ZAST Addendum. Damping

Size: px
Start display at page:

Download "ZAST Addendum. Damping"

Transcription

1 1 ZAST Addendum Damping I am a little embarrassed to admit that until I have overlooked something which could be important, particularly to those who found the treatment, specifically Z2 treatment to be painful. I suppose you can t see the wood for the trees might be appropriate here. Several people have given up with this due to issues with pain, this could well overcome that issue. There is a setting on your device called damping (Dmp or Dmpf on some devices). Damping takes the edge off the signal, it removes the sharpness. You can choose Sk1, Sk2, Sk3, Sk4 or Var. Don t use Var (variable) as it won t be suitable here. On some devices it is Sc not Sk. I have connected a scenar to an oscilloscope; an oscilloscope is a device that allows signal voltages to be viewed as a graph. The basic signal component of scenar is a bipolar impulse, consisting of a negative square-wave followed by a positive saw-tooth, starting and finishing at zero. You can see this in the image below. The voltage is shown on the Y axis (up/down), positive from middle up and negative from middle down. Time is shown on the X axis (positive time travelling to the right). My oscilloscope is old and I cannot produce its image on any other device so a photo of the screen is the best I can do right now. Note: all of the images of waveforms in this file are when the device is not in contact with the skin. Normally the waveform of one impluse looks like this.

2 2 If you change Dmpf=0ff to Dmpf=Sk1, the resultant signal is as follows increase again and it damps further until Sk4: If you are having problems with pain, add damping and try again. Sk1 should be enough, but feel free to try Sk2, 3 or 4. But the greater the damping the greater the impact is compromised, so find a balance that is right for you. Adding damping should allow you to increase the energy further, and generate more zeffles!

3 3 Impulse, Frequency, Intensity and Gap Here I am going to show you the scenar waveform and its relationship with frequency, intensity and gap. You will have used frequency but maybe not intensity and gap. Impulse Normally the waveform of one impluse looks like this. The setting on the oscillioscope is 0.2ms/div (0.2 milliseconds per division) Each division is the width of one black square. You can see that if the impulse begins at A and ends roughly at B, it covers about 5 squares, therefore if one division is 0.2ms, 5 divisions is 1ms, so therefore the impulse is 1ms long (or seconds).

4 4 Frequency I have now changed the oscilloscope to view the image of the waveform at 1ms/div. This means that the image of the wave has been compacted 5 times from the previous image, which is why they look like straight lines. Here is the result, it shows 4 impulses. The vertical lines are actually 4 of the impulses of the previous image. You can see the impulses repeating at regular intervals. You are looking at what s happening in one fraction of a second in time. Knowing the setting is 1ms/div, you can estimate the frequency at which the scenar is operating. Here is how: I estimate that the gap between C and D to be 3.2 divisions, of course I could choose any of the three visible gaps. If the oscilloscope is displaying at 1ms/div, the gap between impulses is 3.2ms, this is called the period of the wave Frequency is the reciprocal of the period, ie. Frequency = 1 divided by the period Therefore apparent frequency of scenar is 1 / 3.2ms = 312.5Hz (Hz =1/s). The actual frequency on the device was 321Hz, so not far off! So what this means is that at 321Hz, there are 321 impulses occurring in one second. OK so far? If not read this again until you are, otherwise the rest won t make sense either.

5 5 Intensity and Gap If you increase intensity (Int on the device) from 1 to 2 you are adding another impulse (exactly the same as the other impulses). Only impulses C and D would appear if the intensity was 1 (like the previous image), but as the intensity has been increased to 2, additional impulses E and F are observed almost immediately after the first impulse. The distance between these impulses is defined by the gap (reffered to as Z on some devices), and is much smaller than that defined by the frequency. Knowing the setting on the oscilloscope we can not only estimate the frequency but also the pulse repetition frequency (PRF). The PRF is the frequency defined by the gap between the impulses in a batch, ie. between C and E (or D and F for that matter), where a batch is the number of impulses defined by the intensity setting, so in this case there is 2 in the batch. Firstly you can estimate the frequency: Again the oscilloscope is displaying at 1ms/div. So calculating the frequency at which the scenar is operating: Remember we are measuring the distance (in time) between the first impulses in each batch, I estimate that the gap between each C and D (or E and F for that matter) to be 5.8 divisions If the oscilloscope is displaying at 1ms/div, the gap between first impulses is 5.8ms Therefore Frequency of scenar is 1 / 5.8ms = 172Hz. The actual frequency on the device was 181Hz, so again, not far off.

6 6 Now estimating the PRF: I estimate that the gap between C and E to be 0.9 divisions If the oscilloscope is displaying at 1ms/div, the gap between impulses is 0.9ms Therefore the apparent PRF of scenar is 1 / 0.9ms = 1.11KHz. The actual PRF is not displayed on the device; however it can be simply calculated using an equation. We know that Gap on the device (Z on some devices) is a number representing this gap. I know this relationship to the actual gap is 20µs x Gap, that is 20 microseconds x Gap. I know that the gap on the device was set at 40, so actual gap is 20µs x 40 = 800µs. This is nearly the answer but not quite! A small factor needs to be included here The energy level has a slight influence upon the PRF. This shows the negative square wave of the very beginning of the impulse, as energy is increased on the device, the square wave gets larger and the gap between G and H increases. Consequently this pushes each impulse further away from each other. The effect on frequency is negligible but is worthy of consideration when calculating the PRF. The factor is an addition of (2µs x energy), this is an approximation, but is good enough. Therefore: PRF = 1 / ((20µs x Gap) + (2µs x energy)) My energy level was set at 50 So in my example PRF = 1 / (800µs + 100µs) = 1 / 900µs = 1.11KHz, which is exactly what was estimated! I acquired this equation from Dr Hans Bruendler

