Underwriters Labs (UL) Approved Barriers

Size: px
Start display at page:

Download "Underwriters Labs (UL) Approved Barriers"

Transcription

1 ISO 91 REGISTERED Underwriters Labs (UL) Approved Barriers Basic Safety and Operational Specifications for Zener (passive) I.S. Barriers Multiple Channel Barriers to Save Space and Simplify System Design Positive, Negative or AC Voltage Versions Plug-in Style to Simplify Installation, Commissioning, and Maintenance DIN Rail or Multi-barrier Surface mount Chassis Options Safest Design Style No Mechanical Circuit Breakers or Replaceable Fuses DESCRIPTION: The Ronan zener safety barriers are plug-in modules containing one to for channels. All I/O wiring connections are made on the chassis via compression screw terminals which accept up to 12 awg wire. The I.S. ground connection is via a #8 screw stud with self-locking nut, also located on the chassis. Optional ground buss bars are available to simplify grounding of cable shields or I.S. ground referenced return signals. SPECIFICATIONS: Type: shunt zener diode Chassis: Plug-in single or multi-barrier chassis (chassis is required for all barriers ) Mounting: surface mount (single or multiple barriers) or single DIN rail mount Wiring: all wiring and grounding is connected to terminals on the chassis Wire Size: up to #12 AWG (1. mm 2 ) Dimensions: 3.6 H X.88 W X 2. D (91.44mm X 22.3mm X 63. mm) Weight:.6 oz (24 gm) (chassis not included) Operating Temp.:-4ºF to 122ºF(-2 C to + C) Storage Temp.:-4ºF to 176ºF (-4 C to +8 C) Relative Humidity: 9% (non-condensing) Power: not required Ground: Intrinsic safety ground required Polarity Codes: P = Positive; N = Negative; A = AC; S = AC (star) Approval Agency: Class I, Grps A,B,C,D; Class II, Grps E,F,G; Class III Specifications apply at 23 +/- 2 C (74 +/- 2 F) unless otherwise specified, and are subject to change without notice. MECHANICAL DETAIL: A = connector protection/ alignment shroud B = chassis locking ears C = quick release tabs D = front access adjustments Page 1 of 6 Ronan Engineering Company Rev. 2 Ph: Fax: sales@ronan.com Web:

2 BASIC SAFETY AND OPERATIONAL VALUES: * Safety Values and Group ratings shown are typical for most applications. Refer to agency approved installation drawings for a complete listing of entity number values for your particular installation. Model Voc Isc Type end-end 1(1)µa V ma Group* X7-P,N 4. 3 A 2 +1; X7-17P,N A X7-19P,N A 126 (7) X7-11P,N A X7-116P,N A 132 (13.) X7-122P,N A 247 (18.2) 19.8 X7-128P,N A X7-128P6,N6 A X7-A. 274 B 26 +1; X7-11A B 126 (7) X7-117A 17. B 132 (13.) X7-123A B X7-129A B X7-22P C m +.6; X7-2P,N D 2m +1; X7-29P,N D 126 (7) X7-216P,N D 132 (13.) X7-222P,N D 226 (18.2) 19.8 X7-228P,N D X7-229P,N 28. D C - G X7-27A E X7-21A 9 8 E X7-212A E X7-212AA E X7-212AB E X7-2S. 267 F 29m +1.6; X7-21S F 26 (7.6) X7-217S 17. F 132 (14.1).4 1 X7-222S F X7-229S F m = channel matched (end-to-end) to +/-. Ω from 2 to 6C Haz. Side Safe Side Type A Type B Type C Type D Type E Type F See last page of this document for detailed definitions of terms. (continued on next page) Page 2 of 6 Ronan Engineering Company Rev. 2 Ph: Fax: sales@ronan.com Web:

3 Model Voc Isc Type end-end 1(1)µa V ma Group* X7-222PDD 22. G 2mA X7-228PDD 28. G 2mA X7-222PD, H 226/ ND 22. X7-228PD, ND mA H 331/ 2mA / 26. / / X7-227P I 331/ 26./ / 29P X7-228P I 226/ 26./ / C - G 29P X7-227P I 331/ 26./ / 29PR X7-228P I 226/ 26./ / C - G 29PR X7-3P,N J 2m +1; X7-39P,N J 126 (7) X7-31P J (7) X7-316P,N J 132 (13.) X7-322P,N J 247 (18.2) 19.8 X7-328P,N J X7-376P J 226/ 226/ / 7/ 7.1/ 8.6/ / / X7-4P,N K 2 +1; X7-49P,N K 126 (7) X7-411P,N 11.6 K X7-416P,N K 132 (13.) X7-422P,N K 226 (18.2) 19.8 X7-428P,N K X7-429P,N 28. K C - G m = channel matched (end-to-end) to +/-. Ω from 2 to 6C Note: a slash ( / ) separates channel values (i.e. Ch1/Ch2 etc.) Haz.. Side Safe Side Type G Type H Type I (With 2 Ω resistor) Type J Type K (continued on next page) Page 3 of 6 Ronan Engineering Company Rev. 2 Ph: Fax: sales@ronan.com Web:

4 Model Voc Isc Type end-end 1(1)µa V ma Group* X7-422PD X7-428PD X7-422PDD X7-428PDD L 226/ 226/ 2mA L 331/ 331/ 2 ma 112 M 226/ 2mA 1 M 331/ 2mA / / 26./ 26.2/ / 19.6/ / 26.2/ 26.2/ 26.2 Note: a slash ( / ) separates channel values (i.e. Ch1/Ch2 etc.) / / / / / / / 1/ 1/ 1 / 1/ 1/ 1 Haz. Side Safe Side Type L Type M Speciifications subject to change without notice. (continued on next page) Page 4 of 6 Ronan Engineering Company Rev. 2 Ph: Fax: sales@ronan.com Web:

5 SPECIFICATIONS: Type: zener diode (with Io limited) Chassis: Plug-in single or multi-barrier Mounting: surface or DIN rail chassis Wiring: all wiring is to chassis Wire size: up to 12 awg (1. mm 2 ) Operating Temp.: 2C to +C Storage Temp.: -4C to +8C Relative Humidity: 9% (non-cond.) Ground: I.S. ground required Supply Voltage: +1 to +3 vdc (Vs) UL Current Limiting Zener I.S. Barriers (continued) Supply current: <1 ma@24v (no load) Output Limit Current: <= 4 ma Barrier Voltage Drop: (approx.) X7-128PCL = (Io X 39) +.8V X7-122PCL = (Io X 24) +.8V X7-116PCL = (Io X 136) +.8V X7-228PCL = (Io X 428) + 1.V X7-222PCL = (Io X 323) + 1.V X7-216PCL = (Io X 194) + 1.V Load Current: (approx., not limited) X7-128PCL = (Vs.8) / (Rload+39) X7-122PCL = (Vs.8) / (Rload+24) X7-116PCL = (Vs.8) / (Rload+136) X7-228PCL = (Vs 1.) / (Rload+428) X7-222PCL = (Vs 1.) / (Rload+323) X7-216PCL = (Vs 1.) / (Rload+194) BASIC SAFETY AND OPERATIONAL VALUES: Model Voc Isc Type end-end 1 ma V ma Group* X7-116PCL N ma X7-122PCL N ma X7-128PCL N ma X7-216PCL.87/ / P /13. 3/14 1/1 X7-222PCL 21.16/ X7-228PCL 28.6/ / 1.3/ Output Voltage X7-128PCL X7-228PCL mA P mA P mA X7-122PCL 28/18. 3/19 / 28/2. 3/27 / Note: a slash ( / ) separates channel values (i.e. Ch1/Ch2 etc.) X7-222PCL Input Supply Voltage X7-116PCL X7-216PCL Rload open 7 3 Rload Output Barrier Input Power Supply (Vs) Test Circuit Haz. Side Safe Side Type N Type P Page of 6 Ronan Engineering Company Rev. 2 Ph: Fax: sales@ronan.com Web:

6 ORDERING INFORMATION: Barriers: Select barrier based on application and entity values. Chassis Options: X7-DIN single barrier chassis for 32 mm G style DIN rails X7-DIN-GB-( )... ground bar order one piece to connect two or more X7-DIN-32 chassis grounds. Order two pieces to connect redundant grounds or to use one or two X7-GCB s below. Number of Chassis to Connect X7-DIN-GCB... Ground Clamp Bars with (1) Ground Clamps per bar (order one or two) X7-DIN-3... single barrier chassis for 3 mm U style DIN rails X7-DIN3-GB-( )... ground bar order one piece to connect two or more X7-DIN-3 chassis grounds together. Included two Ground clamps per chassis and required hardware. Number of Chassis to Connect X7SM-1... single barrier surface mount chassis X7SM single barrier surface mount chassis with optional ground bar and four ground clamps X7SM-4 -( )-( )-( )... four (4) barrier surface mount chassis (gnd. bars & clamps optional) X7SM-1-( )-( )-( )... ten (1) barrier surface mount chassis (gnd. bars & clamps optional) X7SM-16-( )-( )-( )... sixteen barrier surface mount chassis (gnd. bars & clamps optional) X7SM-2-( )-( )-( )... twenty barrier surface mount chassis (gnd. bars & clamps optional) Qty of gnd. clamps on haz. side gnd. bar. (max qty. = 16 for SM-4, 4 for SM-1, 64 for SM-16; 8 for SM-2) or omit Qty of gnd. clamps on safe side gnd. bar. (max qty. = 16 for SM-4, 4 for SM-1, 64 for SM-16; 8 for SM-2) or omit 1= optional ground bar on safe side; 2= optional gnd. bar on haz. side; 3 = gnd. bars on both sides; omit if not needed Accessories: X7-GC... ground clamps X7-BLK... blank panel for unused chassis position D1-32x mm X mm G style DIN rail (order by the foot) D2-3x mm X. mm U style DIN rail (order by the foot) DEFINITIONS: Basic Safety Values Voc Isc The maximum open circuit voltage that can appear at the hazardous side barrier terminals The maximum current that can flow with hazardous side barrier terminals shorted to I.S. ground. Vmax Vwkg Rmax end-end Fuse Operational Values The maximum DC or Peak AC voltage (referenced to I.S. ground) that can applied to the safe side barrier terminals (with hazardous side terminals open circuited) without opening the barrier s fuse. Recommended maximum DC or Peak AC voltage (referenced to I.S. ground) that can be applied to the safe side barrier terminals (with hazardous side terminals open circuited) to meet a maximum leakage current of 1 µa or 1 µa as specified. The maximum resistance that can appear between the barrier s hazardous and safe side terminals. The fuse manufacturer s rating for maximum continuous current flow without opening the fuse. Page 6 of 6 Ronan Engineering Company Rev. 2 Ph: Fax: sales@ronan.com Web:

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web: -

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web:  - MZB SERIES Intrinsically Safe Shunt Diode Safety Barriers Turck of Intrinsically Safe Shunt Diode Safety Barriers New series of Zener Barriers include a wider product range for more flexibility in more

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa

More information

CEC VIBRATION TRANSMITTER

CEC VIBRATION TRANSMITTER CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:

More information

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE FOXCART 400 MARK II OPERATION AND SERVICE MANUAL MODEL PR2400-400 APPROX. 550POUNDS THE POWER CART WITH MUSCLE FOXTRONICS LOVE FIELD - DALLAS TEXAS MADE IN THE USA 3448 WEST MOCKINGBIRD LANE DALLAS, TEXAS

More information

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided

More information

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors. SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

200 Watt Passive Shunt Module

200 Watt Passive Shunt Module Installation Instructions 200 Watt Passive Shunt Module (Catalog Number 9101-1183) Drives can require external power dissipation when large inertial loads are present. To ensure that faults due to excessive

More information

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply. LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes

More information

Trusted Speed Monitor Input FTA (SIFTA)

Trusted Speed Monitor Input FTA (SIFTA) PD-T8846 Trusted Product Overview The Trusted Speed Monitor Input Field Termination Assembly (SIFTA) is a DIN rail assembly. It provides the input field interface for three rotating machine groups when

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

200 V channels 1-3 Common LO channel Maximum DCV Both 3030 V 202 V 40 V 42 V Maximum DCI 1. DC 122 ma A 4.5 A AC + DC 100 µa 100 µa

200 V channels 1-3 Common LO channel Maximum DCV Both 3030 V 202 V 40 V 42 V Maximum DCI 1. DC 122 ma A 4.5 A AC + DC 100 µa 100 µa Model 8020 Keithley Instruments High Power Interface Panel 28775 Aurora Road Instrument Specifications Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley SPECIFICATION CONDITIONS The Model

More information

General Specifications

General Specifications General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Trusted Versatile FTA

Trusted Versatile FTA PD-T8842 Trusted Product Overview The Trusted Versatile Field Termination Assembly (VFTA) T8842 is primarily designed to act as the main interface between field devices associated with the detection and

More information

Analog Servo Drive 25A20DD

Analog Servo Drive 25A20DD Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD Product Information Package PIP-CW ISProx Jul., 007 ControlWave ISProx Board ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD For ControlWave EFM/GFC/GFC Correctors Remote Automation Solutions

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

F2xx & F2xx-XE megablock range

F2xx & F2xx-XE megablock range Technical data MTL fieldbus networks September 0 EPS Fxx rev Fxx & Fxx-XE megablock range Passive hubs for zone & division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation

More information

Trusted Power Distribution Unit MCB 24 Vdc

Trusted Power Distribution Unit MCB 24 Vdc PD-T8292 Trusted Trusted Power Distribution Unit MCB 24 Vdc Product Overview The dual 5-channel Trusted Power Distribution Unit Miniature Circuit Breaker (MCB) 24 V is designed for N+1 or 100 % redundant

More information

24V dc Analog Block I/O Module

24V dc Analog Block I/O Module 24V dc Analog Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module. Refer

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT Instruction Manual T-800 Series Current Transmitter Model T-800L Model T-800LT Model T-800TT M323 Rev G1 September 10, 2009 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Telephone: 978-486

More information

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER A. GENERAL DESCRIPTION The Tegam Model RH is a relative humidity transmitter; the Model RHT includes a temperature

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox 40 Series Cryogenic Temperature Sensor Input Modules 40 Series modules are the ideal companion to Cernox Model 40-P For smaller installations and high-speed measurements Updates readings as fast as ms

More information

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2VF MODEL: M2VF [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 October 2017 RSTI-EP Slice I/O Specialty Modules EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 Module Status LED Channel Status LED GE provides several RSTi-EP specialty modules, which

More information

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V 20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor

More information

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models HT880 and HT885 are 2-wire temperature

More information

Installation Instructions

Installation Instructions Installation Instructions ControlNet Modular Repeater Dual Copper Module Catalog Number This document describes how to install and apply the dual copper repeater module. Topic: Page: Important User Information

More information

Resistance Temperature Device Conversion Module

Resistance Temperature Device Conversion Module No.SS2-2330-0350 (Rev. 1) SystempaK (Digital/Single Case) Resistance Temperature Device Conversion Module Model J-SRP 90/95 Introduction The Resistance Temperature Device (RTD) Conversion Module (J-SRP)

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC Properties 1 Parameters 2 Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) Manual

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

Voltage Adjustment. Load Regulation

Voltage Adjustment. Load Regulation HIGH DENSITY, CONFIGURABLE AC-DC POWER SUPPLY RCB1200 SERIES DS RCB1200 RE02 NOEMBER 2010 Description The RCB1200 is a modular, user configurable power supply offering unrivalled performances and flexibility.

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

Measuring current transformers of the W AB(P) series

Measuring current transformers of the W AB(P) series Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017 Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

XIOC technology and networking modules

XIOC technology and networking modules / XIO XIO digitale and analog input/output modules XIO technology and networking modules XIO the compact I/O and much more XIO are local expansion modules for direct connection to all Xontrol controllers.

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options. Description Power Range The PWM servo drive is designed to drive brushless DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected against

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

1715 Redundant I/O System Specifications

1715 Redundant I/O System Specifications Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications

More information

User and Safety Manual ProLine P224xx P1

User and Safety Manual ProLine P224xx P1 The Art of Measuring. User and Safety Manual ProLine P224xx P1 English 17 Loop-Powered Isolators/Splitters www.knick-international.com Contents 17 Safety Information 18 Short Description 19 Intended Use

More information

Signet 2750 DryLoc ph/orp Sensor Electronics

Signet 2750 DryLoc ph/orp Sensor Electronics Signet 2750 DryLoc ph/ Sensor Electronics Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or operation In-line 2750 Submersible

More information

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual ) ) ) ) ) ) ) ) ) ) ) ) Notice: These devices must be wired in accordance

More information

Technical Information Barrier RB223

Technical Information Barrier RB223 TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

Analog Servo Drive 30A20AC

Analog Servo Drive 30A20AC Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile

More information

PHOENIX CONTACT

PHOENIX CONTACT Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24

More information

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany 522 WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany WAGO Products: WAGO-I/O-SYSTEM with ETHERNET Controllers, DALI and EnOcean Components Wireless Technologie System Overview 524

More information

Railbus isolator. Railbus isolator 8922-RB-IS

Railbus isolator. Railbus isolator 8922-RB-IS Railbus isolator Railbus isolator 8922-RB-IS provides galvanic isolation between Railbus sections prevents fault-voltage invasions protects IS field wiring modules See also System Specification Dimensions

More information

AxCent Servo Drive A50A100

AxCent Servo Drive A50A100 Description Power Range The A50A100 PWM servo drive is designed to drive brushed type DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),

More information

WORLD-BEAM QS18AF Sensor with Background Suppression

WORLD-BEAM QS18AF Sensor with Background Suppression WORLD-BEAM QS8AF Sensor with Background Suppression Datasheet Compact sensors featuring extended range and background suppression mode Exceptional optical performance; up to 00 mm sensing range in compact

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

Seismometer Preamplifier Manual

Seismometer Preamplifier Manual Seismometer Preamplifier Manual Seismometer Preamplifier Manual Part number Revision Date Description 13867 1.0 2001-12-18 Initial release Seismometer Preamplifier - Table of Contents 1 Introduction...

