1 Datasheet Grid eeding monitoring relay according to CEI 0-21 CM-UFD.M32 CM-UFD.M32 is a multiunctional grid eeding monitoring relay. It provides dierent monitoring unctions in accordance with CEI 0-21 ed. June It detects over- and undervoltage (10 minutes average value, voltage increase and decrease protection) as well as any changes in grid requency (double thresholds, requency increase and decrease protection). The device is connected between the decentralized electrical energy source and the public grid in order to disconnect it, in case o problems, aults or maintenance into the grid. Characteristics - Monitoring o single and three-phase mains or grid eeding - Type-tested in accordance with CEI Over- and undervoltage, 10 minutes average value as well as over- and underrequency monitoring - Two-tier threshold settings or over-/ undervoltage/ -requency - Integrated management o redundancy unction (mandatory in plants with P>20 kw) - Measured values, thresholds and settings shown on the display - All threshold values adjustable as absolute values - Deault setting according to CEI True RMS measuring principle - High measurement accuracy - 3 input contacts or remote trip, eedback signal, and external signal - Tripping delay or each threshold adjustable - Alarm memory or up to 10 entries (incl. cause o alarm, measured value, relative timestamp) - Autotest unction - Password setting protection - 3 c/o (SPDT) contacts mm, 6 modules case or DIN rail - LEDs or the indication o operational states. Marks Order data Type Rated control supply voltage Measuring range Order code CM-UFD.M32 24 V AC/DC or 230 V AC V AC 1SVR R4400

2 Grid eeding monitoring relay according to CEI 0-21 Programming mode and use Functions Operating controls A1 A2 A3 A4 Y20 Y21 L1 L2 L3 N Y30 Y31 220V AC 24V AC/DC Y10 Y11 Application The grid eeding monitoring relay (SPI), that monitors network voltage and requency, allows to disconnect distributed generation (GD) whenever the parameters are over the adjusted thresholds. Completely adjustable the CM-UFD.M32 assures the necessary lexibility to integrate medium and small production plants. In conormity to CEI 0-21 Ed. June 2012, the CM-UFD.M32 relay could be used in all the low voltage plants and in medium voltage plants with power less than 30 kw. The relay is mandatory in all low voltage production plants with power > 6 kw or with more than 3 generators (eg. Plants with more than 3 inverters). Operating principle CM-UFD U F1 F2 Display programming/exit Values increase LEDs status Values decrease Conirm selection Protective unctions I control supply voltage is applied and all phases are present with correct voltage and requency values, output relay 11-12/14 (DDI) energizes and the start-up delay begins. When the delay is complete, output relay 21-22/24 energizes or de-energizes, depending on the coniguration. The green LED U is on. I the measured values exceed or all below the set threshold values, output relay 11-12/14 de-energizes ater the adjusted delay and output relay 21-22/24 energizes or de-energizes, depending on the coniguration, when the adjusted delay is complete. The ault type is indicated by the red LEDs F1 or F2. The threshold value that has caused tripping is shown on the display. As soon as the measured value returns to the tolerance range, taking into account a ixed hysteresis (less than 100 ms as requested by standard CEI 0-21), output relay 11-12/14 re-energizes without delay; output relay 21-22/24 energizes or de-energizes, depending on the coniguration, when the adjusted delay is complete. When output relay 11-12/14 is re-energized the red LEDs F1 or F2 turn o and the ault message on the display disappears. The event that has caused tripping o the relay is recorded in the menu events. Protective unction V>59 S1 med. (10-minutes average value): The relay calculates the sliding root mean square o the voltage value (in case o 3 phase 3 voltage values) over a period o 10 minutes. The voltage values are updated every 3 seconds. I the 10-minutes average value exceeds the threshold value, the output relays trip when the adjusted delay is complete. Remote trip Measurements Trip DDI External signal Local command 2 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

