Universal signal transducer UKU

Size: px
Start display at page:

Download "Universal signal transducer UKU"

Transcription

1 Universal signal transducer with fully isolated inputs and outputs Universal signal transducer Full isolation between the inputs and outputs Signals can be converted and linearised Adjustable signal level and curve rotation All outputs short-circuit proof Use The universal signal transducer is used for galvanic isolation of various current and voltage signals. These can be converted in the signal transducer and linearised. The signal level and curve rotation can also be adjusted. Functions A V supply Signal structure... V... ma... VPhs V ref ext. X X Electrical isolation Y Y... V... ma V ref ext. V Input side Output side The input signal goes into an A/ converter before passing through an opto-isolator to the output stage. The signal is then processed to give the appropriate voltage ratio as determined by the settings for Y (cut-in) and Y (slope), and finally provided as a filtered analogue output. Electrical isolation Electrical protection In addition to the opto-isolation between signal inputs and outputs, each stage has a fully-isolated electrical supply. All inputs are overvoltage-proof to A V and V. Higher voltages will damage the transducer. The outputs are all short-circuit proof (including the auxiliary supply voltage). There is full isolation between the inputs and outputs and the A V supply. Siemens Building Technologies ANE /. Landis & Staefa ivision /

2 onversion Each universal signal transducer can convert one signal. The options for conversion are as follows:... V phase cut... V... ma into... V or ()... ma into... V or ()... ma into... V or ()... ma Ordering When placing an order, please specify the quantity, product description and type code. Example : universal signal transducer Technical design Adjustment ranges and characteristic curves Reference inputs/outputs The input or output curve setting is determined by an internal reference of. V or an external reference voltage. For an external reference, Switch or Switch should be set to "external". The external reference voltage is connected to Terminals and (Vref. ext.) or Terminals and (Vref. ext.). Examples: For the internal reference voltage: % =. V For the external reference voltage: e.g. % =. V (see connection example ) Signal adaptation Specific signal levels and curve rotations can be achieved to an accuracy of % by adjusting the associated potentiometers and step switches with a suitably sized screwdriver. The relevant scale is the one associated with the connected input or output. Setting the curves Input signal A separate minimum value (X) and maximum value (X) can be set for the input signal. A coarse setting, in steps of %, can be set on potentiometers and. Potentiometers and are used for a fine, linear, adjustment. Output signal A separate minimum value (Y) and maximum value (Y) can be set for the output signal. A coarse setting, in steps of %, can be set on potentiometers and. Potentiometers and are used for a fine, linear, adjustment. Y [ma] Y [V] Y X X Y X [V olt] X [ma] X [V olt] X X Y Y Minimum input signal value Maximum input signal value Minimum output signal value Maximum output signal value Auxiliary supply voltage An auxiliary supply voltage of V is available on the input side, for applications utilising active sensors. (onnection is via Terminals and ). Important : Max. output current = ma! ANE /. Siemens Building Technologies / Landis & Staefa ivision

3 Mechanical design The universal signal transducer consists of a metallic enclosure, accommodating the electronic PB. The facilities for connection and adjustment are located externally for easy access. The connections and adjustment options are as follows: Input side A V V SGN ˆ V ma VPHS SGN ˆ V ma SGN Vref.ext. Vref.ext. SGN AB X Y X Y Y X AB X Y Key : Terminal connections on input side, X, X oarse setting * for input signal characteristic EX / IN External/internal reference voltage switch, X, X Fine setting ** for input signal characteristic, Y, Y Fine setting ** for output signal characteristic, Y, Y oarse setting * for output signal characteristic EX / IN External/internal reference voltage switch Terminal connections on output side AB AB * oarse setting in steps of % ** Fine setting in steps of % Output side Mounting notes The device may be mounted in any orientation. The connection terminals should be freely accessible. The air must be allowed to circulate freely, to dissipate the heat generated during operation. Surface mounting The base incorporates four drilled holes for surface mounting. Rail mounting The base of the housing is designed for snap-mounting on standard IN/EN rails. Rail type: EN- x. Siemens Building Technologies ANE /. Landis & Staefa ivision /

