The Optimum Monitoring Location of Pressure in Water Distribution System

Size: px
Start display at page:

Download "The Optimum Monitoring Location of Pressure in Water Distribution System"

Transcription

1 water Article The Optimum Monitoring Location Pressure in Water Distribution System Sanghyun Jun 1 Hyuk Jae Kwon 2, * 1 Infra division, POSCO E&C, 241 Incheon tower daero, Incheon 22009, Korea; clays@poscoenc.com 2 Department Civil Engineering, Cheongju University, Chungbuk 28503, Korea * Correspondence: hjkwon@cju.ac.kr; Tel.: Received: 17 January 2019; Accepted: 10 February 2019; Published: 12 February 2019 Abstract: This study proposes two methods for determination optimum monitoring locations changes in a water distribution system. A sensitivity analysis method is used to calculate change in a junction due to change in dem at or junctions. A analysis method is used to calculate summation a junction due to change in dem at anor junction. These methods are applied to a small sample pipe network, pilot plant, small distribution system for verification. Furrmore, unsteady analysis sample pipe network an experiment in pilot plant are conducted to verify availability accuracy proposed methods. To verify methods, leakage at J-55 was artificially produced at pilot plant. The change was measured at five different combination groups sensor locations. From results, it was found that top ed group sensor locations, J-116, J-140, J-22, J-68, had highest s sensitivity. The results newly developed methods for determination monitoring locations are in good agreement with results unsteady Finally, proposed methods are applied to a real distribution system a small city as a test bed. It is found that proposed methods for determining monitoring locations changes in water distribution system are useful effective. Keywords: monitoring location; water distribution system; change; ; sensitivity 1. Introduction Real-time monitoring is important to detect leakage abnormal changes for efficient management water distribution systems. Water in a distribution system should be cautiously monitored since it is a very important matter for maintenance. An optimal determination method for monitoring locations is necessary because it is impossible to install gauges at every place in a water distribution system. From results furr development, it will be possible to take good care junctions that are more sensitive more contributive than or junctions, as determination method can detect abnormal changes leakage. Pudar Liggett [1] presented basic research developments about leakage sensing. They proposed that leakage detection problem can be solved by back-tracing method using gauges or flow meters. Leakage can be detected by a comparison between measurement according to changes in flow rate in orifice changes due to real leakage measurement. A sensitivity matrix can be used for determination monitoring locations. The sensitivity matrix showed that leakage amount location could be sensitively related to data size accuracy measurement. Water 2019, 11, 307; doi: /w

2 Water 2019, 11, Liggett Chen [2] proposed a monitoring method using unsteady reverse analysis in water distribution system. They used method characteristics for unsteady analysis also used time-lagged calculations. Misiunas et al. [3] proposed a method for breakage or leakage detection using unsteady They showed that leakage location can be detected by back-tracing velocity an unsteady wave. The size leakage could be estimated by unsteady wave particular shape wave due to a sudden break. Vitkovsky et al. [4] suggested inverse transient analysis method to estimate leakage location amount by unsteady wave. The shape unsteady wave is important for successive application inverse transient They conducted leakage experiments in laboratory to verify method. The experimental results showed that leakage amount was successfully estimated leakage location was correctly determined. Jun et al. [5] developed an algorithm to determine monitoring location based on effective index matrix a water distribution system. The installation gauges can be restricted as initial investigation can be exceeded. The proposed method estimated location online gauges by conducting a column search on effective index matrix. Moreover, method was applied to Cherry Hill distribution system to verify its efficiency. Cheong et al. [6] suggested a method to determine optimum location gauges using entropy ory. In ir study, entropy ory was applied to overcome shortcomings previous methods. For example, previous methods were difficult to apply for a specific area, which does not have systematic management, as se methods need to verify calibrate measured data. Furrmore, most previous works focused on determination junctions that can minimize measurement cost. In this study, two optimum determination methods gauge locations are proposed, namely sensitivity analysis Experiments were conducted to verify methods by measuring changes due to leakage in a real-size pilot plant. The relatively more sensitive monitoring locations according to changes due to leakage were selected compared with selected junctions from results sensitivity analysis The sensitivity analysis analyses can be used as determination methods for monitoring locations to detect leakage or abnormal situation in a water distribution system. These methods can be used to determine wher or where specific facility should be installed in water distribution system. 2. Determination Monitoring Location Figure 1 shows a sample pipe network with 15 pipes, 11 junctions, 1 distributing reservoir. Tables 1 2 show properties pipes dem at junctions. L is length pipe, J is junction, D is pipe diameter, C is Hazen-Williams coefficient. Q is dem at junction. Table 1. Pipe properties sample pipe network. Pipe L (m) D (cm) C Table 2. Dem at junctions. Junction Q (m 3 /s)