3 Event list The relay records and logs the last 10 events that caused tripping o the relay. Relevant inormation is available in the menu Events where the type o event such as protection or auto test are recorded as well as the time passed since the last tripping o the relay in hours, minutes and seconds. I the relay is switched-o and switched-on again, the measured time is reset. Redundancy unction The redundancy relay 31/32-34 (DG) is activated i relay 11/12-14 has de-energized and, within the adjustable time delay, no eedback rom the external contact has been recognized by the internal logic via Y10-Y11. The external contact is connected in series to the coil o the relay itsel, representing the status o the disconnection device. In case a eedback signal is present, the redundancy relay does not trip. Relay 2 (21/22-24) Output relay 2 can be used or the closing command o the breaker motor. In case output relay 11/12-14 energizes the adjustable delay T1 starts. When T1 is complete, output relay 21/22-24 will be activated or the duration o the pulse time T2 or until relay 11/12-14 de-energizes. In this last case T2 is inactive (T2= LOCK). The operating principle o the relay 21/22-24 is conigurable as normally energized (closed-circuit principle) or normally de-energized (open-circuit principle). Local command and external signal The CEI-021 standard deines Restrictive thresholds, the under- and overrequency thresholds S1 ( Hz), and Permissive thresholds, the under- and overrequency thresholds S2 ( Hz). Selection o S1 or S2 thresholds is made by the corresponding combination o the external signal and the local command, as shown in this table: External Signal Local Command Frequency Range 0 0 Permissive S2 1 0 Permissive S2 0 1 Permissive S2 1 1 Restrictive S1 Note: In order to activate restrictive thresholds S1 also input Y30-Y31 has to be closed. Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

4 Grid eeding monitoring relay according to CEI 0-21 Programming mode and use Remote trip The control input Y20-Y21 can be conigured as normally open or normally closed. I normally closed is conigured, the grid eeding monitoring relay trips i Y20-Y21 is opened. I normally open is conigured, the relay trips i Y20-Y21 is closed. Within less than 50 ms ater activation o the remote trip input, output relay 11/12-14 de-energizes, and output relay 21/22-24 energizes or de-energizes, depending on the coniguration. When the remote trip input is deactivated the output relays 11/12-14 and 21/22-24 trip again. Autotest The auto test unction allows the veriication o the protective unctions operability. Selection o the unction to be tested starts the auto test. The display shows the threshold value that increases or decreases until the input voltage or requency value that causes tripping o the output relays is reached. I during the sweep any value o the unction setting range meets the same value o the input quantity supplied to the relay (Voltage or Frequency), the unction under test trips, operates the output relay and the display shows OK : the Autotest has veriied that the relay trips correctly. I during the sweep no value o the unction setting range meets the same value o the input quantity supplied to the relay (Voltage or Frequency), the unction under test does not trip and the display shows KO : the Autotest has veriied that the relay does not trip untimely. This is the case when the value o the input quantity supplied to the relay is the nominal one which, o course, is outside the unctions setting range. To have the unction tripping during the Autotest, the input quantity must be arranged to a value within the unction setting range. The result is stored in the event list. Electrical connection A1 A2 A3 A4 Y20 Y21 L1 L2 L3 N Y30 Y31 220V AC Connection A1-A2 A3-A4 L1,L2,L3,N 24V AC/DC Y10-Y11 Input 1 Y20-Y21 Digital Input 2 Y30-Y31 Digital Input 3 Y10 Y11 Note: only one auxiliary power supply is allowed Output relays scheme CM-UFD U F1 F2 control supply voltage 230 V AC control supply voltage 24 V AC/DC measuring inputs DDI eedback remote trip or DDI external signal 11-12/14 Output Relay 1 trip relay (normally energized) 21-22/24 Output Relay 2 (2 nd DDI or closing command or breaker motor) conigurable (normally energized or de-energized) 31-32/34 Output Relay 3 redundancy relay or DG. Conigurable (normally energized or de-energized) CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