4 Technical data Supply voltage A V,... Hz Max. voltage tolerance ±% Power consumption Max. VA Inputs, SGN... V Input impedance k ohms Max. input voltage V... V phase cut Input impedance k ohms Max. input voltage V phase cut... ma Input impedance ohms Max. input current ma Reference inputs V ref external, SGN Input impedance k ohms Input range.... V V ref external, SGN Input impedance k ohms Input range.... V Output range, SGN... V Min. load resistance > k ohms Max. output voltage V... ma Max. load resistance < ohms Max. output current ma Auxiliary supply V, SGN Voltage tolerance ± % Max. output current ma Accuracy Offset error % Steepness error % Linearity error. % onnections Screw terminals, max. x. mm Protection standard IP to IE Interference immunity IE-/ -/ -/ - Radio interference suppression lass B (to VE, July ) Environmental conditions to IN-IE --/ Ambient temperature of device: Operation... Transport and storage... Weight (incl. packaging). kg imensions (W x H x ) x x mm Housing colour RB onformity Meets the requirements for E marking onnection terminals Input side (top) TE V SGN... V... ma... V Phs SGN Vref.ext. Functional earth Sec. neutral conductor A V Sec. Phase conductor A V Auxiliary supply output Signal ground Input Input Input (phase cut) Signal ground Input for ext. reference voltage Output side (bottom) SGN... V... ma... ma SGN Vref.ext. Signal ground Output Output Output Signal ground Input for ext. reference voltage ANE /. Siemens Building Technologies / Landis & Staefa ivision

5 Application examples Example Examples of connection and settings Input :... V (... %) Output :... ma (... %)... V A V V SGN V ma VPHS SGN Vref.ext. SGN V ma SGN Vref.ext. AB AB X% OUT[%] Y Y X Y% % AB AB X% X IN[%] Y% % Y... ma Y X X Switch settings : X oarse setting : = % Fine setting: = % X oarse setting : A = % Fine setting: = % Y oarse setting : = % Fine setting: = % Y oarse setting : A = % Fine setting: = % EX / IN The internal reference voltage of V is used here. Set switch to Example Input :... V (... %) Output :... ma (... %)... V A V V SGN V ma VPHS SGN Vref.ext.... ma SGN V ma SGN Vref.ext. AB AB % EX. AB AB % X% X% OUT[%] Y Y X X IN[%] Y% Y% Y Y X X Switch settings : X oarse setting : = % Fine setting: = % X oarse setting : A = % Fine setting: = % Y oarse setting : = % Fine setting: = % Y oarse setting : A = % Fine setting: = % EX / IN The internal reference voltage of V is used here. Set switch to Siemens Building Technologies ANE /. Landis & Staefa ivision /

6 Example Input : KLIMO sensor voltage with bridge voltage =. V..... V (... %) Output:.... V (... %) KLIMO A V V SGN V ma VPHS SGN Vref.ext.... V SGN V ma SGN Vref.ext. AB AB % AB AB % X% X% OUT[%] Y Y X X IN[%] Y% Y% Y Y X X Switch settings : X oarse setting : = % Fine setting: = % X oarse setting : = % Fine setting: = % Y oarse setting : A = % Fine setting: = % Y oarse setting : = % Fine setting: = % EX / IN On the input side, the bridge voltage of the klimo controller (Terminals and ) is required as a reference voltage: Set switch to EX / IN On the output side, the internal reference voltage of V is used. Set switch to Example Input :... V phase cut (... %) Output :... V (... %) KLIMO Y AB AB A V V SGN V ma VPHS SGN Vref.ext. X% OUT[%] X% Y SGN V ma SGN Vref.ext. Y Y X Y% AB X IN[%] Y% AB % %... V Y X X Switch settings : X oarse setting : = % Fine setting: = % X oarse setting : A = % Fine setting: = % Y oarse setting : = % Fine setting: = % Y oarse setting : A = % Fine setting: = % EX / IN The internal reference voltage of V is used here. Set switch to Important onnect KLIMO V phase cut output to Terminal of the. onnect KLIMO output signal Y to Terminal (SGN) of the. In this case do NOT use Terminal of the for other applications. The V auxiliary voltage is not available with this application. ANE /. Siemens Building Technologies / Landis & Staefa ivision

