1 Test report rev1.0 based on: ACP/WGB17/WP (Clauses B.1.2.2, B and B only) Frequency testing of VDL Mode 4 for the development of frequency planning criteria, October 2004, Version 1.4 VDL mode-4 Radio Communication Equipment Rockwell Collins VHF-2120

2 Report number: Contents MAIN MODULE INTRODUCTION PRODUCT TEST SCHEDULE OBSERVATIONS AND COMMENTS SUMMARY CONCLUSIONS...9 TEST RESULTS MODULE SQUELCH BREAK TEST (B.1.2.2) Test set up Squelch break test...11 Squelch break test (cont d) Squelch break test (cont d) SIGNAL TO PULSE (S/P) TEST (B.1.2.6) Test set up Signal to pulse (S/P) test Signal to pulse (S/P) test (cont d) Signal to pulse (S/P) test (cont d) BER TEST (DSB-AM INTERFERER TO VDL MODE 4 LINK) (B.1.3.2) Test set up BER test BER test (cont d) BER test (cont d) BER TEST (VDL MODE 4 INTERFERER TO VDL MODE 2 LINK) (B.1.3.2) Test setup...28 BER test BER TEST (VDL MODE 2 INTERFERER TO VDL MODE 4 LINK) (B.1.3.2) Test setup BER test BER TEST (VDL MODE 4 INTERFERER TO VDL MODE 4 LINK) (B.1.3.2) Test setup (RC VHF-2120 interferer to CNS VDL-4000 victim) Test setup (CNS VDL-4000 interferer to RC VHF-2120) BER test BER test (cont d)...38 USED TEST EQUIPMENT MODULE...40 PHOTOGRAPHS MODULE...41 REVISION HISTORY...56 This report comprises of five modules. The total number of pages is: 56

3 Page: 3 of 56 Main module Report number: Main module 1 Introduction This report contains the result of tests performed by: Telefication B.V. Edisonstraat 12a 6902 PK Zevenaar The Netherlands Telefication complies with the accreditation criteria for test laboratories as laid down in ISO/IEC 17025:2005. The accreditation covers the quality system of the laboratory as well as the specific activities as described in the authorized annex bearing the accreditation number L021 and is granted on 30 November 1990 by the Dutch Council For Accreditation (RvA: Raad voor Accreditatie). The copyright of this test report is owned by Telefication bv and may not be reproduced except in full without the written approval of Telefication B.V. Ordering party: Company name : Luftfartsverket Address : Vikboplan 11 Zipcode : SE City/town : Norrköping Country : Sweden Date of order : 13 March 2008

4 Page: 4 of 56 Main module Report number: Product A sample of the following product was submitted for testing: Product category : VDL mode-4 Radio Communication Equipment Manufacturer : Rockwell Collins USA Trade mark : Rockwell Collins Type designation : VHF-2120 Hardware version : Test model Software version : Test model Serial number : 277RF 3 Test schedule Tests are carried out in accordance with the specification detailed in chapter 5 "Summary" of this report. Tests were carried out at the following location: Rockwell-Collins France 6, avenue Didier Daurat Blagnac Cedex France Tests are carried out between the following dates: 14 January and 18 March 2008

5 Page: 5 of 56 Main module Report number: Observations and comments This report contains the results of tests of four different interferer to communication link configurations. 1. DSB-AM interferer to VDL mode 4 link.. Find below the information recorded for the labelling of each of the DSB -AM radio's radio which were used: Becker COMM 3200 system Serial number : LAB No. : /76 FTZ No : LB TSO : C37c, C38c RTCA : DO 156 CL.C RTCA : DO 157 CL.4 RTCA : DO 160A FCC ID : 8548RSAR3201 ED14A Rockwell Collins VHF-700A PRN : Serial number : TSO : C37b, C38b FCC ID : AJK9URPN DO-160-A : A2D2/JY Rockwell Collins VHF-2100E PRN : Serial number : 29PWD TSO : C128, C169 ETSO : 2C37e, 2C38e, 2C128 DO-160C : ENV CAT DO-178B : Level C/D 2. VDL mode 4 interferer to VDL mode 4 link This test was carried out by using two CNS Systems VDL4000 transceivers, one as the generator of the wanted signal and the other as the victim. The RC VHF-2120 was used to create the interferer.

6 Page: 6 of 56 Main module Report number: Find below the information recorded for the labelling of each of the CNS Systems VDL4000 radio's radio which were used: CNS Systems VDL4000 Serial number : 1025 PN : Software : SW This radio was used to send the wanted VDL4 signal. CNS Systems VDL4000 Serial number : 1047 PN : Software : SW This radio was used as the victim. The test was also carried out, by using a CNS VDL4000 radio as the interferer and the RC VHF as the victim. The communication link with the victim was established by a vector signal generator, type Agilent E4438C. RC VHF-2120 (victim) Serial number : 277RF PN : VDL mode 4 interferer to VDL mode 2 link This test was carried out, by using a VDL2 test bench containing a VHF-920 and a VHF-2100E transceiver, the first as the generator of the wanted signal and the second as the victim. The RC VHF-2120 was used to create the interferer. Rockwell Collins VHF-2100E (victim) PRN : Serial number : 29PWD TSO : C128, C169 ETSO : 2C37e, 2C38e, 2C128 DO-160C : ENV CAT DO-178B : Level C/D

7 Page: 7 of 56 Main module Report number: VDL mode 2 interferer to VDL mode 4 link This test was done, by using a RC VHF-2120 as an interferer and a RC VHF-2120 as a victim. The communication link with the victim was established by a vector signal generator, type Agilent E4438C. RC VHF-2120 (victim) Serial number : 277RF PN :

8 Page: 8 of 56 Main module Report number: Summary The product is intended for use in the following application area: AIRBORNE DIGITAL COMMUNICATION EQUIPMENT The sample is tested according to the following specification: ACP/WGB17/WP (Clauses B.1.2.2, B and B only) Frequency testing of VDL Mode 4 for the development of frequency planning criteria, October 2004, Version 1.4