5 Coniguration The relay is delivered with deault settings in accordance to CEI 0-21 table 8. Thanks to the wide display and to appropriate buttons it s possible to set all the relay parameters in a very simple way. The menu structure starts with the main page that shows the real time measured values. Passing through diagnostic and test pages, it s possible to view the protection unctions parameters pages. The main page that shows the real time measured values: - press button SET to enter in the menu - press arrow buttons to move between unctions and parameters - press button ENTER to enter in the chosen page - using arrow buttons it s possible to modiy the values o the parameters - press ENTER button to conirm the value and proceed into the menu - press SET button to return to, till the main page Visualization o the parameter is always possible, modiication only ater having entered the password. V 230 V Password Min V 27 S1 V V 230 V 231 V I/O managem. 195 V F Hz Events rec. Time 400 ms Warning: any CM-UFD.M32 relay is delivered with the same deault password. The installer is responsible or the veriication o the parameter values and the change o the password with a personal one in order to avoid unwanted modiications. Deault settings table Protective unctions Threshold Tripping delay 1 st Overvoltage med. (59 S1) 253 V 3 sec 2 nd Overvoltage (59 S2) 265 V 0.2 sec 1 st Undervoltage (27 S1) 196 V 0.4 sec 2 nd Undervoltage (27 S2) 92 V 0.2 sec 1 st Overrequency (81> S1) 50.5 Hz 0.1 sec 1 st Underrequency (81< S1) 49.5 Hz 0.1 sec 2 nd Overrequency (81> S2) 51.5 Hz 0.1 sec 2 nd Underrequency (81< S2) 47.5 Hz 0.1 sec Note: the voltage settings are always reerred to phase-neutral (Vn 230 V). In order to bring back values to phase-phase (Vn 400 V) or viceversa use the 1,732 constant. Indication o operational states LEDs, status inormation LEDs status U green LED ON: ALL 3 LEDs lashing: F1 LED lashing: F1 LED ON: F2 LED lashing: F2 LED ON: Cause normal working condition device malunctioning prewarning under-/overvoltage inal switch-o under-/overvoltage prewarning under-/overrequency inal switch-o under-/overrequency Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

6 Grid eeding monitoring relay according to CEI 0-21 Menu structure Main menu Measurements Password Autotest Events rec. I/O Managem. Connection Options Language 6 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

7 Password management Password Autotest Events Recording Password 0 the correct password (0-9999) by means o the buttons Up/Down. Press button SET to conirm. Now, programming can start (the authorization is displayed by the asterisk shown at the ar right bottom o the display). Press button ENTER to go to the menu PASSWORD or changing the password Measurements Password Modiication 0 the new password (0-9999) by means o the buttons Up/Down Conirm Password 0 Measurements Misure Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

8 Grid eeding monitoring relay according to CEI 0-21 Menu structure Protective unctions parameters setting Password Autotest Events Recording Min V 27 S1 196 Time 400 First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the threshold value and the tripping delay can be adjusted within the ollowing ranges: Threshold: (46-230)V step 1 V Delay: ( )ms step 10 ms Measurements Misure Min V 27 S2 Measurements Misure Time Threshold: (12-230)V step 1 V Delay: ( )ms step 10 ms Vmed. 59 S1 Measurements Misure Time Threshold: ( )V step 1 V Delay: ( )ms step 50 ms Max V 59 S2 Measurements Misure Time Threshold: ( )V step 1 V Delay ( )ms step 10 ms 8 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

9 Min F 81 S1 Measurements Misure Time 49,5 100 Threshold: (47-50)Hz step 0,1 Hz Delay: ( )ms step 10 ms Min F 81 S2 Measurements Misure Time 47,5 100 Threshold: (47-50)Hz step 0,1 Hz Delay: ( )ms step 10 ms Max F 81 S1 Measurements Misure Time 50,5 100 Threshold: (50-52)Hz step 0,1 Hz Delay: ( )ms step 10 ms Max F 81 S2 Measurements Misure Time 51,5 100 Threshold: (50-52)Hz step 0,1 Hz Delay: ( )ms step 10 ms Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

