External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

Size: px
Start display at page:

Download "External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump"

Transcription

1 + (0) External control electronics for the SYDFE control of the A0VSO axial piston variable displacement pmp Type VT 0 RE 0 Edition: 0-0 Replaces:. Component series X Analog, Ero-card format Part of the SYDFE pressre and flow control system (component series X, X and X) for the control of the axial piston variable displacement pmp A0VSO... with SYDFE control via valve VT-DFP...X H09 Featres Implementation of the electronic fnctions of the SYDFE control; pressre and swivel angle control; optional power limitation Pressre controller circitry can be adjsted and switched to two existing hydralic flid volmes (actators pls lines) Differential amplifier inpts Controller for valve spool position Minimm vale generator for pressre and swivel angle controller Self-timed otpt stage Pressre-dependent leakage compensation (can be switched off) Reverse polarity protection for voltage spply Switchable actal pressre vale inpt (crrent, voltage, range) LED displays on the front plate for the operating state Display instrment on the front plate for actal swivel angle vale (optional) Power limitation with internal or external command vale presetting (optional) Contents Featres Ordering codes Fnctional description Block diagram/pin assignment Technical data Electronic card: Display and adjstment elements 8 Front plate: Display and adjstment elements, measring sockets 9 Dimensions 0 Bosch Rexroth AG, RE 0, edition: 0-0 Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

2 + (0) /0 VT 0 Control electronics Ordering codes VT 0 X / 0 0 External control electronics for the SYDFE control of the A0VSO axial piston variable displacement pmp VT 0 0 Component series 0 to 9 (0 to 9: Unchanged technical data and pin assignment) X Additional fnctions 0 Withot power limitation/withot display instrment Withot power limitation/with display instrment With power limitation/with display instrment 0 For IW9 swivel angle sensor (standard) 0 Preferred types Material no Type VT 0-X/-0 VT 0-X/-0 VT 0-X/-0 Recommended accessories Card holder: Open card holder VT 00--X/D (see data sheet 998) Power spply nit: Type VT-NE-X, see data sheet 999 Compact power spply nit /0 VAC VDC Otpt (0 W) for VT-0 spply Otpt ( W) for the spply of pressre transdcers; e.g. type HM or HM, see data sheet 99 Bosch Rexroth AG, RE 0, edition: 0-0 Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

3 + (0) Control electronics VT 0 /0 Fnctional description The analog control electronics VT0-X/... is designed as insertion card in ero format. It is provided with a command vale inpt each for pressre and swivel angle [] as a standard (optional power limitation). The actal pressre vale is measred with a pressre transdcer. The position transdcer at the pmp measres the actal swivel angle vale. The measred actal vales are processed in amplifier [] and [] and compared with the provided command vales. The minimm vale generator [] controls that only controller [] or [0] which is allocated to the reqested operating point is atomatically activated. The otpt signal of the minimm vale generator [] becomes the command vale for the valve control loop. The optionally available power limitation is atomatically activated by the provision of a sitable command vale. The power command vale can be provided internally or externally. If necessary, it limits the swivel angle command vale by means of a minimm vale generator []. The reslting swivel angle command vale can be measred at socket. The actal valve vale (position of the valve spool) is measred with an indctive position transdcer. An oscillator/demodlator switch [] enhances the signal. The control deviation is generated and processed in the controller for the valve spool position [8]. The otpt signal of the valve controller [8] forms the command vale for the self-timing power otpt stage [9] which controls the proportional solenoid of the valve. The control electronics is eqipped with a falt message otpt where a voltage of 0 V is applied in case of error (= low-active). At the same time, the "Err." LED flashes. Depending on the jmper J configration, the valve otpt can be de-energized in case of an error message. Cases for error messages: Defective internal voltage spply The actal pressre vale is greater than the admissible system pressre (socket : p act >. V) No enable signal at port c Cable break or range of the swivel angle retrn exceeded Cable break or range of the valve spool retrn exceeded Cable break "pressre transdcer" (for adjstments...0 ma, 0... V and...0 V) Control error (control difference x controller amplification) is greater than V (0%) for more than second In case of error, the electronics can be configred so that the otpt stage is de-energized and the valve spool is pressed to its mechanical end position. This cases the pmp to swivel back. The error can only be acknowledged by resetting the enable signal. [ ] = assignment to the block diagram on page and RE 0, edition: 0-0, Bosch Rexroth AG Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

4 + (0) /0 VT 0 Control electronics Block diagram/pin assignment p SOLL V Reference c c [] Pressre command vale Switch T D 0/+ V p IST 0... V V 0... V...0 V ma...0 ma Reference Pressre controller deactivated Master/slave 0/+ V SW SOLL SW IST-Master or power limit V Enable c 8c 0c 8a Version VT0-X/-0 or.../-0 ±0 V Reference ±0 V Reference 0/+ V +U B 0 V Shield System grond V M0 + V c c 8c 0c c 0a a 8a a c 0a a a [] FE-contr. ) Actal pressre vale Adjstment J R R D S.- [] Adjstment + Active swivel angle + command vale Single pmp/ combination [] MIN J 00 % 8 cw + R ccw + DIV SW MAX p 0 % IST Power limit Version VT0-X/-0 Ub ) = = +V 0V -V p IST Leakage compensation D S.- Enable ) > +, V < - 0, V 9 0 Pressre control deactivated [] [] P F Pressre controller & P Swivel angle controller [0] Enable valve otpt stage Abbreviations for the signals p SOLL Pressre command vale p IST Actal pressre vale Switch T D Oil volme selection SW SOLL Swivel angle command vale SW IST Actal swivel angle vale SW IST-Master Actal master swivel angle vale FE contr. Pressre controller disabled For the fnction of the jmpers and switches on the electronic card see page 8. For the meaning of the measring sockets, and display and adjstment elements (potentiometer) on the front plate, see page 9. Bosch Rexroth AG, RE 0, edition: 0-0 Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

