includes a unique, Ti:Sapphire rod geometry enabling simple, water-only cooling on all Libra models. Finally, a compact, stretcher and compressor support high power, short pulses with unsurpassed beam quality and stability. Libra is available with a choice of pulse energy, pulse duration and repetition-rates The basic Libra offers > mj at khz while the Libra-HE guarantees >4. mj,and the Libra-HE+ is specified at >5. mj. The Libra and Libra-HE are available in, 5 and khz configurations with pulse durations of <5 fs or < fs. The Libra-HE+ is offered at khz with pulse duration options of <4 fs or < fs. All versions provide unsurpassed stability and beam quality, ideal for pumping one or more optical parametric amplifiers Typical Energy Stability.3% rms 2k shots g H D t Superior Reliability & Performance tech.sales@coherent.com

55 Libra One-Box, Ultra-Stable, khz Repetition-Rate, Ti:Sapphire System Key Advantages One-box, compact, computer-controlled system contains integrated Vitesse/Vitara seed laser, Evolution pump laser, regenerative amplifier, stretcher and compressor E-2 Engine - high performance, high reliability, regenerative amplifier module providing the highest energy and efficiency with (M 2 <.3) Unique Ti:Sapphire rod geometry for enhanced thermal management, enabling water-only cooling Thermally-stabilized amplifier platform for long term stability Pulse energy to >5. mj at 8 nm <4 fs, <5 fs and < fs pulse width versions Stability <.5% rms of Specifications Libra Libra-HE Libra-HE+ Center Wavelength (nm)(nominal) 8 Repetition-Rate (khz), 5 or, 5 or Pulse Duration 2 (fs)(fwhm) F-Model < < < USP-Model <5 <5 <4 Energy-per-Pulse (mj) >. at khz >4. at khz >5. at khz >.3 at 5 khz >.8 at 5 khz >.5 at khz >.4 at khz Contrast Ratio 3 >: pre-pulse >: post-pulse Energy Stability 4 (% rms)(8 hrs.) <.5 Beam Diameter 5 (mm)(/e 2 )(nominal) Spatial Mode TEMoo, M 2 <.3 Polarization linear, horizontal Evolution-5 Evolution-3 Evolution-45 Repetition-rate must be specified when ordered and will be optimized prior to shipment. 2 A Gaussian pulse shape de-convolution factor (.7) is used to determine the pulse width from an autocorrelation signal measured by a Coherent SSA (Single-Shot Autocorrelator). Vitara-S used as seed laser for Libra-USP-HE+ (all other versions use Vitesse). 3 Contrast ratio is defined as the ratio between the peak intensity of the output pulse to the peak intensity of any other pulse that occurs greater than ns before or after the output pulse. 4 Under stable environmental conditions, after system warm-up. 5 8 mm (nominal) for Libra-F-HE and Libra-USP-HE at khz. s Typical Warm-Up Stable Power after 5 min. 8 nm and 266 nm Typical Libra-HE Near Field Beam Quality Typical Libra-HE Far-Field Beam Quality IR Power (W) IR Power THG Power THG Power (W) Time (hours) Toll Free: (8) Tel: (48) Superior Reliability & Performance 53

56 Hidra High Energy Hz Ti:Sapphire s of s The Hidra amplifies a nanojoule pulse from a modelocked Ti:Sapphire oscillator up to terawatt peak power at Hz repetition-rate. It is a multi-stage, chirped pulse amplifier consisting of a grating-based pulse stretcher, regenerative amplifier for first-stage amplification, one or more power amplifier stages, followed by a grating-based pulse compressor. With its flexible platform design and a selection of lamp-pumped and diode-pumped solid-state lasers for pumping, all Hidra configurations are upgradable to higher performance. Two standard pumping configurations are available: Hz-only or hybrid pumping. In Hz-only pumping, the entire amplifier (regenerative plus multipass) is pumped by a single Hz lamp-pumped Nd:YAG laser. In hybrid pumping, the regenerative amplifier is pumped with an Evolution diode-pumped khz Nd:YLF laser. The multipass stage(s) are pumped with a lamp-pumped Hz Nd:YAG laser. The main advantage of hybrid pumping is improved stability. The pulse compressor for the mj, 25 mj and 5 mj Hidra systems is contained within the Hidra enclosure. For the mj Hidra, the pulse compressor is a separate unit. This external compressor for the Hidra- is also available with vacuum-compatible mounts as an option. This version requires users to mount the entire compressor inside their own vacuum enclosure to simplify delivery of the terawatt pulses to the experiment. Typical Far-Field Beam Profile for Hidra-5-USP Typical Pulse Width ~36 fs (taken on Hidra-5-USP) Autocorrelation Intensity Time 54 Superior Reliability & Performance tech.sales@coherent.com

57 Hidra High Energy Hz Ti:Sapphire s Key Advantages Two-stage, high-efficiency design: regenerative amplifier plus multipass amplifier Seeded by Vitara, Verdi/Mira or Vitesse oscillators, 25, 5 or mj pulse energy versions 4 fs (USP), 3 fs (F) or ps (P) versions Front-end repetition-rates: ( Hz/2 Hz) or ( khz/5 khz) Superior pulse-to-pulse stability <3% rms TEM beam quality Optional Pulse Slicer for increased nanosecond contrast ratio of Specifications Hidra- Hidra-25 Hidra-5 Hidra- Center Wavelength (nm)(nominal) 8 Repetition-Rate (Hz) Energy-per-Pulse (mj) > >25 >5 > Pulse Duration 2 (FWHM) USP version <4 fs F version <3 fs P version (nominal) ps Energy Stability 3 (% rms) Hybrid pump version <3. Hz pump version <3.5 Contrast Ratio 4 Pre-pulse >: Post-pulse >: Beam Diameter at /e 2 points (mm)(nominal) Spatial Mode 5 TEM, M 2 <.5 Polarization linear, horizontal Seed Source 2 Vitara, Mira/Verdi or Vitesse Green Energy Required 6 (mj) Pulse Compressor 7 Air-compatible (inside main Hidra enclosure) 2 Hz repetition-rate also available but with reduced specifications. First stage (regenerative amplifier) can be pumped with optional Evolution khz green pump laser to improve overall stability and/or provide separate khz repetition-rate Ti:Sapphire output. 2 USP pulse width specification assumes seeding with Vitara. F and P pulse width specifications assume seeding with Vitara, Mira-F or Vitesse. For other seed lasers, please contact factory. A Gaussian pulse shape deconvolution factor (.7) is used to determine the pulse width from an autocorrelation signal measured with a Coherent Model SSA Single-Shot Autocorrelator. For other pulse width specifications, please contact the factory. 3 Measured over shots under stable environmental conditions, after system warm-up. See also note. 4 Contrast ratio (nanosecond) is defined as the ratio between the peak intensity of the output pulse to the peak intensity of any other pulse that occurs more than 2 ns before or after the output pulse. Contrast ratio (nanosecond) with optional Pulse Slicer increases to >6: pre-pulse. Pulse energy specification must be decreased by 5% when optional Pulse Slicer is added. 5 M 2 deviation is less than.2 between X to Y after compression 6 laser must be certified for compatibility with Hidra requirements by Coherent. Beam quality for pump laser must meet certain requirements. Contact the factory for further information. 7 The Pulse Compressors for the Hidra-, -25 and -5 are contained within the main Hidra enclosure. The Hidra- is supplied with an external pulse compressor. Please contact the factory for specific details about this external compressor. As an option, the Hidra- compressor can be supplied with vacuum-compatible parts in a separate, non-vacuum enclosure. In this specific case the customer must supply their own vacuum enclosure for the compressor. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 55

58 RegA High Repetition-Rate, Femtosecond Ti:Sapphire s of s With repetition-rate options to >5 khz, the RegA 9/94/95 provides a unique range of performance for Ti:Sapphire amplifiers. Its use of CW pumping by the market-leading Verdi DPSS laser creates a stable, near diffraction-limited output beam with energy to >6 μj at 25 khz. At high repetition-rates, data acquisition for scientific experiments is faster and throughput is higher in processing applications. The wavelength range of RegA can also be extended by adding a Coherent high repetition-rate optical parametric amplifier (OPA94/98 series). The RegA is specifically designed to amplify seed pulses from a Coherent Vitara, Mira or Vitesse. For oscillator/ amplifier split-pump beam configurations, the specified pump laser for RegA is our Verdi G, G2 or G8, The Vitesse Duo, which integrates the seed oscillator and amplifier pump laser into a single package, forms the most compact configuration. Three versions of RegA are available: the sub-6 fs RegA 9, the sub-6 fs RegA 95, and the sub-4 fs RegA 94. The basic RegA 9 includes the stretching, amplification and compression functions into a single box. The RegA 95 and RegA 94 both use one unit for the amplifier and a second unit containing a stretcher and compressor. The electronic control box provides complete control of pulse timing, delivering a real-time LCD display of amplifier performance. The electronics have the ability to recall and reset any system parameter. The low noise of the Verdi pump laser and high repetition-rate of RegA amplifiers enable data collection with high signal-to-noise ratio in applications such as fourwave mixing or up-conversion. With hundreds of units installed, the RegA system is a well proven ultrafast tool for advanced ultrafast research. Output Power (W) Typical RegA Output Power and Pulse Energy Power - 2W Power - W Power - Vitesse Duo Rep. Rate (khz) Energy - 2W Energy - W Energy - Vitesse Duo Output Energy (µj) 56 Superior Reliability & Performance tech.sales@coherent.com