3 facility should be installed in water distribution system. 2. Determination Monitoring Location Figure 1 shows a sample pipe network with 15 pipes, 11 junctions, 1 distributing reservoir. Tables 1 2 show properties pipes dem at junctions. L is length pipe, J is junction, D is pipe diameter, C is Hazen-Williams coefficient. Q is dem at junction. Water 2019, 11, Figure 1. Sample pipe network. Figure 1. Sample pipe network Sensitivity Analysis According to Change in Hazen Williams Coefficient Firstly, head at junctions flow rate at pipes are estimated without any change in dem. Sensitivity analysis according to change in Hazen Williams coefficient is conducted to determine monitoring location for leakage detection. For example, steady analysis is conducted by changing Hazen Williams coefficient pipe 1 from 100 to 120. At same time, Hazen Williams coefficients or pipes are maintained as 100 original coefficient. Sensitivity analysis is conducted using following equation: S j = k h j /k (1) h j=1 j where k is number pipes, j is junction number, h j is original, h j is change at each junction due to change in Hazen Williams coefficient. Therefore, change due to change in Hazen Williams coefficient is summed up averaged by number pipes. The priority for junctions is estimated by sensitivity. Table 3 shows results sensitivity Table 3. Results sensitivity analysis according to change in Hazen Williams coefficient Junction Pressure Contribution Analysis According to Change in Dem The change at a junction due to change in dem can cause a change at anor junction. Therefore, at each junction can be quantitatively measured. In this study, is estimated by averaged change. The steady-state network analysis is conducted by creating an additional dem at a junction. At this point, original at each junction will change. The difference between ith junction jth junction divided by original at ith junction is averaged compared with each or. As shown in Equation (2), one junction to anor can be quantitatively estimated compared with each or. [ k ( ) ] hi h j C i = /k (2) j=1 where k is number pipes, i,j is junction number, h i is original head at i junction h j is head at j junction due to change in dem at i junction. h i

4 Water 2019, 11, h is original head at Water where 2019, k 11, is 307 number pipes, i, j is junction number, i 4 11 i junction h j is head at j junction due to change in dem at This i junction. equation This isequation used to estimate is used to how estimate how change at achange junction at a due junction to dem due to can dem affect can affect at anor at junction. anor The junction. steady-state The steady-state analysis is conducted analysis is by conducted changingby changing dem at each dem junction. at each Atjunction. this time, At analysis this time, results analysis suchresults as such as at each junction at each should junction be changed should as be changed dem as at dem specific at junction specific is changed. junction is Therefore, changed. Therefore, change at change j junction at according j junction toaccording sudden to change sudden in dem change at in dem i junction at to i junction originalto original at i junction at can be i junction summed can up be summed averaged up by averaged number by junctions; number this junctions; is called this is called i junction. The i junction. change The can be change estimated can at be each estimated time when at each time dem when at a junction dem is at changed. a junction Therefore, is changed. Therefore, number total number junctions total should junctions be should size be size matrix. The amount matrix. The change amount due change to dem due to is 0.02 dem m 3 /s is in 0.02 m sample 3 /s in pipe sample network. pipe network. Figure 2 shows Figure 2 flowchart shows for flowchart determination for determination monitoring locations monitoring using locations using Table 4 shows results Table 4 shows estimation. results The results show estimation. that The results show that J-10 was highest in sample pipe network. J-10 was highest in sample pipe network. Leakage simulation: produce leak at node i Analysis pipe network in steady state Calculate : No Is I = k? Yes Sort C i Determine monitoring location Figure 2. Flowchart for determination monitoring location using Table Table Results Results Junction Junction

5 Water 2019, 11, Pressure Sensitivity Analysis According to Change in Dem Pressure sensitivity analysis estimates change at a junction according to change in dem. The ratio change to original at each junction is summed up averaged by number junctions as sensitivity a junction. Therefore, number junctions should be size sensitivity matrix as steady-state analysis is conducted whenever dem conditions at each junction are changed. Pressure sensitivity, represented by Equation (3), is averaged differences ith junction due to change in dem. As shown in Equation (3), sensitivity each junction can be quantitatively estimated compared with each or. [ k ( ] hi h S i = i) /k (3) i=1 where k is number calculations, i is junction number, h i is original at i junction h i is changed at i junction according to change in dem at a specific junction. Table 5 shows results sensitivity analysis according to change in dem. Table 5. Results sensitivity analysis according to change in dem Junction h i Table 6 Equations (4) (5) can well explain sensitivity analysis The J-1 can be calculated by Equation (4) sensitivity J-1 is calculated by Equation (5). The number junctions is three number calculations is also three. [ ] (P1 A) + (P C 1 = 1 D) + (P 1 G) /3 (4) P 1 [ ] (P1 A) + (P S 1 = 1 B) + (P 1 C) /3 (5) P 1 Table 6. Examples at each junction according to simulation number. Simulation No. Pressure at J-1 Pressure at J-2 Pressure at J-3 0 P 1 P 2 P 3 1 A D G 2 B E H 3 C F I 3. Determination Monitoring Location Using Unsteady Analysis 3.1. Unsteady Analysis a Water Distribution System Unsteady analysis a pipe network shows flow rate at any location as a function time. Both continuity equation (Equation (6)) equation motion (Equation (7)) should be used in unsteady Although various methods were introduced to solve se two equations, results all methods were similar. The method characteristics [7 9] was selected for present study as it is numerically stable, accurate, convenient to use, has a short computation time. The equation motion continuity equation for method characteristics can be summarized as follows [9,10]: Q t + ga H x + f Q Q = 0 (6) 2DA