5 + (0) Control electronics VT 0 /0 8a Actal valve vale Command vale of valve p-control ) Enable valve otpt stage R = [8] [9] P [] J8 = ON i M0 a a a a 8c 0c J8 = ON: Compatible with VT 0-X Valve position sensor ) Proportional solenoid ) [] MIN > + V < - V Actal swivel angle vale t = sec [] = a 0a a a () ( ) Swivel angle sensor IW9 ) c p IST V p-ist v-soll -control ) c a SW IST ±0 V Swivel angle control enabled & 8a Power limitation active J9 Power Limiter ) Collective error Version VT0-X/-0 Actal valve vale error Primary Secondary +V Actal swivel angle vale error <0 V v-ist KB-TP KB-TS sw-ist KB-IW9 + V US J F Compatible with VT 0-X: J = OFF a c Error message "= HIGH" Error message "= LOW" -V U+U > V nsym Error ) Diagnostic LEDs on the printed circit board v-soll Persisting control deviation is too great v-ist Actal valve vale error - exceeding of range p-ist Actal pressre vale error sw-ist Actal swivel angle vale error - exceeds range KB-TP Valve position sensor cable break - primary KB-TS Valve position sensor cable break - secondary KB-IW9 Swivel angle position sensor cable break + V US + V ndervoltage (internal power spply nit) nsym Internal voltage spply is asymmetric ) LED displays on the front plate (for meaning see page 9) ) For frther information with regard to the connection, see operating instrctions 00-B RE 0, edition: 0-0, Bosch Rexroth AG Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

6 + (0) /0 VT 0 Control electronics Technical data (for applications otside these parameters, please conslt s.) Operating voltage U B V DC + 0 0% (.. V) Upper limit vale B(t) max V Lower limit vale B(t) min V Crrent consmption I rated (I max) 0. A (. A) Analog command vale inpts Pressre p SOLL U e 0 0 V; R e > 0 kω Standard ±0 V; regenerative: 0 0 V; Swivel angle SW SOLL U e R e > 0 kω Power (p SW) max 0 0 V, R e > 0 kω or U e SW IST-Master ±0 V, R e > 0 kω Analog actal vale inpts U e 0... V, V; R e > 0 kω Pressre p IST 0... V,...0 V; R e > 0 kω I e ma,...0 ma; R B = 00 Ω Enable inpt (PLC) U e > V Analog otpts Otpt stage Solenoid crrent I max. A; R 0 = Ω Oscillator Freqency f. khz Amplitde for IW9 (actal swivel angle vale) U ss V (port a /a) Amplitde for DM (actal valve vale) U ss. V (port 8a) Signal voltage otpts Actal pressre vale U 0 0 V Actal swivel angle vale U 0 V +0 V 00% % Axiliary voltages for external se U ±( V + % %); I max = 0 ma Measring sockets, fnction and nmber Pressre command vale (p SOLL) U 0 0 V 0 +00%; R i = kω Actal pressre vale (p IST) U 0 0 V 0 +00%; R i = kω Swivel angle command vale (SW SOLL) U ±0 V ±00%; R i = kω Actal swivel angle vale (SW IST) U ±0 V ±00%; R i = kω Valve command vale (x_v soll) U ±0 V ±00%; R i = kω Actal valve vale (x_v ist) U ±0 V ±00%; R i = kω Active swivel angle command vale U ±0 V ±00%; R i = kω Power limit (P max) 8 U 0 +0 V 0 +00%; R i = kω Reference 9 and 0 Message otpts Swivel angle control enabled U U B V (I max = 0 ma) Power limitation active U U B V (I max = 0 ma) Error messages Low-active U U B V (I max = 0 ma); error at U < V High-active U U B V (I max = 0 ma) Type of sensor Swivel angle IW9 (indctive position transdcer) Throttle circit; ± mm; -condctor connection Valve DM (indctive position transdcer) Transformer circit; ±0. mm; -condctor connection Bosch Rexroth AG, RE 0, edition: 0-0 Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

7 + (0) Control electronics VT 0 /0 Technical data (for applications otside these parameters, please conslt s.) Type of connection Compatibility pin male mltipoint connector; DIN ; design D Card dimensions Ero-card 00 x 0 mm; DIN 9 Front plate dimensions Height HE (8. mm) Condctor path side width TE Component side width VT 0-X/-0 TE VT 0-X/-0 and VT 0-X/-0 TE Operating temperatre range 0 +0 C Storage temperatre range 0 +0 C Weight Electronic card withot display m 0.9 kg Electronic card with display m 0. kg RE 0, edition: 0-0, Bosch Rexroth AG Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