59 RegA High Repetition-Rate, Femtosecond Ti:Sapphire s Key Advantages CW-pumped regenerative amplifier (Verdi pumping) High repetition-rate, variable to 3 khz standard (>5 khz optional) Versatile electronic control Versions to sub-4 fs, >6 μj Two box configuration available Multiple OPA pumping of Specifications for System Configurations RegA Specifications 2W W 2 Vitesse-Duo 3 Repetition-Rate 4 (khz) Pulse Energy (µj) RegA RegA 9 6 (see note) RegA NA RegA NA RegA 9 RegA 94 RegA 95 Pulse Width (fs)(fwhm) <6 <4 <6 Polarization linear, horizontal, 5: Energy Stability (% rms) < Average Power Drift 8 (% peak-to-peak) <4 Contrast Ratio >5: pre-pulse, >25: post pulse; other pulses >: Beam Quality (M 2 ) <2 9 <.3 <.5 Assumes full 2W of Verdi power used to pump RegA. 2 Assumes full W of Verdi power used to pump RegA. 3 Vitesse Duo is an integrated seed-pump source for RegA. Contains internal W Verdi split to pump Vitesse seed and RegA. Upper limit for repetiton rate is 5 khz. 4 Customer adjustable from khz to 3 khz typical. 5 RegA 9 seeded by Mira or Vitesse. 6 RegA 9 used with optional, external stretcher/compressor available at additional cost. Seeded with Vitara-T, Mira or Vitesse. 7 RegA 94 and 95 designs incorporate external stretcher/compressor and are seeded with Vitara-T. 8 Power drift over one hour (after one-hour warm-up); crystal temperature is controlled with supplied chiller, room temperature stable <± C. 9 <.3 with optional external stretcher/compressor. s Autocorrelation Intensity Autocorrelation of RegA 94 Pulses Deconvolved Single-Shot Pulse FWHM = 3 fs Time Toll Free: (8) Tel: (48) Superior Reliability & Performance 57

60 OPerA Solo Fully Integrated, Computer-Controlled Femtosecond Optical Parametric of s The OPerA Solo is a fully integrated, computer-controlled femtosecond optical parametric amplifier (OPA) that extends the wavelength accessibility of the Legend Elite and Libra amplifiers from 9 nm to 2 µm. As the first unit of its kind, the OPerA Solo integrates all pump conditioning optics, wavelength extension options and wavelength separation optics within one enclosure. This makes the OPerA Solo a very compact, easy-to-use and stable device. When pumped by the Legend Elite or Libra amplifier, the OPerA Solo system provides a unique, compact and reliable approach for high-performance tunable ultrafast applications. The OPerA Solo design incorporates well-proven TOPAS technology in the white-light seeded, pre-amplifier followed by a power amplifier. In the sum-frequencymixing configuration the OPerA Solo uses a fraction of the 8 nm pump beam directly from the Legend Elite output beam for mixing with the OPA signals. This fresh pump beam feature enables superior spatial, spectral and temporal beam quality compared to designs that use the residual portion of the 8 nm pump beams. Typical OPerA Solo Tuning Curve Legend Elite USP-K-HE (3.3 mj) Power (mw) Signal Idler SHI SHS SFI SFS FHI FHS SHSFI SHSFS NDFG NDFG2,, Wavelength (nm) 58 Superior Reliability & Performance tech.sales@coherent.com

61 OPerA Solo Fully Integrated, Computer-Controlled Femtosecond Optical Parametric Key Advantages Fully integrated one-box system Convenient computer-controlled tuning Options for 9 nm to 2 µm tuning Configurations to accommodate pulse widths from all Coherent khz femtosecond amplifiers (<3 fs, <5 fs, <4 fs, <35 fs, <25 fs) Whitelight-seeded pre-amplifier for lowest noise Fresh pump configuration for optimum spatial, temporal and spectral mixing performance Multiple OPAs may be pumped with a single khz amplifier of Specifications,2 Options 3 Beam Wavelength Range Pulse Energy Polarization <5 fs pump <3 fs pump OPerA Solo 4 Signal 4 to 6 nm 22 µj (S+I) V Idler 6 to 26 nm 22 µj (S+I) H SH Package SHI 8 to 5 nm V SHS 58 to 8 nm >3 µj >5 µj V SF Package SFI 533 to 58 nm >3 µj >5 µj V SFS 48 to 533 nm >4 µj >7 µj V FH Package FHI 4 to 48 nm H FHS 29 to 4 nm >5 µj > µj H SHSF Package SH (SFI) 266 to 295 nm H SH (SFS) 24 to 266 nm >3 µj >8 µj H NDFG Package NDFG 2.6 to µm 5 >2 µj at 4 µm >8 µj at 4 µm H >.5 µj at 9 µm >.5 µj at µm NDFG2 5 to 2 µm 6 > µj at 5 µm >4 µj at 5 µm H >. µj at 5 µm >.3 µj at 5 µm All specifications are based on pumping with mj from Legend Elite or Libra systems at khz (contact factory for other pump systems). Specifications for harmonic wavelengths pumped by Legend Elite USX and Legend Elite Duo USX models are 25% lower. 2 Energy scales linearly with pump in range.3 mj to 4.5 mj for <3 fs pump and.3 mj to 4 mj for <5 fs pump. 3 Energies given at peak of tuning ranges. SH/SF/FH/SHSF wavelength extension options listed include all mixing crystals listed in preceding options (e.g., SHSF options includes crystals, etc., to tune from 24 to 5 nm). Contact factory for tuning down to 9 nm. 4 Signal pulse width is (.7 to.) x pump for <3 fs pump duration, ( to.5) x pump for <5 fs pump duration. 5 DFG tuning range is 2.6 μm to 9 μm for <5 fs pump. DFG pulse width is ( to.5) x pump for <3 fs pump and (.5 to 2) x pump for <5 fs pump. 6 DFG2 tuning range is 5 μm to 5 μm for <5 fs pump. DFG2 pulse width is ( to 2) x pump for <3 fs pump. Near Field Typical OPerA Solo Beam Profile 5 nm Sum Frequency Generation Far Field s Toll Free: (8) Tel: (48) Superior Reliability & Performance 59

62 TOPAS Computer-Controlled, Modular Optical Parametric of s TOPAS* is a computer-controlled optical parametric amplifier (OPA) used to extend the tuning range of the Legend Elite, Legend Elite Cryo PA, Hidra, and Libra ultrafast amplifiers. Femtosecond and picosecond models are available and high energy versions can accommodate pump energies of more than mj. The whitelight seeding technology in the TOPAS is featured on all Coherent femtosecond khz models to ensure the lowest output noise performance. OPA picosecond systems use superfluorescence seeding for maximum efficiency at narrow bandwidths. TOPAS employs a modular design with external beam-conditioning optics and wavelength extension options to extend the standard tuning range from 9 nm to 2 µm. *TOPAS is a registered trademark of Light Conversion. Pulse Energy (µj) Typical Tuning Curve (pumped by mj, khz, 8 nm Legend Elite).,, Wavelength (nm) Signal (8 to 62 nm) Idler (62 to 2484 nm) NDFG (2.4 to µm) SHI (8 to 8 nm) SHS (59 to 8 nm) SFI (533 to 59 nm) SFS (478 to 533 nm) FHI (45 to 478 nm) FHS (295 to 45 nm) SHSFI (266.5 to 295 nm) SHSFS (239 to nm) 6 Superior Reliability & Performance tech.sales@coherent.com

63 TOPAS Computer-Controlled, Modular Optical Parametric Key Advantages Computer-controlled tunable output Energy conversion >3% to 35% to parametric light Low output noise due to whitelight seeding Modular option for extended tuning from 9 nm to 2 µm: Standard tuning is from 5 nm to 26 nm Configurations to accommodate pulse widths from all Coherent khz femtosecond amplifiers (<3 fs, <5 fs, <4 fs, <35 fs, <25 fs) Multiple OPAs can be pumped with one Ti:Sapphire amplifier of High energy (HE) models available: Up to mj for Legend Elite Cryo PA and Hidra amplifiers Picosecond models available Specifications,2 Options 3 Beam Wavelength Range Pulse Energy Polarization <5 fs pump <3 fs pump TOPAS-8-fs 4 Signal 4 to 6 nm 25 μj (S+I) V Idler 6 to 26 nm 25 μj (S+I) H TOPAS-8-fs-VIS SHI 8 to 5 nm V SHS 58 to 8 nm >3 µj >8 µj H SFI 533 to 58 nm >3 μj >6 μj V TOPAS-8-fs-BLUE SFS 48 to 533 nm >4 μj >9 μj V TOPAS-8-fs-UV FHI 4 to 48 nm H FHS 29 to 4 nm >5 μj >5 μj V TOPAS-8-fs-UV2 SH (SFI) 266 to 295 nm H SH (SFS) 24 to 266 nm >3 μj >8 μj H TOPAS-8-fs-IR 5,6 DFG 2.6 to μm >2 μj at 4 μm >8 μj at 4 μm H >.5 μj at 9 μm >.5 μj at μm H DFG2 5 to 2 μm 6 > μj at 5 μm >4 μj at 5 μm H >. μj at 5 μm >.3 μj at 5 μm H All specifications are based on pumping with mj from Legend Elite or Libra systems at khz (contact factory for other pump systems). Specifications for harmonic wavelengths pumped by Legend Elite USX and Legend Elite Duo USX models are 25% lower. 2 Energy scales linearly with pump in range.3 mj to 4 mj for <3 fs pump and.3 mj to 3.5 mj for <5 fs pump. 3 Energies given at peak of tuning ranges. VIS/BLUE/UV wavelength extension options listed include all mixing crystals listed in preceding options (e.g., TOPAS-UV2 options includes crystals, etc., to tune from 24 to 5 nm). Contact factory for tuning down to 9 nm. 4 Signal pulse width is (.7 to.) x pump for <3 fs pump duration, ( to.5) x pump for <5 fs pump duration. 5 DFG tuning range is 2.6 μm to 9 μm for <5 fs pump. DFG pulse width is ( to.5) x pump for <3 fs pump and (.5 to 2) x pump for <5 fs pump. 6 DFG2 tuning range is 5 μm to 5 μm for <5 fs pump. DFG2 pulse width is ( to 2) x pump for <3 fs pump. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 6

