ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Size: px
Start display at page:

Download "ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch"

Transcription

1 ECHOTEL 915 series 2 Wire, current shift Ultrasonic level switch DESCRIPTION Echotel 915 series ultrasonic level controls are 2 wire (24 V DC) integral units which utilize pulsed wave technology to detect high or low level alarm in a broad range of viscous to light liquids. The 915 series has protected electronics, and its high frequency signal prevents the unit from picking up noise from surrounding equipment such as engines, pumps etc... Compact and universal level switch FEATURES No calibration. 2-Wire loop powered intrinsically safe design. Continuous selftest with separate error signal. Metal and plastic transducers. High or low level detection - field selectable. High pressure / temperature ratings: - metal transducers: max C - Kynar (PVDF) transducers: max 19 bar / max +120 C. Suited for SIL 1, 2 and 3 loops (full FMEDA report by exida available) Threaded Echotel 915 with Kynar transducer SAFETY INTEGRITY LEVEL APPLICATIONS LIQUIDS: Any liquids with a viscosity < cp. VESSELS: Any mounting position. PROCESS CONDITIONS: Unaffected by - shifting dielectric, density, or PH - presence of foam, turbulence, visible vapors - fast drain/fill rates - transducer coating and air bubbles - vacuum conditions. AGENCY APPROVALS ➀ ➁ Agency ATEX Approval TÜV WHG 19 II 1G EEx ia II C T6/T5, intrinsically safe ➀ II 1/2 G EEx d II C T6, explosion proof ➀ AIB VLAREM II FM/CSA ➁ GOST/ GOSGORTECHNADZOR ➁ Flanged Echotel 915 with metal transducer Non incendive / intrinsically safe / explosion proof Only for metal sensors. Consult factory for correct model numbers Russian Authorisation Standards Worldwide level and flow solutions

2 PRINCIPLE OF OPERATION The Echotel 915 operates on a two crystal pulsed or transmit-receive principle which applies a high frequency electronic burst to the transmit crystal. The signal is then converted into ultrasonic energy and transmitted across the sensing gap toward the receiver crystal. When there is air in the gap, the high frequency ultrasonic energy will be attenuated, thereby not allowing the energy to be received. When there is liquid in the gap, the ultrasonic energy will propagate across the gap and the current shift output will indicate a reception of the signal. ma Normal Alarm T R T R Error signal Normal operation Error Air/Gas Dry gap Liquid Wet gap MOUNTING Ambient temperature: -40 C (-40 F) to +70 C (+160 F) Filling line Hi alarm Lo alarm Hi alarm Max pressure: metal transducer: 103 bar (1500 PSIG) Kynar transducer: 19 bar (275 PSIG) Lo alarm Max temp: metal transducer: +150 C (+300 F) Kynar transducer: +120 C (+250 F) Min temp: -40 C (-40 F) Pump protection Pump PERFORMANCE SPECIFICATIONS Description Specification Response time 0,15 s typical Repeatability ±2 mm (0.078") Ambient Temperature -40 C up to +70 C (-40 F to +160 F) Humidity 0-99 %, non condensing Electromagnetic Compatibility Meets CE requirements (EN , EN ) and NAMUR NE 21 2