8 + (0) /0 VT 0 Control electronics Electronic card: Display and adjstment elements Leakage Jmpers compensation J J Off OFF OFF % OFF ON % ON OFF 0% ON ON v-soll KB-TS KB-TB KB-IW9 p-ist v-ist nsym sw-ist Valve command vale monitoring On Off * US +V Jmpers J9 ON OFF OFF ON * (standard) Reference for position transdcer Diagnostic LEDs For a description, see page and the operating instrctions 00-B Regenerative Jmpers operation J J On ON OFF Off OFF ON Fnction Jmpers pin 8a ** J Pressre control OFF on/off Master/slave ON on/off ** Only for versions withot power limitation (VT 0-X/-0 nd VT 0-X/-0) OFF (standard) Reference for actal pressre vale ( ) Valve deactivation in case of error Jmpers J Active OFF * Inactive ON ON * Compatible with VT 0-X OFF Selection for analog inpt at pin 8c Actal master swivel angle vale External power limitation Jmpers J Bridge - - Pressre controller Switch S Jmpers p amplification..8 J 8.0 OFF OFF OFF.8 OFF ON OFF.0 OFF OFF ON.0 OFF ON ON. ON OFF ON.0 ON ON ON Actal pressre vale amplification -fold -fold Jmpers J0 OFF ON Signal adjstment of Switch S actal pressre vale V V OFF OFF OFF OFF OFF OFF ON ON E...0 V OFF OFF OFF OFF ON OFF OFF ON D 0... V OFF OFF ON ON OFF OFF ON ON F 0... V OFF OFF ON ON ON OFF OFF ON B ma ON ON OFF OFF OFF OFF ON ON C...0 ma ON ON OFF OFF ON ON OFF OFF Volme adjstment of pressre controller Inpt switch T D Switch S = OFF....0 l OFF OFF OFF. l OFF ON OFF 0.0 l ON ON OFF.0 l ON OFF ON 0.0 l OFF ON ON.0 l ON ON ON Inpt switch T D = ON Switch S.... l OFF OFF OFF 0.0 l OFF ON OFF l ON ON OFF 0 l ON OFF ON l OFF ON ON 90 l ON ON ON Explanations: ON = bridge closed OFF = bridge open = factory setting For the meaning of the measring sockets, and display and adjstment elements (potentiometer) on the front plate, see page 9. Bosch Rexroth AG, RE 0, edition: 0-0 Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

9 + (0) Control electronics VT 0 9/0 Front plate: Display and adjstment elements, measring sockets VT 0-X/-0 VT 0-X/-0 VT 0-X/-0 Ub p-control Ub p-control Ub p-control En. -control En. -control En. -control Err. FE-contr. Err. FE-contr. Err. Power Limiter R R R R R R R VT0 VT0 VT0 LED displays Ub (green) Spply voltage available En. (green) Enable available Err. (red) Falt/collective error p-control (yellow) Pressre control enabled -control (yellow) Swivel angle control enabled FE contr. (yellow) Pressre controller disabled Power Limiter (yellow) Power limitation active Adjstment elements (potentiometer) R Zero point of actal pressre vale R Actal pressre vale amplification R Setting of the power limit Zero point of actal valve vale Zero point of actal swivel angle vale Amplification of actal swivel angle vale Measring sockets (R i = kω) Pressre command vale 0 +0 V Actal pressre vale 0 +0 V Swivel angle command vale ±0 V Actal swivel angle vale ±0 V Valve command vale ±0 V Actal valve vale ±0 V Active swivel angle command vale ±0 V 8 Power limit 0 +0 V Reference for measred vales Reference for measred vales Display (measring instrment) Display of actal swivel angle vale in % RE 0, edition: 0-0, Bosch Rexroth AG Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

10 + (0) /0 VT 0 Control electronics Dimensions (dimensions in mm) VT 0-X/-0 VT 0-X/()- Ub p-control Ub p-control En. -control En. -control Err. FE-contr. Err. Power Limiter HE (8,) R R R R R VT0 VT0 TE (0,) 8TE (0,) 8 This docment, as well as the data, specifications and other information set forth in it, are the exclsive property of Bosch Rexroth AG. It may not be reprodced or given to third parties withot its consent. The data specified above only serve to describe the prodct. No statements concerning a certain condition or sitability for a certain application can be derived from or information. The information given does not release the ser from the obligation of own jdgment and verification. It mst be remembered that or prodcts are sbject to a natral process of wear and aging. Bosch Rexroth AG, RE 0, edition: 0-0 Hyqip Limited New Brnswick Street Horwich Bolton Lancashire BL JB UK

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump External control electronics for the SYDFE control of the A0VSO axial piston variable displacement pmp Type VT 504 RE 04 Edition: 0-06 Replaces:. Component series X Analog, Ero-card format Part of the

More information

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump External control electronics for the SYDEF adjstment of the A0VSO axial piston pmp RE 04/0.0 Replaces: 04 /0 Type VT 504-X/... Component series X H09_d Table of contents Content Page Featres Ordering code

More information

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable External control electronics for the SYDFE control of A0VSO axial piston pmps Analoge amplifier, configrable RE 04/0.0 Replaces: 08.06 /8 Type VT 504 From Component series 5 H685_d Table of contents Contents