7 imensions All dimensions in mm, ø, Siemens Building Technologies ANE /. Landis & Staefa ivision /

8 Siemens Building Technologies Ltd. ANE /. Siemens Building Technologies / Landis & Staefa ivision

Electronic Step Controller

Electronic Step Controller 4 915 Electronic Step Controller, Adjustable switch-on delay (typically used to prevent current surges on startup and after a power failure) Adjustable switch-on points Adjustable switching differential

More information

US2, US4, US6 Electronic step controllers

US2, US4, US6 Electronic step controllers 4 98 US, US4, Electronic step controllers The electronic step controllers are used in linear mode to switch devices (pumps, compressors, humidifiers and fans etc.) on and off in stages. Switch-on time

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

Advantages. Applications

Advantages. Applications 3 s KH 250 General Data Rated input voltage 2 Vac Rated output voltage 2 Vac Rated power 250 VA Ambient temperature +40 C Degree of protection IP 40 Advantages Compensation for mains voltage fluctuations

More information

Differential pressure sensors

Differential pressure sensors 1 912 1912P02 QBM64/ 1912P01 QBM63/ Differential pressure sensors for air and non-aggressive gases, with a diaphragm sensing element QBM63/ QBM64/ With choice of pressure-linear or extracting-the-root

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2 Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity

More information

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display.

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. LCD Display. Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Selectable AC transducer TAS-311DG DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800

More information

VariTrans P D1 TRMS

VariTrans P D1 TRMS Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True

More information

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage. ProLine Interface Technology Loop-Powered Isolators for Standard Signals For isolation of 0(4)... 20 ma standard current signals on up to 3 channels. The Task If no power supply is available, the galvanic

More information

Electronic relays. Monitoring. Monitoring

Electronic relays. Monitoring. Monitoring Electronic relays Neither overload nor underload are particularly good for machines and installations in industrial applications. An unsteady power supply may lead to machine failure and, thus, expensive

More information

Outside Temperature Sensors

Outside Temperature Sensors 1 814 1814P01 Symaro Outside Temperature Sensors QAC31 Active sensors for acquiring the outside temperature Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or 420 ma Use The QAC31 outside

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

Installation- / Monitoring technique

Installation- / Monitoring technique Installation- / Monitoring technique ifferential current monitor IP 5883, Type B for AC and C systems varimeter 0249633 IP 5883 N 5018/035 N 5018/030 According to IEC/EN 62 020, VE 0663 To detect earth

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)

More information

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO Online data sheet WT60-R60 W60 A B C D E F Illustration may differ Ordering information Type Part no. WT60-R60 60097 Other models and accessories www.sick.com/w60 H I J K L M N O P Q R S T Detailed technical

More information

Transducer for Measurement Bridges SCM90, SIGS15

Transducer for Measurement Bridges SCM90, SIGS15 Transducer for Measurement Bridges SCM90, SIGS15 General Description Transducer for measurement bridges for DINrails and for printed circuit boards. Programmable ranges and bridge supply, voltage or current

More information

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C) XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V

More information

Custom "Compact" range with display CD20 Custom Part number

Custom Compact range with display CD20 Custom Part number Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable

More information

XIOC technology and networking modules

XIOC technology and networking modules / XIO XIO digitale and analog input/output modules XIO technology and networking modules XIO the compact I/O and much more XIO are local expansion modules for direct connection to all Xontrol controllers.