7 7 I can reinforce this notion further: Here is part of the manual for the Scenar NT So to confirm the equation is correct, we insert the values to check it PRF = 1 / ((20µs x Gap) + (2µs x energy)) Maximum energy = 250 Maximum Z = 80 PRF = 1 / ((20µs x 80) + (2µs x 250)) = 476Hz, This is quite a way off the stated 540Hz, however, notice that if maximum energy = 125 PRF = 1 / ((20µs x 80) + (2µs x 125)) = 540Hz, which is exact! The use of energy 125 might be an error in the manual, or maybe they thought 250 energy was just way too high! Lets try the next one PRF = 1 / ((20µs x Gap) + (2µs x energy)) Lowest energy = 1 Lowest Z = 10 PRF = 1 / ((20µs x 10) + (2µs x 1)) = 4950Hz This is quite a way off the stated 4500Hz, however, notice that if minimum energy = 10 PRF = 1 / ((20µs x 10) + (2µs x 10)) = 4545Hz or 4.5Kz which is exact! The lowest energy level on the 97.4 scenar is 10, so it is probably based on that value. What I found reassuring was that as I reduced the gap, the pitch of the sound from the device increased. Try this yourself at a high energy value, so it is audible. I acquired the following table from Professor Revenko s wife Galina, the readings of which correspond exactly with the equation: PRF = 1 / ((20µs x Gap) + (2µs x energy)) Try some of the values yourself A is energy level.

8 8 Z A F Z = 80 - const А=10 А=50 А=100 А=250 Z = 70 - const А=10 А=50 А=100 А=250 Z = 60 - const A = 10 Z = 50 - const A = 10 Z = 40 - const A = 10 Z = 30 - const A = 10 Z = 20 const A = 10 Z = 10 - const A =

9 9 As a further demonstration the following shows the device set at Intensity 7, frequency 181Hz and gap is 25. This is an example of the device at its limit. There is a cut off point where the gap between final impulse in batch and first impulse in next batch ( ie. between J and K) can not fall below a certain distance value. This means that in this instance, although the intensity on the device can go up to 8, you cannot increase to 8 here, without reducing the gap or frequency. J and K are as close together as they can be. However, if you reduce frequency or gap, J and K will move further apart leaving room for impulse number 8 if required. So at least it seems clear that that is how to calculate the PRF. So what? How does this help? My theory is that the in the Z2 position the signal travels around the inner/middle ear area and in particular stimulates the cochlea. The device is operating at a particular frequency, and it seems that that frequency refers to a position inside the cochlea. This idea is reinforced by the resultant zeffles, which I believe are the hair cells being stimulated. The frequency on the device goes to 351Hz ( or 354Hz, depending on the model). My theory is that this refers to a position somewhere in the cochlea, but as yet we don t know where. Also this frequency will relate to a frequency on the audio scale, for example 351Hz on scenar might refer to around 14KHz on the audio scale. So if your damaged hair cells are in an area that is above this range then we need to look at how to get the scenar to emit a frequency above 351Hz. Using intensity and gap seems like the way to do it, but also it is not 100% clear.

10 10 Some have said that a higher frequency can be achieved by simply increasing intensity, they think it doubles the frequency. So at 351Hz and intensity 2, the resultant frequency is 702Hz. I do not believe this is correct. The image on page 5 is an example of this setting. Although there may be 702 impulses in one second, each impulse is not at the same regular interval, therefore this cannot be the frequency. I believe that it simply does not have a simple resultant frequency, it is more complicated than that. This view may have come about because it simply hasn t been explored because it hasn t been necessary to do this in their application of the device, perhaps an assumption. Look at the image on page 9, it is quite clear that the more dominant effect is actually the PRF; although it is not completely regular, it is regular for 7 instances until the gap between J and K, after which it repeats. Neither can you calculate the frequency between J and K, and work out an average with that and the PRF. It would make things simple if that was possible but unfortunately it doesn t work like that. So what I can suggest is that you use PRF as the dominating influence at high intensity settings, and change the settings as per the table on page 8, when you wish to apply a signal above 351Hz. The table shows that the lowest PRF is 476Hz, however this is at energy 250, which is too high to cope with, so really the lowest manageable PRF is about 588Hz, at that level you need the energy at 50 which is quite high but not too bad for most. There is another problem however, what about apply a frequency between 351Hz and 588Hz? The new models allow frequency, intensity and gap to be changed together. On the old models if frequency is anything other than default, as soon as intensity is used, the frequency returns to default. Although this is not a major issue, the newer models allow you to achieve the following. To get a frequency up to 372 as defined by gap E to D on the image on page 5, apply the following Int Frequency on device Z F defined by gap E to D You will see that if you increase Z any more Int returns to 1, as the settings are at their limit. I have tried other settings but to no avail, I always get stuck with the limitations of the device. So applying between 372Hz and 588Hz seems not to be possible. I just hope that the other settings are enough to help. Summary Try adding damping as discussed on pages 1-2. As you are familiar with the ZAST procedure using these principles, try the following. To apply a frequency above 351Hz, first apply the values in the small table on this page (above), increase to a comfortable energy level and apply Z2 treatment, if no zeffles are felt after a few minutes, go to the next value. Once completed, return values to default. Then increase the Gap (Z) to 80, increase Int to its maximum, it will be 6 if your default frequency is 90.7Hz or 8 if it is 59.3Hz, the higher the Int the better. Increase to a comfortable energy level and apply Z2 treatment. If no zeffles are felt after a few minutes, reduce Gap to 79, and repeat until you reach Gap =10. As the gap is reduced the pulse repetition frequency is increased.