More information

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE Analoge amplifier modles for 4/3 and 4/ proportional directional valves 4WRE RE 309/06.05 Replaces:.04 /0 Types VT-MRPA and VT-MRPA Component series X H677 Table of contents Contents Page Featres Ordering

More information

Electric amplifier for flow control with proportional

Electric amplifier for flow control with proportional Electric amplifier for flo control ith proportional valves RE 29955/07.14 Replaces: 09.11 1/8 Type VT 5035 Component series 1X H5581 Table of contents Content Page eatures 1 Ordering code 2 unctional description

More information

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents Valve amplifier for proportional directional valves and proportional pressure valves Type VT-VSPA2-1 RE 30110 Edition: 2013-04 Replaces: 05.12 Component series 2X Analog, euro-card format Suitable for

More information

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05 Valve amplifier for proportional directional valves Type VT-VRPA RE 0119 Edition: 01-0 Replaces: 07.05 Component series 1X Analog, Euro-card format Suitable for controlling / proportional directional valves

More information

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6 Analogue amplifier RE 29980/09.05 Replaces: 02.03 1/6 Type VT-SR2 Series 1X H5658 Table of contents Contents Page eatures 1 Ordering code 2 unctional description 2 Technical data 3 Block circuit diagram

More information

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated

More information

p/q closed-loop control amplifier

p/q closed-loop control amplifier p/q closed-loop control amplifier RE 30134 Edition: 2017-05 Replaces: 06.12 1/12 Type VT-VACA-500-2X/V0/... Component series 2X Table of contents Contents age Features 1 Ordering code, accessories 2 Front

More information

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional valves with electrical position feedback Valve amplifier for proportional valves with electrical position feedback Type VT-MRPA1-... RE 30221 Edition: 2015-02 Replaces: 2013-08 Component series 1X Analog, modular design Intended for controlling

More information

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X Analog amplifier RE 29926/10.06 Replaces: 0.03 /8 Type VT 3006 Component Series 3X H4240_d Table of contents Contents Page eatures 1 Ordering code 2 unctional Description 2 and 3 Block circuit / pin allocation

More information

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces: Valve amplifier for proportional valves Type VT-MSPA2-1 RE 30228 Edition: 2014-01 Replaces: 2011-04 Component series 1X Suitable for controlling direct operated proportional directional valves without

More information

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves Valve ampliier or proportional pressure valves Type VT-VSPA1-2 RE 30115 Edition: 2013-09 Replaces: 2013-02 Component series 1X Analog, Euro-card ormat Suitable or controlling proportional pressure valves:

More information

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6 Electric amplifiers RE 30052/02.12 Replaces: 01.09 1/6 Type VT-VRPA1-5...-1X/V0/... Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram

More information

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features Valve amplifier for high-response valves Type VT-VRRA1-527-2X/V0/2STV, VT-VRRA1-527-2X/V0/PO-IS RE 30045 Edition: 2013-04 Replaces: 02.12 Component series 2X Analog, euro-card format Suitable for controlling

More information

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6 Electric amplifiers RE 30048/08.12 Replaces: 03.12 1/6 Type VT-VRPA2-5...-1X/V0/RTP Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram

More information

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8 Plug-in amplifier RE 30264/07.12 Replaces: 03.10 1/8 Type VT-SSPA1 Component series 2X Table of contents Contents Page Features 1 Ordering code, accessories 2 Function 3 Connections and adjustment 3 Block

More information

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6 Electric amplifiers RE 30054/03.12 Replaces: 01.09 1/6 Type VT-VRPA1-5...-1X/...-RTP Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram

More information

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces: Valve amplifier for proportional valves Type VT-SSPA- (5, 50, 00, 50) RE 306 Edition: 05-03 Replaces: 04-07 Component series X Analog, connector design Suitable for controlling solenoid-actuated pressure

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29035 Edition: 2017-04 Replaces: 2015-02 Size 6 Component series 2X Maximum

More information

Electric amplifier for proportional cartridge throttle valves

Electric amplifier for proportional cartridge throttle valves Electric amplifier for proportional cartridge throttle valves RE 30053/09.05 1/8 Type VT-VRPA1-527-2X/V0/RTS-2/2V Unit series 2X List of contents Contents Page Features 1 Ordering data 2 Preferred types

More information

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6 Booster amplifier RE 30260/04.12 Replaces: 08.11 1/6 Type VT-MSFA1 Component series 1X H7924 Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block diagram / pinout 3

More information

RA / /6. Replaces: Table of contents RA /06.98

RA / /6. Replaces: Table of contents RA /06.98 Electronic amplifier for the control of proportional directional ales with electrical position feedback Models VT 5024 and VT 5025, Series 1X RA 29 958/06.98 Replaces: 11.97 The amplifiers VT 5024 and

More information

SENSOR TECHNOLGY APPLICATIONS FOR MEDIUM VOLTAGE

SENSOR TECHNOLGY APPLICATIONS FOR MEDIUM VOLTAGE 1(8) SENSOR TECHNOLGY APPLICATIONS FOR MEDIUM VOLTAGE )** Athor & Presenter: Bo Westerholm B.Sc. Prodct development engineer, ABB Oy, Medim Voltage Technology 1. Introdction Sensors are a new soltion for

More information

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6 Electric amplifiers RE 30052/08.05 Replaces: 05.04 1/6 Type VT-VRPA1 Unit series 1X List of contents Contents Page Features 1 Ordering data 2 Preferred types 2 Front panel 3 Circuit diagram with pin assignment

