Switches & Pilot Devices

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Switches & Pilot Devices"

Transcription

1 ømm - TW Series features: TW NEMA Switches with snap-on contacts Corrosion resistant octagonal chrome plated locking bezel Snap-on 0A contact blocks Incandescent or LED illumination Slow make, double break, self cleaning contacts Modular construction for maximum flexibility NEMA and IP65 watertight/oiltight panel Available assembled or as sub-components Large M.5 screw terminals with captive sems plate UL Listed File No. E6896 TW Series mm NEMA Pushbuttons CSA Approved File No. L5 IDEC has your mm switching needs covered. Button styles include flush, extended, mushroom, or square and all bodies are crafted from fracture-resistant nylon. All illuminated units feature two lens styles, one that maximizes light dispersion, the other accommodates direct lens engraving. Self cleaning contact mechanisms allow for a wide current rating, 5mA to 0A, which reduces the need for various contact materials. When looking for a mm switch that is durable, easy to use, and versatile, then IDEC s TW series is your solution. File No. DK Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 67

2 ømm - TW Series Circuit Breakers Terminal Blocks Contactors Timers elays & Sockets Signaling Lights Specifications Contact atings Characteristics Conforming to Standards Approvals File No. E6896 File No. L5 Certificate No egistration No: J95580 (E-Stops) egistration No: J95580 (All other switches) egistration No: J95580 (Pilot Lights) perating Temperature Vibration esistance Shock esistance Electric Shock Protection Degree of Protection (conforming to IEC6059) (conforming to NEMA ICS6-0) Mechanical Life Pollution Degree (conforming to IEC6097-) ated perational Characteristics ated Insulation Voltage ated Switching ver-voltage ated Impulse Withstanding Voltage ated Thermal Current Minimum Switching Capacity Contact peration ecommended Terminal Torque External Short-Circuit Protection Applicable Wire Size Contact esistance Contact Gap Electrical eliability Lamp atings Horsepower ating Maximum Inrush Current Contact Material Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Contact Block ated Insulation Voltage ated Continuous Current EN6097-, EN , VDE , UL508, CSA C- No. CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0,, 0, 80, 00/0, 80V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0,, 0, 80, 00/0, 80V) TÜV: pushbuttons and selector switches: A600=P600 (N, NC)/Q600 (N-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0,, 0, 80, 00/0, 80V) peration: 5 to +50 C (without freezing), Storage: 0 to +80 C (without freezing) 5 to 55Hz, 00m/sec (0g) conforming to IEC m/sec (00g) conforming to IEC Class 0 conforming to IEC6056 IP65 from front of the panel; (IP5 for key switches) IP0 (Type HW-F contact block) Type,,,, S,,, 5,, (Type,,, 5,, for key switches) Momentary pushbuttons: 5,000,000 (900 operations per hour) All other switches: 500,000 for switches not using a transformer, for switches using a transformer AC-5: A600 or Ue = 50V, le = A (N, NC, N-EM, NC-LB) DC-: P600 or Ue = 5V, le =.A (N, NC) DC-: Q600 or Ue = 5V, le = 0.9A (N-EM, NC-LB) 600V Less than kv, conforming to IEC6097- kv for contact circuit,.5kv for lamp circuit 0 Amp 5 ma at V AC/DC Slow break NC or slow make N, self-cleaning 0.8 N m (7. in lb.) 0A 50V fuse conforming to IEC6069- Minimum x AWG, max. x AWG or x AWG Initial contact resistance of 50mΩ or less mm (N and NC), mm (N-EM and NC-LB) MTBF < fault for 0 million operation cycles (V DC, 5mA) Incandescent: W LEDs: 6V: 7mA max, /V: ma max, 0/0V: 0mA max / 0V (single-phase, non-reversing motor); 0V ( phase, non-reversing motor) 0 A (0 ms) Silver Contact atings by Utilization Category IEC Type HW-C/HW-F 600V 0A Contact atings by Utilization Category AC-5 (A600) DC- (P600) perational Voltage V 8V 50V 0V 0V 0V perational Current AC50/60Hz DC AC- Control of resistive loads and solid state loads 0A 0A 0A 6A A AC-5 Control of electromagnetic loads (> 7VA) 0A 7A 5A A A DC- Control of resistive loads and solid state loads 8A 5A.A.A DC- Control of electromagnets 5A A.A 0.6A 67

3 ømm - TW Series Function B: Momentary : Maintained K: n/ff Lock Bezel Shape Blank: ctagonal F: Full Shroud G: Mushroom Shroud Q: Square To be used for interpreting part numbers only, not for part number development. Non-Illuminated Pushbuttons (Assembled) Assembled Pushbuttons A B ( ) W 0 ( ) B Button Color B: Black G: Green W: White : ed S: Blue Y: Yellow Terminal Blank: Standard N: Fingersafe (IP0) Contact Arrangement 0: N 0: NC 0: N 0: : N-NC : N- Button Shape : Flush : Extended : Mushroom Head Ø 9mm : Mushroom Head Ø 0mm Series Designation W: TW Series Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 67

4 ømm - TW Series Signaling Lights elays & Sockets Non-Illuminated Pushbuttons Flush Extended ecessed Extended with Full Shroud Non-Illuminated Pushbuttons (Assembled) continued Contacts Momentary Action Maintained Action N NC N-NC N N NC N-NC N N NC N-NC N N NC N-NC N ABW0-j ABW0-j ABW-j ABW0-j ABW0-j ABW0-j ABW0-j ABW-j ABW0-j ABW0-j ABFW0-j ABFW0-j ABFW-j ABFW0-j ABFW0-j ABFW0-j ABFW0-j ABFW-j ABFW0-j ABFW0-j AW0-j AW0-j AW-j AW0-j AW0-j AW0-j AW0-j AW-j AW0-j AW0-j AFW0-j AFW0-j AFW-j AFW0-j AFW0-j AFW0-j AFW0-j AFW-j AFW0-j AFW0-j j Button Color Codes Color Black Green ed Blue Yellow White Code B G S Y W Timers Ø 9mm Mushroom Head Ø 0mm Mushroom Head N NC N-NC N N NC N-NC N ABW-j ABW-j ABW-j ABW-j ABW-j ABW0-j ABW0-j ABW-j ABW0-j ABW0-j AW-j AW-j AW-j AW-j AW-j AW0-j AW0-j AW-j AW0-j AW0-j Contactors Ø 0mm Mushroom Head with Full Shroud Square Flush N NC N-NC N N NC N-NC N ABGW0-j ABGW0-j ABGW-j ABGW0-j ABGW0-j ABQW0-j ABQW0-j ABQW-j ABQW0-j ABQW0-j AGW0-j AGW0-j AGW-j AGW0-j AGW0-j AQW0-j AQW0-j AQW-j AQW0-j AQW0-j Terminal Blocks Square Extended N NC N-NC N ABQW0-j ABQW0-j ABQW-j ABQW0-j ABQW0-j AQW0-j AQW0-j AQW-j AQW0-j AQW0-j Circuit Breakers lock Push n/ ff N NC N-NC N. In place of j, specify the Button Color Code from table.. For sub-assembled part numbers, see next page.. For accessories, see page 70.. For dimensions, see page ed switches are supplied with two keys. All units are keyed alike. AKW0 AKW0 AKW AKW0 AKW0 67

5 ømm - TW Series perators ound Flush/Extended ound with Full Shroud/ ecessed Ø 0mm, Ø 9mm Mushroom Head Ø 0mm Mushroom Head with Full Shroud Square Flush/Extended lock Push n/ff Non-Illuminated Pushbuttons (Sub-Assembled) Contact Blocks + perator + Button = Complete Part Momentary ABW-00 ABFW-00 ABW-0 ABGW-00 ABQW-00 Maintained AW-00 AFW-00 AW-0 AGW-00 AQW-00 AKW-00 Buttons ound Flush ound Extended Ø 9mm Mushroom Ø 0mm Mushroom Square Flush Square Extended ABWB-j ABWB-j ABWB-j ABWB-j ABQWB-j ABQWB-j In place of j specify the button color code from table Contact Blocks Standard Exposed Screw Fingersafe (IP0), CE marked Dummy Block N NC HW-C0 HW-C0 (early make) HW-F0 HW-F0 (early make) TW-DB HW-C0 HW-C0 (late break) HW-F0 HW-F0 (late break). Dummy blocks (no contacts) are used with an odd number of contact blocks.. Use of early and late break contacts creates a make before break function j Button Color Codes Color Code Black B Green G ed Blue S Yellow Y White W Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 675