2 Oscilloscope Familiarization

2 Oscilloscope Familiarization Lab 2 Oscilloscope Familiarization What You Need To Know: Voltages and currents in an electronic circuit as in a CD player, mobile phone or TV set vary in time. Throughout the course you will investigate

More information

Bearing Wear Example #1 Inner Race Fault Alan Friedman DLI Engineering

Bearing Wear Example #1 Inner Race Fault Alan Friedman DLI Engineering Bearing Wear Example #1 Inner Race Fault Alan Friedman DLI Engineering The following spectrum comes from the motor end of a horizontally oriented centrifugal pump. The data was taken in the vertical axis.

More information

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis All circuit simulation packages that use the Pspice engine allow users to do complex analysis that were once impossible to

More information

CH 54 SPECIAL LINES. Ch 54 Special Lines. Introduction

CH 54 SPECIAL LINES. Ch 54 Special Lines. Introduction 479 CH 54 SPECIAL LINES Introduction Y ou may have noticed that all the lines we ve seen so far in this course have had slopes that were either positive or negative. You may also have observed that every

More information

Chapter 4: AC Circuits and Passive Filters

Chapter 4: AC Circuits and Passive Filters Chapter 4: AC Circuits and Passive Filters Learning Objectives: At the end of this topic you will be able to: use V-t, I-t and P-t graphs for resistive loads describe the relationship between rms and peak

More information

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM) ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM) Supplies Needed Motor control board, Transmitter (with good batteries), Receiver Equipment Used Oscilloscope, Function Generator,

More information

LINEAR EQUATIONS IN TWO VARIABLES

LINEAR EQUATIONS IN TWO VARIABLES LINEAR EQUATIONS IN TWO VARIABLES What You Should Learn Use slope to graph linear equations in two " variables. Find the slope of a line given two points on the line. Write linear equations in two variables.

More information

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment:

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment: RUTGERS UNIVERSITY The State University of New Jersey School of Engineering Department Of Electrical and Computer Engineering 332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title:

More information

Class #9: Experiment Diodes Part II: LEDs

Class #9: Experiment Diodes Part II: LEDs Class #9: Experiment Diodes Part II: LEDs Purpose: The objective of this experiment is to become familiar with the properties and uses of LEDs, particularly as a communication device. This is a continuation

More information

CHAPTER 6. Motor Driver

CHAPTER 6. Motor Driver CHAPTER 6 Motor Driver In this lab, we will construct the circuitry that your robot uses to drive its motors. However, before testing the motor circuit we will begin by making sure that you are able to

More information

Exercise 2-1. PAM Signals EXERCISE OBJECTIVE DISCUSSION OUTLINE. Signal sampling DISCUSSION

Exercise 2-1. PAM Signals EXERCISE OBJECTIVE DISCUSSION OUTLINE. Signal sampling DISCUSSION Exercise 2-1 PAM Signals EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the generation of both natural and flat-top sampled PAM signals. You will verify how the frequency

More information

Exercise 2: Hodgkin and Huxley model

Exercise 2: Hodgkin and Huxley model Exercise 2: Hodgkin and Huxley model Expected time: 4.5h To complete this exercise you will need access to MATLAB version 6 or higher (V5.3 also seems to work), and the Hodgkin-Huxley simulator code. At

More information

Evaluating Electrical Events on the Dairy Farm

Evaluating Electrical Events on the Dairy Farm Evaluating Electrical Events on the Dairy Farm What if we had a way to evaluate all the different measurements people make on a dairy farm and we could put this information into a form that the average

More information

The newer Fluke 199C recording scope meters are GREAT instruments if used properly.

The newer Fluke 199C recording scope meters are GREAT instruments if used properly. CowContacttm Volume 2004 Issue I March 2004 www.phasorlabs.com If you use FLUKE ScopeMeters and FlukeView logging software..see CowContact Volume 2G. If you use the Fluke 199C read this FLUKE ScopeMeters

More information

C and solving for C gives 1 C

C and solving for C gives 1 C Physics 241 Lab RLC Radios http://bohr.physics.arizona.edu/~leone/ua/ua_spring_2010/phys241lab.html Name: Section 1: 1. Begin today by reviewing the experimental procedure for finding C, L and resonance.