64 TOPAS-Prime Computer-Controlled, Modular Optical Parametric of s TOPAS*-Prime is a computer-controlled optical parametric amplifier (OPA) providing the ability to extend the tuning ranges of the Legend Elite and Libra ultrafast amplifier families. All of the best features from the TOPAS-8-fs are retained in the TOPAS-Prime including white light seeding for lowest output noise performance. In addition, TOPAS-Prime employs a monolithic housing for improved mechanical stability. TOPAS-Prime uses a modular design and wavelength extension packages to achieve a tuning range of 9 nm to 2 µm. The standard TOPAS-Prime model accepts pulse energies up to 3.5 mj, input pulse energies up to 5 mj can be achieved with the TOPAS-PrimePlus model. *TOPAS is a registered trademark of Light Conversion. Pulse Energy (µj) Typical Tuning Curve (pumped by mj, khz, 8 nm Legend Elite).,, Wavelength (nm) Signal (8 to 62 nm) Idler (62 to 2484 nm) NDFG (2.4 to µm) SHI (8 to 8 nm) SHS (59 to 8 nm) SFI (533 to 59 nm) SFS (478 to 533 nm) FHI (45 to 478 nm) FHS (295 to 45 nm) SHSFI (266.5 to 295 nm) SHSFS (239 to nm) 62 Superior Reliability & Performance tech.sales@coherent.com

65 TOPAS-Prime Computer-Controlled, Modular Optical Parametric Key Advantages Monolithic housing for mechanical stability Computer-controlled tunable output Energy conversion >3% to 35% to parametric light Low output noise due to whitelight seeding Optional fresh pump channel for improved sum frequency performance Modular option for extended tuning from 9 nm to 2 µm: Standard tuning is from 5 nm to 26 nm Configurations to accommodate pulse widths from all Coherent khz femtosecond amplifiers (<3 fs, <5 fs, <4 fs, <35 fs, <25 fs) Multiple OPAs can be pumped with one Ti:Sapphire amplifier High energy (HE) models available: Up to mj for Legend Elite Cryo PA and Hidra amplifiers of Specifications,2 Options 3 Beam Wavelength Range Pulse Energy Polarization <5 fs pump <3 fs pump TOPAS-Prime 4 Signal 4 to 6 nm 25 μj (S+I) V Idler 6 to 26 nm H TOPAS-Prime-VIS 5 SHI 8 to 5 nm >3 µj >8 µj V SHS 58 to 8 nm H SFI 533 to 58 nm >3 μj >5 μj V TOPAS-Prime-BLUE 5 SFS 48 to 533 nm >4 μj >7 μj V TOPAS-Prime-UV FHI 4 to 48 nm H FHS 29 to 4 nm >5 μj >5 μj V TOPAS-Prime-UV2 SH (SFI) 266 to 295 nm H SH (SFS) 24 to 266 nm >3 μj >8 μj H TOPAS-Prime-NDFG/2 DFG 2.6 to μm 6 >2 μj at 4 μm >8 μj at 4 μm H >.5 μj at 9 μm >.5 μj at μm H DFG2 5 to 2 μm 7 > μj at 5 μm >4 μj at 5 μm H >. μj at 5 μm >.3 μj at 5 μm H All specifications are based on pumping with mj from Legend Elite or Libra systems at khz (contact factory for other pump systems). Specifications for harmonic wavelengths pumped by Legend Elite USX and Legend Elite Duo USX models are 25% lower. 2 Energy scales linearly with pump in range.3 mj to 4 mj for <3 fs pump and.3 mj to 3.5 mj for <5 fs pump. TOPAS-PrimePlus model extends pump energy input to 5 mj for both <5 and <3 fs models. 3 Energies given at peak of tuning ranges. VIS/BLUE/UV wavelength extension options listed include all mixing crystals listed in preceding options (e.g., TOPAS-Prime-UV-2 options includes crystals, etc., to tune from 24 to 5 nm). Contact factory for tuning down to 9 nm. 4 Signal pulse width is (.7 to.) x pump for <3 fs pump duration, ( to.5) x pump for <5 fs pump duration. 5 With optional fresh pump package. Specifications for non-fresh pump option are unchanged at <5 fs and for <3 fs; SFI = >6 uj, SFS = >9 uj. 6 DFG tuning range is 2.6 μm to 9 μm for <5 fs pump. DFG pulse width is ( to.5) x pump for <3 fs pump and (.5 to 2) x pump for <5 fs pump. 7 DFG2 tuning range is 5 μm to 5 μm for <5 fs pump. DFG2 pulse width is ( to 2) x pump for <3 fs pump. s Toll Free: (8) Tel: (48) Superior Reliability & Performance 63

66 SHBC/TOPAS-4 Computer-Controlled, Line Narrowed, Optical Parametric of s The combination of SHBC and TOPAS*-4 provides a unique accessory for generating narrow-band (<2 cm - ), tunable radiation when pumped with the 8 nm output from a femtosecond Legend Elite or Libra amplifier. When used in conjunction with an additional standard femtosecond OPA, it offers the potential to provide both femtosecond and picosecond tunable beams simultaneously using a single femtosecond amplifier. The SHBC (Second Harmonic Bandwidth Compressor), converts the wide bandwidth beam at 8 nm from the femtosecond ultrafast amplifier (purchased separately) to a narrow bandwidth beam at 4 nm. This 4 nm beam is then used to pump the TOPAS- 4-ps-WL picoseond OPA model to generate tunable, narrow bandwidth beam from 48 nm to 26 nm. *TOPAS is a registered trademark of Light Conversion. Energy (µj) TOPAS-4-ps-WL Typical Tuning Curve (pumped by output from SHBC) Signal + Idler Signal Idler : SHBC, 4 nm, 7.5 cm,.85 mj SHBC pump, Legend Elite 8 nm, ~ fs,.6 mj Wavelength (nm) 64 Superior Reliability & Performance tech.sales@coherent.com

67 SHBC/TOPAS-4 Computer-Controlled, Line Narrowed, Optical Parametric Key Advantages Converts 8 nm femtosecond pump beam to tunable narrow-band output Potential for simultaneous femtosecond and picosecond beams using one femtosecond, Ti:Sapphire amplifier Computer-controlled tunable output 48 nm to 26 nm <2 cm - bandwidth Energy conversion >2% conversion to parametric light of Specifications SHBC Output Wavelength (nm)(nominal) 4 Conversion Efficiency (%) >25 Spectral Width (cm - ) < Energy Stability 2 (% rms) <3 Polarization Legend Elite, Libra linear, horizontal TOPAS-4-ps-WL SHBC Wavelength Range 3 (nm) 48 to 26 Pulse Energy 4 (signal + Idler at peak, µj) >5 Pulse Duration Spectral Width (cm - )(5 nm to 73 nm, 87 nm to 24 nm) <2 Energy Stability 2 (% rms)(5 nm to 7 nm, 9 nm to 2 nm) <6 (.5 - ) x pump pulse width Polarization Signal linear, vertical Idler linear, horizontal with.3 mj to 2 mj, 35 fs to 2 fs from Legend Elite or Libra at khz (contact factory for other systems). 2 Under stable environmental conditions. 3 Some energy and spectrum modulation possible in the range 73 nm to 87 nm. 4 Assuming 25 µj, 4 nm pump from SHBC. Scales linearly with pump in range.3 mj to mj. s SHBC Output Spectrum TOPAS-4-ps-WL Output Spectrum.. Wavelength: 48 nm FWHM:.33 nm (4.3 cm - ) Wavelength (nm) Wavelength (nm) Toll Free: (8) Tel: (48) Superior Reliability & Performance 65

68 Harmonic Generator System (HGS) Second-, Third-, and Fourth-Harmonic for Ti:Sapphire s of s The HGS accessory provides extremely convenient second-, third- or fourth-harmonic output for khz Legend Elite and Libra Ti:Sapphire amplifiers, and Hz Hidra Ti:Sapphire amplifiers. Second- (HGS-D) and third- (HGS-T) harmonic outputs are accessible from a single compact unit. A second enclosure is added for fourth-harmonic (HGS-F) generation. The HGS employs collinear mixing in high-damagethreshold BBO crystals for high efficiency and ease of use. Crystal rotation and optical delay stages are manually adjustable, and all crystals, focussing optics, dichroic wavelength separation mirrors, etc., are included. The near-diffraction limited beam quality and demonstrated stability of both pulse width and beam pointing from Coherent amplifiers ensure optimum performance at the harmonic wavelengths. Key Advantages Simple collinear mixing configurations Compatible with Coherent 35 fs to 3 fs, and.5 ps to 2 ps Ti:Sapphire amplifiers High-damage-threshold, high-conversionefficiency BBO crystals Includes wavelength separation mirrors, waveplates, focusing optics, etc. Standalone enclosure two enclosures are required for fourth harmonic Specifications HGS-D HGS-T HGS-F Conversion Efficiency (%, from 8 pump, fsec) 35 5 Power Stability (%, rms) Superior Reliability & Performance tech.sales@coherent.com

