Installation. Symmetra MW II kw 480 V

Size: px
Start display at page:

Download "Installation. Symmetra MW II kw 480 V"

Transcription

1 ~ ~ Installation Symmetra MW II 000 kw 480 V

2

3 Contents Safety... IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Symbols used in this guide Installation safety System Overview...3 UPS Sections Serial number Inverter Section Control Section Input/Output Section Configurations Configuration (Inverter Section placed to the left) Configuration (Inverter Section placed to the right) External Bypass Static Switch Serial number Electrical Installation...7 Typical UPS Wiring Principle Power wiring overview External disconnection switches Input/Output wiring precautions Top Cable Entry Preparing for top cable entry (default) Battery cable connections (top cable entry) Ground and AC cable connections (top cable entry) i

4 Bottom Cable Entry Preparing for bottom cable entry Battery cable connections (bottom cable entry) Ground and AC cable connections (bottom cable entry) Bypass Static Switch Wiring Top cable entry Bottom cable entry Communication Cable Overview Relay Boards Location of relay boards Relay board communication cables Relay board connections Relay board connections Specifications... 5 LowImpedance/HighImpedance Grounding Lowimpedance grounding Highimpedance grounding Electrical Specification Installation Planning Data AC Input DC Input AC Output AC Input External Bypass SSW Heat Dissipation Notes Table Table 306 (National Electrical Code) Recommended cable, bolt, and lug sizes Torque specifications Required Breaker Settings Input and upstream breakers Output and downstream breakers General Specifications 480 V ii

5 Safety IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This guide contains important instructions for SYMF000KG that should be followed when handling the UPS, External Bypass Static Switch, Battery Enclosures, and Batteries. Symbols used in this guide Warning: Indicates an electrical hazard, which, if not avoided, could result in injury or death. Caution: Indicates a hazard, which, if not avoided, could result in injury or death. Note: Indicates important information. Indicates that more information is available on the subject. Main Protective Earthing Terminal symbol. Ground symbol. Installation safety EPO Press the EPO (Emergency Power Off) button to switch off all AC and DC power supply to connected equipment in the room. The EPO is typically located on a wall in the room in which the UPS is installed. See Communication cable overview section for information on how to wire the UPS to the EPO. Warning: Before you start the installation, verify that all AC and DC power source breakers are in the open position. Warning: Only personnel trained in the construction and operation of the equipment, and the electrical and mechanical hazards involved, must install or remove system components.

6 Warning: Do not use high voltage testing equipment as it will destroy the electronic circuits in the units. Caution: The system is equipped with an optional autostart function enabling the system to start without any warning when power is applied. Caution: All wiring must be in accordance with applicable national and/or local electrical codes. This unit contains components that are sensitive to electrostatic discharge (ESD). Follow proper ESD procedures to avoid severe damage to electronic components. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Installation Manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

7 System Overview UPS Sections The UPS system consists of an 000 kw Inverter Section, a Control Section, an Input/Output Section and an External Bypass Static Switch Section. Serial number The serial number is stated on the type label behind the finishing panel above the display unit. Remove finishing panel to see serial number. Inverter Section The Inverter Section regulates the UPS output and operates from battery power in the event of utility input loss. Control Section The Control Section controls and monitors the UPS and the Main Static Switch (incorporated in the Control Section). Input/Output Section The Input/Output Section provides electrical connection of input and output. 3

8 ~ ~ Configurations The UPS system can be configured in two ways. The Inverter Section can be placed either to the left or to the right of the Control Section. The two configurations are shown below. Configuration (Inverter Section placed to the left) 03 mm (80 in) 067 mm (4 in) Inverter Section Width: mm (83.5 in) Control Section Width: 0 mm (39.84 in) Total width of UPS sections: 438 mm (63 in) Weight: Without Power Modules: 497 kg (933 lb) With Power Modules: 5049 kg (08 lb) Input/Output Section Width: 04 mm (39.9 in) 4

9 Configuration (Inverter Section placed to the right) 03 mm (80 in) 067 mm (4 in) Input/Output Section Width: 04 mm (39.9 in) Control Section Width: 0 mm (39.84 in) Inverter Section Width: mm (83.5 in) Total width of UPS sections: 438 mm (63 in) Weight: Without Power Modules: 497 kg (933 lb) With Power Modules: 5049 kg (08 lb) 5

10 ~ ~ Normal External Bypass Static Switch The External Bypass Static Switch (External Bypass SSW) transfers the load (manually or automatically) from the UPS to an alternate source without interrupting the power to the load. 03 mm (80 in) 067 mm (4 in) Serial number External Bypass Static Switch Width: 04 mm (39.8 in) Weight: 460 kg (0 lb) The serial number is stated on the type label behind the finishing panel above the display unit. Remove finishing panel to see serial number. 6

11 Electrical Installation Typical UPS Wiring Principle Power wiring overview See separate manual on parallel operation for wiring overview in parallel systems. AC Mains Input Lugs 480 V, 3PH, 3W & GND Q Q5 Battery Battery Breakers Q7 Battery Q8 5 UPS 7 SSW 7 External Battery Q Q6 KK 4 Q4 Q3 KK 4 4 LBB KK V, 3PH, 3W & GND Output Load Lugs SOURCE AND AC CABLING MUST BE 480 VOLT, WYE CONNECTED, 3 PHASE, 3 WIRE + GROUND (CONTACT APC IF OTHER). DASHED LINES BETWEEN UNITS ( ) REPRESENT AC/DC CABLING PROVIDED BY OTHERS. ALL AC CIRCUIT BREAKERS ARE 00% CONTINUOUS DUTY RATED WITH 4 VOLT DC SHUNT TRIPS AND A/B AUXILIARY CONTACTS. OPTIONAL COMPONENTS SEPARATE CONDUITS. TWO WIRE + GROUND UPS INPUT AND OUTPUT CONDUCTORS MUST BE IN SEPARATE AMPERE RATINGS. UPS AND STATIC BYPASS WITHSTAND 00,000 SYMMETRICAL AMPERES. INSTALLATION MUST COMPLY WITH ALL APPLICABLE NATIONAL AND LOCAL CODES. 7