More information

EE 201 Lab! Tektronix 3021B function generator

EE 201 Lab! Tektronix 3021B function generator EE 201 Lab Tektronix 3021B function generator The function generator produces a time-varying voltage signal at its output terminal. The Tektronix 3021B is capable of producing several standard waveforms

More information

Lecture Notes Intro: Sound Waves:

Lecture Notes Intro: Sound Waves: Lecture Notes (Propertie es & Detection Off Sound Waves) Intro: - sound is very important in our lives today and has been throughout our history; we not only derive useful informationn from sound, but

More information

Notes on OR Data Math Function

Notes on OR Data Math Function A Notes on OR Data Math Function The ORDATA math function can accept as input either unequalized or already equalized data, and produce: RF (input): just a copy of the input waveform. Equalized: If the

More information

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 3157 Electrical Engineering Design II Fall 2013

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 3157 Electrical Engineering Design II Fall 2013 Exercise 1: PWM Modulator University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 3157 Electrical Engineering Design II Fall 2013 Lab 3: Power-System Components and

More information

Statistical Pulse Measurements using USB Power Sensors

Statistical Pulse Measurements using USB Power Sensors Statistical Pulse Measurements using USB Power Sensors Today s modern USB Power Sensors are capable of many advanced power measurements. These Power Sensors are capable of demodulating the signal and processing

More information

1 Simultaneous move games of complete information 1

1 Simultaneous move games of complete information 1 1 Simultaneous move games of complete information 1 One of the most basic types of games is a game between 2 or more players when all players choose strategies simultaneously. While the word simultaneously

More information

Voltage (measured on the vertical axis)

Voltage (measured on the vertical axis) Operate a Digital Storage Oscilloscope Name(s) It is important to understand these basic features of the oscilloscope. VOLTAGE measured on the vertical axis. TIME measured on the horizontal axis. TRIGGER

More information

AE Agricultural Customer Services Play-by-Play Tekscope Manual

AE Agricultural Customer Services Play-by-Play Tekscope Manual 1 2012 AE Agricultural Customer Services Play-by-Play Tekscope Manual TABLE OF CONTENTS I. Definitions II. Waveform Properties 1 III. Scientific Notation... 2 IV. Transient Levels of Concern a. ASAE Paper

More information

SCENAR: the secrets of effectiveness. RITM OKB ZAO, M. Unakafov

SCENAR: the secrets of effectiveness. RITM OKB ZAO, M. Unakafov SCENAR: the secrets of effectiveness RITM OKB ZAO, M. Unakafov A few words about electrotreatment Galvanization is low-strength (under 50mA) and lowvoltage (30-80V) direct current. Galvanization exists

More information

Oscilloscope Measurements

Oscilloscope Measurements PC1143 Physics III Oscilloscope Measurements 1 Purpose Investigate the fundamental principles and practical operation of the oscilloscope using signals from a signal generator. Measure sine and other waveform

More information

SAMPLE: EXPERIMENT 2 Series RLC Circuit / Bode Plot

SAMPLE: EXPERIMENT 2 Series RLC Circuit / Bode Plot SAMPLE: EXPERIMENT 2 Series RLC Circuit / Bode Plot ---------------------------------------------------------------------------------------------------- This experiment is an excerpt from: Electric Experiments

More information

Yet More On Decoupling, Part 2: ring the changes, change the rings Kendall Castor-Perry

Yet More On Decoupling, Part 2: ring the changes, change the rings Kendall Castor-Perry Page 1 of 9 Yet More On Decoupling, Part 2: ring the changes, change the rings Kendall Castor-Perry This article was published on EDN: http://www.edn.com/design/powermanagement/4412870/why-bypass-caps-make-a-difference---part-2--power-supplyexcitation-and-ringing

More information

Department of Electrical & Computer Engineering Technology. EET 3086C Circuit Analysis Laboratory Experiments. Masood Ejaz

Department of Electrical & Computer Engineering Technology. EET 3086C Circuit Analysis Laboratory Experiments. Masood Ejaz Department of Electrical & Computer Engineering Technology EET 3086C Circuit Analysis Laboratory Experiments Masood Ejaz Experiment # 1 DC Measurements of a Resistive Circuit and Proof of Thevenin Theorem

More information

PRODUCT DEMODULATION - SYNCHRONOUS & ASYNCHRONOUS

PRODUCT DEMODULATION - SYNCHRONOUS & ASYNCHRONOUS PRODUCT DEMODULATION - SYNCHRONOUS & ASYNCHRONOUS INTRODUCTION...98 frequency translation...98 the process...98 interpretation...99 the demodulator...100 synchronous operation: ω 0 = ω 1...100 carrier

More information

3A: PROPERTIES OF WAVES

3A: PROPERTIES OF WAVES 3A: PROPERTIES OF WAVES Int roduct ion Your ear is complicated device that is designed to detect variations in the pressure of the air at your eardrum. The reason this is so useful is that disturbances

More information

EE283 Electrical Measurement Laboratory Laboratory Exercise #7: Digital Counter

EE283 Electrical Measurement Laboratory Laboratory Exercise #7: Digital Counter EE283 Electrical Measurement Laboratory Laboratory Exercise #7: al Counter Objectives: 1. To familiarize students with sequential digital circuits. 2. To show how digital devices can be used for measurement

More information

Lab M6: The Doppler Effect

Lab M6: The Doppler Effect M6.1 Lab M6: The Doppler Effect Introduction The purpose in this lab is to teach the basic properties of waves (amplitude, frequency, wavelength, and speed) using the Doppler effect. This effect causes

More information

EENG-201 Experiment # 4: Function Generator, Oscilloscope

EENG-201 Experiment # 4: Function Generator, Oscilloscope EENG-201 Experiment # 4: Function Generator, Oscilloscope I. Objectives Upon completion of this experiment, the student should be able to 1. To become familiar with the use of a function generator. 2.