More information

Analog amplifier RA. RE Edition: Replaces:

Analog amplifier RA. RE Edition: Replaces: Analog amplifier RA RE 950 Edition: 08.05 Replaces: 0.006 For control of simple functions of electrohydraulic components Two power outputs (PWM) and one switching output Each output has a separately adjustable

More information

PRS xpxxx and LBB 4428/00 Power Amplifiers

PRS xpxxx and LBB 4428/00 Power Amplifiers Commnications Systems PRS xpxxx and Power Amplifiers PRS xpxxx and Power Amplifiers 1, 2, 4, or 8 adio otpts (selection from 100 / 70 / 50 V otpts) Adio processing and delay for each amplifier channel

More information

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Electronic Amplifier Model T 301 and T 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Replaces: 09.94 Electronic amplifier

More information

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Analog Amplifier RA RE 95 230/03.06 1/12 replaces: RE 95 022 RE 95 023 RE 29 874 RE 29 875 Technical Data

More information

RT-5005/5006/5007/5008

RT-5005/5006/5007/5008 Replaces: 09.12 Electro-hydraulic Control Digital Proportional Amplifier Type: RT-5005/5006/5007/5008 Series: 3X Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block

More information

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6 Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Electric amplifiers RA 30052/05.04 1/6 Model VT-VRPA1 Series 1X Table of contents Contents Page Features

More information

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

High-response valve with integrated digital axis controller (IAC-R) and field bus interface High-response valve with integrated digital axis controller (IAC-R) and field bus interface RE 99/09.0 Replaces: 06.05 / Type 4WRPNH.../4C... Type 4WRPNH.../4P... Size 6 and 0 Component series X Maximum

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

4/3 proportional directional valve direct operated, with integrated electronics

4/3 proportional directional valve direct operated, with integrated electronics 4/ proptional directional valve direct operated, with integrated electronics RE 2964/. Replaces: 2.2 /6 Type 4WREEM Sizes 6 and Component series 2X Maximum operating pressure 5 bar Maximum flow: 9 l/min

More information

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features. 4/ proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF RE 9048 Edition: 0-0 Replaces:. Sizes 6 and 0 Component series X Maximum operating pressure

More information

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces: Replaces: 09.12 Electro-hydraulic Control Digital Proportional Amplifier Type: RT-VSPA2-50 Series: 3X Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block circuit diagram

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X RA 29 934/0.98 Electronic amplifier for the control of proportional valves without position control Model T 3024, Series 3X RA 29 934/2.9 The amplifier T 3024-3X is suitable for the control of pilot operated

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot

More information

DENISON HYDRAULICS Proportional Pressure Control Valves

DENISON HYDRAULICS Proportional Pressure Control Valves DENISON HYDRAULICS Proportional Pressure Control Valves Series 4VP01 Cetop 03 Publ. 3-EN 2200-B, replaces 3-EN 2200-A FEATURES, SYMBOLS x FEATURES Direct operated pressure relief valve for flow up-to max.

More information

Proportional directional valves

Proportional directional valves 01/10 Proportional directional valves 6.12 Type 4WRPEH6...L2X NG 6 Up to 315 bar Up to 40L /min Contents Function and configuration 02 Ordering code 03 Symbols 03 Technical data 04 Electrical connection

More information

PowPak 20 A Receptacle Control Relay Module

PowPak 20 A Receptacle Control Relay Module PowPak Receptacle Control Relay Modle The PowPak Relay Receptacle Control Modle is a radio-freqency (RF), receptacle switching soltion that is capable of controlling receptacles based on inpt from Pico

More information

AxCent Servo Drive A50A100

AxCent Servo Drive A50A100 Description Power Range The A50A100 PWM servo drive is designed to drive brushed type DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type WRPEH RE 9 Edition: 8- Replaces: 7-5 Size 6 Component series 3X Maximum operating pressure

More information

Analog Servo Drive 30A8

Analog Servo Drive 30A8 Description Power Range The 30A8 PWM servo drive is designed to drive brush type DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected

More information

Digital amplifier for proportional valves PEM XD

Digital amplifier for proportional valves PEM XD Digital amplifier for proportional valves PEM XD FEATURES - Amplifier for cap rail mounting according to DIN EN 50022 - Control of 2 coils in open loop, or 2 proportional valves with 1 coil in open loop

More information

FEATURES APPLICATIONS TYPICAL APPLICATION. LTC1451 LTC1452/LTC Bit Rail-to-Rail Micropower DACs in SO-8 DESCRIPTION

FEATURES APPLICATIONS TYPICAL APPLICATION. LTC1451 LTC1452/LTC Bit Rail-to-Rail Micropower DACs in SO-8 DESCRIPTION 12-Bit Rail-to-Rail Micropower DACs in SO-8 FEATRES 12-Bit Resolution Buffered True Rail-to-Rail Voltage Output 3V Operation (LTC1453), I CC : 250µA Typ 5V Operation (), I CC : 400µA Typ 3V to 5V Operation

More information

TYPICAL APPLICATIO. LT MHz, 250V/µs, A V 4 Operational Amplifier DESCRIPTIO FEATURES APPLICATIO S

