1 MANN SERIES Process alarms PA Series Two-channel modules for alarm monitoring Typical application of PAMA Modules in the PA Series are used for alarm monitoring. They can be configured for a wide variety of industrial signals and feature two alarm outputs. Setpoint values and deadband can be individually adjusted by using a potentiometer. The deadband reduces chatter from the monitoring relay during switching operations. The reset point of the alarm contact is individually adjusted in this case away from the hysteresis (setpoint). In order to generate an alarm in the event of a power outage, the user should select the energized operational status for one or both of the output relays. A high/low-trip switching behaviour can also be set independently for each channel. Power supply V C Relay supply z. B. 30 V AC Alarm Relay channel PA / MA /...0 ma V C... 0 ma Relay channel 1 evel transmitter Valve The following analogue input signals can be processed by the PA Series: temperature (thermocouple and PT100 temperature detector), AC/C currents/voltages, frequencies, measuring potentiometers, differential currents and differential resistances. The housing can be snapped onto a IN TS 35 or TS 3 mounting rail. The pluggable screw connection is located on the front. Technical features: A wide variety of versions available for many types of input signals Two independent alarm channels with relay output E status display Min./max switching coands in any combination igh repetition accuracy eadband/setpoint adjustment on front panel Complete electrical isolation to kv C power supply Pluggable screw-connection mechanism Compact metal housing 1 epending on the 3 individual module 5 6 Not used Supply voltage 10 + contacts Alarm channel 1 1 (Relay contacts) contact contacts Alarm channel (Relay contacts) contact ousing PE connection direct on housing

2 PA Series PAMA Current monitoring 0 ma Analogue signal conditioning For current signals [ma C] ow input impedance Bi-polar input signals on request Supply of active input devices 1 + V Iin 0 V 0V + V I 1 ent input [ma] signal 10 Ω (additional on request) resistance range min./max. ma Offset 0 % of signal range Switching current V C / 0 V AC ead time vom max. Eingangswert Options fset: zero point > signalling range ong-term drift h Current input [ma] Ω (additional on request) 10 Ω e 0 μa 500 ma % of signal range 3 0 V AC, 3 V C / 0 V AC V C ± 10 % igh Offset: zero point > signalling range 3 V C tion IN EN 66 s CE; cuusrprovals 1 V C Signal + Signal ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Current input PAMA -0mA PA Variabel

3 PA Series PAMV Voltage monitoring 0 10(100) mv For voltage signals [mv C] igh input impedance Bi-polar input signals on request + Vin 0 V 0 V + V V 1 ages ( 100 mv) signal V or mv resistance range min./max. Offset h;500 % of signal range Switching current V C / 0 V AC ead time vom max. Eingangswert Options fset: zero point > signalling range ong-term drift h Voltages ( 100 mv) 0 10 mv or mv 10 MΩ tance mv C ax % of signal range 3 0 V AC, 3 V C / 0 V AC V C ± 10 % igh Offset: zero point > signalling range 3 V C tion IN EN 66 s CE; cuusr provals Signal + Signal ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Voltage input Voltage input PAMV 0-100mV PAMV 0-10mV PA Variabel

4 PA Series PACV Voltage monitoring 0 10 V / 1 5 V Analogue signal conditioning For voltage signals [V C] igh input impedance Bi-polar inputs on request Vin 0 V 0V + V V 1 oltage [> 500 mv] signal or 1 5 V (additional on request) resistance 10 V) or 500 kω (1 5 V) range min./max. Offset 0 % of signal range Switching current V C / 0 V AC ead time vom max. Eingangswert Options fset: zero point > signal range igh voltage: for ranges > 60 V ong-term drift h C voltage [> 500 mv] 0 10 V or 1 5 V (additional on request) 1 MΩ (0 10 V) or 500 kω (1 5 V) V C ax % of signal range 3 0 V AC, 3 V C / 0 V AC V C ± 10 % igh offset: zero point > signal range igh voltage: for ranges > 60 V 3 V C tion IN EN 66 s CE; cuusr provals Signal + Signal ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Voltage input Voltage input PACV 0-10V PACV 1-5V PA Variabel

5 PA Series PAAVX Voltage monitoring 0 50 V AC For voltage signals [V AC] igh input impedance 0 V + V Accuracy Class 0.5 Vin Vin Uac nung [AC] frequency range resistance signal (additional on request) range min./max. Offset 0 % of signal range Switching current V C / 0 V AC ead time vom max. Eingangswert Options fset: offset > signalling range igh Voltage: input voltage > 60 V AC Tolerance class Voltages [AC] 7 63 z range > 1 MΩ ance 0 50 V AC (additional on request) 8 mv 50 V AC % of signal range typ. 0 ms sponse time 3 0 V AC, 3 V C / 0 V AC V C ± 10 % igh Offset: offset > signalling range igh Voltage: input voltage > 60 V AC 3 V C tion 0.5 erance class IN EN 66 s CE; cuus AC Voltage AC Voltage ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Voltage input PAAVX 0-15Vac PA Variabel

