Status of the BIPM Watt Balance

Size: px
Start display at page:

Download "Status of the BIPM Watt Balance"

Transcription

1 Status of the BIPM Watt Balance H. Fang, M. Stock

2 Present apparatus in the new laboratory New force comparator, vacuum compatible Laser source for interferometers New weighing pan New mass lifting device Modifications made to accommodate the apparatus Also some new components Fully operational in air

3 New components for the watt balance In-situ calibration of weighing cell Mass exchanger most mechanical parts available to be integrated into suspension Dynamic alignment system New magnet vacuum: < 0,01 Pa ready for measurements in 2014 no air convection; no air buoyancy no air refractive index correction 3

4 Fabrication planning for the new magnet Last step: assembly

5 New magnet: fabrication of parts Inner cover Outer cover Sm 2 Co 17 magnets Housing Core All parts now at BIPM All components meet the specifications Trial assembly (without the magnets) and uniformity of the gap width verified ( <1 µm)

6 New magnet: verification (assembly without magnets) measurement direction 2 capacitive sensors in opposition

7 New magnet: verification profile at 30 1 µm up down up profile at 60 up down up 1 µm

8 New magnet: assembly nearly finished magnetic force 1000 force / N distance / mm Some problems with too tight tolerances: now solved

9 Sources of the surrounding vibration noise (1) Air conditioners OFF Air conditioners successively ON Three noisiest units identified To be replaced or removed by October 2013

10 Sources of the surrounding vibration noise Red: air conditioners ON Hz Blue: air conditioners OFF 18 Hz Hz 34 Hz 65 Hz

11 Periodical non-linearity error (1) ϕ Laser f 1 f 2 f = 20 MHz Heterodyne interferometer PBS λ/4 f 2 Polarizer λ/4 f 1 l φ = 4π l /λ 2 λ/2 Extra phase term: periodic deviations (optical quality & alignment)

12 Periodical non-linearity error (2) 1 st order non-linearity Doppler frequency of about 600 Hz Significant 2 nd order non-linearity Example of the observed non-linearity errors (sampling rate of 25 khz) 6 nm 1 st axis 2 nd axis 10 nm short term: - better alignment - mathematical reduction long term: - new interferometer (2014) with physical separation of beams 6 nm 3 rd axis

13 Reduction by mathematical methods polynomial fitting position to be measured averaging Various methods evaluated Two of them (averaging and polynomial fitting) used Gave similar results in the present measurement conditions Averaging method Relative std. dev. (averaging method): 1 pt 2.8 x periods 7.6 x periods 9.3 x periods 3.2 x 10-4

14 Voltage-to-velocity ratio voltage-to-velocity ratio σ = 2 x 10-4 (normal coil U/v = 500 V.s/m) U = BL v U ( z) (1 + ε ( z)) N v ( z) (1 + ε ( z)) N Further reduction norm.voltage/velocity single up measurement σ = 8 x 10-5 (bifilar coil U/v = 250 V.s/m) norm.voltage/velocity 28 Hz peak -> stiffer coil (Macor) residual non-linearity error -> new interferometer vibration noise -> investigation under way phase resolution -> better phase detection Position in air gap / mm..etc.

15 Force measurement black: old location red: new location F ( N z) (1 + ε ( z)) I ( z) 20 mg 2 x 10-4 (100 g test mass) acceleration (vibration) single up measurement raw force 20 mg corrected force σ = 3 x 10-5

16 Next steps - assembly of the new magnet done - integration of new measurement facilities - vibration reduction (repl. of air cond.) - new stiffer coil done - new alignment reference - nexth measurements spring new interferometer (2014)

17 BIPM watt balance team Full-time Part-time Hao Fang principal physicist Adrien Kiss engineer Thomas Lavergne engineer (mechanics, since May 2013 for 2 years) Michael Stock (project leader; magnet) Lennart Robertsson (interferometry) Estefania de Mirandés (coil alignment, gravimetry) Stéphane Solve (JVS) Régis Charamy (JVS)

18

This is how PI Does Measuring - Part I

This is how PI Does Measuring - Part I WHITEPAPER This is how PI Does Measuring - Part I This is how PI Does Measuring - Part I Measuring Environment / Measuring Equipment Portfolio / Data Evaluation Physik Instrumente (PI) GmbH & Co. KG, Auf

More information

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry The Lecture Contains: Laser Doppler Vibrometry Basics of Laser Doppler Vibrometry Components of the LDV system Working with the LDV system file:///d /neha%20backup%20courses%2019-09-2011/structural_health/lecture36/36_1.html

More information

SPRAY DROPLET SIZE MEASUREMENT

SPRAY DROPLET SIZE MEASUREMENT SPRAY DROPLET SIZE MEASUREMENT In this study, the PDA was used to characterize diesel and different blends of palm biofuel spray. The PDA is state of the art apparatus that needs no calibration. It is

More information

AC Circuit. What is alternating current? What is an AC circuit?

AC Circuit. What is alternating current? What is an AC circuit? Chapter 21 Alternating Current Circuits and Electromagnetic Waves 1. Alternating Current 2. Resistor in an AC circuit 3. Capacitor in an AC circuit 4. Inductor in an AC circuit 5. RLC series circuit 6.

More information

Development of the accelerometer for cryogenic experiments II

Development of the accelerometer for cryogenic experiments II Development of the accelerometer for cryogenic experiments II ICRR Univ. of Tokyo, KEK A, Dept. of advanced materials science Univ. of Tokyo B K. Yamamoto, H. Hayakawa, T. Uchiyama, S. Miyoki, H. Ishitsuka,

More information

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications Carlos Macià-Sanahuja and Horacio Lamela-Rivera Optoelectronics and Laser Technology group, Universidad

More information

Vibration measurement in the cryogenic interferometric gravitational wave detector (CLIO interferometer)

Vibration measurement in the cryogenic interferometric gravitational wave detector (CLIO interferometer) Vibration measurement in the cryogenic interferometric gravitational wave detector (CLIO interferometer) ICRR Univ. of Tokyo, Dept. of geophysics Kyoto University A, KEK B, Dept. of advanced materials

More information

TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS

TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS IWAA2004, CERN, Geneva, 4-7 October 2004 TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS Andreas Herty, Hélène Mainaud-Durand, Antonio Marin CERN, TS/SU/MTI, 1211 Geneva 23, Switzerland 1. ABSTRACT

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration, Inc. 1 Industrial

More information

Microscopic Laser Doppler Vibrometer

Microscopic Laser Doppler Vibrometer Microscopic Laser Doppler Vibrometer System Configuration - 1 PC Controller (APU-Analog processing unit, DPU-Digital processing unit) Optic Head (MEMS Type, XS Type) Function Generator Power Supply Testing

More information

Wavelength Control and Locking with Sub-MHz Precision

Wavelength Control and Locking with Sub-MHz Precision Wavelength Control and Locking with Sub-MHz Precision A PZT actuator on one of the resonator mirrors enables the Verdi output wavelength to be rapidly tuned over a range of several GHz or tightly locked

More information

Frequency Scanned Interferometer Demonstration System

Frequency Scanned Interferometer Demonstration System Frequency Scanned Interferometer Demonstration System Jason Deibel, Sven Nyberg, Keith Riles, Haijun Yang University of Michigan, Ann Arbor American Linear Collider Workshop SLAC, Stanford University January

More information

queensgate a brand of Elektron Technology

queensgate a brand of Elektron Technology NanoSensors NX/NZ NanoSensor The NanoSensor is a non-contact position measuring system based on the principle of capacitance micrometry. Two sensor plates, a Target and a Probe, form a parallel plate capacitor.

More information

Review of the magnetic measurement technique (experience of the SLC, LEP, CEBAF)

Review of the magnetic measurement technique (experience of the SLC, LEP, CEBAF) Review of the magnetic measurement technique (experience of the SLC, LEP, CEBAF) N.A.Morozov Workshop on the TESLA spectrometer, Dubna, 13-14 October 2003 1..Stanford Linear Collider (SLC) To implement

More information

Computer Generated Holograms for Optical Testing

Computer Generated Holograms for Optical Testing Computer Generated Holograms for Optical Testing Dr. Jim Burge Associate Professor Optical Sciences and Astronomy University of Arizona jburge@optics.arizona.edu 520-621-8182 Computer Generated Holograms

More information

Improving a commercially available heterodyne laser interferometer to sub-nm uncertainty

Improving a commercially available heterodyne laser interferometer to sub-nm uncertainty Improving a commercially available heterodyne laser interferometer to sub-nm uncertainty H. Haitjema, S.J.A.G. Cosijns, N.J.J. Roset and M.J.Jansen Eindhoven University of Technology, PO Box 513, 56 MB

More information

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor Development of a Low Cost 3x3 Coupler Mach-Zehnder Interferometric Optical Fibre Vibration Sensor Kai Tai Wan Department of Mechanical, Aerospace and Civil Engineering, Brunel University London, UB8 3PH,

More information

Implementation of an Accelerometer Transverse Sensitivity Measurement System. By: Ian Veldman 3 to 5 September 2012

Implementation of an Accelerometer Transverse Sensitivity Measurement System. By: Ian Veldman 3 to 5 September 2012 Implementation of an Accelerometer Transverse Sensitivity Measurement System By: Ian Veldman 3 to 5 September 2012 NMISA 2012 Overview Introduction Transverse Sensitivity System description Measurement

More information

Frequency Scanned Interferometer Demonstration System

Frequency Scanned Interferometer Demonstration System Wright State University CORE Scholar Physics Faculty Publications Physics 1-2005 Frequency Scanned Interferometer Demonstration System Jason A. Deibel Wright State University - Main Campus, jason.deibel@wright.edu

More information

Thickness Measurement with Laser Displacement Sensors

Thickness Measurement with Laser Displacement Sensors Thickness Measurement with Laser Displacement Sensors Laser displacement sensors are often used for measuring distance, movement and dimensions. If the measured values from two sensors are evaluated together,

More information

Servo Track Writing Technology

Servo Track Writing Technology UDC 681.327.11:681.327.634 Servo Track Writing Technology vyukihiro Uematsu vmasanori Fukushi (Manuscript received September 11, 21) To achieve an ultra high track density in hard disk drives, the track-following

More information

THE ORION PHOTOINJECTOR: STATUS and RESULTS

THE ORION PHOTOINJECTOR: STATUS and RESULTS THE ORION PHOTOINJECTOR: STATUS and RESULTS Dennis T. Palmer SLAC / ARDB ICFA Sardinia 4 July 2002 1. Introduction 2. Beam Dynamics Simulations 3. Photoinjector 1. RF Gun 2. Solenoidal Magnet 3. Diagnostics

More information

CORPORATE PRESENTATION

CORPORATE PRESENTATION CORPORATE PRESENTATION WHO WE ARE Edmund Optics is a global OPTICS and IMAGING company that manufactures and supplies the worldwide technical community with precision optical components and subassemblies.

More information

A Multiwavelength Interferometer for Geodetic Lengths

A Multiwavelength Interferometer for Geodetic Lengths A Multiwavelength Interferometer for Geodetic Lengths K. Meiners-Hagen, P. Köchert, A. Abou-Zeid, Physikalisch-Technische Bundesanstalt, Braunschweig Abstract: Within the EURAMET joint research project

More information

A Penning Trap for Precision Spectroscopy of Highly Charged Ions at HITRAP. Jörg Krämer University of Mainz

A Penning Trap for Precision Spectroscopy of Highly Charged Ions at HITRAP. Jörg Krämer University of Mainz A Penning Trap for Precision Spectroscopy of Highly Charged Ions at HITRAP University of Mainz Experimental Goal Precise measurement of the hyperfine splitting in highly charged ions (HCI) as a test of

More information

UPGRADE OF THE MEDIUM AND HIGH FREQUENCY VIBRATION CALIBRATION REFERENCE EQUIPMENT AND EXTENSION TO LOW FREQUENCIES

UPGRADE OF THE MEDIUM AND HIGH FREQUENCY VIBRATION CALIBRATION REFERENCE EQUIPMENT AND EXTENSION TO LOW FREQUENCIES XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 9, Lisbon, Portugal UPGRADE OF THE MEDIUM AND HIGH FREQUENCY VIBRATION CALIBRATION REFERENCE EQUIPMENT AND EXTENSION TO LOW FREQUENCIES

More information

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components Thomas J. Dunn, Robert Michaels, Simon Lee, Mark Tronolone, and Andrew Kulawiec; Corning Tropel

More information

Measuring the speed of light

Measuring the speed of light 1 Purpose and comments Determine the speed of light by sending a laser beam through various mediums. Unless you want to see like Helen Keller, do not place your eyes in the beam path. Also, Switch the

More information

Cold-Head Vibrations of a Coaxial Pulse Tube Refrigerator

Cold-Head Vibrations of a Coaxial Pulse Tube Refrigerator Cold-Head Vibrations of a Coaxial Pulse Tube Refrigerator T. Koettig 1, F. Richter 2, C. Schwartz 2, R. Nawrodt 2, M. Thürk 2 and P. Seidel 2 1 CERN, AT-CRG-CL, CH-1211 Geneva 23, Switzerland 2 Friedrich-Schiller-Universität

More information

Paul Scherrer Institute Pierre-André Duperrex. On-line calibration schemes for RF-based beam diagnostics

Paul Scherrer Institute Pierre-André Duperrex. On-line calibration schemes for RF-based beam diagnostics Paul Scherrer Institute Pierre-André Duperrex On-line calibration schemes for RF-based beam diagnostics HB2012 Beijing, 17-20 Sept. 2012 Motivation Current monitor Some difficulties related to RF signal

More information

CALIBRATION PROCEDURE FOR STABILIZED LASERS USING THE METHOD OF OPTICAL BEATS MEASUREMENT UNCERTAINTY

CALIBRATION PROCEDURE FOR STABILIZED LASERS USING THE METHOD OF OPTICAL BEATS MEASUREMENT UNCERTAINTY U.P.B. Sci. Bull., Series A, Vol. 69, No. 1, 007 ISSN 13-707 CALIBRATION PROCEDURE FOR STABILIZED LASERS USING THE METHOD OF OPTICAL BEATS MEASUREMENT UNCERTAINTY Elena DUGHEANU 1 Lucrarea descrie metoda

More information

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO. 990-60700-9801 GEOTECH INSTRUMENTS, LLC 10755 SANDEN DRIVE DALLAS, TEXAS 75238-1336 TEL: (214) 221-0000 FAX: (214) 343-4400

More information

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

SUPPLEMENTARY INFORMATION DOI: /NPHOTON Supplementary Methods and Data 1. Apparatus Design The time-of-flight measurement apparatus built in this study is shown in Supplementary Figure 1. An erbium-doped femtosecond fibre oscillator (C-Fiber,

More information

LISA and SMART2 Optical Work in Europe

LISA and SMART2 Optical Work in Europe LISA and SMART2 Optical Work in Europe David Robertson University of Glasgow Outline Overview of current optical system work Title Funded by Main focus Prime Phase Measuring System LISA SMART2 SEA (Bristol)

More information

Figure 4.1 Vector representation of magnetic field.

Figure 4.1 Vector representation of magnetic field. Chapter 4 Design of Vector Magnetic Field Sensor System 4.1 3-Dimensional Vector Field Representation The vector magnetic field is represented as a combination of three components along the Cartesian coordinate

More information

A Thermal Compensation System for the gravitational wave detector Virgo

A Thermal Compensation System for the gravitational wave detector Virgo A Thermal Compensation System for the gravitational wave detector Virgo M. Di Paolo Emilio University of L Aquila and INFN Roma Tor Vergata On behalf of the Virgo Collaboration Index: 1) Thermal Lensing

More information

CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO

CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO 16063-41 Dr.-Ing. Uwe Buehn

More information

Templates, DTR and BPM Media

Templates, DTR and BPM Media Complete Metrology Solutions Imprint Technology Templates, DTR and BPM Media Simultaneous and Non-Destructive Measurements of Depth Top and Bottom CD Residual Layer Thickness, RLT DLC Thickness Side Wall

More information

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor Fausto ~cernese*', Rosario De ~ osa*~, Luciano Di Fiore*, Fabio ~arufi*', Adele La ~ana*' and Leopoldo

More information

Enhancing the capability of primary calibration system for shock acceleration in NML

Enhancing the capability of primary calibration system for shock acceleration in NML Enhancing the capability of primary calibration system for shock acceleration in NML Jiun-Kai CHEN 1 ; Yen-Jong HUANG 1 1 Center for Measurement Standards, Industrial Technology Research Institute, R.O.C.

More information

Low Vibration, Low Thermal Fluctuation System for Pulse Tube and Gifford- McMahon Cryocoolers

Low Vibration, Low Thermal Fluctuation System for Pulse Tube and Gifford- McMahon Cryocoolers Low Vibration, Low Thermal Fluctuation System for Pulse Tube and Gifford- McMahon Cryocoolers L. Mauritsen, D. Snow, A. Woidtke, M. Chase, and I. Henslee S2 Corporation Bozeman, MT ABSTRACT A compact,

More information

Fabrication of Probes for High Resolution Optical Microscopy

Fabrication of Probes for High Resolution Optical Microscopy Fabrication of Probes for High Resolution Optical Microscopy Physics 564 Applied Optics Professor Andrès La Rosa David Logan May 27, 2010 Abstract Near Field Scanning Optical Microscopy (NSOM) is a technique

More information

Frequency Scanned Interferometer for LC Tracker Alignment

Frequency Scanned Interferometer for LC Tracker Alignment Frequency Scanned Interferometer for LC Tracker Alignment Hai-Jun Yang, Sven Nyberg, Keith Riles University of Michigan, Ann Arbor Victoria Linear Collider Workshop British Columbia, Canada July 28-31,

More information

Superconducting RF Cavity Performance Degradation after Quenching in Static Magnetic Field

Superconducting RF Cavity Performance Degradation after Quenching in Static Magnetic Field Superconducting RF Cavity Performance Degradation after Quenching in Static Magnetic Field T. Khabiboulline, D. Sergatskov, I. Terechkine* Fermi National Accelerator Laboratory (FNAL) *MS-316, P.O. Box

More information

Technical capabilities of military calibration laboratories

Technical capabilities of military calibration laboratories Technical capabilities of military calibration laboratories Measurement domain Measuring range Measurement Remarks 3 ACCELERATION, VELOCITY AND DISTANCE Acceleration of Vibration - sensitivity (0,1 1000

More information

Nanometer-level repeatable metrology using the Nanoruler

Nanometer-level repeatable metrology using the Nanoruler Nanometer-level repeatable metrology using the Nanoruler Paul T. Konkola, a) Carl G. Chen, Ralf K. Heilmann, Chulmin Joo, Juan C. Montoya, Chih-Hao Chang, and Mark L. Schattenburg Massachusetts Institute

More information

Polarization Experiments Using Jones Calculus

Polarization Experiments Using Jones Calculus Polarization Experiments Using Jones Calculus Reference http://chaos.swarthmore.edu/courses/physics50_2008/p50_optics/04_polariz_matrices.pdf Theory In Jones calculus, the polarization state of light is

More information

How are X-ray slides formed?

How are X-ray slides formed? P3 Revision. How are X-ray slides formed? X-rays can penetrate soft tissue but not bone. X-rays are absorbed more by some materials than others. Photographic film can be used to detect X-rays, but these

More information

Electro-optic components and system

Electro-optic components and system Electro-optic components and system Optical Isolators 700 Series Faraday Rotator and Accessories The unique feature of a Faraday rotator is its nonreciprocity, that is, the fact that the "handedness" of

More information

MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION WHEEL

MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION WHEEL IMPACT: International Journal of Research in Engineering & Technology (IMPACT: IJRET) ISSN 2321-8843 Vol. 1, Issue 4, Sep 2013, 1-6 Impact Journals MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION

More information

Tutorial: 3D Scanning Vibrometry for. IMAC XXVII D. E. Oliver, Polytec, Inc.

Tutorial: 3D Scanning Vibrometry for. IMAC XXVII D. E. Oliver, Polytec, Inc. Tutorial: 3D Scanning Vibrometry for Structural Dynamics Measurements IMAC XXVII D. E. Oliver, Polytec, Inc. Content Principles of Laser Doppler Vibrometry Scanning Laser Doppler Vibrometry (SLDV) Limitations

More information

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn 3D Optical Motion Analysis of Micro Systems Heinrich Steger, Polytec GmbH, Waldbronn SEMICON Europe 2012 Outline Needs and Challenges of measuring Micro Structure and MEMS Tools and Applications for optical

More information

Integrated Optical Waveguide Sensor for Lighting Impulse Electric Field Measurement

Integrated Optical Waveguide Sensor for Lighting Impulse Electric Field Measurement PHOTONIC SENSORS / Vol. 4, No. 3, 2014: 215 219 Integrated Optical Waveguide Sensor for Lighting Impulse Electric Field Measurement Jiahong ZHANG *, Fushen CHEN, Bao SUN, and Kaixin CHEN Key Laboratory

More information

APPLICATION NOTE TURBINE BLADE TIP MEASUREMENTS

APPLICATION NOTE TURBINE BLADE TIP MEASUREMENTS Philtec APPLICATION NOTE Aug TURBINE BLADE TIP MEASUREMENTS 4 mm mm mm 44 mm Two turbine blade samples are shown here:. One blade p measures mm wide x 44 mm long with rough ground surface. One blade p

More information

Absolute distance interferometer in LaserTracer geometry

Absolute distance interferometer in LaserTracer geometry Absolute distance interferometer in LaserTracer geometry Corresponding author: Karl Meiners-Hagen Abstract 1. Introduction 1 In this paper, a combination of variable synthetic and two-wavelength interferometry

More information

Surface Micromachining

Surface Micromachining Surface Micromachining An IC-Compatible Sensor Technology Bernhard E. Boser Berkeley Sensor & Actuator Center Dept. of Electrical Engineering and Computer Sciences University of California, Berkeley Sensor

More information

New Long Stroke Vibration Shaker Design using Linear Motor Technology

New Long Stroke Vibration Shaker Design using Linear Motor Technology New Long Stroke Vibration Shaker Design using Linear Motor Technology The Modal Shop, Inc. A PCB Group Company Patrick Timmons Calibration Systems Engineer Mark Schiefer Senior Scientist Long Stroke Shaker

More information

INTERPLANT STANDARD - STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION OF SENSOR MEASUREMENTS OF LENGTH OF ROLLED MATERIALS IPSS: 2-07-037-13 (First Revision) Corresponding Indian Standard does not exist Formerly-: IPSS:

More information

TechNote. T001 // Precise non-contact displacement sensors. Introduction

TechNote. T001 // Precise non-contact displacement sensors. Introduction TechNote T001 // Precise non-contact displacement sensors Contents: Introduction Inductive sensors based on eddy currents Capacitive sensors Laser triangulation sensors Confocal sensors Comparison of all

More information

S.No Description/Specifications Qty 01. Post office box Trainer.

S.No Description/Specifications Qty 01. Post office box Trainer. Specification of Equipments for Physics lab S.No Description/Specifications Qty 01. Post office box Trainer. 06 The trainer should have: On Board DC Power Supply : 5V Galvanometer ; Deflection : 30 0 30

More information

(A) 2f (B) 2 f (C) f ( D) 2 (E) 2

(A) 2f (B) 2 f (C) f ( D) 2 (E) 2 1. A small vibrating object S moves across the surface of a ripple tank producing the wave fronts shown above. The wave fronts move with speed v. The object is traveling in what direction and with what

More information

LASER VIBROMETER CALIBRATION AT HIGH FREQUENCIES USING CONVENTIONAL CALIBRATION EQUIPMENT

LASER VIBROMETER CALIBRATION AT HIGH FREQUENCIES USING CONVENTIONAL CALIBRATION EQUIPMENT XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 009, Lisbon, Portugal LASER VIBROMETER CALIBRATION AT HIGH FREQUENCIES USING CONVENTIONAL CALIBRATION EQUIPMENT Thomas Bruns,

More information

A refractivity-compensated absolute distance interferometer as prospective novel primary standard for baseline calibrations

A refractivity-compensated absolute distance interferometer as prospective novel primary standard for baseline calibrations A refractivity-compensated absolute distance interferometer as prospective novel primary standard for baseline calibrations (1), Alen Bošnjakovic (2) and Florian Pollinger (1) (1) Physikalisch-Technische

More information

Commissioning of Advanced Virgo

Commissioning of Advanced Virgo Commissioning of Advanced Virgo VSR1 VSR4 VSR5/6/7? Bas Swinkels, European Gravitational Observatory on behalf of the Virgo Collaboration GWADW Takayama, 26/05/2014 B. Swinkels Adv. Virgo Commissioning

More information

The LTP interferometer aboard SMART-2

The LTP interferometer aboard SMART-2 The LTP interferometer aboard SMART-2 Gerhard Heinzel Max-Planck-Institut für Gravitationsphysik, (Albert-Einstein-Institut), Hannover, presented at the LISA Symposium, PSU, 22.7.2002 1 What is SMART-2?

More information

CubeSat Proximity Operations Demonstration (CPOD) Vehicle Avionics and Design

CubeSat Proximity Operations Demonstration (CPOD) Vehicle Avionics and Design CubeSat Proximity Operations Demonstration (CPOD) Vehicle Avionics and Design August CubeSat Workshop 2015 Austin Williams VP, Space Vehicles CPOD: Big Capability in a Small Package Communications ADCS

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Acceso III No. 16 A Nave 10, Parque Industrial Benito

More information

Magnetic Field Compensation System MR-3

Magnetic Field Compensation System MR-3 Magnetic Field Compensation System MR-3 (DC 1kHz) (DC 10kHz) Description Magnetic Field Compensation System MR-3 can compensate the magnetic field which is measured in three axes. Therefore, it can reduce

More information

Physics 319 Laboratory: Optics

Physics 319 Laboratory: Optics 1 Physics 319 Laboratory: Optics Birefringence II Objective: Previously, we have been concerned with the effect of linear polarizers on unpolarized and linearly polarized light. In this lab, we will explore

More information

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

SmartSenseCom Introduces Next Generation Seismic Sensor Systems SmartSenseCom Introduces Next Generation Seismic Sensor Systems Summary: SmartSenseCom, Inc. (SSC) has introduced the next generation in seismic sensing technology. SSC s systems use a unique optical sensing

More information

Rotary Encoder System Compact Model Range

Rotary Encoder System Compact Model Range we set the standards RIK Rotary Encoder System Compact Model Range 2 Incremental rotary encoder Features Compact design, consisting of scanning head with round cable, 15pin D-sub connector and grating

More information

Understanding Optical Specifications

Understanding Optical Specifications Understanding Optical Specifications Optics can be found virtually everywhere, from fiber optic couplings to machine vision imaging devices to cutting-edge biometric iris identification systems. Despite

