1 Bulletin 700-HX Multifunction Digital Timing Relay Model Operating Mode Timing Range Socket Type Contact Output No. of Pins Input Voltage Cat. No. Cat. No. 700 HX A mode: Signal ON-Delay 1 A-1 mode: Signal ON-Delay 2 A-2 mode: Power ON-Delay 1 A-3 mode: Power On-Delay 2 B mode: Repeat Cycle 1 B-1 mode: Repeat Cycle 2 D mode: Signal OFF-delay E mode: One Shot F mode: Cumulative Z mode: On/Off duty adjustable repeat cycle S mode:stop watch toff: Flicker OFF start 1 ton: Flicker ON start 1 toff-1: Flicker OFF start 2 ton-1: Flicker ON start s s s s min 59 s min min hr 59 min hr hr 700-HN HN125 SPDT V AC 700-HX86SA17 24V AC 12 24V DC 700-HX86SU24 General Timer Functions

2 Electrical Ratings Pilot Duty Rating Rated supply voltage Operating voltage range NEMA B to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible ripple: 20%(p-p) max.) % of rated supply voltage Power consumption V AC 4.3VA 24V AC/12 24V DC 3.4VA/1.7 W Inrush Current V AC 3 A 24V AC/12 24V DC 120V AC 5 A 30 A Make 240V AC 15 A 120V AC 3 A Break 240V AC 1.5 A Hp at 120V AC Hp at 240V AC 1/4 Hp 1/3 Hp Mechanical Mounting Method Display Digits Flush mounting, surface mounting, DIN mounting Seven-segment, negative transmissive LCD; Present value (red, 12 mm high characters); Set value (green, 6 mm high characters) Four digits Timer Time ranges s, s, s, s, 0 min 00 s 99 min 59 s, min, 0 hr 00 min 99 hr 59 min, 0.0 hr hr, 0 hr 9999 hr Timer modes Output modes Elapsed time (Up), remaining time (Down), selectable A, A-1, A-2, A-3, B, B-1, D, E, F, Z, S, toff, ton, toff-1, or ton-1 Inputs Input signals Start, reset Input method Start, reset, gate Power reset No-voltage input via:npn transistor or switching of contact Minimum input signal width: 1 or 20 ms (selectable) Minimum power-opening time: 0.5 s (Except for A-3, B-1, and F mode) Control output External Power Supply Key Protect Memory Backup Accuracy of Operating Time and Setting Error SPDT contact output: 5 A at 250V AC, resistive load (cosine=1) Minimum applied load: 10 ma at 5 V DC (failure level: P, reference value) No Yes EEP-ROM (overwritten times min), which can store data for 10 years min. Power-ON start: % +-50 ms max. * to be rated against set value Signal start: % +-30 ms max. * to be rated against set value Signal start at transistor output model: % + 3 ms max. If the set value is within the sensor waiting time (250 ms max.) The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.

3 Characteristics Insulation Resistance 100 mw min. (at 500V DC) Dielectric Strength 2000V AC, 50/60Hz for 1 min between current-carrying terminals and non-current-carrying metal parts (1000V AC for 24V AC/12 to 24V DC type), 1000 VAC, 50/60 Hz for 1 min between non-continuous contacts Noise Immunity Static Immunity Vibration Resistance Shock Resistance Life Expectancy Malfunction Malfunction Mechanical Electrical '+-1.5 kv (between power terminals) for 100 to 240 VAC, +-480V for 24VAC/12 to 24VDC, and +-600V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 ms, 1-ns rise) ±8 kv (malfunction), ±15 kv (destruction) Hz with 0.35 mm single amplitude each in three directions for 10 min 98 m/s2 (approx. 10 G) each in three directions 10 million operations min. (under no load at operation/hr) operations min. (5 A at 250V AC, resistive load at 1800 operation/hr) EMC (EMI) EN Enclosure Ratings Weight Certifications Emission Enclosure: Emission AC mains: (EMS) Immunity ESD: Immunity RFinterference: EN55011 Group1 class A EN55011 Group1 class A EN EN : 4 kv contact discharge (level2) 8 kv air discharge (level3) EN : 10 V/m Panel surface:ip66 and NEMA Type 4X (indoors) Approx. 100 g CE Certified; curus (File No. E14843, Guide NRNTZ/NRNT8), C-Tick Marked Standards EN , EN 61326, VDE0106/P 100, CSA C22.2 No. 14, UL HX User Manual, pub. number 700 UM002_ EN D, available at Literature Library. An attached waterproof packing is necessary to ensure IP66 waterproofing between the 700 HX and installation pan. Timing Charts