10 Grid eeding monitoring relay according to CEI 0-21 Menu structure Autotest menu Autotest routine Measurements V 27.S1 V 59.S1 V 27.S2 V: scrolling V 59.S1 T: V 59.S2 F: V 59.S1 OK V 59.S1 KO Password Autotest V: V: T: T: F: F: Events rec. V 27.S1 V 27.S2 V 59.S1 V 59.S2 F < 81.S1 F < 81.S2 F > 81.S1 F > 81.S2 10 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

11 Events menu Measurements Input / Output menu Measurements Password Autotest Events rec. I/O Managem. Connection Option Language Event: 0 type FF.Sx Vx T :00 - In the menu Events is recorded the ollowing inormation (up to 10 entries): - All protective unctions (27.S1 27.S2 59.S1 59.S2 -- <81.S1 <81.S2 >81.S1 >81.S2) - Last relay start-up - Auto-test Local Command Relay 2 Back-up Ext. Signal Event: 1 type FF.Sx Vx T :00 Rl 2 Logic Remote Trip Event: 10 type FF.Sx Vx T :00 Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

12 Grid eeding monitoring relay according to CEI 0-21 Menu structure Local command Local Command Relay 2 Back-up Ext. Signal First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. : (0-1) Local Command 0 Output relay 2, time delays Comando Loc. Local Command Relay 2 Back-up Ext. Signal First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. T1: ( ) ms T2: ( ) ms / LOCK Relay 2 T T Back up relay, logic and time delay Comando Loc. Local Command Relay 2 Back-up Ext. Signal First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. Tbu: ( ) ms Back-up Tbu 500 External signal logic Local Command Relay 2 Back-up Ext. Signal First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. : (0-1) Ext. Signal 0 Output relay 2 logic Comando Loc. Rl 2 Logic Remote Trip First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. Rl 2 Logic: (Pos-Neg) Rl 2 Logic Logic Pos 12 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

13 Remote trip logic Comando Loc. Rl 2 Logic Remote Trip First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. Logic: (Pos-Neg) Remote Trip Logic Pos Measurements connection Measurements I/O Managem. Connection Options Language First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. Type: (3 Ph 1 Ph) Connection Type 3 ph Language setting Measurements I/O Managem. Connection Options Language First enter the password, conirmation displayed by the asterisk shown at the ar right bottom o the display. With the buttons Up/Down the parameter value can be modiied. Lang: (Engl. Ita.) Language lang. Engl Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

14 Grid eeding monitoring relay according to CEI 0-21 Connection diagrams Application examples 1 + L N 21 L N L1 L2 L3 N Y10Y Y10Y CM-UFD CM-UFD U U F1 F1 F2 F2 A1 A2 A3 A4 Y20Y21 L1 L2 L3 N Y30 Y31 A1 A2 A3 A4 Y20Y21 L1 L2 L3 N Y30 Y G G 26 Legend 1) Control supply voltage or CM-UFD.M32 (SPI) relay and trip device coil (DDI) 2) Protection use or CM-UFD.M32 relay 3) Main circuit breaker DG or DGL 4) DDI short circuit protection 5) DDI: automatic circuit breaker or contactor equipped with low voltage coil and motor or automatic closure 6) Generator and/or inverter 7) Generator/inverter circuit breaker (DDG) 8) DDI auxiliary contact or eedback unction (P>20kW) 9) Shunt Trip coil or eedback unction (P>20kW). This coil can control DG/DGL or DDG devices Note: in accordance to CEI 0-21 regulation, in case o loss o control supply voltage it s asked to guarantee, at least or 5 seconds, the unctionality o the CM-UFD. M32, the operability o the DDI and when present the command coil or operating the redundancy device. This unction has to be realized by external buer or UPS devices. 14 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