More information

BASIC ELECTRONICS PROF. T.S. NATARAJAN DEPT OF PHYSICS IIT MADRAS

BASIC ELECTRONICS PROF. T.S. NATARAJAN DEPT OF PHYSICS IIT MADRAS BASIC ELECTRONICS PROF. T.S. NATARAJAN DEPT OF PHYSICS IIT MADRAS LECTURE-12 TRANSISTOR BIASING Emitter Current Bias Thermal Stability (RC Coupled Amplifier) Hello everybody! In our series of lectures

More information

Class #3: Experiment Signals, Instrumentation, and Basic Circuits

Class #3: Experiment Signals, Instrumentation, and Basic Circuits Class #3: Experiment Signals, Instrumentation, and Basic Circuits Purpose: The objectives of this experiment are to gain some experience with the tools we use (i.e. the electronic test and measuring equipment

More information

INTRODUCTION TO AC FILTERS AND RESONANCE

INTRODUCTION TO AC FILTERS AND RESONANCE AC Filters & Resonance 167 Name Date Partners INTRODUCTION TO AC FILTERS AND RESONANCE OBJECTIVES To understand the design of capacitive and inductive filters To understand resonance in circuits driven

More information

Waveform Generators and Oscilloscopes. Lab 6

Waveform Generators and Oscilloscopes. Lab 6 Waveform Generators and Oscilloscopes Lab 6 1 Equipment List WFG TEK DPO 4032A (or MDO3012) Resistors: 10kΩ, 1kΩ Capacitors: 0.01uF 2 Waveform Generators (WFG) The WFG supplies a variety of timevarying

More information

NOTES ON A DERIVED NEGATIVE SUPPLY

NOTES ON A DERIVED NEGATIVE SUPPLY ELECTRONOTES WEBNOTE 10/15/2012 ENWN7 NOTES ON A DERIVED NEGATIVE SUPPLY Recently my attention came back to an old app note: An Op-Amp Supply Based on a 12.6V Filament Transformer, AN-136, June 15, 1979.

More information

Course materials and schedule are at. positron.hep.upenn.edu/p364

Course materials and schedule are at. positron.hep.upenn.edu/p364 Physics 364, Fall 2014, Lab #4 Name: (RC circuits low-pass & high-pass filters, integrator, differentiator ) Wednesday, September 10 (section 401); Thursday, September 11 (section 402) Course materials

More information

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE 159 Name Date Partners Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE OBJECTIVES To understand the design of capacitive and inductive filters To understand resonance in circuits driven by AC signals

More information

Agilent 33220A Function Generator Tutorial

Agilent 33220A Function Generator Tutorial Contents UNIVERSITY OF CALIFORNIA AT BERKELEY College of Engineering Department of Electrical Engineering and Computer Sciences EE105 Lab Experiments Agilent 33220A Function Generator Tutorial 1 Introduction

More information

6.1 Slope of a Line Name: Date: Goal: Determine the slope of a line segment and a line.

6.1 Slope of a Line Name: Date: Goal: Determine the slope of a line segment and a line. 6.1 Slope of a Line Name: Date: Goal: Determine the slope of a line segment and a line. Toolkit: - Rate of change - Simplifying fractions Main Ideas: Definitions Rise: the vertical distance between two

More information

Lab 2: Capacitors. Integrator and Differentiator Circuits

Lab 2: Capacitors. Integrator and Differentiator Circuits Lab 2: Capacitors Topics: Differentiator Integrator Low-Pass Filter High-Pass Filter Band-Pass Filter Integrator and Differentiator Circuits The simple RC circuits that you built in a previous section

More information

Experiment 5.A. Basic Wireless Control. ECEN 2270 Electronics Design Laboratory 1

Experiment 5.A. Basic Wireless Control. ECEN 2270 Electronics Design Laboratory 1 .A Basic Wireless Control ECEN 2270 Electronics Design Laboratory 1 Procedures 5.A.0 5.A.1 5.A.2 5.A.3 5.A.4 5.A.5 5.A.6 Turn in your pre lab before doing anything else. Receiver design band pass filter

More information

Economics 101 Spring 2015 Answers to Homework #1 Due Thursday, February 5, 2015

Economics 101 Spring 2015 Answers to Homework #1 Due Thursday, February 5, 2015 Economics 101 Spring 2015 Answers to Homework #1 Due Thursday, February 5, 2015 Directions: The homework will be collected in a box before the lecture. Please place your name on top of the homework (legibly).

More information

Lab 1: Basic Lab Equipment and Measurements

Lab 1: Basic Lab Equipment and Measurements Abstract: Lab 1: Basic Lab Equipment and Measurements This lab exercise introduces the basic measurement instruments that will be used throughout the course. These instruments include multimeters, oscilloscopes,

More information

Class #7: Experiment L & C Circuits: Filters and Energy Revisited

Class #7: Experiment L & C Circuits: Filters and Energy Revisited Class #7: Experiment L & C Circuits: Filters and Energy Revisited In this experiment you will revisit the voltage oscillations of a simple LC circuit. Then you will address circuits made by combining resistors

More information

Chapter 8. Representing Multimedia Digitally

Chapter 8. Representing Multimedia Digitally Chapter 8 Representing Multimedia Digitally Learning Objectives Explain how RGB color is represented in bytes Explain the difference between bits and binary numbers Change an RGB color by binary addition

More information

Exercise 1: AC Waveform Generator Familiarization

Exercise 1: AC Waveform Generator Familiarization Exercise 1: AC Waveform Generator Familiarization EXERCISE OBJECTIVE When you have completed this exercise, you will be able to operate an ac waveform generator by using equipment provided. You will verify

