1 Ultra Line DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 3, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable for protection of D.C. feeders with High-Speed DC Breakers, for railway application. The relay measures the Line current and voltage through one current transducer and one voltage transducer. The transducers (type MHCO and MHIT) are galvanically insulated. Via fiber optic and have the following measuring ranges: Line voltage : (0 )Vn Line current : (0 0)In Insulation voltage 0kVac min. Real time measurements of primary input values can be read continuously both from the display and via ports communication. Relay settings can be done via the front and via rear serial communication. Pannel The associated Circuit Breaker can be controlled via the frontal keyboard and via serial communication. Settings, events and oscillographic recordings are stored in a non-volatile memory (E PROM). Besides the normal Watchdog and Powerfail functions, a comprehensive program of self-test and self diagnostic provides: Diagnostic and functional test with checking of programroutines and memory contents, running every time the auxiliary power supply is switched on. Dynamic functional test running during normal operation. Complete Test activated by the keyboard or via the communication bus. Any internal fault detected is indicated by a fault message on the display and by de-energization of associated I.R.F. output relay. The relay is available in three different executions: Flush mounting. Surface mounting. 9 Rack mounting.
2 Protective Functions Thermal image protection of the Cable/Line 4 Overcurrent levels Forward/Reverse programmable Current Step level with di/dt dependance Rate of rise level Impedance monitoring level with di/dt dependance Current monitoring level with di/dt dependence Frame Fault Current and Voltage monitoring levels 4 Shot Automatic Reclosure Overvoltage levels Undervoltage levels Automatic programmable Line Test Energy counter pulse C/B Lock Remote Trip Control Trip circuit supervision Associated Circuit Breaker control (OPEN / CLOSE) Breaker failure protection Breaker interruption energy i t Recording Two complete setting programs switchable locally or remotely Blocking input and Blocking output for pilot wire selectivity coordination and intertripping scheems Event Recording (last 00 events) Trip Recording (last 0 trips) complete with cause of tripping and values of the input quantities at the moment of trip Oscillographic recording of input quantities Communications Modbus RTU, Modbus RTU on TCP-IP and IEC communication protocols RS3 communication port on Front Face RS485 or RJ45 (optional) communication port on Back Panel Synchronisation with other relays (resolution ms) CanBus line for control of slave I/O Expansion modules Technical Characteristics Graphic Display (8x64 dots) 4 LEDS for: Power on/internal relay fault, Trip / alarm, Trip circuit fault 6 Output relays totally user programmable 4 Digital inputs user programmable Mounting Module box, totally draw-out execution IP44 protection case (on request IP54) Totally draw-out execution Power Supply Ratings Type : 4V(-0%) / 0V(+5%) a.c. - 4V(-0%) / 5V(+0%) d.c. Type : 80V(-0%) / 0V(+5%) a.c. - 90V(-0%) / 50V(+0%) d.c. Software MSCom Program interface for device management Accessories High-Voltage Current/Voltage measuring Transducer with Fiber Optic output : Type MHCO-T/V-I High-Voltage Current measuring Transducer with Fiber Optic output : Type MHCO-T-I. High-Voltage Voltage measuring Transducer with Fiber Optic output : Type MHCO-T-V Voltage measuring reciver with fiber optic input and 3 Analogic outputs : Type MHCO-R-V Current measuring reciver with fiber optic input and 3 Analogic outputs : Type MHCO-R-I Input/Output Expansion Module: UX Digital Inputs + 4 Outputs Relay UX4DI - 4 Digital Inputs UX4DO - 4 Outputs Relay Line Test Contactor Line Test Resistor Rail Earthing Contactor Other protection Relay SCADA and Communication systems