4 Output Mode A Mode: Signal ON-Delay (Timer resets when power comes ON.) Output Mode A-1: Signal ON-Delay 2 (Timer resets when power comes ON.) Output Mode A-2: Power ON Delay 1 (Timer resets when power comes ON) Output Mode A-3 Power ON Delay 2 (Timer does not reset when power comes ON) Gate not included on any mode of this relay.

5 Output Mode B: Repeat Cycle (Timer resets when power comes ON.) Output Mode B-1: Repeat Cycle 2 (Timer does not reset when power comes ON) Gate not included on any mode of this relay.

6 Output Mode D: Signal OFF-Delay (Timer resets when power comes ON.) Output Mode E: Interval (Timer resets when power comes ON.) Output Mode F: Cumulative (Timer does not reset when power comes ON) Gate not included on any mode of this relay. Z Mode Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value. The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). When the cycle time is 0, the output will always be OFF. When the cycle time is not 0 and when ON duty has been set to 0 (%), the output will always be OFF. When ON duty has been set to 100 (%), the output will always be ON.

7 Z mode: ON/OFF-duty Adjustable Repeat Cycle Output Mode S: Stop Watch (Timer resets when power comes ON) Output Mode T OFF: Twin Timer OFF start Gate not included on any mode of this Relay.

8 Output Mode T ON: Twin Timer ON start Output Mode TOFF-1: Flicker OFF start 2 (Timer does not reset when power comes ON) Output Mode TON-1: Flicker ON start 2 (Timer does not reset when power comes ON) Gate not included on any mode of this Relay. Copyright 2015 Rockwell Automation, Inc. All Rights Reserved.

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer OMRON Analog Set Multifunction Timers Series To view data sheets, click on any link below: - Standard Timer -G - Star-Delta Timer -F - Twin Timer -H - Power OFF- Delay Timer Multifunction Timer Analog

More information

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start Bulletin -HR Plug-in iming Relays Product election/catalog Number Explanation Bulletin ON-Delay iming Relays ocket or Panel Mounted iming Range From. s h -pin base for socket cat. nos. -HN, -HN, -HN rigger:

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS Timers DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_4_1 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0

More information

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

02/11/2015

02/11/2015 17.5 mm - 1 Relay 5A EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer

More information

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web:  - Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with

More information

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output

More information

Multi-voltage Multi-function. Wiring diagram (without control signal)

Multi-voltage Multi-function. Wiring diagram (without control signal) 80 Modular timers 16 A 80 Multi-function and mono-function timer range 80.01T - Multi-function & multi-voltage 80.11T - On-delay, multi-voltage Complies with EN 45545-2:2013 (protection against fire of

More information

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6). Power PCB Relay Subminiature 20 L x 9.90 W x 9.90 H mm (0.79 L x 0.39 W x 0.39 H in) Low power consumption (200 mw) Sealed construction permits automatic soldering and cleaning of the PC board High-capacity

More information

Model Number Structure

Model Number Structure Solid-state Twin Timers H3CR-F DIN 48 48-mm Twin Timers Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. - and -times can be set independently and so combinations of long - or

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

Multifunctional counter tico 772/773/774

Multifunctional counter tico 772/773/774 Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

05/09/2014

05/09/2014 48 x 48 Digital LCD Timer 814 Part number 88857005 Relay output digital timers LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in

More information

em4 local - Robust Specific characteristics Part number

em4 local - Robust Specific characteristics Part number em4 em4 local em4 local Very compact and easy to program nanoplc Save time in designing your application using the most intuitive graphical function block language of the market Measure accurately your

More information

Analog Timer TTL Series

Analog Timer TTL Series Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product

More information

Self-Powered Counters H7ET

Self-Powered Counters H7ET Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit

More information

83 Series - Modular timers 16 A. Features

83 Series - Modular timers 16 A. Features Features 83 Series - Modular timers 16 A 83.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 83.11 - delay, multi-voltage 22.5 mm wide Six time scales from 0.1s to 20h High

