1 traffic systems and signing TR 2511 Issue A July 2005 Performance Specification for Nearside Signal and Demand Unit Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency

2 (This page intentionally left blank) ii

3 TR 2511 A PERFORMANCE SPECIFICATION FOR NEARSIDE SIGNAL AND DEMAND UNIT CONTENTS Section 1 Introduction 2 Functional Requirements 3 Normative References 4 History Appendix A Informative Guide iii

4 (This page intentionally left blank) iv

5 1 INTRODUCTION 1.1 This specification covers the essential requirements for Nearside Signals and Demand Units for use with signal controlled pedestrian, cycle and equestrian crossings on All-purpose roads. Glossary of Terms 1.9 A comprehensive glossary of terms is given in Highways Agency document TA 84 Code of Practice for Traffic Control and Information Systems for All-Purpose Roads. 1.2 This specification supersedes TR 2181C from the date of issue and the approval process described therein. 1.3 As a statutory requirement, equipment manufactured according to this specification must be approved before its use is permitted on the public highway. 1.4 Statutory Approval (Approval) shall be in accordance with the requirements for Self-Certification set out in TRG Within this specification, The Product shall mean all components necessary to provide a complete operational system meeting the requirements of this specification and the Common Requirements defined in TRG Guidance to potential users of this Product is given in Appendix A. Implementation 1.7 This specification will be immediately implemented from the date of issue for all new approvals. 1.8 Equipment Approvals for this product issued under the previous procedures defined in TRG 0500 will remain valid and no retrospective action will be required providing the build state of that equipment remains unmodified. 1

6 2 FUNCTIONAL REQUIREMENTS General 2.1 This specification defines the requirements for the Puffin, Toucan and Equestrian Nearside Signal and Demand Unit. 2.2 The product allows pedestrians, cyclists and equestrians to register a demand to cross the carriageway, indicate the demand has been registered, and the appropriate period to cross by displaying internally illuminated red and green signals. 2.3 The Product shall function in accordance with this specification when connected to an Approved Traffic Signal controller. Performance 2.4 The requirements of signal intensity for safety of BS 7987 shall be complied with. For signals this is class AF The Product shall comply with the requirements of BS EN The light visible from the Product shall be at full brightness when the input voltage is greater than 75% of the nominal supply voltage. 2.7 The light visible from the Product shall be dimmed (see 2.39) when the input voltage is between 50% and 75% of the nominal supply voltage. 2.8 For signals which are required to be OFF e.g. Green, shall be considered OFF if the voltage on the output of the controller is less than 20% of the full rated output voltage. Physical Requirements 2.9 For Zebra, Pelican and Puffin Pedestrian Crossings, the dimensions and layout of the front of the Product shall be in accordance with The Zebra, Pelican and Puffin Pedestrian Crossings Regulations and General Directions For Toucan and Equestrian crossings, the dimensions and layout of the front of the Product shall be in accordance with The Traffic Signs Regulations and Directions A means of inserting a demand shall be provided. This shall fit into an area of between 225mm 2 and 360mm 2, and be circular, square or rectangular in shape The device in 2.11 shall have an in service life of a minimum of 1x10 6 operations It shall be a design requirement for the device in 2.11, to minimise the risk of jamming by any cause, including foreign objects, moisture or the effects of corrosion An internally illuminated call accepted indicator shall be red and shall be provided around, within or adjacent to the device in The call accepted indicator shall be visible to pedestrians, cyclists and equestrians to show that the demand has been registered. The optical performance of this indicator is detailed in Construction 2.15 The face of the Product shall be impact-resistant in accordance with BS-EN

7 2.16 Means shall be provided for securely fixing the housing to the signal pole. Access to the fixing shall only be available from inside the housing Means shall be provided to permit access to the housing to facilitate the installation and termination of electrical cables and for maintenance purposes Access to the interior of the housing shall be secured by a T key or by other means as agreed with the purchaser The colour of the Product shall be in accordance with the regulations There shall be space available within the base of the Product to incorporate both an audible and tactile device (to TR 2509 and TR 2508 respectively) The product shall be designed such that when correctly fitted, it can be sealed to prevent the ingress of moisture All exposed parts shall be easily replaceable if damaged All internal components shall be capable of being replaced without the need for specialist tools All external corners and edges of the housing, in excess of 40 mm, excepting lower edges, shall be rounded to at least 4 mm radius and all other external edges shall have a radius of at least 1.5 mm The Product s housing located within the signal head, shall be tested to BS EN IP The Product manufactured to this specification shall be designed to have a minimum in-service life of 15 years with suitable maintenance. Electrical Requirements 2.27 The Product shall operate on a voltage no greater than the Extra Low Voltage as defined in BS No voltage in excess of Extra Low Voltage supply shall be permitted in the Product All wiring, termination, earthing and labelling shall be in accordance with BS Optical Performance Requirements 2.30 The Product shall meet the specified limits for the following: i) Luminous Intensity (Refer to 2.31); ii) Luminance Uniformity (refer to 2.34); iii) Chromaticity (refer to 2.37); iv) Sun Phantom Ratio (refer to 2.38). Luminous Intensity Values 2.31 The minimum luminous intensity distribution of the light output from the red and green signals shall be in accordance with the appropriate table. i) Pedestrian signals Table 2.2; ii) Toucan signals Table 2.3; iii) Equestrian signals Table The on-axis luminous intensity value shall not exceed 50 cd The luminous intensity beyond ±60 from the reference axis in the horizontal plane shall be less than 3cd for pictogram figures. 3