6 Water 2019, 11, c 2 Q ga x + H = 0 (7) t where Q represents flow rate, H is head, A is cross-sectional area pipe, c is speed wave, f is Darcy Weisbach friction coefficient. For present study, only friction loss is considered for head loss. Therefore, it is assumed that minor losses are negligible for present computations. Next, let us consider L 1 as equation motion L 2 as continuity equation. A linear combination equations, L = L 1 + λl 2 (where λ is Lagrangian multiplier) yields Equation (8). ( Q t ) ( Q H + λc2 + λga x t + 1 λ ) H + f Q Q = 0 (8) x 2DA It is noted that H = H(x, t) Q = Q(x, t). Thus, total derivatives may be written by chain rule as: dq dt = Q t + Q dx (9) x dt dh dt = H t + H dx x dt λ is defined by comparing Equation (8) with Equations (9) (10). In Equation (9), if dx dt is equal to λc 2, n first parensis Equation (8) is exactly same as Equation (9). In Equation (10), if dx dt is equal to λ 1, n second parensis Equation (8) is exactly same as Equation (10). Therefore, λ 1 = dx dt = λc2. λ = ± 1 c By using se equations, Equation (8) can be rewritten as: (10) (11) dq dt + ga c dh dt + f Q Q = 0 (12) 2DA dq dt ga c dh dt + f Q Q = 0 (13) 2DA Equation (12) is valid if dx dx dt = c. Furrmore, Equation (13) is valid if dt = c. The finite difference equations Equations (12) (13) can be written as follows: (Q n+1 i (Q n+1 i Q n i 1 ) + ga c (Hn+1 i Q n i+1 ) ga c (Hn+1 i H n i 1 ) + f t H n i+1 ) + f t 2DA Qn i 1 Qi 1 n 2DA Qn i+1 = 0 (14) Q n i+1 = 0 (15) where superscript n + 1 represents unknowns. The well-known stability convergence condition must be satisfied as: t x 1 (16) c In present study, c t/ x = 1 is used for stability condition for entire computation Results Unsteady Analysis Unsteady analysis was performed by method characteristics with assumption a sudden change in dem at each junction. It was assumed that an additional dem 0.02 m 3 /s occurred at each junction. At first calculation, it was assumed that a dem 0.02 m 3 /s suddenly occurred at J-1. Even though J-1 does not have dem, unsteady analysis was performed assuming that a dem abruptly occurred at J-1. At second calculation, unsteady analysis was performed assuming that an additional dem 0.02 m 3 /s occurred at J-2, which has a usual dem

7 Water 2019, 11, m 3 /s. The sensor location can be determined by sensitivity analysis for real leakage because a sudden additional dem can be considered as leakage at a specific junction. Table 7 shows change at each junction after unsteady A total 11 unsteady analyses were performed as shown in Table 7, as J-14 is considered as a reservoir neglected for calculation. Figure 3 shows oscillations at (a) J-7 (b) J-10. The analysis conditions t = s, x = 10 m, c = 1250 m/s (Courant Number = 1.0), Darcy Weisbach coefficient = were applied. As shown in figures, at J-10 responds more sensitively for change in dem. A change is defined as difference between maximum minimum due to a sudden change in dem. In Table 7, first row shows each junction next rows show change due to a sudden change in dem at each junction. The first column shows original piezometric head obtained from steady-state Piezometric Head (m) Table 7. Pressure change at each junction due to a sudden change in dem. No. J-2 (m) J-3 (m) J-4 (m) J-5 (m) J-6 (m) J-7 (m) J-8 (m) J-9 (m) J-10 (m) J-11 (m) J-12 (m) Water , 11, (a) (b) Figure 3. Pressure oscillations at (a) J-7 (b) J Determination Monitoring Location Using Using Results Unsteady Analysis Unsteady flow flow was was produced by by changing boundary condition by by introducing a sudden change in in dem. A sudden change in in dem can can cause a change that that can can be be observed at at any any place in in piping system. The The results unsteady analysis can can be be used for for determination monitoring locations. locations. Firstly, Firstly, height height due to due a sudden to a sudden change in change dem in should dem be should estimated. be The estimated. ratio The ratio height to height original to original at each junction at each is summed junction upis summed averaged up by averaged number by junctions number to compute junctions to compute sensitivity. In sensitivity. this study, sensitivity In this study, wassensitivity prescribedwas shown prescribed in Equation as shown (2) in Equation estimated. (2) Table estimated. 8 shows Table results 8 shows estimation results suggesting estimation top suggesting top sensor location. The first sensor location is determined as J-5, second is J-9, third is J-10. Table 9 shows results analysis using results unsteady As shown in Table 9, first sensor location is determined as J-9, second is J-5, third is J-12.

