1 MEANPR23 TEST REPORT Energy consumption / efficiency of electrical and electronic products Report Reference No. : Tested by (name + signature) Approved by (name + signature) : Tony Chen : Cheery Wu Date of issue : Testing Laboratory Testing location / address Applicant Address : : 10F, #250 Jiangchangsan Road, Building 16,Headquarter Economy Park Shibei HiTech Park, Zhabei District, Shanghai, , China : Philips Consumer Lifestyle B.V. : Building TC, Tussendiepen 4, 9206 AD Drachten, The Netherlands Test specification: Standard(s) : EN 50564:2011 Test procedure : Commission Regulation (EC) No. 1275/2008 of 17 December 2008 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment Test object description : Philips AVENT electric steam steriliser Trade Mark...: PHILIPS AVENT Manufacturer...: Philips Consumer Lifstyle B.V. Address...: Building TC, Tussendiepen 4, 9206 AD Drachten, The Netherlands. Model/Type reference...: SCF922 Ratings...: 220 V~, 50 Hz, 550 W or V~, 5060 Hz, 550 W; Class I Number of test objects Possible test case verdicts: test case does not apply to the test object test object does meet the requirement test object does not meet the requirement Test program : 1 pc : : P(Pass) : F(Fail) : The test object has been submitted to a test program as mentioned on the next pages. The test results shown in this report relate only to the tests performed according to the test program. Integral publication of this document is allowed. Member of the DEKRA Networ

2 MEANPR23 Page 2 of 9 Summary of testing: Comply with Commission Regulation (EC) 1275/2008: Stage 1, Stage 2, PASS Model Power consumption measurement (W) Availability of standby/ Power Standby mode Off mode off mode management SCF922 No Yes No No

3 MEANPR23 Page 3 of 9 Copy of marking plate:

4 MEANPR23 Page 4 of 9 Product Picture (Representative) General product information : The submitted product is steam sterilizer intended for household use only and which is used to sterilize the feedingbottle. Copyright KEMA Quality B.V., Arnhem, the Netherlands. All rights reserved.

5 MEANPR23 Page 5 of 9 1 TEST PARAMETERS AND PROCEDURE Applied standard.....: EN 50564:2011 Ambient temperature 23+/5 C 23,0 Power supply test voltage and frequency accuracy....: Supply voltage waveform total harmonic distortion of the supply system....: 230 V ± 1%, 50 Hz ±1% 2% Measurement uncertainty....: 0,01 W For MCR<=10 Power of 1,0 W or greater : 2% at 95% confidence level Power less than 1,0 W : 0,02 W at 95% confidence level For MCR>10 Power of 1,0 W or greater : the maximum permitted relative uncertainty introduced by the power measurement equipment shall be equal to or less than Upc at the 95 % confidence level. Power less than 1,0 W : 0,02 W at 95% confidence level the permitted absolute uncertainty shall be the greater of Uma (0,02 W) or Upc when expressed as an absolute uncertainty in W (Upc measured value) at the 95 % confidence level. P P Measurement Procedure The sampling method: by the use of an instrument to record power measurements at regular intervals throughout the measurement period. Sampling is the preferred method of measurement for all modes and product types under this standard. For modes where power varies in a cyclic fashion or is unstable, or for limited duration modes, sampling is the only measurement method permitted under this standard; or The average reading method: where the power value is stable and the mode is stable, by averaging the instrument power readings over a specified period or, alternatively by recording the energy consumption over a specified period and dividing by the time; or The direct meter reading method: where the power value is stable and the mode is stable, by recording the instrument power reading. P

6 MEANPR23 Page 6 of 9 2 POWER CONSUMPTION MEASUREMENT Operating mode selection of mode or programming Only offmode of clause 2,1 available Sequence of events to reach the mode where the equipments automatically changes mode to OFF mode and or Standby mode. Not applicable Other information to the operation mode Power value measured under stable condition Yes No Test procedure Verification test (3 samples) Type test (1 sample) 2.1 Offmode Measured value in mw Sample 01 Sample 02 Sample 03 Data: 0 mw Data: Data: Average (Reported value in watts rounded to the second decimal place, for loads greater than or equal to 10W, three significant figures shall be reported.) 0 W 2.2 Standbymode (The equipment in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function) Measured value in mw Sample 01 Sample 02 Sample 03 Data: Data: Data: Average (Reported value in watts rounded to the second decimal place, for loads greater than or equal to 10w, three significant figures shall be reported.) 2.3 Standbymode (The equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display) Measured value in mw Sample 01 Sample 02 Sample 03 Data: Data: Data: Average (Reported value in watts rounded to the second decimal place, for loads greater than or equal to 10w, three significant figures shall be reported.)

7 MEANPR23 Page 7 of 9 3 COMPLIANCE WITH COMISSION REGULATION (EC) No. 1275/2008 One year after regulation has become into force Limit Measured OFF mode......: 1,00 W Standby mode with any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function Standby mode any condition providing only information or status display, or providing only a combination of reactivation function and information or status display 1,00 W 2,00 W Sampling 1 unit / Average of 3 units 4 years after regulation has become into force Limit Measured OFF mode......: 0,50 W 0 W P Standby mode with any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function Standby mode any condition providing only information or status display, or providing only a combination of reactivation function and information or status display 0,50 W 1,00 W Sampling 1 unit / Average of 3 units 4 AVAILABILITY OF OFF MODE AND / OR STANDBY MODE AND POWER MANAGEMENT Equipment provided with, Off mode and/or Standby mode, and/or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source (except where this is inappropriate for the intended use)

8 MEANPR23 Page 8 of 9 When equipment is not providing the main function, or when other energy using product(s) are not dependent on its functions, equipment shall, unless inappropriate for the intended use, offer a power management function, or a similar function, that switches equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into Standby mode, or Off mode, or Another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source. The power management function shall be activated before delivery. If above criteria can not be met, three more units shall be tested. The model shall be considered to comply with this regulation n if the average of the results of the latter three tests for offmode and/or standby mode conditions, as applicable, does not exceed the limit values by more than 10%. 5 VERIFICATION PROCEDURE ANNEX III ACCEPTANCE CRITERIA Power 1 W The model shall be considered to comply with the regulation if the results for offmode and/or standby mode conditions, as applicable, do not exceed the limit values by more than 10%. If above criteria can not be met, three more units shall be tested. The model shall be considered to comply with this regulation if the average of the results of the latter three tests for offmode and/or standby mode conditions, as applicable, does not exceed the limit values by more than 10%. Power 1 W The model shall be considered to comply with the regulation if the results for offmode and standby mode conditions, as applicable, do not exceed the limit values by more than 0.10 W If above criteria can not be met, three more units shall be tested. The model shall be considered to comply with this regulation n if the average of the results of the latter three tests for offmode and/or standby mode conditions, as applicable, does not exceed the limit values by more than 0.10 W

9 MEANPR23 Page 9 of 9 6 USED EQUIPMENT LIST Measurement/ testing Registration Number Testing/measuring equipment/material used Range used Energy consumption SH 301 Digital Power Meter/ 0300V/0600V; YOKOGAWA/ WT A END OF REPORT Calibration date

Technical Documentation of (EU) No 617/2013

Technical Documentation of (EU) No 617/2013 Technical Documentation of (EU) No 617/2013 Product type Product category Manufacturer name, address Notebook computer A Acer Italy srl Viale De Gasperi 88/A 20017 Mazzo di Rho ( MI) Italy Product model

More information

Technical Documentation of (EU) No 617/2013

Technical Documentation of (EU) No 617/2013 Technical Documentation of (EU) No 617/2013 Product type Desktop computer Product category B D Manufacturer name, address Product model number Year of manufacture E TEC allowance with capability adjustments

More information

Standby Power. Primer

Standby Power. Primer Standby Power Primer Primer Table of Contents What is Standby Power?...3 Why is Standby Power Important?...3 How to Measure Standby Power...4 Requirements for a Measurement...4 Standby Measurement Challenges...4

More information

05e28 Di-electric Strength (High Voltage) Test and Leakage Current Test Proficiency Testing Program

05e28 Di-electric Strength (High Voltage) Test and Leakage Current Test Proficiency Testing Program instructions Di-electric Strength (High Voltage) Test and Leakage Current Test Proficiency Testing Program Please read the instructions carefully and perform the testing as directed. Should you have any

More information

INTERNATIONAL OIML R 103 RECOMMENDATION

INTERNATIONAL OIML R 103 RECOMMENDATION INTERNATIONAL OIML R 103 RECOMMENDATION Edition 1992 (E) Measuring instrumentation for human response to vibration (with reference to International Standards 8041 and 5347 of the International Organization

More information

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Number... : 246847 Date of issue... : October

More information

TPS 49 EDITION 2 JUNE 2009

TPS 49 EDITION 2 JUNE 2009 TPS 49 EDITION 2 JUNE 2009 Interim arrangements & guidance on the interpretation of IEC 61672 Sound Level Meters - Periodic Tests CONTENTS SECTION PAGE 1 Purpose and duration 2 2 Statement 2 3 Specific

More information

COURSE NOTES Testing Compliance to Energy Efficiency Standards

COURSE NOTES Testing Compliance to Energy Efficiency Standards COURSE NOTES Testing Compliance to Energy Efficiency Standards Introduction These course notes are to be read in association with the PI University video course, Testing Compliance to Energy Efficiency

More information

TEST REPORT IEC Safety of Transportable Motor-Operated Power Tools

TEST REPORT IEC Safety of Transportable Motor-Operated Power Tools Test Report issued under the responsibility of: STAYER IBÉRICA S.A TEST REPORT Safety of Transportable Motor-Operated Power Tools REPORT IDS TR_POTENZA160_SEG_01 Report Reference No. : TR_POTENZA160_SEG_01

More information

ETSI EN V1.3.1 ( )

ETSI EN V1.3.1 ( ) EN 300 422-2 V1.3.1 (2011-08) Harmonized European Standard Electromagnetic compatibility and Radio spectrum Matters (ERM); Wireless microphones in the 25 MHz to 3 GHz frequency range; Part 2: Harmonized

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 300 471-2 V1.1.1 (2001-05) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Rules for Access and

More information

Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes

Company Directive STANDARD TECHNIQUE: SD1E/2. Technical Requirements for Customer Export Limiting Schemes Company Directive STANDARD TECHNIQUE: SD1E/2 Technical Requirements for Customer Export Limiting Schemes Policy Summary This Standard Technique specifies the requirements for customer owned Export Limitation

More information

DFS MEASUREMENT REPORT EN V1.8.1 Clause 4.7

DFS MEASUREMENT REPORT EN V1.8.1 Clause 4.7 MRT Technology (Suzhou) Co., Ltd Report No.: 1609RSU03003 Phone: +86-512-66308358 Report Version: V03 Fax: +86-512-66308368 Issue Date: 12-07-2016 Web: www.mrt-cert.com DFS MEASUREMENT REPORT EN 301 893

More information

TEST REPORT COMMISSION REGULATION (EU)

TEST REPORT COMMISSION REGULATION (EU) Test Report issued under the responsibility of: SGS-CSTC TEST REORT COMMISSION REGULATION (EU) No 1194/2012 of 12 December 2012 implementing Directive 2009/125/EC of the European arliament and of the Council

More information

This Certificate consists of 75 pages in total.

This Certificate consists of 75 pages in total. Object Heat shrinkable indoor termination 1086-16 Type MZDNK-3-15-C Rated voltage, U 0 /U (U m ) 8,7/15 (17,5) kv Conductor material Cu Conductor cross-section 3 x 185 mm 2 Insulation material XLPE Manufacturer

More information

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements Test Report issued under the responsibility of: TEST REPORT IEC 60825-1 Safety of laser products - Part 1: Equipment classification and requirements Report Number.... : GZES160801248631 Date of issue...

More information

5520A. Multi-Product Calibrator. Extended Specifications 2005

5520A. Multi-Product Calibrator. Extended Specifications 2005 5520A Multi-Product Calibrator Extended Specifications 2005 5520A Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes,

More information

ETSI EN V1.2.1 ( )

ETSI EN V1.2.1 ( ) EN 300 113-2 V1.2.1 (2002-04) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land mobile service; Radio equipment intended

More information

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter. Key Features

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter. Key Features Digital Power Meter MODEL 6603/6604 Key Features DIGITAL POWER METER MODEL 6603/6604 Voltage Ranges : 15/30/60/150/300/600 Vrms, 100Vrms (optional kit) Current Ranges : 0.005/0.0/0.05/0./0.5//5/0 Arms

More information

ETSI EN V1.1.1 ( ) Harmonized European Standard (Telecommunications series)

ETSI EN V1.1.1 ( ) Harmonized European Standard (Telecommunications series) EN 302 617-2 V1.1.1 (2010-10) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Ground-based UHF radio transmitters, receivers and

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 300 219-2 V1.1.1 (2001-03) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment transmitting

More information

5520A. Multi-Product Calibrator. Extended Specifications

5520A. Multi-Product Calibrator. Extended Specifications 5520A Multi-Product Calibrator Extended Specifications Specifications The following tables list the 5520A specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or

More information

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER: A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report

More information

ETSI EN V1.2.1 ( ) Harmonized European Standard

ETSI EN V1.2.1 ( ) Harmonized European Standard EN 302 372-2 V1.2.1 (2011-02) Harmonized European Standard Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Equipment for Detection and Movement; Tanks Level Probing

More information

EU Declaration of Conformity Document number: 2016 / 9C1-3302680-EN-00 Manufacturer or representative: OSRAM GmbH Address: Marcel-Breuer-Str. 6 80807 München Germany Brand name or trade mark: Product type:

More information

About the power standards calibration in the National Institute of Metrology, Romania

About the power standards calibration in the National Institute of Metrology, Romania About the s calibration in the National nstitute of Metrology, Romania oana Odor 1, Dorin Flaminzeanu 2, Cornel Baltateanu 3, Dan Mihai Stefanescu 4 1 National nstitute of Metrology, Sos. Vitan-Barzesti,

More information

TEST REPORT IEC Photobiological safety of lamps and lamp systems

TEST REPORT IEC Photobiological safety of lamps and lamp systems TEST REORT hotobiological safety of lamps and lamp systems Report Reference No.... : SHES170800821171 Date of issue... : 2017-09-04 Total number of pages... : 15 Testing Laboratory... : Address... : Applicant

More information

IZAR RADIO. A safe form of radio

IZAR RADIO. A safe form of radio IZAR RADIO A safe form of radio 1 IZAR RADIO A safe form of radio 2 Radio-based technologies have found their way into almost all areas of our lives. And when it comes to recording consumption data, wireless

More information

ETSI EN V1.1.2 ( ) Harmonized European Standard

ETSI EN V1.1.2 ( ) Harmonized European Standard EN 302 729-2 V1.1.2 (2011-05) Harmonized European Standard Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Level Probing Radar (LPR) equipment operating in the

More information

WT210/WT at rated. 5 ma range. input Low current (WT210) DC 0.5 Hz. to100 khz. Digital Power Meters ±0.2% WT210/WT230 Digital Power Meters

WT210/WT at rated. 5 ma range. input Low current (WT210) DC 0.5 Hz. to100 khz. Digital Power Meters ±0.2% WT210/WT230 Digital Power Meters WT2/WT23 Digital Power Meters WT2/WT23 Digital Power Meters Digital Sampling Power Meters with Superior Cost Performance Low power measurement (IEC623) Harmonic measurement Compact design (half-rack size)

More information

VHF LAND MOBILE SERVICE

VHF LAND MOBILE SERVICE RFS21 December 1991 (Issue 1) SPECIFICATION FOR RADIO APPARATUS: VHF LAND MOBILE SERVICE USING AMPLITUDE MODULATION WITH 12.5 khz CARRIER FREQUENCY SEPARATION Communications Division Ministry of Commerce

More information

Australian Standard. Electricity metering equipment (AC) Particular requirements. Part 22: Static meters for active energy (classes 0.2 S and 0.

Australian Standard. Electricity metering equipment (AC) Particular requirements. Part 22: Static meters for active energy (classes 0.2 S and 0. AS 62053.22 2005 IEC 62053-22, Ed.1.0 (2003) AS 62053.22 2005 Australian Standard Electricity metering equipment (AC) Particular requirements Part 22: Static meters for active energy (classes 0.2 S and

More information

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax:

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax: POWER CORPORATION Power Quality Specifications and Guidelines for Customers Phone: 403-514-3700 Fax: 403-514-3719 1 GENERAL OVERVIEW........................................ 1.1 WHAT DOES THIS SPECIFICATION

More information

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products IESNA SUSTAINING MEMBER Date of issue Mar 17, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Rendered

More information

Australian Standard. Electricity metering equipment (AC) Particular requirements

Australian Standard. Electricity metering equipment (AC) Particular requirements AS 62053.21 2005 AS 62053.21 2005 Australian Standard Electricity metering equipment (AC) Particular requirements Part 21: Static meters for active energy (classes 1 and 2) (IEC 62053-21, Ed.1.0 (2003)

More information

TEST REPORT Title 47-Telecommunication

TEST REPORT Title 47-Telecommunication TEST REPORT Title 47-Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 5 - Radio Frequency Devices Subpart B - Unintentional Radiators Report Reference No....

More information

Connection of Embedded Generating Plant up to 5MW

Connection of Embedded Generating Plant up to 5MW Engineering Recommendation No.3 of the Electricity Distribution Code Connection of Embedded Generating Plant up to 5MW Version 1.0 30th November 2005 Prepared by: Al Ain Distribution Company, Abu Dhabi

More information

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( ) EN 300 341-2 V1.1.1 (2000-12) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile service (RP 02); Radio equipment

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-08-10 Page 1 of 27 Report Reference # E122103-A152-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

New Standards for Test and Calibration of Phasor Measurement Units

New Standards for Test and Calibration of Phasor Measurement Units New Standards for Test and Calibration of Phasor Measurement Units Jack Somppi Fluke Calibration NCSLI Conference Sacramento, CA August 2, 2012 2012 Fluke Corporation NCSLI PMU 20120802 1 Stability of

More information

TEST REPORT IEC Medical Electrical Equipment Part 1:General requirements for safety

TEST REPORT IEC Medical Electrical Equipment Part 1:General requirements for safety Issue Date: 2015-10-09 Page 1 of 124 Report Reference # E349607-A8-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60601-1 Medical Electrical Equipment Part

More information

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Scope: This specification defines the requirement of a Three

More information

LED DOWN LIGHT (Dimmable)

LED DOWN LIGHT (Dimmable) LED DOWN LIGHT (Dimmable) 72626 Size : Φ230x99mm(9.06x3.90") Characteristics Item Number 72626 Description 8 LED down light Voltage 120V AC Power 25W Dimmable Yes LED Type SMD CRI >90 Lumens 2000 lms Color

More information

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT For Tritech Technology Ltd. Unit B, 8/F, Chung Pont Commercial Building No. 300 Hennessy Road, WanChai, Hong Kong. Model: 209517 Report Type: Original

More information

TEST REPORT DIN V VDE V :2006 Automatic disconnecting device

TEST REPORT DIN V VDE V :2006 Automatic disconnecting device age 1 of 23 TEST REORT Automatic disconnecting device Report Reference No...: GZ10080033-1 Date of issue...: August 18, 2010 Total number of pages... 23 pages Testing Laboratory...: Address...: Tested

More information

FCC & IC TEST REPORT for Bluetooth Device No SHA-001

FCC & IC TEST REPORT for Bluetooth Device No SHA-001 Page 1 of 41 FCC & IC TEST REPORT for Bluetooth Device No. 161100632SHA-001 Applicant : Manufacturer : Product Name : SHENZHEN DNS INDUSTRIES CO., LTD. 23/F Building A, Shenzhen International Innovation

More information

Final draft ETSI EN V1.1.1 ( )

Final draft ETSI EN V1.1.1 ( ) Final draft EN 302 291-2 V1.1.1 (2005-05) Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Close

More information

5522A Multi-Product Calibrator Extended specifications

5522A Multi-Product Calibrator Extended specifications 5522A Multi-Product Calibrator Extended specifications General Specifications The following tables list the 5522A specifications. All specifications are valid after allowing a warm-up period of 30 minutes,

More information

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT For NanJing JingZe Lighting Technology Co.,Ltd No. 30, Hengfa Rd., National Economic Technological Development Zone, Nanjing, Jiangsu, China Tested Model:

More information

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

Always there to help you. Register your product and get support at  AJ3200. Question? Contact Philips. Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJ3200 User manual Contents 1 Important 2 2 Your clock radio 2 Introduction 2 What's

More information

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS AS 60044.1 2007 AS 60044.1 2007 Australian Standard Instrument transformers Part 1: Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD) This Australian Standard was prepared by Committee EL-013, Measurement

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: 241 Riverview Avenue. Newton MA 02466 505 Boul.du

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives 3.0 50HP @ 200 to 240V AC 3.0 350HP @ 380 to 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 285573 Date of issue...: 2015-09-15

More information

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER: A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 210282-CI3-2 CB DE1-56459 Date of issue...

More information

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-10R Extension number: 00. Driving beam : N/A

THE NETHERLANDS (N E D E R L A N D) COMMUNICATION. Approval number: E4-10R Extension number: 00. Driving beam : N/A Vehicle Technology Division THE NETHERLANDS (N E D E R L A N D) COMMUNICATION Concerning () : - approval granted - approval extended - approval refused - approval withdrawn - production definitely discontinued

More information

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators Extended Specifications These specifications apply to the 5520A-SC1100, 5500A- SC600 and 5500A-SC300 Oscilloscope Calibration

More information

Technical Requirements for Connecting Small Scale PV (sspv) Systems to Low Voltage Distribution Networks

Technical Requirements for Connecting Small Scale PV (sspv) Systems to Low Voltage Distribution Networks 2014 Technical Requirements for Connecting Small Scale PV (sspv) Systems to Low Voltage Distribution Networks This document specifies the technical requirement for connecting sspv to the low voltage distribution

More information

76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE

76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE 09-1026 TYPE TEST CERTIFICATE OF COMPLETE TYPE TEST OBJECT single-core power cable TYPE 76 / 132 (145) kv 1x1200 mm 2 CU/XLPE/CWS/AL/HDPE Rated voltage, U o /U (U m ) 76/132 (145) kv Conductor material

More information

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)

More information

LED Driver Constant voltage

LED Driver Constant voltage Product description Fixed output constant voltage built-in control gear for LED in 12/24 V Input voltage range 220 240 VAC Max. output power W Connection cable with stripped cable end (300 mm ±10 mm) Polarity

More information

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications These specifications apply to the 5520A-SC1100, 5500A-SC600 and 5500A-SC300 Oscilloscope Calibration

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

LMM31. Dimmer Micromodule, 1 load USER MANUAL 20410/ LMM31 ALL RIGHTS RESERVED MARMITEK

LMM31. Dimmer Micromodule, 1 load USER MANUAL 20410/ LMM31 ALL RIGHTS RESERVED MARMITEK LMM31 Dimmer Micromodule, 1 load USER MANUAL 20410/20111019 LMM31 ALL RIGHTS RESERVED MARMITEK TABLE OF CONTENTS TABLE OF CONTENTS... 2 SAFETY WARNINGS... 3 HOW DOES MARMITEK X-10 WORK?... 4 ADRESSES...

More information

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC) Applicant: Instrument type: 1. General requirements NOTE: Definitions are based on

More information

Australian Standard. Electricity metering equipment (ac) Particular requirements. Part 23: Static meters for reactive energy (classes 2 and 3)

Australian Standard. Electricity metering equipment (ac) Particular requirements. Part 23: Static meters for reactive energy (classes 2 and 3) AS 62053.23 2006 IEC 62053-23, Ed.1.0 (2003) AS 62053.23 2006 Australian Standard Electricity metering equipment (ac) Particular requirements Part 23: Static meters for reactive energy (classes 2 and 3)

More information

MODEL INFORMATION. AccuLoss MODELS ALMS 2100, ALMS 4100, ALMS 4200, ALMS 6200 & ALMS 4300

MODEL INFORMATION. AccuLoss MODELS ALMS 2100, ALMS 4100, ALMS 4200, ALMS 6200 & ALMS 4300 AccuLoss MODELS ALMS 2100, ALMS 4100, ALMS 4200, ALMS 6200 & ALMS 4300 The measurement of electric power and energy at high voltages and currents at low power factors is becoming increasingly important

More information

ERC Recommendation 54-01

ERC Recommendation 54-01 ERC Recommendation 54-01 Method of measuring the maximum frequency deviation of FM broadcast emissions in the band 87.5 to 108 MHz at monitoring stations Approved May 1998 Amended 13 February 2015 Amended

More information

Lighting Sciences, Inc.

Lighting Sciences, Inc. Lighting Sciences, Inc. Color and Photometric Testing, According to IESNA LM 79 Standards and Procedures, Test Report Files for: Par 30, 9W, DWF, Dimmable, 120V, Glass (SKU #180064) Seesmart 4139 Guardian

More information

The Effect of Changing the Applied Sequence Using the TVC on the Accuracy of the AC Signal Calibration

The Effect of Changing the Applied Sequence Using the TVC on the Accuracy of the AC Signal Calibration Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com The Effect of Changing the Sequence Using the TVC on the Accuracy of the AC Signal Calibration Rasha S. M. Ali National Institute for Standards

More information

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564.

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564. MODEL 66205 DIGITAL POWER METER MODEL 66205 The 66205 is the 2nd generation of the 66200 series power meter designed specifically for single channel measurement. Its state of art design is capable of providing

More information

DraftETSI EN V1.1.1 ( )

DraftETSI EN V1.1.1 ( ) Draft EN 301 893 V1.1.1 (2001-01) Candidate Harmonized European Standard (Telecommunications series) Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Harmonized EN covering essential requirements

More information

Installation and Operating Instructions

Installation and Operating Instructions Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2

More information

Commissioning and Maintenance of Power Factor Correction Systems

Commissioning and Maintenance of Power Factor Correction Systems Dear Customer, We would like to thank you for choosing a power factor correction system from FRAKO Kondensatoren- und Anlagenbau GmbH. It is a pleasure to welcome you into the ever-expanding circle of

More information

Gigabit Transmit Distortion Testing at UNH

Gigabit Transmit Distortion Testing at UNH Gigabit Transmit Distortion Testing at UNH Gig TX Distortion The purpose of the Gig TX distortion test is to make sure the DUT does not add so much distortion to the transmitted signal that the link partner's

More information

Report No: Test of: Securestyle Ltd Aluminium top and side hung windows And PVC-U top and side hung window. Tested to:

Report No: Test of: Securestyle Ltd Aluminium top and side hung windows And PVC-U top and side hung window. Tested to: Exova Warringtonapt Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com Report No: 191795 Test

More information

LED Driver Constant voltage

LED Driver Constant voltage Driver LCU 35W 12/24V IP20 EXC EXCITE indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to 50,000

More information

FORM 6-K GIGAMEDIA LIMITED

FORM 6-K GIGAMEDIA LIMITED UNITED STATES SECURITIES AND EXCHANGE COMMISSION Washington, D.C. 20549 FORM 6-K REPORT OF FOREIGN PRIVATE ISSUER PURSUANT TO RULE 13a-16 OR 15d-16 UNDER THE SECURITIES EXCHANGE ACT OF 1934 November 30,

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS CISPR 11:2011 IEC CISPR 11, Ed. 5.1 (2010) AS/NZS CISPR 11:2011 Australian/New Zealand Standard Industrial, scientific and medical equipment Radio-frequency disturbance characteristics Limits and

More information

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products IESNA SUSTAINING MEMBER Ref. No.: LCZP15060200 Dateof issue July 22,2015 Version 1.0 Total pages: 14 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State

More information

ETSI ES V1.2.1 ( )

ETSI ES V1.2.1 ( ) ES 201 235-2 V1.2.1 (2002-03) Standard Access and Terminals (AT); Specification of Dual-Tone Multi-Frequency (DTMF) Transmitters and Receivers; Part 2: Transmitters 2 ES 201 235-2 V1.2.1 (2002-03) Reference

More information

Method of measuring the maximum frequency deviation of FM broadcast emissions at monitoring stations. Recommendation ITU-R SM.

Method of measuring the maximum frequency deviation of FM broadcast emissions at monitoring stations. Recommendation ITU-R SM. Recommendation ITU-R SM.1268-4 (11/217) Method of measuring the maximum frequency deviation of FM broadcast emissions at monitoring stations SM Series Spectrum management ii Rec. ITU-R SM.1268-4 Foreword

More information

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C age 1 of 109 Report No.600332-04/01 TEST REORT Low-voltage switchgear and controlgear art 2: Circuit - breakers Report Reference No....: 600332-04/01 Tested by (name+signature)...:... Witnessed by (name+signature)...:...

More information

AGREEMENT on UnifiedPrinciples and Rules of Technical Regulation in the Republic of Belarus, Republic of Kazakhstan and the Russian Federation

AGREEMENT on UnifiedPrinciples and Rules of Technical Regulation in the Republic of Belarus, Republic of Kazakhstan and the Russian Federation AGREEMENT on UnifiedPrinciples and Rules of Technical Regulation in the Republic of Belarus, Republic of Kazakhstan and the Russian Federation The Republic of Belarus, Republic of Kazakhstan and the Russian

More information

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.: 10050333 001 Seite 2 von 19 Page 2 of 19 TEST SUMMARY 5.1 CONDUCTED EMISSION PER SECTION 15.107, FCC 47 CFR PART 15 SUBPART B RESULT: Pass 5.2 RADIATED EMISSION PER SECTION 15.109, FCC 47 CFR PART 15 SUBPART

More information

United Nations Development Programme

United Nations Development Programme Tax on Price Quotation Payment Terms (max. advanced payment is 20% of total price) must be inclusive of VAT and other applicable indirect taxes must be exclusive of VAT and other applicable indirect taxes

More information

Statement on variation of 900 MHz and 1800 MHz Wireless Telegraphy Act licences

Statement on variation of 900 MHz and 1800 MHz Wireless Telegraphy Act licences Statement on variation of 900 MHz and 1800 MHz Wireless Telegraphy Act licences Statement Publication date: 06 January 2011 Contents Section Page 1 Executive summary 1 2 Introduction 2 3 Assessment of

More information

LED Driver Constant voltage

LED Driver Constant voltage Driver LCU 100/96W 12/24V IP20 EXC EXCITE indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to

More information

TEST REPORT IEC Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy

TEST REPORT IEC Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy Test Report issued under the responsibility of: TEST REPORT Adjustable speed electrical power drive systems Part 5-1: Safety requirements Electrical, thermal and energy Report Reference No.... : 4787846262

More information

PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. :

PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. : Revision No. : 03 Page 1 of 5 1 Place where equipment to be supplied 1. CPRI, Hyderabad 2. CPRI, Bhopal 3. CPRI, Noida 4. EMC, Trivandrum 1 set at each location 2 Scope (supply / supply & Installation

More information

EU Standards dedicated Mobile and Base Station

EU Standards dedicated Mobile and Base Station EU Standards dedicated Mobile and Base Station Joe Wiart Whist Lab Orange Labs & Telecom Institute laboratory Convenor of the CENELEC TC106x WG1 Gaborone 2010 CENELEC Composed of the National Electrotechnical

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

Draft ETSI EN V1.1.1 ( )

Draft ETSI EN V1.1.1 ( ) Draft EN 302 245-1 V1.1.1 (2004-05) European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Transmitting equipment for the Digital Radio Mondiale (DRM)

More information

OPTOTRONIC OT 90/ /700 LT E 700mA Constant Current LED Power Supply with LEDset

OPTOTRONIC OT 90/ /700 LT E 700mA Constant Current LED Power Supply with LEDset data Reference: For LED modules: 350-700 ma LED Nominal Voltage: 220 240 V AC Line Current, nominal: 450mA @ 230V Mains Frequency: 50/60 Hz Output Current: 75-700 ma DC +/- 5% (350-700mA), see load diagramm

More information

Reliable SR technology for connected LED applications

Reliable SR technology for connected LED applications SR Bridge Datasheet Reliable SR technology for connected LED applications The SR Bridge can be used with existing DALI drivers to create an SR system. This is useful to connect e.g. multiple downlights

More information

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS. Model: VAC 50/60HZ.83A Max 100W Cat# 71542 100 Watts Trunion Mount RoHS UL/CUL TUV-CE QPL ID # PTX2Q1C3 Model: 71542 Input Voltage Input Current Input Power 100-277VAC 50/60HZ.83A Max 100W OVERALL LAMP PARAMETERS LED DRIVER LED Power

More information

EMC MEASUREMENT AND TEST REPORT

EMC MEASUREMENT AND TEST REPORT EN 55014-1:2006/A2:2011, EN 55014-2: 2015 EN 61000-3-2:2014, EN 61000-3-3: 2013 EMC MEASUREMENT AND TEST REPORT FOR Applicant: JINHUA SORIN ELECTRIC VEHICLE CO., LTD Address :NO.518 Meihe Road,Wucheng

More information

CONFORMANCE TEST REPORT FOR EN /-6

CONFORMANCE TEST REPORT FOR EN /-6 CONFORMANCE TEST REPORT FOR EN 301489-1/-6 Client: Product: Model: Manufacturer/supplier: Aztech Systems Limited DECT Phone H315-S1 (FP) Aztech Systems Limited Date test item received: 2006/05/09 Date

More information