More information

J IPC IGBT power converter

J IPC IGBT power converter M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 60 03-0 Fax: +49 661 60 03-6 07 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New) XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

400 (±2,5 V/ V/ ,3% V4A

400 (±2,5 V/ V/ ,3% V4A LVDT Inductive Position Transducer - Hydraulic Series Series Hydraulic position measurement in hydraulic cylinders of machine controls ranges 10...300 mm temperature -40...+150 C (sensors) 0...+60 C (external

More information

Phase and neutral overcurrent protection

Phase and neutral overcurrent protection Phase and neutral overcurrent protection Page 1 ssued June 1999 Changed since July 1998 Data subject to change without notice (SE970165) Features Two-phase or three-phase time-overcurrent and earth fault

More information

Online data sheet WL34-R230 W34 COMPACT PHOTOELECTRIC SENSORS

Online data sheet WL34-R230 W34 COMPACT PHOTOELECTRIC SENSORS Online data sheet WL34-R30 W34 A B C D E F Illustration may differ Ordering information Type Part no. WL34-R30 0949 Other models and accessories www.sick.com/w34 H I J K L M O P Q R S T Detailed technical

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

V P N. Voltage transducer DVM 4200 = 4200 V

V P N. Voltage transducer DVM 4200 = 4200 V Voltage transducer DVM 42 N = 42 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated measurement

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

XUA1 - AC Voltage and phase balance relay

XUA1 - AC Voltage and phase balance relay XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of

More information

5 years! Modular Housings. VariTrans P Warranty

5 years! Modular Housings. VariTrans P Warranty Modular Housings VariTrans P 27000 The Multimeter among the isolators. With 480 switchable calibrated ranges and broad-range power supply. The Task A wide range of measuring signals need to be galvanically

More information

V P N. Voltage transducer DVL 1000 = 1000 V

V P N. Voltage transducer DVL 1000 = 1000 V Voltage transducer DVL 1 V P N = 1 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip

More information

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O echnical data sheet NRF24A-SR-S2(-O) Modulating rotary actuator with emergency function for 2- and 3-way ball valves orque or ue 10 Nm Nominal voltage AC/DC 24 V Control: modulating DC 0... 10 V Position

More information

Analog signal converters CC range

Analog signal converters CC range Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally

More information

Universal Controller

Universal Controller 7 863 Universal Controller POLYGYR RWF32... ISO 9001 RWF32... with casing ARG61.01 The RWF32... is a universal digital boiler temperature / pressure controller designed for use in oil- and / or gas-fired

More information

Moeller Electric Corporation

Moeller Electric Corporation EMR4-I Current Monitoring Relays 02/0053 EMR4-I1-2-A EMR4-I15-2-A EMR4-I15-2-B Mechanical lifespan operations x10 6 30 30 30 24-h cycle, 55 C, 93 % relative humidty, 96 h Ambient temperature min./max.

More information

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI Current Transducer DVL-UI series V PN = 50... 1500 V Unipolar voltage - Current output 4-0 ma Ref: DVL 50-UI, DVL 150-UI, DVL 50-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI For the electronic

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R WLL 0 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC 0... 0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... 0 mm. Proximity systems

More information

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C. ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task

More information

Instruction manual SMART 96-2 / WG-2 ph

Instruction manual SMART 96-2 / WG-2 ph Instruction manual SMART 96-2 / WG-2 ph Stand: 06.09.2015 SMART 96-2 / WG-2 ph / mv Instructions for Installation Configuration PH-mV / Temp. 0...20 ma 4...20mA 20 ma PH-mV / Temp. 0...20 ma 4...20mA 20

More information

LED Driver Constant voltage

LED Driver Constant voltage Driver LCU 100/96W 12/24V IP20 EXC EXCITE indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to