More information

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS232 7. June 2011 w w w. p a p o u c h. c o m Q uidoduplex RS Datasheet Created: 3/16/2006 Last update: 6/7/2011 8:57 AM Number

More information

SHORT-FORM DATA MARKINGS. IECEx

SHORT-FORM DATA MARKINGS. IECEx MOSFET REDUNDANCY MODULE Single with Single Equipped with Plug-connector for Hot Swapping Suitable for all DIMENSION Power Supplies Except QT40 Series Only 150mV Voltage Drop at 40A Only 6.2W at 40A 160%

More information

Metal Case Power Supplies

Metal Case Power Supplies , 120 480 Watt Features Compact U-bracket and enclosed power supplies Screw terminal block Very high efficiency up to 93 % No internal fan for 120 W & 240 W models. Universal input 90 264 VAC Adjustable

More information

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions Overview and Identification The BAPI-Stat 4 X-Combo () Room Unit features 4 output channels and optional local indication of temperature and humidity. Additional options include Temperature Setpoint, Humidity

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel

More information

1715 Redundant I/O System Specifications

1715 Redundant I/O System Specifications Technical Data 1715 Redundant I/O System Specifications System Module Catalog Numbers 1715-AENTR, 1715-IB16D, 1715-OB8DE,1715-IF16, 1715-OF8I Base Unit Catalog Numbers 1715-A2A, 1715-A3IO Termination Assembly

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE TAD 65 U B - xx yy - Series Name Output Input Output Output Output Output Output Protection

More information

FRONT BUMPER KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

FRONT BUMPER KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6 FRONT BUMPER KIT P/N 2882301 APPLICATION Verify accessory fitment at Polaris.com. BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please retain these

More information

DET-TRONICS SPECIFICATION DATA. Eagle Quantum Premier 8 Channel Enhanced Discrete Input/Output Module (EDIO) EQ3730EDIO DESCRIPTION

DET-TRONICS SPECIFICATION DATA. Eagle Quantum Premier 8 Channel Enhanced Discrete Input/Output Module (EDIO) EQ3730EDIO DESCRIPTION DET-TRONICS SPECIFICATION DATA Eagle Quantum Premier 8 Channel Enhanced Discrete Input/Output Module (EDIO) EQ70EDIO DESCRIPTION The 8 Channel EDIO Module is specially designed to expand the Input and

More information

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Cable transducer Analog output / redundant Measuring length absolute up to 5 m Features Magnetic sensing method Resolution: 12 bit Interface analog 0...10 V / 0.. V /...20 ma Measuring length up to m Removable stickers for water outlet Teach inputs Extremely light thanks to housing

More information

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series USER'S MANUAL ACD-6 Pro ACD-6 TRMS Pro Versatile Clamp-on Multimeter Series 1 1) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining

More information

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)

More information

GTS High Frequency Pulser. Technical Bulletin

GTS High Frequency Pulser. Technical Bulletin GTS High Frequency Pulser Technical Bulletin 02 Elster American Meter High Frequency Pulser System control and data acquisition in gas distribution networks begins with process sensors: sensors to detect

More information

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase Introduction ISOLATD SIGNAL CONDITIONING can significantly increase your system reliability here's how: Linearizes Thermocouple and RTD signals Reduces the demands on the software to linearize the signal

More information

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features Hexa Multi Module Introduction The E-Plex 366HMM is a six channel DC power distribution module capable of handling loads of up to 15A per channel or 50A total. The six channels can be utilized as either

More information

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC. DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC. MODEL SELECTION GUIDE The DIN Series of Digital Panel Meters are rugged low cost meters for the measurement of dc voltage, dc current, Process voltage

More information

MTL7700 range DIN-rail mounting safety barriers

MTL7700 range DIN-rail mounting safety barriers Technical data MTL intrinsic safety solutions September 07 EPS7700 Rev MTL7700 range DIN-rail mounting safety barriers Removable terminals feed to other modules Relay and solid state switch modules Dual

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

Active UTP Transceiver Hub Installation Guide

Active UTP Transceiver Hub Installation Guide Active UTP Transceiver Hub Installation Guide Models Include: HubWayLDH8 HubWayLDH16 - UL Listed eight (8) Channels - UL Listed sixteen (16) Channels Rev. 032108 More than just power. TM Overview: Altronix

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Analog Servo Drive 20A20

Analog Servo Drive 20A20 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information