Improving Distribution Circuit Performance without Circuit Rebuilds. John Lauletta, CEO

Size: px
Start display at page:

Download "Improving Distribution Circuit Performance without Circuit Rebuilds. John Lauletta, CEO"

Transcription

1 Improving Distribution Circuit Performance without Circuit Rebuilds John Lauletta, CEO

2 Maintenance Strategies Reliability Centered Maintenance Reactive Maintenance (Run To Failure) Preventive Maintenance (Time Based) Predictive Maintenance (Conditions Based) Proactive Maintenance (Improvement) Small, non critical items Inconsequential, not likely to fail Redundant Subject to wear Consumable Known failure pattern Random Failure Pattern Not Subject to wear PM Induced Failures Root Cause Failure Analysis (RCFA) Failure Mode Effects Analysis (FMEA)

3 Predictive Maintenance (PdM) To use data from an entire process to find any measurable characteristics that may serve to warn that these detrimental situations are approaching. PdM techniques are designed to help determine the condition of inservice equipment in order to predict when maintenance should be performed. This approach promises cost savings over routine or time-based preventive maintenance, because tasks are performed only when warranted. PdM inspections are performed while equipment is in service, thereby minimizing disruption of normal system operations. Adoption of PdM can result in substantial cost savings and higher system reliability.

4 Predictive Maintenance (PdM) RF Emission Grid Inspection Ultrasonic Detection Infrared Detection Visual Inspection

5 Impacts of Maintenance Strategies Periodic/Preventive Maintenance Failure Rate Predictive Maintenance Early Failure Period Constant Failure Period Wear-out Failure Period

6 PdM How? To evaluate equipment condition, predictive maintenance utilizes non-destructive testing technologies such as infrared photography, ultrasonic acoustic, radio frequency (RF) emissions, corona detection, vibration analysis, sound level measurements, oil analysis, and other specific online tests.

7 PdM Why? Benefits of PdM Strategies Maintenance costs - down by 50% Unexpected failures - reduced by 55% Repair and overhaul time - down by 60% Spare parts inventory - reduced by 30% 30% increase in machinery MTBF 30% increase in uptime

8 Applying a PdM Strategy to the Grid 1. Assess System Condition 2. Schedule Maintenance 3. Measure Results 4. Repeat Process

9 U.S. Non Weather-Related Outages on the Electric Distribution System 31% of outages are caused by failing equipment 32% of outages are caused by trees Data Source: Miscellaneous 19% Animals 18%

10 Maintenance Techniques 31% of outages are caused by failing equipment 32% of outages are caused by trees Miscellaneous 19% Animals 18% Data Source:

11 Detecting Equipment Failure Device Insulator Failure Mechanism Internal Damage Contamination External Damage Dry Band Arcing Leakage Tracking Failure Detection Technology RF US-AC IR Failure Mechanism

12 Detecting Equipment Failure Device Lightning Arrester Failure Mechanism MOV Damage Contamination External Damage Dry Band Arcing Leakage Tracking Failure Detection Technology RF US-AC IR

13 Detecting Equipment Failure Device Cutout Failure Mechanism Internal Damage Contamination External Damage Dry Band Arcing Leakage Tracking Failure Detection Technology RF US-AC IR

14 Detecting Equipment Failure Device Transform er Bushing Damage Contamination Internal Arcing Low Oil Failure Detection Technology RF US-AC IR Failure Mechanism

15 Detecting Equipment Failure Use Technologies that measure specific failure symptoms Apply Technologies in most cost-effective manner Manage conditions-based analytics for proactive maintenance action Technical Tutorials

16 Utility Experience with PdM Programs Case Studies

17 Case Study: PG&E (EEI TD&M, Oct, 2016)

18 Case Study: UNITIL (T&D World, Oct. 2015)

19 Case Study: COSERV (RE Magazine, Oct. 2016)

20 Process & Technologies Exacter s predictive process utilizes two technologies and proprietary analysis to identify non-temporary & consistent, problematic conditions that are related to the overhead electric system Predictive Process 1. Patented Radio Frequency (RF) Technology Captures PD & EMI emissions present in the field Correlates emissions with GPS location 2. Proprietary Analysis (Failure Signature Library) Analyzes and discriminates field data to identify specific structures where arcing, leaking, & tracking are present 3. Ultrasonic Acoustic Technology Field Engineers visit identified structure Pinpoint component responsible for problematic conditions

21 Process & Technologies Exacter Radio Frequency Assessment Data collection Capture Partial Discharge & EMI Correlate with GPS Multiple passes Non-temporary Consistent Failure Signature Analysis Analyze & Discriminate Field Data Identify emissions related to overhead system Specific location where PD/EMI is present

22 Exacter Process & Technologies The 1,161 RED Failure Signature Events are captured by the EXACTER RF Assessment. The Failure Signature Analysis identified 77 BLUE Maintenance Groups where problematic conditions (PD/EMI) are present.