More information

Characterization of Actinic Mask Blank Inspection for Improving Sensitivity

Characterization of Actinic Mask Blank Inspection for Improving Sensitivity Characterization of Actinic Mask Blank Inspection for Improving Sensitivity Yoshihiro Tezuka, Toshihiko Tanaka, Tsuneo Terasawa, Toshihisa Tomie * M-ASET, Tsukuba, Japan * M-ASRC, AIST, Tsukuba, Japan

More information

How Resonance Data is Used

How Resonance Data is Used Leading Edge Suspension Resonance Control and Technology DISKCON AP, March 2007 Introduction Increasingly, suspension resonance characterization and process control have become critical factors in drive

More information

Broadband laser ranging for explosive experiments

Broadband laser ranging for explosive experiments DOE/NV/25946--2828 Broadband laser ranging for explosive experiments B. La Lone, B. Marshall, C. V. Bennett, a P. Younk, b K. Miller, E. Daykin National Security Technologies, LLC Special Technologies

More information

The design of a radio frequency quadrupole LINAC for the RIB project at VECC Kolkata

The design of a radio frequency quadrupole LINAC for the RIB project at VECC Kolkata PRAMANA cfl Indian Academy of Sciences Vol. 59, No. 6 journal of December 2002 physics pp. 957 962 The design of a radio frequency quadrupole LINAC for the RIB project at VECC Kolkata V BANERJEE 1;Λ, ALOK

More information

Periodic Error Correction in Heterodyne Interferometry

Periodic Error Correction in Heterodyne Interferometry Periodic Error Correction in Heterodyne Interferometry Tony L. Schmitz, Vasishta Ganguly, Janet Yun, and Russell Loughridge Abstract This paper describes periodic error in differentialpath interferometry

More information

DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT

DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT DEVELOPMENT OF A BETA 0.12, 88 MHZ, QUARTER WAVE RESONATOR AND ITS CRYOMODULE FOR THE SPIRAL2 PROJECT G. Olry, J-L. Biarrotte, S. Blivet, S. Bousson, C. Commeaux, C. Joly, T. Junquera, J. Lesrel, E. Roy,

More information

Length and Position Measurement

Length and Position Measurement Length and Position Measurement Primary standards were once based on the length of a bar of metal at a given temperature. The present standard is: 1 meter = distance traveled by light in a vacuum in 3.335641

More information

Description of options, upgrades and accessories for the laser beam stabilization system Compact

Description of options, upgrades and accessories for the laser beam stabilization system Compact Description of options, upgrades and accessories for the laser beam stabilization system Compact The basic configuration of the Compact laser beam stabilization system is fully equipped for stabilization

More information

Electromagnetic Radiation

Electromagnetic Radiation Electromagnetic Radiation EMR Light: Interference and Optics I. Light as a Wave - wave basics review - electromagnetic radiation II. Diffraction and Interference - diffraction, Huygen s principle - superposition,

More information

PAGE 1/6 ISSUE Jul SERIES Micro-SPDT PART NUMBER R516 XXX 10X R 516 _ 1 0 _

PAGE 1/6 ISSUE Jul SERIES Micro-SPDT PART NUMBER R516 XXX 10X R 516 _ 1 0 _ PAGE 1/6 ISSUE Jul-24-2017 SERIES Micro-SPDT PART NUMBER R516 XXX 10X R516 series: the RAMSES concept merges with the SLIM LINE technology, breaking up the frequency limits of SMT switches : - FULL SMT

More information

MEASUREMENT OF POSITIONING ACCURACY IN 1 AXIS

MEASUREMENT OF POSITIONING ACCURACY IN 1 AXIS LS 100 MEASUREMENT OF POSITIONING ACCURACY IN 1 AXIS This is the basic configuration. It is designed for positional calibrations of machine tools, coordinate measuring machines, universal length meters

More information

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015 Issued: Monday, April 27, 2015 PROBLEM SET #7 Due (at 9 a.m.): Friday, May 8, 2015, in the EE C247B HW box near 125 Cory. Gyroscopes are inertial sensors that measure rotation rate, which is an extremely

More information

Variation in Multimode Fiber Response: Summary of Experimental Results

Variation in Multimode Fiber Response: Summary of Experimental Results Summary of Experimental Results IEEE P802.3aq 10GBASE-LRM, Task Group 4 November, 2004, San Antonio Infineon Fiber Optics, Infineon Fiber Optics Page 1 Summary of Experimental Results! Introduction A variation

More information

Section 2: Lithography. Jaeger Chapter 2. EE143 Ali Javey Slide 5-1

Section 2: Lithography. Jaeger Chapter 2. EE143 Ali Javey Slide 5-1 Section 2: Lithography Jaeger Chapter 2 EE143 Ali Javey Slide 5-1 The lithographic process EE143 Ali Javey Slide 5-2 Photolithographic Process (a) (b) (c) (d) (e) (f) (g) Substrate covered with silicon

More information

High-Speed 3D Sensor with Micrometer Resolution Ready for the Production Floor

High-Speed 3D Sensor with Micrometer Resolution Ready for the Production Floor High-Speed 3D Sensor with Micrometer Resolution Ready for the Production Floor Industrial VISION days 2011 10.11.2011 Christian Lotto acquisiton Speed, vibration tolerance Challenge: High Precision on

More information

Saturation of Active Loop Antennas

Saturation of Active Loop Antennas Saturation of Active Loop Antennas Alexander Kriz EMC and Optics Seibersdorf Laboratories 2444 Seibersdorf, Austria Abstract The EMC community is working towards shorter test distances for radiated emission

More information

DTU DANCHIP an open access micro/nanofabrication facility bridging academic research and small scale production

DTU DANCHIP an open access micro/nanofabrication facility bridging academic research and small scale production DTU DANCHIP an open access micro/nanofabrication facility bridging academic research and small scale production DTU Danchip National Center for Micro- and Nanofabrication DTU Danchip DTU Danchip is Denmark

More information

Agilent 10705A Single Beam Interferometer and Agilent 10704A Retroreflector

Agilent 10705A Single Beam Interferometer and Agilent 10704A Retroreflector 7B Agilent 10705A Single Beam Interferometer and Agilent 10704A Retroreflector Description Description The Agilent 10705A Single Beam Interferometer (shown in Figure 7B-1) is intended for use in low-mass

More information

Chapter 7. Optical Measurement and Interferometry

Chapter 7. Optical Measurement and Interferometry Chapter 7 Optical Measurement and Interferometry 1 Introduction Optical measurement provides a simple, easy, accurate and reliable means for carrying out inspection and measurements in the industry the

More information

Stability of a Fiber-Fed Heterodyne Interferometer

Stability of a Fiber-Fed Heterodyne Interferometer Stability of a Fiber-Fed Heterodyne Interferometer Christoph Weichert, Jens Flügge, Paul Köchert, Rainer Köning, Physikalisch Technische Bundesanstalt, Braunschweig, Germany; Rainer Tutsch, Technische

More information

New Focus High Speed Photoreceivers

New Focus High Speed Photoreceivers New Focus High Speed 1 About New Focus Products Newport s New Focus products are among our most innovative, high-performance, high-quality, and easy-to-use photonics tools and equipment. They include exceptional

More information

REAL TIME THICKNESS MEASUREMENT OF A MOVING WIRE

REAL TIME THICKNESS MEASUREMENT OF A MOVING WIRE REAL TIME THICKNESS MEASUREMENT OF A MOVING WIRE Bini Babu 1, Dr. Ashok Kumar T 2 1 Optoelectronics and communication systems, 2 Associate Professor Model Engineering college, Thrikkakara, Ernakulam, (India)

More information

Laboratory Report INFN Milano LASA

Laboratory Report INFN Milano LASA Laboratory Report INFN Milano LASA Activities Underway Wire Position Monitor: new generation WPMs mounted on cryomodule and readout connected to control system Piezo Vibration Control: microphonic control

More information

Spectrally resolved frequency comb interferometry for long distance measurement

Spectrally resolved frequency comb interferometry for long distance measurement Spectrally resolved frequency comb interferometry for long distance measurement Steven van den Berg, Sjoerd van Eldik, Nandini Bhattacharya Workshop Metrology for Long Distance Surveying 21 November 2014

More information

First step in the industry-based development of an ultra-stable optical cavity for space applications

First step in the industry-based development of an ultra-stable optical cavity for space applications First step in the industry-based development of an ultra-stable optical cavity for space applications B. Argence, E. Prevost, T. Levêque, R. Le Goff, S. Bize, P. Lemonde and G. Santarelli LNE-SYRTE,Observatoire

More information

DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS

DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS Stephen E. Maxwell, Sensor Science Division, PML Kevin O. Douglass, David F. Plusquellic, Radiation and Biomolecular Physics Division, PML

More information

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers.

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers. 295 ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers. CERN, CH-1211 Geneva 23, Switzerland Introduction Electromagnets

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 MTS METROLOGY AND CALIBRATION LABORATORY 14000 Technology Drive Eden Prairie, MN 55344 Kevin Rust Phone: 952 937 4790 www.mts.com CALIBRATION

More information