More information

Robert B.Hallock Draft revised April 11, 2006 finalpaper2.doc

Robert B.Hallock Draft revised April 11, 2006 finalpaper2.doc How to Optimize the Sharpness of Your Photographic Prints: Part II - Practical Limits to Sharpness in Photography and a Useful Chart to Deteremine the Optimal f-stop. Robert B.Hallock hallock@physics.umass.edu

More information

Chapter 17 Waves in Two and Three Dimensions

Chapter 17 Waves in Two and Three Dimensions Chapter 17 Waves in Two and Three Dimensions Slide 17-1 Chapter 17: Waves in Two and Three Dimensions Concepts Slide 17-2 Section 17.1: Wavefronts The figure shows cutaway views of a periodic surface wave

More information

How to source exponential waveform

How to source exponential waveform How to source exponential waveform This material shows how to source exponential waveform using an example to source it to 1 kohm resistor. Figure 1 illustrates the connection and condition supposed in

More information

SolidWorks Tutorial 1. Axis

SolidWorks Tutorial 1. Axis SolidWorks Tutorial 1 Axis Axis This first exercise provides an introduction to SolidWorks software. First, we will design and draw a simple part: an axis with different diameters. You will learn how to

More information

AC CURRENTS, VOLTAGES, FILTERS, and RESONANCE

AC CURRENTS, VOLTAGES, FILTERS, and RESONANCE July 22, 2008 AC Currents, Voltages, Filters, Resonance 1 Name Date Partners AC CURRENTS, VOLTAGES, FILTERS, and RESONANCE V(volts) t(s) OBJECTIVES To understand the meanings of amplitude, frequency, phase,

More information

BME/ISE 3511 Laboratory One - Laboratory Equipment for Measurement. Introduction to biomedical electronic laboratory instrumentation and measurements.

BME/ISE 3511 Laboratory One - Laboratory Equipment for Measurement. Introduction to biomedical electronic laboratory instrumentation and measurements. BME/ISE 3511 Laboratory One - Laboratory Equipment for Measurement Learning Objectives: Introduction to biomedical electronic laboratory instrumentation and measurements. Supplies and Components: Breadboard

More information

Lab 4: Using the CODEC

Lab 4: Using the CODEC Lab 4: Using the CODEC ECE 2060 Spring, 2016 Haocheng Zhu Gregory Ochs Monday 12:40 15:40 Date of Experiment: 03/28/16 Date of Submission: 04/08/16 Abstract This lab covers the use of the CODEC that is

More information

Velleman Arbitrary Function Generator: Windows 7 by Mr. David Fritz

Velleman Arbitrary Function Generator: Windows 7 by Mr. David Fritz Velleman Arbitrary Function Generator: Windows 7 by Mr. David Fritz You should already have the drivers installed Launch the scope control software. Start > Programs > Velleman > PcLab2000LT What if the

More information

Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers

Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers White Paper Abstract This paper presents advances in the instrumentation techniques that can be used for the measurement and

More information

How to get more quality clients to your law firm

How to get more quality clients to your law firm How to get more quality clients to your law firm Colin Ritchie, Business Coach for Law Firms Tory Ishigaki: Hi and welcome to the InfoTrack Podcast, I m your host Tory Ishigaki and today I m sitting down

More information

How to Build a Can Rotation System

How to Build a Can Rotation System The Only Disclaimer That You Might Actually Read because it s probably the shortest. When you use woodworking tools, sharp object, drills, nails, screwdrivers, etc., accidents can happen. The author of

More information

Sonoma State University Department of Engineering Science Spring 2017

Sonoma State University Department of Engineering Science Spring 2017 EE 110 Introduction to Engineering & Laboratory Experience Saeid Rahimi, Ph.D. Lab 4 Introduction to AC Measurements (I) AC signals, Function Generators and Oscilloscopes Function Generator (AC) Battery

More information

TIMS: Introduction to the Instrument

TIMS: Introduction to the Instrument TIMS: Introduction to the Instrument Modules: Audio Oscillator, Speech, Adder, Wideband True RMS Meter, Digital Utilities 1 Displaying a Signal on the PicoScope 1. Turn on TIMS. 2. Computer: Start > All

More information

Designing Your Own Amplifier, Part 1: Voltage Amplifier Stages

Designing Your Own Amplifier, Part 1: Voltage Amplifier Stages Audio Classroom Designing Your Own Amplifier, Part 1: Voltage Amplifier Stages This article appeared originally in Audiocraft, March 1956. 1956 by Audiocom, Inc. BY NORMAN H. CROWHURST How, do you go about

More information

Sampling and Reconstruction

Sampling and Reconstruction Experiment 10 Sampling and Reconstruction In this experiment we shall learn how an analog signal can be sampled in the time domain and then how the same samples can be used to reconstruct the original

More information

Sound Waves and Beats

Sound Waves and Beats Sound Waves and Beats Computer 32 Sound waves consist of a series of air pressure variations. A Microphone diaphragm records these variations by moving in response to the pressure changes. The diaphragm

More information

Lab 1B LabVIEW Filter Signal

Lab 1B LabVIEW Filter Signal Lab 1B LabVIEW Filter Signal Due Thursday, September 12, 2013 Submit Responses to Questions (Hardcopy) Equipment: LabVIEW Setup: Open LabVIEW Skills learned: Create a low- pass filter using LabVIEW and

More information

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation EECE208 INTRO To ELECTRICAL ENG LAB Dr. Charles Kim LAB 2. Instrumentation Objectives A brief description of the equipment (Oscilloscope, Function Generator, Power Supply, and Digital Multimeter) and its