6 ømm - TW Series Stop Switches (Assembled) Signaling Lights To be used for interpreting part numbers only, not for part number development. elays & Sockets Assembled Stop Switches A V (L) W (B) (99) (D) (N) (V) Circuit Breakers Terminal Blocks Contactors Timers Function V: Pushlock Turn eset Y: Push-Pull : Pushlock eset Illumination Blank: None L: Illuminated Series Designation W: TW Series Button/Lens Size : 9mm Mushroom : 0mm Mushroom Lens Type (illuminated units only) Blank: Standard (ribbed) B: Engravable (smooth with insert) Illuminated Circuit (illuminated unit only) 99: Full Voltage (lamp determines voltage) 6: 0V AC Step Down Transformer 6: 0V AC Step Down Transformer 86: 80V AC Step Down Transformer Lamp Voltage (full voltage illuminated units only) 6V: 6V AC/DC V: V AC/DC V: V AC/DC 0V: 0V AC (LED only) 0V: 0V AC (LED only) Button/Lens Color A: Amber : ed W: White G: Green S: Blue Y: Yellow B: Black Contact Terminal Blank: Standard N: Fingersafe (IP0) Lamp Type (illuminated units only) Blank: Incandescent D: LED Contact Arrangement 0: N 0: NC 0: N 0: : N/NC : N/ 676

7 ømm - TW Series Non-Illuminated Stop Switches Ø 0mm Pushlock Turn eset* Ø 9mm Pushlock Turn eset* Ø 0mm Push-Pull Ø 0mm Pushlock eset * Stop Switches (Assembled), continued Contacts. *Available in ed only.. In place of j, specify the Button Color Code from table.. For sub-assembled part numbers, see next page.. For accessories, see page For dimensions, see page 705. Illuminated Stop Switches Ø 0mm Pushlock Turn eset Type Ø 9mm Pushlock Turn eset Ø 0mm Push-Pull N NC N-NC N N NC N-NC N N NC N-NC N N NC N-NC N AVW0-* AVW0-* AVW-* AVW0-* AVW0-* AVW-* AVW-* AVW-* AVW-* AVW-* AYW0-j AYW0-j AYW-j AYW0-j AYW0-j AW0- * AW0- * AW- * AW0- * AW0- * Type Contacts Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage. *Available in red only.. In place of k, specify the Lens Color Code (see table above).. In place of l, specify the Full Voltage Code (lamp voltage) (see table above).. In place of m, specify the Transformer Voltage Code (see table above). 5. In place of n, specify the Lamp Type Code from table above. 6. For sub-assembly part numbers, see next page. 7. For accessories, see page For dimensions, see page 705. N-NC N N-NC N N-NC N N-NC N N-NC N N-NC N AVLW m n-* AVLW m 0n-* AVLW m 0n-* AVLW99n-*-l AVLW990n-*-l AVLW990n-*-l AVLWmn-* AVLWm0n-* AVLWm0n-* AVLW99n-*-l AVLW990n-*-l AVLW990n-*-l AYLW m n-k AYLW m 0n-k AYLW m 0n-k AYLW99n-k-l AYLW990n-k-l AYLW990n-k-l j Button Color Codes Color Black Green ed Blue White Yellow Code B G S W k LED/Lens Color Codes Color Amber Green ed Blue White Y Code A G S W l Full Voltage Codes Voltage 6V AC/DC V AC/DC V AC/DC 0V AC 0V AC Code 6V V V 0V (LED only) 0V (LED only) m Transformer Voltage Codes 0VAC 0VAC 80VAC Transformers step down to 6V. n Lamp Type Codes Lamp Incandescent LED Code Blank D Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 677

8 ømm - TW Series Transformer/ Adaptor* Stop Switches (Sub-Assembled) + Contacts + Lamp Holder + perator + Lamp + Button or Lens = Complete Part Signaling Lights *Not applicable for full voltage units perators Non-Illuminated Illuminated Buttons Ø 0mm Pushlock Turn eset Lamps Voltage 6V AC/DC LSTD-6k Ø 9/Ø 0mm Pushlock Turn eset AVWB-* LED V AC/DC V AC/DC LSTD-k LSTD-k elays & Sockets Ø 0mm Push-Pull AVW-0 AVLW-0600 Ø 9mm Pushlock Turn eset AVWB-* 0V AC 0V AC LSTD-Hk LSTD-Mk Incandescent 6V AC/DC IS-6 V AC/DC V AC/DC IS- IS- AYW-00 AYLW In place of k, specify the LED color code.. The LED contains a current-limiting resistor and a protection diode. Timers Ø 0mm Pushlock eset AW-0 Ø 0mm Push-Pull AYWB-j j Button Color Codes Color Code Black B Green G Ø 0mm Pushlock eset ed Blue S AWB-* White W Contactors. *Available in ed only. In place of j, specify the button color code from table. Yellow Y k LED/Lens Color Codes Color Code Amber A Green G ed Terminal Blocks Blue White S W Circuit Breakers 678

9 ømm - TW Series Lenses Ø 9mm Head Pushlock Turn eset Ø 0mm Head Pushlock Turn eset Ø 0mm Head Push Pull Illuminated Stop Switches (Sub-Assembled) continued Transformers/Full Voltage Modules Standard AVLWLU-* AVLWLU-* AYLWLU-k Engravable AVLWBLU-* AVLWBLU-* AYLWBLU-k. In place of k, specify the lens color code from table on previous page.. *Available only in red. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Lamp Circuit Components Application Short Lamp Holder Long Lamp Holder Lead Holder Used with a Half-size Transformer and one contact block Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks Used with TW-LH holder when using four contact blocks TW-LH TW-LH HW-LH Description Full Size Transformer 0V AC TW-T6B Standard 0V AC TW-T6B 80V AC TW-T86B 0V AC TW-F6B Fingersafe 0V AC TW-F6B 80V AC TW-F86B Half Size Transformer 0V AC TW-T6SB 0V AC TW-T6SB Full voltage model (use with even number of contacts) Standard TW-DAB Fingersafe TW-DAFB Full voltage model (use with odd number of contacts) Standard HW-DAB All Transformers step down to 6V (use 6V lamp). Contact Blocks Standard Exposed Screw Fingersafe (IP0), CE marked Dummy Block Fingersafe N NC HW-C0 HW-C0 (early make) HW-F0 HW-F0 (early make) TW-DB HW-C0 HW-C0 (late break) HW-F0 HW-F0 (late break). Dummy blocks (no contacts) are used with an odd number of contact blocks.. Use of early and late break contacts creates a make before break function HW-DAFB Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 679

10 ømm - TW Series Pilot Lights (Assembled) elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers Signaling Lights Assembled Pilot Lights A P (Q) W (B) (99) (D) (V) Function P: Pilot Light Bezel Shape Blank: ctagonal (round lenses) Q: Square Series Designation W: TW Series Lens Shape : Flat : Dome Lens Type Blank: Standard (ribbed) B: Engravable (smooth with insert included) Illumination Circuit 99: Full Voltage (lamp determines voltage) 6: 0V AC Step Down Transformer 6: 0V AC Step Down Transformer 86: 80V AC Step Down Transformer Lamp Voltage (Full Voltage Units nly) 6V: 6V AC/DC V: V AC/DC V: V AC/DC 0V: 0V AC (LED only) 0V: 0V AC (LED only) Lens Color Code A: Amber G: Green : ed S: Blue W: White Y: Yellow Lamp Type Blank: Incandescent D: LED 680

11 ømm - TW Series. Use only when interpreting part numbers. Do not use for developing part numbers.. All transformers step down to 6V. Assembled Pilot Lights ound Flat Dome Square Flat Pilot Lights (Assembled) continued Type Voltage. In place of k, specify the Lens Color Code from table below.. In place of l, specify the Full Voltage Code from table below.. In place of m, specify the Lamp Type Code from table below.. For accessories, see page For dimensions, see page For sub-assembly part numbers, see next page. 7. Yellow pilot light comes with white LED. Transformer 0VAC 0VAC 80VAC APW6m-k APW6m-k APW86m-k Full Voltage APW99m-k-l Transformer 0VAC 0VAC 80VAC APW6m-k APW6m-k APW86m-k Full Voltage APW99m-k-l Transformer 0VAC 0VAC 80VAC APQWB6m-k APQWB6m-k APQWB86m-k Full Voltage APQWB99m-k-l k Lens Color Codes Color Code Amber A Green G ed Blue S White W Yellow Y l Full Voltage Codes Voltage Code 6V AC/DC 6V V AC/DC V V AC/DC V 0V AC 0V (LED only) 0V AC 0V (LED only) m Lamp Type Codes Lamp Code Incandescent Blank LED D Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 68

12 ømm - TW Series Pilot Lights (Sub-Assembled) Transformer + perator + Lamp + Lens = Complete Part Contactors Timers elays & Sockets Signaling Lights perators ound Dome/Flat Square Lenses Dome ound Flat * Transformer not required for full voltage units. APW-99 UPQW-99 Same operator is used for full voltage as for transformer completed units. Standard Engravable APWLU-k Lamps Voltage 6V AC/DC LSTD-6k LED V AC/DC LSTD-k V AC/DC LSTD-k 0V AC LSTD-Hk 0V AC LSTD-Mk Incandescent 6V AC/DC IS-6 V AC/DC IS- V AC/DC IS-. In place of k, specify the LED color code.. The LED contains a current-limiting resistor and a protection diode.. Yellow LED not available. Use white LED. Transformers Description Standard Fingersafe All Transformers step down to 6V (use 6V lamp). 0V AC 0V AC 80V AC 0V AC 0V AC 80V AC k LED/Lens Color Codes Color Amber Green ed Blue White Yellow TW-T6B TW-T6B TW-T86B TW-F6B TW-F6B TW-F86B Code A G S W Y If clear lens is desired, use white marking lens and remove engraving insert APWLU-k APWBLU-k Terminal Blocks Square Flat APQWBLU-k Circuit Breakers. In place of k, specify the Lens Color Code from table.. Standard lenses have a ribbed lens to enhance light dispersion. Marking lenses are smooth and include an engravable insert. 68