12 External disconnection switches Warning: The UPS has no builtin disconnect devices to switch off external AC (Q and Q5) and DC (Q7 and Q8) input power. Ensure that the disconnect devices are available as separate components for this installation. Note: The installer must provide each external disconnect device for this UPS system with labels displaying the following text: Isolate the Uninterruptible Power Supply (UPS) as instructed in the User Guide before working on the circuit. Input/Output wiring precautions Warning: Only personnel trained in the construction and operation of the equipment, and the electrical and mechanical hazards involved, must install or remove system components. Warning: Supply the UPS from a dedicated, grounded, 3wire Wye service. Caution: All wiring must be in accordance with applicable national and/or local electrical codes. Note: Use only ULapproved cables and cable lugs. Use only stranded copper conductors. Refer to National Electrical Code for wiring and protection. See Recommended cable, bolt and lug sizes. 8

13 Top Cable Entry Preparing for top cable entry (default) Cable entry in top cover of Input/Output Section. Top view M6 Bolt Battery cable entry Battery cable entry.75 in / mm.3 in / 58 mm.75 in / mm AC IN cable entry AC OUT cable entry IN/OUT power cable (top entry) BAT BAT Top view AC IN AC OUT 90 L3 IN 95 9 L IN 94 9 L IN 93 L3 OUT L OUT L OUT L IN L IN L OUT L OUT L3 IN L3 OUT. Loosen the 8 bolts in cable entry covers. Drill holes for conduits in areas shown. Refit the covers and install the conduits.. Install cable lugs on busbars. Use M bolts. 9

14 Battery cable connections (top cable entry) Warning: Make sure that the battery breakers are open (OFF) prior to running the cables. Caution: For battery installation and maintenance instructions, refer to the battery manufacturer s installation manual. Caution: Overcurrent protection for the battery circuit is required by code. The minimum DC voltage rating of the battery supply overcurrent protection device is 500 V. Note: Overcurrent protection for the battery circuit is required by code. Note: BAT and BAT cables MUST be run in separate conduits. 0

15 Top view of Input/Output Section Battery cable entry Battery cable entry.75 in / mm.3 in / 58 mm.75 in / mm AC IN cable entry AC OUT cable entry IN/OUT power cable (top entry) Battery Battery (BAT +/) (BAT +/) BAT BAT + BAT BAT + L In L Out L In L Out L3 In BAT + BAT L3 Out BAT + BAT Front view of Input/Output Section. Feed the battery cables through the top of Input/Output Section.. Connect cables from battery system as illustrated. 3. Connect cables from battery system as illustrated.

16 Ground and AC cable connections (top cable entry) Equipment grounding cables for Battery and AC Out Output circuit grounding bar Grounding electrode conductors (red) for Battery & AC IN Midpoint bonding jumper.75 in / mm.75 in / mm.3 in / 58 mm. Feed the AC and ground cables through the top of Input/Output Section as illustrated.. Connect the cables as illustrated.

17 Bottom Cable Entry Preparing for bottom cable entry Cable entry in bottom cover of Input/Output Section. Top view M6 Bolt Battery cable entry Battery cable entry.75 in / mm.3 in / 58 mm.75 in / mm AC IN cable entry AC OUT cable entry Top view Front view BAT BAT M4 M4 M4 M0 M0 M0 AC IN 90 L3 IN L IN 9 L IN M0 AC OUT 95 L3 OUT L OUT 93 L OUT M4 M0 M0 M0 L IN L OUT L IN 9 94 L OUT L3 IN 9 93 L3 OUT BAT BAT Top view AC IN AC OUT 90 9 L3 IN L IN L IN 95 L3 OUT L OUT 93 L OUT IN/OUT power cable (bottom entry).. Preparation for bottom cable entry 3

18 a. Loosen bolts of both cable entry covers and remove. b. Drill holes for conduits for AC, Battery, and Output circuit grounding electrode cable in areas shown. c. Install conduits. d. Remount covers.. Interchange of AC IN busbars for bottom entry a. Remove nuts from M4 bolts at busbars 90 and 9. b. Remove bolt, washer and fuse. c. Remove bolts from M0 at busbars 90 and 9. d. Remove busbars 90 and 9 at AC IN. e. Move the two front insulators in the topmost busbar position two stud positions to the front. f. Move the two front insulators in the lowest busbar position two stud positions to the rear. g. Install busbar 90 in original position of busbar 9. h. Install busbar 9 in original position of busbar 90. i. Reattach bolts at busbars 90 and 9. j. Install cable lugs on busbars using M bolts. 3. Interchange of AC OUT busbars for bottom entry a. Remove nuts from M4 bolts at busbars 93 and 95. b. Remove bolt, washer and fuse. c. Remove bolts from M0 at busbars 93 and 95. d. Remove busbars 93 and 95 at AC OUT. e. Move the two front insulators in the topmost busbar position two stud positions to the front. f. Move the two front insulators in the lowest busbar position two stud positions to the rear. g. Install busbar 93 in original position of busbar 95. h. Install busbar 95 in original position of busbar 93. i. Reattach bolts at busbars 93 and 95. j. Install cable lugs on busbars using M bolts. 4. Moving busbar for grounding a. Move busbar for grounding from upper right corner to lower left corner as illustrated. Battery cable connections (bottom cable entry) Warning: Make sure that the battery breakers are open (OFF) prior to running the cables. Caution: For battery installation and maintenance instructions, refer to the battery manufacturer s installation manual. Caution: Overcurrent protection for the battery circuit is required by code. The minimum DC voltage rating of the battery supply overcurrent protection device is 500 V. 4