3 3 Real Time Measurements I = Current V = Voltage P = Power +Wh, = Exported Energy -Wh, = Imported Energy F49 (T>): Thermal Image element with prealarm Temperature prealarm Continuous admissible current Time constant F - 67/50/5 (I>): st Overcurrent Element F - 67/50/5 (I>): nd Overcurrent Element 3F - 67/50/5 (3I>): 3rd Overcurrent Element 4F - 67/50/5 (4I>): 4th Overcurrent Element F - (DI): st DI Element Minimum di/dt level to start DI : Tal = (0 00)%Tn : Is = (0.5.5) : Kt = ( 600)min step %Tn step 0.0 step 0.0min : Is = (0. 4)In step 0.0In : ts = (0.0 00)s step 0.0s : Is = (0. 4)In step 0.0In : ts = (0.0 00)s step 0.0s : Is = (0. 0)In step 0.0In : ts = (0.0 00)s step 0.0s : Is = (0. 0)In step 0.0In : ts = (0.0 00)s step 0.0s : DI = ( )A step 0A : di = (4 400)A/ms step A/ms : tdi = (0 500)ms step ms Detection reset time delay : tdi = (0 00)ms step ms F - (DI): st DI Element Minimum di/dt level to start DI : DI = ( )A step 0A : di = (4 400)A/ms step A/ms : tdi = (0 500)ms step ms Detection reset time delay : tdi = (0 00)ms step ms
4 4 F - (di/dt): st Current Rate of Rise Element F - (di/dt): nd Current Rate of Rise Element Rapp: Impedance monitoring with di/dt dependence Arc Voltage Internal Resistance Total Resistance of the circuit Internal Inductance Total Inductance of the circuit Resistance trip level Limit value of di/dt Iapp: Current monitoring with di/dt dependence Current trip level when di/dt = 0 Current trip level when di/dt ³ [g] Limit value of di/dt Drop-out percentage : G = (4 400)A/ms : tg = ( 500)ms : G = (4 400)A/ms : tg = ( 500)ms step A/ms step ms step A/ms step ms : Va = (0 800)V : Ri = (0 0.50)W step V step 0.00W : Rt = (0.00.5)W step 0.00W : Li = ( )H step 0.00H : Li = ( )H step 0.00H : R* = (0 00)W step 0.0W : g = (0 500)A/ms step A/ms : g = (0 00)ms step ms : Ia = ( )A step 0A : I* = ( )A step 0A : g = (30 500)A/ms step A/ms : Res = (80 00)%Iapp step %Iapp : tr = (0 5)s step 0.0s F - 64 (Ig): st Frame Fault Element Current setting range : Is = (0. 4)Ign step 0.0Ign Voltage setting range : Us = (0.0 )Ugn step 0.0Ugn : ts = (0.0 00)s step 0.0s F - 64 (Ig): nd Frame Fault Element Current setting range : Is = (0. 4)Ign step 0.0Ign Voltage setting range : Us = (0.0 )Ugn step 0.0Ugn : ts = (0.0 00)s step 0.0s
5 5 RCL: Automatic Reclosure Number of Reclosure Reclaim time : ShN = / / 3 / 4 : tr = ( 00)s step s Time first reclosure : t = (0. 000)s step 0.s Time second reclosure : t = (0. 000)s step 0.s Time third reclosure : t3 = (0. 000)s step 0.s Time fourth reclosure : t4 = (0. 000)s step 0.s LT: Automatic Line Test (Double Voltage Line test) Number of Test Minimum residual voltage downstream : TestN = 0 / / 3 / 4 : Vv< = (0 )Vn step 0.00Vn Minimum residual voltage upstream : Vm< = (0 )Vn step 0.00Vn Minimum residual resistance : RR< = (0 500)W step W Minimum line voltage : VFast = (0.5 )Vn step 0.Vn Waiting time after C/B closing : tp = (0 30)s step s Duation of the Line Test : tt = ( 0)s step s Wait time between consecutive tests : tcy = ( 60)s step s Wait time to start recl.after succes fine test : tw = (0 0)s step s F - 59 (U>): st Overvoltage Element : Us = (0.5.5)Un step 0.0Un : ts = (0 650)s step s F - 59 (U>): nd Overvoltage Element : Us = (0.5.5)Un step 0.0Un : ts = (0 650)s step s F - 7 (U<): st Undervoltage Element : Us = (0. )Un step 0.0Un : ts = (0 650)s step s F - 7 (U<): nd Undervoltage Element : Us = (0. )Un step 0.0Un : ts = (0 650)s step s Wi: Circuit Breaker Energy Maintenence : Ii = (0. 99)In step 0.In Conventional interrupption current : Wi = ( 9999) step RT: Remote Trip : ts = (0 0)s step 0.0s Wh: Energy Counter Pulse Energy level : WpP = (0 000)kW step 0kW Pulse duration : Pulse = (0. )s step 0.0s CB-L: C/B Lock Breaker Failure Element Alarm time delay : tbf = ( )s step 0.0s