13 ømm - TW Series Function L:Momentary Action L:Maintained Action Bezel Shape Blank: ctagonal (round lenses) F: Full Shroud (round lenses) Q: Square Series Designation W: TW series Lens Shape/Size : Standard Extended (round or square) : 9mm Mushroom : 0mm Mushroom Lens Type Blank: Standard (ribbed) B: Engravable (smooth with insert) Illumination Circuit 99: Full Voltage (lamp determines voltage) 6: 0V AC Step Down Transformer 6: 0V AC Step Down Transformer 86: 80V AC Step Down Transformer. Use only when interpreting part numbers. Do not use for developing part numbers.. Transformers step down to 6V. Illuminated Pushbuttons (Assembled) Assembled Illuminated Pushbuttons A L (F) W (B) 99 (D) (N) (V) Lamp Voltage (Full Voltage Units nly) 6V: 6V AC/DC V: V AC/DC V: V AC/DC 0V: 0V AC (LED only) 0V: 0V AC (LED only) Lens Code A: Amber G: Green : ed S: Blue W: White Y: Yellow Contact Terminal Blank: Standard N: Fingersafe Lamp Type Blank: Incandescent Lamp D: LED Lamp Contact Arrangement 0: N 0: NC 0: N 0: : N-NC : N- Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 68

14 ømm - TW Series Illuminated Pushbuttons Extended Lens Transformer Contacts N-NC N Illuminated Pushbuttons (Assembled) Momentary ALW m n-k ALW m 0n-k ALW m 0n-k Maintained ALW m n-k ALW m 0n-k ALW m 0n-k k LED/Lens Color Codes Color Amber Green ed Blue Code A G S Signaling Lights Full Voltage N-NC N ALW99n-k-l ALW990n-k-l ALW990n-k-l ALW99n-k-l ALW990n-k-l ALW990n-k-l White Yellow W Y. Mushroom lenses not available in yellow.. Yellow pushbutton comes with white LED. elays & Sockets Extended Lens with Full Shroud Transformer Full Voltage N-NC N N-NC N ALFW m n-k ALFW m 0n-k ALFW m 0n-k ALFW99n-k-l ALFW990n-k-l ALFW990n-k-l ALFW m n-k ALFW m 0n-k ALFW m 0n-k ALFW99n-k-l ALFW990n-k-l ALFW990n-k-l l Full Voltage Codes Voltage 6V AC/DC V AC/DC V AC/DC 0V AC Code 6V V V 0V (LED only) 0V AC 0V (LED only) ø9mm Mushroom Lens Transformer N-NC N ALW m n-k ALW m 0n-k ALW m 0n-k ALW mn-k ALW m0n-k ALW m 0n-k m Transformer Voltage Codes Voltage Code Timers ø0mm Mushroom Lens Full Voltage Transformer N-NC N N-NC N ALW99n-k-l ALW990n-k-l ALW990n-k-l ALW m n-k ALW m 0n-k ALW m 0n-k ALW99n-k-l ALW990n-k-l ALW990n-k-l ALW mn-k ALW m0n-k ALW m 0n-k 0VAC 6 0VAC 6 80VAC 86 Transformers step down to 6V (use 6V lamp). n Lamp Type Codes Contactors Full Voltage N-NC N ALW99n-k-l ALW990n-k-l ALW990n-k-l ALW99n-k-l ALW990n-k-l ALW990n-k-l Lamp Incandescent LED Code Blank D Terminal Blocks Square Extended Transformer Full Voltage N-NC N N-NC N ALQWB mn-k ALQWB m0n-k ALQWB m0n-k ALQWB99n-k-l ALQWB990n-k-l ALQWB990n-k-l ALQWB mn-k ALQWB m0n-k ALQWB m0n-k ALQWB99n-k-l ALQWB990n-k-l ALQWB990n-k-l Circuit Breakers. In place of k, specify the Lens Color Code (see table). Mushroom lenses not available in yellow.. In place of l, specify the Full Voltage Code (lamp voltage) (see table).. In place of m, specify the Transformer Voltage Code (see table).. In place of n, specify the Lamp Type Code from table. 5. For sub-assembly part numbers, see next page. 6. For accessories, see page For dimensions, see page Light is independent of switch position. 9. Yellow pushbutton comes with white LED. 68

15 ømm - TW Series Transformer/ Adaptor* *Not applicable for full voltage units perators Illuminated Pushbuttons (Sub-Assembled) + Contacts + Lamp Holder + perator + Lamp + Lens = Complete Part Momentary Maintained Extended ALW-0600 ALW-0600 Extended with Full Shroud ø9mm/ø0mm Mushroom ALFW-0600 ALW-0600 ALFW-0600 ALW-0600 Square/Extended ALQW-B0600 ALQW-B0600 Lenses Standard Engravable ound Extended ALWLU-k ALWBLU-k ø 9mm Mushroom Head* ø 0mm Mushroom Head* ALWLU-k ALWLU-k ALWBLU-k ALWBLU-k Square Extended ALQWBLU-k. In place of k, specify the lens color code from table on the bottom right.. *Mushroom lens not available in yellow.. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Lamps Voltage 6V AC/DC LSTD-6k LED V AC/DC LSTD-k V AC/DC LSTD-k 0V AC LSTD-Hk 0V AC LSTD-Mk Incandescent 6V AC/DC IS-6 V AC/DC IS- V AC/DC IS-. In place of k, specify the LED color code.. The LED contains a current-limiting resistor and a protection diode. Lamp Circuit Components Application Short Lamp Holder Long Lamp Holder Lead Holder Used with a Half-size Transformer and one contact block k LED/Lens Color Codes Color Code Color Code Amber A Blue S Green G White W ed Yellow Y Yellow LED not available. Use white LED. Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks Used with TW-LH holder when using four contact blocks TW-LH TW-LH HW-LH Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 685

16 ømm - TW Series Signaling Lights Contact Blocks Standard Exposed Screw Fingersafe (IP0), CE marked N HW-C0 HW-C0 (early make) HW-F0 HW-F0 (early make) Illuminated Pushbuttons (Sub-Assembled) continued NC HW-C0 HW-C0 (late break) HW-F0 HW-F0 (late break) Transformers/Full Voltage Modules Full Size Transformer Half Size Transformer Description Standard Fingersafe 0V AC 0V AC 0V AC 80V AC 0V AC 0V AC 80V AC TW-T6B TW-T6B TW-T86B TW-F6B TW-F6B TW-F86B TW-T6SB Dummy Block 0V AC TW-T6SB elays & Sockets TW-DB. Dummy blocks (no contacts) are used with an odd number of contact blocks.. Use of early and late break contacts creates a make before break function Full voltage model (use with even number of contacts) Standard Fingersafe TW-DAB TW-DAFB Full voltage model (use with odd number of contacts) Standard HW-DAB Circuit Breakers Terminal Blocks Contactors Timers Fingersafe HW-DAFB All Transformers step down to 6V (use 6V lamp)

17 ømm - TW Series Function S: Selector Switch Series Designation W: TW Series Number of Positions : -Position : -Position : -Position 5: 5-Position Spring eturn Action Blank: Maintained : Spring return from ight ( or position) : Spring return from Left ( or position) : -Way spring return from Left and ight ( position only). Use only when interpreting part numbers. Do not use for developing part numbers.. Custom contact configurations available.. Custom key removable codes available.. Portions of part number inside ( ) are optional. Non-Illuminated Selector Switches (Assembled) Assembled Selector Switches A S W () (L) 0 (N) Circuit Number (Standard circuits shown on following pages and 695.) Contacts Terminal Blank: standard N: Fingersafe (IP0) Contact Arrangement Code 0: N 0: NC 0: N 0: 0: N 0: NC : N-NC : N- perator Code Blank: Knob perator L: Lever perator K: perator Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 687