19 Note: Overcurrent protection for the battery circuit is required by code. Note: BAT and BAT cables MUST be run in separate conduits. Top view of Input/Output Section Battery cable entry Battery cable entry.75 in / mm.3 in / 58 mm.75 in / mm AC IN cable entry AC OUT cable entry Front view of Input/Output Section BAT BAT + BAT BAT + L In L Out L In L Out L3 In L3 Out BAT + BAT BAT + BAT Battery BAT +/) Battery (BAT +/) IN/OUT power cable (bottom entry). Feed the battery cables through the bottom of Input/Output Section.. Connect cables from battery system as illustrated. 3. Connect cables from battery system as illustrated. 5

20 Ground and AC cable connections (bottom cable entry) Midpoint bonding jumper Output circuit grounding bar Equipment grounding cables for Battery & AC IN Equipment grounding cables for Battery & AC OUT Equipment grounding bar Battery Battery.75 in / mm.3 in / 58 mm.75 in / mm. Feed the AC and ground cables through the bottom of Input/Output Section as illustrated.. Connect cables as illustrated. Bypass Static Switch Wiring Warning: Use only manual reset protection as input overcurrent protection. 6

21 Warning: Overcurrent protection required by code. Warning: The UPS has no builtin disconnect devices to switch off external AC (Q and Q5) and DC (Q7 and Q8) input power. Ensure that the disconnect devices are available as separate components for this installation. Caution: The External Bypass Static Switch is not provided with builtin backfeed protection. The breaker is controlled from the External Bypass SSW and will be tripped in case of backfeed. Note: The installer must provide each external disconnect device for this UPS system with labels displaying the following text: Isolate the Uninterruptible Power Supply (UPS) as instructed in the User Guide before working on the circuit. Note: The installation of the External Bypass Static Switch must comply with local and national codes. Note: Run matched set of phase cables in the same cable run(s). Do not separate phases into different cable runs. For information on cable lugs, cable ratings, overcurrent protection and the disconnection switches, refer to Specifications. 7

22 X008A X008B X00 X007 X0 X0 X0 X0 X03 X04A X405 X07 X04B UPS Summary ~ ~ Normal Normal Top cable entry Top view of top cable entry Top view of AC IN & OUT cable connections L IN L OUT L IN L OUT L3 IN L3 OUT PE Port for communication cables L IN L OUT L IN L OUT L3 IN L3 OUT.75 in / mm.75 in / mm.3 in / 58 mm. Loosen the 8 bolts to remove top cover. Note: No drilling or cutting should take place over the top of the UPS.. Drill holes for conduits. Refit the covers. Install the conduits. 3. Feed cables through conduits. Connect cables at cable connection points as illustrated. 4. Connect grounding electrode conductor to busbar locations as shown. 8

23 X008A X008B X00 X007 X0 X0 X0 X0 X03 X04A X405 X07 X04B UPS Summary ~ ~ Normal Normal Bottom cable entry Top view of bottom cable entry Top view of AC IN & OUT bottom cable connections L IN L OUT L IN L OUT L3 IN L3 OUT Communication cable Port L IN L OUT L IN L OUT L3 IN L3 OUT PE.75 in / mm.3 in / 58 mm.75 in / mm. Loosen the 8 bolts to remove bottom cover. Note: No drilling or cutting should take place inside the UPS.. Drill holes for conduits. Refit the covers. Install the conduits. 3. Feed cables through conduits. Connect cables at cable connection points as illustrated. 4. Connect grounding electrode conductor to busbar locations as shown. 9

24 Communication Cable Overview External Bypass Static Switch Terminator 0N0765 Maintenance Bypass Panel Relay output Connection plane 0P0957 X34A X77 X3 Q 6 Q 5 X34A X77 X8 X9 0 9 X34B X75 Norm.op 3 4 X70 MBP CAN I/O board 0P4533 X74 Earth fault sensor X C + Note C X6B X7B X6A X7A X30 X8 X9 EMO (Display) Q 4 Q 3 Q Q MBP Breakers X73 Lamps X7 X Note Terminator 0N0765 H3 H4 H5 H6 Q5 4VDC Q6 Shunt trip for back feed protection + External Lamp supply V DCor VDC Max. 50V AC 5A Connection plane 0P0957 X6B X7B X6A X7A UPS Backfeed protection X34A EPO out X77 X3 X30 X8 X9 EMO (Display) External EPO placed on wall Note X34B X34A X73 X77 MBP Breakers X X7 Lamps X9 Norm.op X75 MBP CAN I/O board 0P4533 Relay output Earth fault sensor X X70 X78 X Maintenance Bypass Panel Note C + C Q Q 4VDC Shunt trip EPO out X85 X33A Q7 Q8 3 4 X8 3 4 X80 Battery CAN I/O board X85 ID 0 0P45 X33A X86 X33B H7 3 X83 H X84 X8 Fuse Fuse Fuse3 Fuse Note UVR Q8 + UVR Q7 + Temp sensor NTC + Temp sensor NTC + Note : Contact APC Application Team for correct sizing. Note : H7, H8 = 5V LED Note 3: Q, Q4 and Q6 are optional. If Q is not present pins 3 and 4 must be shorted on both boards. If Q4 is not present pins 7 and 8 must be shorted on both boards. If Q6 is not present pins and must be shorted on both boards. 0

25 Relay Boards Location of relay boards The relay boards are connected to the bottom cover plate of the Control Section. Relay board Relay board Relay board communication cables Control Section Backplane X008A Fan CAN X008A

26 Relay board connections Relay Function Mode Special Comments Output Common alarm Fail safe Output Normal operation Active on Output 3 Bypass operation Active on Output 4 Battery operation Active on Output 5 V DC out of tolerance Fail safe Output 6 Battery conditon fault Fail safe Battery fault detected by battery monitor Output 7 Maintenance bypass operation Active on Output 8 Mains out of tolerance Fail safe Output 9 Bypass out of tolerance Fail safe Output 0 Output out of tolerance Fail safe Output MCCB open Fail safe Battery breakers open Output System overload Fail safe Output 3 Good utility Active on If UPS goes into bypass, this relay goes on without delay Output 4 Boost charge active Fail safe Output 5 Fan fault Fail safe Output 6 Temperature fault Fail safe Temperature switch active or faulty temperature sensor Input Generator active Master will handle signal Input for indicating that a generator is active. This will be used to reduce the charge power Input Battery room ventilation fault Individual Input for indicating that the ventilation in battery rooms is defect. This will be used to reduce the charge power Input 3 DC Ground Fault Detection Individual Input 4 Reserved for future use Master will handle signal Input 5 Plant clock synchronization Master will handle signal Input for real time clock synchronization Input 6 Power Tie detection Master will handle signal Input from PLC to detect if Power Tie is active