9 Page: 9 of 56 Main module Report number: Conclusions The results of the test as stated in this report are exclusively applicable to the product item as identified in this report. Telefication bv does not accept any responsibility for the results stated in this report, with respect to the properties of product items not involved in these tests. All tests are performed by: name function : H.H. Lodewijk : Test Engineer Radio/EMC signature : Review of test methods and report by: name function : P.A. Suringa : Senior Engineer Radio/EMC signature : The above conclusions have been verified by the following signatory: date : 9 April 2008 name function : J.P. van de Poll : Co-ordinator Test Group signature :

10 Page: 10 of 56 Test results module 1 Squelch break test (B.1.2.2) 1.1 Test set up DUT VDL4 Tx Signal generator DSB-AM 1kHz, 30% Pwr attn Pwr attn + DSB-AM Rx Oscilloscope

11 Page: 11 of Squelch break test Measurement reference : Clause B Interferer : Rockwell Collins VHF-2120 Victim : Becker COMM 3200 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Result: Channel offset (N) db rel. to squelch open level 119 MHz 128 MHz 136 MHz -40 > 85 > 85 > > 85 > 85 > > 85 > 85 > 85-5 > 85 > 85 > 85-4 > 85 > 85 > 85-3 > 85 > 85 > 85-2 > 85 > 85 > (note 1) 0 (note 2) 0 (note 3) > 85 > 85 > > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > 85 note 1: corresponds to -92 dbm note 2: corresponds to -94 dbm note 3: corresponds to -96 dbm Channel offset: N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 2, 4, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

12 Page: 12 of Squelch break test (cont d) Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim : Rockwell Collins VHF-700A Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Result: Channel offset (N) db rel. to squelch open level 119 MHz 128 MHz 136 MHz -40 > 85 > 85 > > 85 > 85 > > 85 > 85 > 85-5 > 85 > 85 > 85-4 > 85 > 85 > 85-3 > 85 > 85 > 85-2 > 85 > 85 > 85-1 > 85 > 85 > (note) 0 (note) 0 (note) +1 > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > 85 note: corresponds to -107 dbm Channel offset: N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 2, 4, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

13 Page: 13 of Squelch break test (cont d) Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim : Rockwell Collins VHF-2100E Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Result: Channel offset (N) db rel. to squelch open level 119 MHz 127 MHz 136 MHz -40 > 85 > 85 > > 85 > 85 > > 85 > 85 > 85-5 > 85 > 85 > 85-4 > 85 > 85 > 85-3 > 85 > 85 > 85-2 > 85 > 85 > 85-1 > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > > 85 > 85 > 85 Channel offset: N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 2, 4, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

14 Page: 14 of 56 2 Signal to pulse (S/P) test (B.1.2.6) 2.1 Test set up DUT VDL4 Tx Signal generator DSB-AM 1kHz, 30% Pwr attn Pwr attn + DSB-AM Rx Oscilloscope

15 Page: 15 of Signal to pulse (S/P) test Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim : Becker COMM 3200 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input DSB-AM receiver under test Result: Channel offset (N) Becker COMM MHz 128 MHz 136 MHz Channel offset: N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 2, 4, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

16 Page: 16 of 56 VDL4 interferer to COMM [db] MHz 128MHz 136MHz Channel no

17 Page: 17 of Signal to pulse (S/P) test (cont d) Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim : Rockwell Collins VHF-700A Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input DSB-AM receiver under test Result: Channel offset (N) Rockwell Collins VHF-700A 119 MHz 128 MHz 136 MHz Channel offset: N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 2, 4, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

18 Page: 18 of 56 VDL4 interferer to RC-700A [db] MHz 128MHz 136MHz Channel no

19 Page: 19 of Signal to pulse (S/P) test (cont d) Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim ; Rockwell Collins VHF-2100E Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input DSB-AM receiver under test Result: Channel offset (N) Rockwell Collins VHF-2100E 119 MHz 128 MHz 136 MHz Channel offset: N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 2, 4, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

20 Page: 20 of 56 VDL4 interferer to VHF-2100E [db] MHz 128MHz 136MHz Channel no

21 Page: 21 of 56 3 BER test (DSB-AM interferer to VDL mode 4 link) (B.1.3.2) 3.1 Test set up DSB-AM E4438C inter Vector signal generator DSB-AM Tx Pwr attn Pwr attn + DUT VDL4 Rx

22 Page: 22 of BER test Measurement reference : clause B Interferer : Becker COMM 3200 Victim : Rockwell Collins VHF-2120 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input VDL4 receiver under test Result: db rel. (@ BER* ) 1%) to wanted signal of - 82 dbm Channel offset (N) 119 MHz 128 MHz 136 MHz * * ) Over bits Channel offset : N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 17. (The numbers listed refer to the module 'Used test equipment module'.)

23 Page: 23 of 56 COMM 3200 interferer to VDL [db] MHz 128MHz 136MHz Channel no

24 Page: 24 of BER test (cont d) Measurement reference : clause B Interferer : Rockwell Collins VHF-700A Victim : Rockwell Collins VHF-2120 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input VDL4 receiver under test Result: Channel offset (N) db rel. to wanted signal of - 82 dbm 119 MHz 128 MHz 136 MHz Channel offset : N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15. (The numbers listed refer to the module 'Used test equipment module'.)

25 Page: 25 of 56 VHF-700A interferer to VDL [db] MHz 128MHz 136MHz Channel no

26 Page: 26 of BER test (cont d) Measurement reference : clause B Interferer : Rockwell Collins VHF-2100E Victim : Rockwell Collins VHF-2120 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input VDL4 receiver under test Result: db rel. to wanted signal of - 82 dbm Channel offset (N) 119 MHz 128 MHz 136 MHz Channel offset : N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15. (The numbers listed refer to the module 'Used test equipment module'.)

27 Page: 27 of 56 VHF-2100E interferer to VDL [db] MHz 128MHz 136MHz Channel no

28 Page: 28 of 56 4 BER test (VDL mode 4 interferer to VDL mode 2 link) (B.1.3.2) 4.1 Test setup

29 Page: 29 of BER test Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim : Rockwell Collins VHF-2100E Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input VDL2 receiver under test Result: db rel. to wanted signal of - 82 dbm Channel offset (N) 119 MHz 128 MHz 136 MHz Channel offset : N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 3, 5, 6, 7, 8, 11, 12, 13, 14, 15, 16, 18. (The numbers listed refer to the module 'Used test equipment module'.)