6 PA Series PART Temperature monitoring (RT) Analogue signal conditioning For temperature signals [ C] - or 3-wire connection 0 V + V Automatic cable-length compensation A 3 B BSENSE J 1 0 -/3-wire Interference characteristic Sensor current Switching current V C / 0 V AC ead time vom max. Eingangswert Cable-length compensation reduces the influence of conductor resistance by a factor of 100. ong-term drift h PT100 -/3-wire igh Alarm ce characteristic 0.5 ma current 3 0 V AC, 3 V C / 0 V AC Cable-length compensation reduces the influence of conductor resistance by a factor of 100. V C ± 10 % 3 V C tion IN EN 66 s CE; cuus A 3 B B-Sense ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Temperature converter Temperature converter Temperature converter PART 0-100C PART 0-00C PART 0-50C

7 PA Series PATCX Temperature monitoring (thermal converter) For all standard thermocouples Automatic cold-junction compensation 0 V + V Wire-break recognition can be set + 3 _ J 1 moelement signal 1000 C ) (additional on request) resistance Interference characteristic Switching current V C / 0 V AC ead time vom max. Eingangswert Cold-junction compensation Options eak recognition: igh Alarm / ow Alarm ong-term drift h Thermocouple K ( C ) (additional on request) 10 MΩ tance igh oder ow Alarm teristic 3 0 V AC, 3 V C / 0 V AC Automaticallyon compensation Wire-break recognition: igh Alarm / ow Alarm V C ± 10 % 3 V C tion IN EN 66 s CE; cuusr provals Signal + Signal ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Temperature converter PATCX K/0-1000C PA Variabel

8 PA Series PAPOT Position monitoring Analogue signal conditioning Position detection Potentiometer and loop input 0 V + V 3 B (100%) A (0%) J 1 nductor partial-voltage meter or measuring conductor signal.1 MΩ (percent of potentiometer range) Switching current V C / 0 V AC ead time vom max. Eingangswert ong-term drift h 3-conductor partial-voltage meter or measuring conductor 10 Ω 1 MΩ (percent of potentiometer range) 3 0 V AC, 3 V C / 0 V AC V C ± 10 % 3 V C tion IN EN 66 s CE; cuusrprovals Wiper 3 B A ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Resistor input Resistor input PAPOT 10KM/0-100% PAPOT 1KM/0-100% PA Variabel

9 PA Series PARES Resistance monitoring -wire input 0 V + V A B J 1 re resistance signal a; (0 Ω 100 kω on request) Switching current V C / 0 V AC ead time vom max. Eingangswert ong-term drift h -wire resistance 0 1 kω (0 Ω 100 kω on request) 3 0 V AC, 3 V C / 0 V AC V C ± 10 % 3 V C tion IN EN 66 s CE; cuusrprovals A B ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Resistor input PARES 0-1KM PA Variabel

10 PA Series PAMAS Monitoring of residual current Analogue signal conditioning Residual current measuring Monitoring of two current signals 0 V + V Iin (A) Iin (B) 0 V I 1 rrent inputs [ma] signal A (additional upon request) resistance Switching current V C / 0 V AC ead time vom max. Eingangswert Transmit function ong-term drift h current inputs [ma] 0 ma (additional upon request) 10 Ω stance 3 0 V AC, 3 V C / 0 V AC output x A-B ction V C ± 10 % 3 V C tion IN EN 66 s CE; cuusr provals Signal A+ 3 Signal B+ Signal ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Current input PAMAS -0mA PA Variabel

11 PA Series PART Resistance monitoring Residual current measuring Monitoring of two resistance values 3 0 V + V J 1 Widerstände R1 und R in -raht Konfiguration mit R1 > R signal range min./max. 100 kω Reference resistance ffset Switching current V C / 0 V AC ead time vom max. Eingangswert Transmit function Options fset: offset > signalling range ong-term drift h Two resistance R1 and R in -wire configuration with R1 > R signal (R1-R) 0 Ω 100 kω % of input offset 3 0 V AC, 3 V C / 0 V AC output x R1-R ion igh Offset: offset > signalling range V C ± 10 % 3 V C tion IN EN 66 s CE; cuusr provals R 1 3 R ata of ousing Clamping range (rating- / min. / max.) of ousing / Weight ength x width x height Resistor input PART 00M0-0M PA Variabel

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

Indicators and configurable displays

Indicators and configurable displays Contents Overview.2 Process value displays with LED display.4 Process value displays with LCD display.20 1460730000 2014/2015.1 Overview In industrial and process automation, displays provide a visual

More information

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph:

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph: X A L I S XALIS is a new digital indicator range with 2 colors numerical and alphanumerical display designed to provide display and signals transmission solutions. XALIS disign allows exceptional performances

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

DOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance.

DOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance. DOCUMENTATION The new integrates a 32 bits microprocessor offering some more of performance. XALIS is a new digital indicator range with 2 colors numerical and alphanumerical display designed to provide

More information

Ouput Loop Powered Products Section C

Ouput Loop Powered Products Section C Ouput Loop Powered Products Section C An output loop powered (or signal powered) isolator derives its power from the voltage drop across the device's current loop output. Because they require no separate

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

WAVESERIES Signal converters

WAVESERIES Signal converters WAVESERIES Overview WAVESERIES Signal converters Isolation and conversion of analogue signals enclosed in a rail-mounted WAVEBOX housing WAVESERIES products are well suited for users seeking an analogue

More information

Economical Digital Indicators For Process and Electrical Measurement

Economical Digital Indicators For Process and Electrical Measurement Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

TxBlock-USB Transmitter

TxBlock-USB Transmitter Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is

More information

T E L I S T E L I S reinvents conversion and transmission of measures

T E L I S T E L I S reinvents conversion and transmission of measures T E L I S 9000 T E L I S reinvents conversion and transmission of measures Its graphic screen display, and its joystick make user-frendly and easily programmable device. Its USB front face plug enables

More information

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM104 SERIES SEM104P Pt100 Temperature Transmitter SEM104TC Thermocouple Temperature Transmitter SEM104P 1 1.0 DESCRIPTION 2 2.0 SPECIFICATION 2 3.0 INSTALLATION 24 4.0

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

DOCUMENTATION. Its affordable price allows you to meet your budget target.

DOCUMENTATION. Its affordable price allows you to meet your budget target. DOCUMENTATION ULCOS is a real concentrate of technology, mixing performance and versatility. It is able to meet your high level expectation, for technical tender specifications. Its affordable price allows

More information

AKP-AKU DIGITAL PANEL METER

AKP-AKU DIGITAL PANEL METER DIGITAL PANEL METER AKP-AKU Isolated digital indicators AKP and AKU are designed to provide display and signals transmission solutions. Its unique programmation principle on front plate or by digital output

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

Installation- / Monitoring technique

Installation- / Monitoring technique Installation- / Monitoring technique ifferential current monitor IP 5883, Type B for AC and C systems varimeter 0249633 IP 5883 N 5018/035 N 5018/030 According to IEC/EN 62 020, VE 0663 To detect earth

More information

Datasheet ACT20M Signal Isolation and Conversion NEW

Datasheet ACT20M Signal Isolation and Conversion NEW Datasheet ACT0M Signal solation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Features include worldwide

More information

Industrial Interface The Signal Conditioning People

Industrial Interface The Signal Conditioning People Loop Powered Products including: 420TW 420i RTD/TC-HEAD Isolating Terminal Blocks Loop Powered Isolators In-Head Transmitters DC/AC Powered Isolation including: ISOCON DUALCON SLIMCON TC-TC VCON STRAIN

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

Temperature Controller

Temperature Controller Temperature Controller 1/8 IN - 48 x 96mm Platinum Series X400 Line Cost Effective Solutions This 48x96mm size controller of the Platinum Series, provides a high degree of functionality and reliability

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits for s or voltages, temperature sensors, remote sensors or potentiometers pplication The universal transmitter RISH Ducer V 604 (Figures 1 and 2) convert the input variable a or voltage, or a signal from

More information

SINEAX V604s Programmable multifunctional transmitter

SINEAX V604s Programmable multifunctional transmitter SINAX V60s for direct currents, direct voltages, temperature sensors, teletransmitters or potentiometers SINAX V60s is a multifunctional transmitter for tophat rail assembly with the following main characteristics:

More information

2002-ALM USER MANUAL

2002-ALM USER MANUAL 00 - ALM DUAL TRIP AMPLIFIER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting from errors or omissions,

More information

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

MCR-T-UI(/NC) MCR-T-UI-E(/NC) MCR-T-UI(/) MCR-T-UI-E(/) Programmable Temperature Transducers for Resistance Thermometers and Thermocouples INTERFACE ata Sheet 00_0_en PHOENIX CONTACT - 0/00 escription A universal temperature measuring

More information

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Multifunction Intelligent 4-wire Isolated Signal Conditioner Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.