23 Exacter Process & Technologies Ultrasonic Field Locating Exacter Field Engineer visit identified structure Confirm presence of PD/EMI Identify specific component(s) responsible for problematic condition

24 Deteriorated Equipment Population (7 year, 2 million structure survey)

25 U.S. Lightning Density

26 Lightning Arrestors 0% Cutouts 6% Transmission Posts 14% formers 3% tors % Transformers 4% Insulators 4% Dead Ends 14% Regional Deteriorated Equipment Findings Mis 7% Lightning Arrestors 4% Cutouts 12% Insulators Deadends 4% 7% Misc HW 7% Transmission Posts 2% Transformers 2% Lightning Arrestors 7% Cutouts 3% Dead Ends 12% Misc HW 1% Grounds 2% Transformers 0% Insulators 0% Lightning Arrestors 17% Cutouts 2% Deadends 3% Misc HW 2% B Transmission Posts Pin Insulators 10% 55% ransformers 4% ulators 4% C Pin Insulators 69% Non-Utility n Insulators Trans Post Insulators 6% 2% 74% Pin Insulators 57% Dist nsulators 15% Lightning Arrestors 55% Pin Insulators 42% Dea 1 Misc HW 1% ors Dead Ends 4% Transformers 6% Ground 2% Lightning Arrestors Cutouts Ligh Dead Gro Ends Tra Misc HW Dea Pin Pin Insulators Dis Tra Insulators Non Transformers Transmission Posts

27 Hidden Damage No Protection

28 Obvious Physical Damage No Protection Deterioration

29 Laboratory Specimen Test Setup Arrester Under Test RF Emission Instrumentation Adjustable HV AC Source Antenna Array and Ground Plane

30 Comparing New and Deteriorated Arresters Current Sensing Resistor is 25 ohms Resistive voltage divider = 1000/1 Leading current is typical until cutoff voltage is reached 58 Field samples were reviewed New Specimen Deteriorated Specimen

31 RF Emission Spectrum Deteriorated Specimen Emission Spectrum Linear Frequency scale 0 to 1.5 GHz Historical and Instantaneous analysis shown

32 Demodulated RF Emission Analysis End of RF 0.56 MCOV Onset of Failure 0.67 MCOV Condition Signature Development Sensor correlates demodulated emission characteristics to failure signature

33 Case Study South Central U.S. Central Texas Service Territory 6 counties 190,000+ customers served 4,600 Distribution Miles 2,200 Overhead Miles 2,400 Underground Miles

34 Data Analysis: Historical Interruption Data The customer provided the most recent 12 months of interruption data October 1, 2013 September 30, 2014 Outage Cause CMI # of Interruptions % of CMI Equipment 1,619, % (Approx) IEEE Equipment Cause Codes: ** Excludes IEEE days for MEDs // Excludes Momentaries 300 Material or Equipment Failure 400 Decay/Age of Material or Equipment 410 Corrosion/Abrasion of Material or Equipment

35 Data Analysis: Exacter Pareto Analysis Exacter Analysis normalizes the dataset to allow for meaningful comparison of the circuits Divide Total EQ CMI / OH Miles for each circuit The new metric used to compare circuits is Equipment CMI / OH Mile Exacter ranks each circuit by the Equipment Related CMI / OH Mile Circuits with the highest Equipment CMI / OH Mile provide the greatest opportunity to improve performance and reliability

36 Data Analysis: Exacter Pareto Analysis Feeders that represent greatest opportunity for improvement

37 2015 Pilot Assessment Circuit Selection The pilot covers portions of 67 circuits totaling 180 miles of overhead distribution - The majority of overhead miles are 3-phase infrastructure - Eastern area of Service territory - High growth area The option has the opportunity to impact 993,338 equipment related customer minutes of interruption (CMI) - 29 Equipment related outages

38 2015 Pilot Assessment Area

39 2015 Pilot Assessment: Equipment Findings Survey Results

40 2015 Pilot Assessment: Component Finds Exacter assessment identified 1 component every 2.68 miles 3-phase overhead // co-located circuits // overbuild Density of service territory Presence of protective devices on system Exacter assessed 6,446 poles 180 assessed miles = 6,446 poles 67/6,446 = 1.03% of poles with problematic conditions 98.97% of assessed infrastructure does not have presence of problematic conditions

41 2015 Pilot Assessment: Field Report

42 2015 Pilot Assessment: Considerations & Conclusions May 2015: Wettest month on record for Dallas-Ft. Worth area 4.4 million lightning strikes More than 2013 or 2014 total Correlate lightning strike data with Exacter assessment Maintenance Operations for Identified Components Further Lightning Arrester investigation Identify use for Exacter assessments in future maintenance operations

43 Summary and Remaining Work Arresters are a critical component in electric grid equipment reliability Arresters are most deteriorated in areas of greatest need: Southeast/Northeast U.S. Visual damage is not typically apparent and does not necessarily indicate state of protection element RF emissions characterize deterioration that impacts performance In 58 samples, 57 showed deterioration of protective ability More field samples will be evaluated in laboratory conditions to optimize failure signature discrimination and source location for utility maintenance planning

Electrical Equipment Condition Assessment

Electrical Equipment Condition Assessment Feature Electrical Equipment Condition Assessment Using On-Line Solid Insulation Sampling Importance of Electrical Insulation Electrical insulation plays a vital role in the design and operation of all

More information

Load growth coupled with aging transform ers is a disaster wait ing to happen

Load growth coupled with aging transform ers is a disaster wait ing to happen RISK ASSESSMENT EVENTS Load growth coupled with aging transform ers is a disaster wait ing to happen 96 Jon L. GIESECKE Advanced transformer condition assessment Part I Transformer lifecycle and risk assessment

More information

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound Africa Utility Week Focus Day 2014 Substation Condition Monitoring Benefits of Ultrasound Agenda Review - Substation Condition Monitoring Electrical discharge Types and origin In switchgear Results/consequences

More information

SAMPLE. Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs.