30 Page: 30 of 56 VHF-2120 interferer to VDL [db] MHz 128MHz 136MHz Channel no

31 Page: 31 of 56 5 BER test (VDL mode 2 interferer to VDL mode 4 link) (B.1.3.2) 5.1 Test setup

32 Page: 32 of BER test Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim : Rockwell Collins VHF-2120 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input VDL4 receiver under test Channel loading : 75 msec burst per second Result: db rel. (@ BER* ) 1%) to wanted signal of - 82 dbm Channel offset (N) 119 MHz 128 MHz 136 MHz * ) Over bits Channel offset : N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 3, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

33 Page: 33 of 56 RC VHF-2120 interferer to RC VHF [db] MHz 128MHz 136MHz Channel no

34 Page: 34 of 56 6 BER test (VDL mode 4 interferer to VDL mode 4 link) (B.1.3.2) 6.1 Test setup (RC VHF-2120 interferer to CNS VDL-4000 victim)

35 Page: 35 of Test setup (CNS VDL-4000 interferer to RC VHF-2120)

36 Page: 36 of BER test Measurement reference : clause B Interferer : Rockwell Collins VHF-2120 Victim : CNS systems VDL4000 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input VDL4 receiver under test Result: db rel. to wanted signal of - 82 dbm Channel offset (N) 119 MHz 128 MHz 136 MHz * ) Over bits Channel offset : N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 3, 5, 6, 7, 8, 9, 11, 12, 13, 14, 15, 16 (The numbers listed refer to the module 'Used test equipment module'.)

37 Page: 37 of 56 VHF-2120 interferer to VDL [db] MHz 128MHz 136MHz Channel no

38 Page: 38 of BER test (cont d) Measurement reference : clause B Interferer : CNS systems VDL4000 Victim : Rockwell Collins VHF-2120 Atmospheric pressure : between 86 kpa and 106 kpa Temperature : 24 C Relative humidity : 46% Wanted signal level : -82 input VDL4 receiver under test Channel loading : 13 msec burst per second (1 slot) Result: db rel. (@ BER* ) 1%) to wanted signal of - 82 dbm Channel offset (N) 119 MHz 128 MHz 136 MHz Channel offset: N * 25 khz, at 136 MHz the +40 channel was tested at +39 ( MHz) Measurement uncertainty : +/- 1.6 db The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=1.96 providing a level of confidence of 95%, but excluding the effect of measurement system repeatability. Measurement equipment : 1, 3, 5, 6, 13, 14, 16 (The numbers listed refer to the module 'Used test equipment module'.)

39 Page: 39 of 56 CNS VDL-4000 interferer to RC VHF [db] MHz 128MHz 136MHz Channel no

40 Page: 40 of 56 Used test equipment module Report number: Used test equipment module Item Description Manufacturer Model ID 1 Spectrum analyser Hewlett Packard HP Digital Oscilloscope LeCroy LC334A Communication Service monitor Rhode & Schwarz CMS Vector signal generator Agilent E4438C SN = US DC Power supply Insek SPS RF attenuator 30 db / 25 watt 0-4 GHz Radial R No-01 7 RF attenuator 30 db / 25 watt 0-4 GHz 8 RF attenuator 30 db / 25 watt 0-4 GHz 9 RF attenuator 30 db / 25 watt 0-4 GHz 10 RF attenuator 30 db / 25 watt 0-1 GHz 11 RF attenuator 10 db / 25 watt 0-1 GHz 12 RF attenuator 10 db / 25 watt 0-1 GHz 13 Step attenuator 0-10 db 14 Step attenuator 0-70 db 15 Step attenuator 0-12 db Radial R No-02 Radial R No-03 Radial R No-04 Radial R No-05 Radial R No-06 Radial R No-07 ALAN 50V10-N ALAN 50V70-N Hewlett Packard 355C RF power splitter Mini circuits ZA2CS W-N 17 Power Attenuator 10W, 6 db, 50 Ω 18 VDL mode 2 test bench bench 4502 Radial R TE00486 Rockwell -Collins France -- --

41 Page: 41 of 56 Photographs module Report number: Photographs module Photograph 1: Rockwell-Collins VHF-2120, enclosure...42 Photograph 2: Rockwell-Collins VHF-2120, front...43 Photograph 3: Rockwell-Collins VHF-2120, label (top)...44 Photograph 4: Rockwell-Collins VHF-2120, label with serial number...45 Photograph 5: Rockwell-Collins VHF-920, front...46 Photograph 6: Rockwell-Collins VHF-920, label...47 Photograph 7: Rockwell-Collins VHF-700A, front...48 Photograph 8: Rockwell-Collins VHF-700A, label...49 Photograph 9: Becker COMM 3200, control unit...50 Photograph 10: Becker COMM 3200,...51 Photograph 11: CNS Systems, VDL 4000 (1), enclosure...52 Photograph 12: CNS Systems, VDL 4000 (1), label...53 Photograph 13: CNS Systems, VDL 4000 (2), enclosure...54 Photograph 14: CNS Systems, VDL 4000 (2), enclosure...55

42 Page: 42 of 56 Photographs module Report number: Photograph 1: Rockwell-Collins VHF-2120, enclosure

43 Page: 43 of 56 Photographs module Report number: Photograph 2: Rockwell-Collins VHF-2120, front

44 Page: 44 of 56 Photographs module Report number: Photograph 3: Rockwell-Collins VHF-2120, label (top)

45 Page: 45 of 56 Photographs module Report number: Photograph 4: Rockwell-Collins VHF-2120, label with serial number

46 Page: 46 of 56 Photographs module Report number: Photograph 5: Rockwell-Collins VHF-920, front

47 Page: 47 of 56 Photographs module Report number: Photograph 6: Rockwell-Collins VHF-920, label

48 Page: 48 of 56 Photographs module Report number: Photograph 7: Rockwell-Collins VHF-700A, front

49 Page: 49 of 56 Photographs module Report number: Photograph 8: Rockwell-Collins VHF-700A, label

50 Page: 50 of 56 Photographs module Report number: Photograph 9: Becker COMM 3200, control unit

51 Page: 51 of 56 Photographs module Report number: Photograph 10: Becker COMM 3200,

52 Page: 52 of 56 Photographs module Report number: Photograph 11: CNS Systems, VDL 4000 (1), enclosure

53 Page: 53 of 56 Photographs module Report number: Photograph 12: CNS Systems, VDL 4000 (1), label

54 Page: 54 of 56 Photographs module Report number: Photograph 13: CNS Systems, VDL 4000 (2), enclosure

55 Page: 55 of 56 Photographs module Report number: Photograph 14: CNS Systems, VDL 4000 (2), enclosure

56 Page: 56 of 56 Revision history Report number: Revision history REVISION DATE REMARKS Results of VDL mode 2 interferer to VDL mode 4 link added. Results of VDL mode 4 interferer to VDL mode 4 link extended.