18 ømm - TW Series -Position Selector Switches Contact Mounting perator Position L Non-Illuminated Selector Switches (Assembled) continued Maintained Spring eturn from ight Spring eturn from Left L L L Signaling Lights N NC Knob Lever Knob Lever ASW0 ASWL0 ASWK0 ASW0-6 ASWL0-6 ASWK0-6 ASW0 ASWL0 ASWK0 ASW0-6 ASWL0-6 ASWK0-6 ASW0 ASWL0 ASWK0 ASW0-6 ASWL0-6 ASWK0-6 N NC Knob Lever ASW ASWL ASWK ASW ASWL ASWK ASW ASWL ASWK elays & Sockets N Knob Lever Knob Lever ASW0 ASWL0 ASWK0 ASW0-0 ASWL0-0 ASWK0-0 ASW0 ASWL0 ASWK0 ASW0-0 ASWL0-0 ASWK0-0 ASW0 ASWL0 ASWK0 ASW0-0 ASWL0-0 ASWK0-0 N Knob Lever ASW ASWL ASWK ASW ASWL ASWK ASW ASWL ASWK Timers N Knob Lever ASW- ASWL- ASWK- Circuit Breakers Terminal Blocks Contactors ASW- ASWL- ASWK- ASW- ASWL- ASWK

19 ømm - TW Series -Position Selector Switches Contact N N N N N NC Mounting Non-Illuminated Selector Switches (Assembled) continued perator Position Maintained Spring eturn from ight Spring eturn from Left Spring eturn Two-Way L C Knob Lever Knob Lever Knob Lever Knob Lever Knob Lever Knob Lever Knob Lever L ASW ASWL0 ASWK0 ASW ASWL0 ASWK0 ASW ASWL ASWK C ASW-9 ASWL-9 ASWK-9 ASW- ASWL- ASWK- ASW0 ASWL0 ASWK0 ASW ASWL0 ASWK0 L ASW ASWL0 ASWK0 ASW ASWL0 ASWK0 ASW ASWL ASWK C ASW-9 ASWL-9 ASWK-9 ASW- ASWL- ASWK- ASW0 ASWL0 ASWK0 ASW ASWL0 ASWK0. The truth table indicates the operating position of contact block when the operator is switched to that position. = n (closed contacts) = ff (open contacts) = verlapping Contacts: emain on (closed contacts) when switch is moved between these two positions.. All knob and lever selector switches come in black. ther colors are available by ordering the knob or lever separately.. Every key selector switch uses an identical key. The key is removable in any maintained position.. Custom contact configurations are available, see page Position Selector Switch Contact N Mounting perator Position Knob Lever Maintained ASW- ASWL- L ASW ASWL0 ASWK0 ASW ASWL0 ASWK0 ASW ASWL ASWK C ASW-9 ASWL-9 ASWK-9 ASW- ASWL- ASWK- ASW0 ASWL0 ASWK0 ASW ASWL0 ASWK0 5-Position Selector Switch perator Position Contact N Mounting 5 L ASW ASWL0 ASWK0 ASW ASWL0 ASWK0 ASW ASWL ASWK C ASW-9 ASWL-9 ASWK-9 ASW- ASWL- ASWK- ASW0 ASWL0 ASWK0 ASW ASWL0 ASWK0 Knob Lever Maintained 5 ASW5-50 ASW5L-50 Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 689

20 ømm - TW Series Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + perator + Knob or Lever* + Color Insert* = Complete Part Circuit Breakers Terminal Blocks Contactors Timers elays & Sockets Signaling Lights perators. *Not needed with key type switches.. Knob type shown. Positions Description Knob/Lever 5 Maintained Spring return from right Spring return from left Maintained, Cam Maintained, Cam Maintained, Cam Spring return from right, Cam Spring return from right, Cam Spring return from left, Cam Spring return from left, Cam Spring return from left/right, Cam Spring return from left/right, Cam Maintained, Standard Cam Maintained, Cam Maintained, Standard cam Maintained, Cam Maintained Spring return from right Spring return from left Maintained, Cam Maintained, Cam Maintained, Cam Spring return from right, Cam Spring return from right, Cam Spring return from left, Cam Spring return from left, Cam Spring return from left/right, Cam Spring return from left/right, Cam. Two keys are supplied with every key switch, all are keyed alike, and removable from any maintained position.. Locking rings are included with all operators. rder knobs, levers, and color inserts separately.. Different cams produce different contact actions. For details, see page switch operator supplied with black sleeve. j Handle/Insert Color Codes Color Black* Blue Green ed Yellow White Code B S G Y W *Color inserts not available in black. Knob and lever not available in white. eplacement Parts Switch Black Sleeve ASW00 ASW00 ASW00 ASW0- ASW0- ASW0- ASW0- ASW0- ASW0- ASW0- ASW0- ASW0- ASW00 ASW00- ASW500 ASW500- ASWK00 ASWK00 ASWK00 ASWK00- ASWK00- ASWK00- ASWK00- ASWK00- ASWK00- ASWK00- ASWK00- ASWK00- AKWB-B Handles and Inserts Knob Lever Color Insert Contact Blocks Standard Exposed Screw Fingersafe (IP0), CE marked Dummy Block N HW-C0 HW-C0 (early make) HW-F0 HW-F0 (early make) ASWHHY-j ASWHHL-j TW-HC-j TW-DB NC HW-C0 HW-C0 (late break) HW-F0 HW-F0 (late break). Push rod color code: Green = N contact block ed = NC contact block.. Dummy blocks (no contacts) are used with an odd number of contact blocks

21 ømm - TW Series Function SL: Illuminated Selector Switch Series Designation W: TW series Number of Positions : -Position : -Position Spring eturn Action Blank: Maintained : Spring return from ight : Spring return from Left : Two-Way spring return from Left and ight Illumination Circuit 99: Full Voltage (lamp determines voltage) 6: 0V AC Step Down Transformer 6: 0V AC Step Down Transformer 86: 80V AC Step Down Transformer Illuminated Selector Switches (Assembled) Assembled Illuminated Selector Switches A SL W () 99 (D) (N) (0) (V). Use only when interpreting part numbers. Do not use for developing part numbers.. All transformers step down to 6V (use 6V lamp). Lamp Voltage (Full Voltage Units nly) 6V: 6V AC/DC V: V AC/DC V: V AC/DC 0V: 0V AC (LED only) 0V: 0V AC (LED only) Lens Color Code A: Amber G: Green : ed S: Blue W: White Y: Yellow Contact Circuit Number Standard circuits are listed on the following pages and 695. Contact Terminal Blank: Standard N: Fingersafe Lamp Type Blank: Incandescent Lamp D: LED Lamp Contact Arrangement 0: N 0: NC 0: N 0: 0: N 0: NC : N-NC : N- Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 69

22 ømm - TW Series Illuminated -Position Selector Switches Contact Mounting perator Position L Lamp Circuit Type Illuminated Selector Switches(Assembled) continued Maintained Spring eturn from ight Spring eturn from Left L L L j Transformer Voltage Codes Voltage Code 0VAC 6 0VAC 6 80VAC 86 Signaling Lights elays & Sockets N NC Transformer Full Voltage Transformer Full Voltage ASLW j m-k ASLW99m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j m-k ASLW99m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j m-k ASLW99m-k-l ASLW j 0m-k ASLW990m-k-l N k LED/Lens Color Codes Transformer ASLW j 0m-0-k ASLW j 0m-0-k ASLW j 0m-0-k Full Voltage ASLW990m-0-k-l ASLW990m-0-k-l ASLW990m-0-k-l Color Code Amber A N Transformer ASLW j m-k ASLW j m-k ASLW j m-k Green G Full Voltage ASLW99m-k-l ASLW99m-k-l ASLW99m-k-l ed Blue S White W Illuminated -Position Selector Switches, Maintained and Spring eturn from ight Yellow Y perator Position Maintained Spring eturn From ight Spring eturn from Left Spring eturn Two-Way L C Lamp C C C Circuit Type L L L L C Contact Mounting Transformers step down to 6V (use 6V lamp). Circuit Breakers Terminal Blocks Contactors Timers N N N N N NC Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage. In place of j, specify the Transformer Voltage Code.. In place of k, specify the Lens/LED Color Code.. In place of l, specify the Full Voltage Code.. In place of m specify Lamp Type Code 5. For custom contact configurations, see page Light is independent of switch position. 7. Yellow selector switch comes with white LED. ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j m-k ASLW99m-k-l ASLW j m-9-k ASLW99m-9-k-l ASLW j m--k ASLW99m--k-l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j m-k ASLW99m-k-l ASLW j m-9-k ASLW99m-9-k-l ASLW j m--k ASLW99m--k-l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l l Full Voltage Codes Voltage Code 6V AC/DC 6V V AC/DC V V AC/DC V 0V AC 0V (LED only) 0V AC 0V (LED only) ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j m-k ASLW99m-k-l ASLW j m-9-k ASLW99m-9-k-l ASLW j m-- k ASLW99m-- k -l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l ASLW j m-k ASLW99m-k-l ASLW j m-9-k ASLW99m-9-k-l ASLW j m--k ASLW99m--k-l ASLW j 0m-k ASLW990m-k-l ASLW j 0m-k ASLW990m-k-l m Lamp Type Codes Lamp Code Incandescent LED Blank D 69