SAMPLE. Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs. Keep Powering On SAMPLE Determining the health of your power transformer begins with Transformer Clinic s SAMPLE testing programs. Overheating, arcing, partial discharge, and other active or slow-evolving

More information

The Weidmann Conference The Aging of America s Transformers

The Weidmann Conference The Aging of America s Transformers The Weidmann Conference 2006 The Aging of America s Transformers by Jon L. Giesecke, Director, (610) 518-1615 jlgassociatesllc@yahoo.com How Old is Old? The aging of the electrical infrastructure in the

More information

Utility System Lightning Protection

Utility System Lightning Protection Utility System Lightning Protection Many power quality problems stem from lightning. Not only can the high-voltage impulses damage load equipment, but the temporary fault that follows a lightning strike

More information

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators

Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery Application of EMI Diagnostics to Hydro Generators James Timperley Doble Global Power Services Columbus, Ohio jtimperley@doble.com

More information

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology Condition Assessment of High Voltage Insulation in Power System Equipment R.E. James and Q. Su The Institution of Engineering and Technology Contents Preface xi 1 Introduction 1 1.1 Interconnection of

More information

ArresterFacts-002. Field Testing Arresters ArresterWorks.com. ArresterFacts are information modules pertaining to the arrester world.

ArresterFacts-002. Field Testing Arresters ArresterWorks.com. ArresterFacts are information modules pertaining to the arrester world. ArresterFacts are information modules pertaining to the arrester world. This Field Testing of Arresters module will clarify the many questions about assessing the quality of an installed high voltage arrester

More information

The Many Uses of Transmission Line Arresters

The Many Uses of Transmission Line Arresters Introduction It was not realized at the time, but the 1992 introduction of the polymer-housed transmission line arrester (TLA) was clearly a game changer in the practice of lightning protection of transmission

More information

Partial Discharge Theory, Modeling and Applications To Electrical Machines

Partial Discharge Theory, Modeling and Applications To Electrical Machines Partial Discharge Theory, Modeling and Applications To Electrical Machines V. Vahidinasab, A. Mosallanejad, A. Gholami Department of Electrical Engineering Iran University of Science and Technology (IUST)

More information

CRITICAL ISSUES WORST PERFORMING FEEDER PORTFOLIO

CRITICAL ISSUES WORST PERFORMING FEEDER PORTFOLIO EB-0-0 Exhibit D Tab 0 Schedule Page of CRITICAL ISSUES WORST PERFORMING FEEDER PORTFOLIO 0 0 THESL S WORST PERFORMING FEEDER PROGRAM THESL uses Customers Interrupted ( CI ) and Customer Hours Interrupted

More information

DEFERRING REPLACEMENT OF A 600 MVA, 345GRD Y/138GRD Y/ 13.8 kv SHELL TYPE WESTINGHOUSE AUTOTRANSFORMER

DEFERRING REPLACEMENT OF A 600 MVA, 345GRD Y/138GRD Y/ 13.8 kv SHELL TYPE WESTINGHOUSE AUTOTRANSFORMER DEFERRING REPLACEMENT OF A 600 MVA, 345GRD Y/138GRD Y/ 13.8 kv SHELL TYPE WESTINGHOUSE AUTOTRANSFORMER JESSE M LOPEZ CPS ENERGY USA EMILIO MORALES CRUZ QUALITROL USA SUMMARY Power transformers are essential

More information

APPLICATIONS OF ACOUSTIC LOCALIZATION TO ONLINE POWER TRANSFORMERS

APPLICATIONS OF ACOUSTIC LOCALIZATION TO ONLINE POWER TRANSFORMERS APPLICATIONS OF ACOUSTIC LOCALIZATION TO ONLINE POWER TRANSFORMERS David Larochelle NDB Technologies Reasons leading to acoustic testing are different weather it is a manufacturing or field environment

More information

Application Note. Detection of Partial Discharge Using Ultrasound. Detection of Partial Discharge Using Ultrasound. Problem. iriss.

Application Note. Detection of Partial Discharge Using Ultrasound. Detection of Partial Discharge Using Ultrasound. Problem. iriss. Detection of Partial Discharge Using Ultrasound Problem In electrical systems, especially above 1,000 Volts, sufficient and properly maintained equipment insulation helps ensure equipment longevity. However,

More information

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets Abstract: For decades it has been recognized that partial discharge assessment is an excellent method

More information

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN 75 CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN 5.1 INTRODUCTION Partial Discharge (PD) detection is an important tool for monitoring insulation conditions in high voltage (HV) devices in power systems.