Test Report

Test Report Test Report 20103677301 based on: IEC 61162-2 first edition 1998-09 (Clause 8.4.1 only) AIS Class A and Inland Transponder CNS Systems VDL 6000 Page: 2 of 31 Contents MAIN MODULE... 3 1 INTRODUCTION...

More information

Radio test report rev 2.0

Radio test report rev 2.0 Radio test report 20103677300 rev 2.0 based on: IEC 61993-2 First edition 2001 (Clause 15 only) AIS Class A and Inland Transponder CNS Systems VDL 6000 Report number:20103677300 rev 2.0 Contents MAIN MODULE...

More information

FCC Report for Parts ,

FCC Report for Parts , FCC Report for Parts 15.247, 15.7 Product name Applicant FCC ID : WSN Node : Evalan : 2AK2M-EVAWSN-N15 Test report No. : 1100161 Ver 1.00 Laboratory information Accreditation Telefication is designated

More information

Radio test report rev 2.0

Radio test report rev 2.0 Radio test report 20072231301 - rev 2.0 based on: - 47 CFR Part 15C, section 15.247 (01-OCT-06 Edition); - 47 CFR Part 15C, section 15.205 (01-OCT-06 Edition); - 47 CFR Part 15C, section 15.207 (01-OCT-06

More information

Radio test report Ver 1.00

Radio test report Ver 1.00 Radio test report 11413-Ver 1. based on: - FCC part 15; subpart C; section 15.249 & 15.9 (-1-13 edition) - FCC part 15, subpart B: section 15.9 (-1-13 edition) Base station Dyzle Y-Gate 3. GPRS/UMTS /

More information

Radar Burst at the End of the Channel Availability Check Time (continued) Results: 20 MHz Master

Radar Burst at the End of the Channel Availability Check Time (continued) Results: 20 MHz Master Radar Burst at the End of the Channel Availability Check Time (continued) Results: 20 MHz Master Limits: Part 15.407(h)(2)(ii) Plot showing the radar fired at the end of CAC A U-NII device shall check

More information

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Summit Data Communications Inc SDC-MSD30AG

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Summit Data Communications Inc SDC-MSD30AG TEST REPORT Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF FCC Part 15 Subpart E (UNII) Summit Data Communications Inc SDC-MSD30AG UPN: FCCID: COMPANY: TEST SITE: 6616A-SDCMSD30AG TWG-SDCMSD30AG

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: C-Track NX55 To: EN 300 440-1 V1.6.1 (2010-08) in accordance with EN 300 440-2 V1.4.1 (2010-08) Test Report Serial No.: RFI-RPT-RP84347JD02A This Test Report Is Issued

More information

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4 TEST REPORT Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4 COMPANY: TEST SITE: Xirrus 370 North Westlake Blvd., Suite 200 Westlake Village,

More information

Samsung Electro-Mechanics Co., LTD. 314, Maetan 3-Dong, Yeongtong-Gu Suwon City, Gyunggi-Do Korea. Transceiver

Samsung Electro-Mechanics Co., LTD. 314, Maetan 3-Dong, Yeongtong-Gu Suwon City, Gyunggi-Do Korea. Transceiver adio Test eport: 99493832 (part 2 of 2) Applicant: Samsung Electro-Mechanics Co., LT. 314, Maetan 3-ong, Yeongtong-Gu Suwon City, Gyunggi-o Korea Equipment Under Test: (E.U.T.) SL-2610U irect Sequence

More information

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD IC #: 4324A-BRCM1029 REPORT NUMBER: 07U11199-1C ISSUE DATE:

More information

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by  Project Number EMT08J027 Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary

More information

This report contains the test setups and data required by the FCC for equipment authorization in accordance with Title 47 parts 2, and 87.

This report contains the test setups and data required by the FCC for equipment authorization in accordance with Title 47 parts 2, and 87. FCC test report for the ADR-7050 Radio This report contains the test setups and data required by the FCC for equipment authorization in accordance with Title 47 parts 2, and 87. Prior to this FCC approval

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 HERMON LABORATORIES 68 Hatachana Street (Postal Mail to P.O. Box 23) Binyamina, 3055001, ISRAEL Mr. George Shleimovich Phone: 972 4

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII)

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) TEST REPORT Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF FCC Part 15 Subpart E (UNII) Intel Corporation Model(s): Centrino Advanced-N 6230 (62230ANHMW) COMPANY: TEST SITE: Intel Corporation

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3 Revision History Version Issue Date Revisions Rev. 01 July 04, 2014 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION... 3 1.1 Identification of the Testing Laboratory... 3 1.2 Identification of the

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed Seite 2 von 24 Page 2 of 24 TEST SUMMARY 5.1.1 FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed 5.1.2 99% BANDWIDTH RESULT: Passed 5.1.3 SPURIOUS EMISSION RESULT: Passed 5.2.1 SPURIOUS EMISSION RESULT: Passed

More information

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification Test Report: 4R08185.1 Applicant: Equipment Under Test: Nanoptix Inc. 699 Champlain Street Dieppe, New-Brunswick E4P 8L6 EZ-Tear FX Model Number: 102103 In Accordance With: FCC 47 CFR Part 15, Subpart

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 13725 SW Karl Braun Drive Beaverton, OR 97077 Andrew Mumford Phone: 503 627 2476 CALIBRATION Valid to: August 31, 2018

More information

Honeywell International, Inc.