6 6 (Example with MHCO Transducer) R PL + - LINEE LINEA FRAME-TO-GROUND VOLTAGE MONITORING INPUT FRAME-TO-GROUND CURRENT MHCO-TV MHCO-TVI MONITORING INPUT MHCO-RV MHCO-R-I MHCO-R-V 3 4 (4) (4) (8) (9) POWER SUPPLY ALIM. AUSILIARA. OPTION OPTION In 0In _ MS-SCE387-R0 = ULTRA D.C. Feeder Manager Relay POWER TRIP ON OFF BPU R R R3 R4 R5 FRONT - RS3 R6 RS485 CAN R R R3 R4 R5 R6 D D D3 D4 ETHERNET A(S+) B(S-) C C H L RJ N.O. 34 N.C TRIP COIL SUP. (5) OUTPUT RELAY RELE' DI USCITA DIGITAL INPUTS INGRESSI DIGITALI RS485 AI MODULI AGGIUNTIVI TO EXPANSION MODULE RJ45 (ModbusOnTCP) RJ45 (Serial on Ethernet) RJ45 (IEC6850) RS485 (Modbus RTU) Typical Characteristics Accuracy at reference value of influencing factors Input Averange power supply consumption Output relays % FS for measurements % +/- 0ms for times 0 0 ma < 0 VA rating 5A; Vn = 380V A.C. resistive switching = 00W (380V max) make = 30A (peak) 0.5 sec. break = 0.3A, 0Vcc L/R = 40ms ( op.) Order code - Example : Power Supply Configuration R (4-5) = Type = N.O. = Type = N.C. st Expansion module = None = UX0-4 3 = 4DI 4 = 4DO nd Expansion module = None = UX0-4 3 = 4DI 4 = 4DO Communication Protocol = ModbusRTU (standard) = Modbus TCP-IP 3 = IEC6850 The performance and the charecteristics reported in this document are not binding and can modified ant any moment without notice. Microelettrica Scientifica S.p.A Buccinasco (MI) - Via Lucania, Italy Tel Fax sales.relays@microelettrica.com
Protection Relays. U-MLEs-PLv-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80
Ultra-Ts DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable
More informationProtection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80
Ultra-Ts DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable
More informationFMR. Ultra Line FEEDER MANAGER RELAY
Ultra Line FEEDER MANAGER RELAY Protective Functions F49 : One Thermal Image element F50/51/67 : Three levels for phase overcurrent independentely programmable as directional or non directional F50N/51N/67N
More informationMHCO MHCO-RI. General Characteristics The transducer MHCO provide a measurement of current or voltage fully isolated and safe.
-TVI -RI -RV D.C. MEASURING CONVERTER Converter for D.C. Current and/or Voltage measurement. Direct connection to D.C. mains rating up to 4 kvcc. Fully isolated multi-voltage power suppy. Fiber optic connection
More informationFault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice
Issued: April 1999 Status: Updated Version: B/08.11.200 Data subject to change without notice Features Versatile, multifunction line fault indicator for distribution networks Overcurrent, earth-fault and
More informationREF 610 Feeder Protection Relay. Technical Reference Manual
REF 610 1MRS 755310 Issued: 05.10.2004 Version: A/05.10.2004 REF 610 Contents 1. Introduction...6 1.1. About this manual...6 1.2. The use of the relay...6 1.3. Features...6 1.4. Guarantee...8 2. Safety
More informationBUS2000 Busbar Differential Protection System
BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection 1 Typical Busbar Arrangements Single Busbar Double Busbar with Coupler Breaker and a Half
More informationNTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide
NTG MULTIFUNCTON GENERATOR PROTECTION RELAY 1 NTG Digital protection relay that integrates a number of functions required r for the protection of generators. It is used in power stations from gas, steam,
More informationHigh-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime
Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with
More informationStabilized Differential Relay SPAD 346. Product Guide
Issued: July 1998 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault
More informationRETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).