More information

Technical Information Barrier RB223

Technical Information Barrier RB223 TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits

More information

Digital Indicator DS 96/48 PK

Digital Indicator DS 96/48 PK Data Sheet 10/33-2.1-EN Digital Indicator DS 9/48 P Digital Indicator DS 9/48 PK Inputs Direct current, direct voltage Thermocouple Resistance thermometer Programmable via front keys or PC software Limit

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

installation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting

installation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting Digital panel meter 5-digit M3 red display from -19999 99999 Digits (optional green, orange or blue display) installation depth: 90 mm without plug-in terminal min-/max-memory 30 additional adjustable

More information

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided

More information

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu PM8005/6 AC and DC supply options 5 digit LED display Direct access menu Functions for calibration, alarm setting and more Wide range of optional functions Description The PM8000 Series digital panel meters

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

RTD/RES. Pot. Output type Min Max Min. span. Current 4 ma 20 ma 4 ma. Burn-out values Max. output value 21.8 ma Min. output value 2.

RTD/RES. Pot. Output type Min Max Min. span. Current 4 ma 20 ma 4 ma. Burn-out values Max. output value 21.8 ma Min. output value 2. DN Rail Signal Transmitter Phone: 9 - e-mail:datexel@datexel.com- www.datexel.com Universal isolated transmitter configurable by Dip-Switch or PC DAT FEATURES - Universal configurable input for: mv, Tc,

More information

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16 MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......

More information

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners DRLP Series U ±0.03% Accuracy (Typical) U ±0.01% Linearity U 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection U Wide Loop

More information

Bulletin 931 Signal Conditioners Technical Data

Bulletin 931 Signal Conditioners Technical Data Technical Data Table of Contents/Product Line Overview Introduction to..................................4 Catalog Number Explanation.......................................6 Product Overview................................................7

More information

SINEAX V 604s Programmable multifunctional transmitter

SINEAX V 604s Programmable multifunctional transmitter SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:

More information

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module Product overview The AX-ROM135 and the AX-ROM1000 Modules enable an Analogue, Pulse or Floating point signal and convert to either a 0-135Ω or a 1KΩ Proportional Resistive output signal. The output resistance

More information

Description of functions Controller system VR660 / A200R

Description of functions Controller system VR660 / A200R Description of functions Controller system VR660 / A00R Local bus RS VR660/A00R e 56 76-0.07 Camille Bauer AG Aargauerstrasse 7 CH-560 Wohlen/Switzerland Phone + 56 68 Fax + 56 68 5 5 e-mail: info@camillebauer.com

More information

SINEAX V 604 Programmable universal transmitter

SINEAX V 604 Programmable universal transmitter for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The universal transmitter SINEAX V 604 (Figures 1 and 2) converts the input variable a DC current

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

installation depth: 90 mm without plug-in terminal 30 additional adjustable setpoints permanent MIN/MAX-value recording volume measuring (totaliser)

installation depth: 90 mm without plug-in terminal 30 additional adjustable setpoints permanent MIN/MAX-value recording volume measuring (totaliser) Digital panel meter 5-digit M3 red display from -19999 99999 Digits (optional green, orange or blue display) installation depth: 90 mm without plug-in terminal adjustment via factory default or directly

More information

DPS Series 5W, 10W, 18W AC/DC DIN Rail Power Supplies

DPS Series 5W, 10W, 18W AC/DC DIN Rail Power Supplies DPS Series 5W, 1W, 18W AC/DC DI Rail Power Supplies AC - DC din rail mountable 5W, 1W and 18W class 2 power supplies E A R G U A R A T E E z U, cu, CE z Universal input 9~265VAC z High efficiency up to

More information

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display. Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long

More information

USB-2404-UI Specifications

USB-2404-UI Specifications Specifications Document Revision 1.1, April, 2011 Copyright 2011, Measurement Computing Corporation All specifications are subject to change without notice. Typical for the range 0 to 60 C unless otherwise

More information

2002 IS Catalog. Page

2002 IS Catalog. Page Page Introduction... 95 Current Repeaters/Drivers (Single-channel) KFD0-CS-Ex1.50P (Transmitter, positioner and indicator)... 96 KFD0-CS-Ex1.51P (Positioner and fire detector)... 97 KFD0-CS-Ex1.52 (Current

More information

S200 I/O System Units

S200 I/O System Units S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

Modicon Momentum automation platform 0

Modicon Momentum automation platform 0 Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V,

More information

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions: KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications:

More information

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 57 mm without plug-in terminal adjustment via factory default or directly

More information

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J Electrical temperature measurement Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J WIKA data sheet TE 91.01 for further approvals

More information

Adjustable Digital Process Instrument MDK480

Adjustable Digital Process Instrument MDK480 Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485) Module type High-speed Digital ler SRX SRX General Description The SRX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control

More information

General Specifications

General Specifications General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O

More information

Take the current. Clamp meters available for diverse applications and conductor diameters.