Honeywell International, Inc. Honeywell International, Inc. ADDEDNUM TO EMC TEST REPORT 98388-8 Radar RDR-4000 Transmitter/Receiver (TR-1) Model: 930-2000-1E0 Tested to The Following Standards: FCC Part 2 / 87 Subpart F Date of issue:

More information

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification Test Report: 5R46150.1 Applicant: Equipment Under Test: Model Number: In Accordance With: Tested By: Nanoptix Inc. 699 Champlain Street Dieppe, New Brunswick E1A 1P6 Spill Proof Cuts SPC FCC 47 CFR Part

More information

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric Test Date(s): July 9 through July 19, 2010 UST Project Number: 10-0164 Summary Results for Product Description The Sample Under Test (SUT) is the. The SUT is a textile which is used as a protective shield

More information

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards: Itron, Inc. TEST REPORT FOR RF Telemetry Device Model: CCU100 Tested To The Following Standards: FCC Part 15 Subpart C Sections 15.247 and RSS 210 Issue 8 Date of issue: April 25, 2013 This test report

More information

Report On FCC ID: TA8AKRC IC: 287AB-AS PREPARED BY APPROVED BY DATED. 24 June 2016

Report On FCC ID: TA8AKRC IC: 287AB-AS PREPARED BY APPROVED BY DATED. 24 June 2016 Report On FCC and ISED Testing of the Ericsson KRC 161 489/1 (Radio 2203) WCDMA and LTE B2 & 25 (1900 MHz) Base Station In accordance with FCC CFR 47 Part 2, FCC CFR 47 Part 24, Industry Canada RSS- GEN

More information

Contact person Date Reference Page Tomas Lennhager P03968-MPE 1 (2) Electronics

Contact person Date Reference Page Tomas Lennhager P03968-MPE 1 (2) Electronics issued by an FCC listed Laboratory Reg. no. 93866. The test site complies with RSS-Gen, file no: IC 3482A Contact person Tomas Lennhager 2016-06-10 6P03968-MPE 1 (2) Electronics +46 10 516 54 09 Tomas.Lennhager@sp.se

More information

Rockwell Collins, Inc. VHF Users Manual

Rockwell Collins, Inc. VHF Users Manual Rockwell Collins, Inc. VHF-2200 Users Manual This manual provided to the FCC for product guidance, it should not be used by our OEM customers. Scope: This document will detail information required to install

More information

N : R2-E JDE :

N : R2-E JDE : TEST REPORT N : 821760-R2-E JDE : 133546 Subject Electromagnetic compatibility and Radio spectrum Matters (ERM) tests according to standards: EN 50364 (2010) EN 62369-1 (2009) Issued to Apparatus under

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: CIBS To: FCC Part 15.247: 2008 Subpart C, RSS-210 Issue 7 June 2007 & RSS-Gen Issue 2 June 2007 Test Report Serial No: RFI/RPT2/RP75103JD05A Supersedes Test Report

More information

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS1308-1809-W2E Customer Customer's representative In the capacity of Reference number

More information

VHF-422B X X X

VHF-422B X X X 3 8 9 7 :. 9 4 3-4 4 :8 3088,3/#0 43, $ 89028 ' ' 4 2 2 % 7, 3 8. 0 ; 0 7 3897:.9 43-44 70 5, 72, 3:, # #% $& %%! #% %# $ % 8 /4.:2039 2,.439, 3 31472,9 43 8:- 0.9 94 9 0 39073,9 43, %7,11. 3 728 349-0

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4 Revision History Version Issue Date Revisions Content Rev. 01 Nov. 08, 2017 Initial Issue Rev. 02 Dec. 05, 2017 Identified the actual channel number for testing in annex A. Added the filter information

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBL SERVICES LTD Partial Test of: BTM4 To: FCC Part 5.247: 08 Subpart C, RSS- Issue 7 June 07 & RSS-Gen Issue 2 June 07 Test Report Serial No: RFI/RPT/RP78JD03 This Test Report Is Issued Under

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBL SERVICES LTD Partial Test of: 5 To: FCC Part 5.247: 2008 Subpart C Test Report Serial No: RFI/RPT/RP79JD03 This Test Report Is Issued Under The uthority Of Brian Watson, Operations Director:

More information

AMEC s Statement on Panbo (2017/11/11)

AMEC s Statement on Panbo (2017/11/11) AMEC s Statement on Panbo (2017/11/11) Background Alltek Marine Electronics Corp (AMEC) with head office located in New Taipei City, Taiwan, is a provider of advanced AIS solutions, and supplies a full

More information

David Huang Checked By

David Huang Checked By RF TEST REPORT Report No.: Supersede Report No.: N/A Applicant ZTE Corporation Product Name LTE/WCDMA/GSM(EDGE GPRS) USB modem Model No. MF833V Serial No. N/A Test Standard FCC Part 22(H):2015, FCC Part

More information

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L FCC Test Report FCC ID Equipment Model No. Brand Name Applicant Address Standard : N7NHL7688 : Wireless Module : HL7688 : AirPrime : Sierra Wireless Inc. Received Date : Jul. 12, 2016 : 13811 Wireless

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Test of: Smart Gears Limited, Micro-tracker MT-01 To: 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP81827JD05A This test report is issued under

More information

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR 802.11g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD MODEL NUMBER: BCM94312HMGB REPORT NUMBER: 09U12439-2 ISSUE DATE:

More information

RF Test Report. Report No.: AGC EE13 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

RF Test Report. Report No.: AGC EE13 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO. Page 1 of 52 RF Test Report PRODUCT DESIGNATION BRAND NAME TEST MODEL CLIENT : Dual Band Mobile Radio : VGC : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.,LTD DATE OF

More information

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies Test Report Prepared for: Becker Avionics, Inc Model: TG660-50 Description: Aeronautical basestation radio used for emergencies Serial Number: 10001, 10002 FCC ID: 2AHX9TG660 To FCC Part 87 Date of Issue:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS 8203-J Piedmont Triad Parkway Greensboro, NC 27409 Gene Denmark Phone: 336 605 1665 Fax: 336

More information

TEST REPORT. For ELECTRONICS TECHNOLOGY (DONG GUAN) COMPANY LIMITED EN V9.0.2 ( )