8 In this study, changes due to artificial leakage were measured at four arbitrary places. Water 2019, 11, sensor location. The first sensor location is determined as J-5, second is J-9, third is J-10. Table 9 shows results analysis using results unsteady As shown in Table 9, first sensor location is determined as J-9, second is J-5, third is J-12. Table 8. Results sensitivity analysis using results unsteady Junction Table 9. Results analysis using results unsteady Junction Applications to Pilot Plant Test Bed 4.1. Pilot Plant Figure 4 shows front view pilot plant. The pilot plant is constructed with one pump, 144 junctions, 179 cast iron pipes, which have same diameter 0.1 m. The length long side Water is 2019, approximately 11, m Figure 4. Front view pilot plant. Figure 4. Front view pilot plant. The proposed methods for determination monitoring locations were confirmed by unsteady The proposed It was proved methods that for methods determination are outsting monitoring because locations ir short were calculation confirmed time by unsteady simplicity. In this It was study, proved monitoring that methods location are in outsting pilot plant because was determined ir short by calculation time simplicity. analysis In this sensitivity study, analysis monitoring as shown location in Table in 10. The pilot first, plant second, was determined third ed by monitoring locations are analysis J-143, J-142, sensitivity J-141, analysis respectively. as shown However, in Table J-143, 10. The J-142, first, second, J-141 are third very ed last monitoring down streams locations are plant. J-143, Therefore, J-142, J-116 J-141, should respectively. be determined However, as J-143, top J-142, ed monitoring J-141 are location very last in down this pilot streams plant. plant. Therefore, J-116 should be determined as top ed monitoring location in this pilot plant. Table 10. monitoring location for pilot plant. Method Pressure Pressure sensitivity 1st 2nd 3rd 4th 5th 6th 7th 8th th

9 Water 2019, 11, Method 1st Table 10. monitoring location for pilot plant. 2nd 3rd 4th 5th 6th 7th 8th Pressure Pressure sensitivity th In this study, changes due to artificial leakage were measured at four arbitrary places. At first, monitoring location was determined by two methods. Pressure changes due to leakage were measured to confirm results monitoring location. Therefore, analysis sensitivity analysis were performed using measured change. From results analysis, first monitoring location was J-116, second, third, fourth were J-140, J-22, J-68, respectively. Therefore, first combination monitoring location is J-116, J-140, J-22, J-68. The leakage was produced at J-55 was measured at J-116, J-140, J-22, J-68. Five different combinations monitoring locations were used to measure at four different places. Figure 5 shows Combination 1 monitoring locations in pilot plant. The leakage point was fixed as J-55. Leakage amount was controlled by a valve at J-55 from m 3 /s to m 3 /s. Combination 1 is group top ed junctions such as J-116, J-140, J-22, J-68. The line upstream was maintained as 9 m (88,200 N/m 2 ). After fixing leakage location at J-55, five combinations four gauges measured changes according to artificial leakage. The nearest junctions to leakage location are J-68, J-27, J-70. Therefore, combinations are equally combined to avoid combination nearest junctions. Table 11 shows change in different combinations due to leakage at J-55. It is observed that Water 2019, 11, Combination 1 shows highest number for both sensitivity. Figure 5. Plan view pilot plant. Figure 5. Plan view pilot plant. Table 11. Results sensitivity measurement. Therefore, combinations are equally combined to avoid combination nearest junctions. Sensor Location for Pressure for Pressure Table Combination 11 shows Number (Junction change Number) in different combinations Sensitivity Analysis due to leakage Contribution at J-55. It is Analysis observed that Combination 1 shows highest number for both 1 22, 68, 116, sensitivity. 2 27, 70, 74, , 74, 114, Table 11. Results 27, 70, 114, 119 sensitivity 2 measurement. 3 5 Combination Number 68, 113, 134, 140 Sensor Location (Junction Number) 5 for Pressure Sensitivity Analysis 4 for Pressure Contribution Analysis 1 22, 68, 116, , 70, 74, , 74, 114, , 70, 114, , 113, 134,

10 Water 2019, 11, Therefore, combinations are equally combined to avoid combination nearest junctions. Table 11 shows change in different combinations due to leakage at J-55. It is observed that Combination 1 shows highest number for both sensitivity Test Bed A small block H city was selected for test bed as shown in Figure 6. In this area, 5000 people use this piping system, which contains 889 hydrants, 148 junctions, 162 pipes, 1 distributing reservoir. The house is a one- or two-story private house that has a rotop water tank. One distributing reservoir is only 15 m high in elevation supplies 802 m 3 /day ( m 3 /s) water. This pipe network consisted a 15-year old Polyvinyl Chloride (PVC) or Polyethylene (PE) pipe with a pipe diameter m. The length longest pipe is 298 m. Pressure analysis was conducted for test bed. Twenty-five junctions out 148 junctions were selected analyzed by changing dem at 25 junctions, as shown in Figure 6. The original dem at each 25th junction was changed by an additional dem m 3 /s. From results, it was found that top ed Water 2019, junction 11, 307 is J-138. As shown in Table 12, J-139, J-148, J-110, 11 J are second, third, fourth, fifth ed junctions, respectively. Figure 6. Small block pipe network test bed. Table 12. Figure Results 6. Small block pipe network analysis test for bed. test bed. Table 112. Results analysis 7 for 8 test 9bed. 10 Junction Junction Pressure analysis was conducted with same conditions analysis for test bed. From Pressure results, it was found analysis that was topconducted ed junction with same conditions analysis ratio isfor J-148. As test shown bed. From in Table 13, results, J-138, it J-139, was found J-110, that J-21 are top ed second, junction third, fourth, fifth ed junctions, ratio is J- respectively As shown Fromin Table results, 13, J-138, it was J-139, found J-110, that results J-21 are second, sensitivity third, analysis fourth, are similar fifth ed to results junctions, respectively. From results, it was found that results sensitivity analysis are similar to results Table 13. Results sensitivity analysis for test bed. Table 13. Results sensitivity analysis for test bed Junction Junction Conclusion In present study, two determination methods monitoring locations in a water distribution system were developed applied to a pilot plant a real test bed. The proposed methods were analysis sensitivity analysis, which were applied to pilot plant compared with experiments for verification. From results, it was found that top ed monitoring location was concentrated to downstream pilot plant piping system. Therefore,