TYPICAL APPLICATIO. LT MHz, 250V/µs, A V 4 Operational Amplifier DESCRIPTIO FEATURES APPLICATIO S 5MHz, 5V/µs, A V Operational Amplifier FEATRES Gain-Bandwidth: 5MHz Gain of Stable Slew Rate: 5V/µs Input Noise Voltage: nv/ Hz C-Load TM Op Amp Drives Capacitive Loads Maximum Input Offset Voltage: µv

More information

Analog Servo Drive 20A20

Analog Servo Drive 20A20 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

AxCent Servo Drive A25A100

AxCent Servo Drive A25A100 Description Power Range The A25A100 PWM servo drive is designed to drive brush type DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected

More information

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches

More information

Analog Servo Drive 30A8

Analog Servo Drive 30A8 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Accessories Power Amplifiers

Accessories Power Amplifiers Front Panel Vickers Models with Command Logic Module and Ramps EEA-PAM-5**-B- Series General Description Features and Benefits The EEA-PAM-5**-B- Eurocards are power amplifiers with a four-input (demand

More information

Perfection in all dimensions

Perfection in all dimensions 44 55 60 S c a n w i d t h Perfection in all dimensions Optical resoltion 2400 x 1200 dpi Scan and mlti-fnctional soltions Made in Germany Perfection in all dimensions 44 55 60 S c a n w i d t h The sets

More information

Analog Servo Drive 25A20DD

Analog Servo Drive 25A20DD Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Energy Measuring Unit MODEL EMU4-FD1-MB. User s Manual (Details)

Energy Measuring Unit MODEL EMU4-FD1-MB. User s Manual (Details) Energy Measring nit MODE EM4-FD-MB ser s Manal (Details) Before operating the instrment, yo shold first read thoroghly this operation manal for safe operation and optimized performance of the prodct. Delier

More information

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options. Description Power Range The PWM servo drive is designed to drive brushless DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected against

More information

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939) TECHNICAL DATASHEET #TDAX022000 Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference (SAE J1939) Features: 1 universal signal input 2 proportional or on/off outputs up to 3 A User

More information

Analog Servo Drive 30A20AC

Analog Servo Drive 30A20AC Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Proportional amplifier type EV22K5

Proportional amplifier type EV22K5 Proportional amplifier type EV22K5 Assembly instructions Card design Supply voltage UB: Output current QA max: 9...32 V DC 1.8 A by HAWE Hydraulik SE. The forwarding and reproduction of this document,

More information

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation B25A20FAC Series B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation FEATURES: All connections on front of amplifier Surface-mount technology Small size, low cost,

More information

A Novel Concept for Mains Voltage Proportional Input Current Shaping of a VIENNA Rectifier Eliminating Controller Multipliers

A Novel Concept for Mains Voltage Proportional Input Current Shaping of a VIENNA Rectifier Eliminating Controller Multipliers 1 of 10 A Novel Concept for Mains Voltage Proportional Inpt Crrent Shaping of a VIENNA Rectifier Eliminating Controller Mltipliers Part I: Basic Theoretical Considerations and Experimental Verification

More information

DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION. LT1039A/LT1039A-16 Triple RS232 Driver/Receiver with Shutdown

DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION. LT1039A/LT1039A-16 Triple RS232 Driver/Receiver with Shutdown FEATRES On-Chip ESD Protection: ±15kV Human Body Model ±15kV IEC-00-4-2 Air Gap Test** ±8kV IEC-00-4-2 Contact Test 125kBd Operation with 3kΩ/2500pF Load 250kBd Operation with 3kΩ/00pF Load Operates from

More information

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5. 89 251/217 ED EDM-M* DIGITAL AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES EDM-M1 single solenoid EDM-M2 double solenoid EDM-M3 two single solenoids independent channels RAIL MOUNTING TYPE: DIN EN 50022

More information

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013 4-Way Servo Valve Model 4 WS. 2 E. 16..., (Series 2X) with Mounting attern to DIN 24 3 or CETO R 11 H Size 16... 40 SI (31 bar)... 3 GM (0 L/min) R 29 91/06.98 R 29 91/06.98 Replaces: 0.94 2 stage servo

More information

PowPak 20 A Relay Module

PowPak 20 A Relay Module PowPak 20 A Relay Modle The PowPak 20 A Relay Modle is a radio-freqency (RF), receptacle switching soltion that is capable of controlling 20 A receptacles based on inpt from Pico wireless controls and

More information

MODEL 7225X2 DUAL LINE-ISOLATED AC BRUSHLESS SERVO AMPLIFIER WITH +/-10V ANALOG U-V INPUTS

MODEL 7225X2 DUAL LINE-ISOLATED AC BRUSHLESS SERVO AMPLIFIER WITH +/-10V ANALOG U-V INPUTS MODEL X WITH /0 ANALOG INPTS FEATRES Two independent amplifiers in one package drive two phase AC brushless motors with sinusoidal commutation Compatible with controllers that output /0 analog torque commands

More information

DESCRIPTIO. LT1413 Single Supply, Dual Precision Op Amp

DESCRIPTIO. LT1413 Single Supply, Dual Precision Op Amp Single Supply, Dual Precision Op Amp FEATRES Single Supply Operation: Input Goes Below Ground Output Swings to Ground Sinking Current No Pull-Down Resistors Needed Phase Reversal Protection At V, V Low

More information

Distributed by: www.jameco.com --3-44 The content and copyrights of the attached material are the property of its owner. MHz, 3nV/ Hz, A V Operational Amplifier FEATRES Gain-Bandwidth: MHz Gain of Stable

More information

Protection class IP67/IP69K Magnetic measurement principle

Protection class IP67/IP69K Magnetic measurement principle POSITILT PTAS2 Magnetic inclination sensor with analog output Magnetic inclination sensor in a 36 mm housing Protection class IP67/IP69K Magnetic measurement principle Outputs: Voltage 0.5... 4.5 V; 0.5...