TEST REPORT. For ELECTRONICS TECHNOLOGY (DONG GUAN) COMPANY LIMITED EN V9.0.2 ( ) TEST REPORT For ELECTRONICS TECHNOLOGY (DONG GUAN) COMPANY LIMITED No.161, Xin Min Road, Tong Luo Wei Industrial Zone, Jin Xia, Chang An Town, Dong Guan City, Guang Dong Province, China EN 301 511 V9.0.2

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head Office Science Park Eindhoven 5108, Gebouw 2 5692 EC Son en Breugel The Netherlands Location Abbreviation/ location Science Park Eindhoven

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ANRITSU COMPANY CALIBRATION SERVICES TX FACILITY 1155 East Collins Blvd. Richardson, TX 75081 Yeou-Song (Brian) Lee Phone: 408 201 1976

More information

Test report TRFWL. Lotek Wireless Inc. SRX800 SRX A-SRX800. RSS-215 Issue 2, June Date of issue: July 11, 2014.

Test report TRFWL. Lotek Wireless Inc. SRX800 SRX A-SRX800. RSS-215 Issue 2, June Date of issue: July 11, 2014. ONE WORLD OUR APPROVAL Test report 250123-2TRFWL Date of issue: July 11, 2014 Applicant: Lotek Wireless Inc. Product: SRX800 Model: SRX800 IC Registration number: 4272A-SRX800 Specification: RSS-215 Issue

More information

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators www.nemko.com Report Reference ID 167484-1TRFWL Test specification Title 47 - Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart

More information

This annex is valid from: to Replaces annex dated:

This annex is valid from: to Replaces annex dated: Premises: (Son) & Nijmegen LF 0 0 DC/LF Quantities LF 1 0 DC Voltage measuring and generating 10 V 5 10-7 U zenerreferences 1 V and 1.018 V 2.3 10-6 U zenerreferences 0 V to 10 V 0.3 V 10 V to 200 mv 3

More information

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. Test Of: Wood & Douglas Ltd ST500 Transmitter Test Report Serial No: RFI/EMCB2/RP39403B This Test Report supersedes RFI Test Report No.: RFI/EMCB1/RP39403B

More information

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna For : Motorola, Inc. 1301 East Algonquin Road Schaumburg, IL 60196 P.O. No. : 40335 Date Tested

More information

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT Prepared for MINASKA OUTDOORS 6517 PLATTE AVENUE LINCOLN, NEBRASKA 68507 Prepared by: KYLE FUJIMOTO

More information

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017 A Test Report # 317241 Equipment Under Test: RM024 Test Date(s): June 9 and June 21, 2017 Prepared for: Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI 53012 Report Issued by: Adam Alger,

More information

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No. Page 1 of 19 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER Equipment Under Test [EUT]: Model Number: Applicant: FCC ID : 1:6 Radio Control M5 Stuart Tank RC09037 21 st Century Toys

More information

Test Report. Nasjonal kommunikasjonsmyndighet Nygård 1, Postboks Lillesand, Norway

Test Report. Nasjonal kommunikasjonsmyndighet Nygård 1, Postboks Lillesand, Norway Report No. 305070-17 Test Report Product Name and address of the applicant Name and address of the distributor Model Rating Trademark DAB+ receiver Nasjonal kommunikasjonsmyndighet Nygård 1, Postboks 93

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: Ingenico France, IWL252-01T1535A To: 47CFR15.107, 47CFR15.109 and RSS-GEN Issue 3 December 2010 Test Report Serial No: RFI-EMC-RP82173JD02A V2.0 Version

More information

NXDN Signal and Interference Contour Requirements An Empirical Study

NXDN Signal and Interference Contour Requirements An Empirical Study NXDN Signal and Interference Contour Requirements An Empirical Study Icom America Engineering December 2007 Contents Introduction Results Analysis Appendix A. Test Equipment Appendix B. Test Methodology

More information

BE PREPARED FOR SIGFOX READY TM CERTIFICATION

BE PREPARED FOR SIGFOX READY TM CERTIFICATION May 18th 2018 BE PREPARED FOR SIGFOX READY TM CERTIFICATION Public use Revision History Revision Number Date Change description 0.1 August 15 th, 2017 Initial spec 0.2 May 18 th, 2018 CW test time Content

More information

Report On FCC ID: TA8AKRC IC: 287AB-AS PREPARED BY APPROVED BY DATED. 21 March 2017

Report On FCC ID: TA8AKRC IC: 287AB-AS PREPARED BY APPROVED BY DATED. 21 March 2017 Report On Ericsson Radio Unit GSM, WCDMA and LTE KRC 161 652/1 and KRC 161 652/2, Radio 2212 B5 (850 MHz), Base Station In accordance with FCC CFR 47 Part 2, FCC CFR 47 Part 22, Industry Canada RSS-GEN

More information

Test Report. Report Number: F161141E1. Equipment under Test (EUT): AIS Class B SO Transponder WideLink B600. Applicant:

Test Report. Report Number: F161141E1. Equipment under Test (EUT): AIS Class B SO Transponder WideLink B600. Applicant: Königswinkel 10 32825 Blomberg, Germany Phone: +49 (0) 52 35 / 95 00-0 Fax: +49 (0) 52 35 / 95 00-10 office@phoenix-testlab.de www.phoenix-testlab.de Test Report Report Number: F161141E1 Equipment under

More information

DFS Test Report. FCC & RSS-210, Issue 8. For. Model Name: A1427 Apple TV FCC ID: BCGA1427 IC ID: 579C-A1427

DFS Test Report. FCC & RSS-210, Issue 8. For. Model Name: A1427 Apple TV FCC ID: BCGA1427 IC ID: 579C-A1427 DFS Test Report FCC 15.407 & RSS-210, Issue 8 For Model Name: A1427 Apple TV FCC ID: BCGA1427 IC ID: 579C-A1427 TEST REPORT #: EMC_ APPLE_089_11001 _DFS DATE: 2011-01-31 FCC listed: A2LA accredited Bluetooth

More information

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No. Page 1 of 20 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER Equipment Under Test [EUT]: Model Number: Applicant: FCC ID : Radio Controlled Tank FH002 Zhongshan Fu Hai Electronics

More information

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob For Caterpillar Inc. 330 S.W. Adams Street Peoria, IL 61630 P.O. Number JBL 11260 Date Tested May 11, 2016 Test Personnel Mark Longinotti

More information

FCC PART 80 RADAR TEST REPORT

FCC PART 80 RADAR TEST REPORT 849 NW STATE ROAD 45 NEWBERRY, FL 32669 USA PH: 888.472.2424 OR 352.472.5500 FAX: 352.472.2030 EMAIL: INFO@TIMCOENGR.COM HTTP://WWW.TIMCOENGR.COM FCC PART 80 RADAR TEST REPORT APPLICANT ALPHATRON MARINE

More information

The equipment will provide up to 50W RF output power in the MHz band.