More information

Best Practice Reducing The Risk of Arc Flash Cross Over

Best Practice Reducing The Risk of Arc Flash Cross Over Best Practice Reducing The Risk of Arc Flash Cross Over 1 2 Electrical Systems Are Critical 3 Why Do We Complete Electrical Maintenance Energized?? 4 Which Bulb Is Not Working?? 5 Functioning Correctly

More information

PARTIAL DISCHARGE MEASUREMENT

PARTIAL DISCHARGE MEASUREMENT PARTIAL DISCHARGE MEASUREMENT Partial Discharges are small electrical sparks which occur predominantly at insulation imperfection. It is the phenomenon which occurs in the insulation on application of

More information

PD Diagnostic Applications and TechImp solutions

PD Diagnostic Applications and TechImp solutions PD Diagnostic Applications and TechImp solutions Condition Assessment Solutions for Electrical Systems. PD based innovative tools for the Condition Based Maintenance. MD-04.05.004 - rev. 00-29/08/2006

More information

Ultrasound Condition Monitoring

Ultrasound Condition Monitoring Ultrasound Condition Monitoring White Paper Author: Alan Bandes UE Systems, Inc 14 Hayes Street Elmsford, NY 10523 info@uesystems.com +914-592-1220 800-223-1325 1 2010 UE Systems, Inc all rights reserved

More information

What you discover today determines what you do tomorrow! Potential Use of High Frequency Demodulation to Detect Suction Roll Cracks While in Service

What you discover today determines what you do tomorrow! Potential Use of High Frequency Demodulation to Detect Suction Roll Cracks While in Service Potential Use of High Frequency Demodulation to Detect Suction Roll Cracks While in Service Thomas Brown P.E. Published in the February 2003 Issue of Pulp & Paper Ask paper machine maintenance departments

More information

Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks

Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks Proc. 2018 Electrostatics Joint Conference 1 Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks Satish Kumar Polisetty, Shesha Jayaram and Ayman El-Hag Department of

More information

Power Quality Monitoring and Analytics for Transmission and Distribution Systems

Power Quality Monitoring and Analytics for Transmission and Distribution Systems Power Quality Monitoring and Analytics for Transmission and Distribution Systems Doug Dorr Electric Power Research Institute Manager Advanced Monitoring Applications Group PQSynergy 2012 Evolving Smarter

More information

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates OMICRON Seminar on Substation Testing and Diagnosis October 23, 2017 Dubai, United Arab Emirates October 24, 2017 Abu Dhabi, United Arab Emirates Time Optimized Substation Asset Testing and Diagnosis Agenda

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

New Techniques for the Monitoring of Transformer Condition

New Techniques for the Monitoring of Transformer Condition New Techniques for the Monitoring of Transformer Condition Thomas Prevost OMICRON electronics USA IEEE T&D Conference Chicago, Illinois April 17, 2014 Agenda Monitoring Expectations & Needs Bushing Monitoring

More information

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015 Basics of Partial Discharge Prepared for 2015 Phenix RSM Meeting January 2015 Definitions and History Standard Definitions Fundamentally, what is a Partial Discharge An electric discharge which only partially

More information

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment International Research Journal of Engineering and Technology (IRJET) eissn: 23 0056 Volume: 04 Issue: 02 Feb 2017 www.irjet.net pissn: 072 A Review Comprehension: Guideline for Testing of HV, EHV and UHV

More information

MONTRANO. Continuous monitoring system for power transformers

MONTRANO. Continuous monitoring system for power transformers MONTRANO Continuous monitoring system for power transformers Condition monitoring to extend transformer life Knowing the dielectric condition of insulation is vital Dielectric flashover of insulation in

More information

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011 Use and Problems of On-line PD Measurement Technology on Switchgears in Guangzhou Distribution System XIONG Jun, WANG Yong, HUANG Huihong, HUANG Yanguang,LU Guojun,WU Bihua (Central Test and Researches

More information

ABB Power Products Service

ABB Power Products Service Raben Naidoo, Technology days, May 21-22th, 2014, Cape Town, South Africa, Enhanced availability of transformers via transformer remote monitoring - TEC ABB Power Products Service Why a session on availability?

More information

Advanced Monitoring Tools to Improve Distribution System Visibility and Reduce Faults and Outages

Advanced Monitoring Tools to Improve Distribution System Visibility and Reduce Faults and Outages Advanced Monitoring Tools to Improve Distribution System Visibility and Reduce Faults and Outages Presented to the 70th Annual Conference for Protective Relay Engineers Texas A&M University, College Station,

More information

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009 POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009 Nkosinathi Buthelezi Senior Consultant: Power Transformers and Reactors Presentation Content Standardization of Power

More information

Insulator Testers Frequently Asked Questions. September Version: 1.1

Insulator Testers Frequently Asked Questions. September Version: 1.1 Insulator Testers Frequently Asked Questions September 2017 Version: 1.1 1 FAQ Contents Page Q1: When is it not safe to work on power lines?... 3 Q2: What is the tolerance of the Positron Insulator Tester

More information

Partial Discharge, Survey or Monitor?