3 PHYSICAL/FUNCTIONAL SPECIFICATIONS Description Input Voltage Power Consumption Signal Output Indication Housing material Approvals Normal operation Alarm Malfunction Normal operation Alarm Malfunction ATEX (metal transducers) FM/CSA Specification V DC (24 V DC) 2 wire loop powered 1 Watt maximum 16 ma ± 1 ma 8 ma ± 1 ma 5 ma ± 1 ma Green LED on Red LED on No LED s on IP65, cast aluminium or stainless steel II 1 G EEx ia II C T6, intrinsically safe - ambient temp. up to +55 C (+130 F) II 1 G EEx ia II C T5, intrinsically safe - ambient temp. up to +70 C (+160 F) II 1/2 G EEx d II C T6, explosion proof Non incendive, intrinsically safe and explosion proof Overfill Prevention TÜV - WHG 19 / VLAREM II SIL (Safety Integrity Level) Functional safety to SIL 2 loops / SIL 3 loops (redundant installation) full FMEDA report by Exida available Electrical data Ui = 28,4 V, li = 94 ma, Pi = 0,67 W Equivalent data Ci = 25 nf, Li = 400 µh Shock/Vibration ANSI/ISA-dS71.03 SA1 (shock), ANSI/ISA-dS71.03 VC2 (vibration) Net Weight 1,6 kg / 3.5 lbs (unit with 50 mm SST transducer) TRANSDUCERS SPECIFICATIONS Description 9W1 transducers (plastic) 9D1 transducers (metal) Transducer materials Kynar (PVDF) 316/316L SST (1.4401/1.4404) Hastelloy C (2.4819) Monel (2.4360) Mounting Threaded (NPT) Flanged (ANSI - EN/DIN) Actuation length From 40 mm up to 3300 mm (2" up to 130") From 30 mm up to 3300 mm (1" up to 130") Max process temp. -40 C up to 120 C (-40 F up to 250 F) -40 C up to 150 C (-40 F up to 300 F) Max pressure C ( F) C (1500 psi up to 300 F) Flanged models are downrated to the design pressure of the selected flange Max viscosity cp ELECTRICAL WIRING Hazardous area (915-P) Safe area 2-wire, loop powered or Electronic module 3

4 ECHOTEL 915-W: with Kynar Dimensions in mm (inches) (PVDF) transducer Ø 118 (4.63) 76 (3) Ø 118 (4.63) 76 (3) 70 (2.75) 70 (2.75) 97 (3.80 ) 114 ( 4.49) 20 ( 0.79) Actuation length Actuation length 6 (0.25) 6 (0.25) Ø 21 (0.84) Threaded unit Ø 21 (0.84) Flanged unit Pressure/Temperature Rating bar (psi) 20 (290) Process pressure 15 (217) 10 (145) ANSI RF Flange DIN Flange 5 (72) 3/4" NPT Threaded -40 (-40) 0 (32) 40 (100) 80 (176) 120 (250) C ( F) Process temperature 4 EXPEDITE SHIP PLAN (ESP) Several Echotel 915 units are available for quick shipment, within max. 3 weeks after factory receipt of purchase order, through the Expedite Ship Plan (ESP). Models covered by ESP service are conveniently grey coded in the selection data charts. To take advantage of ESP, simply match the colour grey model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options.

5 ECHOTEL 915-W: with Kynar Selection data A complete measuring system consists of: (PVDF) transducer 1. One order code for electronics 2. One order code for Kynar (PVDF) transducer 1. Order code for Echotel 915-W electronics 2-wire, 24 V DC potted electronics with 8 or 16 ma output 5 ma error signal BASIC MODEL NUMBER W Echotel 915-W electronics for Kynar (PVDF) transducers OUTPUT 2 2 A 2-wire loop powered electronics with Current shift output HOUSING MATERIAL / CABLE ENTRY / IP65 - WHG Aluminium M20 x 1,5 general purpose 0 I 0 Aluminium 3/4" NPT general purpose 0 Y 0 Stainless steel 3/4" NPT general purpose W 2 2 A 0 0 complete order code for Echotel 915 electronics 2. Order code for kynar transducer BASIC MODEL NUMBER 9 W 1 Echotel 915-W Kynar transducer PROCESS CONNECTION Threaded 1 Threaded 3/4" NPT connection ANSI RF Flanges in 316/316L SST (1.4401/1.4404) with Kynar (PVDF) facing B 1" 150 lbs - Raised Face C 1 1/2" 150 lbs - Raised Face D 2" 150 lbs - Raised Face EN/DIN Flanges in 316/316L SST (1.4401/1.4404) with Kynar (PVDF) facing K DN 25 PN16 EN Type A M DN 50 PN16 EN Type A TRANSDUCER MATERIAL K K M Kynar (PVDF) ACTUATION LENGTH specify in cm (0.39") increments Total length = actuation length + 6 mm (0.25") mm - min actuation length for threaded process connection mm - min actuation length for flanged process connection mm - standard ESP actuation length for threaded process connection mm - maximum actuation length 9 W 1 K K M complete order code for Echotel 915-W kynar transducer 5