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital

More information

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min Weekly Time Switch H5S Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

Song Chuan / Relay Catalog 507

Song Chuan / Relay Catalog 507 07 eatures High rating miniature PCB Relay. AC & DC coil are both available. UL/CUL and VDE approved. 7A 277VAC SPDT. 2A 277VAC DPDT. Low profile.7 and high insulation system class High CTI material &

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

SPECIFICATIONS. Input Output Approvals

SPECIFICATIONS. Input Output Approvals Technical Data Sheet 172 Watt 15 Volt, Single Output, High V. Output Power Supply with PFC for LEDs UNIT CODE LED-HLG 185H-15 DESCRIPTION 172 Watt, Volt, Single Output, Waterproof, LED Power Supply with

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01 Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types, TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relays Detect when all 3 phases are present and have the

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC Product data sheet Characteristics RE11RMMU time delay relay 10 functions - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Width pitch dimension Control type Voltage range Connections

More information

Universal Voltage Cabled Photoelectric E3JK

Universal Voltage Cabled Photoelectric E3JK Universal Voltage Cabled Photoelectric Small Cable Sensor with Complementary Outputs Universal AC/DC supply voltage Relay or NPN/PNP transistor output, light-on or dark-on operation Polarized retroreflective

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

E E E E E E E E E E E IP65 IP67

E E E E E E E E E E E IP65 IP67 .. 240W Single Output Switching Power Supply ½ IP65 IP67 SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RATED CURRENT RATED POWER RIPPLE & NOISE (max.) Note.2

More information

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC 10KV Lightning Surge Protection Smart Over-Temperature Protection Universal AC Input up to 305Vac High Efficiency (Up to 92%) Active Power Factor Correction Constant Current With Dimming Options Waterproof

More information

Energy Management Energy Meter Type EM340

Energy Management Energy Meter Type EM340 Energy Management Energy Meter Type EM340 Digital input (for tariff management Easy connection or wrong current direction detection Certified according to MID Directive (option PF only: see how to order

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross)

More information

1715 Redundant I/O System Specifications

1715 Redundant I/O System Specifications Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS-(S) Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393

More information

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2 Miniature Relay for Signal Circuits ROHS compliant. Wide switching power of 10 µa to 2 A. High dielectric strength coil-contacts:1,000 VAC; open contacts: 750 VAC. Conforms to FCC Part 68 requirements.

More information

IP65 IP67. ±5% 0.5Vp-p. 750ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load

IP65 IP67. ±5% 0.5Vp-p. 750ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load IP65 IP67 SPECIFICATION MODEL 350 700 RATED CURRENT 350mA 700mA CURRENT ACCURACY ±5.0% CONSTANT CURRENT REGION Note.6 100 ~ 0V 50 ~ 100V RATED POWER 70W 70W OUTPUT RIPPLE CURRENT RIPPLE & NOISE ±5% Note.7

More information

24V 14.4 ~ 24V 20V 12 ~ 20V. 48V 28.8 ~ 48V 3.33A 2.67A 2A 1.67A 1.34A 1.12A 0.96A 0.84A 39.96W 40.05W 40W 40.08W 40.2W 40.32W 40.32W 40.

24V 14.4 ~ 24V 20V 12 ~ 20V. 48V 28.8 ~ 48V 3.33A 2.67A 2A 1.67A 1.34A 1.12A 0.96A 0.84A 39.96W 40.05W 40W 40.08W 40.2W 40.32W 40.32W 40. IP65 IP67 SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE CONSTANT CURRENT REGION Note.4 7.2 ~12V RATED CURRENT RATED POWER RIPPLE & NOISE (max.) Note.2 150mVp-p

More information

Energy Management Energy Analyzer Type EM111

Energy Management Energy Analyzer Type EM111 Energy Management Energy Analyzer Type EM111 Single phase energy analyzer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC Overview/Product Selection Bulletin 700-FS Adjustable Function and Timing Range DIN Rail Mounted without Cost of Socket 22.5 mm Wide Multifunction or Single Functions Available as SPDT or DPDT Contact,

More information

1715 Redundant I/O System Specifications

1715 Redundant I/O System Specifications Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly

More information

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM111 Energy Management Energy Meter Type EM111 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter

More information

Chronos 2 electronic timers - Plug-in 8-pin (35 mm)

Chronos 2 electronic timers - Plug-in 8-pin (35 mm) hronos electronic timers Plugin pin (5 mm) elay output or change over relays Multifunction or monofunction Multirange (7 ranges, available options) Multivoltage elay output or : 50 V (0 A L) Plugin LED

More information

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC) 6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

888-1AC-F-C 888-1AC-F-V 888-1AC-F-S (SPNO) 888-2AC-F-C 888-2AC-F-V 888-2AC-F-S (DPNO) 888N-2AC-F-C 888N-2AC-F-V 888N-2AC-F-S (DPNO)

888-1AC-F-C 888-1AC-F-V 888-1AC-F-S (SPNO) 888-2AC-F-C 888-2AC-F-V 888-2AC-F-S (DPNO) 888N-2AC-F-C 888N-2AC-F-V 888N-2AC-F-S (DPNO) Type List Standard Type eatures High rating miniature PCB Relay. AC & DC coil are both available. UL/CUL and VDE approved. 7A 277VAC SPDT. Low profile.7mm and high insulation system Class. High CTI material

More information

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase True RMS AC/DC Over and Under Current Types DIC0, PIC0 DIC0 PIC0 TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Power Supply for LEDs 480 Watt 12 Volt, Waterproof, Single Output

Power Supply for LEDs 480 Watt 12 Volt, Waterproof, Single Output Technical Data Sheet Power Supply for LEDs 480 Watt 12 Volt, Waterproof, Single Output UNIT CODE HLG600-H 12 DESCRIPTION 480 Watt, 12 Volt, Single Output, Waterproof, LED Power Supply with Adjustable Output

More information

17.5mm Chronos 2 Timers

17.5mm Chronos 2 Timers 7.5mm hronos imers rouzet Products /Automation ontrols /Electronic imers /7.5mm hronos imers POD FEAES Multifunction or monofunction Multirange (7 ranges, available options) SPD relay output: 0A 50V on

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

HLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54 DC VOLTAGE CONSTANT CURRENT REGION Note.

HLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54 DC VOLTAGE CONSTANT CURRENT REGION Note. IP65 IP67 SPECIFICATION MODEL -15 - -24-30 -36-42 -48-54 DC VOLTAGE CONSTANT CURRENT REGION Note.4 15V 9 ~ 15V V 12 ~ V 24V 14.4 ~ 24V 30V 18 ~ 30V 36V 21.6 ~ 36V 42V 25.2 ~ 42V 48V 28.8 ~ 48V 54V.4 ~

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MURc3 Part number 88826503 DIN Rail Mount 17.5 mm MURc3 Part number 88826503 Just one digit differentiates the new range part number from the old range's Previous part number : 88

More information

Flickerless / Dim Power supply

Flickerless / Dim Power supply Model Name : Features : ㅡ Flickerless ㅡ Fullprotection provided: OCP/OVP/OTP/SCP/OLP ㅡ Low Power Dissipation (Standby mode :

More information

Suitable for lighting and motor load, 1 Form A 50A latching relays

Suitable for lighting and motor load, 1 Form A 50A latching relays Suitable for lighting and motor load, 50A latching relays DJ-H RELAYS (ADJH) 9.0 5 1 0.2 9.0 5 New 1 FEATURES 1. High inrush capability Tungsten load (TV-20 class) Electronic ballast load (NEMA10) Capacitive

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications HEC130/150RTN48QSCA A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case with

More information

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Ordering Information. Ratchet Relay G4Q. Model Number Legend Ratchet Relay CSM DS_E_3_2 Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5) 46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

AMIK Three Phase Digital Panel Meters

AMIK Three Phase Digital Panel Meters AMIK Three Phase Digital Panel Meters USA SICE 1936 ELIAILIT EOD MEASUE Special Features 3 Line 4 Digits ultra bright LED Display (up to 9999) On site Programmable CT/PT atios User selectable CT Secondary

More information

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches Weekly Timer Timer Provides Prompted Programming, Flexibility in Programs Within the Week AM/PM display 24 program steps A different program possible each day Over midnight settings possible Two independent