Partial Discharge, Survey or Monitor? July 2014 Partial Discharge, Survey or Monitor? 24-7 Partial Discharge monitoring is the ultimate tool for finding insulation weaknesses before they fail. Introduction It s well established that Partial

More information

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company SURGE ARRESTERS AND TESTING Keith Hill Doble Engineering Company Surge arresters are often overlooked when performing Power Factor tests on transformers, breakers and other apparatus in a substation. Often

More information

Transmission Availability Data System Definitions

Transmission Availability Data System Definitions Table of Contents Transmission Availability Data System Definitions February 1, 2018 1 of 31 3353 Peachtree Road NE Suite 600, North Tower Atlanta, GA 30326 404-446-2560 www.nerc.com Table of Contents

More information

T-68 Protecting Your Equipment through Power Quality Solutions

T-68 Protecting Your Equipment through Power Quality Solutions T-68 Protecting Your Equipment through Power Quality Solutions Dr. Bill Brumsickle Vice President, Engineering Nov. 7-8, 2012 Copyright 2012 Rockwell Automation, Inc. All rights reserved. 2 Agenda What

More information

Exclusive Technology Feature. Loop Control: Hand Calculations or Automation? Stabilizing CCM Flyback Converters. ISSUE: December 2009

Exclusive Technology Feature. Loop Control: Hand Calculations or Automation? Stabilizing CCM Flyback Converters. ISSUE: December 2009 ISSUE: December 2009 Loop Control: Hand Calculations or Automation? by Christophe Basso, ON Semiconductor, Toulouse, France Loop control is an important part in the design of a switching power supply,

More information

Electrical Equipment Reliability with Ultrasound & Infrared

Electrical Equipment Reliability with Ultrasound & Infrared Electrical Equipment Reliability with Ultrasound & Infrared Adrian Messer, Manager of US Operations UE Systems, Inc. Ph: 864-224-4517 Cell: 914-282-3504 Web: www.uesystems.com Email: adrianm@uesystems.com

More information

Evaluation of Distribution Line Spacers through the Leakage Current Monitoring

Evaluation of Distribution Line Spacers through the Leakage Current Monitoring Tsinghua University, Beijing, China, August -9, H-6 Evaluation of Distribution Line Spacers through the Leakage Current Monitoring A. G. Kanashiro *, W. Pinheiro and G. F. Burani Institute of Electrotechnics

More information

In order to minimise distribution (11 and 22 kv) feeder breaker

In order to minimise distribution (11 and 22 kv) feeder breaker Lightning protection for equipment on MV feeders By WJD van Schalkwyk and M du Preez, Eskom This article presents the influence of lightning on MV feeders supplying small power users (400/230 V) with focus

More information

Lightning Protection. Wisconsin Broadcasters Association Broadcasters Clinic. 14 th October 2009 Jeff Welton Regional Sales Manager, Central U.S.

Lightning Protection. Wisconsin Broadcasters Association Broadcasters Clinic. 14 th October 2009 Jeff Welton Regional Sales Manager, Central U.S. Lightning Protection Wisconsin Broadcasters Association Broadcasters Clinic 14 th October 2009 Jeff Welton Regional Sales Manager, Central U.S. Nautel Limited 2009 This presentation has been produced for

More information

Application of DFA Technology for Improved Reliability and Operations

Application of DFA Technology for Improved Reliability and Operations Application of DFA Technology for Improved Reliability and Operations IEEE/IAS Rural Electric Power Conference Columbus, Ohio, 24 April 2017 Robert A. Peterson, P.E., Director Control Center and Emergency

More information

Tab 8 Surge Arresters

Tab 8 Surge Arresters s en em Tab 8 Surge Arresters Si Distribution System Engineering Course Unit 10 2017 Industry Inc., All Rights Reserved Surge Arresters The main protective devices against system transient overvoltages.

More information

Great Northern Transmission Line: Behind the (Electrical) Design

Great Northern Transmission Line: Behind the (Electrical) Design Great Northern Transmission Line: Behind the (Electrical) Design November 8, 2017 Christian Winter, P.E. Minnesota Power Sivasis Panigrahi, P.E. POWER Engineers, Inc. What is the Great Northern Transmission

More information

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE Willem DIRKSE VAN SCHALKWYK ESKOM - South Africa vschalwj@eskom.co.za ABSTRACT A high BIL (300 kv) on a MV feeder ensures that no

More information

Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics

Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics Dominique Bolliger, Ph.D. HV TECHNOLOGIES, Inc. Manassas, VA, USA d.bolliger@hvtechnologies.com Abstract In

More information

Power Transformer Products & Services INCREASED PERFORMANCE & UPTIME

Power Transformer Products & Services INCREASED PERFORMANCE & UPTIME Power Transformer Products & Services INCREASED PERFORMANCE & UPTIME Grand Eagle Your Single Source for Transformer Support Others claim to provide total transformer services and support. Grand Eagle delivers

More information

process has few stages and is highly repeatable. Excellent mechanic properties and electro-magnetic compatibility. Planar design gives the height lowe

process has few stages and is highly repeatable. Excellent mechanic properties and electro-magnetic compatibility. Planar design gives the height lowe PARTIAL DISCHARGE IN PLANAR TRANSFORMER Ing. Anar MAMMADOV, Doctoral Degreee Programme (1) Dept. of Microelectronics, FEEC, BUT E-mail: xmamed00@stud.feec.vutbr.cz Supervised by Dr. Jaroslav Boušek ABSTRACT

More information

Ieee Guide For Partial Discharge Testing Of Shielded Power

Ieee Guide For Partial Discharge Testing Of Shielded Power Ieee Guide For Partial Discharge Testing Of Shielded Power We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer,

More information

Harmonic Components Analysis of Leakage Current for Standard and Anti-Fog Suspension Insulators under Humidity Conditions