27 Relay Function Mode Special Comments Input 7 Input 8 Reserved for future use Reserved for future use Relay board connections Relay Function Mode Special Comments Output Info level alarm Fail safe Output Warning level alarm Fail safe Output 3 Severe level alarm Fail safe Output 4 Input frequency too high Fail safe Output 5 Input frequency too low Fail safe Output 6 Output 7 Output frequency too high Output frequency too low Fail safe Fail safe Output 8 Bypass source fault Fail safe Output 9 Close Q7 pulse Active on No delay Output 0 Close Q8 pulse Active on No delay Output Power Tie mode active Active on No delay Output Close Q Fail safe No delay Output 3 Output 4 Output 5 Output 6 Input Input Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use Reserved for future use 3

28

29 Specifications LowImpedance/HighImpedance Grounding The Symmetra MW is easily integrated into either a lowimpedance (solidly) grounded Wye system, or a highimpedance grounded system. In a lowimpedance grounded system (most common), the power source (utility, generator, or UPS) is solidly grounded. In the event of a downstream ground fault, the fault current will have a path back to the source, and the overcurrent device feeding the faulted part of the installation will trip and isolate the fault. In a highimpedance grounded system, the source is grounded with an impedance (grounding resistor). In the event of a downstream fault, the fault current will be limited by the impedance of the grounding resistor. The value of a highimpedance system is its ability to maintain operation with a given system fault to ground, i.e. the overcurrent device will only trip at linetoline faults or double ground faults. For a highimpedance system to provide enhanced power system reliability and availability, a groundfault monitoring/alarm system is required. Lowimpedance grounding For lowimpedance grounding, verify the presence of the copper midpoint bonding jumper. For location of the jumper, see Ground and AC cable connection in Installation Manual. Connect the output circuit grounding electrode conductor to a grounding electrode in accordance with NEC 999, article 506. Note: Grounding electrode conductor to be supplied by the customer Highimpedance grounding For highimpedance grounding, remove the preinstalled copper midpoint bonding jumper. For location of the jumper, see Ground and AC cable connection in Installation Manual. Install groundfault detection circuit in accordance with NEC 999, article Note: For highimpedance grounding, the installation must include groundfault detection circuitry. From an external grounding resistor, and through a separate conduit, connect a cable to the output circuit grounding bar. 5

30 Electrical Specification Installation Planning Data Maintenance Bypass Panel Q3 Q5 External Bypass SSW Q6 Optional Service (480V 3phase, 3 wire grounded Wye) Q UPS Q Optional Q4 Optional Output (480V 3phase, 3wire only) Battery Q7 Breaker Q8 Battery Breaker Note: The installation is a typical installation including ancillary equipment, which is available from APC. Note: UPS and External Bypass Static feed must be generated from synchronized sources. Warning: Supply the UPS from a dedicated, grounded 3wire Wye service. Warning: The UPS has no builtin disconnect devices to switch off external AC (Q and Q5) and DC (Q7 and Q8) input power. Ensure that the disconnect devices are available as separate components for this installation. Caution: Ensure clockwise phase rotation (L, L, L3) of input voltages. Caution: AC and DC disconnect switches and overcurent protection must be included in the installation. Note: All wiring must comply with all applicable national and/or local electrical codes. 6

31 Note: Max. prospective RMS shortcircuit current on input terminals: 00 ka. Note: Max. prospective RMS shortcircuit current on battery terminals: 50 ka. AC Input AC Input Input Rating 000 kw/kva Power Factor Input Voltage 480 V Input Frequency 60 Hz Nominal Input Current (note ) 40 A Maximum Input Current (note ) 364 A Input Current Limitation (note 3) 564 A Recommended Cable per phase (notes 4, 6, 7, a, b, c) kcmil DC Input DC Input Nominal Voltage (note 5) I Nom Discharge (note 8) I Max Discharge (note 9) Recommended cable (per pole) x 384 V 356 A 595 A kcmil Caution: Overcurrent protection for the battery circuit is required by code. The minimum DC voltage rating of the battery supply overcurrent protection device is 500 V. AC Output AC Output Voltage Current Nom Max (note ) Recommended cable (per phase) 480 V 03 A 504 A kcmil 7

32 AC Input External Bypass SSW The External Bypass SSW is designed to accommodate a continuous overload of 5%. AC Input External Bypass SSW External Bypass SSW Max Input Current (00% load) 03 A Heat Dissipation Notes 05.5 kbtu/hr (note 0). Nominal (Nom): Input current based on rated load.. Maximum (Max): Input current based on full battery recharge + nominal input voltage + rated load. 3. Current limitation (A) through electronic current limiting is based on full battery recharge + nominal load and 5% input voltage (see Required Breaker Settings ). 4. Input, Output and Battery and Battery circuit cables shall be run in separate conduits or raceways. Cables shall be rated at 600 V as a minimum. 5. Nominal battery voltage at.0 volts/cell. 6. Recommendation: All cables shall be sized in accordance with 00 NEC 09 FPN No. 4 branch feeder voltage drop of 3%. Voltage drop not considered in above chart. Applicationspecific Input Cable Ampacity may vary from above chart. 7. Equipment Grounding Conductors shall be sized in accordance with Table 50 of the 00 NEC and shall be installed in accordance with Article 50 Section VI and Section VII of the 00 NEC. Grounding Electrode Conductors shall be sized in accordance with Article and Table of the 00 NEC and should be installed in accordance with Article 50 Section III of the 00 NEC. 8. Nominal Battery Discharge current based on rated load, and nominal battery voltage. 9. Maximum Battery Discharge current based on rated load at end of discharge. 0.Heat dissipation calculated at rated load capacity..this current is at 5% of rated load and is electronically currentlimited to a maximum of 0 minutes. This value is only provided so the engineer can ensure that the selected AC output circuit overcurrent device s timecurrent characteristic will support this condition. a. Temperature rating of conductors: 94 o F (90 o C). Reference: Table 306 of NEC, 75 o C column. Use only copper conductors. 67 o F (75 o C) cable terminal connectors assumed. b. Reference: NEC Handbook 00. Consult local codes for possible variations. c. All cable ratings are supplied as guidelines only. These guidelines are recommendations only, and should not be considered substitutes for review and compliance with NEC, national, or local codes. Consult with your licensed engineer for sitespecific applications. 86 o F (30 o C) assumed. Overcurrent protection provided by others. 8