6 ECHOTEL 915-P: with metal transducer Dimensions in mm (inches) Ø 118 (4.63) 76 (3) Ø 118 (4.63) 76 (3) 70 (2.75) 70 (2.75) 68 (2.67) 97 (3.80 ) 20 (0.79) Actuation Length for 3/4" NPT connection Actuation Length for 1" BSP (G1) connection Actuation 6 (0.25) 6 (0.25) Ø 22 (0.875) Ø 22 (0.875) Threaded unit Flanged unit Selection data A complete measuring system consists of: 1. One order code for electronics 2. One order code for metal transducer 1. Order code for Echotel 915-P electronics 2-wire, 24 V DC potted electronics with 8 or 16 ma output 5 ma error signal SENSOR MATERIAL P 2 2 A Echotel 915P electronics for 316/316L (1.4401/1.4404) SST transducer P 3 2 A Echotel 915P electronics for Monel (2.4360) transducers / Hastelloy C (2.4819) transducers (transducer materials Code MM and HC) HOUSING MATERIAL / CABLE ENTRY / SAFETY APPROVAL IP Aluminium M20 x 1,5 general purpose and ATEX intrinsically safe 0 I 0 Aluminium 3/4" NPT general purpose and ATEX intrinsically safe 0 Y 0 Stainless steel 3/4" NPT general purpose and ATEX intrinsically safe HOUSING MATERIAL / CABLE ENTRY / SAFETY APPROVAL IP65 0 T 0 Aluminium M20 x 1,5 ATEX explosion proof 0 K 0 Aluminium 3/4" NPT ATEX explosion proof P 2 A 0 0 complete order code for Echotel 915-P electronics 6

7 ECHOTEL 915-P: with metal transducer Selection data 2. Order code for Echotel 915-P transducer BASIC MODEL NUMBER 9 D 1 Echotel 915-P metal transducers PROCESS CONNECTION Threaded 1 Threaded 3/4" NPT connection 2 Threaded 1" NPT connection 9 Threaded 1" BSP (G1) connection (minimum length transducer = 50 mm (2") ANSI RF Flanges B 1" 150 lbs - Raised Face C 1 1/2" 150 lbs - Raised Face D 2" 150 lbs - Raised Face E 1" 300 lbs - Raised Face F 1 1/2" 300 lbs - Raised Face G 2" 300 lbs - Raised Face H 1" 600 lbs - Raised Face J 2" 600 lbs - Raised Face EN/DIN Flanges K DN 25/PN 16, EN Type A L DN 40/PN 16, EN Type A M DN 50/PN 16, EN Type A N DN 25/PN 25, EN Type A P DN 40/PN 25, EN Type A Q DN 50/PN 25, EN Type A R DN 25/PN 40, EN Type A S DN 40/PN 40, EN Type A T DN 50/PN 40, EN Type A U DN 25/PN 63, EN Type B2 V DN 40/PN 63, EN Type B2 W DN 50/PN 63, EN Type B2 X DN 25/PN 100, EN Type B2 Y DN 40/PN 100, EN Type B2 Z DN 50/PN 100, EN Type B2 TRANSDUCER MATERIALS /316L (1.4401/1.4404) - only for Echotel P22A HC1 Hastelloy C (2.4819) - only for Echotel P32A MM 1 Monel (2.4360) - only for Echotel P32A ACTUATION LENGTH specify in cm (per 0.39") increments Total insertion length = actuation length + 6 mm (0.25") mm - min actuation length for NPT threaded process connections mm - min actuation length for 1" BSP (G1) / flanged process connections mm - maximum actuation length 9 D 1 1 complete order code for Echotel 915-P transducer 7