Harmonic Components Analysis of Leakage Current for Standard and Anti-Fog Suspension Insulators under Humidity Conditions Harmonic Components Analysis of Leakage Current for Standard and Anti-Fog Suspension Insulators under Humidity Conditions R. Hajian M. Mirzaie Babol University of Technology, Iran Reza.hajian.7@gmail.com,

More information

DOW IMPROVES INSTRUMENT RELIABILITY 66% AND SAVES MILLIONS OF DOLLARS WITH REAL-TIME HART TECHNOLOGY

DOW IMPROVES INSTRUMENT RELIABILITY 66% AND SAVES MILLIONS OF DOLLARS WITH REAL-TIME HART TECHNOLOGY DOW IMPROVES INSTRUMENT RELIABILITY 66% AND SAVES MILLIONS OF DOLLARS WITH REAL-TIME HART TECHNOLOGY PROJECT OBJECTIVES Implement an Instrument Reliability Program as part of a larger equipment maintenance

More information

Development of a Prototype of a GSM based Underground Cable Fault Detector

Development of a Prototype of a GSM based Underground Cable Fault Detector Development of a Prototype of a GSM based Underground Cable Fault Detector Shreya Pal 1, Shubham Verma 2, Shashank Shakher Yadav 3, Dinesh Kumar 4, Amanpreet Kaur 5 1,2,3 Department of Electronics and

More information

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications Carlos Macià-Sanahuja and Horacio Lamela-Rivera Optoelectronics and Laser Technology group, Universidad

More information

Use of Advanced Monitoring Technology to Detect Incipient Failure of Line Equipment

Use of Advanced Monitoring Technology to Detect Incipient Failure of Line Equipment Use of Advanced Monitoring Technology to Detect Incipient Failure of Line Equipment 71st Annual Conference for Protective Relay Engineers Texas A&M University College Station, Texas USA 26-29 March 2018

More information

Partial discharge diagnostics on very long and branched cable circuits

Partial discharge diagnostics on very long and branched cable circuits 11 Nordic Insulation Symposium Stockholm, June 11-13, 2001 Partial discharge diagnostics on very long and branched cable circuits Nico van Schaik, E. Fred Steennis, Wim Boone and Dick M. van Aartrijk KEMA

More information

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE Z.Liu, B.T.Phung, T.R.Blackburn and R.E.James School of Electrical Engineering and Telecommuniications University of New South Wales

More information

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk.

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk. THE POWER OF LIFE WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk. Mr. Neal Yang Pro.E.E. Engineer About Us The flaw of dielectric material

More information

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES Thomas Steiner HIGHVOLT Prüftechnik Dresden GmbH Lifecycle of utilities time schedule utilities Tests during life cycle of utilities

More information

A New Use for Fault Indicators SEL Revolutionizes Distribution System Protection. Steve T. Watt, Shankar V. Achanta, and Peter Selejan

A New Use for Fault Indicators SEL Revolutionizes Distribution System Protection. Steve T. Watt, Shankar V. Achanta, and Peter Selejan A New Use for Fault Indicators SEL Revolutionizes Distribution System Protection Steve T. Watt, Shankar V. Achanta, and Peter Selejan 2017 by Schweitzer Engineering Laboratories, Inc. All rights reserved.

More information

ABSTRACTS of SESSION 6

ABSTRACTS of SESSION 6 ABSTRACTS of SESSION 6 Paper n 1 Lightning protection of overhead 35 kv lines by antenna-module long flashover arresters Abstract: A long-flashover arrester (LFA) of a new antenna-module type is suggested

More information

CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS

CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS CHAPTER 10 HIGH VOLTAGE TESTING OF ELECTRICAL APPARATUS 1. Introduction 2. Classification of High Voltage Tests 3. Test Voltages 4. High Voltage Testing of Electrical Apparatus 1. INTRODUCTION Purpose

More information

PCMS Engineering. Prediction. Prevention. Profit.

PCMS Engineering. Prediction. Prevention. Profit. PCMS Engineering Prediction. Prevention. Profit. www.pcmseng.co.uk Services Overview Whatever the scale of project, we can provide a solution and work with your organisation to integrate tools, techniques

More information

Welcome to the Session on. HT Distribution Network

Welcome to the Session on. HT Distribution Network Welcome to the Session on HT Distribution Network Learning Objective By the end of this session you will be able to: Explain the HT distribution network breakdown maintenance - possible faults, identification

More information

A STUDY ON THE RELATION BETWEEN LEAKAGE CURRENT AND SPECIFIC CREEPAGE DISTANCE

A STUDY ON THE RELATION BETWEEN LEAKAGE CURRENT AND SPECIFIC CREEPAGE DISTANCE A STUDY ON THE RELATION BETWEEN LEAKAGE CURRENT AND SPECIFIC CREEPAGE DISTANCE Mojtaba Rostaghi-Chalaki, A Shayegani-Akmal, H Mohseni To cite this version: Mojtaba Rostaghi-Chalaki, A Shayegani-Akmal,

More information

High-voltage electrical survey advancement

High-voltage electrical survey advancement High-voltage electrical survey advancement ABSTRACT Daniel A. Ninedorf Ox Creek Energy Associates, Inc. PO Box 600, Montello, WI 53949-0600 Tel: 800-531-6232 Fax: (608)589-5509 Email: cameras@maqs.net

More information

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS ENGINEERING DESIGN STANDARD EDS 08-2109 LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS Network(s): Summary: EPN, LPN, SPN This standard provides guidance on the installation of