8 Luminance Uniformity 2.34 Each Product shall present a uniform appearance, free from excessively bright spots or sectors over the whole area of the signal face when viewed from any angle within the appropriate Product luminous intensity table. Call Accepted Indicator 2.40 The internally illuminated call accepted indicator as described in 2.14 shall have a minimum intensity of 1cd on axis and shall be visible over the distribution range specified in each Product type luminous intensity table when on The light intensity between each point specified within the appropriate Product luminous intensity table and Table 2.1. Chromaticity limits for red and green colours shall be continuous and vary smoothly with each change of angle The red and green pictogram signal Combination shall have a luminance uniformity of 4:1 or better. Luminance measurements shall be taken within a 3 mm diameter circular area, on axis, to within 1 mm of the edges of the entire area of the figure. The ratio of the highest to the lowest reading obtained shall be used to calculate uniformity. Chromaticity 2.37 The chromaticity of the figures shall be within the limits specified in table Table 2.1 when measured on axis at full intensity and when dimmed (refer to Sun Phantom 2.38 Phantom intensity when measured on axis under simulated solar illumination of 40,000 Lux at 10 above the axis shall be greater than 3:1. Dimming Facility 2.39 The Product shall be capable of being dimmed to within the range of 15-25% of full light intensity. When the intensity and remain compliant with the requirements for optical performance. 4

9 Colour x y x y x y x y Red Green Table 2.1 Chromaticity Limits for Red and Green Colours Vertical Horizontal 0 ±10 ± 20 ± Table 2.2 Minimum values of luminous intensity (cd) - Red and Green Pedestrian Figures Vertical Horizontal 0 ±10 ± 15 ± Table 2.3 Minimum values of luminous intensity (cd) - Red and Green Toucan Combinations 5

10 Vertical Horizontal 0 ±10 ± Table 2.4 Minimum values of luminous intensity (cd) - Red and Green Equestrian Figures 6

11 3 NORMATIVE REFERENCES General 3.1 Where undated references are listed, the latest edition of the publication applies. Working Drawings 3.2 Working Drawings are available from: Department for Transport Great Minster House 76 Marsham Street LONDON SW1P 4DR Bicycle Drawing No: S24. Green Man Drawing No: P of 3 Horse and Mount Drawing No: S8 Red Man Drawing No: P of 3 British Standards 3.3 British Standards are published by the British Standards Institution, London. Contact: +44 (0) BS 7671 Requirements for Electrical Installations BS EN Traffic Signals BS EN Degrees of protection provided by enclosures for electrical equipment against mechanical impacts (IP code). BS EN Electromagnetic Compatibility Road Traffic Signal Systems Product Standard BS EN Safety of Laser Products Specifications 3.4 Specifications are published by the Highways Agency. Contact: +44 (0) tss_plans_registry@highways.gsi.gov.uk. WEB address: TR 2130 TR 2508 Environmental Tests for Motorway Communications Equipment and Portable and Permanent Traffic Control Equipment Performance Specification for Tactile equipment 7

12 TR 2509 TR 2523 TRG 0600 Performance Specification for Audible Unit for use at Pedestrian Crossings Traffic Signal Equipment Interface Specification Self-Certification and Approval of Equipments for the Control of Vehicular and Pedestrian Traffic on Roads Other Publications TSRGD ZPPRGD The Traffic Signs Regulations and General Directions The Zebra, Pelican and Puffin Pedestrian Crossings Regulations and General Directions.. 8

13 4 HISTORY TR 2181 Issue C July 2001 TR 2511 Issue A July 2005 Approval of this document for publication is given by the undersigned Traffic Signals and Road Lighting Safety Zone 2/17E Temple Quay House 2 The Square Temple Quay Bristol BS1 6HA Mike Smith Team Manager Traffic Signals and Road Lighting Safety 9