23 ømm - TW Series Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + perator + Lamp/Lead Holder + Lamp + Lens = Complete Part *Full voltage units use a full voltage adaptor (TW-DAB) instead of a transformer. Lamp holder is not included with operators, order separately. Lead holder is used when using or more contact blocks. rder separately. perators Positions Description Maintained Spring return from right Spring return from left Maintained, cam Maintained, cam Maintained, cam Spring return from right, cam Spring return from right, cam Spring return from left, cam Spring return from left, cam Spring return from left/right, cam Spring return from left/right, cam Different cams produce different contact action. For details, see Contact Arrangements on page 695. Lenses (Knobs) Knob In place of k, specify the lens color code from table. ASLWLU-k ASLW00 ASLW00 ASLW00 ASLW0- ASLW0- ASLW0- ASLW0- ASLW0- ASLW0- ASLW0- ASLW0- ASLW0- Lamps LED Voltage 6V AC/DC V AC/DC V AC/DC 0V AC 0V AC LSTD-6k LSTD-k LSTD-k LSTD-Hk LSTD-Mk Incandescent 6V AC/DC IS-6 V AC/DC V AC/DC IS- IS-. In place of k, specify the LED color code.. The LED contains a current-limiting resistor and a protection diode. k LED/Lens Color Codes Color Amber Green ed Blue White Yellow Code A G S W Y Yellow LED not available. Use white LED Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 69

24 ømm - TW Series Signaling Lights Contact Blocks Standard Exposed Screw Fingersafe (IP0), CE marked Illuminated Selector Switches (Sub-Assembled) continued Transformers/Full Voltage Modules N HW-C0 HW-C0 (early make) HW-F0 HW-F0 (early make) NC HW-C0 HW-C0 (late break) HW-F0 HW-F0 (late break) Description Full Size Transformer 0V AC TW-T6B Standard 0V AC TW-T6B 80V AC TW-T86B 0V AC TW-F6B Fingersafe 0V AC TW-F6B 80V AC TW-F86B Half Size Transformer 0V AC TW-T6SB Dummy Block 0V AC TW-T6SB elays & Sockets TW-DB. Dummy blocks (no contacts) are used with an odd number of contact blocks.. Use of early and late break contacts creates a make before break function Lamp Circuit Components Full voltage model (use with even number of contacts) Standard Fingersafe TW-DAB TW-DAFB Short Lamp Holder Application Full voltage model (use with odd number of contacts) Standard HW-DAB Timers Used with a Half-size Transformer and one contact block TW-LH Fingersafe HW-DAFB Contactors Long Lamp Holder Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks TW-LH All Transformers step down to 6V (use 6V lamp). Lead Holder Used with TW-LH holder when using four contact blocks HW-LH Circuit Breakers Terminal Blocks 69

25 ømm - TW Series How to ead Contact Arrangement Charts Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Contact Arrangement Type and quantity of switch contacts Mounting Position Circuit Number * N/D = No designation required Contact Arrangement Chart: -Position Selector Switches perator Position Contact N Circuit Number N/D NC 6 N NC N-EM NC-LB N N/D N/D 0 N N/D L Contact Block Contact Block Mounting Position Position or mounting contact blocks on operator Description HW-C0 Knob/Lever TW-DB Illuminated Knob HW-C0 Knob/Lever TW-DB Illuminated Knob HW-C0 Knob/Lever HW-C0 Illuminated Knob HW-C0 Knob/Lever HW-C0 Illuminated Knob HW-C0 Knob/Lever HW-C0 Illuminated Knob HW-C0 Knob/Lever HW-C0 Illuminated Knob HW-C0 Knob/Lever HW-C0 Illuminated Knob HW-C0 Knob/Lever HW-C0 Illuminated Knob HW-C0 HW-C0 HW-C0 HW-C0 HW-C0 HW-C0 HW-C0 HW-C0 Knob/Lever Illuminated Knob Knob/Lever Illuminated Knob. N-EM, NC-LB = Early Make, Late Break. N/D = No circuit number designation required in assembled selector switch part number.. = n (closed contacts) = ff (pen contacts) perator Position Truth table indicates the operating position of contact block when operator is switched to that position. Maintained perator Spring et. from t. Spring et. from Lt. L L L ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 L ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 ASW00 ASWK00 ASLW00 Contact Block Part number to use when ordering sub-assembly contact blocks, as required for use with corresponding mounting position Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 695

26 ømm - TW Series N NC HW-C0 Knob/Lever HW-C0 Illuminated Knob 0 HW-C0 Knob/Lever 0 HW-C0 Illuminated Knob 0 HW-C0 Knob/Lever HW-C0 Illuminated Knob ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- Signaling Lights N N/D 0 HW-C0 Knob/Lever 0 HW-C0 Illuminated Knob 0 0 HW-C0 Knob/Lever 0 HW-C0 Illuminated Knob 0 HW-C0 Knob/Lever 0 HW-C0 Illuminated Knob ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- elays & Sockets N/D 0 HW-C0 Knob/Lever HW-C0 Illuminated Knob 0 HW-C0 Knob/Lever HW-C0 Illuminated Knob ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- Timers N/D HW-C0 0 0 HW-C0 0 HW-C0 0 HW-C0 0 HW-C0 0 0 HW-C0 0 HW-C0 0 0 HW-C0 Knob/Lever Illuminated Knob Knob/Lever Illuminated Knob ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- Contactors N HW-C0 0 HW-C0 0 HW-C0 HW-C0 0 HW-C0 0 HW-C0 0 HW-C0 0 HW-C0 Knob/Lever Illuminated Knob Knob/Lever Illuminated Knob ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- Circuit Breakers Terminal Blocks N N/D 5 0 HW-C0 0 HW-C0 0 HW-C0 0 0 HW-C0 0 0 HW-C0 0 0 HW-C0 0 0 HW-C0 0 0 HW-C0 0 HW-C0 0 0 HW-C0 0 HW-C0 0 0 HW-C0 Knob/Lever Illuminated Knob Knob/Lever Illuminated Knob Knob/Lever Illuminated Knob ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW

27 ømm - TW Series Contact Arrangement Chart: -Position Selector Switches Contact NC Circuit Number N/D Mounting Position perator Position L C Contact Block 0 HW-C0 0 HW-C0 0 HW-C0 HW-C0 0 HW-C0 0 HW-C0 0 HW-C0 0 HW-C0 Description Knob/Lever Illuminated Knob Knob/Lever Illuminated Knob Maintained L C ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- perator Spring eturn from ight L C ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- Spring eturn from Left L C ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- Two-Way L C ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0-. Each operator sub-assembly is available as a - and a - for -position selector switches. The internal cam of a - is different from that of a -. This results in designated combinations of open and closed contacts in the various operator positions.. N/D = No circuit number designation required in assembled part number.. = n (closed contacts) = ff (open contacts). verlapping contacts remain on (closed) when switch is moved between these two positions. Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 697

28 ømm - TW Series To build a custom selector switch, follow these steps. Step How many positions of the switch are needed? Custom Selector Switch Building Guide Mounting Positions L # of positions (,,, 5) Signaling Lights Step How many contacts should there be? # of isolated contacts (maximum 6) elays & Sockets Timers Step Fill in the Truth Table ( = closed, 0 = open) Knob Position 5 Contacts 5 6 Contactors Step Terminal Blocks Circuit Breakers If building a position selector, skip this step. ( position selectors have only one cam) If building a,, or 5 position selector, determine appropriate cam as follows: Look at ow from above table and locate an identical row in the operator truth tables (See next page). epeat for all rows. The user must find one operator that contains all rows from above table. ecord the operator cam version. Step 5 Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. L and refer to mounting on left or right side of operator as viewed from the front of the panel. Step 6 Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages 687 or 69. In place of the Circuit Number indicate the cam number and contact arrangement as such ASW--ELCSS, where is the cam number, and contact arrangement ELC calls out individual contact mounting locations in order (see diagram above). =N, C=NC, E=N-EM, L=NC-LB, = no contact. Part number must designate all 6 possible mounting locations. Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance.. For perator Truth Tables, see next page

29 ømm - TW Series Use the following tables to build custom selector switches. Position Selector Switches ASW00 ASLW00 ASWK00 ASW0- ASWK00- ASLW0- Contact HW-C0 (N) HW-C0 (NC) HW-C0 (N-EM) HW-C0 (NC-LB) Mounting Position perator Position Left ight L L L L Position Selector Switches Contact Mounting perator Position Position Left Center ight HW-C0 L (N) HW-C0 L (NC) ASW0- ASWK00- ASLW0- ASW0- ASWK00- ASLW0- HW-C0 (N-EM) HW-C0 (NC-LB) Contact HW-C0 (N) HW-C0 (NC) HW-C0 (N-EM) HW-C0 (NC-LB) Contact HW-C0 (N) HW-C0 (NC) HW-C0 (N-EM) HW-C0 (NC-LB) L L Mounting perator Position Position Left Center ight L L L L Mounting perator Position Position Left Center ight L L L L perator Truth Tables Position Selector Switches Contact Mounting perator Position Position HW-C0 L (N) HW-C0 L ASW00 (NC) HW-C0 L (N-EM) ASW00- HW-C0 (NC-LB) Contact HW-C0 (N) HW-C0 (NC) HW-C0 (N-EM) HW-C0 (NC-LB) L Mounting perator Position Position L L L L 5 Position Selector Switches Contact Mounting perator Position Position 5 HW-C0 L (N) HW-C0 L (NC) ASW500 HW-C0 L (N-EM) ASW500- HW-C0 (NC-LB) Contact HW-C0 (N) HW-C0 (NC) HW-C0 (N-EM) HW-C0 (NC-LB) L Mounting perator Position Position 5 L L L L Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 699