11 Water 2019, 11, Conclusion In present study, two determination methods monitoring locations in a water distribution system were developed applied to a pilot plant a real test bed. The proposed methods were analysis sensitivity analysis, which were applied to pilot plant compared with experiments for verification. From results, it was found that top ed monitoring location was concentrated to downstream pilot plant piping system. Therefore, fourth, fifth, sixth, seventh ed monitoring locations, namely J-116, J-140, J-22, J-68, were chosen for monitoring location. To verify methods, leakage at J-55 was artificially produced at pilot plant. The change was measured at five different combination groups sensor locations. From results, it was found that top ed group sensor locations, J-116, J-140, J-22, J-68, had highest sensitivity. The analysis sensitivity analysis were applied to a small sample piping system. To verify two methods, unsteady analysis was conducted. The results proposed method were similar to results unsteady Finally, two methods were applied to a real distribution system a small city as a test bed. It was verified that newly developed methods monitoring locations were useful effective. These two methods can be applied to determine monitoring location to determine where a hydraulic device can be installed in a distribution system for operation management water supply system. For future study, two methods for monitoring location in a water distribution system will be tested by installing sensors in real water distribution system. Author Contributions: Conceptualization, H.J.K. S.J.; Methodology, H.J.K.; Investigation, H.J.K.; Writing Original Draft Preparation, H.J.K. S.J. Funding: This research received no external funding. Conflicts Interest: The authors declare no conflict interest. References 1. Pudar, P.S.; Liggett, J.A. Leaks in pipe networks. J. Hydraul. Eng. 1991, 118, [CrossRef] 2. Liggett, J.A.; Chen, L. Inverse transient analysis in pipe networks. J. Hydraul. Eng. 1994, 120, [CrossRef] 3. Misiunas, D.; Vitkovsky, J.; Olsson, G.; Simpson, A.; Lambert, M. Pipeline break detection using transient monitoring. J. Water Resour. Plan. Manag. 2005, 131, [CrossRef] 4. Vitkovsky, J.P.; Lambert, M.F.; Simpson, A.R.; Liggett, J.A. Experimental observation analysis inverse transients for pipeline leak detection. J. Water Resour. Plan. Manag. 2007, 133, [CrossRef] 5. Jun, H.D.; Cho, M.S.; Back, C.W.; Yoo, D.G.; Kim, J.H. A methodology to determine realtime monitoring locations for water distribution systems based on effect index matrix. In Proceedings KWAR Annual Conference, 22 May 2008; Korea Water Resources Association: Kyungju, Korea, 2008; pp Chung, G.H.; Chang, D.I.; Yoo, D.G.; Jun, H.D.; Kim, J.H. Determination Optimal Pressure Monitoring Locations for Water Distribution. J. Korea Water Resour. Assoc. 2009, 42, [CrossRef] 7. Chaudhry, H.M. Applied Hydraulic Transients; Springer: New York, NY, USA, Watters, G.W. Analysis Control Unsteady Flow in Pipe lines; Butterworths: Boston, MA, USA, Wylie, B.E.; Streeter, V.L. Fluid Transients in Systems; FEB Press: Ann Arbor, MI, USA, McInnis, D.; Karney, B.W. Transients in distribution networks: Field tests dem models. J. Hydraul. Eng. ASCE 1995, 121, [CrossRef] 2019 by authors. Licensee MDPI, Basel, Switzerl. This article is an open access article distributed under terms conditions Creative Commons Attribution (CC BY) license (

USING SYSTEM RESPONSE FUNCTIONS OF

USING SYSTEM RESPONSE FUNCTIONS OF USING SYSTEM RESPONSE FUNCTIONS OF LIQUID PIPELINES FOR LEAK AND BLOCKAGE DETECTION Pedro J. Lee " PhD Di,ssertation, 4th February, 2005 FACULTV OF ENGINEERING, COMPUTER AND MATHEMATICAL SCIENCES School

More information

Homework #3 Water Distribution Pipe Systems

Homework #3 Water Distribution Pipe Systems Page 1 of 7 CEE 371 Fall 009 Homework #3 Water istribution Pipe Systems 1. For the pipe system shown below (Figure 1), determine the length of a single equivalent pipe that has a diameter of 8 inches.