14 APPENDIX A INFORMATIVE GUIDE General A1 A2 This Appendix is an informative guide to Systems Integrators and Highways Authorities who wish to purchase / hirer and use Nearside units for use at Pedestrian, Toucan or equestrian Crossings, that has been declared conformant to this specification. Prospective purchasers/hirers should ensure that the procurement contract address the following issues. The Procurement Contract should ensure that the enclosure housing the Product s electronic circuitry is constructed of materials that will withstand the rigours of the environment in which it is intended to operate. Connections A3 The Procurement Contract should ensure that all connections to the Product are such, that the unit can be easily removed from its installed position by an authorised maintenance staff. Marking and Labelling A4 The Procurement Contract should ensure that all connections have be clearly identified and that the Product displays a label showing the Following: i) The unique product identity number and serial number; ii) iii) The HA Specification and associated Appendix against which it has been declared compliant; The electrical supply requirements of the Product. A1

Performance Specification For Tactile Equipment for use at Pedestrian Crossings

Performance Specification For Tactile Equipment for use at Pedestrian Crossings traffic systems and signing TR 2508 Issue A July 2005 Performance Specification For Tactile Equipment for use at Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency (This

More information

Performance Specification for Light Signals for the Control of Tramcars

Performance Specification for Light Signals for the Control of Tramcars traffic systems and signing TR 2514 Issue A Sept 2005 Performance Specification for Light Signals for the Control of Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency

More information

Siemens ST950 & ST900 Statement of Compliance Against TR 2513 Issue A, September 2005 Performance Specification for Wig Wag Signal Control Equipment

Siemens ST950 & ST900 Statement of Compliance Against TR 2513 Issue A, September 2005 Performance Specification for Wig Wag Signal Control Equipment Mobility and Logistics Traffic Solutions Sopers Lane Poole, Dorset BH17 7ER SYSTEM/PROJECT/PRODUCT: Traffic Controllers Siemens ST950 & ST900 Statement of Against TR 2513 Issue A, September 2005 Performance

More information

Performance Specification for Below Ground Vehicle Detection Equipment

Performance Specification for Below Ground Vehicle Detection Equipment traffic systems and signing TR 2512 Issue A Sept 2005 Performance Specification for Below Ground Vehicle Detection Crown Copyright 2005 First published 2005 Printed and published by the Highways Agency

More information

Distribution transformers Part 2 Ground mounted transformers not closecoupled

Distribution transformers Part 2 Ground mounted transformers not closecoupled PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Technical Specification 35-1 Distribution transformers Part 2 Ground mounted transformers not closecoupled www.energynetworks.org PUBLISHING

More information

TOPAS 2500A Specification for Traffic Signal Controller

TOPAS 2500A Specification for Traffic Signal Controller Revision Date Scope Authorised by A (v1) 09/01/15 Draft Admin A (v2) 19/0/15 Draft Admin A (v) A (v4) 17/04/15 11/0/16 Final Final Board Board Traffic Open Products And Specifications Limited 2014. This

More information

Transport Canada Standard for LED Signal Modules at Highway/Railway Grade Crossings. TC E-14 (October 10, 2003)

Transport Canada Standard for LED Signal Modules at Highway/Railway Grade Crossings. TC E-14 (October 10, 2003) Transport Canada Standard for LED Signal Modules at Highway/Railway Grade Crossings TC E-14 (October 10, 2003) - 2 - PURPOSE The purpose of this standard is to provide the minimum performance requirements

More information

TS RES - OUTSTANDING ISSUES

TS RES - OUTSTANDING ISSUES TS RES - OUTSTANDING ISSUES This document has been officially issued as DRAFT until the following outstanding issues have been resolved. At that time the document will be officially reissued as the next

More information

Steel wire for general fencing purposes

Steel wire for general fencing purposes BRITISH STANDARD BS 4102:1998 ICS 77.140.65 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Specification for Steel wire for general fencing purposes Committees responsible for this

More information

Standard for LED Signal Modules at Highway-Railway Grade Crossings

Standard for LED Signal Modules at Highway-Railway Grade Crossings Standard for LED Signal Modules at Highway-Railway Grade Crossings October 10, 2003 TM Standard For LED Signal Modules At Highway/Railway Grade Crossings Effective : October 10, 2003 CONTENT 1. PURPOSE

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-28950-8 Any reference to SABS 098-1 is deemed to be a reference to this standard (Government Notice No. 1373 of 8 November 2002) SOUTH AFRICAN NATIONAL STANDARD Public lighting Part 1: The

More information

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: info@ftmsrl.it

More information

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents- SECTION 30 LIGHTING STANDARDS -Section Contents- 3001 Intent... 30-2 3002 Applicability... 30-2 3003 Exceptions... 30-2 3004 Prohibited Lighting... 30-2 3005 General Requirements... 30-3 3006 Sign Lighting...