The equipment will provide up to 50W RF output power in the MHz band. 19 September 2007 FAA Spectrum Engineering Division 800 Independence Avenue SW Washington, DC 20591 Dear Mr. Frazier, Please be advised that we shall be making an application to the Federal Communications

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3 Revision History Version Issue Date Revisions Rev. 01 June 30, 2014 First edition TABLE OF CONTENTS 1 GENERAL INFORMATION... 3 1.1 Identification of the Testing Laboratory... 3 1.2 Identification of the

More information

R&TTE (1999/5/EC) Directive ETSI EN V1.8.1: 2012 TEST REPORT

R&TTE (1999/5/EC) Directive ETSI EN V1.8.1: 2012 TEST REPORT Page: 1 of 50 R&TTE (1999/5/EC) Directive ETSI EN 300 328 V1.8.1: 2012 TEST REPORT FOR Product Name: Brand Name: Model No.: Model Different: Report No.: TomTom GPS watch TomTom 8RS00 N/A EF/2013/20012-01

More information

Mobiwire SAS. September

Mobiwire SAS. September RF TEST REPORT Applicant FCCC ID Product Brand Model Report No. Issue Date Mobiwire SAS QPN-WANETAPLUS 4G Smartphone MobiWire, ALTICE MobiWire Waneta+, ALTICE S70 RXA1707-0218RF04R4 September 14, 2017

More information

Supplementary Information

Supplementary Information Supplementary Information Standards Laboratory Calibration Order 1-999999999-1 Model 8481A Manufacturer Agilent Technologies Description Power Sensor, 10 MHz to 18 GHz, -30 to +20 dbm Serial 2 Options

More information

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR 2.4GHz LE MODULE MODEL NUMBER: RN4020 REPORT NUMBER: 14U17191-1 ISSUE DATE: MARCH 21, 2014

More information

FCC Part 15C Compliance Test Report

FCC Part 15C Compliance Test Report Test Report no.: FCC15CNFC_RM-1045_19.docx Date of Report: 07-May-2014 Number of pages: 15 Customer s Tia Melava Contact person: Testing laboratory: FIN-33720 TAMPERE, FINLAND Customer: Nokia Corporation

More information

Deon Dai Engineer Reviewer

Deon Dai Engineer Reviewer EMC TEST REPORT Report No.: Supersede Report No.: N/A Applicant SAHAB TECHNOLOGY Product Name IP PHONE Main Model No. XT-23G Serial Model N/A Test Standard FCC Part 15 Subpart B Class B:2016, ANSI C63.4:

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Specialist Technical Committee

More information

Report On. FCC and Industry Canada Testing of the Inmarsat Global Ltd IsatPhone Pro GMR2+ Satellite Phone COMMERCIAL-IN-CONFIDENCE

Report On. FCC and Industry Canada Testing of the Inmarsat Global Ltd IsatPhone Pro GMR2+ Satellite Phone COMMERCIAL-IN-CONFIDENCE Report On FCC and Industry Canada Testing of the Inmarsat Global Ltd IsatPhone Pro GMR2+ Satellite Phone FCC ID: YCTISATPHONE IC ID: 8944A-ISATPHONE Document 75909459 Report 07 Issue 1 June 2010 TUV Product

More information

Document Report 01 Issue 2 Page 223 of 267

Document Report 01 Issue 2 Page 223 of 267 Channel Position B - Bandwidth 1.4 MHz - Antenna A Channel Position B - Bandwidth 1.4 MHz - Antenna A Document 75934860 Report 01 Issue 2 Page 223 of 267 Channel Position B - Bandwidth 15.0 MHz - Antenna

More information

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15. Page 1 of 51 Report No.: T1851663 01 TEST REPORT FCC ID: 2AGJ5WAP-30 Applicant Address : Gonsin Conference Equipment Co., Ltd : No.401-406,Block C, Idea Industry Park, No.41 Fengxiang Road, Shunde, Foshan,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ANRITSU COMPANY CALIBRATION SERVICES TX FACILITY 1155 East Collins Blvd. Richardson, TX 75081 Yeou-Song (Brian) Lee Phone: 408 201 1976

More information

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4-LB Test Specification: FCC PART 15, Subpart B ICES-003, Issue

More information

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947 EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947 7.1 RF Power -- Pursuant to 47 CFR 2.947(c) Method of Conducted Output Power Measurement: Adaptation of TIA/EIA-603-A clause 2.2.1 for Pulsed Measurements

More information

TRANSMITTER MODEL: KAS-2030M

TRANSMITTER MODEL: KAS-2030M Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved

More information

Proposal for ACP requirements

Proposal for ACP requirements AMCP WG D9-WP/13 Proposal for requirements Presented by the IATA member Prepared by F.J. Studenberg Rockwell-Collins SUMMARY The aim of this paper is to consider what level of is achievable by a VDL radio

More information

Tested To The. and. Report. We strive to TESTING

Tested To The. and. Report. We strive to TESTING Celadon Inc. TEST REPORT FOR Tessonics RF Remote, FGSK18 TES 01 Tested To The Following Standards: FCCC Part 15 Subpart C Sections 15.249 and RSS 210 Version 7 Report No.: 90470 21 Date of issue: June

More information

ITL Page 2 of 71 Report No.:

ITL Page 2 of 71 Report No.: ITL Page 1 of 71 Report No.: 12092752 TEST REPORT Applicant: Address of Applicant: Harman International Industries, Incorporated 8500 Balboa Blvd, Northridge, CA 91329, United States Manufacturer: Address

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report

More information

Software Configuration Control Test Report: 2.4 GHz WLAN

Software Configuration Control Test Report: 2.4 GHz WLAN Software Configuration Control Test Report: 2.4 GHz WLAN Test Report no.: FCCWLAN_KDB594280_RM- 1154_08.docx Date of Report: Number of pages: 13 Customer s Contact person: 11-Dec-2015 Juha Paukku Testing

More information

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No.