RETROFITTING Motor Protection Relay NPM800R (R2 case) and NPM800RE (R3 case) are dedicated to the refurbishment of 7000 series (R2 and R3 cases) of CEE relays providing the protection of medium voltage
More informationPD300. Transformer, generator and motor protection Data sheet
PD300 Transformer, generator and motor protection Data sheet DSE_PD300_eng_AO No part of this publication may be reproduced by whatever means without the prior written permission of Ingeteam T&D. One of
More informationFMR-TR (Multiple I/O Boards) ULTRA Line
FEEDER MANAGER with AUTORECLOSING RELAY TYPE FMR-TR (Multiple I/O Boards) ULTRA Line OPERATION MANUAL Copyright 2006 Data 21.03.2007 Rev. 2 Pag. 1 of 90 INDEX 1. GENERAL UTILIZATION AND COMMISSIONING DIRECTIONS
More informationINSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W
Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING
More informationSPAD 346 C Stabilized differential relay
SPAD 346 C Stabilized differential relay Stabilized Differential Relay Type SPAD 346 C Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault
More informationsw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS
INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS
More informationBU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS
INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported
More informationMultimeter 500CVD21 RTU500 series
Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase
More informationMT 560/UMT TRANSDUCER & ANALYZER
MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.
More informationProtection relays and transformers
NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Protection
More informationAC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)
AC CURRENT GENERATOR PERFORMANCES Wide range of current 50 db dynamic range Signal-to-noise ratio: 80 db open loop protection Stability < 0,1% Very low THD distortion < 0,3% External synchronization Build-up
More informationSPAA 341 C. Feeder Protection Relay. User s manual and Technical description SPAA 341 C. U aux V ~ V. f n. t 2 > [ s ] 0 I 0 >> Trip
SPAA C Feeder Protection Relay User s manual and Technical description f n = 0Hz 0Hz I n = A A ( I ) I n = A A ( I 0B ) I n = 0,A A ( I 0 ) U n = 00V 0V 0V ( ) U 0 I > I I L I L I L I o IRF Uo I o ϕ U
More informationNPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.
REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationModular range of digital protection relays
S e p a m s e r i e s 2 0, 4 0, 8 0 Modular range of digital protection relays Fast Dependable Simple Fast response Maximum dependability Your electrical equipment is under control. With Sepam protection
More informationNPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator
REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds
More informationN100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.
cat iii Electrical Safety N100 - power network analyzer Measurement of power network parameters in 3 or 4-wire, balanced or unbalanced systems. two-color led display (red, green). Four quadrant energy
More informationnew! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS
new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320
More informationSingle Channel Loop Detector
Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More informationData Acquisition Modules/ Distributed IO Modules
User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332
More informationM.3. Electrical measurement and control. Electrical energy meters for partial consumption
M.3 Electrical measurement and control Electrical energy meters for partial consumption M.3 Electrical energy meters for partial consumption M.3 - Electrical energy meters for partial consumption Introduction
More informationMonitoring Electric Network Via Internet
Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording
More informationnd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485
cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase
More informationPower quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I
Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)
More informationAddendum Operation Manual IM30-DREK MICROPROCESSOR OVERCURRENT AND DIRECTIONAL EARTH FAULT PROTECTION RELAY + AUTORECLOSE TYPE IM30-DREK ADDENDUM
K Pag. 1 of 6 MICROPROCESSOR OVERCURRENT AND DIRECTIONAL EARTH FAULT PROTECTION RELAY + AUTORECLOSE TYPE K ADDENDUM OPERATION MANUAL I> I>> O> O>> MICROELETTRICA MILANO SCIENTIFICA ITALY PROG/ I.R.F. I2>
More information- Protective & control functions
NA21 FEEDER PROTECTION RELAY THE BASIC SOLUTION FOR FEEDERS AND TRANSFORMERS PROTECTION WITH THERMAL IMAGE, NEGATIVE SEQUENCE OVERCURRENT AND AUTOMATIC RECLOSURE Application The relay type NA21 is typically
More informationNETWORK ANALYZERS Analyzers
CONTENTS PRODUCTS RANGE NA.03 NETWORK ANALYZER - LCC NETWORK ANALYZER - LCA NETWORK ANALYZER - LDA NETWORK ANALYZER - LAB96 NETWORK ANALYZER - LABM NA.04 NA.06 NA.09 NA.10 NA.13 NETWORK ANALYZER - LCCM
More informationPhase and neutral overcurrent protection
Phase and neutral overcurrent protection Page 1 ssued June 1999 Changed since July 1998 Data subject to change without notice (SE970165) Features Two-phase or three-phase time-overcurrent and earth fault
More informationATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationData sheet CPU 013C (013-CCF0R00)
Data sheet CPU 013C (013-CCF0R00) Technical data Order no. 013-CCF0R00 Type CPU 013C Module ID - General information Note - Features SPEED7 technology 16 x DI, 12 x DO, 2 x AI, from which are 4 input channels
More information(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144
Panel Meters, Accessories Moving Coil, DQ Moving Coil, VDQ Moving Iron, EQ (240 ) (90 ) Measurement of DC currents and DC voltages. Measurement of AC currents and AC voltages. Measurement of AC currents
More informationA proven distribution feeder solution with integrated protection, monitoring, and control
SEL-35 Protection System A proven distribution feeder solution with integrated protection, monitoring, and control Achieve sensitive and secure fault detection using comprehensive protection functions.