More information

Automated Leak Detection System for the Improvement of Water Network Management

Automated Leak Detection System for the Improvement of Water Network Management Proceedings Automated Leak Detection System for the Improvement of Water Network Management Domenico Perfido 1, *, Thomas Messervey 1, *, Chiara Zanotti 2, Massimiliano Raciti 1 and Andrea Costa 1 1 R2M

More information

Proceedings A Comb-Based Capacitive MEMS Microphone with High Signal-to-Noise Ratio: Modeling and Noise-Level Analysis

Proceedings A Comb-Based Capacitive MEMS Microphone with High Signal-to-Noise Ratio: Modeling and Noise-Level Analysis Proceedings A Comb-Based Capacitive MEMS Microphone with High Signal-to-Noise Ratio: Modeling and Noise-Level Analysis Sebastian Anzinger 1,2, *, Johannes Manz 1, Alfons Dehe 2 and Gabriele Schrag 1 1

More information

Non-Reflective Boundary Design via Remote Sensing and PID Control Valve

Non-Reflective Boundary Design via Remote Sensing and PID Control Valve Non-Reflective Boundary Design via Remote Sensing and PID Control Valve Katherine Qinfen Zhang 1, Bryan Karney 2 ASCE member, Stanislav Pejovic 3 Abstract: In this paper, Non-reflective (or semi-reflective

More information

Application Research on BP Neural Network PID Control of the Belt Conveyor

Application Research on BP Neural Network PID Control of the Belt Conveyor Application Research on BP Neural Network PID Control of the Belt Conveyor Pingyuan Xi 1, Yandong Song 2 1 School of Mechanical Engineering Huaihai Institute of Technology Lianyungang 222005, China 2 School

More information

DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS

DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS Jung-Taek Kim, Hyeonmin Kim, Wan Man Park Korea Atomic Energy Research Institute 145 Daedeok-daero, Yuseong-gu,

More information

Thermodynamic Modelling of Subsea Heat Exchangers

Thermodynamic Modelling of Subsea Heat Exchangers Thermodynamic Modelling of Subsea Heat Exchangers Kimberley Chieng Eric May, Zachary Aman School of Mechanical and Chemical Engineering Andrew Lee Steere CEED Client: Woodside Energy Limited Abstract The

More information

Quantification of Internal Air Leakage in Ball Valve using Acoustic Emission Signals

Quantification of Internal Air Leakage in Ball Valve using Acoustic Emission Signals 19 th World Conference on Non-Destructive Testing 2016 Quantification of Internal Air Leakage in Ball Valve using Acoustic Emission Signals Changhang XU 1, Guoxing HAN 1, Piao GONG 1, Lizhen ZHANG 1, Guoming

More information

COMPARATIVE STUDY OF PID AND FUZZY CONTROLLER ON EMBEDDED COMPUTER FOR WATER LEVEL CONTROL

COMPARATIVE STUDY OF PID AND FUZZY CONTROLLER ON EMBEDDED COMPUTER FOR WATER LEVEL CONTROL COMPARATIVE STUDY OF PID AND FUZZY CONTROLLER ON EMBEDDED COMPUTER FOR WATER LEVEL CONTROL A G Suresh 1, Jyothish Kumar S Y 2, Pradipkumar Dixit 3 1 Research scholar Jain university, Associate Prof of

More information

sensors ISSN

sensors ISSN Sensors 2008, 8, 7783-7791; DOI: 10.3390/s8127782 Article OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Field Calibration of Wind Direction Sensor to the True North and Its Application

More information

A Current Sensor-less Maximum Power Point Tracking Method for PV

A Current Sensor-less Maximum Power Point Tracking Method for PV A Current Sensor-less Maximum Power Point Tracking Method for PV System 1 Byunggyu Yu, 2 Ahmed G. Abo-Khalil 1, First Author, Corresponding Author Kongju National University, bgyuyu@kongju.ac.kr 2 Majmaah

More information

A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS

A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS R.Prabhu Jude, L.Sridevi, Dr.P.Kanagasabapathy Madras Institute Of Technology, Anna University, Chennai - 600 044. ABSTRACT This paper describes

More information

LEAKAGE DETECTION IN PIPELINES - THE CONCEPT OF SMART WATER SUPPLY SYSTEM

LEAKAGE DETECTION IN PIPELINES - THE CONCEPT OF SMART WATER SUPPLY SYSTEM 7th ECCOMAS Thematic Conference on Smart Structures and Materials SMART 2015 A.L. Araújo, C.A. Mota Soares, et al. (Editors) IDMEC 2015 LEAKAGE DETECTION IN PIPELINES - THE CONCEPT OF SMART WATER SUPPLY

More information

in Process Control System Presented by:

in Process Control System Presented by: Leakage Diagnosis in Process Control System Presented by: Haris M. Khalid Outline Problem Statement Leakage Diagnosis : A critical Issue A proposed Diagnostic Scheme Approaches Employed for Leakage Detection