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No. Palstar, Inc. EMC TEST REPORT FOR HF LDMOS Amplifier Model: LA-1K Tested To The Following Standard: FCC Part 97 Subpart D Date of issue: November 28, 2017 This test report bears the accreditation symbol

More information

STC Test Report. Date : Page 1 of 13 No. : HM161169

STC Test Report. Date : Page 1 of 13 No. : HM161169 Date : 2009-05-11 Page 1 of 13 Applicant (ATS001): Atech Scientific Measurement Limited. Room A-C, 18 Floor, Luk Hop Ind. Bldg, 8 Luk Hop Street, Kowloon Manufacturer: Atech Scientific Measurement Limited.

More information

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG TEST REPORT Report Number: 100511823MIN-001 Rev 1.1 Project Number: G100511823 Testing performed on the 2102 IPG FCC ID: SVHBAROSTIMIPG1 Industry Canada ID: 9464A-IPG210A to 47 CFR Part 95 Subpart I:2013

More information

CE Radio Test Report

CE Radio Test Report CE Radio Test Report Report No. : ER172910A CE Radio Test Report APPLICANT : Quanta Computer Inc EQUIPMENT : Laptop Computer BRAND NAME : OLPC MODEL NAME : XO-1.75; XO-1.75HS STANDARD : ETSI EN 300 328

More information

ZTE. Applicant SRQ-Z-01K FCC ID. Product. Model. Issue Date. TA Technology. (Shanghai) Co., Ltd. compliance

ZTE. Applicant SRQ-Z-01K FCC ID. Product. Model. Issue Date. TA Technology. (Shanghai) Co., Ltd. compliance RF TEST REPORT Applicant FCC ID Product ZTE Corporation SRQ-Z-01K LTE/WCDMA/GSM Multi-Mode Digital Mobile Phone Model Z-01K Report No. RXC1708-0286RF13 Issue Date October 27, 2017 tested the above equipment

More information

EN RADIO Test REPORT

EN RADIO Test REPORT Page 1 of 53 EN 300 086 RADIO Test REPORT On Behalf of Zhengzhou Eshow Import and Export Trade Co., Ltd. Two way radio Model No.: RT-5RV Prepared for : Zhengzhou Eshow Import and Export Trade Co., Ltd.

More information

Certificate of Calibration

Certificate of Calibration Certificate of Calibration ISO/IEC 17025:2005 and ANSI/NCSL Z540.1-1994 Model Number Manufacturer Description Serial Number Customer Asset No. 11667A Keysight Technologies Inc DC-18 GHz power splitter,

More information

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland Version R3.03 09092003 TEST REPORT Date: ESPOO 05.10.2010 Page: 1 ( 10) Appendices - Number: 157439 No. 1 / 1 Date of handing in: 17.09.2010 Tested by: Timo Hietala, Test Engineer Reviewed by: Timo Leismala,

More information

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.: 10050333 001 Seite 2 von 19 Page 2 of 19 TEST SUMMARY 5.1 CONDUCTED EMISSION PER SECTION 15.107, FCC 47 CFR PART 15 SUBPART B RESULT: Pass 5.2 RADIATED EMISSION PER SECTION 15.109, FCC 47 CFR PART 15 SUBPART

More information

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards: Medtronic MiniMed TEST REPORT FOR GST3 Glucose Sensor Transmitter, MMT-7763A Tested To The Following Standards: FCC Part 15 Subpart C Sections 15.247 Date of issue: October 31, 2013 This test report bears

More information

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 www.nemko.com Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 Report Number: Product Marketing Name: 123766-1TRFEMC Paycheck 4 Thermal Ticket Printer Test Specification: FCC

More information

RIGOL Presents: New Solutions for Affordable Pre- Compliance Testing

RIGOL Presents: New Solutions for Affordable Pre- Compliance Testing Product Demo RIGOL Presents: New Solutions for Affordable Pre- Compliance Testing Wednesday, April 27, 2016 2:20 pm - 2:35 pm EDT Chris Armstrong Chris Armstrong is the Director of Product Marketing &

More information

FCC ID: 2ALT5-GW6088

FCC ID: 2ALT5-GW6088 TEST REPORT FCC ID: 2ALT5-GW6088 For GREAT WORLD LTD Electric Heater Model No. : GW-6078TBT, GW-6088TBT, GW-5088C-AMBT, GW-6088TMBT Trade Name : N/A Prepared for : Address : GREAT WORLD LTD 406 Room 1,

More information

FCC Test Report - LTE Band 26 (part 22)

FCC Test Report - LTE Band 26 (part 22) FCC Test Report - LTE Band 26 (part 22) Report ID : 03360-RF-00022 FCC ID : AZ489FT7078 Tested Model : LEX L10i Test Date : Nov 16, 2015 ~ Feb 25, 2016 Issued Date : 2 Mar, 2016 Applicant : Motorola Solution

More information

EMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM

EMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM EMC & Electrical Laboratory Page 1 of 5 Purpose: To maintain a list of equipment resources required per OEM test method. Responsibility: EMC technical manager, EMC lab technicians Method: EQUIPMENT DCX

More information

ICAO Handbook on Radio Frequency Spectrum Requirements for Civil Aviation Vol. I - ICAO Spectrum Strategy Vol. II - Frequency Planning

ICAO Handbook on Radio Frequency Spectrum Requirements for Civil Aviation Vol. I - ICAO Spectrum Strategy Vol. II - Frequency Planning ICAO Handbook on Radio Frequency Spectrum Requirements for Civil Aviation Vol. I - ICAO Spectrum Strategy Vol. II - Frequency Planning Aeronautical Spectrum Workshop Preparation for WRC-15 Cairo, Egypt,

More information