69 Single-Shot Autocorrelator (SSA) Pulse Width for Ultrafast Systems of The SSA accessory is designed for use over a broad range of energies and wavelengths. Available in configurations to measure femtosecond or picosecond pulses, this is an accurate and versatile tool compatible with both commercial amplifier systems Legend Elite, Libra and Hidra and with home-built amplifier systems. Two femtosecond models are available (SSA-F and Hi- Res SSA) depending on the pulse lengths to be measured. The picosecond option (SSP) is available with the SSA-F model. The SSA splits laser pulses into two beams that are then non-colinearly frequency-doubled in a non-linear crystal. In the femtosecond configuration the relative wavefront tilt produces a spatial time delay in the frequency-doubled signal, which results in an autocorrelation of the temporal intensity profile. In picosecond operation one mirror is replaced with a diffraction grating for additional wavefront tilt. In both operations the autocorrelation signal is detected by a CCD array and is Key Advantages Measures temporal width of amplified pulses Broad pulse width range: from 2 fs to 2 ps Wavelength coverage in femtosecond operation from 68 nm to nm Indexed internal mirror allows beam to be sampled without disrupting experiments available for display on an oscilloscope or as a measurement by a computer DAC card. The SSA s indexed internal mirror configuration allows convenient sampling of pulses without disrupting experiments. The compact and rugged SSA also can be left in place after initial installation for accurate in-line measurements. s Specifications SSA Femtosecond Picosecond SSA-F Hi-Res SSA SSA-F w/ssp Wavelength (nm) 68 to 68 to Sampling Rate (Hz) Pulse Length (fs) 5 to 5 2 to 5 5 to 2 Range (ps) 2 34 at 8 nm Resolution (fs) at 8 nm In picosecond mode, the range and resolution are wavelength-dependent. Contact factory for details. Toll Free: (8) Tel: (48) Superior Reliability & Performance 67

70 OPA 94/945 and 98/985 Optical Parametric s for RegA 9/95 Regenerative of s The OPA 94/945 and OPA 98/985 family of optical parametric amplifiers extends the wavelength coverage of the RegA 9/RegA 94 and RegA 95 high repetition-rate (25 khz) regenerative amplifiers into the visible and infrared spectral ranges. These OPAs are highly efficient and easy-to-use passive devices. Pulses from the RegA amplifier are split into two beams. One beam produces whitelight continuum to seed the parametric amplification process while the other beam pumps the BBO non-linear crystal. To allow access to both visible and near-infrared output the OPA 94/945 is pumped with the second harmonic (4 nm) from the RegA, while the OPA 98/985 is pumped with the RegA s 8 nm beam. Key Advantages Variable repetition-rate Multiple synchronized output beams Whitelight continuum seed for ease of tuning Difference-frequency generation (DFG) options extend tuning to the mid-ir region Multiple outputs are available to provide signal and idler beams from the parametric process, as well as residual beams from the whitelight continuum and RegA pump beams. 68 Specifications OPA 94 OPA 945 OPA 98 OPA 985 Repetition-Rate (khz) 25 Pulse Energy (nj) 8 6 Average Power (mw) 2 4 Signal Output (nm) 48 to 7 2 to 6 Idler Output (nm) 933 to 23 6 to 24 Pulse Width <225 fs AC See Note 4 <225 fs See Note 4 Noise 2 (%) ±2. Stability 3 (%) ±2. M 2 <2. Specifications based on output of one OPA, W Verdi pumping a RegA 9/95, and either Mira/Verdi or Vitesse seeding. Same specifications apply for two simultaneously pumped OPAs at khz. 2 Peak-to-peak noise measured in one hour at Hz to Hz. 3 Power drift over one hour (after 5-minute warm-up); crystal temperature controlled with supplied chiller; room temperature stable <± C. 4 Compressible to pump pulse width using external pulse compressor (not provided). Superior Reliability & Performance tech.sales@coherent.com

71 DFG 98/985 Difference-Frequency Generators for the OPA 98/985 of The DFG 98/985 are wavelength extension accessories for the OPA 98 and OPA 985 Optical Parametric s. Both the 98 DFG and the 985 DFG extend the tuning of Coherent OPAs into the mid-infrared range from 2.55 µm to > µm. This level of operation makes the DFG 98/985 the industry s only high repetition-rate sources for ultrafast spectroscopy in the mid-ir range. Ease of tuning is achieved by simple adjustment of external control knobs. Key Advantages Tunable solid-state source for mid-ir operation Compatible with OPA 98 and OPA 985 optical parametric amplifiers Repetition-rates up to 3 khz Ease of wavelength tuning s Specifications DFG 98/985 Power 2W (split from Verdi G8) W, Verdi DFG Conversion Efficiency at 4 μm >2%, 25 khz >.5%, khz DFG Unit (L x W x H) 58.4 x 35.6 x 8.4 cm (23 x 4 x 7.25 in.) Input Beam Height 2 cm (4.75 in.) above table Output Beam Height.2 cm (4.4 in.) above table Conversion efficiency from signal beam at 33 nm based on W or 2W pump power from Verdi into RegA. Output specified at 4 µm only. Toll Free: (8) Tel: (48) Superior Reliability & Performance 69

72 CEP Stabilizer for Legend Elite Carrier to Envelope Phase (CEP) Stabilization for Legend Elite of s The Legend Elite CEP Stabilizer is a state-of-the-art Carrier-to-Envelope Phase stabilizer accessory designed exclusively for the Legend Elite amplifiers. Applications such as High Harmonics Generation and Attosecond Science require CEP stabilized ultrafast pulses, generated by the Vitara oscillator, to be amplified up to the millijoule level of energy by Legend Elite amplifiers while conserving the CEP stability. The Legend Elite CEP stabilizer includes an active feedback control to lock the phase velocity of the oscillating light field to the group velocity of the phase envelope. Thus, for ultra-short pulses consisting of only a few optical cycles, the peak of the oscillat ing electrical field can be maximized under the phase envelope. At the heart of the Legend Elite CEP is a separate phase detection module which includes an f-to-2f interferometer. An octave-spanning optical spectrum is generated by focusing a small part of the Legend Elite beam on a sapphire plate. The red end of this spectrum is frequency-doubled and colinearly combined with the blue end of this same broad spectrum. The resulting spectral interference fringes are measured, on every shot, by an analog detector which generates a signal to stabilize and control the Carrier- Envelope Phase by making adjustments in the Legend Elite amplifier. With the CEP stabilized Verdi pumped Vitara and Evolution pumped Legend Elite, Coherent is the first and only company to offer a complete CEP stabilized ultrafast amplifier system designed and built by a single manufacturer. 7 Superior Reliability & Performance tech.sales@coherent.com

73 CEP Stabilizer for Legend Elite Carrier to Envelope Phase (CEP) Stabilization for Legend Elite Key Advantages RMS CEP stability typically sub-2 mrad ( shots integration) f-to-2f collinear interferometer in separate module Seeded by our Verdi pumped Vitara CEP Regenerative amplifier technology for superior mode quality, beam pointing and output energy stability Complete CEP amplifier system from a single manufacturer Available for Legend Elite USX and USP models of GUI for Legend Elite CEP s 3 Legend Elite CE Phase Stability CE Phase (rad) 2-54 mrad (rms) Time (minutes) Toll Free: (8) Tel: (48) Superior Reliability & Performance 7

74 Matrix of Recommendations Below and on the following page are recommendations for selecting the power and energy measurement tools for your ultrafast setup. Our power sensors measure the output of all Coherent pump lasers, amplifiers and oscillators, while our pulse energy measurement systems are designed for pump sources or oscillators having repetition-rates less than khz. And our energy sensors give you immediate feedback when peaking the output of your ultrafast system. All Coherent power and energy measurement products offer superior performance for applications requiring the precise pulse energy specifications. of s Meter, Sensor and Power Meter Power Sensor Energy Meter Energy Sensor Verdi G2, G5, G7, G8 FieldMaxII-TO PM - - Verdi G, G2, G5, G8 FieldMaxII-TO PM3 - - Evolution-5/3 FieldMaxII-TO PM3 LabMax-TOP J-25MT-KHZ Evolution-45 FieldMaxII-TO PM5 LabMax-TOP J-5MT-KHZ 2 Evolution-HE FieldMaxII-TO PM5 - - Vitara FieldMaxII-TO PM or PS Mira-9 FieldMaxII-TO PM - - Mira-HP FieldMaxII-TO PM - - Chameleon FieldMaxII-TO PM - - Vitesse FieldMaxII-TO PM or PS Mira-OPO FieldMaxII-TO PS - - Chameleon Compact OPO/OPO-Vis FieldMaxII-TO PS - - s 4 Legend Elite HE+(F, P, USP, USX) FieldMaxII-TO PM LabMax-TOP J-25MT-KHZ Legend Elite Duo HE+ (F, P, USP, USX) FieldMaxII-TO PM3 LabMax-TOP J-25MT-KHZ Legend Cryo PA FieldMaxII-TO PM3 LabMax-TOP J-25MT-KHZ Libra FieldMaxII-TO PM LabMax-TOP J-25MT-KHZ RegA 9/95 FieldMaxII-TO PS Hidra FieldMaxII-TO PMV FieldMaxII-TOP J-5MB-YAG OPerA Solo FieldMaxII-TO PM or PS 3 LabMax-TOP J-MT-KHZ (< mj pump) J-MB-HE (> mj pump) TOPAS/TOPAS-Prime FieldMaxII-TO PM or PS 3 LabMax-TOP J-MT-KHZ (< mj pump) J-MB-HE (> mj pump) With medium heat sink. 2 With large heat sink. 3 The PS is recommended when making higher resolution or low power measurements. 4 See above for sensors to measure pump lasers. 72 Superior Reliability & Performance tech.sales@coherent.com