8 QUALITY ASSURANCE - ISO 9001:2000 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2000 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. :2000 PRODUCT WARRANTY ALL MAGNETROL ELECTRONIC AND ULTRASONIC LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORK- MANSHIP FOR ONE FULL YEAR FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPEC- TION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN TRANSPORTATION. MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME MAGNETROL PRODUCTS. UNDER RESERVE OF MODIFICATIONS BENELUX Heikensstraat 6, 9240 Zele, België Tel. +32 (0) Fax. +32 (0) info@magnetrol.be DEUTSCHLAND Alte Ziegelei 2-4, D Overath Tel / Fax / vertrieb@magnetrol.de FRANCE 40-42, rue Gabriel Péri, Le Plessis Bouchard Tél Fax magnetrolfrance@magnetrol.fr ITALIA Via Arese 12, I Milano Tel. (02) (R.A.) Fax. (02) mit.gen@magnetrol.it UNITED Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL KINGDOM Tel. (01444) Fax (01444) sales@magnetrol.co.uk INDIA E-22, Anand Niketan, New Delhi Tel. 91 (11) Fax 91 (11) info@magnetrolindia.com OUR NEAREST REPRESENTATIVE BULLETIN N : BE EFFECTIVE: MAY 2005 SUPERSEDES: October 2003

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S ECHOTEL 961/962 Ultrasonic level switches D E S C R I P T I O N The Echotel 961/962 series utilizes pulse signal technology to detect high or low level alarm(s) in a broad range of viscous to light liquids.

More information

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications

ECHOTEL 961. Ultrasonic level switches FOR HYGIENIC USE. Worldwide level and flow solutions. For LIQUID LEVEL switching applications ECHOTEL 961 Ultrasonic level switches FOR HYGIENIC USE D E S C R I P T I O N Echotel 961 ultrasonic level switches require no calibration to detect the presence of any liquid in less than 1s. Foam is ignored

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

ECHOTEL 961/962 LINE POWERED

ECHOTEL 961/962 LINE POWERED ECHOTEL 961/962 LINE POWERED Installation and Operating Manual Ultrasonic Single and Dual Point Level Switches Model 961 Model 962 UNPACKING Unpack the instrument carefully. Make sure all components have

More information

ECHOTEL 961/962 LINE POWERED

ECHOTEL 961/962 LINE POWERED ECHOTEL 961/962 LINE POWERED Installation and Operating Manual Ultrasonic Single and Dual Point Level Switches Model 961 Model 962 UNPACKING Unpack the instrument carefully. Make sure all components have

More information

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications

Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications Echotel Model 961 Ultrasonic Level Switches for Hygienic Applications D E S C R I P T I O N Echotel Model 961 Ultrasonic Level Switches use pulsed signal technology for superior performance in difficult

More information

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Trident 91S/92S Ultrasonic Level Switches Echotel Trident 91S/92S Ultrasonic Level Switches D E S C R I P T I O N The Trident 91S/92S detects single or dual point level in a wide variety of liquid applications. It is available with either an ma

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

Guided Wave Radar Liquid-Liquid Interface Transmitter

Guided Wave Radar Liquid-Liquid Interface Transmitter Guided Wave Radar Liquid-Liquid Interface Transmitter TM 707 DESCRIPTION The Eclipse 707 Transmitter is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided Wave Radar (GWR)

More information

Kotron Model 82 CE RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art

More information

Echotel Model 911/921 Ultrasonic Level Switches

Echotel Model 911/921 Ultrasonic Level Switches Echotel Model 911/921 Ultrasonic Level Switches D E S C R I P T I O N Echotel Model 911/921 ultrasonic level switches sense the presence or absence of liquids in a transducer gap by utilizing continuous