Take the current. Clamp meters available for diverse applications and conductor diameters. Take the current to the meter. for DC and AC. Our clamp meters are set apart by their versatile functions. The displays allow measured values to be read quickly, even under diffi cult conditions. Most

More information

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters

More information

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage. ProLine Interface Technology Loop-Powered Isolators for Standard Signals For isolation of 0(4)... 20 ma standard current signals on up to 3 channels. The Task If no power supply is available, the galvanic

More information

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

Thermocouple Conditioner and Setpoint Controller AD596*/AD597* a FEATURES Low Cost Operates with Type J (AD596) or Type K (AD597) Thermocouples Built-In Ice Point Compensation Temperature Proportional Operation 10 mv/ C Temperature Setpoint Operation ON/OFF Programmable

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 25 mm without plug-in terminal adjustment via factory default or directly

More information

Sample Test Data SWF Series SWF100P W, High Surge Tolerant, Low Noise Power Supply

Sample Test Data SWF Series SWF100P W, High Surge Tolerant, Low Noise Power Supply Sample Test Data SWF Series SWF100P-24 100 W, High Surge Tolerant, Low Noise Power Supply General Description The SWF series are compact, wide ranging power supplies, providing peak power capability that

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN Electronic alarm signalling unit TES 20 ENA117.01 EN for temperature and standard signals Universal alarm signalling unit (constructional width 4 T) for Temperature (temperature monitor) with Pt 100 IEC

More information

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple, AD597 SPECIFICATIONS (@ +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple, unless otherwise noted) Model AD596AH AD597AH AD597AR Min Typ Max Min Typ Max Min Typ Max Units ABSOLUTE MAXIMUM

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

Modular Smart Interfaces

Modular Smart Interfaces Modular Smart Interfaces Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Modular Smart Interfaces MSI Series Modular Smart Interfaces (MSI) bring an expanded

More information

SPECIFICATION Item no.: T60404-N4646-X201

SPECIFICATION Item no.: T60404-N4646-X201 SPECFCATON tem no.: T60404-N4646-X201 For the electronic measurement of currents: isolation between the primary circuit (high power) and the secondary circuit (electronic circuit) Customer: Standard type

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

DRG-SC Series Signal Conditioners

DRG-SC Series Signal Conditioners DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable

More information

SPECIFICATION Item no.: T60404-N4646-X300

SPECIFICATION Item no.: T60404-N4646-X300 SPECFCATON tem no: T60404-N4646-X300 K-No: 24577 Date: 16042014 For the electronic measurement of currents: solation between the primary circuit (high power and the secondary circuit (electronic circuit

More information

Trip amplifier, 1 channel

Trip amplifier, 1 channel Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5

More information

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional valves with electrical position feedback Valve amplifier for proportional valves with electrical position feedback Type VT-MRPA1-... RE 30221 Edition: 2015-02 Replaces: 2013-08 Component series 1X Analog, modular design Intended for controlling

More information

658 Current to Position Converters

658 Current to Position Converters 658 Current to Position Converters Current to Position Converters for Solid State Switching Output Adjustable Zero, Span and Deadband Two Wire Input from Controller Operates with 90 to 1000 Ω Feedback

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 72 Manchester Road Kearsley Bolton BL4 8NZ Contact: Mr A Leonard Tel: +44 (0) 1204 571499 Fax: +44 (0) 1204 571734 E-Mail: enquiries@airflowmeasurements.com Website: www.airflowmeasurements.com AIR VELOCITY

More information

CALYS 50. Field multifunction calibrator for basic use

CALYS 50. Field multifunction calibrator for basic use Field multifunction calibrator for basic use CALYS 50 field multifunction calibrator is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable 1. Short description configurable inputs and outputs signal conversion/amplification 3-way-isolation zero/span adjustment 17.5 mm ME housing

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven) Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice Issued: April 1999 Status: Updated Version: B/08.11.200 Data subject to change without notice Features Versatile, multifunction line fault indicator for distribution networks Overcurrent, earth-fault and

More information