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount.   EPA Rating 2.33ft 2. Cat# 71896 380W FlatPanel Pole Mount Model: 71896 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure

More information

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS

EDS LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS ENGINEERING DESIGN STANDARD EDS 08-2109 LV SUPPLIES TO MOBILE PHONE BASE STATIONS MOUNTED ON TRANSMISSION TOWERS Network(s): Summary: EPN, LPN, SPN This standard provides guidance on the installation of

More information

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines July 23, 2004 U N I T E D S T A T E S A C C E S S B O A R D A FEDERAL AGENCY COMMITTED TO ACCESSIBLE DESIGN TECHNICAL

More information

MUNICIPAL OUTDOOR LIGHTING STANDARDS FOR THE CONTROL OF LIGHT POLLUTION

MUNICIPAL OUTDOOR LIGHTING STANDARDS FOR THE CONTROL OF LIGHT POLLUTION THE CORPORATION OF THE DISTRICT OF SAANICH MUNICIPAL OUTDOOR LIGHTING STANDARDS FOR THE CONTROL OF LIGHT POLLUTION SCHEDULE A to Sign Bylaw No. 8789 Page 17 of 23 MUNICIPAL OUTDOOR LIGHTING STANDARDS FOR

More information

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT THE KENYA POWER AND LIGHTING CO. LTD SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT NAME DESIGNATION SIGNATURE DATE Compiled by Ephantus Nyagah Ag. Senior Engineer Checked by Eng. Thagichu Kiiru Deputy

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71402 LED High Bay QPL ID # PPXEAWS8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: 71402 Input Voltage 100-277VAC 50/60HZ Input Current 1.2A Max Input Power 100 W

More information

PHOTOELECTRIC SENSORS. Online data sheet

PHOTOELECTRIC SENSORS. Online data sheet Online data sheet A B C D E F Illustration may differ Ordering information Type Part no. WTB4SL-3P6V 0585 Other models and accessories www.sick.com/w4sl-3v H I J K L M N O P R S T Detailed technical data

More information

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A 71345A 50W LED Floodlight Yoke(Bracket) Mount RoHS QPL ID # PLDUWHES4P5Q Model: Input Voltage Input Current Input Power Power Factor OVERALL LAMP Luminance PARAMETERS Luminous Efficiency CRI Beam Angle

More information

Cat# 71146A 150W Trunion Mount

Cat# 71146A 150W Trunion Mount Cat# 71146A 150W Trunion Mount RoHS Dimming: 0-10V/PWM/VR QPL ID # PLZOBKAFGDBR Model: 71146A Input Voltage 120-277 VAC 50/60HZ Input Current 1.7A MAX Input Power 150W Power Factor PF 0.90 OVERALL LAMP

More information

71352A QPL ID # PLT2P2L2UNWR. RoHS

71352A QPL ID # PLT2P2L2UNWR. RoHS Dimming: 0-10V/PWM/VR 71352A 80W LED Floodlight Trunnion Mount Model: RoHS 71352A QPL ID # PLT2P2L2UNWR Input Voltage 100-277AC 50/60HZ Input Current 1.00A MAX Input Power 80 W Power Factor PF 0.90 OVERALL

More information

RED Compliance Association REDCA TGN 01 Version 1.0 November 2018 Page 1 of 14

RED Compliance Association REDCA TGN 01 Version 1.0 November 2018 Page 1 of 14 November 2018 Page 1 of 14 REDCA Technical Guidance Note 01 on the RED compliance requirements for a Radio Equipment often referred to as Radio Module and the Final Radio Equipment Product that integrates

More information

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LED Floodlight. RoHS. Model: inner box: L 17 X W 12.5 X H 9.33 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W. 71352 LED Floodlight RoHS Model: 71352 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage

More information

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------

More information

Installation & Operating Manual. iwap202

Installation & Operating Manual. iwap202 Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and

More information

Work Type Definition and Submittal Requirements Work Type: Subsurface Utility Engineering (SUE)

Work Type Definition and Submittal Requirements Work Type: Subsurface Utility Engineering (SUE) MUST be qualified under Minnesota Department of Transportation Prequalification Program - Work Type 15.1 Subsurface Utility Engineering The first section, Work Type Definition, provides a detailed explanation

More information

ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3

ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3 ELECTRIAL AND SIGNING MATERIALS STANDARDS VOLUME 3 Electrical and ITS Engineering September 2018 2300 ELECTRONIC MESSAGE SIGNS 2301 PERMANENT ELECTRONIC MESSAGE SIGNS 2302 PORTABLE ELECTRONIC MESSAGE SIGNS