15 Grid eeding monitoring relay according to CEI 0-21 Technical data Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuit - Supply circuit Rated control supply voltage U S A1-A2 230 V AC A3-A4 24 V AC/DC Tolerance o the rated control supply voltage U S % Rated requency DC and 50 Hz Frequency range AC Hz Typical current / power consumption 24 V DC 125 ma / 2,7 W 230 V AC 15 ma / 3 VA Power ailure buering time 5 s with external device (e.g CP-B) Input circuit - Measuring circuit L1, L2, L3, (N) Monitoring unctions according to CEI 0-21 ed. June 2012 Measuring ranges over-/undervoltage V AC (L1, L2, L3, N) V AC (L1, L2, L3) V AC (L1, N) over-/underrequency Hz Threshold values over-/undervoltage, 10 minutes average value overvoltage V AC,adjustable in 1 V steps (L1, L2, L3, N) V AC adjustable in 1V steps (L1, L2, L3) V AC adjustable in 1 V (L1, N) over-/underrequency Hz, adjustable in 0.01 Hz steps Hysteresis related to the threshold value undervoltage 2% overvoltage, 10 minutes average value 2% underrequency 2% overrequency 2% Accuracy o measurements voltage measurement ± 1 V ± 1 digit requency measurement ± 0,01 Hz ± 1 digit Display accuracy ± 1 digit (1 V or 0,01 Hz) Rated requency o measuring signal 50 Hz Frequency range o the measuring signal Hz Measuring principle TRMS Max. reaction time (Measuring cycle CM-UFD.M32 + < 30 ms switching time o the relays) without intentional delay Accuracy within the rated control supply voltage tolerance U 2 % Accuracy within the temperature range U 0,02 % / C Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

16 Grid eeding monitoring relay according to CEI 0-21 Technical data Input circuit - Feedback circuits Y10-Y11, Y20-Y21, Y30-Y31 Number 3 Kind o inputs eedback rom DDI auxiliary contact (Y10-Y11) isolated input or remote disconnection (Y20-Y21) isolated input or external signal (Y30-Y31) Electrical isolation rom supply voltage yes rom the measuring circuit yes rom the relay outputs yes Type o triggering ree voltage Max. switching current in the control circuit 60 ma Max. cable length at the control input 200 m No-load voltage at the control inputs 5 V DC Feedback time section switch 10 ms Timing circuits Start-up delay (prior to irst grid connection) 10 ms Start-up delay (display) 5 s Tripping delay adjustable see CEI 0-21 ed. June 2012 Adjustment range o the delay over-/undervoltage, over-/underrequency 0,05-5 s with 0,05 s steps Tolerance o the delay 5 ms Accuracy within the rated control supply voltage tolerance t 1 % ± 20 ms Indication o operational states See table LEDs, status inormation Display Backlighted yes Back light on pressing any key button o automatic, ater 5 minutes inactivity LCD clearly visible C LCD visible C Display area 27x 30 mm 16 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

17 Output circuits - Relay outputs Kind o outputs 11-12/14 relay, 1 c/o (SPDT) contact 21-22/24 relay, 1 c/o (SPDT) contact 31-32/34 relay, 1 c/o (SPDT) contact Operating principle 11-12/14 closed-circuit principle 21-22/24 open- or closed- circuit principle conigurable 31-32/34 open circuit principle Contact material AgNi Rated operational voltage Ue (IEC/EN ) 250 V AC Minimum switching voltage / minimum switching current 12 V / 10 ma Maximum switching voltage / maximum switching current 250V AC / 5A Rated operational current Ie (IEC/EN ) AC12 (resisitive) at 230 V 6 A AC15 (inductive) at 230 V 3 A DC12 (resistive) at 24 V 5 A DC13 (inductive) at 24 V 2 A Mechanical lietime 100 x 10 3 switching cycles Electrical lietime at standard condition 5 x 10 5 switching cycles Maximum use rating to achieve short-circuit protection n/c contact 15 A, operating class gg/gl n/o contact 15 A, operating class gg/gl Maximum closing current (short time) t<20ms 30 A t<80ms 17 A Conventional thermal current I th (IEC/EN ) 5 A User interace Buttons 4 key buttons or programming and scroll the menu General data MTBF on request Duty time 100% Dimensions (W x H x D) product dimensions 106,3 x 90,5 x 62 mm packaging dimensions 119 x 94 x 67 mm Weight net weight 0,395 kg gross weight 0,440 kg Mounting DIN rail (IEC/EN 60715) TH and TH 35-15, snapon mounting without any tool Mounting position any Minimum distance to other units vertical not necessary horizontal not necessary Material o housing policarbonate PBC Degree o protection housing / terminals IP40 / IP20 Electrical connection Wire size ine-strand with(out) wire end errule 1 x 0,5-1,5 mm 2 (1 x AWG) rigid 1 x 0,5-1,5 mm 2 (1 x AWG) Stripping length 7 mm (0,28 in) Tightening torque 0,35 Nm (3.1 lb.in) Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