33 Table Table 306 (National Electrical Code) National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, MA. Allowable Ampacities of Insulated Conductors rated 0 Through 000 Volts, 60 o C Through to 90 o C (40 o F Through 94 o F), Not More Than Three CurrentCarrying Conductors in Raceway, Cable, or Earth (Directly Buried), Based on Ambient Temperature of 30 o C (86 o F). Size Temperature Rating of Cables (See Table 303) Size 60 o C (40 o F) 75 o C (67 o F) 90 o C (94 o F) 60 o C (40 o F) 75 o C (67 o F) 90 o C (94 o F) AWG or kcmil Types TW,UF Types FEPW,RH,RH W,THHW, THW,THWN, XHHW, USE,ZW Types TBS,SA,SIS,FEP, FEPB,MI,RHH, RHW,THHN, THHW,THW, THWN,USE, XHH,XHHW,XH HW,ZW Types TW,UF Types RH,RHW,TH HW,THW, THWN, XHHW,USE Types TBS,SA,SIS,TH HN,THHW,TH W,THWN, RHH,RHW, USE,XHH, XHHW, XHHW,ZW AWG or kcmil Copper Aluminium or CopperClad Aluminium 8 6 4* * 0* * 0* /0 /0 3/0 4/ /0 /0 3/0 4/ CORRECTION FACTORS Ambient Temp. ( o C) For ambient temperatures other than 30 o C (86 o F), multiply the allowable Ampacities shown above by the appropriate factor shown below Ambient Temp. ( o F) Reprinted with permission from NFPA 70005, National Electrical Code, Copyright 004, National Fire Protection Association, Quincy, MA 069. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. 9

34 Size Temperature Rating of Cables (See Table 303) Size 60 o C (40 o F) 75 o C (67 o F) 90 o C (94 o F) 60 o C (40 o F) 75 o C (67 o F) 90 o C (94 o F) AWG or kcmil Types TW,UF Types FEPW,RH,RH W,THHW, THW,THWN, XHHW, USE,ZW Types TBS,SA,SIS,FEP, FEPB,MI,RHH, RHW,THHN, THHW,THW, THWN,USE, XHH,XHHW,XH HW,ZW Types TW,UF Types RH,RHW,TH HW,THW, THWN, XHHW,USE Types TBS,SA,SIS,TH HN,THHW,TH W,THWN, RHH,RHW, USE,XHH, XHHW, XHHW,ZW AWG or kcmil Copper Aluminium or CopperClad Aluminium Reprinted with permission from NFPA 70005, National Electrical Code, Copyright 004, National Fire Protection Association, Quincy, MA 069. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. Recommended cable, bolt, and lug sizes Cable Size Bolt hole size Hole spacing Lug width Lug P/N ()() Crimping Tool and Dies 400 kcmil 0.5 in/.7 mm.75 in/44.45 mm.39 in/35.3 mm Panduit LCD4006 (or equivalent) 500 kcmil 0.5 in/.7 mm.75 in/44.45 mm.54 in/39. mm Panduit LCD5006 (or equivalent) 600 kcmil 0.5 in/.7 mm.75 in/44.45 mm.70 in/43.8 mm Panduit LCD6006 (or equivalent) Manufacturer recommended crimping tool and dies. Manufacturer recommended crimping tool and dies. Manufacturer recommended crimping tool and dies. Note: Cable lugs are not supplied. 30

35 Torque specifications Torque specifications Bolt Size M8 Bolt Size M0 Bolt Size M Bolt Size M4 0 lbfft/3.5 Nm lbfft/30 Nm 37 lbfft/50 Nm 55 lbfft/75 Nm Required Breaker Settings The Symmetra MW is a faulttolerant system capable of handling and surviving overloads and internal/ external faults. The overload performances and fault clearings are possible when the system meets specified minimum requirements for breaker settings. A proper breaker coordination study is required to ensure the highest availability of the UPS. This breaker coordination study should be performed focusing on maintaining the fault tolerant characteristics of the Symmetra MW. The following tables provide the optimum settings for the input and output breakers. The settings are specified in the tables below, but some of them can also be found in the Electrical Specification section. See separate manual on parallel systems for information on required breaker settings in parallel systems. Input and upstream breakers Q, Q5, and any upstream breaker Duration [S] Current [A] Total load [%] Event/Operation < ka* Internal fault clearing/ Instantaneous trip setting 880** 30 Overload online Online Online + Max. Battery Charge * In the absence of a coordination study conducted by a professional engineer, the recommended instantaneous trip setting for breakers Q, Q, Q4, Q5, and Q6 is 8 ka. ** Only applicable to Q 3