30 ømm - TW Series Faceplates Nameplates TW Series NWAL NWAQL NWAS EMEGENCY STP." (9mm).76" (5mm)." (9mm) Contactors Timers elays & Sockets Signaling Lights Nameplate (blank) Nameplate (engraved).0" (5.mm) NWAL-B (black) NWAL- (red) 0.975" (5mm) 0.566" (.5mm) NWAQL-B (black) NWAQL- (red).76" (5mm) NWAS-B ø70mm NWA- NWAL-j NWAQL-j NWAS-j NWA-7. In place of j, insert either the Standard Legend Code from table below or custom engraving delimited by.. Standard engravings are available at no charge. NWA-7 comes marked Emergency Stop as shown in drawing. Standard Legend Codes Pushbuttons Pushbuttons/Selector Switches Selector Switches Legend Code Legend Code Legend Code Legend Code Legend Code AUT CLSE DWN EMEG.STP FAST FWAD HAND HIGH IN INCH JG LW LWE FF N PEN UT AISE ESET EVESE UN SLW STAT STP STP TEST UP I (Int l n) (Int l ff) EM AUT-MAN CLSE-PEN DWN-UP FAST-SLW F-EV HAND-AUT HIGH-LW JG-UN LEFT-IGHT LWE-AISE MAN-AUT FF-N N-FF PEN-CLSE AISE-LWE Terminal Blocks Circuit Breakers EV-F UN-JG UN-SAFE SAFE-UN SLW-FAST STAT-STP STP-STAT UP-DWN AUT-MAN-FF AUT-FF-MAN CLSE-FF-PEN DWN-FF-SLW FAST-FF-SLW F-FF-EV LEFT-FF-IGHT LWE-FF-AISE FF-MAN-AUT FF-SLW-FAST FF-- PEN-FF-CLSE SLW-FF-FAST SUMME-FF-WINTE UP-FF-DWN -FF- HAND-FF-AUT To order engraved nameplates, add legend code to nameplate part number. Character height based on the number of characters and size of nameplate. Standard character size is /6.. Nameplates with standard legends are the same list price as blank nameplates. Nameplate rder Form on next page

31 ømm - TW Series Custom Engraved Nameplates rder Form TW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To ensure engraving accuracy, fax it to your IDEC representative. or Distributor. Your Company Name: NWAL NWAQL NWAS Your Name: Telephone: Fax & Engraving Location Engraving Location Engraving Location A Engraving Location B Step. Specify Quantity. Enter the number of nameplates desired in the box on the right. Step. Choose Letter Size - 7/6 or /8. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: /8 size letters cannot exceed 9 characters. Step. Specify Quantity. Enter the number of nameplates desired in the box on the right. Qty Step. Choose Letter Size - 7/6 or /8. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: /8 size letters cannot exceed 9 characters. Step. Specify Quantity. Enter the number of nameplates desired in the box on the right. Qty Qty Step. Choose Letter Size - /8 or /. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: /8 size letters cannot exceed characters. Step. Specify Location. Enter the location of engraving (A or B), in the box on the right. 7/6 Letter Size /8 Letter Size IDEC ep/distributor Contact: P number (if known): IDEC ep/distributor Phone: IDEC ep/distributor Fax & characters max (for 7/6 size letters) 9 characters max (for /8 size letters) /6 Letter Size /8 Letter Size / Letter Size /8 Letter Size characters max (for 7/6 size letters) 9 characters max (for /8 size letters) characters max (for / size letters) characters max (for /8 size letters) Sample Letter Sizes 7/6 Letters: /8 Letters: Sample Letter Sizes 7/6 Letters: /8 Letters: Location Sample Letter Sizes / Letters: /8 Letters: Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 70

32 ømm - TW Series Switch Engraving rder Form TW Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To ensure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: Telephone: Name: Fax: Signaling Lights Address: P: to be Engraved: elays & Sockets Please check one of the boxes below to indicate your choice of engraving options: # of Lines Letter Height Square Switch Max. Characters Per Line # of Lines Letter Height ound Switch Max. Characters Per Line ø9mm, ø0mm Mushroom Head # of Lines Engraving Engraving Area Area Letter Height Max. Characters Per Line 5/ 6 5/ 5 5/ 5 Engraving Area /8 6 /8 6 /8 5 Timers 5/ 6 5/ 5 5/ 7 Engraving Area /8 5 /8 6 /8 7 /8 6 /8 5 / 5 / 5 Contactors. Above mentioned specifications hold true for standard size pushbuttons (round and square).. Engraving Area can be engraved for 0mm mushroom Head non-illuminated push button only.. Engraving is done on the button itself for non-illuminated push buttons and on marking plate for illuminated push buttons and pilot lights.. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters. Enter text to be engraved: Sample Letter Sizes Terminal Blocks Line : Line : Line : Line : /8 Letters: 5/ Letters: Circuit Breakers For IDEC Internal Use nly: Work rder #: 70

33 ømm - TW Series TW Series Accessories Accessories Item Appearance Description/Usage Lamp emoval Tool ubber tool used to install or remove LED s and incandescent lamps -55 Contact Block emover Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used to determine panel thickness adjustment. Nut Locking Wrench Used in - locking wrench to tighten locking nuts inside square bezel TW-KQ Metal Bezel Plastic Bezel Boot/Cover Anti-otation ing Chrome plated bezels tighten onto operator (replacement for damaged bezels) Black plastic bezels for square buttons (replacement for damaged bezels) Used to cover and protect pushbuttons Standard octagonal units (chrome-pl.) Full shroud octagonal units (chrome-pl.) Full shroud mushroom head units Ø 0mm ound flush units (black plastic) ound extended units (black plastic) Square units (black plastic) Square units with full shroud (black plastic) Waterproof lens cover for square pilot lights Waterproof lens cover for square illuminated buttons Clear boot for round flush units Clear boot for round extended units *In place of asterisk, specify ubber Boot color: B (black), G (green), (red), Y (yellow) - (nitril rubber) ing to prevent operator base from rotating in the mounting hole. Used when nameplate is not used Mounting Hole Plug Black rubber plug fills unused mounting holes in panel. B- Metallic Mounting Hole Plug For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of kfg-cm maximum Degree of protection: IP66 TW-KC AW-8 AW-F8 AW-G AW-PB AW-FPB AW-QB AW-QFB APW00LN APW00L C- C- CW-* GL- LW9Z-BM eplacement s Pair of keys (#0) TW-SK eplacement Black Sleeve for switch AKWB-B Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 70

34 ømm - TW Series Item Appearance Description/Usage Metal Button Guard Used on flush buttons to prevent inadvertent actuation LW-C Terminal Tab Adaptor Quick- connect terminals #50 (7/6 x /6 ) single tab TW-FA Signaling Lights Lock-out Adaptor Used to provide lock-out protection for pushbuttons and knob selector switches: Up to Ø 0mm mushroom head size (Padlock not included.) Not applicable for e-stops. HW9Z-KL TW to TWTD Adaptor Used to mount TW series control unit (except square units) Ø 7/8 (mm) into a Ø -/6 (mm) panel cut-out. TWN-A8 elays & Sockets eplacement Marking Plates White plastic engraving plate for use on all illuminated units (included in each lens). May be used to capture printed mylar insert (not supplied by IDEC) under lens face. ound Pushbutton (Ømm) ound Pilot Light (Ø mm) Mushroom Pushbutton (Ø mm) Square Pilot Light (q mm) Square Pushbutton (q mm) ALWB APWB ALWB APQWB ALQWB Timers Fingersafe Covers for TW Series Appearance Description Used with Fingersafe terminal cover, adds 6mm to overall depth APW and UPQW full voltage pilot lights APS-PVL Contactors Fingersafe terminal cover, adds.5mm to overall depth. ne required for each contact, only for rearmost terminals Non-illuminated pushbuttons and selectors HW-VL Terminal Blocks Fingersafe terminal cover, adds mm to overall depth APW and UPQW transformer pilot lights, and illuminated pushbuttons and illuminated selectors HW-VL Fingersafe terminal cover for contacts. Full voltage illuminated pushbuttons and selectors HW-VL Circuit Breakers Fingersafe terminal cover for full voltage adaptor, adds mm to depth Fingersafe terminal cover for half size transformer adaptor, adds mm to depth Full voltage illuminated pushbuttons and selectors Illuminated pushbuttons and selectors HW-VL5 HW-VL6 70