More information

SPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit

SPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit 1993 Specifications SPECIAL SPECIFICATION 1201 12 Inch LED Traffic Signal Lamp Unit 1. Description. This specification describes the minimum acceptable design and performance requirements for a twelve

More information

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2 City of Los Angeles Plan Check No. 1. Except building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos, new or altered signs

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011 NATIONAL RULES FOR ELECTRICAL INSTALLATIONS Fourth Edition ET 101:2008 Extracts from Amendment No.1:2011 22 June 2011 Page vi: Insert after 1 st Paragraph: Section 710: Medical Locations was prepared by

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-21567-5 SOUTH AFRICAN NATIONAL STANDARD Lights for motor vehicles Part 1: Incandescent lamps Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001

More information

Suppliers' Information Note. BT Metallic Path Facility. Interface Description

Suppliers' Information Note. BT Metallic Path Facility. Interface Description SIN 349 Issue 2.5 August 2015 Suppliers' Information Note For The BT Network BT Metallic Path Facility Interface Description Each SIN is the copyright of British Telecommunications plc. Reproduction of

More information

Technical recommendation for the purchase of Real Time Thermal Rating for transformers

Technical recommendation for the purchase of Real Time Thermal Rating for transformers Version: 1.0 Date of Issue: December 2014 1 Technical recommendation for the purchase of Real Time Thermal Rating for transformers 1 Purpose The purpose of this document is to set out and describe the

More information

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY TT403- K (1000W) Wireless Inline Switch Product Description The TT403- K is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does

More information

www.greenelectricalsupply.com P 0 0 0 Cat# 71574A 100 Watts Pole Mount RoHS QPL ID # PLV5YTKQ0SQJ OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous

More information

Scheduling, dimensioning, bending and cutting of steel reinforcement for concrete Specification

Scheduling, dimensioning, bending and cutting of steel reinforcement for concrete Specification BRITISH STANDARD BS 8666:2005 Incorporating Amendment No. 1 Scheduling, dimensioning, bending and cutting of steel reinforcement for concrete Specification ICS 77.140.15; 91:080.40 Committees responsible

More information

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Dimming: PWM/TIME/0-5V/0-10V. RoHS Dimming: PWM/TIME/0-5V/0-10V Cat# 71575A 150 Watts Pole Mount RoHS QPL ID # PLMWEKHWJOBH Model: 71575A OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance

More information

SECTION SIGNAGE

SECTION SIGNAGE SECTION 10 14 00 SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section, apply

More information

E/ECE/324/Rev.1/Add.86/Rev.3/Amend.1 E/ECE/TRANS/505/Rev.1/Add.86/Rev.3/Amend.1

E/ECE/324/Rev.1/Add.86/Rev.3/Amend.1 E/ECE/TRANS/505/Rev.1/Add.86/Rev.3/Amend.1 27 November 2013 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions

More information

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90 Cat# 71554 30 Watts 1/2" Knuckle Mount RoHS QPL ID # PHNRJ3EY Model: 71554 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI

More information

CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES

CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES I. PURPOSE AND COMPLIANCE In implementing City Code, Chapter 8, Section 815, the City Council of the City of Pine City (the City ) finds that

More information

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS Cat# 71543 150 Watts Trunion Mount RoHS QPL ID # PF9T16AA Model: 71543 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam

More information

RoHS QPL ID # PLC6V1PABNUJS

RoHS QPL ID # PLC6V1PABNUJS Cat# 71836 220 Watts Trunion Mount RoHS QPL ID # PLC6V1PABNUJS OVERALL LAMP PARAMETERS LED DRIVER LED Input Power Power Factor Luminance Luminous Efficiency CRI R9 8 Beam Angle Main Structure Output Voltage

More information

Cat# LED Wall-PACK

Cat# LED Wall-PACK Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle

More information

PRACTICE NOTE NO: 13 Version 1 Amended March 2001 Page 1 of 6 PRECAST CONCRETE ELEMENT DESIGN RESPONSIBILITIES AND CONTRACTUAL ARRANGEMENTS

PRACTICE NOTE NO: 13 Version 1 Amended March 2001 Page 1 of 6 PRECAST CONCRETE ELEMENT DESIGN RESPONSIBILITIES AND CONTRACTUAL ARRANGEMENTS PRACTICE NOTE NO: 13 Version 1 Amended March 2001 Page 1 of 6 Scope This Practice Note is intended to identify responsibilities and contractual arrangements for precast elements used in buildings. Such