36 Output and downstream breakers Q, Q4, Q6 Duration [S] Current [A] Total load [%] Event/Operation < ka* Internal fault clearing/ Instantaneous trip setting ** 00 Overload online ** 5 Overload online Online * In the absence of a coordination study conducted by a professional engineer, the recommended instantaneous trip setting for breakers Q, Q, Q4, Q5, and Q6 is 8 ka. ** Only applicable to Q and Q4 In the absence of a proper breaker coordination study and if only the actual Ip on the unit s input terminals is known, this table must be used to optimize the instantaneous trip setting or to choose a breaker with a usable fixed instantaneous trip value. Ip* [ka] I peak letthrough [ka] I setting [ka] * Ip = Abridgment for Prospective shortcircuit current. This is the current that would flow in the fault circuit is the fuse was replaced by a link with an infinitely small impedance 8 ka is the maximum peak letthrough current (including safety factor) present during clearing of an internal fault in a 00 kw section or a power module. This maximum peak letthrough current is based on and applicable to utility with prospective shortcircuit currents (Ip) up to 00 ka. During or after a controlled fault clearing, none of the breakers are allowed to trip on the instantaneous trip setting below the specified value. This is also applicable to the upstream breakers, and a check of the instantaneous trip setting in this part of the installation is required. The instantaneous trip setting calculated by a professional engineer in a breaker cooardination study must not disable the functionality of clearing and surviving an internal fault unless there is a written agreement between APC by Schneider Electric and the customer. By ensuring the unit s fault clearing ability (survival skills) i.e. using the correct instantaneous trip settings in the switch gear (installation), maximum power availability in normal operation is obtained for the critical load. Note: The instantaneous trip setting can be calculated when utility Ip is known. An incorrect trip setting can result in limiting the system functionality and jeopardize the load support. 3

37 Note: The instantaneous trip setting must not be derated even though the UPS system is derated in system output power. The system size has no influence on the instantaneous trip setting. Note: For derated systems, the APC Application Team can provide the correct breaker settings and breaker frame sizes. Note: For upstream breakers not mentioned in the table, the APC Application Team can provide the correct breaker settings for online, overload, and trip currents. The following diagram shows a dual utility system in which the upstream breakers are named Q. Correct settings of upstream breaker settings are mandatory. The system can also be configured as a single utility system. Dual Utility Installation Q3 T Q Q5 Q6 T Q Q Q Q4 General Specifications 480 V Backfeed protection Humidity Builtin in the UPS Max. 95% noncondensing Protection class NEMA Safety Emission and immunity UL 778 listed FCC part 5, sub part J Class A (conducted/radiated) 33

38

39

40 APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. Global support searching APC Knowledge Base and using esupport. Contact the APC Customer Support Center by telephone or . Local, countryspecific centers: go to for contact information. For information on how to obtain local customer support, contact the APC representative or other distributors from whom you purchased your APC product. Entire contents copyright 009 American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and Symmetra are trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 9904F00 *9904F00* 4/009

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220 Table K. Input/ Ratings & External Wiring Requirements for the 9390-/ Units Rating 50/0 Hz Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input Rectifier (0.98 min. pf) plus Recharge Current

More information

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems UNITY/I TM UT3K, UT4K, UT5K and UT8K Single-Phase Uninterruptible Power Systems Installation Manual MLS-0351C-OL Copyright 1994-1997 Best Power. All rights reserved. å IMPORTANT SAFETY INSTRUCTIONS! SAVE

More information

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected. CONDUCTOR SHORT-CIRCUIT PROTECTION Introduction: This paper analyzes the protection of wire from fault currents. It gives the specifier the necessary information regarding the short-circuit current rating

More information

TOSHIBA International Corp

TOSHIBA International Corp TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification

More information

InfraStruXure Manager v4.x Addendum: Building Management System Integration

InfraStruXure Manager v4.x Addendum: Building Management System Integration InfraStruXure Manager v4.x Addendum: Building Management System Integration Introduction This addendum explains the integration of the APC InfraStruXure Manager Appliance with a Building Management System

More information

A53106 SERIES DC-TO-DC CONVERTER

A53106 SERIES DC-TO-DC CONVERTER INSTALLATION & MAINTENANCE A53106 SERIES DC-TO-DC CONVERTER AUGUST 2011, REVISED AUGUST 2014 DOCUMENT NO. COM-00-04-20 VERSION C.1 Siemens Industry, Inc., Rail Automation 9568 Archibald Ave., Suite 100,

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

JBus/Modbus Communication Card

JBus/Modbus Communication Card JBus/Modbus Communication Card Installation and Operation 05/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries

More information

JBUS/MODBUS communication card

JBUS/MODBUS communication card JBUS/MODBUS communication card JBUS/MODBUS Installation and user manual 66061 51029066EN/BF - Page 1 Page 2-51029066EN/BF Introduction Thank you for selecting an APC by Schneider Electric product to protect

More information

high RESISTANCE GROUNDING SYSTEM the power to protect www. ElectricalPartManuals. com Instruction Manual C-102

high RESISTANCE GROUNDING SYSTEM the power to protect www. ElectricalPartManuals. com Instruction Manual C-102 G e m i n i high RESISTANCE GROUNDING SYSTEM the power to protect Instruction Manual C-102 HIGH RESISTANCE GROUNDING SYSTEM Gemini is a unique, fail safe, all-in-one neutral grounding system, combining

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

Ground Fault Location. Turbo Sleuth. Instruction Manual

Ground Fault Location. Turbo Sleuth. Instruction Manual Ground Fault Location Turbo Sleuth Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR 737-4787 www.ipc-resistors.com

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web: Phone: (818) 734-5300 Fax: (818) 734-5320 Web: www.capstoneturbine.com Technical Reference Capstone MicroTurbine Electrical Installation 410009 Rev F (October 2013) Page 1 of 31 Capstone Turbine Corporation

More information

Short-Circuit Current Calculations

Short-Circuit Current Calculations Basic Point-to-Point Calculation Procedure Step. Determine the transformer full load amps (F.L.A.) from either the nameplate, the following formulas or Table : Multiplier = 00 *% Z transformer Step 2.