More information

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors IRIS POWER TGA-B Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors We have not found another test method that produces as much decision support data for generator

More information

Analysis of Propagation Paths of Partial Discharge Acoustic Emission Signals

Analysis of Propagation Paths of Partial Discharge Acoustic Emission Signals Analysis of Propagation Paths of Partial Discharge Acoustic Emission Signals Prathamesh Dhole, Tanmoy Sinha, Sumeet Nayak, Prasanta Kundu, N.K.Kishore Abstract Transformers are one of the most important

More information

The Multi-Technology Approach to Motor Diagnostics

The Multi-Technology Approach to Motor Diagnostics The Multi-Technology Approach to Motor Diagnostics Howard W. Penrose, Ph.D. For: ALL-TEST Pro Old Saybrook, CT Introduction There has been a persistent misconception that there is a magic bullet, in the

More information

PARTIAL DISCHARGE DETECTION - AN OVERVIEW

PARTIAL DISCHARGE DETECTION - AN OVERVIEW PARTIAL DISCHARGE DETECTION - AN OVERVIEW 1 MR. N. J. PATEL, 2 PROF. K. K. DUDANI, 3 PROF. A. K. JOSHI 1 M.E. [Power System] P.G. Student, Department of Electrical Engineering, L. E. College of Engineering,

More information

In-Service Testing and Diagnosis of Gapless Metal Oxide Surge Arresters According to IEC

In-Service Testing and Diagnosis of Gapless Metal Oxide Surge Arresters According to IEC In-Service Testing and Diagnosis of Gapless Metal Oxide Surge Arresters According to IEC60099-5 Overview of presentation Motivation for condition monitoring of metal oxide surge arresters (MOSA) The Surge

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

Commercial Deployments of Line Current Differential Protection (LCDP) Using Broadband Power Line Carrier (B-PLC) Technology

Commercial Deployments of Line Current Differential Protection (LCDP) Using Broadband Power Line Carrier (B-PLC) Technology Commercial Deployments of Line Current Differential Protection (LCDP) Using Broadband Power Line Carrier (B-PLC) Technology Nachum Sadan - Amperion Inc. Abstract Line current differential protection (LCDP)

More information

Life Cycle Management of Station Equipment & Apparatus Interest Group (LCMSEA) Getting Started with an Asset Management Program (Continued)

Life Cycle Management of Station Equipment & Apparatus Interest Group (LCMSEA) Getting Started with an Asset Management Program (Continued) Life Cycle Management of Station Equipment & Apparatus Interest Group (LCMSEA) Getting Started with an Asset Management Program (Continued) Projects sorted and classified as: 1. Overarching AM Program

More information

Automated Power System Waveform Analytics for Improved Visibility, Situational Awareness, and Operational Efficiency

Automated Power System Waveform Analytics for Improved Visibility, Situational Awareness, and Operational Efficiency Automated Power System Waveform Analytics for Improved Visibility, Situational Awareness, and Operational Efficiency B. Don Russell (Presenter) Carl L. Benner Jeffrey Wischkaemper Karthick Muthu Manivannan

More information

DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS

DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS Jung-Taek Kim, Hyeonmin Kim, Wan Man Park Korea Atomic Energy Research Institute 145 Daedeok-daero, Yuseong-gu,

More information

Leslie J. Anderson Supervising Attorney Public Service Commission of West Virginia 201 Brooks St. PO Box 812 Charleston, WV Dear Ms.

Leslie J. Anderson Supervising Attorney Public Service Commission of West Virginia 201 Brooks St. PO Box 812 Charleston, WV Dear Ms. J 5001 NASA Boulevard Fairmonl, WV 26554 Gary A. Jack Senior Cornorale Counsel VIA EMAIL AND FEDEX OVERNIGHT Leslie J. Anderson Supervising Attorney Public Service Commission of West Virginia 201 Brooks

More information

Practical Experience in On-Line Partial Discharge Measurements of MV Switchgear Systems

Practical Experience in On-Line Partial Discharge Measurements of MV Switchgear Systems Practical Experience in On-Line Partial Discharge Measurements of MV Switchgear Systems Z. Berler, I. Blokhintsev, A. Golubev, G. Paoletti, V. Rashkes, A. Romashkov Cutler-Hammer Predictive Diagnostics

More information

Presented By: Michael Miller RE Mason

Presented By: Michael Miller RE Mason Presented By: Michael Miller RE Mason Operational Challenges of Today Our target is zero unplanned downtime Maximize Equipment Availability & Reliability Plan ALL Maintenance HOW? We are trying to be competitive

More information

Xu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP)

Xu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP) Xu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP) April 12, 2010 Slide 1 Content MV Machine Winding Insulation Stress LEAP Methodology LEAP Standard LEAP from

More information

Understanding Ultrasonic Signal Analysis By Thomas J. Murphy C.Eng.

Understanding Ultrasonic Signal Analysis By Thomas J. Murphy C.Eng. Understanding Ultrasonic Signal Analysis By Thomas J. Murphy C.Eng. INTRODUCTION This paper reviews the application of digital portable ultrasound technology as a diagnostic tool in predictive maintenance.