More information

Experimental verification of the frequency response method of leak detection

Experimental verification of the frequency response method of leak detection Experimental verification of the frequency response method of leak detection by Lee, P.J., Lambert, M.F., Simpson, A.R. and Vítkovský, J.P. Journal of Hydraulic Research Citation: Lee, P.J., Lambert, M.F.,

More information

Drip System Simulation Programme (DSSP), Water Technology Centre, TNAU

Drip System Simulation Programme (DSSP), Water Technology Centre, TNAU DECISION SUPPORT SYSTEM FOR DESIGN OF DRIP SUBUNITS WITH TAPERED PIPES IN NON-UNIFORM SLOPES V.Ravikumar, Associate Professor, WTC, TNAU, Coimbatore Designing of drip irrigation system with desired uniformity

More information

Antenna Array Layout for the Localization of Partial Discharges in Open-Air Substations

Antenna Array Layout for the Localization of Partial Discharges in Open-Air Substations OPEN ACCESS Conference Proceedings Paper Sensors and Applications www.mdpi.com/journal/sensors Antenna Array Layout for the Localization of Partial Discharges in Open-Air Substations Guillermo Robles,

More information

CONTROLLER TUNING FOR NONLINEAR HOPPER PROCESS TANK A REAL TIME ANALYSIS

CONTROLLER TUNING FOR NONLINEAR HOPPER PROCESS TANK A REAL TIME ANALYSIS Journal of Engineering Science and Technology EURECA 2013 Special Issue August (2014) 59-67 School of Engineering, Taylor s University CONTROLLER TUNING FOR NONLINEAR HOPPER PROCESS TANK A REAL TIME ANALYSIS

More information

Comparison of Flow Characteristics at Rectangular and Trapezoidal Channel Junctions

Comparison of Flow Characteristics at Rectangular and Trapezoidal Channel Junctions Journal of Physics: Conference Series Comparison of Flow Characteristics at Rectangular and Channel Junctions To cite this article: Ajay Kumar Pandey and Rakesh Mishra 202 J. Phys.: Conf. Ser. 364 024

More information

Design Strategy for a Pipelined ADC Employing Digital Post-Correction

Design Strategy for a Pipelined ADC Employing Digital Post-Correction Design Strategy for a Pipelined ADC Employing Digital Post-Correction Pieter Harpe, Athon Zanikopoulos, Hans Hegt and Arthur van Roermund Technische Universiteit Eindhoven, Mixed-signal Microelectronics

More information

Scaled Laboratory Experiments of Shallow Water Acoustic Propagation

Scaled Laboratory Experiments of Shallow Water Acoustic Propagation Scaled Laboratory Experiments of Shallow Water Acoustic Propagation Panagiotis Papadakis, Michael Taroudakis FORTH/IACM, P.O.Box 1527, 711 10 Heraklion, Crete, Greece e-mail: taroud@iacm.forth.gr Patrick

More information

π/4 7π/4 Position ( µm)

π/4 7π/4 Position ( µm) Power Generation with Fundamental and Second-Harmonic Mode InP Gunn Oscillators - Performance Above 200 GHz and Upper Frequency Limits Ridha Kamoua 1 and Heribert Eisele 2 1 Department of Electrical and

More information

Design of an Intelligent Pressure Control System Based on the Fuzzy Self-tuning PID Controller

Design of an Intelligent Pressure Control System Based on the Fuzzy Self-tuning PID Controller Design of an Intelligent Pressure Control System Based on the Fuzzy Self-tuning PID Controller 1 Deepa S. Bhandare, 2 N. R.Kulkarni 1,2 Department of Electrical Engineering, Modern College of Engineering,

More information

Surveillance and Calibration Verification Using Autoassociative Neural Networks

Surveillance and Calibration Verification Using Autoassociative Neural Networks Surveillance and Calibration Verification Using Autoassociative Neural Networks Darryl J. Wrest, J. Wesley Hines, and Robert E. Uhrig* Department of Nuclear Engineering, University of Tennessee, Knoxville,

More information

Hydraulic Actuator Control Using an Multi-Purpose Electronic Interface Card

Hydraulic Actuator Control Using an Multi-Purpose Electronic Interface Card Hydraulic Actuator Control Using an Multi-Purpose Electronic Interface Card N. KORONEOS, G. DIKEAKOS, D. PAPACHRISTOS Department of Automation Technological Educational Institution of Halkida Psaxna 34400,

More information

ABSTRACT INTRODUCTION MATERIALS AND METHODS

ABSTRACT INTRODUCTION MATERIALS AND METHODS INTERNATIONAL JOURNAL OF AGRICULTURE & BIOLOGY 1560 8530/2007/09 1 59 63 http://www.fspublishers.org Design and Evaluation of Automatic Agricultural Land Leveling Control System for Scraper S.S. MOHTASEBI

More information

CHAPTER 4 IMPLEMENTATION OF ADALINE IN MATLAB

CHAPTER 4 IMPLEMENTATION OF ADALINE IN MATLAB 52 CHAPTER 4 IMPLEMENTATION OF ADALINE IN MATLAB 4.1 INTRODUCTION The ADALINE is implemented in MATLAB environment running on a PC. One hundred data samples are acquired from a single cycle of load current