75 Ultrafast Chart Mira 9 Mira HP Vitara-T/ Vitara-S Vitesse Chameleon Vitara-T HP Harmonic Generator X X X X X X Mira-OPO X X X Pulse Picker X X X X X X Pulse Switch Cavity Dumper X Compact Pulse Compressor (CPC) X X X X X X Pulse Compressors (SPO/SPO2) X X X X X X Chameleon PreComp X X X Synchrolock-AP X X X Vitara CEP X of Ultrafast s Chart Legend Elite/ Legend Elite Duo Hidra RegA Elite HE/Libra Harmonic Generators (HGS) X X X OPerA Solo X X TOPAS X X X TOPAS-HE X X OPA 94/945 and 98/985 X DFG 98/985 X Single-Shot Autocorrelator (SSA) X X X Up to 3.5 mj pump beam. s Ultrafast s Seed Chart Vitara-S Vitara-T Vitara-T HP Vitesse Mira F Chameleon Legend Elite USX X Legend Elite USP/Hidra USP X X X Legend Elite F/Hidra F X X X X X X Legend Elite P/Hidra P X X X X X RegA 9 Call Call Call X X Factory Factory Factory RegA 95/94 X X X At <8 fs. Toll Free: (8) Tel: (48) Superior Reliability & Performance 73

76 Ultrafast Sample Configurations* Vitara + Hidra 5 Hybrid + Evolution 5 + YAG Vitara + Legend Elite + TOPAS Hz YAG Vitara Vitara Legend Elite HE+ Hidra 5 Hybrid Evolution 5 of Topas-C 4' X 8' 5' X ' Vitara + Legend Elite + HGS Vitara + Legend Elite DUO + Evolution 3/45 (optional) Vitara Vitara Legend Elite Duo HE+ Legend Elite HE+ HGS Evolution 3 s 4' X 8' 4' X 8' Vitara + Legend Elite + OPerA Solo Vitara + Legend Elite DUO + 2X OPerA Solo Vitara Vitara Legend Elite Duo HE+ Legend Elite HE+ OPerA Solo OPerA Solo OperA Solo 4' X ' 4' X 8' Vitara + Legend Elite + Cryo PA Vitara Legend Elite Cryo PA Legend Elite HE+ 4' X 2' *Contact Coherent for additional table layout configurations. 74 Superior Reliability & Performance tech.sales@coherent.com

77 Ultrafast Sample Configurations* Vitara + RegA 95 + OPA DFG 985 Vitara + Hidra 5 + YAG Vitara Verdi G Hz YAG EC 95 RegA 95 OPA 985 of Vitara Hidra 5 4' X 8' Verdi G + Mira + Legend Elite 5' X 8' Mira Libra + 2 x OPerA Solo OPerA Solo Legend Elite HE+ Verdi G Libra OPerA Solo s 4' X 8' Verdi G + Mira + PP 92 + THG 93 4' X 8' Vitesse Duo + RegA 9 + OPA 94 Verdi G Vitesse Duo Mira SHG/THG PP 92 RegA 9 4' X 8' OPA 94 Verdi G8 + Mira HP + 2 x Mira OPO 4' X 8' Mira OPO Verdi G8 Mira HP Mira OPO 4' X 8' *Contact Coherent for additional table layout configurations. Toll Free: (8) Tel: (48) Superior Reliability & Performance 75

78 How to Contact Us Contact Us by Phone Coherent, Inc. (8) or (48) Benelux: +3 (3) China: +86 () France: +33 () 838 Germany: +49 (67) Italy: +39 (2) Japan: +8 (3) Korea: +82 (2) Taiwan: +886 (3) United Kingdom: +44 () Contact Us by Products: tech.sales@coherent.com : lmc.sales@coherent.com Service: product.support@coherent.com 76 All Coherent product names are trademarks of Coherent, Inc. *All products indicated by an asterisk are registered trademarks of their respective companies.

79 Visit the Coherent Website for more information about how Coherent can enable your ultrafast laser application. Use the Product and Application Finders below to quickly get more helpful details. Extensive Finder Powerful Diode and Diode Module Finder Comprehensive Meter and Sensor Finder Enhanced Application Finder Brochures, Tech Notes, Technical Illustrations, Videos, Data Sheets Toll Free: (8) Tel: (48) Fax: (8) 362-7

80 Coherent, Inc. 5 Patrick Henry Drive Santa Clara, CA 9554 United States Toll Free: Tel: (48) Fax: (48) China Coherent Inc., Beijing Room 25 Yin Gu Building No. 9 Beisihuan Xi Road Haidian District Beijing, 8, China Tel: Fax: France Coherent France Parc Technopolis 3, Avenue du Canada Bâtiment Zeta 9978 Courtaboeuf cedex France Tel: Fax: Germany Coherent GmbH Dieselstraße 5b D-6487 Dieburg Germany Tel: Fax: Italy Coherent Italia Via Borgese, 4 Milano, 254 Italy Tel: Fax: Japan Coherent Japan, Inc. Toyo MK Building Toyo Koto-ku, Tokyo 35-6 Japan Tel: Fax: Korea No., Eagle Town 278-2, 3 dong Seongsu 2 ga Seongdong-gu, Seoul , South Korea Tel: Netherlands Coherent B.V. Smart Business Park Kanaalweg 8A 3526 KL Utrecht Netherlands Tel: Fax: Taiwan Coherent Taiwan 2F-5, No. 38. Taiyuan St. Zubei City, Hsinchu County 3265 Taiwan Tel: United Kingdom Coherent UK Ltd. St Thomas Place Cambridgeshire Business Park Ely CB7 4EX England Tel: Fax: Printed in the U.S.A. MC M62Rev.B Copyright 22 Coherent, Inc.

Ultrafast Laser Systems

Ultrafast Laser Systems Ultrafast Systems 27 Product Catalog Superior Reliability & Performance The Industrial Revolution in Ultrafast Science Courtesy of Sarah Crowe and Graham Ellis-Davies, Mount Sinai School of Medicine. At

More information

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance. Vitara Features:

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance. Vitara Features: Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family Vitara is the new industry standard for hands-free, integrated, ultra-broadband, flexible ultrafast lasers. Representing the culmination

More information

High Power and Energy Femtosecond Lasers

High Power and Energy Femtosecond Lasers High Power and Energy Femtosecond Lasers PHAROS is a single-unit integrated femtosecond laser system combining millijoule pulse energies and high average powers. PHAROS features a mechanical and optical

More information

Mira OPO-X. Fully Automated IR/Visible OPO for femtosecond and picosecond Ti:Sapphire Lasers. Superior Reliability & Performance. Mira OPO-X Features:

Mira OPO-X. Fully Automated IR/Visible OPO for femtosecond and picosecond Ti:Sapphire Lasers. Superior Reliability & Performance. Mira OPO-X Features: Fully Automated IR/Visible OPO for femtosecond and picosecond Ti:Sapphire Lasers Mira OPO-X is a synchronously pumped, widely tunable, optical parametric oscillator (OPO) accessory that dramatically extends

More information

High-Power Femtosecond Lasers

High-Power Femtosecond Lasers High-Power Femtosecond Lasers PHAROS is a single-unit integrated femtosecond laser system combining millijoule pulse energies and high average power. PHAROS features a mechanical and optical design optimized

More information

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance Vitara Automated for hands-free, reliable operation Computer controlled bandwidth Computer tunable center wavelength PowerTrack active optimization 3 fs pulsewidth capability Low noise Integrated

More information

The All New HarmoniXX Series. Wavelength Conversion for Ultrafast Lasers

The All New HarmoniXX Series. Wavelength Conversion for Ultrafast Lasers The All New HarmoniXX Series Wavelength Conversion for Ultrafast Lasers 1 The All New HarmoniXX Series Meet the New HarmoniXX Wavelength Conversion Series from APE The HarmoniXX series has been completely

More information

taccor Optional features Overview Turn-key GHz femtosecond laser

taccor Optional features Overview Turn-key GHz femtosecond laser taccor Turn-key GHz femtosecond laser Self-locking and maintaining Stable and robust True hands off turn-key system Wavelength tunable Integrated pump laser Overview The taccor is a unique turn-key femtosecond

More information

Genesis CX STM-Series

Genesis CX STM-Series Coherent s unique Optically Pumped Semiconductor Laser (OPSL) technology powers the Genesis CX-STM Series, providing up to 250 mw of UV laser light or up to 10W of visible laser light from either OEM or

More information

Aurora II Integra OPO Integrated Nd:YAG Pumped Type II BBO OPO

Aurora II Integra OPO Integrated Nd:YAG Pumped Type II BBO OPO L i t r o n T o t a l L a s e r C a p a b i l i t y Aurora II Integra OPO Integrated Nd:YAG Pumped Type II BBO OPO The Litron Aurora II Integra is an innovative, fully motorised, type II BBO OPO and Nd:YAG

More information

Features. Applications. Optional Features

Features. Applications. Optional Features Features Compact, Rugged Design TEM Beam with M 2 < 1.2 Pulse Rates from Single Shot to 15 khz IR, Green, UV, and Deep UV Wavelengths Available RS232 Computer Control Patented Harmonic Generation Technology

More information

APE Autocorrelator Product Family

APE Autocorrelator Product Family APE Autocorrelator Product Family APE Autocorrelators The autocorrelator product family by APE includes a variety of impressive features and properties, designed to cater for a wide range of ultrafast

More information

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters. THE TUNABLE LASER LIGHT SOURCE HÜBNER Photonics Coherence Matters. FLEXIBILITY WITH PRECISION is the tunable laser light source for continuous-wave (cw) emission in the visible and near-infrared wavelength