More information

Lecture 21. Single-phase SPWM inverter switching schemes

Lecture 21. Single-phase SPWM inverter switching schemes Lecture 21. Single-phase SPWM inverter switching schemes 21.1 Single-phase SPWM Inverter with Unipolar Switching Scheme In this scheme, switches T1 and T2 or T3 and T4 are not switched on together. Instead,

More information

Physics 262. Lab #1: Lock-In Amplifier. John Yamrick

Physics 262. Lab #1: Lock-In Amplifier. John Yamrick Physics 262 Lab #1: Lock-In Amplifier John Yamrick Abstract This lab studied the workings of a photodiode and lock-in amplifier. The linearity and frequency response of the photodiode were examined. Introduction

More information

Loudspeaker Array Case Study

Loudspeaker Array Case Study Loudspeaker Array Case Study The need for intelligibility Churches, theatres and schools are the most demanding applications for speech intelligibility. The whole point of being in these facilities is

More information

OSCILLOSCOPES, MULTIMETERS, & STRAIN GAGES

OSCILLOSCOPES, MULTIMETERS, & STRAIN GAGES Community College of Allegheny County Unit 1 Page 1 OSCILLOSCOPES, MULTIMETERS, & STRAIN GAGES The Overweight Sub That Cost Billions: After Spain invested $2.7 billion in a program for diesel-electric

More information

Lab 04. Basic Oscilloscope Operation Capacitor Time Constant. 1. The Oscilloscope.

Lab 04. Basic Oscilloscope Operation Capacitor Time Constant. 1. The Oscilloscope. Lab 04 Basic Oscilloscope Operation Capacitor Time Constant Sierra College CIE-01 Jim Weir 530.272.2203 jweir43@gmail.com www.rstengineering.com/sierra. 1. The Oscilloscope. a. As you can see from the

More information

TECHNICAL REPORT: CVEL INVESTIGATION OF AM RADIO INTERFERENCE IN A TRACTOR. Hua Zeng, Haixin Ke, and Todd Hubing. Clemson University

TECHNICAL REPORT: CVEL INVESTIGATION OF AM RADIO INTERFERENCE IN A TRACTOR. Hua Zeng, Haixin Ke, and Todd Hubing. Clemson University TECHNICAL REPORT: CVEL-7 INVESTIGATION OF AM RADIO INTERFERENCE IN A TRACTOR Hua Zeng, Haixin Ke, and Todd Hubing Clemson University September 7, 7 EXECUTIVE SUMMARY This report describes and evaluates

More information

BOB s 5 PHASES of DEFENSE AT DUPLICATE

BOB s 5 PHASES of DEFENSE AT DUPLICATE Bob s overview of Defense at Duplicate is composed of two Parts: This Part I is an overview of the process of playing a hand at duplicate. It is a presentation of an overall way of defending every hand

More information

Basic Electronics Learning by doing Prof. T.S. Natarajan Department of Physics Indian Institute of Technology, Madras

Basic Electronics Learning by doing Prof. T.S. Natarajan Department of Physics Indian Institute of Technology, Madras Basic Electronics Learning by doing Prof. T.S. Natarajan Department of Physics Indian Institute of Technology, Madras Lecture 38 Unit junction Transistor (UJT) (Characteristics, UJT Relaxation oscillator,

More information

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization The University of Jordan Mechatronics Engineering Department Electronics Lab.(0908322) Experiment 1: Lab Equipment Familiarization Objectives To be familiar with the main blocks of the oscilloscope and

More information

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab University of Jordan School of Engineering Electrical Engineering Department EE 204 Electrical Engineering Lab EXPERIMENT 1 MEASUREMENT DEVICES Prepared by: Prof. Mohammed Hawa EXPERIMENT 1 MEASUREMENT

More information

I. Introduction to Animal Sensitivity and Response

I. Introduction to Animal Sensitivity and Response Stray Voltage Field Guide Douglas J. Reinemann, Ph.D. Professor of Biological Systems Engineering University of Wisconsin Madison September 2007 Update I. Introduction to Animal Sensitivity and Response

More information

Mr. Pulsartm. Specialized Function Generator

Mr. Pulsartm. Specialized Function Generator Mr. Pulsartm Specialized Function Generator Getting Started: Turn the unit ON with the slide switch on the left side of the unit. The unit will stay on as long as you like, but leaving the unit powered

More information

Pre- and Post Ringing Of Impulse Response

Pre- and Post Ringing Of Impulse Response Pre- and Post Ringing Of Impulse Response Source: http://zone.ni.com/reference/en-xx/help/373398b-01/svaconcepts/svtimemask/ Time (Temporal) Masking.Simultaneous masking describes the effect when the masked

More information

Marvelmind Indoor Navigation System Operating Manual V2015_09_21

Marvelmind Indoor Navigation System Operating Manual V2015_09_21 Marvelmind Indoor Navigation System Operating Manual V2015_09_21 Table of Contents 1) Executive summary...3 2) Basics of the system...4 3) What is in the box...8 4) Technical Specifications...9 Table:

More information

Notes on Experiment #1

Notes on Experiment #1 Notes on Experiment #1 Bring graph paper (cm cm is best) From this week on, be sure to print a copy of each experiment and bring it with you to lab. There will not be any experiment copies available in

More information

Learning Objectives:

Learning Objectives: Learning Objectives: At the end of this topic you will be able to; recall the conditions for maximum voltage transfer between sub-systems; analyse a unity gain op-amp voltage follower, used in impedance