More information

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate, service or maintain

More information

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual IM-LZSA500-3 January 2008 Revision H Table of Contents LZS-A500-3 Power Supply 1) Safety and Recommended Practices 2 1.1 General

More information

3Ø Short-Circuit Calculations

3Ø Short-Circuit Calculations 3Ø Short-Circuit Calculations Why Short-Circuit Calculations Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective

More information

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 690 Volts, 50Hz Page 2 of 24 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Typical results of the Sine Wave Filters 4. Transportation,

More information

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual Model 3725/2M Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any

More information

Gutor PxW AC UPS Designed for North American Market

Gutor PxW AC UPS Designed for North American Market Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com

More information

high RESISTANCE GROUNDING SYSTEM the power to protect SLEUTH Instruction Manual C-408EM

high RESISTANCE GROUNDING SYSTEM the power to protect SLEUTH Instruction Manual C-408EM SLEUTH high RESISTANCE GROUNDING SYSTEM SLEUTH the power to protect Instruction Manual C-408EM HIGH RESISTANCE GROUNDING Sleuth Protecting your equipment and processes from damaging ground faults, a resistor

More information

Wisconsin Contractors Institute Continuing Education

Wisconsin Contractors Institute Continuing Education IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you

More information

Dynamo Brushless DC Motor and GreenDriveTM Manual

Dynamo Brushless DC Motor and GreenDriveTM Manual Dynamo Brushless DC Motor and GreenDriveTM Manual This manual was developed as a guide for use by FIRST Robotics Teams using Controller Part Number 840205-000 in conjunction with the Nidec Dynamo BLDC

More information

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL 1.1 SUMMARY Liebert NX UPS GUIDE SPECIFICATIONS 40-80kVA, 80-120kVA and 160-200kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL This specification defines the electrical and mechanical

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

PACSystems* RX3i IC695MDL765

PACSystems* RX3i IC695MDL765 March 2011 PACSystems* RX3i IC695MDL765 Digital Output Module with Diagnostics 16-Channel The 24/125 volt DC 2A Smart Digital Output module, IC695MDL765, provides 16 discrete outputs in two isolated groups

More information

Table G. INPUT/OUTPUT Ratings & External Wiring Requirements for the /160 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Table G. INPUT/OUTPUT Ratings & External Wiring Requirements for the /160 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220 Table G. INPUT/OUTPUT Ratings & External Wiring Requirements for the 9390/ Units Rating 50/60 Hz Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input A Input to UPS Rectifier (0.98 min. pf)

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5 Applied Grounding and Bonding Paul Dobrowsky Member NEC Panel 5 1 Introduction This presentation is a representative sample from the following Chapters of Applied Grounding and Bonding. Chapter 1, Introduction

More information

CP /240-MC4 User Manual

CP /240-MC4 User Manual CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Jan 2014 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...

More information

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850

More information

EN 50178, IEC

EN 50178, IEC Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230

More information

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services Introduction The topic of system grounding is extremely important, as it affects the susceptibility of the system to voltage

More information

Datawave Magnetic Synthesizer

Datawave Magnetic Synthesizer POWER PROTECTION Datawave Magnetic Synthesizer 100 kva to 200 kva; 50 and 60 Hz Installation, Operation, & Maintenance Manual TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS............................................1

More information

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The

More information

GE FANUC Spares. GE Fanuc Automation. Stepping Motor Cube with Pulse and Direction Interface. Programmable Control Products.

GE FANUC Spares. GE Fanuc Automation. Stepping Motor Cube with Pulse and Direction Interface. Programmable Control Products. GE Fanuc Automation Programmable Control Products Stepping Motor Cube with Pulse and Direction Interface User s Manual July 2002 GE FANUC Spares Warnings, Cautions, and Notes as Used in this Publication

More information

SPECIFICATION. Online UPS 3000VA

SPECIFICATION. Online UPS 3000VA Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

2-Slot Desktop Chassis (DC) Extended Temperature

2-Slot Desktop Chassis (DC) Extended Temperature APRIL 2008 LMC5202A 2-Slot Desktop Chassis (DC) Extended Temperature Copyright 2008. Black Box Corporation. All rights reserved 50 80105BB 01 A0 1000 Park Drive Lawrence, PA 35055 1018 724 746 5500 Fax

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase The complete Liebert ITA2 MBC user manual is available at Vertiv s Web site, www.vertivco.com/en-us/products-catalog/critical-power/uninterruptible-powersupplies-ups/

More information

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor NOsparc MHXAC1F120 MHXAC1F240 MHXAC1F480 PATENTS AND PATENTS PENDING Contact Arc Suppressor Contact Arc Suppression for AC Power Relays, Contactors, and Snap-Action Switches User Manual 104-0017E 2014,

More information

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

IC800SSD Hardware Manual Pub 348R5. for models. A publication of IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays Dual-Source Power Supply Addendum to I.B. 17555 Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays Table of Contents Page 1.0 Introduction...1 2.0 General

More information

Electronic Circuit Protector ESX10-T

Electronic Circuit Protector ESX10-T Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection: Utility Systems Technologies, Inc. Sag Fighter TM Deep Voltage Sag Protection: D e e p Vo l t a g e S a g P r o t e c t i o n For three phase application: Q u a l i t y P o w e r. B e t t e r B u s i n

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SG Series 80 100 120 kva 400 Vac CE Series 0 Date of issue: 01.11.2007 SGSE_080_UPS_GE_01a SGSE_100-120_UPS_GE_01a

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

90-NET. Series CHLORIDE POWER PROTECTION. THREE PHASE Uninterruptible Power System. Owner s Manual. P/N 10H52171UM01 Rev. 3

90-NET. Series CHLORIDE POWER PROTECTION. THREE PHASE Uninterruptible Power System. Owner s Manual. P/N 10H52171UM01 Rev. 3 90-NET Series CHLORIDE POWER PROTECTION THREE PHASE Uninterruptible Power System Owner s Manual P/N 10H52171UM01 Rev. 3 10H52171UM01 - Revision 3-12/4/07 - page ii 10H52171UM01 - Revision 3-12/4/07 - page

More information

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 October 2017 RSTI-EP Slice I/O Specialty Modules EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 Module Status LED Channel Status LED GE provides several RSTi-EP specialty modules, which

More information

Tel: Fax:

Tel: Fax: Grid Tie Solar Inverter Operator's Manual SG-4000 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS To reduce the risk of electrical shock and to ensure safe installation and operation of Grid Tie