More information

Atlantic. Industrial High Power Picosecond Lasers. features

Atlantic. Industrial High Power Picosecond Lasers. features Atlantic Industrial High Power Picosecond Lasers lasers have been designed as a versatile tool for a variety of industrial material processing applications. They are compact, OEM rugged, with up to 8 W

More information

PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models

PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models PGx1 PGx3 PGx11 PT2 Transform Limited Broadly Tunable Picosecond OPA optical parametric devices employ advanced design concepts in order to produce broadly tunable picosecond pulses with nearly Fourier-transform

More information

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS 1 picoemerald Two Colors in One Box Microscopy and Spectroscopy with a Tunable Two-Color Source CARS and SRS microscopy

More information

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability Photonics Industries DS Series of UV (351/355 nm) diode pumped solid-state Q-switched lasers offer a compact, hands-free system with the long-term reliability that the manufacturing industry demands. Utilizing

More information

TIGER Femtosecond and Picosecond Ti:Sapphire Lasers. Customized systems with SESAM technology*

TIGER Femtosecond and Picosecond Ti:Sapphire Lasers. Customized systems with SESAM technology* TIGER Femtosecond and Picosecond Ti:Sapphire Lasers Customized systems with SESAM technology* www.lumentum.com Data Sheet The TIGER femtosecond and picosecond lasers combine soliton mode-locking, a balance

More information

Lasers for Life Sciences

Lasers for Life Sciences Lasers for Life Sciences 2015 Laser Overview Superior Reliability & Performance Lasers for Life Sciences Overview of Laser Applications Flow Cytometry MPE Imaging Medical Diagnostics Applications: Flow

More information

Think of LASER as a tool

Think of LASER as a tool Mini DPSS Lasers Mini DPSS Lasers Think of LASER as a tool Mini DPSS Mini DPSS Lasers Lasers Versatility. Flexibility. Reliability. The mosquitoo and mosquitoo X series of mini DPSS lasers are designed

More information

Fiber Laser Chirped Pulse Amplifier

Fiber Laser Chirped Pulse Amplifier Fiber Laser Chirped Pulse Amplifier White Paper PN 200-0200-00 Revision 1.2 January 2009 Calmar Laser, Inc www.calmarlaser.com Overview Fiber lasers offer advantages in maintaining stable operation over

More information

Designing for Femtosecond Pulses

Designing for Femtosecond Pulses Designing for Femtosecond Pulses White Paper PN 200-1100-00 Revision 1.1 July 2013 Calmar Laser, Inc www.calmarlaser.com Overview Calmar s femtosecond laser sources are passively mode-locked fiber lasers.

More information

A new picosecond Laser pulse generation method.

A new picosecond Laser pulse generation method. PULSE GATING : A new picosecond Laser pulse generation method. Picosecond lasers can be found in many fields of applications from research to industry. These lasers are very common in bio-photonics, non-linear

More information

pulsecheck The Modular Autocorrelator

pulsecheck The Modular Autocorrelator pulsecheck The Modular Autocorrelator Pulse Measurement Perfection with the Multitalent from APE It is good to have plenty of options at hand. Suitable for the characterization of virtually any ultrafast

More information

Atlantic. Industrial High Power Picosecond Lasers. features

Atlantic. Industrial High Power Picosecond Lasers. features Atlantic Industrial High Picosecond Lasers lasers have been designed as a versatile tool for a variety of industrial material processing applications. They are compact, OEM rugged, with up to 8 W output

More information

Continuous-Wave (CW) Single-Frequency IR Laser. NPRO 125/126 Series

Continuous-Wave (CW) Single-Frequency IR Laser. NPRO 125/126 Series Continuous-Wave (CW) Single-Frequency IR Laser NPRO 125/126 Series www.lumentum.com Data Sheet The Lumentum NPRO 125/126 diode-pumped lasers produce continuous-wave (CW), singlefrequency output at either

More information

Flash-lamp Pumped Q-switched

Flash-lamp Pumped Q-switched NL120 NL200 NL220 NL230 NL300 NL303D NL310 NL300 series electro-optically Q-switched nanosecond Nd:YAG lasers produce high energy pulses with 3 6 ns duration. Pulse repetition rate can be selected in range

More information

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS NL200 NL210 NL230 NL300 NL740 electro-optically Q-switched nanosecond Nd:YAG lasers produce high energy pulses with 3 6 ns duration. Pulse repetition rate can be selected in range of 5 20 Hz. NL30 HT models

More information

Q-SWITCHED LASERS. Engineered Reliability. Rugged Design. No Water. Applications. Features

Q-SWITCHED LASERS. Engineered Reliability. Rugged Design. No Water. Applications. Features Q-SWITCHED LASERS nanio nanio air* air* Industrial DPSS Industrial DPSS Lasers Lasers Engineered Reliability. Rugged Design. No Water. The NANIO AIR lasers are a family of Q-switched DPSS lasers engineered

More information

OBIS CellX. The Universal Light Engine FEATURES

OBIS CellX. The Universal Light Engine FEATURES OBIS CellX The Universal Light Engine OBIS CellX is a multi-wavelength platform for use as the laser excitation Light Engine in applications requiring or laser wavelengths from a single module. CellX delivers

More information

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual 2012 858 West Park Street, Eugene, OR 97401 www.mtinstruments.com Table of Contents Specifications and Overview... 1 General Layout...

More information

Atlantic. Industrial High Power Picosecond Lasers. features

Atlantic. Industrial High Power Picosecond Lasers. features Industrial High Picosecond Lasers lasers have been designed as a versatile tool for a variety of industrial material processing applications. They are compact, OEM rugged, with up to 6 W output power at

More information

Continuous Wave (CW) Single-Frequency IR Laser NPRO 125/126 Series

Continuous Wave (CW) Single-Frequency IR Laser NPRO 125/126 Series COMMERCIAL LASERS Continuous Wave (CW) Single-Frequency IR Laser NPRO 125/126 Series Key Features 1319 or 1064 nm outputs available Fiber-coupled output Proven nonplanar ring oscillator (NPRO) design Superior

More information

improved stability (compared with

improved stability (compared with Picosecond Tunable Systems Nanosecond Lasers NT230 SERIES NT230 series lasers deliver high up to 10 mj energy pulses at 100 Hz pulse repetition rate, tunable over a broad spectral range. Integrated into

More information

Sapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES

Sapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES Sapphire FP Fiber Pigtailed Lasers from Deep Blue to Orange Sapphire FP is a series of true fiber-pigtailed lasers based on Coherent s unique OPSL (Optically Pumped Semiconductor Laser) technology. OPSL

More information

VELA PHOTOINJECTOR LASER. E.W. Snedden, Lasers and Diagnostics Group

VELA PHOTOINJECTOR LASER. E.W. Snedden, Lasers and Diagnostics Group VELA PHOTOINJECTOR LASER E.W. Snedden, Lasers and Diagnostics Group Contents Introduction PI laser step-by-step: Ti:Sapphire oscillator Regenerative amplifier Single-pass amplifier Frequency mixing Emphasis

More information

How to build an Er:fiber femtosecond laser

How to build an Er:fiber femtosecond laser How to build an Er:fiber femtosecond laser Daniele Brida 17.02.2016 Konstanz Ultrafast laser Time domain : pulse train Frequency domain: comb 3 26.03.2016 Frequency comb laser Time domain : pulse train

More information

SNP High Performances IR Microchip Series

SNP High Performances IR Microchip Series SNP High Performances IR Microchip Series Key features Repetition rate up to 130kHz Ultrashort pulses down to 600ps Multi-kW peak power Excellent beam quality, M²

More information

Spider Pulse Characterization

Spider Pulse Characterization Spider Pulse Characterization Spectral and Temporal Characterization of Ultrashort Laser Pulses The Spider series by APE is an all-purpose and frequently used solution for complete characterization of

More information

SNV/U High Performances UV Microchip Series

SNV/U High Performances UV Microchip Series SNV/U High Performances UV Microchip Series Key features 355nm and 266nm Repetition rate up to 20kHz Ultrashort pulses down to 550ps Multi-kW peak power Excellent beam quality Efficient, air-cooled Sealed

More information

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband Continuum White Light Generation WhiteLase: High Power Ultrabroadband Light Sources Technology Ultrafast Pulses + Fiber Laser + Non-linear PCF = Spectral broadening from 400nm to 2500nm Ultrafast Fiber

More information

Atlantic. series. Industrial High Power Picosecond DPSS Lasers

Atlantic. series. Industrial High Power Picosecond DPSS Lasers Atlantic series Industrial High Power Picosecond DPSS Lasers Laser description Laser micromachining is rapidly becoming the material processing technology of choice for numerous small scale, real world

More information

A CW seeded femtosecond optical parametric amplifier

A CW seeded femtosecond optical parametric amplifier Science in China Ser. G Physics, Mechanics & Astronomy 2004 Vol.47 No.6 767 772 767 A CW seeded femtosecond optical parametric amplifier ZHU Heyuan, XU Guang, WANG Tao, QIAN Liejia & FAN Dianyuan State

More information

SNP High Performances IR Microchip Series

SNP High Performances IR Microchip Series SNP High Performances IR Microchip Series KEY FEATURES Repetition rate up to 130 khz Ultrashort pulses down to 600 ps Multi-kW peak power Excellent beam quality, M²

More information

Sapphire LP. CW Visible Lasers from Deep Blue to Orange. Superior Reliability & Performance. Sapphire LP Features:

Sapphire LP. CW Visible Lasers from Deep Blue to Orange. Superior Reliability & Performance. Sapphire LP Features: Sapphire LP Features: Sapphire LP is a series of compact CW visible lasers based on Coherent s unique OPSL (Optically Pumped Semiconductor Laser) technology. OPSL technology not only provides established

More information

ULTRAFAST LASER DIAGNOSTICS

ULTRAFAST LASER DIAGNOSTICS ULTRAFAST LASER DIAGNOSTICS USE OUR APP IN YOUR LAB The faster way to master nonlinear phenomena... Wavelength conversion calculator Bandwidth and pulse duration Frequency conversion Bandwidth conversion

More information

1. INTRODUCTION 2. LASER ABSTRACT

1. INTRODUCTION 2. LASER ABSTRACT Compact solid-state laser to generate 5 mj at 532 nm Bhabana Pati*, James Burgess, Michael Rayno and Kenneth Stebbins Q-Peak, Inc., 135 South Road, Bedford, Massachusetts 01730 ABSTRACT A compact and simple

More information

dnx/dt = -9.3x10-6 / C dny/dt = -13.6x10-6 / C dnz/dt = ( λ)x10-6 / C

dnx/dt = -9.3x10-6 / C dny/dt = -13.6x10-6 / C dnz/dt = ( λ)x10-6 / C Lithium Triborate Crystal LBO Lithium triborate (LiB3O5 or LBO) is an excellent nonlinear optical crystal for many applications. It is grown by an improved flux method. AOTK s LBO is Featured by High damage

More information

Ultrafast instrumentation (No Alignment!)

Ultrafast instrumentation (No Alignment!) Ultrafast instrumentation (No Alignment!) We offer products specialized in ultrafast metrology with strong expertise in the production and characterization of high energy ultrashort pulses. We provide

More information

ignis TECHNICAL DATA SHEET high specification red laser CW 660nm laser Extremely low noise Power 500mW

ignis TECHNICAL DATA SHEET high specification red laser CW 660nm laser Extremely low noise Power 500mW CW 660nm laser Extremely low noise Power 500mW TECHNICAL DATA SHEET The high specification 660nm laser Overview The at 660nm and 500mW is among the most powerful and compact red lasers available today

More information

Single Frequency DPSS Lasers

Single Frequency DPSS Lasers Single Frequency DPSS Lasers Any wavelength from NIR to UV using a single engineering platform based on our proprietary patented BRaMMS DPSS Laser technology. We develop and produce Single Frequency DPSS

More information

Integrated disruptive components for 2µm fibre Lasers ISLA. 2 µm Sub-Picosecond Fiber Lasers

Integrated disruptive components for 2µm fibre Lasers ISLA. 2 µm Sub-Picosecond Fiber Lasers Integrated disruptive components for 2µm fibre Lasers ISLA 2 µm Sub-Picosecond Fiber Lasers Advantages: 2 - microns wavelength offers eye-safety potentially higher pulse energy and average power in single

More information

gem TECHNICAL DATA SHEET CW 532nm laser Extremely low noise Power from 50mW - 750mW 532nm high spec OEM laser

gem TECHNICAL DATA SHEET CW 532nm laser Extremely low noise Power from 50mW - 750mW 532nm high spec OEM laser gem CW 532nm laser Extremely low noise Power from 50mW - 750mW TECHNICAL DATA SHEET gem The high specification CW 532nm laser Overview The gem is the jewel in the Laser Quantum collection. Its small and

More information

Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015

Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015 Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015 Chapter 9: Optical Parametric Amplifiers and Oscillators 9.8 Noncollinear optical parametric amplifier (NOPA) 9.9 Optical parametric chirped-pulse

More information

High-Power, Passively Q-switched Microlaser - Power Amplifier System

High-Power, Passively Q-switched Microlaser - Power Amplifier System High-Power, Passively Q-switched Microlaser - Power Amplifier System Yelena Isyanova Q-Peak, Inc.,135 South Road, Bedford, MA 01730 isyanova@qpeak.com Jeff G. Manni JGM Associates, 6 New England Executive

More information

G. Norris* & G. McConnell

G. Norris* & G. McConnell Relaxed damage threshold intensity conditions and nonlinear increase in the conversion efficiency of an optical parametric oscillator using a bi-directional pump geometry G. Norris* & G. McConnell Centre

More information

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

High Power Supercontinuum Fiber Laser Series. Visible Power [W] Visible Power [W] Crystal Fibre aerolase Koheras SuperK SuperK EXTREME High Power Supercontinuum Fiber Laser Series 400-2400nm white light single mode spectrum Highest visible power Unsurpassed reliability

More information

venteon Ultra-short pulse oscillators

venteon Ultra-short pulse oscillators venteon Ultra-short pulse oscillators Few-cycle femtosecond pulses Stable performance with minimal intervention Measured pulses approaching transform limit Broadest spectral bandwidth commercially available

More information

High Energy Non - Collinear OPA

High Energy Non - Collinear OPA High Energy Non - Collinear OPA Basics of Operation FEATURES Pulse Duration less than 10 fs possible High Energy (> 80 microjoule) Visible Output Wavelength Tuning Computer Controlled Tuning Range 250-375,

More information

Gigashot TM FT High Energy DPSS Laser

Gigashot TM FT High Energy DPSS Laser Gigashot TM FT High Energy DPSS Laser Northrop Grumman Cutting Edge Optronics (636) 916-4900 / Email: st-ceolaser-info@ngc.com 2015 Northrop Grumman Systems Corporation Gigashot TM FT Key Specifications

More information

The extremely compact laser head is approximately 480 mm long and can

The extremely compact laser head is approximately 480 mm long and can Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES Rugged sealed laser cavity Up to 1200 mj pulse energy Better than 1 % StDev pulse energy stability 5 20 Hz pulse repetition rate 3 6 ns pulse

More information

CUBE. Diode Laser System FEATURES

CUBE. Diode Laser System FEATURES CUBE Diode Laser System The Coherent CUBE laser is a compact all-in-one laser system. CUBE lasers offer wavelengths from 75 nm to 70 nm with output power as high as 00 mw. Based on laser diode technologies

More information

Autotracker III. Applications...

Autotracker III. Applications... Autotracker III Harmonic Generation System Model AT-III Applications... Automatic Second Harmonic and Third Harmonic Generation of UV Wavelengths Automatic Production of IR Wavelengths by Difference Frequency

More information

UNMATCHED OUTPUT POWER AND TUNING RANGE

UNMATCHED OUTPUT POWER AND TUNING RANGE ARGOS MODEL 2400 SF SERIES TUNABLE SINGLE-FREQUENCY MID-INFRARED SPECTROSCOPIC SOURCE UNMATCHED OUTPUT POWER AND TUNING RANGE One of Lockheed Martin s innovative laser solutions, Argos TM Model 2400 is

More information

CUBE. Diode Laser System FEATURES & BENEFITS

CUBE. Diode Laser System FEATURES & BENEFITS Diode Laser System The Coherent laser is a compact all-in-one laser system. lasers offer wavelengths from 375 nm to 730 nm with output power as high as 100 mw. Based on laser diode technologies the laser

More information

High Energy Laser Systems

High Energy Laser Systems High Energy Laser Systems 2019 FEMTOSECOND LASERS UltraFlux Tunable Wavelength Femtosecond Laser Systems UltraFlux is a compact high energy tunable wavelength femtosecond laser system which incorporates

More information

ALPHA 5/XS 200 TW Ultrafast Ti:Sa Series

ALPHA 5/XS 200 TW Ultrafast Ti:Sa Series > ALPHA 5/XS 200 TW Ultrafast Ti:Sa Series FEATURES Broadband, high contrast using XPW filter High beam quality with high energy pumping lasers Unmatched energy stability Industrial reliability with water

More information

OBIS CORE LS. Next Generation Miniaturized OEM Laser Module FEATURES

OBIS CORE LS. Next Generation Miniaturized OEM Laser Module FEATURES OBIS CORE LS Next Generation Miniaturized OEM Laser Module The Coherent OBIS CORE LS suite of products provide miniaturized building blocks for OEM instruments designers. Consisting out of the Optically

More information

A Coherent White Paper May 15, 2018

A Coherent White Paper May 15, 2018 OPSL Advantages White Paper #3 Low Noise - No Mode Noise 1. Wavelength flexibility 2. Invariant beam properties 3. No mode noise ( green noise ) 4. Superior reliability - huge installed base The optically

More information

Ultra-stable flashlamp-pumped laser *

Ultra-stable flashlamp-pumped laser * SLAC-PUB-10290 September 2002 Ultra-stable flashlamp-pumped laser * A. Brachmann, J. Clendenin, T.Galetto, T. Maruyama, J.Sodja, J. Turner, M. Woods Stanford Linear Accelerator Center, 2575 Sand Hill Rd.,

More information

Propagation, Dispersion and Measurement of sub-10 fs Pulses

Propagation, Dispersion and Measurement of sub-10 fs Pulses Propagation, Dispersion and Measurement of sub-10 fs Pulses Table of Contents 1. Theory 2. Pulse propagation through various materials o Calculating the index of refraction Glass materials Air Index of

More information

Laser Science and Technology at LLE

Laser Science and Technology at LLE Laser Science and Technology at LLE Nd:glass High energy Electrical Yb:YAG High peak power Mechanical OPCPA High average power Eye injuries OPO Exotic wavelengths Fire J. Bromage Group Leader, Sr. Scientist

More information

PicoBlade 2 Picosecond Micromachining Laser. Precision and flexibility for optimized processes a fully featured, machine-ready system