More information

Receiver Architectures

Receiver Architectures Receiver Architectures Modules: VCO (2), Quadrature Utilities (2), Utilities, Adder, Multiplier, Phase Shifter (2), Tuneable LPF (2), 100-kHz Channel Filters, Audio Oscillator, Noise Generator, Speech,

More information

LAB #7: Digital Signal Processing

LAB #7: Digital Signal Processing LAB #7: Digital Signal Processing Equipment: Pentium PC with NI PCI-MIO-16E-4 data-acquisition board NI BNC 2120 Accessory Box VirtualBench Instrument Library version 2.6 Function Generator (Tektronix

More information

Speed of Light in Air

Speed of Light in Air Speed of Light in Air Introduction Light can travel a distance comparable to seven and one-half times around the Earth in one second. The first accurate measurements of the speed of light were performed

More information

transformer rectifiers

transformer rectifiers Power supply mini-project This week, we finish up 201 lab with a short mini-project. We will build a bipolar power supply and use it to power a simple amplifier circuit. 1. power supply block diagram Figure

More information

Module 3 : Sampling and Reconstruction Problem Set 3

Module 3 : Sampling and Reconstruction Problem Set 3 Module 3 : Sampling and Reconstruction Problem Set 3 Problem 1 Shown in figure below is a system in which the sampling signal is an impulse train with alternating sign. The sampling signal p(t), the Fourier

More information

Experiment Five: The Noisy Channel Model

Experiment Five: The Noisy Channel Model Experiment Five: The Noisy Channel Model Modified from original TIMS Manual experiment by Mr. Faisel Tubbal. Objectives 1) Study and understand the use of marco CHANNEL MODEL module to generate and add

More information

Chapter 2: PRESENTING DATA GRAPHICALLY

Chapter 2: PRESENTING DATA GRAPHICALLY 2. Presenting Data Graphically 13 Chapter 2: PRESENTING DATA GRAPHICALLY A crowd in a little room -- Miss Woodhouse, you have the art of giving pictures in a few words. -- Emma 2.1 INTRODUCTION Draw a

More information

General Construction & Operation of Oscilloscopes

General Construction & Operation of Oscilloscopes Science 14 Lab 2: The Oscilloscope Introduction General Construction & Operation of Oscilloscopes An oscilloscope is a widely used device which uses a beam of high speed electrons (on the order of 10 7

More information

Physics 309 Lab 3 Bipolar junction transistor

Physics 309 Lab 3 Bipolar junction transistor Physics 39 Lab 3 Bipolar junction transistor The purpose of this third lab is to learn the principles of operation of a bipolar junction transistor, how to characterize its performances, and how to use

More information

4.4 Slope and Graphs of Linear Equations. Copyright Cengage Learning. All rights reserved.

4.4 Slope and Graphs of Linear Equations. Copyright Cengage Learning. All rights reserved. 4.4 Slope and Graphs of Linear Equations Copyright Cengage Learning. All rights reserved. 1 What You Will Learn Determine the slope of a line through two points Write linear equations in slope-intercept

More information

Experiment 5 The Oscilloscope

Experiment 5 The Oscilloscope Experiment 5 The Oscilloscope Vision is the art of seeing things invisible. J. Swift (1667-1745) OBJECTIVE To learn to operate a cathode ray oscilloscope. THEORY The oscilloscope, or scope for short, is

More information

Chapter 2. Meeting 2, Measures and Visualizations of Sounds and Signals

Chapter 2. Meeting 2, Measures and Visualizations of Sounds and Signals Chapter 2. Meeting 2, Measures and Visualizations of Sounds and Signals 2.1. Announcements Be sure to completely read the syllabus Recording opportunities for small ensembles Due Wednesday, 15 February:

More information

Introduction to Equalization

Introduction to Equalization Introduction to Equalization Tools Needed: Real Time Analyzer, Pink noise audio source The first thing we need to understand is that everything we hear whether it is musical instruments, a person s voice

More information

Using Voltage Dividers to Design a Photo-Sensitive LED Circuit. ( Doug Oliver & Jackie Kane. May be reproduced for non-profit classroom use.

Using Voltage Dividers to Design a Photo-Sensitive LED Circuit. ( Doug Oliver & Jackie Kane. May be reproduced for non-profit classroom use. Using Voltage Dividers to Design a Photo-Sensitive LED Circuit ( 2009 - Doug Oliver & Jackie Kane. May be reproduced for non-profit classroom use.) Purpose: After completing the module students will: 1.

More information

EC310 Security Exercise 20

EC310 Security Exercise 20 EC310 Security Exercise 20 Introduction to Sinusoidal Signals This lab demonstrates a sinusoidal signal as described in class. In this lab you will identify the different waveform parameters for a pure

More information

Lab 13 AC Circuit Measurements

Lab 13 AC Circuit Measurements Lab 13 AC Circuit Measurements Objectives concepts 1. what is impedance, really? 2. function generator and oscilloscope 3. RMS vs magnitude vs Peak-to-Peak voltage 4. phase between sinusoids skills 1.

More information

(Notice that the mean doesn t have to be a whole number and isn t normally part of the original set of data.)

(Notice that the mean doesn t have to be a whole number and isn t normally part of the original set of data.) One-Variable Statistics Descriptive statistics that analyze one characteristic of one sample Where s the middle? How spread out is it? Where do different pieces of data compare? To find 1-variable statistics

More information