More information

HORIZON 704. Guided Wave Radar Level Transmitter. Worldwide level and flow solutions

HORIZON 704. Guided Wave Radar Level Transmitter. Worldwide level and flow solutions HORIZON 704 Guided Wave Radar Level Transmitter DESCRIPTION The Horizon 704 is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided Wave Radar (GWR) technology. The electronics

More information

JUPITER 200. Magnetostrictive Level Transmitter. Worldwide level and flow solutions. Measures «LEVEL» and «INTERFACE» D E S C R I P T I O N

JUPITER 200. Magnetostrictive Level Transmitter. Worldwide level and flow solutions. Measures «LEVEL» and «INTERFACE» D E S C R I P T I O N JUPITER 200 Magnetostrictive Level Transmitter D E S C R I P T I O N The Jupiter 200 transmitter is a loop-powered, 24 V DC liquid-level transmitter and utilises the effect of a magnetic field on the magnetostrictive

More information

Solitel Vibrating Rod Level Switch

Solitel Vibrating Rod Level Switch Solitel Vibrating Rod Level Switch D E S C R I P T I O N Solitel Vibrating Rod Level Switches provide reliable level detection of powders and bulk solids. This compact, integral switch is suitable for

More information

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow DESCRIPTION Echotel Model 338 is a two-wire, loop-powered noncontact transmitter for liquid level,

More information

Solitel Vibrating Rod Level Switch

Solitel Vibrating Rod Level Switch Solitel Vibrating Rod Level Switch DESCRIPTION Solitel Vibrating Rod Level Switches provide reliable level detection of powders and bulk solids. This compact, integral switch is suitable for high or low

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display

More information

THERMATEL MODEL TG1/TG2

THERMATEL MODEL TG1/TG2 THERMATEL MODEL TG1/TG2 Installation and Operating Manual Thermal Dispersion Level/Flow/Interface Switch Model TG1/TG2 with twin tip sensor Model TG1/TG2 with spherical tip sensor Model TG1/TG2 with low

More information

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches Kotron Sentinel Models 8, 8 and 84 RF Point Level Switches D E S C R I P T I O N The Sentinel is a powerful multi-point level switch. The microprocessor-based circuitry has non-volatile memory, to protect

More information

Echotel Model 961/962 Ultrasonic Level Switches

Echotel Model 961/962 Ultrasonic Level Switches Echotel Model 961/962 Ultrasonic Level Switches D E S C R I P T I O N Increasing demands for compliance with safety systems and overfill protection has mandated more reliable point level measurement. Echotel

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display

More information

E3 Modulevel. Displacer operated level transmitter. Worldwide level and flow solutions. D E S C R I P T I O N

E3 Modulevel. Displacer operated level transmitter. Worldwide level and flow solutions.   D E S C R I P T I O N E3 Modulevel Displacer operated level transmitter www.modulevel.magnetrol.com D E S C R I P T I O N E3 Modulevels are 2 wire, loop powered level transmitters utilising buoyancy principle to detect and

More information

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow

Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow Echotel Models 344/345 Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow D E S C R I P T I O N Echotel Models 344 and 345 are full-featured, ultrasonic non-contact transmitters

More information

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow Echotel Model 355 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow D E S C R I P T I O N Echotel Model 355 is a two-wire, loop-powered, noncontact ultrasonic transmitter

More information

ECHOTEL CONTACT ULTRASOUND. Worldwide Level and Flow Solutions SM

ECHOTEL CONTACT ULTRASOUND. Worldwide Level and Flow Solutions SM ECHOTEL CONTACT ULTRASOUND Worldwide Level and Flow Solutions SM The Total Spectrum of Solutions Magnetrol products employ a number of technologies to meet the challenges of level and flow measurement.