More information

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS. Model: VAC 50/60HZ.83A Max 100W Cat# 71542 100 Watts Trunion Mount RoHS UL/CUL TUV-CE QPL ID # PTX2Q1C3 Model: 71542 Input Voltage Input Current Input Power 100-277VAC 50/60HZ.83A Max 100W OVERALL LAMP PARAMETERS LED DRIVER LED Power

More information

CITY OF KENT, OHIO ZONING CODE APPENDIX B SIGN DESIGN GUIDELINES APP B - 1 ZONING CODE APPENDIX B SIGN DESIGN GUIDELINES

CITY OF KENT, OHIO ZONING CODE APPENDIX B SIGN DESIGN GUIDELINES APP B - 1 ZONING CODE APPENDIX B SIGN DESIGN GUIDELINES APPENDIX B SIGN DESIGN GUIDELINES APP B - 1 ZONING CODE APPENDIX B SIGN DESIGN GUIDELINES Purpose and Applicability The purpose of the Sign Design Guidelines is to provide design criteria to be utilized

More information

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department SOUTH DUBLIN COUNTY COUNCIL Roads (Traffic and Transportation) Department TECHNICAL SPECIFICATION 2 SDCC-TS-02 INDUCTIVE LOOPS & ABOVE GROUND DETECTION REQUIREMENTS FOR THE DESIGN AND INSTALLATION OF TRAFFIC

More information

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB Cat# 71541 80 Watts Trunion Mount RoHS QPL ID # PNZ72BAB OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure

More information

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB Cat# 71561 80 Watts Slipfitter Mount Model: 71561 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Equipment Set for Wave Optics with Laser 1003053 Instruction sheet 06/18 Alf 1. Safety instructions The laser emits visible radiation at a wavelength of 635 nm with a maximum power

More information

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0. LED Wall-PACK/Flood Light Data Sheet Cat# 71152 Direct to wall RoHS Wet Locations Use QPL ID # PLUV5PQHJX3Z Model: 71152 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Input Voltage

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance MEDIUM VOLTAGE PRODUCT KOKM Cable current instrument transformers Instruction for Installation, use and maintenance 2 KOKM CABLE CURRENT INSTRUMENT TRANSFORMERS INSTRUCTION FOR INSTALLATION, USE AND MAINTENANCE

More information

Dust Test Surface Cleanliness

Dust Test Surface Cleanliness Paint Test Equipment Dust Test Surface Cleanliness Dust Test Information ISO 8502-3: Preparation of steel substrates before application of paints and related products. Tests for the assessment of surface

More information

4 Channel Frequency Conscious Noise Gate. Operation Manual

4 Channel Frequency Conscious Noise Gate. Operation Manual 4 Channel Frequency Conscious Noise Gate Operation Manual June 2005 This page has been left intentionally blank for your notes Page 2 CONTENTS 1.0 OVERVIEW 4 2.0 DESCRIPTION OF CONTROLS 5-7 2.1 Bypass

More information

Cat# 71440A LED Classic Large Wall-Pack

Cat# 71440A LED Classic Large Wall-Pack Cat# 71440A LED Classic Large Wall-Pack Dimming: 0-10V/PWM/VR QPL ID # PL8EA2B65DY8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power

More information

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T** Assembly Instructions for: PL ** Series Junction Boxes IMPORTANT: This document should be read carefully before commencing installation Zones of Use for Box - as defined in IEC/EN 00-0 and IEC/EN 00--1

More information

For use in Flammable Gas and Dust Atmospheres

For use in Flammable Gas and Dust Atmospheres ISTRUCTIO MAUA (ATEX) BExCBG0505D Flameproof Combined / For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExCBG0505D is a second generation flameproof combined beacon / beacon which is

More information

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69 Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI

More information

E/ECE/324/Rev.1/Add.47/Rev.6/Amend.1 E/ECE/TRANS/505/Rev.1/Add.47/Rev.6/Amend.1

E/ECE/324/Rev.1/Add.47/Rev.6/Amend.1 E/ECE/TRANS/505/Rev.1/Add.47/Rev.6/Amend.1 4 October 2010 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions for

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Equipment Set for Wave Optics with Laser U17303 Instruction sheet 10/08 Alf 1. Safety instructions The laser emits visible radiation at a wavelength of 635 nm with a maximum power

More information

Dust Test Data Sheet / Instructions

Dust Test Data Sheet / Instructions Paint Test Equipment Dust Test Data Sheet / Instructions Dust Test Information ISO 8502-3: Preparation of steel substrates before application of paints and related products. Tests for the assessment of

More information

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title Substation Auxiliary Transformer from Rectifier Transformer Secondary Reference Number PDS 01 (RIC Standard: EP 05 00 00 01 SP) Document Control

More information

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER Approval Amendment Record Approval Date Version Description 03/05/2017 1 Initial issue PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 13 Table of Contents 1. Purpose...

More information

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens Cat# 71552 15 Watt 1/2" Adjustable Knuckle Mount RoHS QPL ID # P4K7RKA9 Model: 71552 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016 STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE January 15, 2016 919.01 Traffic Signal Cabinet and Controller Unit General Requirements 919.02 Approved

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T** Assembly Instructions for: PL ** Series Junction Boxes AI 23 / Issue W - 01/ IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Box CAT II 2G for use in Zone

More information

TT W Wireless receiver Inline Switch

TT W Wireless receiver Inline Switch TT403 1000W Wireless receiver Inline Switch Product Description The TT403 is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does

More information

Chapter 24 Outdoor Lighting Ordinance

Chapter 24 Outdoor Lighting Ordinance Chapter 24 Outdoor Lighting Ordinance Section 10:24:1 Section 10:24:2 Section 10:24:3 Section 10:24:4 Section 10:24:5 Section 10:24:6 Section 10:24:7 Section 10:24:8 Purpose Scope and Applicability Conformances

More information

CrystalWay Emergency lighting luminaires Product Brochure. Safety with total transparency

CrystalWay Emergency lighting luminaires Product Brochure. Safety with total transparency CrystalWay Emergency lighting luminaires Product Brochure Safety with total transparency CrystalWay Safety with total transparency CrystalWay is a new range of self-contained units and aesthetic evacuation

More information

CLARK COUNTY FIRE CODE AMENDMENTS

CLARK COUNTY FIRE CODE AMENDMENTS CLARK COUNTY FIRE CODE AMENDMENTS SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE SYSTEM is amended to read as follows: SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE SYSTEM 510.1 Emergency responder radio

More information

Economic and Social Council

Economic and Social Council UNITED NATIONS E Economic and Social Council Distr. GENERAL 25 July 2005 Original: ENGLISH ENGLISH AND FRENCH ONLY ECONOMIC COMMISSION FOR EUROPE INLAND TRANSPORT COMMITTEE World Forum for Harmonization

More information

Review of Folded Self Mailer (FSM) DMM Standards

Review of Folded Self Mailer (FSM) DMM Standards Review of Folded Self Mailer (FSM) DMM Standards (Effective January 5, 2013) Module 1: Basics for the Host Piece Module Objectives At the end of this module you will be able to: Understand the definition

More information

Automatic Film Applicator BEVS 1811/2 User Manual

Automatic Film Applicator BEVS 1811/2 User Manual Automatic Film Applicator BEVS 1811/2 User Manual This manual shall be read carefully before starting. Directions included in this operation manual shall be strictly followed. PAGE 1 Content 1 Company

More information

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount.  Model: master carton: L*W*Hmm 1PCS. EPA Rating 1. Cat# 71544 220 Watts Trunion Mount Model: 71544 RoHS QPL ID # P9JSE2P8 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam

More information

Illumine & RAILled illumination for metal handrails

Illumine & RAILled illumination for metal handrails Illumine & RAILled illumination for metal handrails The advantages of handrail illumination with SG Systems Performance lighting & Energy efficiency Our Illumine and RAILled products are designed to provide

More information

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 10441 (10 14 00) SIGNAGE A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section,

More information

Identification and recording of 'hot' sites - joint procedure for Electricity Industry and Communications Network Providers

Identification and recording of 'hot' sites - joint procedure for Electricity Industry and Communications Network Providers PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Engineering Recommendation S36 Identification and recording of 'hot' sites - joint procedure for Electricity Industry and Communications

More information

Road signs Specifications

Road signs Specifications AS 1743:2018 AS 1743:2018 Road signs Specifications This Australian Standard was prepared by Committee MS-012, Road Signs and Traffic Signals. It was approved on behalf of the Council of Standards Australia

More information

Temporary Sign Permit

Temporary Sign Permit 36725 Division Road, P.O. Box 457, Richmond, MI 48062 Building and Planning Department 586-727-7571 ext. 228 586-727-2489 Fax Temporary Sign Permit Application and Regulations Page 1 Updated: 15OCT15 Temporary

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61935-1 Edition 3.0 2009-07 Specification for the testing of balanced and coaxial information technology cabling Part 1: Installed balanced cabling as specified in ISO/IEC 11801

More information

Guide to the LEDiL 2X2 lens modules

Guide to the LEDiL 2X2 lens modules 450 160 750 240 320 105 105 90 90 75 75 60 60 1 0 45 45 2 1 0 1 30 15 0 15 30 450 450 750 750 C0 - C180 C90 - C270 100 150 450 1 Guide to the LEDiL 2X2 lens modules 450 160 750 240 320 105 105 90 90 75

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION NMF01:2018 Edition 1.0 1.6.2018 NMF Nordic cooperation group in the field of road equipment NMF Nordiskt Möte för Förbättrad vägutrustning Contents Contents... 2 Foreword... 3 Introduction...