35 ømm - TW Series Pushbuttons Dimensions Flush Extended Extended with Full Shroud M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) to 6 ø ø9 M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) to 6 ø ø9 9 M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) to 6 9mm Mushroom 0mm Mushroom Mushroom with Full Shroud M.5 Terminal Screws 8.5 (- block) 68.5 (- blocks) to 6.5 ø9 M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) to 6.5 ø0 M.5 Terminal Screw 8.5 (- blocks) 68.5 (- blocks) 9mm Push-Lock-Turn-eset 0mm Push-Lock-Turn-eset lock Push n/ff M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) to 6 eset Angle 75.5 ø9 M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) to 6 eset Angle 75.5 ø0 M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) 0mm Pushlock reset 0mm Push-Pull Square Flush M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) Square Extended M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) to Selector Switches M.5 Terminal Screws 8.5 ( blocks) 68.5 ( blocks) to 6 5 ø0 to 6 5 ø ø9 eset (unlock) 5 M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) M.5 Terminal Screws 8.5 ( blocks) 68.5 ( blocks) to ø0 to 6 5 ø9 ø5 M.5 Terminal Screws 8.5 (- blocks) 68.5 (- blocks) M.5 Teminal Screws 8.5 ( blocks) 68.5 ( blocks) 9.5 ø ø9 to ø6 to 6 to 6 ø9 5 to 6 9 ø ø9 eset (unlock) 5 Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 705

36 ømm - TW Series Illuminated Pushbuttons Dimensions continued Extended Extended with Full Shroud Square Extended to 6 ø ø9 to 6 ø ø9 to 6 5 Signaling Lights 9 Marking plate: ø5.5mm 0 0 Marking plate: ø5.5mm 9mm Push-Turn-eset 0mm Push-Turn-eset Mushroom to 6 eset Angle: 75 to 6 eset Angle 75 to 6 Marking plate: mm ø9 elays & Sockets ø0 ø9 Push-Pull.5 to 6 ø0 Marking plate: ø.9mm.5 Marking plate: ø.9mm.5 Marking plate: ø.9mm Timers 5.5 Marking plate: ø.9mm Illuminated Selector Switches Contact Block with Full Voltage Adaptor Transformer ( blocks) Contact Block with Half Size Transformer M.5 Terminal Screws to 6 to Contactors Contact Blocks with Full Voltage Adaptor Transformer ( blocks) Contact Blocks with Half Size Transformer M.5 Terminal Screw to 6mm M.5 Terminal Screws to to Terminal Blocks Contact Blocks with Full Voltage Adaptor Contact Blocks with Full Voltage Adaptor Contact Blocks with Half Size Transformer M.5 Terminal Screws to to 6 Circuit Breakers 68.5 M.5 Terminal Screws

37 ømm - TW Series Pilot Lights ound Flush APW Full Voltage to ø ø9 ound Flush Marking Type APWB Full Voltage to ø ø9 Dome APW Full Voltage 8.5 to 6 5 ø.6 ø9 Marking plate: ø5.5 mm Square Flush Marking Type APQWB Full Voltage to Marking plate: mm Illuminated Selector Switches M.5 Terminal Screws A: 6.5 ( blocks) 8.5 ( blocks) B: 86.5 ( blocks), 06.5 ( blocks) to 6 5 ø ø9 Dimensions continued ound Flush APW Transformer M.5 Terminal Screw to 6 7 ø ø9 ound Flush Marking Type APWB Transformer M.5 Terminal Screw to 6 7 Dome APW Transformer M.5 Terminal Screw ø ø9 to 6 ø.6 ø9 Marking plate: ø5.5 mm Square Flush Marking Type APQWB Transformer M.5 Terminal Screw to Marking plate: mm Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 707

38 .5.5 ømm - TW Series Signaling Lights elays & Sockets Panel Cut-ut B Diagram A D C Pushbuttons Pilot Light Dimensions continued Part Illuminated Pushbuttons Selector Switches Illuminated Selector Switches.The Ø 0. (Ø.5mm) recess is necessary when either the nameplate or anti-rotation ring is used.. *>.0 (6mm) for - or -position. >.95 (50mm) for - or 5-position. Accessory Dimensions GL- Anti-otation ing 0. ø ø LW-C Metal Button Guard Mounting Centers 50 min. ø t CW- Pushbutton ubber Boot M P.0 ø ø Button installed P.0 M Dimension A B C D Ø 0. (.5mm) ø 9 ø6 ø.95 (50mm);.76 (5mm) minimum Button installed Ø (.mm) B- Mounting Hole ubber Plug ø9 ø5.7 (mm) Std. ctagonal >.56 (0mm) Large Mushroom.7 (mm) *See note. Flush Extended HW9Z-KL Lock-out Adaptor AW-PB ound Plastic Bezel AW-FPB ound Plastic w/full Shroud Timers to. ø9 ø AW-QFB Square Full Shroud Contactors 70 ø50 (ID: ø.) ø. hole ø8 9.5 Finger-Safe Cover Dimensions (inside) Waterproof ubber Gasket 0.5t HW-VL6 HW-VL5 HW-VL Ø Terminal Blocks HW-VL Ø6. HW-VL APS-PVL Circuit Breakers Ø

39 ømm - TW Series Component Construction and General Instructions TW Series Instructions for Switches and Pilot Devices TW Series: Adjustment for The panel thickness ring provides adjustment from 0.0 to 0. ( to 6mm) in 0.00 (0.mm) increments. otate the ring until the markings around the periphery are aligned for the desired thickness, as shown below. Scale on Adjustment (in 0. mm) mm Ex. Panel thickness mm 5 6 mm Scale (in mm on the operator) A Ex. Panel thickness.6 mm Note: When a nameplate or an anti-rotation ring is used, add 0.0 (0.8mm) to the panel thickness dimension. An adjustment for panel thicknesses shown below can be made quickly by using the contact block remover tool. Tool TW-KC mm.6 mm mm. mm.5 mm. mm Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 709

40 ømm - TW Series Signaling Lights Pilot Lights and Pushbuttons Instructions continued IMPTANT: Install the body of the TW control unit with the panel thickness scale facing up. ctagonal and ound Bezels ctagonal and round bezels screw into the operator. Use a locking ring wrench (optional) for secure tightening and easy removal. ound flush and extended buttons snap onto the operator base. Mushroom buttons screw onto the operator base. Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. ound Marking Unit Insert marking plate under lens Press in Marking Plate Lens Press in round flush and extended lens. Screw in mushroom lens elays & Sockets Square Bezels Square bezels are installed in a -step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally, install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base. Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on. Square Marking Units Pilot Light Illuminated Pushbutton Timers Insert marking plate under lens Square Lens Insert Marking Plate Insert marking plate under lens Square Lens Press in Marking Plate Lens etainer Waterproof Lens Contactors To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the indentation and lift out the plate. The lens retainer can be removed by pressing a /6 screwdriver into one of the recesses. Terminal Blocks Circuit Breakers Marking Plate Engraving Area Shape Engraving Area Used With ound Ø 0.55 (mm) Illuminated pushbuttons ALWB Ø 0.55 (mm) Pilot lights APWB Mushroom Ø 0.55 (mm) Illuminated mushroom ALWB Square q 0.8 (mm) Square pilot lights APQWB Square q 0.8 (mm) Square illuminated pushbuttons ALQWB 70

41 ømm - TW Series Selector Switches Instructions, continued The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC) into the handle and then press handle into the operator, as shown below. Illuminated Selector Switch emove color insert before pulling out the handle. Standard perating Positions ecess Selector Switch (non-illuminated) Press in handle Press in color insert -Postion, 90º -Postion, 5º -Postion, 5º 5-Postion, º Positions: Non-Illuminated -Position perators Installation 0 0 TW Pilot Lights Make sure slot is facing up 0 Terminal = Positive Terminal = Negative Lamp holder is installed as shown, due to polarity. Lead holder (used with two stacks of contact blocks ) does not have polarity. Installation of LED Illuminated Units AC transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode with DC power supply to protect against surges and noise.) Diode Terminal Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. LED TW Illuminated Pushbuttons, TW Selector Switches (AC Transformer or Full Voltage) Terminal 0 5 Signaling Lights elays & Sockets Timers Contactors Terminal Blocks Circuit Breakers IDEC () USA & Canada 7

Switches & Pilot Devices

Switches & Pilot Devices ømm - HW Series Key features: ocking lever removable contact blocks Finger-safe IP0 contacts as standard, other terminal styles available Tamperproof construction All E-stops meet EN8 and are compliant

More information

TWTD Series: Heavy duty switches built to last

TWTD Series: Heavy duty switches built to last ø0mm - TWTD Series iltight TWTD Series Full Size NEMA Pushbuttons TWTD Series: Heavy duty switches built to last features include: Variety of button sizes up to 9/6" (65mm) Rugged construction includes

More information

Separate units: Blocks

Separate units: Blocks Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL

More information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features: RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator

More information

Switches & Pilot Devices

Switches & Pilot Devices ø0mm - Series Key features: Wide variety of heavy-duty oiltight cam switches Operators available up to positions Switches made with a double circuit contact block Contact blocks rated 00V, 0A Ideal for

More information

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only) 1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT PDT PDT RH Series Compact

More information

Model Number Structure

Model Number Structure General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long

More information

RJ Series Slim Power Relays

RJ Series Slim Power Relays RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

FM series position switches

FM series position switches FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

General data. 13/20 Siemens IC Overview Front plate mounting

General data. 13/20 Siemens IC Overview Front plate mounting General data Overview Front plate mounting D C B E A F D NSD0_00029b B C A A B C D E F Actuator Front plate Holder Contact block Lampholder Support element For actuators see page /25 to /62. For contact

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Section. Display Lights Selection Guides... C 2. SignaLight Towers 70mm LT7 Modular Series... C 4 56mm LT1 Series...