More information

E3 Modulevel. Displacer operated level transmitter A G E N C Y A P P R O VA L S. For continuous level, density or liquid-liquid interface

E3 Modulevel. Displacer operated level transmitter A G E N C Y A P P R O VA L S. For continuous level, density or liquid-liquid interface E3 Modulevel Displacer operated level transmitter D E S C R I P T I O N E3 Modulevels are 2 wire, loop powered level transmitters utilising buoyancy principle to detect and convert liquid level changes

More information

H O R I Z O N G U I D E D W A V E R A D A R

H O R I Z O N G U I D E D W A V E R A D A R H O R I Z O N G U I D E D W A V E R A D A R An Introduction To Horizon Guided Wave Radar H orizon transmitters utilize Guided Wave Radar (GWR) technology for unsurpassed accuracy and reliability in monitoring

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

Horizon Model 704 Guided Wave Radar Level Transmitter

Horizon Model 704 Guided Wave Radar Level Transmitter Horizon Model 704 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Horizon Model 704 Transmitter is an intermediately priced 24 VDC, loop-powered, liquid level transmitter based upon Guided

More information

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter Magnetostrictive Transmitters D E S C R I P T I O N The Enhanced Jupiter Magnetostrictive level transmitter provides a 4 20 ma output proportional to the level being measured or FOUNDATION fieldbus output.

More information

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Enhanced Eclipse Model 705 Transmitter is a looppowered, 24 VDC liquid-level transmitter based on the revolutionary

More information

Guided Wave Radar Level Transmitter

Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter 705 D E S C R I P T I O N The Eclipse 705 Transmitter is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided Wave Radar (GWR) technology.

More information

2-wire level transmitter

2-wire level transmitter Badger Meter Europa GmbH 2-wire level transmitter Model L2xx INSTALLATION AND OPERATION MANUAL July 2002 Version UF-L2xx-07/02-e Contents Contents Page 1. Installation 1 1.1 Mounting the instrument 1 1.2

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter

Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter Eclipse Enhanced Model 705 Guided Wave Radar Level Transmitter D E S C R I P T I O N The Enhanced Eclipse Model 705 Transmitter is a looppowered, 24 VDC liquid-level transmitter based on the revolutionary

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Guided Wave Radar Level Transmitter

Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter www.eclipse.magnetrol.com 705 D E S C R I P T I O N The Eclipse 705 Transmitter is a loop-powered, 24 V DC liquid-level transmitter based on the revolutionary Guided

More information

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications

Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications Eclipse Enhanced Model 705 GWR Level Transmitter for Hygienic Applications D E S C R I P T I O N The Enhanced Eclipse Model 705 is a loop-powered, 24 VDC, level transmitter based upon the revolutionary

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

Liquid Level Switches

Liquid Level Switches Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange,

More information

Ultrasonic Liquid Level Transmitters

Ultrasonic Liquid Level Transmitters Product Data Sheet Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Technologies, Solutions, and Applications. Level Switching

Technologies, Solutions, and Applications. Level Switching Technologies, Solutions, and Applications Level Switching Contents Leadership in Level Switching 3 How We Earn Your Business 4 Models & Versions 5 About Level Switching 11 Assurance with Redundant Systems

More information

Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch

Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch Thermatel Model TD1/TD2 Thermal Dispersion Flow/Level/Interface Switch D E S C R I P T I O N Thermatel Model TD1 and TD2 Thermal Dispersion flow/level/interface switches provide a new level of performance

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

PULSAR PULSE BURST RADAR

PULSAR PULSE BURST RADAR TM PULSAR PULSE BURST RADAR The Total Spectrum of Solutions Magnetrol s products employ a number of technologies to meet the challenges of level and flow control. Pulsar transmitters utilize Pulse Burst

More information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level gauges Series LT Level indicator, switch and transmitter for liquids Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance

More information

PRODUCT LINE QUICK REFERENCE

PRODUCT LINE QUICK REFERENCE PRODUCT LINE QUICK REFERENCE Worldwide Level and Flow Solutions SM SOFTWARE GUIDED WAVE RADAR RADAR PACTware Eclipse Pulsar Pulsar Radar Process Automation PC Software Description: PACTware (Process Automation