18 Grid eeding monitoring relay according to CEI 0-21 Technical data Environmental data Ambient temperature ranges operation C storage C transport C Climatic category (EN 50178) 3K3 Vibration, sinusoidal (IEC/EN ) Class 1 Shock (IEC/EN ) Class 1 Isolation data Rated insulation voltage U i supply/measuring 424 V (EN 50178) mesuring/output 424 V supply/output 424 V output circuit 1/output circuit 2/output circuit V Rated impulse withstand voltage U imp supply/measuring/output circuits 5 kv (CEI 0-21, CEI 0-16 ) output circuit 1/output circuit 2/output circuit 3 4 kv (EN 50178) Basic insulation supply/measuring/output circuits 424 V output circuit 1/output circuit 2/output circuit V Test voltage, routine test supply/measuring/output circuits 2 kv output circuit 1/output circuit 2/output circuit 3 2 kv Test voltage, type test supply/measuring/output circuits 2 kv (CEI 0-21) output circuit 1/output circuit 2/output circuit 3 2 kv Protective separation (EN 50178) supply/measuring/output circuits 424 V output circuit 1/output circuit 2/output circuit V Pollution degree (EN 50178) 3 Overvoltage category (CEI 0-21) IV Standards / Directives Product standard IEC/EN Application standards CEI 0-21 ed Low Voltage Directive 2006/95/EU EMC Directive 2004/108/EU RoHS Directive 2002/95/EU Electromagnetic compatibility Intererence immunity to IEC/EN , CEI 0-21 Tab.11 Electrostatic discharge IEC/EN level 3, 6 kv / 8 kv Radiated, radio-requency, electromagnetic ield IEC/EN level 3, 10 V/m ( Mhz) level 2, 3 V/m ( Mhz) level 1, 1 V/m ( Mhz) Electrical ast transient / burst IEC/EN level 3 2 kv Surge IEC/EN level 3, 1 kv L-L, 2kV L-earth Conducted disturbances, induced by radio-requency ields IEC/EN level 3, 10 V Voltage dips IEC/EN % Us continuous, 80% Us max. 1 sec Short interruptions IEC/EN ms Voltage variations IEC/EN % Us continuous, 130% Us max. 1 sec. Intererence emission IEC/EN , IEC/EN High-requency radiated IEC/CISPR 22, EN class B High-requency conducted IEC/CISPR 22, EN class B 18 CM-UFD.M32 - Grid eeding monitoring relay according to CEI 0-21 Data sheet

19 Grid eeding monitoring relay according to CEI 0-21 Technical diagrams and dimensions Load limit curves Max. DC load breaking capacity Contact lietime DC voltage [V] Switching cycles resistive load 250VAC resistive load AgNi90/10 20 S0177-D 10 0,1 0,2 0, DC current [A] S0024-B Switching current [A] Dimensions in mm Further documentation Document title Document type Document number Electronic products and relays technical catalogue 2CDC C020x CM-UFD.M32 Grid eeding monitoring relay instruction sheet 1SVC M0000 Note: you can ind the documentation on the internet at -> Control Products -> Electronic Relays and Controls -> Three Phase Monitors. Data sheet CM-UFD.M32 - Grid eeding monitoring relay according to CEI