More information

Online Assessment of Capacitor Banks Using Circuit Health Monitoring Technology

Online Assessment of Capacitor Banks Using Circuit Health Monitoring Technology Online Assessment of Capacitor Banks Using Circuit Health Monitoring Technology Jeffrey Wischkaemper (Presenter) B. Don Russell Carl L. Benner Karthick Muthu Manivannan Texas A&M University College Station,

More information

Predictive Subsea Integrity Management: Effective Tools and Techniques

Predictive Subsea Integrity Management: Effective Tools and Techniques Predictive Subsea Integrity Management: Effective Tools and Techniques The Leading Edge of Value-Based Subsea Inspection 1 st November Aberdeen 2017 www.astrimar.com Background Low oil price having major

More information

Effect of Shielded Distribution Cable on Very Fast Transients

Effect of Shielded Distribution Cable on Very Fast Transients IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 15, NO. 3, JULY 2000 857 Effect of Shielded Distribution Cable on Very Fast Transients Li-Ming Zhou and Steven Boggs, Fellow, IEEE Abstract Fast transients in

More information

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer Scientific Journal of Impact Factor(SJIF): 3.134 International Journal of Advance Engineering and Research Development Volume 2,Issue 7, July -2015 e-issn(o): 2348-4470 p-issn(p): 2348-6406 Comparison

More information

How to Use the Method of Multivariate Statistical Analysis Into the Equipment State Monitoring. Chunhua Yang

How to Use the Method of Multivariate Statistical Analysis Into the Equipment State Monitoring. Chunhua Yang 4th International Conference on Mechatronics, Materials, Chemistry and Computer Engineering (ICMMCCE 205) How to Use the Method of Multivariate Statistical Analysis Into the Equipment State Monitoring

More information

The Decision Aid Leak Notification System for Pigging False Alarm

The Decision Aid Leak Notification System for Pigging False Alarm ISBN 978-93-84468-94-1 International Conference on Education, Business and Management (ICEBM-2017) Bali (Indonesia) Jan. 8-9, 2017 The Decision Aid Leak Notification System for Pigging False Alarm Thanet

More information

Introduction. Corona. Corona Cameras. Origo Proposed Corona Camera. Origo Corporation Corona Camera Product Inquiry 1

Introduction. Corona. Corona Cameras. Origo Proposed Corona Camera. Origo Corporation Corona Camera Product Inquiry 1 Origo Corporation Corona Camera Product Inquiry 1 Introduction This Whitepaper describes Origo s patented corona camera R&D project. Currently, lab and daylight proof-of-concept tests have been conducted

More information

Acoustic Emission in power transformers. Ajusco 15, Colonia Portales, Delegación Benito Juárez, C.P , México, D.F.

Acoustic Emission in power transformers. Ajusco 15, Colonia Portales, Delegación Benito Juárez, C.P , México, D.F. Acoustic Emission in power transformers 1 More expensive equipment in the substation Many years of operation First indication of a problem: Dissolved Gases Begin investigation to determine the origin of

More information

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE INCH-POUND MIL-STD-202-301 18 April 2015 SUPERSEDING MIL-STD-202G w/change 2 (IN PART) 28 June 2013 (see 6.1) DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE AMSC

More information

QUESTIONNAIRE ON FAULT LOCATION SYSTEMS

QUESTIONNAIRE ON FAULT LOCATION SYSTEMS For WG B5.52 Analysis and comparison of fault location systems in substation automation systems The objective of this questionnaire is to obtain information of nowadays fault location systems used by the

More information

Photonic Power. Application Overview

Photonic Power. Application Overview Photonic Power Application Overview Photonic Power Harnessing the Power of Light Photonic power is a novel power delivery system whereby light from a laser source illuminates a photovoltaic power converter

More information

ArresterFacts 024. Separation Distance for Substations. ArresterFacts 024 Separation Distance for Substations. September 2014 Rev 7 Jonathan Woodworth

ArresterFacts 024. Separation Distance for Substations. ArresterFacts 024 Separation Distance for Substations. September 2014 Rev 7 Jonathan Woodworth ArresterWorks ArresterFacts 024 Separation Distance for Substations Separation Distance for Substations September 2014 Rev 7 Jonathan Woodworth ArresterFacts 024 Copyright ArresterWorks 2014 Page 1 for

More information

Specialists in HV and MV test and diagnostics. Testing in Substations

Specialists in HV and MV test and diagnostics. Testing in Substations Specialists in HV and MV test and diagnostics Testing in Substations Testing in Substations Testing in Substations At 4fores we specialize in the diagnosis and measurement of all types of existing technologies

More information

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS n Quality made in Germany n Standardized and customized solutions n Turn key projects, all from one hand 0.1-1/1 Product Portfolio Test and Measuring Systems

More information

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C S O L U T I O N S Y O U R S O U R C E F O R T O P Q U A L I T Y T E S T E Q U I P M E N T w w w. h v t e c h n o l o g i e s. c o m Company

More information

Lessons Learned in Conducting Acoustic Leak Detection Surveys on Water Distribution Systems at 12 Military Installations

Lessons Learned in Conducting Acoustic Leak Detection Surveys on Water Distribution Systems at 12 Military Installations Lessons Learned in Conducting Acoustic Leak Detection Surveys on Water Distribution Systems at 12 Military Installations Harmon Henderson, PE Perry Gayle, PhD, PE, LEED AP 14 April 2015 Presentation Overview

More information