Section. Display Lights  Selection Guides... C 2. SignaLight Towers 70mm LT7 Modular Series... C 4 56mm LT1 Series... Section New Selection Guides... 2 SignaLight Towers 70mm LT7 Modular Series...... 4 56mm LT1 Series.............. 7 Panel Mounting Annunciators SL30 Series, 1.18" (30mm)... 14 SL30-IPS Series 1.18" (30mm)

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS Timers DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web:  - Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996

More information

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.

More information

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty. Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions

More information

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄

Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6  USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄ SU Series: DIN Rail Snap-Mount SU Series: DIN Rail Snap-Mount SUS-L SUS-L -blade DIN-mount/surface mount -blade DIN-mount/surface mount Spring clamp terminals Spring clamp terminals - AWG - AWG 0A A (using

More information

MINIATURE RELAY FOR WIDER APPLICATIONS

MINIATURE RELAY FOR WIDER APPLICATIONS TÜV Rheinland HJ MINIATURE RELAY FOR WIDER APPLICATIONS HJ RELAYS FEATURES contact arrangements Form C (for A 0 V AC), Form C (for 0 A 0 V AC)* Excellent contact reliability by Au plating Environmentally

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

1.3. Pushbuttons and Indicating Lights.

1.3. Pushbuttons and Indicating Lights. .3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Page Features.............................. V7-T-5 Product Selection M22 Assembled Control Stations........ V7-T-6 Commercial Control

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations

More information

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer OMRON Analog Set Multifunction Timers Series To view data sheets, click on any link below: - Standard Timer -G - Star-Delta Timer -F - Twin Timer -H - Power OFF- Delay Timer Multifunction Timer Analog

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Sorenson Lighted Controls

Sorenson Lighted Controls Sorenson Lighted Controls Illuminating Innovation 9 INDICATOR CATALOG New Products Located on Pages - Sorenson Lighted Controls Illuminating Innovation ORDER TERMS & CONDITIONS Minimum OEM Order Value:

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

onlinecomponents.com

onlinecomponents.com Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

Components for safety applications Preventa safety modules

Components for safety applications Preventa safety modules Selection guide Applications Modules For Emergency Stop and limit switch monitoring (modules integrated in Micro PLCs) Conforming to standards Machine IEC 204-, EN 292, EN 48 assemblies EN 60204- Principles

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION MICRO SWITCH Key-Operated Safety Interlock Switch GK Series DESCRIPTION MICRO SWITCH GK Series switches are key-operated safety interlock rugged metal switches which monitor the positions of gates, guards,

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101 CustomAS-Interface enclosures Overview There are two types of custom solutions for AS-Interface: The front panel module and the SIRIUS 3SB3 enclosed stations. NC Contacts AS-Interface enclosure Ordering

More information

Snap Action Switches Technical Guide

Snap Action Switches Technical Guide These basic principles apply to all our precision switches. The specific characteristics of each model are given in more detail in the relevant production sections. Switch construction Single-pole changeover

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

Self-Powered Counters H7ET

Self-Powered Counters H7ET Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

selector switch Selection diagram SELECTOR TYPE HANDLE TYPE short handle long handle knob SELECTOR COLOUR white red green yellow

selector switch Selection diagram SELECTOR TYPE HANDLE TYPE short handle long handle knob SELECTOR COLOUR white red green yellow Selector switches Selection diagram SELECTOR TYPE SE selector switch SL illuminated selector switch HANDLE TYPE 1 2 4 short handle long handle knob SELECTOR COLOUR 2 3 4 5 FIXING RING 6 8 1 1 3 plastic

More information

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors

More information

20 - Arc Guard Systems

20 - Arc Guard Systems Arc Guard Index Arc Guard - Arc Guard Arc Guard...1 -.14 Selection Arc Guard System, description...6...2...2 Description,...1 Description,...1 Description, with detectors...4 Description,...5 Detectors

More information

Control module CP-A CM

Control module CP-A CM Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data

More information

XT IEC Power Control Miniature Controls

XT IEC Power Control Miniature Controls Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

02/11/2015

02/11/2015 Standstill monitoring KSW3-JS Part number 85102331 Function "Stillstand detection without sensors" Independent of rotation direction Security with redundancy and feedback circuit 3 forcibly guided "NO"

More information

Relays & Sockets. Switching & Controls.

Relays & Sockets. Switching & Controls. Switching & Controls For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos & upgrades Part confi

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION MICRO SWITCH Electromechanical Safety Switches GSS Series DESCRIPTION Honeywell s MICRO SWITCH GSS Series electromechanical safety switches are comprised of different groups of safety switches designed

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

40 Series - Miniature P.C.B. Relays A

40 Series - Miniature P.C.B. Relays A ..4..4..4 40 Series - Miniature P.C.B. Relays 8-0 - 6 A - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./0 µs) between coil and contacts - Ambient

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed) DB123399 DB116619 Country approval pictograms itl, itli, itls, itlc, itlm IEC/EN 60669-2-2 itls: IEC/EN 60947-5-1 Impulse relays B106126-34 B106128-34 itl b The impulse relays are used to control, by means

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

Multi-voltage Multi-function. Wiring diagram (without control signal)

Multi-voltage Multi-function. Wiring diagram (without control signal) 80 Modular timers 16 A 80 Multi-function and mono-function timer range 80.01T - Multi-function & multi-voltage 80.11T - On-delay, multi-voltage Complies with EN 45545-2:2013 (protection against fire of

More information

Zelio Plug-In Relays. RXG interface relays. Catalog

Zelio Plug-In Relays. RXG interface relays. Catalog Zelio Plug-In Relays Catalog 204 Contents Zelio Plug-In Relays bbintroduction.... 3 bbspecifications.................................................... 4 bbreferences... 7 bbdimensions.... 0 bbwiring

More information

E x hibitor TOKISTAR TOKISTAR LIGHTING

E x hibitor TOKISTAR TOKISTAR LIGHTING E x hibitor TOKISTAR TOKISTAR LIGHTING Exhibitor TM T okistar Exhibitor Series is a wet-location festoon lighting system used in amusement parks, shopping centers, street decorations and promenades. Exhibitor

More information

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max. TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins

More information

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Product Bulletin Code No. LIT-977319 Issued September 26, 2014 The VA-9070 Series Electric Rotary Actuators for Two-Position

More information

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

IDEC LUMIFA Family LED Lighting Solutions

IDEC LUMIFA Family LED Lighting Solutions IDEC LUMIFA Family LED Lighting Solutions LUMIFA Lighting your way For over two decades, IDEC has produced LEDs for applications requiring indicator lights and signaling towers. Which is why it was a natural

More information

Bulletin 800MR/800MB Push Buttons

Bulletin 800MR/800MB Push Buttons ulletin 800MR/800M Push uttons ulletin 800MR uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Round operators ul. 800MR ulletin 800M uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight

More information

Toyota Tundra Interior Light Upgrade

Toyota Tundra Interior Light Upgrade Toyota Tundra 2012- Interior Light Upgrade Part Number: 00016-00095 Accessory Code: IL2 General Applicability All models of Tundra Kit Contents Item # Quantity Reqd. Description 1 1 Y Adapter 2 1 Wire

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 2OC Product availability : Stock - Normally stocked in distribution facility Price* : 189.00 USD Main Range of product

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS-(S) Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays .4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................

More information

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel) DESCRIPTION The MCHXXX Control Handle is intended for open-loop control of electrohydraulic proportional valves utilizing pulse width modulated (PWM) outputs to optimize valve performance. Adjustments

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output

More information

Breakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories

Breakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Breakcontact,Front Partno. M22-K01 Articleno. 216378 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction size NZM1/2/3/4

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

RCMS460 and RCMS490 Series

RCMS460 and RCMS490 Series 4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.

More information

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34. MUELLER SMALL DRILLING MACHINES 2.1 Shaded area indicates change Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines

More information

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY The BE1-87G is a single or three-phase solid-state variable percentage differential relay designed to provide selective, high-speed, differential protection

More information

83 Series - Modular timers 16 A. Features

83 Series - Modular timers 16 A. Features Features 83 Series - Modular timers 16 A 83.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 83.11 - delay, multi-voltage 22.5 mm wide Six time scales from 0.1s to 20h High

More information