More information

DRIV-ZT-24V-90W LED 0-10V Dimming Driver, Wet Location

DRIV-ZT-24V-90W LED 0-10V Dimming Driver, Wet Location LED 010V Dimming Driver, Wet Location SPECIFICATION OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE RATED CURRENT RATED POWER DIMMING RANGE PWM FREQUENCY (Typ.) VOLTAGE TOLERANCE

More information

Energy Management Energy Analyzer Type EM210

Energy Management Energy Analyzer Type EM210 Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)

More information

AC - DC 96W LED Driver MDC100 Single Output Series

AC - DC 96W LED Driver MDC100 Single Output Series AC - DC LED Driver Features Built-in 10KV lightning surge protection (EN61000-4-5) 90 ~ 305Vac full range input; Active PFC Output voltage range up to 58Vdc for outdoor lighting Aluminum case IP65/ IP67

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

Time relay RXKA 1. (xx jpg) RXKA 1

Time relay RXKA 1. (xx jpg) RXKA 1 Time relay RXKA 1 (xx02000674.jpg) RXKA 1 Features For protection, control, signal and industrial applications On-delay and Off-delay functions Continuous and pulse output functions Setting range 0.1-320

More information

IP65 IP67 6.2A. Can be adjusted by internal potentiometer A type only

IP65 IP67 6.2A. Can be adjusted by internal potentiometer A type only Bauartgepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 00000000 185W Single Output Switching Power Supply Ⅰ IP65 IP67 SPECIFICATION MODEL OUTPUT INPUT OTHERS NOTE - -15 - -24-30 -36-42 -48-54

More information

HEC-45LTN-45PFAS Rev A

HEC-45LTN-45PFAS Rev A A. Features High Efficiency (Up to 85%). Active Power Factor Correction (Typical 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP. Fully isolated plastic case with IP20 and dry location. Class

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

80W Single Output Switching Power Supply

80W Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE CONSTANT CURRENT REGION Note.4 RATED CURRENT RATED POWER RIPPLE & NOISE (max.) Note. 0mVp-p 0mVp-p 0mVp-p 0mVp-p

More information

AC - DC 96W LED Driver MDC100 Single Output Series

AC - DC 96W LED Driver MDC100 Single Output Series Features Built-in 10KV lightning surge protection (EN61000-4-5) 90 ~ 305Vac full range input; Active PFC Output voltage range up to 58Vdc for outdoor lighting Aluminum case IP65/ IP67 waterproof Dual mode

More information

WHEN A PLC IS TOO MUCH, AND SPACE FOR

WHEN A PLC IS TOO MUCH, AND SPACE FOR WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than

More information

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information CB ower Relay Up to 30 A switching capacity in compact package. 2.0 mm cantact gap type available (-1A4-B) Available with quick-connect contact terminals for easy load connecting with either QC or CB coil

More information

24/07/2012

24/07/2012 17.5 mm DIN rail mounting MURc3 Part number 88826503 Relay or solid state output Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version)

More information

Totalizing Counters mini-i

Totalizing Counters mini-i mini-i Type 634/635 Type 634: Counter with high immunity against magnetic interfere Type 635: Counter with high shock stability Miniature size Low power consumption Electrical connections in standard grid

More information

02/11/2015

02/11/2015 Standstill monitoring KSW3-JS Part number 85102331 Function "Stillstand detection without sensors" Independent of rotation direction Security with redundancy and feedback circuit 3 forcibly guided "NO"

More information

KRPA, KRP, KA, KR series

KRPA, KRP, KA, KR series Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

120W Single Output Switching Power Supply IP65 IP67

120W Single Output Switching Power Supply IP65 IP67 B auart g epru ft S icherheit egel ma ge od o s be wac g www. tuv.co m ID 2 00 00 00 00 0 HLG- 120 H series IP65 IP67 SPECIFICATION MODEL -24-48 -54 OUTPUT INPUT DC VOLTAGE 24V 48V 54V CONSTANT CURRENT

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

RoHS APPROVAL SHEET. ituner 12V/5A SERIES NO. (05) EA10523C-120 CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0

RoHS APPROVAL SHEET. ituner 12V/5A SERIES NO. (05) EA10523C-120 CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/5A SERIES NO. (05) EA10523C-120 DATE 2010-06-21 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP