Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter
|
|
- Prosper Rodgers
- 5 years ago
- Views:
Transcription
1 Features Regulated Converter Description Wide input range 85-5VAC Standby mode optimized (eco design Lot 6) High efficiency over the entire load range Operating temperature range: - C to + C Overvoltage and overcurrent protected EMC compliant without external components Encapsulated module with pins or wired The series are multipurpose 5 watt AC/DC power supplies for enhanced mains input conditions from VAC up to 5VAC with an extra wide operating temperature range from - C to + C. These modules are designed to supply worldwide applications in automation, Industry 4., IoT, household and smart buildings. For worldwide use they come with international safety certifications for industrial, domestic and ITE as well as household standards. With both PCB-mount and wired packages, fully protected outputs, and EMC class B emissions compliance without any external components, these are the easiest to use modular power solutions in the industry. 5 Watt Single Output Selection Guide Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ () Load (2) [VAC] [VDC] [ma] [%] [µf] RAC5-3.3SK/ RAC5-5SK/ RAC5-2SK/ RAC5-5SK/ RAC5-24SK/ Note: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load Model Numbering nom. Output Power Output Voltage RAC5- SK/277/W Note3: add suffix W for wired version without suffix, standard THT version Wired Single ERP compliant LOT6 E Ordering Examples: RAC5-5SK/277 5 Watt 5Vout Single Output THT version RAC5-24SK/277 5 Watt 24Vout Single Output THT version RAC5-5SK/277/W 5 Watt 5Vout Single Output Wired version RAC5-2SK/277/W 5 Watt 2Vout Single Output Wired version UL certified EN certified IEC/EN335- pending EN62233 pending EN532 compliant EN54-(-2) compliant CB Report REV.: 2/9 PA-
2 BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range (4,5) nom. Vin = 85VAC VDC Input Current Inrush Current No Load Power Consumption cold start at +25 C Input Frequency Range 47Hz 63Hz ErP Lot 6 Standby Mode Confirmity (Output Load Capability) Input Power=.5W.W Minimum Load % Power Factor Start-up Time Rise Time Hold-up Time..45. ms ms ms ms ms Internal Operating Frequency % load at nominal Vin khz Output Ripple and Noise (6) Note4: Note5: Note6: MHz BW 3.3, 5Vout others mvp-p % of Vout The products were submitted for safety files at AC-Input operation Refer to line derating graph on page PA-4 Measurements are made with a.µf MLCC & µf E-cap in parallel across output. (low ESR) 5VAC 4VDC ma ma 75mA 5A A 35A mw.34w.w Pi type Efficiency vs. Load Efficiency [%] RAC5-5SK/277 Efficiency [%] RAC5-2SK/277 REV.: 2/9 PA-2
3 REGULATIONS Parameter Condition Value Output Accuracy ±.% typ. Line Regulation low line to high line, full load ±.5% typ. Load Regulation (7) % to % load.% typ. Transient Response 25% load step change 4.% max. recovery time Note7: Operation below % load will not harm the converter, but specifications may not be met µs typ. Deviation vs. Load (at,, ) RAC5-5SK/277 RAC5-2SK/ Deviation [%] Deviation [%] PROTECTIONS Parameter Type Value Input Fuse (8) internal TA, slow blow Short Circuit Protection (SCP) below mw hiccup, automatic restart Over Voltage Protection (OVP) Over Voltage Category Over Current Protection (OCP) Class of Equipment 25% - 95%, latch of mode REV.: 2/9 PA-3 OVCII 25% - 95%, hiccup mode Isolation Voltage (safety certified) (9) minute 3kVAC I/P to O/P Isolation Resistance Isolation Voltage VDC GΩ min. Isolation Capacitance Insulation Grade Leakage Current Note8: Refer to local safety regulations if input over-current protection is also required Note9: For repeat Hi-Pot testing, reduce the time and/or the test voltage continued on next page Class II pf max. reinforced.25ma max.
4 Peak Load Capability Peak Load Calculation P nom = please refer to derating graph P P =.2 x P nom t s t 2 2 x t P r = P nom x (t + t 2 ) - P P x t t 2 P nom = nom. output power [W] P P = peak output power [W] P r = recovery power [W] t = peak time [s] t 2 = recovery time [s] Pout [%] P p P nom P r Practical Example: P r = 5W (s + s) - (6W x s) = 4.5W s t t 2 Time [s] ENVIRONMENTAL Parameter Condition Value Operating Temperature Range Maximum Case Temperature Temperature Coefficient Operating Altitude natural convection.m/s full load refer to derating graph 3.3Vout - C to + C 5, 2Vout - C to +75 C 5, 24Vout - C to + C 3.3Vout all others - C to +85 C - C to + C +95 C.5%/K Operating Humidity non-condensing 5% - 95% RH max. Pollution Degree Vibration according to MIL-STD-2G -Hz, 2G min./cycle, period min. each along x,y,z axis MTBF according to MIL-HDBK-27F, G.B. +25 C >4 x 3 hours Design Lifetime +25 C + C +25 C + C Note: Recognized by UL for safe operation up to m. High altitude operation may impact the performance and lifetime. Contact RECOM tech support for advice Derating Graph (@ Chamber and natural convection.m/s) Line Derating m PD2 25 x 3 hours 23 x 3 hours 5 x 3 hours 8 x 3 hours 3.3VDC 5, 2VDC 5, 24VDC Ambient Temperature [ C] Input Voltage [VAC] REV.: 2/9 PA-4
5 SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Audio/Video, information and communication technology equipment - Part : Safety requirements Audio/Video, information and communication technology equipment - Part : Safety requirements (CB Scheme) Audio/Video, information and communication technology equipment - Part : Safety requirements (LVD) Household and similar electrical appliances - Safety - Part : General requirements Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure RoHS2+ E498-A4-UL E498-A7-CB- UL62368-, 2nd Edition, 4-2- CAN/CSA-C22.2 No , 2nd Edt., 4-2 IEC62368-:4 2nd Edition EN62368-:4 + A:7 REV.: 2/9 PA-5 pending pending IEC335-: + A2:6 + C:6, 5th Edt. EN335-:2 + A:4 EN62233:8 RoHS-/65/EU + AM-5/863 EMC Compliance Conditions Standard / Criterion Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility Electromagnetic compatibility of multimedia equipment - Emission requirements () Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part : Emission EN64-3: 8, Class B EN532:5, Class B EN54-:6 + A2: Information technology equipment - Immunity characteristics - Limits and methods of measurement EN524: + A:5 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Air: ±2, 4, 8kV Contact: ±2, 4kV V/m, MHz-GHz 3V/m,.4GHz-2GHz V/m, 2GHz-2.7GHz EN54-2:5 EN-4-2: 9, Criteria B EN-4-3: 6 + A, 9, Criteria A Fast Transient and Burst Immunity AC and DC Port: ±2kV EN-4-4: 2, Criteria B Surge Immunity AC In Port (L-N): ±kv DC Output Port: ±.5kV EN-4-5: 4 +A:7, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields AC and DC Port: V EN-4-6: 4, Criteria A Power Magnetic Field Immunity Hz, A/m EN-4-8:, Criteria A Voltage Dips and Interruptions Voltage Dips: % Voltage Dips: % Voltage Dips: % Interruptions: >95% EN-4-:4 + A:7, Criteria C EN-4-:4 + A:7, Criteria C EN-4-:4 + A:7, Criteria B EN-4-: 4 + A:7,Criteria C Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=6A per phase EN-3-3: 3 Limitations on the amount of electromagnetic intererence allowed from digital and electronic devices Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to GHz DIMENSION AND PHYSICAL CHARACTERISTICS FCC 47 CFR Part 5 Supbart B, Class B ANSI C63.4-4, Class B Parameter Type Value Material case, baseplate potting PCB plastic, (UL94 V-) silicone, (UL94 V-) FR4, (UL94 V-) Dimension (LxWxH) THT/wired 3.7 x 26.7 x 2.8mm Weight Note: If output is connected to GND, please contact RECOM tech support for advice THT wired continued on next page 3.5g typ. 37.g typ.
6 Dimension Drawing THT (mm) 26.7 embossed logo / -.5 Ø. 4. ±. Recommended Footprint Details Pin Connections Pin # Single VAC in (N) 5 VAC in (L) 7 +Vout 9 -Vout Tolerance: xx.x= ±.8mm xx.xx= ±.25mm 5 Bottom View Top View Dimension Drawing Wired (mm) Ø2.7. ±. 5 ±2 Wired information # Function Wire color Type AWG VAC in (N) blue UL VAC in (L) brown UL Vout red UL Vout black UL Tolerance: xx.x= ±.8mm xx.xx= ±.25mm Bottom View 9 REV.: 2/9 PA-6
7 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) Packaging Quantity Storage Temperature Range THT wired THT wired tube tray 466. x.4 x 29.3mm 468. x 98. x 46.mm 2pcs 24pcs - C to +85 C Storage Humidity non-condensing % to % RH max. The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 2/9 PA-7
Features. Regulated Converter RAC Watt Single Output. AC/DC Converter
Features Regulated Converter Description Wide input range 8-64VAC Standby mode optimized PSU (ENER Lot 6) Ultra-high efficiency over entire load range Operating temperature range: -4 C to +8 C Class II
More informationFeatures. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter
Features Regulated Converter Unique, patent-pending design Isolated power supply with integrated mains filter Packaged inside of line filter case Safe, touchable DC outputs Easy installation Worldwide
More informationFeatures. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter
Features Regulated Converter Description 5W Class II power supply in compact 1 x 1 Package (high power density) Internal EMC class B filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical
More informationFeatures. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter
Features Regulated Converter Description Wide input range 85-35Vac Full load temperature range: -4 C to +65 C Ultra-high efficiency over entire load range No external components necessary International
More informationFeatures. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter
Features Regulated Converters 5W Class II Power Supply in Compact 1 x 1 Package (High Power Density) Internal EMC Class B Filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical Protection
More informationIEC/EN/UL60950 & CE certified, EN55032 Class B
Features Regulated Converter Universal input VAC 3W PCB mount package
More informationParameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption
Features Regulated Converter Universal input VAC 3W PCB mount package
More informationParameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption
Features Regulated Converter Universal input 85-35VAC 3W PCB mount package
More informationNote1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load
Features Regulated Converter Description 4mW max. no load power consumption High efficiency up to 76% Isolated output 3kVAC / 1 min SCP, OVP protection Wide operating temperature range: -4 C to +85 C Universal
More informationFeatures. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter
Features Regulated Converter Description 5mW max. no load power consumption Efficiency up to 76% Isolated output kvac / min SCP, OVP protection Wide operating temperature range: -4 C to +85 C Universal
More informationFeatures. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter
Features Regulated Converters Description Compact low profile AC-DC power supply mw no load power consumption Class II power supply with kvac isolation Universal input voltage range (~VAC) Low output ripple/noise
More informationFeatures. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter
Features Regulated Converter Description mw max. no load power consumption High efficiency up to 79% Isolated Output 3.75kVAC / 1 minute SCP, OVP protection Wide operating temperature range: -4 C to +
More informationFeatures. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter
Features Regulated Converter Description 35mW max. no load power consumption Efficiency up to 76% Isolated output 3kVAC / 1 minute SCP, OVP protection Wide operating temperature range: -4 C to +85 C Universal
More informationFeatures. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter
Features Switching Regulator Description Efficiency up to 96%, no need for heatsinks 2A continuous output current Vin up to 32V Vout: 1.2V - 15V Wide operating temperature - C to +7 C at full load Continuous
More informationEfficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.