More informationT/3000 T/3000. Substation Maintenance and Commissioning Test Equipment
T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY
More information7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy
Reyrolle Protection Devices 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Description Additional Options Solkor
More informationFixed Series Compensation
Fixed Series Compensation High-reliable turnkey services for fixed series compensation NR Electric Corporation The Fixed Series Compensation (FSC) solution is composed of NR's PCS-9570 FSC control and
More informationData sheet VIPA CPU 314SC DPM (314-6CG23)
Data sheet VIPA CPU 314SC DPM (314-6CG23) Technical data Order no. Type 314-6CG23 VIPA CPU 314SC DPM General information Note - Features Powered by SPEED7 Work memory [KB]: 512...2.048 Onboard 24x DI /
More informationATV12H018F1 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component
More informationDRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application
More information90 ReStart AUTOMATIC RECLOSING DEVICES
RESTART WITH AUTOTEST Technical data TYPE ReStart with Autotest 2P ReStart with Autotest PRO 2P ReStart with Autotest PRO 4P Electrical characteristics Standards: EN 50557, EN 61008-1 Distribution system:
More informationSPAC 335 C and SPAC 336 C Feeder terminals
SPAC 335 C and SPAC 336 C Feeder terminals User s manual and Technical description I n = / 5 A( I ) I n = / 5 A( I o ) f n = 50 60 Hz SPAC 335 C U n = 00 / 0 V( U o ) 5 IRF O I B I > I I L I L3 Uo I o
More informationIndustrial Modbus I/O Modules
Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction
More informationEE Lecture 14 Wed Feb 8, 2017
EE 5223 - Lecture 14 Wed Feb 8, 2017 Ongoing List of Topics: URL: http://www.ece.mtu.edu/faculty/bamork/ee5223/index.htm Labs - EE5224 Lab 3 - begins on Tues Feb 14th Term Project - details posted. Limit
More informationDimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung
Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationSPAA 120 C and SPAA 121 C Feeder protection relay
SPAA 10 C and SPAA 11 C Feeder protection relay User s manual and Technical description f n = 50Hz 60Hz I n = 1A 5A ( I ) I n = 1A 5A ( I o ) U n = 100V 110V ( U o ) 5 B I > I I L1 I L3 Uo I o IRF SPAA
More information200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features
CT ratio Power Harmonics ac+dc 200ADM-P Current Injection System with Phase Shift Features 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary AC voltage/current output with
More informationSPAJ 111 C. Sensitive earth-fault relay SPAJ 111 C. User s manual and Technical description. U aux V ~ V. f n. n ( I o>> SPCJ 1C7
SPAJ 111 C Sensitive earth-fault relay User s manual and Technical description I n = 1A 5A ( I ) f n = 50Hz 60Hz 2 5 B I o I IRF SPAJ 111 C 80...265V ~ 18...80V U aux STEP I o > [%] I n 1.0 6.0 10 STEP
More informationPLA 33. Power line analyzer. User and service manual. version 2.4
PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationIM30-DRE MICROPROCESSOR OVERCURRENT AND DIRECTIONAL EARTH FAULT PROTECTION RELAY + AUTORECLOSE TYPE IM30-DRE OPERATION MANUAL
Pag. 1 of 34 MICROPROCESSOR OVERCURRENT AND DIRECTIONAL EARTH FAULT PROTECTION RELAY + AUTORECLOSE TYPE IM30-DRE OPERATION MANUAL Pag. 2 of 34 INDEX 1 General utilization and commissioning directions 3
More informationMeasuring transducers
Measuring transducers MT4xx and (U)MT5xx Measuring transducer MT440 MT 440 Programmable multifunctional transducer Real time measurements of more than 50 quantities Power accuracy class 0.5 16 adjustable
More informationHarmonic restraint earth fault or single-phase overcurrent protection
Harmonic restraint earth fault or single-phase overcurrent protection Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970885) Features Sensitive earth fault protection
More informationSide view View from below Rear view
Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4
More informationUMG 509-PRO. Multifunction power analyser with RCM
UMG 509-PRO Multifunction power analyser with RCM Power quality RCM Residual current monitoring Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management Communication Profibus (DP/V0)
More informationMICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2
PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features
More informationnd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS
nd30pnet tri Measurement of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems. graphical color display:
More informationDUCATI INSTRUMENTS COMPARISON TABLE
DUCATI INSTRUMENTS COMPARISON TABLE DUCA47 DUCA47-7 DUCA47-7-SP -96 P P 6 module DIN rail mounting instrument 7x7 panel mounting instrument 96x96 panel mounting instrument Low internal depth High-contrast
More informationpresentation contents application advantages
presentation contents page presentation protection functional and connection schemes other connection schemes connection characteristics 9 installation 0 commissioning ordering information Sepam 00 is
More informationXR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)
XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by
More informationISO 9001:2000 SIA C. Dual Power Overcurrent Protection Relay INSTALLATION GUIDE. Guia_SIA-C_Rev / 32
ISO 9001:2000 SIA Dual Power Overcurrent Protection Relay INSTALLATION GUIDE www.fanox.com Guia_SIA-_Rev. 01 1 / 32 1.USER INTERFAE... 4 1.1. Revision A... 4 1.2. Revision B and... 4 1.3. Bistable magnetic
More informationEnergy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming
Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationData sheet CPU 314ST/DPM (314-6CF02)
Data sheet CPU 314ST/DPM (314-6CF02) Technical data Order no. Type 314-6CF02 CPU 314ST/DPM General information Note - Features SPEED-Bus SPEED7 technology, SPEED-Bus 8 x DI, 8 x DIO, 4 x AI, 2 x AO, 1
More informationXIOC technology and networking modules
/ XIO XIO digitale and analog input/output modules XIO technology and networking modules XIO the compact I/O and much more XIO are local expansion modules for direct connection to all Xontrol controllers.
More informationSPAS 348 C. Feeder Protection Relay. User s manual and Technical description SPAS 348 C V ~ V. t 2 > [ s ] f n = 50Hz 60Hz
SPAS 8 C Feeder Protection Relay User s manual and Technical description f n = 50Hz 60Hz I n = A 5A ( I ) I n = 0,A A ( I 0 ) U n 00V...0V ( U ) U n = 00V/0V/0V ( U 0 ) 5 I > I L U I L U IRF B I > I L
More informationNumbering System for Protective Devices, Control and Indication Devices for Power Systems
Appendix C Numbering System for Protective Devices, Control and Indication Devices for Power Systems C.1 APPLICATION OF PROTECTIVE RELAYS, CONTROL AND ALARM DEVICES FOR POWER SYSTEM CIRCUITS The requirements
More informationMULTIFUNCTION GRAPHICAL UNIT MGU 800
MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible
More informationComplex Solution for the Distribution Substation REF 542plus. Application and Setting Guide
Complex Solution for the Distribution Substation REF 542plus 1MRS756412 Complex Solution for the Distribution Substation REF 542plus Copyrights The information in this document is subject to change without
More informationPROMUX Distributed MODBUS I/O Modules Catalog and Design Guide
PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 14/11/2006 V10 P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com
More informationSPAJ 110 C. Earth-fault relay SPAJ 110 C. User s manual and Technical description. U aux V ~ V f n. n ( I o>> SPCJ 1C8
SPAJ 110 C Earth-fault relay User s manual and Technical description I n = 1A 5A ( I ) f n = 50Hz 60Hz 2 5 B I o I IRF SPAJ 110 C 80...265V ~ 18...80V U aux STEP I o > I n 0.1 0.35 0.8 STEP SPCJ 1C8 REGISTERS
More informationDIN rail mounting temperature controller with current transformer input deltadue series D1 line
BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting
More informationCompany Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D
Document type Page Verksamhetsstyrande 1 (11) Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D17-0008990 1.0 Organisation Valid from Valid until Regionnätsaffärer
More informationSPAS 120 C Directional earth-fault relay
SPAS 120 C Directional earth-fault relay User s manual and Technical description B I 2 f n = 0Hz 60Hz I n = 1A A ( I o ) U n = 100V 110V ( U o ) U o I o I ϕ IRF SPAS 120 C 80...26V ~ 18...80V U aux I ϕ
More informationZHUHAI PILOT TECHNOLOGY CO., LTD.
SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.
More informationData sheet CPU 313SC (313-5BF13)
Data sheet CPU 313SC (313-5BF13) Technical data Order no. Type 313-5BF13 CPU 313SC General information Note - Features SPEED-Bus - SPEED7 technology 24 x DI, 16 x DO, 4 x AI, 2 x AO, 1 x AI Pt100 128 kb
More informationDPX³ 250 Electronic 4P - ModbusTable LGR EN v1.01.xls
GENERAL MODBUS TABLE ORGANIZATION Starting of the Group s Starting of the Group s System Version (Release) System Version (Build) Group Name (Text) Group Code Group Complexity Group Version 1638 000 01
More informationASHIDA Numerical 3OC + 1EF Protection Relay
PROTH. ERR L5 PKP FAULT DT REC LOCK BF L6 L7 CLOSE TRIP ADR 241B Protection Features : 4 Element (3 Phase + EF + Sensitive EF) Over current IDMT/DMT with instant trip. Programmable (Non- Volatile) Setting
More informationES-777-MV-P2_A1 03/01/10
ENGINEERING SPECIFICATION SYMCOM MODEL 777-MV-P2 Electronic Overload Relay PART 1 GENERAL 1.1 REFERENCES A. UL 508 Industrial Control Equipment Underwriters Laboratories B. IEC 60947 Low Voltage Switchgear
More informationZ-10-D-IN. RS485 Modbus Module 10 Digital Inputs
S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -
More informationNO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.
MODBUS/BECO2200-M3425A Communication Data Base for M-3425A Integrated Protection System Device I.D. = 150 Specifications presented herein are thought to be accurate at the time of publication but are subject
More information1S24. Arc Fault Monitoring System. Arc fault protection to provide high speed detection and clearance of arcing faults.
P R O T E C T I O N O F A I R I N S U L A T E D M E T A L C L A D S W I T C H G E A R Arc Fault Monitoring System Arc fault protection to provide high speed detection and clearance of arcing faults. >
More informationa * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD
3x 0/4...20 ma 8x nd40 ṉ - power network analyzer / recorder Measurement and recording of over 500 electric energy quality parameters acc. to en 50160, en 61000-4-30, en 61000-4-7 standards. Measuring
More informationDMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202
DMTME-96 2CSG133030R4022 M204675 DMTME-I-485-96 2CSG163030R4022 M204685 2CSG445001D0202 GB Operation and assembly instructions DMTME-96: three-phase multimeter for panel mounting, used also in singlephase
More informationEnergy Management Energy Meter Type EM340
Energy Management Energy Meter Type EM340 Digital input (for tariff management Easy connection or wrong current direction detection Certified according to MID Directive (option PF only: see how to order
More informationTemperature Controller
Temperature Controller 1/8 IN - 48 x 96mm Platinum Series X400 Line Cost Effective Solutions This 48x96mm size controller of the Platinum Series, provides a high degree of functionality and reliability
More informationXUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)
XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationNetworks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM
Power quality Colour graphical display Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management UMG 508 Multifunction power analyser Communication Profibus (DP/V0) Modbus (RTU,
More informationXR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)
XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided
More information