More information

LBC 3210/00 Line Array Indoor/Outdoor Loudspeaker

LBC 3210/00 Line Array Indoor/Outdoor Loudspeaker Commnications Systems LBC 3210/00 Line Array Indoor/Otdoor Lodspeaker LBC 3210/00 Line Array Indoor/Otdoor Lodspeaker www.boschsecrity.com Extended listening area Excellent intelligibility of speech and

More information

LBC 3201/00 Line Array Indoor Loudspeaker

LBC 3201/00 Line Array Indoor Loudspeaker Commnications Systems LBC 3201/00 Line Array Indoor Lodspeaker LBC 3201/00 Line Array Indoor Lodspeaker www.boschsecrity.com Extended listening area Excellent intelligibility of speech and msic Uniform

More information

Electronically controlled proportional pressure regulating valves

Electronically controlled proportional pressure regulating valves Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..

More information

Service case with test unit for servo and proportional valves with integral electronics (OBE)

Service case with test unit for servo and proportional valves with integral electronics (OBE) Service case with test unit for servo and proportional valves with integral electronics (OBE) RE 29685/03.11 Replaces: 07.10 1/12 Type VT-VETSY-1 Series 1X H/A/D 5967/98 Table of contents Contents Page

More information

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( ) Magnetic Angle Sensor with Analog Output Magnetic Angle Sensor 0-360 Measurement range 0-360 Protection class IP67 Analog output Compact, low profile housing Non-contact with external position magnet Wear

More information

Analog Servo Drive 100A40

Analog Servo Drive 100A40 Description Power Range The 100A40 PWM servo drive is designed to drive brush type DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected

More information

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors Servo Amplifier -Quadrant PWM for Brushless DC-Servomotors Series BLD 010 Operating Instructions Index Chapter 1. Description 2. Illustration 3. Specification. Dimensions. Safety notes.1 Skilled personnel.2

More information

ALT2000 Advanced Line Tester

ALT2000 Advanced Line Tester ALT2000 Advanced Line Tester Fll Data Sheet VONAQ ALT2000 - Technical Data Sheet MAIN FUNCTIONS Signal Generator & Selective Level Meter - Fll programmable freqencies, impedances, filters, modality Atomatic

More information

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K Electro-Hydraulic -Way Directional Servo Valve Model WS 2 E. and WSE 2 E. (Series X) Size (D 5)... 6 PSI (5 bar)... 2 GPM (75 L/min) R 29 586/6.98 R 29 586/6.98 Replaces: 5.9 Features: Servo valve for

More information

DESCRIPTION FEATURES APPLICATIONS. LT1313 Dual PCMCIA VPP Driver/Regulator TYPICAL APPLICATION

DESCRIPTION FEATURES APPLICATIONS. LT1313 Dual PCMCIA VPP Driver/Regulator TYPICAL APPLICATION Dual PCMCIA VPP Driver/Regulator FEATRES Digital Selection of V, V CC, 12V or Hi-Z Output Current Capability: 12mA Internal Current Limiting and Thermal Shutdown Automatic Switching from 3.3V to Powered

More information

ELECTRONIC REGULATOR FOR OPEN LOOP

ELECTRONIC REGULATOR FOR OPEN LOOP Characteristics SINGLE CHANNEL DUAL CHANNEL 12 VDC / 24 VDC ± 10% Feeding voltage (stabilized) 12 VDC / 24 VDC ± 10% 10 30 VDC Feeding voltage (max) 10 30 VDC 40 W Max power absorption 40 W 2.8 A Output

More information

Sensor Modbus-Register

Sensor Modbus-Register Senor Modb-egiter Senor Modb-egiter 22DTH-..5.. Dct enor hmidity / temperatre 22UTH-..50X Otdoor enor hmidity / temperatre 22DTM-..5 Dct enor CO2 / hmidity / temperatre 22ADP-..5.. Differential prere enor

More information

LBC3201/00 Line array loudspeaker, 60W

LBC3201/00 Line array loudspeaker, 60W Commnications Systems LBC3201/00 Line array lodspeaker, 60W LBC3201/00 Line array lodspeaker, 60W www.boschsecrity.com Extended listening area Excellent intelligibility of speech and msic Uniform distribtion

More information

FEATURES TYPICAL APPLICATIO LTC MHz to 3GHz RF Power Detector. in SC70 Package DESCRIPTIO APPLICATIO S

FEATURES TYPICAL APPLICATIO LTC MHz to 3GHz RF Power Detector. in SC70 Package DESCRIPTIO APPLICATIO S 300MHz to 3GHz RF Power Detector in SC70 Package FEATRES Temperature Compensated Internal Schottky Diode RF Detector Wide Input Frequency Range: 300MHz to 3GHz Wide Input Power Range: 30dBm to 6dBm Buffered