PicoBlade 2 Picosecond Micromachining Laser. Precision and flexibility for optimized processes a fully featured, machine-ready system PicoBlade 2 Picosecond Micromachining Laser Precision and flexibility for optimized processes a fully featured, machine-ready system www.lumentum.com Data Sheet The PicoBlade 2 laser system is a versatile

More information

FemtoFAB. Femtosecond laser micromachining system. tel fax Konstitucijos ave. 23C LT Vilnius, Lithuania

FemtoFAB. Femtosecond laser micromachining system. tel fax Konstitucijos ave. 23C LT Vilnius, Lithuania FemtoFAB Femtosecond laser micromachining system Konstitucijos ave. 23C LT-08105 Vilnius, Lithuania tel. +370 5 272 57 38 fax +370 5 272 37 04 info@wophotonics.com www.wophotonics.com INTRODUCTION FemtoFAB

More information

Lasers à fibres ns et ps de forte puissance. Francois SALIN EOLITE systems

Lasers à fibres ns et ps de forte puissance. Francois SALIN EOLITE systems Lasers à fibres ns et ps de forte puissance Francois SALIN EOLITE systems Solid-State Laser Concepts rod temperature [K] 347 -- 352 342 -- 347 337 -- 342 333 -- 337 328 -- 333 324 -- 328 319 -- 324 315

More information

Femtosecond to millisecond transient absorption spectroscopy: two lasers one experiment

Femtosecond to millisecond transient absorption spectroscopy: two lasers one experiment 7 Femtosecond to millisecond transient absorption spectroscopy: two lasers one experiment 7.1 INTRODUCTION The essential processes of any solar fuel cell are light absorption, electron hole separation

More information

Lithium Triborate (LiB 3 O 5, LBO)

Lithium Triborate (LiB 3 O 5, LBO) NLO Cr ys tals Introduction Lithium Triborate (LiB 3 O 5, LBO) Lithium Triborate (LiB 3 O 5 or LBO) is an excellent nonlinear optical crystal discovered and developed by FIRSM, CAS (Fujian Institute of

More information

Lithium Triborate (LiB 3 O 5, LBO) Introductions

Lithium Triborate (LiB 3 O 5, LBO) Introductions s Laser s NLO s Birefringent s AO and EO s Lithium Triborate (LiB 3 O 5, ) Introductions Banner Union provide the high quality Broad transparency range from 160nm to 2600nm; High optical homogeneity (δn

More information

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Qiyuan Song (M2) and Aoi Nakamura (B4) Abstracts: We theoretically and experimentally

More information

Dr. Rüdiger Paschotta RP Photonics Consulting GmbH. Competence Area: Fiber Devices

Dr. Rüdiger Paschotta RP Photonics Consulting GmbH. Competence Area: Fiber Devices Dr. Rüdiger Paschotta RP Photonics Consulting GmbH Competence Area: Fiber Devices Topics in this Area Fiber lasers, including exotic types Fiber amplifiers, including telecom-type devices and high power

More information

Solea. Supercontinuum Laser. Applications

Solea. Supercontinuum Laser. Applications Solea Supercontinuum Laser Extended Spectral range: 525 nm - 900 nm (ECO mode), 480 nm - 900 nm (BOOST mode) Extended 2-year worldwide warranty* Supercontinuum output or wavelength selected output through

More information

Coherent Laser Measurement and Control Beam Diagnostics

Coherent Laser Measurement and Control Beam Diagnostics Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination

More information

Fundamental Optics ULTRAFAST THEORY ( ) = ( ) ( q) FUNDAMENTAL OPTICS. q q = ( A150 Ultrafast Theory

Fundamental Optics ULTRAFAST THEORY ( ) = ( ) ( q) FUNDAMENTAL OPTICS. q q = ( A150 Ultrafast Theory ULTRAFAST THEORY The distinguishing aspect of femtosecond laser optics design is the need to control the phase characteristic of the optical system over the requisite wide pulse bandwidth. CVI Laser Optics

More information

5kW DIODE-PUMPED TEST AMPLIFIER

5kW DIODE-PUMPED TEST AMPLIFIER 5kW DIODE-PUMPED TEST AMPLIFIER SUMMARY?Gain - OK, suggest high pump efficiency?efficient extraction - OK, but more accurate data required?self-stabilisation - Yes, to a few % but not well matched to analysis

More information

Case Study: Simplifying Access to High Energy sub-5-fs Pulses

Case Study: Simplifying Access to High Energy sub-5-fs Pulses Case Study: Simplifying Access to High Energy sub-5-fs Pulses High pulse energy and long term stability from a one-box Coherent Astrella ultrafast amplifier, together with a novel hollow fiber compressor

More information

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser Actively Stabilized Scanning Single-Frequency Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser Ring Laser with the following options Broadband Ring Laser Passively Stabilized

More information

LCLS-II-HE Instrumentation

LCLS-II-HE Instrumentation LCLS-II-HE Instrumentation Average Brightness (ph/s/mm 2 /mrad 2 /0.1%BW) LCLS-II-HE: Enabling New Experimental Capabilities Structural Dynamics at the Atomic Scale Expand the photon energy reach of LCLS-II

More information

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION: Theoretical Approach Why do we need ultra short technology?? INTRODUCTION: Generating ultrashort laser pulses that last a few femtoseconds is a highly active area of research that is finding applications

More information

Module 4 : Third order nonlinear optical processes. Lecture 24 : Kerr lens modelocking: An application of self focusing

Module 4 : Third order nonlinear optical processes. Lecture 24 : Kerr lens modelocking: An application of self focusing Module 4 : Third order nonlinear optical processes Lecture 24 : Kerr lens modelocking: An application of self focusing Objectives This lecture deals with the application of self focusing phenomena to ultrafast

More information

Operating longitudinal mode Several Polarization ratio > 100:1. Power. Warranty. 30 <1.5 <5% Near TEM ~4.0 one year

Operating longitudinal mode Several Polarization ratio > 100:1. Power. Warranty. 30 <1.5 <5% Near TEM ~4.0 one year DL CW Blue Violet Laser, 405nm 405 nm Operating longitudinal mode Several Applications: DNA Sequencing Spectrum analysis Optical Instrument Flow Cytometry Interference Measurements Laser lighting show

More information

A 243mJ, Eye-Safe, Injection-Seeded, KTA Ring- Cavity Optical Parametric Oscillator

A 243mJ, Eye-Safe, Injection-Seeded, KTA Ring- Cavity Optical Parametric Oscillator Utah State University DigitalCommons@USU Space Dynamics Lab Publications Space Dynamics Lab 1-1-2011 A 243mJ, Eye-Safe, Injection-Seeded, KTA Ring- Cavity Optical Parametric Oscillator Robert J. Foltynowicz

More information

Tunable Laser. PZT Cavity Tuning

Tunable Laser. PZT Cavity Tuning Coherent Specialty CO 2 Laser Tunable Laser GEM Select 100 Specialty CO 2 Waveguide Laser The GEM Select 100 Advantage The GEM Select 100 Specialty laser brings fieldproven technology for both laboratory

More information

GRENOUILLE.

GRENOUILLE. GRENOUILLE Measuring ultrashort laser pulses the shortest events ever created has always been a challenge. For many years, it was possible to create ultrashort pulses, but not to measure them. Techniques

More information

directly on each side of the crystal to form a rugged, monolithic oscillator that is end pumped by a CW diode laser.

directly on each side of the crystal to form a rugged, monolithic oscillator that is end pumped by a CW diode laser. Product Bulletin MicroChip NanoPulse, NanoGreen, and NanoEyeSafe CDRH Solid-State Lasers The JDS Uniphase MicroChip NanoLaser produces high peak power, high repetition rates, and short pulses from compact,

More information

LRS-0532-PF SERIES INFORMATION SHEET

LRS-0532-PF SERIES INFORMATION SHEET 216-5 ADRIAN AVE. TORONTO, ON, CANADA M6N5G4 T. 1.416.729.7976 F. 1.480.247.4864 SALES@LASERGLOW.COM LRS-0532-PF SERIES INFORMATION SHEET The LRS-0532 Series of Diode-Pumped Solid-State (DPSS) Lasers are

More information

Vertical External Cavity Surface Emitting Laser

Vertical External Cavity Surface Emitting Laser Chapter 4 Optical-pumped Vertical External Cavity Surface Emitting Laser The booming laser techniques named VECSEL combine the flexibility of semiconductor band structure and advantages of solid-state

More information

Testing with Femtosecond Pulses

Testing with Femtosecond Pulses Testing with Femtosecond Pulses White Paper PN 200-0200-00 Revision 1.3 January 2009 Calmar Laser, Inc www.calmarlaser.com Overview Calmar s femtosecond laser sources are passively mode-locked fiber lasers.

More information

Bandpass Edge Dichroic Notch & More

Bandpass Edge Dichroic Notch & More Edmund Optics BROCHURE Filters COPYRIGHT 217 EDMUND OPTICS, INC. ALL RIGHTS RESERVED 1/17 Bandpass Edge Dichroic Notch & More Contact us for a Stock or Custom Quote Today! USA: +1-856-547-3488 EUROPE:

More information

Supercontinuum Sources

Supercontinuum Sources Supercontinuum Sources STYS-SC-5-FC (SM fiber coupled) Supercontinuum source SC-5-FC is a cost effective supercontinuum laser with single mode FC connector output. With a total output power of more than

More information

DCS laser for Thomson scattering diagnostic applications

DCS laser for Thomson scattering diagnostic applications DCS laser for Thomson scattering diagnostic applications Authors Jason Zweiback 10/6/2015 jzweiback@logostech.net 1 Summary Motivation DCS laser Laser for Thomson scattering diagnostics 2 What is the Dynamic

More information