More information

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings SOLAR MICROINVERTER/M STANDARD PLAN - COMPREHENSIVE Microinverter and M Systems for One- and Two- Family Dwellings SCOPE: Use this plan ONLY for systems using utility-interactive Microinverters or Modules

More information

This manual was downloaded on (0) COMPATIBLE WITH VERSION 6 SOFTWARE

This manual was downloaded on (0) COMPATIBLE WITH VERSION 6 SOFTWARE EUROTHERM DRIVES 584S Frequency Inverter Product Manual COMPATIBLE WITH VERSION 6 SOFTWARE Copyright Eurotherm Drives Limited 2000 All rights strictly reserved. No part of this document may be stored in

More information

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.1 SUMMARY DISCONTINUED PRODUCT GUIDE SPECIFICATIONS 15-75 kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL These specifications describe requirements for a complete power conditioning and

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller. The TCP3500 series is an AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (No Fans) makes this power supply series suitable for a wide variety of Industrial

More information

R&D TECHNICAL SPECIFI

R&D TECHNICAL SPECIFI INTRODUCTION Present document defines technical specs of a three phase UPS covering the power range from 20 to 30 kva ON-LINE DOUBLE CONVERSION Uninterruptible Power Supply Systems with forced ventilation

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

American Electrical Institute

American Electrical Institute American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article

More information

NetSure ITM. Contents 1. Site Planning Data 2. One Line Diagram 3. System Outline Drawings 4. Connection Details

NetSure ITM. Contents 1. Site Planning Data 2. One Line Diagram 3. System Outline Drawings 4. Connection Details A technical manual from the experts in Business-Critical Continuity NetSure ITM Site Planning Data and System Drawings 48V DC UPS Section 6037 (Issue 10, October 21, 2010) Contents 1. Site Planning Data

More information

High Frequency Sinewave Guardian TM Filter

High Frequency Sinewave Guardian TM Filter High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode

More information

MNL-5Rxx. Application. Model Chart. TAC I/A Series MicroNet MN 50 Controller Installation Instructions

MNL-5Rxx. Application. Model Chart. TAC I/A Series MicroNet MN 50 Controller Installation Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MNL-5Rxx TAC I/A Series MicroNet MN 50 Controller Installation Instructions Application The TAC I/A Series MicroNet MNL-5Rxx

More information

High Frequency SineWave Guardian TM Filter

High Frequency SineWave Guardian TM Filter High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference

More information

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference Electromagnetic Compatibility and Electrical Safety GR-1089-CORE Table of Contents Table of Contents 1 Introduction 1.1 Purpose and Scope.................................. 1 1 1.2 Items Not Covered in

More information

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM SECTION 263353 - THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM PART 1 GENERAL 1.1 SUMMARY A. This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty three-phase,

More information

8902/RE and 8902/RR Resolver Speed Feedback Options

8902/RE and 8902/RR Resolver Speed Feedback Options 8902/RE and 8902/RR Resolver Speed Feedback Options Technical Manual HA469251U002 Issue 1 Compatible with Version 2.x and 3.x Software Copyright 2009 Parker SSD Drives, a division of Parker Hannifin Ltd.

More information

Electrical Wiring: Commercial, Seventh Canadian Edition

Electrical Wiring: Commercial, Seventh Canadian Edition Electrical Wiring Commercial Canadian 7th Edition Mullin SOLUTIONS MANUAL Full download at: https://testbankreal.com/download/electrical-wiring-commercialcanadian-7th-edition-mullin-solutions-manual/ Unit

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product

More information

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys TSX Series Modicon Manuals Presented by: Modicon PLC Schneider Electric Quantum Modicon Gould Gettys For Product Needs: Email: sales@modiconplc.com Call: 1-800-691-8511 Fax: 919-415-1614 ModiconPLC.com

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

MODEL 3810/2 Line Impedance Stabilization Network

MODEL 3810/2 Line Impedance Stabilization Network EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047

More information

VLT 5000/6000 Series. Contents

VLT 5000/6000 Series. Contents Contents Introduction to VLT 5300-5500 / VLT 6350-6550... 2 General warning... 2 Introduction... 3 Transportation and unpacking... 4 Key diagram forvlt 5300-5500 380-500 V and VLT 6350-6550 380-460 V...

More information

Installing the IPS 4240 and the IPS 4255

Installing the IPS 4240 and the IPS 4255 CHAPTER 2 Installing the IPS 4240 and the IPS 4255 All IPS platforms allow ten concurrent CLI sessions. This chapter describes the IPS 4240 and the IPS 4255 and how to install them. It also describes the

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

CROSS Chassis from 160 A to 450 A

CROSS Chassis from 160 A to 450 A CROSS Chassis from 160 A to 450 A STS CATALOGUE Important note! The technical data enclosed is for general information. Please note that the operating instructions and references indicated on the products

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

MODEL KBWD-15 Pulse Width Modulated (PWM)

MODEL KBWD-15 Pulse Width Modulated (PWM) MODEL KBWD-15 Pulse Width Modulated (PWM) DC MOTOR SPEED CONTROL WHISPER DRIVE INSTALLATION AND OPERATING INSTRUCTIONS See Safety Warning on Page 1 and Application Note Warning on Page 2 The information

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Custom "Compact" range with display CD20 Custom Part number

Custom Compact range with display CD20 Custom Part number Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable

More information

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

DSM Dynamic Shunt

DSM Dynamic Shunt DSM Dynamic Shunt 401-30286-00 Installation Manual Part Number 108-31058-00 Giddings & Lewis Controls, Measurement & Sensing NOTE Progress is an on going commitment at Giddings & Lewis. We continually

More information

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing. 1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

200 Watt Passive Shunt Module

200 Watt Passive Shunt Module Installation Instructions 200 Watt Passive Shunt Module (Catalog Number 9101-1183) Drives can require external power dissipation when large inertial loads are present. To ensure that faults due to excessive

More information