Features Regulated Converter Universal Input VAC 3W PCB Mount Package
More informationHigh power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options
Features Unregulated Converters Description High power density 3W Converter in SIP7 case 3kVDC and 4kVDC Isolation Options Efficiency to 9% Certified to IEC/EN62368 The series of 3W high isolation DC/DC
More informationNotes: Note3: without suffix, standard isolation voltage (1kVDC/1 second) with suffix /H, high isolation voltage (3kVDC/1 second)
Features Unregulated Converters Description 1W Power In SMD Package Pin Compatible With R1S -4 C To +1 C Operating Temperature @ Full Load high 3kVDC/1 Second or 1kVDC/1 Second Isolation IEC/EN/UL62368-1
More informationPinning (3) 4:1 Input Single or Dual. Notes: Note3: /X2 is without ON/OFF CTRL and without Output Voltage Trimming
Features Regulated Converters 4:1 wide input voltage range Compact size 1 x1 package Efficiency up to % Wide operating temperature from - C to +75 C without derating Continuous short circuit protection
More informationPackaging. nom. Output Voltage
Features Unregulated Converters 1W Power in SMD package Pin compatible with R1S series -40 C to +100 C operating temperature @ full load High 3kVDC/1 second or 1kVDC/1 second isolation IEC/EN/UL62368-1
More informationFeatures. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter
Features Unregulated Converters Description 1W Power in SMD package Pin compatible with R1S/R1D series - C To + C Operating temperature @ full load High 3kVDC/1 second or 1kVDC/1 second isolation IEC/EN/UL62368-1
More informationFeatures. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter
Features Unregulated Converters Description 1W Power in SMD package Pin compatible with R1S/R1D series -4 C To +1 C Operating temperature @ full load High 3kVDC/1 second or 1kVDC/1 second isolation IEC/EN/UL62368
More informationFeatures. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.
Features Regulated Converter Long 5 year warranty 2MOPP/250VAC Suitable for built in Class II applications Wide input voltage range (85-264VAC) Low leakage current (
More informationNote1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)
Features Regulated Converter Long 5 year warranty 2MOPP/2VAC Suitable for built in Class II applications Wide input voltage range (85-264VAC) Low leakage current (
More informationFeatures. Unregulated Converters. 1 Watt SIP6 Micro Size, Single and Dual Output RBM. RBM- / Protection (3) Single or Dual.
Features Unregulated Converters Micro size SIP 6 package Industry standard pinout Power sharing on dual output version 3kVDC/1s basic isolation Optional continuous short circuit protection Efficiency up
More informationFeatures. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter
Features Regulated Converter Reinforced insulation for 250VAC working voltage Clearance and creepage distance: 8mm 5kVAC I/P to O/P 2MOPP isolation 2µA patient leakage current Industry standard pinout
More informationLoad (2) Single or Dual
Features Regulated Converter Reinforced insulation for 2VAC working voltage Clearance and creepage distance >8.mm 5kVAC I/P to O/P 2MOPP isolation 2µA patient leakage current Industry standard pinout 4:
More informationLoad (2) Single or Dual
Features Regulated Converter Reinforced insulation for VAC working voltage Clearance and creepage distance >8.mm kvac I/P to O/P 2MOPP isolation 2µA patient leakage current Industry standard pinout 4:
More informationFeatures. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.
Features Regulated Converters Description Long 5 Year Warranty 2MOPP/250VAC Suitable for built in Class II Applications Wide Input Voltage Range (85-264VAC) Low Leakage Current (
More information3kVDC or 4kVDC isolation Optional continuous short circuit protection UL94V-0 package material Efficiency up to 84% Suitable for IGBT applications
Features Unregulated Converters Description 3kVDC or 4kVDC isolation Optional continuous short circuit protection UL94V- package material Efficiency up to 84% Suitable for IGBT applications The RK and
More informationFeatures. Regulated Converters. RS6 6 Watt. SIP8 Single and Dual Output. DC/DC Converter. Description. Selection Guide
Features Regulated Converters Description Highest Power Density In SIP Package 1.6kVDC/1 Minute Isolation Efficiency Up To 88% -4 C To +75 C Operating Temperature Range @ Full Load EN695 And UL/EN62368-1
More informationFeatures. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter
Features Regulated Converter Description Reinforced insulation for 250VAC working voltage Clearance and creepage distance: 8mm 5kVAC I/P to O/P 2MOPP isolation 2µA patient leakage current Industry standard
More informationFeatures. Switching Regulator. 0.5 Amp SIP3 Single Output R R DC/DC Converter
Features Switching Regulator Description Efficiency up to 97%, no need for heatsinks Pin-out compatible with LM78XX linears Very low profile 4.75V - 32V Wide input range Short circuit protection, thermal
More informationFeatures. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.
Features Regulated Converters Description Long 5 Year Warranty 2MOPP/250VAC Suitable for built in Class II Applications Wide Input Voltage Range (85-264VAC) Low Leakage Current (
More informationOutput Current 1.2VDC 1.5VDC 1.5VDC 1.2VDC 1.5VDC 1.5VDC 0.65VDC. Vout=3.6VDC 180µA. Vout=1.8VDC, use E-cap 330µF Vout=3.3VDC and 3.6VDC.