More information

FEATURES DESCRIPTIO APPLICATIO S. LTC2050/LTC2050HV Zero-Drift Operational Amplifiers in SOT-23 TYPICAL APPLICATION

FEATURES DESCRIPTIO APPLICATIO S. LTC2050/LTC2050HV Zero-Drift Operational Amplifiers in SOT-23 TYPICAL APPLICATION FEATRES Maximum Offset Voltage of µv Maximum Offset Voltage Drift of nv/ C Noise:.µV P-P (.Hz to Hz Typ) Voltage Gain: db (Typ) PSRR: db (Typ) CMRR: db (Typ) Supply Current:.8mA (Typ) Supply Operation:.7V

More information

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939) Features: TECHNICAL DATASHEET #TDAX021610 Universal Input, Single Output Valve Controller CAN (SAE J1939) 1 universal signal input (voltage, current, resistive, PWM, frequency or digital) 1 output: proportional

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches

More information

LVDT. Inductive Position Transducer. SL Series. Key-Features:

LVDT. Inductive Position Transducer. SL Series. Key-Features: HM-1803 LVDT Inductive Position Transducer SL Series Key-Features: Content: - Measurement ranges 10...600 mm - External, or cable electronics with cable break detection - Linearity up to ±0.10 % of full

More information

Vive Wireless Receptacle With Clear Connect Technology Wireless Receptacle Control. 15 A Split Receptacle * 15 A Duplex Receptacle * White WH

Vive Wireless Receptacle With Clear Connect Technology Wireless Receptacle Control. 15 A Split Receptacle * 15 A Duplex Receptacle * White WH 3691034c 1 09.01.17 The is a radio-freqency (RF) receptacle switching soltion that is capable of controlling 15 A or 20 A split or dplex style receptacles when paired with Pico wireless controls and occpancy/vacancy

More information

LBC3200/00 Line array loudspeaker, 30W

LBC3200/00 Line array loudspeaker, 30W Commnications Systems LBC3200/00 Line array lodspeaker, 30W LBC3200/00 Line array lodspeaker, 30W www.boschsecrity.com Extended listening area Excellent intelligibility of speech and msic Uniform distribtion

More information

Protection class IP67/IP69K Magnetic measurement principle

Protection class IP67/IP69K Magnetic measurement principle POSITILT PTAS2 Magnetic inclination sensor with analog output Magnetic inclination sensor in a 36 mm housing Protection class IP67/IP69K Magnetic measurement principle Outputs: Voltage 0.5... 4.5 V; 0.5...

More information

DESCRIPTIO. LTC1446/LTC1446L Dual 12-Bit Rail-to-Rail Micropower DACs in SO-8

DESCRIPTIO. LTC1446/LTC1446L Dual 12-Bit Rail-to-Rail Micropower DACs in SO-8 Dual 12-Bit Rail-to-Rail Micropower DACs in SO-8 FEATRES Dual DACs with 12-Bit Resolution SO-8 Package Rail-to-Rail Output Amplifiers 3V Operation (LTC1446L): I CC = 65µA Typ 5V Operation (LTC1446): I

More information

Analogue Temperature Transmitter

Analogue Temperature Transmitter TE 19.01 Electrical Temperature Measurement Analogue Temperature Transmitter Configurable Ranges, Head Mounting for Pt100 Resistance Thermometers for Thermocouples Applications Plant construction Power

More information

Manual SCA-SS V /02 page 1

Manual SCA-SS V /02 page 1 Manual SCA-SS-30-06 V 0.9 09/02 page 1 SCA-SS-30-06 (30V, 6A) The servo amplifier SCA-SS-30-06 is a powerful servo amplifier for brushed DC motors with an output range up to 150 Watt. These operation modes

More information

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1. Controller ESSK 0 and ELSK 0 solid state electronics infinitely metering ergonomic design robust enclosure Proportional amplifier module ESSK 0. The ESSK 0 proportional amplifier is used to control the

More information

LBC 34xx/12 Horn Loudspeakers

LBC 34xx/12 Horn Loudspeakers Commnications Systems LBC xx/ Horn Lodspeakers LBC xx/ Horn Lodspeakers High efficien drivers Up to W ( power) Wide opening angle Excellent speech reprodction Simple power setting Bosch high-efficien horn

More information

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional Directional Control Valves Nominal sizes 16 and 25 Proportional Directional Control Valves Nominal sizes 16 and 25 Pilot operated, electrically adjustable Interface acc. to DIN 24 340 and ISO 4401 PN [p max. ] = 315 bar 7502968.06.01.06 Description Design

More information

Speed sensor DSA series 12

Speed sensor DSA series 12 Speed sensor DSA series 12 RE 95133 Edition: 01.2015 Replaces: 07.2014 Hall-effect sensor for contactless speed measuring For installation in axial piston units Two versions With two frequency signals

More information

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER TECHNICAL DATASHEET #TDAX020510 6 INPUTS, 5 OUTPUTS VALVE CONTROLLER Up to 6 Digital, Analog or PWM Command Inputs 5 Independent Proportional or On/Off Outputs 1 +5V, 100 ma Reference Voltage CAN (SAE

More information