More information

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous

More information

Rotational speed controller

Rotational speed controller Model number Features Rotational speed monitoring up to khz pre-select value with relay output and LED indicator Multi-range power pack -, -, -wire and NAMUR sensors as well as rotary encoder connectable

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

ANALOG SCALING MODULE

ANALOG SCALING MODULE ANALOG SCALING MODULE FEATURES 24V AC operation Output can sink input s pull-up voltage Optional Zero & Span potentiometers Small size 1.10" by 2.19" Two mounting options APPLICATIONS Analog 0 to 5V DC

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated

More information

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force 4 584 ACVATIX Electromotoric actuators for valves SAT.. with a 5.5 mm stroke and 300 N positioning force SAT31.. Operating voltage AC 230 V, 3-position control signal SAT61.. Operating voltage AC/DC 24

More information

Disc Gap Control DGC-2. Technical Manual

Disc Gap Control DGC-2. Technical Manual GB Disc Gap Control DGC-2 Technical Manual Contents Introduction Electronic unit... 1 Tracer valve... 1 Technical data... 2 Component layout... 4 Functions, electronic unit Stepper motor operation...

More information

Electric actuators kn

Electric actuators kn Features Microprocessor controlled with automatic self-calibration on start up LED indication of actuator status Wear-free distance measuring system - no potentiometer Permanent storage of stroke in EPROM

More information

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175, ART-B22-D300 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and

More information

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250 Power Electronics POWERSWITCH Solid-State Contactor, BH 9250 02342 According to IEC/E 60 947-4-2, IEC/E 60 947-4-3 1-, 2- and 3-pole models Load current up to 50 A For AC load up to 480 V Switching at

More information

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Explosion proof rotary actuator - On/Off or programmable regulating actuator Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16 MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A) echnical Data sheets GRK4A-SR-5 Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for butterfly valves and ball valves with mounting flange ISO 511-F05 orque

More information

Instruction manual SMART 96-2 / WG-2 LF

Instruction manual SMART 96-2 / WG-2 LF Instruction manual SMART 96-2 / WG-2 LF Stand: 06.09.2015 SMART 96-2 / WG-2 conductivity Instructions for Installation Configuration ANALOG 2 EC / Temp. 0...20 ma 4...20mA 20 ma ANALOG 1 EC / Temp. 0...20

More information

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Voltage transducer DV 42/SP3 V P N = 42 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4.. Installation instructions Angle position transmitter Type RT-2 Marine bridge instrumentation DEIF A/S Analogue output for direct connection of one or more indicators Measuring output: DC current signal

More information

V P N. Voltage transducer DVM 2000-B = 2000 V

V P N. Voltage transducer DVM 2000-B = 2000 V Voltage transducer DVM 2-B V P N = 2 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions: KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications:

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Room Temperature Controller with Built-in Room Sensor 1 Feb 2002

Room Temperature Controller with Built-in Room Sensor 1 Feb 2002 R, RL C-32-10 Room Temperature Controller with Built-in Room Sensor 1 Feb 2002 R, RL controls room temperature in air handling systems with heating or cooling coils and in VAV systems. The controller has

More information

Current Transducer CTSR 1-P = 1A

Current Transducer CTSR 1-P = 1A Current Transducer CTSR 1-P I PRN = 1A For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary (high power) and the secondary circuit (electronic circuit).

More information

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J Electrical temperature measurement Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J WIKA data sheet TE 91.01 for further approvals

More information

Analog signal converters CC-E I/I

Analog signal converters CC-E I/I 2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New) XU2-AC AC voltage relay (Februar 1997) Manual XU2-AC (Revision New) Woodward Manual XU2-AC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer HO-NSM- SERIES I PN = 8, 15, 25 A Ref: HO 8-NSM-, HO 15-NSM-, HO 25-NSM- For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and

More information

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN Electronic alarm signalling unit TES 20 ENA117.01 EN for temperature and standard signals Universal alarm signalling unit (constructional width 4 T) for Temperature (temperature monitor) with Pt 100 IEC

More information