More information

CITY of ALBUQUERQUE SIXTEENTH COUNCIL

CITY of ALBUQUERQUE SIXTEENTH COUNCIL CITY of ALBUQUERQUE SIXTEENTH COUNCIL COUNCIL BILL NO. ENACTMENT NO. SPONSORED BY: [+Bracketed/Underscored Material+] - New [-Bracketed/Strikethrough Material-] - Deletion ORDINANCE CITY OF ALBUQUERQUE

More information

TECHNICAL SHEET. Outdoor architectural projector RONDO-01 9LED. About the product. RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome

TECHNICAL SHEET. Outdoor architectural projector RONDO-01 9LED. About the product. RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome No. 352 / 02.12.2014, Edition No. 9, 1/5 Outdoor architectural projector RONDO-01 9LED RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome About the product The RONDO-01 LED projector is designed for architectural

More information

CONSOLIDATED VERSION IEC TR Code of practice for hearing-loop systems (HLS) colour inside. Edition

CONSOLIDATED VERSION IEC TR Code of practice for hearing-loop systems (HLS) colour inside. Edition CONSOLIDATED VERSION IEC TR 63079 Edition 1.1 2018-09 colour inside Code of practice for hearing-loop systems (HLS) INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 17.140.50 ISBN 978-2-8322-6041-8 Warning!

More information

GB-DAS. Installation and user manual Devireg 850 sensor

GB-DAS. Installation and user manual Devireg 850 sensor GB-DAS Installation and user manual Devireg 850 sensor 1 Table of content 1 Sensors and control zones 3 1.1 Sensor types and function 3 1.2 Control zones 4 1.3 Assign sensors to control zones 5 2 Placing

More information

www.greenelectricalsupply.com Cat# 71855 220 Watts Pole Mount RoHS UL/CUL TUV-CE QPL ID # PLTP6C Q97 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance

More information

JED Specification

JED Specification JED Specification 2008-08 Class: Engineering guidelines Class No.:07 Marking of WABCO products JED 341 Previous Edition Abbreviated Title 1988-12 Marking of WABCO products 852 003 410 4 1 Scope...3 2 Types

More information

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance PRODUCT FOR HIGH VOLTAGE APPLICATION Current transformers for Gasinsulated switchgear type ELK Instructions for installation, use and maintenance 2 CURRENT TRANSFORMERS FOR GAS-INSULATED SWITCHGEAR TYPE

More information

USER S MANUAL. Rail-mounted temperature transmitter ATL

USER S MANUAL. Rail-mounted temperature transmitter ATL IO.ATL (ENG) USER S MANUAL Rail-mounted temperature transmitter ATL APLISENS S.A., 03-192 Warszawa, ul. Morelowa 7 tel. +48 22 814 07 77; fax +48 22 814 07 78 www.aplisens.pl, e-mail: aplisens@aplisens.pl

More information

Yagi and Omni Antennas Installation Manual

Yagi and Omni Antennas Installation Manual Yagi and Omni Antennas Installation Manual 25500445 Rev. A0 0218 Printed in U.S.A. Copyright 2018 Federal Signal Corporation Limited Warranty This product is subject to and covered by a limited warranty,

More information

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions Edgerail System Specification & Installation Instructions Hill & Smith, Inc 1000 Buckeye Park Road Columbus, Ohio 43207 Tel: 614-340-6294 Fax: 614-340-6296 www.hillandsmith.com Section A System Specification

More information

Absolute Block. Uncontrolled When Printed Document to be part superseded by GKRT0055 Iss 1 and GKRT0077 Iss 1 (published on 07/09/2013)

Absolute Block. Uncontrolled When Printed Document to be part superseded by GKRT0055 Iss 1 and GKRT0077 Iss 1 (published on 07/09/2013) Signatures removed from electronic version Submitted by... Richard Genner Nominated Responsible Manager Approved by... Philip Wiltshire Chairman, Train Control & Communications Subject Committee Approved

More information

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2

More information

Powerlink Plus Technical

Powerlink Plus Technical CABLE MANAGEMENT mkelectric.co.uk TECHNICAL SPECIFICATION ELECTRICAL VOLTAGE RATING 63A, 250V a.c. VOLTAGE DROP L to N = 3.47 mv/a/metre run L to E = 3.47 mv/a/metre run N to E = 3.47 mv/a/metre run EARTH

More information