Features Switching Regulator Description The is a DC/DC boost converter designed to run from single cell batteries. The input voltage range of.65v-3.3v means that alkaline, NiCd, NiMH, zinc-carbon or lithium
More informationFeatures. Regulated Converter. 5 Watt DIP24 Single Output. Rxx-B R - B. DC/DC Converter
Features Regulated Converter High output voltage DIP24 converter Adjustable output voltage up to VDC Cascadable for output voltages up to VDC 3kVDC input/output isolation Remote voltage programming by
More informationFeatures. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More informationFeatures. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More informationNotes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC
Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel
More informationFeatures. Switching Regulator. 0.5 Amp SIP3 Single Output R-78HB-0.5(L) DC/DC Converter
Features Switching Regulator Description Efficiency up to 96%, no heatsinks required Pin-out compatible with LM78XX linears Low profile (L/W/H=.5 x 8.5 x 7.5mm) High input voltage range, up to 7V Short
More informationNotes: Note1: Max. capacitive load is tested at nominal input voltage and full load. Single or Dual
Features Regulated Converters Description 6-Side Shielding External ON/OFF control 1.6kV Isolation UL/CSA/EN-695-1 Certified 2:1 Input Voltage Range Continuous Short Circuit Protection Efficiency up to
More information18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms
Features DIN Rail Description Universal AC Input (85264VAC) Protections: SCP, OVP, OLP, OTP DC OK Indicator LED with Relay Contacts 5% (8W) peak load capacity Builtin active PFC,PF>,95 High effciency up
More informationNotes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC
Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection
More informationFeatures. Switching Regulator. 0.5 Amp SIP3 Single Output R-78HB-0.5(L) R-78HB - /L. DC/DC Converter
Features Switching Regulator Description Efficiency up tpo 96%, no heatsinks required Pin-out compatible with LM78XX linears Low profile (L/W/H=.5 x 8.5 x 7.5mm) High input voltage range, up to 7V Short
More informationNote1: Measured at nominal input voltage and full load Note2: Measured at minimum input voltage and constant resistive load
Features Regulated Converters Description :1 wide input voltage range 1.kV isolation UL certified Efficiency up to 88% Fixed operating frequency Six-Sided continuous shield No minimum load required The
More informationNote1: Max. capacitive load is tested at nominal input and constant resistive load. RI3- _/_ Isolation (2) Single
Features Unregulated Converters 3 Watt in a SIP4 Package -3kVDC Isolation Efficiency up to 9% -4 C to + C Operating Temperature Range IEC/EN/UL69 (Pending) CB Report (Pending) Industry Standard Pinout
More information18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p
Features DIN Rail Universal AC Input (85) Protections: SCP, OVP, OLP, OTP DC OK Indicator LED with Relay Contacts 15% (18W) peak load capacity Builtin active PFC,PF>,95 High effciency up to 9.5% AC/DC
More information4.59A 2.36A 6.8A 13A 3.85W 2.85W ms 21ms. 31ms 100ms 48Vout 49ms 100ms. 240mVp-p 480mVp-p C 48Vout 480mVp-p
Features DI Rail Description Universal AC Input (85264VAC) Protections: SCP, OVP, OP, OTP DC OK Indicator ED with Relay Contacts 15% (72W) peak load capacity Builtin active PFC, PF>.95 High effciency up
More informationFeatures. Power Module. 2 Amp Single Output RBB RBB DC/DC Converter
Features Power Module 1W buck/boost converter with up to 4A output Input voltage can be higher, lower or same as output voltage >9% efficiency from 1mA 3mA load 7µA standby power consumption Low profile,
More informationFeatures. Non Isolated Power Module ROF-78E ROF-78E - SMD-R. DC/DC Converter
Features Low profile 4.mm Low cost Wide input range (5V - 36V) Short circuit protection Casellated connections Description The is a switching regulator with a wide input voltage range, high effi ciency
More informationNote1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.
Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Ribbed Case Style 22VDC Isolation Built-in EMC Filter, EN-522 Class B The RPP20 series
More informationFeatures. Switching Regulator. 2,3,4 Amp SIP12 Vertical & Horizontal Single Output. R-7xxxP_D. R-7 x. DC/DC Converter
Features Switching Regulator Description Non-isolated Synchronous rectification design Adjustable output voltage 2, 3, 4Amp adjustable positive step down Integrated switching regulator Over load protection
More informationNote1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.
Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Ribbed Case Style 22VDC Isolation Built-in EMC Filter, EN-522 Class B The RPP20 series
More informationFeatures. Switching Regulator. 1-2 Amp SIP12 Vertical & Horizontal Single Output. R-6xxxP_D. R-6 x. DC/DC Converter
Features Switching Regulator Description Non-isolated Adjustable output voltage 1-2AMP adjustable positive step down integrated switching regulator Internal short circuit protection ON/OFF control (ground
More informationTPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3
, Features High power density 40 W power supply (enclosed / open frame) 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3
More informationC B. Models. Models 2MOPP
AC/DC Medical Power Supplies High power density 3" x 5" open frame medical power supply 450 Watt with forced air cooling 320 Watt convection cooled without derating up to 50 C Medical certification to
More informationFeatures. Switching Regulator. 2,3,4,5 Amp SIP12 Vertical & Horizontal Single Output. R-5xxxPA_DA. R-5 xa. DC/DC Converter
Features Switching Regulator Description Non-isolated Synchronous rectification design Adjustable output voltage 2, 3, 4 & 5AMP adjustable positive step down integrated switching regulator Over load protection
More informationUL/ RAILWAYS Certified Constant Current LED Driver Wide Input and Output Voltage Range Digital PWM and Analogue Voltage Dimming
Features Regulated Converters Selection Guide UL/ RAILWAYS Certified Constant Current LED Driver Wide Input and Output Voltage Range Digital PWM and Analogue Voltage Dimming Short Circuit Protected Pinned
More informationDSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.
15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty
More informationMAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.
MAD40 MULTI -OUTPUT SERIES 2 X 3.5 Inch AC-DC POWER SUPPLIES UNIVERSAL INPUT RANGE UP TO 40Watts FEATURES 0.15 WATT LOW STANDBY POWER CONSUMPTION ULTRA LOW CROSS REGULATION UNDER 1.5 WIDE INPUT VOLTAGE
More informationVOF XX - XXX - X
date 01/31/018 page 1 of 10 SERIES: VOF-300 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 300W continuous power universal input voltage range industry standard 3 x 5 footprint power factor correction
More informationTMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.
TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins
More informationDSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details
120 Watts xxx Series Ultra Slim Design - 32 mm 150% Peak Load for 3 seconds Ambient Operation from -25 C to +70 C Full Load at 60 C (24V/48V) High Efficiency - Up to 92% Volt-Free Contact for OK Selectable
More informationOrdercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals
Features PCB Mounting with Solder Pins or Chassis Mounting with Screw Terminals Single, Dual and Triple Output Models Universal Input 8-2 VAC, 0 0 Hz EMI meets EN 022, Class B and FCC, Level B Low Ripple
More informationOutput Voltage* (nom.)(adjustable)
Industrial Power Supplies TIB Series, 80 480 W Slim profile, reduced module width High Power Factor up to 99% High efficiency up to 94% True back power immunity Low heat dissipation 150% peak current Automatic
More informationLCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans
LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis
More informationAdd suffix /W/X3 for wired version with both analogue and PWM dimming controls (six wires) (a)
Features Regulated Converters Selection Guide UL/ RAILWAYS Certified Constant Current LED Driver Wide Input and Output Voltage Range Digital PWM and Analogue Voltage Dimming Short Circuit and Overtemperature
More information500 ma DC-DC Step Down Converter P78G-Series
500 ma DC-DC Step Down Converter -Series Pin compatible to linear 78xx regulator (TO-220) Not isolated Efficiency up to 95 % Input voltage range up to 6 V Positive or negative output voltage possible Operating
More informationPower Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes
Features Trailing Edge AC Dimmable Constant Current Output High Efficiency (Up to 86%) Active Power Factor Correction (Up to 0.95) All-Around Protection: OVP, SCP and OLP Description The series operates
More informationOutput Full Load
SERIES DC-DC CONVERTER 2:1 & 4:1 WIDE INPUT RANGE UP TO 3.3 WATTS FEATURES REINFORCED INSULATION FOR 2VAC WORKING VOLTAGE CLEARANCE AND CREEPAGE DISTANCE :8.0mm/2MOPP 00VAC INPUT TO OUTPUT 2MOPP ISOLATION
More informationSeries AM50E-NZ 50 Watt DC-DC Converter
FEATURES: Wide Input range 2:1 Input to Output Isolation of 1500 High Efficiency up to 93% Input Over Voltage and Under Voltage Lockout Remote On/Off Control Output OVP, OCP & SCP Trim Adjustment Operating
More informationPART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom
Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE TAD 65 U B - xx yy - Series Name Output Input Output Output Output Output Output Protection
More informationOutput Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W
AEL15-80 Series 15-80 Watts Energy Efficiency Level V CEC 2008 and EISA 2007 Compliant Limited Power Source Approval China Compulsory Certification (CCC) Qualified +60 C Operating Temperature Compact Dimensions
More informationHEC-45LTN-45PFAS Rev A
A. Features High Efficiency (Up to 85%). Active Power Factor Correction (Typical 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP. Fully isolated plastic case with IP20 and dry location. Class
More informationFED30-48 S 05 - N HC Series Name Input Output Output Remote Control Assembly Option Voltage Quantity Voltage Option PART NUMBER STRUCTURE
Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE FED30-48 S 05 - N HC Series Name Input Output Output Remote Control Assembly Option
More informationVLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers
/40 Nominal Input Voltage 120/277 Vac, 220 to 240 Vac Max. Output Power Nominal Output Voltage Max. Output Current 12, 24, 48 Vdc 5, 2.5, 1.25 A Efficiency up to 90% typical Max. Case Temperature 90 C
More informationDoc. EA Model Number:
VPS-030AAC Series / VPS-030AAC 030AAC Highlights & Features VPS-030AAC05, 12, 15, 24 Meet DOE Level VI & ErP 2017 Low touch current. Suitable for type BF applications Detachable AC plug with multiple country
More informationDC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output
THN 20WI Series Application Note DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output Pending Applications Wireless
More informationRPP20-W. Features ICE Technology* POWERLINE+ 20 Watt 4:1 Single & Dual Output. DC/DC-Converter with 3 year Warranty
Features ICE Technology* Description 115 C Maximum Case Temperature -40 C Minimum Temp. UL Certified Built-in FCC/EN55022 Class B Filter 4:1 Wide Input Voltage Range Six Sided Shielded Enclosure Ribbed
More informationElectrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.
WLP120 Industrial Features 3 x 2 foot print Height 1 above PCB 120 Watts with Forced Air Cooling Efficiencies upto 93% -40 to 70 degree operating temperature Thermal Shut-Down feature >3.00m Hours, Telcordia-SR332-issue
More informationCB Scheme UL508 UL ATEX II3G
Industrial Power Supplies UL Hazloc Class I, division 2 approval and ATEX certification SEMI F47 compliant for voltage sag immunity Rugged metal case with optional side-mounting Very high efficiency up
More informationHEC-35LTA-XXTSAA Rev A
A. Features High Efficiency (Up to 87%). Active Power Factor Correction (Typical 0.95). Isolation Class II. All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated plastic case with IP20 and dry location.
More informationRPP30. Features ICE Technology* POWERLINE+ 30 Watt 2:1 Single & Dual Output. DC/DC-Converter with 3 year Warranty
Features ICE Technology* Description 115 C Maximum Case Temperature -40 C MinimumTemp. Built-in FCC/EN55022 Class B Filter 2:1 Wide Input Voltage Range Six Sided Shielded Enclosure Ribbed or Baseplate
More informationVIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION
060W-12 100W-24 Nominal Input Voltage 90 &, Efficient, CV Class 2 Max. Output Power Nominal Output Voltage Max. Output Current 120 & 277 Vac 12, 24 Vdc 5, 3.75 A Efficiency up to 90% typical Max. Case
More informationVGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION
Nominal Input Voltage Max. Output Power Nominal Output Voltage Max. Output Current 120/277 Vac 12, 24, Vdc 5, 3.92 A Efficiency up to 90% typical Max. Case Temperature 100 C (measured at the hot spot)
More informationM A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.
Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A D 65 U S 12 B - Application Package Dimension Output Input Output Output Protection
More informationEncapsulated Power Supply
0 Watt Features AC/DC Power Modules PCB Mounting or Chassis Mounting with Screw Terminals Fully encapsulated Plastic Case Single, Dual and Triple Output Models Universal Input 8- VAC, 7-0 Hz High Efficiency
More informationDN03S/D Series DC/DC CONVERTER 2-3W, DIP-Package
DN03S/D Series DC/DC CONVERTER 2-3W, DIP-Package FEATURES DIP-24 Plastic Package Wide 2:1 Input Range Operating Temp.Range -40 to +85 C Overload Protection No Minimum Load Requirement Isolation voltage
More informationFED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly Option Voltage Quantity Voltage Range Option
Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE FED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly
More informationHEC-30/35LTA-33TDAA Rev A
A. Features High Efficiency (Up to 86%). Active Power Factor Correction (Typical 0.95). Isolation Class II All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated metal case with IP20 and dry location. 1-10V,
More informationCLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby
; 12Vout @ 0.25A stdby Applications Industrial equipment LED Signage Telecommunications equipment Description Features Compact size 50.8mm x 101.6mm x 36.1mm (2in x 4in x 1.4in) with density of 18W/in
More informationDC/DC Converter VRA_YMD-6WR3 & VRB_YMD-6WR3 Series
6W isolated - converter in YMD package Wide input voltage and regulated dual/single output CB Patent Protection RoHS FEATURES Wide 2:1 input voltage range High efficiency up to 88% No-load power consumption
More informationMetal Case Power Supplies
, 120 480 Watt Features Compact U-bracket and enclosed power supplies Screw terminal block Very high efficiency up to 93 % No internal fan for 120 W & 240 W models. Universal input 90 264 VAC Adjustable
More information15 W DC/DC CONVERTERS. SERIES DESCRIPTION Page. PC15WR 2:1 Input Range 2 2 x 1 Metal Can Package 2kv Isolation
15 W DC/DC CONVERTERS SERIES DESCRIPTION Page PC15WR 2:1 Input Range 2 2 x 1 Metal Can Package 2kv Isolation PC15WR4 4:1 Input Range 6 2 x 1 Metal Can Package 2kv Isolation CTC TECHNOLOGY CO.,LTD. DC /
More informationEnvironmental. Electrical Specifications at 25 O C E Output Constant Current
LED Optimized Drivers 40 Watt - CONSTANT VOLTAGE OR CONSTANT CURRENT LED DRIVER WITH Model: Environmental 40W Drive Mode: Constant Current or Constant Voltage Technology: PFC Off-Line Switch Mode : 40W
More informationHEC-70LCN-350TDAF Rev B
A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Up to 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP Fully isolated metal case with IP20 and dry location. Class 2
More informationPART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1
Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A D 40 U S 12 B - Application Package Dimension Output Input Output Output Protection
More informationEnvironmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current
LED Optimized Drivers 40 Watt - CONSTANT VOLTAGE OR CONSTANT CURRENT LED DRIVER WITH Model: Environmental 40W Drive Mode: Constant Current or Constant Voltage Technology: PFC Off-Line Switch Mode : 40W
More informationMB120S 120W Single Output Medical Series
Features 2 x 4 x 1.25 Package, Ideal for 1U Applications 10-year Life design with Premium E-Caps 100 Watts convection cooled Class B Conducted and Radiated EMI performance BF Isolation Type Rated Designed
More informationEnvironmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current
LED Optimized Drivers 25 Watt - CONSTANT VOLTAGE OR CONSTANT CURRENT LED DRIVER WITH 25W Model: Environmental Drive Mode: Constant Current or Constant Voltage Technology: PFC Off-Line Switch Mode : 25W
More informationFor more information, please visit the product page. output. output current max (A)
date 12/12/217 page 1 of 1 SERIES: VMS-2 DESCRIPTION: AC-DC POWER SUPPLY FEATURES compact 2 x 4 high power-density design (CNF version is 2.4 x 4.6 ) universal input range efficiencies up to 93.5% 4th