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Advanced Guided Wave Radar Transmitter for Level Measurement and Control

Advanced Guided Wave Radar Transmitter for Level Measurement and Control Advanced Guided Wave Radar Transmitter for Level Measurement and Control ECLIPSE Guided Wave Radar Magnetrol pioneered guided wave radar (GWR) by introducing the ECLIPSE Model 705 two-wire, loop-powered

More information

Level measurement Radar

Level measurement Radar Level measurement Radar Overview 6 VEGAPULS series 60 8 Dimensions 20 AL-EN - 5 Level measurement Radar VEGAPULS: Non-contact measurement of liquids and solids under arduous process conditions Measuring

More information

Rod probe With coaxial tube reference probe

Rod probe With coaxial tube reference probe Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Full Metal Variable Area Flowmeter and Counter Model BGF

Full Metal Variable Area Flowmeter and Counter Model BGF Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20

More information

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS 3 YEARS WARRANTY PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS MAIN FEATURES 2-wire K-band Pulse Burst Radar 25 GHz frequency

More information

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 500 Humbolt Street Los Alamitos, CA 9. If for

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

PRODUCT LINE CATALOGUE

PRODUCT LINE CATALOGUE PRODUCT LINE CATALOGUE Worldwide Level and Flow Solutions SM VISION STATEMENT To be the customers preferred partner in the global supply of level and flow control solutions 2 COMPANY COMPANY Industry leader

More information

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202 MEGGITT MOBREY LTD MOBREY SQUING Vibrating fork liquid level switch Universal level switch High level alarm duty Overfilling prevention Intrinsically safe models Marine approved models FEATURES Small &

More information

Ultrasonic level measuring device, non-contact

Ultrasonic level measuring device, non-contact Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Princo MagneLevel Model LML

Princo MagneLevel Model LML Instrumentation designed with the user in mind Instruction Manual Princo MagneLevel Model LML Two-Wire Magnetic Coupled Level Transmitter 11 Nov 05 PRINCO INSTRUMENTS INC., 1020 INDUSTRIAL BLVD., SOUTHAMPTON,

More information

Model R82 Pulse Burst Radar Level Transmitter

Model R82 Pulse Burst Radar Level Transmitter Model R82 Pulse Burst Radar Level Transmitter D E S C R I P T I O N The Magnetrol Model R82 is an economical, loop-powered radar transmitter bringing radar to everyday applications. Applications that have

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below BLISSFLEX 1100 The characters of the order code have been described below BA25 4 BLISSFLEX 1100 C 2-wire loop-powered 4...20 ma Guided Radar (TDR) level meter: -50...+100 C and -1...16 barg / -58...212

More information

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Presented to valued clients attending the Technology Summit hosted by: Kendall Group/ J.O.Galloup +GF+ Offering Level Measurement Continuous

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Level and Pressure. Product Information. Vibrating level switches

Level and Pressure. Product Information. Vibrating level switches Level and Pressure Product Information Vibrating level switches Contents Contents 1 Product description 1.1 VEGAVIB... 3 1.2 VEGASWING... 3 2 Function and application 2.1 Functional principle... 5 2.2

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

E C L I P S E G U I D E D W A V E R A D A R

E C L I P S E G U I D E D W A V E R A D A R E C L I P S E G U I D E D W A V E R A D A R The Total Spectrum of Solutions Magnetrol s products employ a number of technologies to meet the challenges of level and flow control. Eclipse transmitters utilize

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

Guided Wave Radar Level and Interface Transmitter

Guided Wave Radar Level and Interface Transmitter Product Data Sheet Online Only The Rosemount 3300 Series consists of smart, loop-powered level and interface transmitters based on guided wave radar technology. These instruments provide outstanding reliable

More information

Miniature resistance thermometer Model TR33, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information