20 Contacts ABB STOTZ-KONTAKT GmbH P. O. Box Heidelberg, Germany Phone: +49 (0) Fax: +49 (0) ino.desto@de.abb.com You can ind the address o your local sales organisation on the ABB home page -> Low Voltage Products and Systems We reserve the right to make technical changes or modiy the contents o this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever or potential errors or possible lack o inormation in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization o its contents - in whole or in parts - is orbidden without prior written consent o ABB AG. Copyright 2013 ABB. All rights reserved. 2CDC D /2013

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks. 2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Three-phase monitoring relay CM-PBE

Three-phase monitoring relay CM-PBE Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of

More information

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage

More information

Liquid level monitoring relay CM-ENS.2x

Liquid level monitoring relay CM-ENS.2x Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 The three-phase monitoring relays CM-MPS.x3 monitor the phase parameters phase sequence, phase failure, over- and

More information

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact The CT-AHE is an electronic time relay with OFF-delay. t is from the CT-E range. The CT-E range is the economic range of ABB s time

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72 The three-phase monitoring relays CM-MPN.x2 monitor the phase parameters phase sequence, phase failure,

More information

Three-phase monitoring relay

Three-phase monitoring relay 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact Data sheet Electronic timer CT-AWE mpulse-off with auxiliary voltage, 1 c/o (SPDT) contact The CT-AWE is an electronic time relay with mpulse-off function. t is from the CT-E range. The CT-E range is the

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.

More information

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21 Data sheet Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21 The CM-UFD.M21 is a multifunctional grid feeding monitoring relay for three-phase mains. It provides different monitoring functions

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC Data sheet Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.x serves to monitor insulation resistance in accordance with IEC

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Three-phase monitoring relay

Three-phase monitoring relay 1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase

More information

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts The CT-MFS.21 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions, 10 time ranges

More information

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts The CT-MFS.21 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions, 10 time ranges

More information

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC

More information

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC Data sheet Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.1 serves to monitor insulation resistance in accordance with IEC

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC Data sheet Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN serves to monitor insulation resistance in accordance with

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Product group picture Product group picture /7 ABB Catalog Electronic Products and Relays 013/014 CDC 110 004 C009 Table of contents Three-phase monitoring relays Product group picture 7 Table of contents 8 Benefits and advantages,

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Product group picture Product group picture /7 ABB Catalog Electronic Products and Relays 015 CDC 110 004 C010 Table of contents Three-phase monitoring relays Benefits and advantages, Applications /9 Operating controls /30

More information

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Table of contents Table of contents Three-phase monitoring relays Three-phase monitoring relays 78 Benefits and advantages, Applications 79 Operating controls 80 Selection table - Singlefunctional 81 Ordering details -

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

Control module CP-A CM

Control module CP-A CM Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

Primary switch mode power supplies Product group picture

Primary switch mode power supplies Product group picture Primary switch mode power supplies Product group picture /1 ABB Catalog Electronic Products and Relays 2015 2CDC 110 004 C0210 Primary switch mode power supplies Table of contents Primary switch mode power

More information

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Pluggable interface relays CR-U Universal relays

Pluggable interface relays CR-U Universal relays Data sheet Pluggable interface relays CR-U Universal relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi Features Special relay for alternating loads, for applications with pumps, compressors, air conditioning or refrigeration units 2 independent NO output, 12 A 4 functions 2 independent control signals,

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

CM-IWM.11 Insulation monitoring relay

CM-IWM.11 Insulation monitoring relay Data sheet CM-IWM.11 Insulation monitoring relay The insulation monitor CM-IWM.11 provides best and up to date insulation monitoring of modern IT systems in an optimum and state of the art way fulfilling

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with

More information

Multi-voltage Multi-function. Wiring diagram (without control signal)

Multi-voltage Multi-function. Wiring diagram (without control signal) 80 Modular timers 16 A 80 Multi-function and mono-function timer range 80.01T - Multi-function & multi-voltage 80.11T - On-delay, multi-voltage Complies with EN 45545-2:2013 (protection against fire of

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric

More information