More information

Electro-hydraulic Servo Valve Systems

Electro-hydraulic Servo Valve Systems Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org

More information

AUTOMATIC AND ADAPTIVE TUNING OF PID CONTROLLERS FOR PRESSURE REDUCING VALVES IN WATER SUPPLY SYSTEMS

AUTOMATIC AND ADAPTIVE TUNING OF PID CONTROLLERS FOR PRESSURE REDUCING VALVES IN WATER SUPPLY SYSTEMS AUTOMATIC AND ADAPTIVE TUNING OF PID CONTROLLERS FOR PRESSURE REDUCING VALVES IN WATER SUPPLY SYSTEMS Anderson Quadros André Murilo Universidade Federal de Pernambuco - UFPE anderson@compesa.com.br andre.murilo@ufpe.br

More information

Statistic evaluation of deviation between guaranteed and measured turbine efficiency

Statistic evaluation of deviation between guaranteed and measured turbine efficiency Statistic evaluation of deviation between guaranteed and measured turbine efficiency Petr Ševčík Hydro Power Group Leading Engineer OSC, a.s. Brno, Czech Republic Verification of Gibson method Discharge

More information

Implementation of decentralized active control of power transformer noise

Implementation of decentralized active control of power transformer noise Implementation of decentralized active control of power transformer noise P. Micheau, E. Leboucher, A. Berry G.A.U.S., Université de Sherbrooke, 25 boulevard de l Université,J1K 2R1, Québec, Canada Philippe.micheau@gme.usherb.ca

More information

An Improved Analytical Model for Efficiency Estimation in Design Optimization Studies of a Refrigerator Compressor

An Improved Analytical Model for Efficiency Estimation in Design Optimization Studies of a Refrigerator Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 An Improved Analytical Model for Efficiency Estimation in Design Optimization Studies

More information

CHAPTER 6 ANFIS BASED NEURO-FUZZY CONTROLLER

CHAPTER 6 ANFIS BASED NEURO-FUZZY CONTROLLER 143 CHAPTER 6 ANFIS BASED NEURO-FUZZY CONTROLLER 6.1 INTRODUCTION The quality of generated electricity in power system is dependent on the system output, which has to be of constant frequency and must

More information

Comparative Analysis Between Fuzzy and PID Control for Load Frequency Controlled Power

Comparative Analysis Between Fuzzy and PID Control for Load Frequency Controlled Power This work by IJARBEST is licensed under a Creative Commons Attribution 4.0 International License. Available at https://www.ij arbest.com Comparative Analysis Between Fuzzy and PID Control for Load Frequency

More information

6.334 Final Project Buck Converter

6.334 Final Project Buck Converter Nathan Monroe monroe@mit.edu 4/6/13 6.334 Final Project Buck Converter Design Input Filter Filter Capacitor - 40µF x 0µF Capstick CS6 film capacitors in parallel Filter Inductor - 10.08µH RM10/I-3F3-A630

More information

Robust Die Design with Spiral-shape Cavity

Robust Die Design with Spiral-shape Cavity Robust Die Design with Spiral-shape Cavity K.H. Jung, Y.B. Kim, Y.H. Kim, and G.A. Lee # Abstract Scroll compressors are used for air conditioning system in automobiles due to its relatively low pressure

More information

LIQUID SLOSHING IN FLEXIBLE CONTAINERS, PART 1: TUNING CONTAINER FLEXIBILITY FOR SLOSHING CONTROL

LIQUID SLOSHING IN FLEXIBLE CONTAINERS, PART 1: TUNING CONTAINER FLEXIBILITY FOR SLOSHING CONTROL Fifth International Conference on CFD in the Process Industries CSIRO, Melbourne, Australia 13-15 December 26 LIQUID SLOSHING IN FLEXIBLE CONTAINERS, PART 1: TUNING CONTAINER FLEXIBILITY FOR SLOSHING CONTROL

More information

Ultrasonic Guided Wave Testing of Cylindrical Bars

Ultrasonic Guided Wave Testing of Cylindrical Bars 18th World Conference on Nondestructive Testing, 16-2 April 212, Durban, South Africa Ultrasonic Guided Wave Testing of Cylindrical Bars Masanari Shoji, Takashi Sawada NTT Energy and Environment Systems

More information

USE OF WHITE NOISE IN TRACE/PARCS ANALYSIS OF ATWS WITH INSTABILITY

USE OF WHITE NOISE IN TRACE/PARCS ANALYSIS OF ATWS WITH INSTABILITY USE OF WHITE NOISE IN TRACE/PARCS ANALYSIS OF ATWS WITH INSTABILITY T. Zaki and P. Yarsky Nuclear Regulatory Commission Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission, MS CSB-3A07M,

More information

Open Access IMC-PID Controller and the Tuning Method in Pneumatic Control Valve Positioner

Open Access IMC-PID Controller and the Tuning Method in Pneumatic Control Valve Positioner Send Orders for Reprints to reprints@benthamscience.ae 1578 The Open Automation and Control Systems Journal, 2014, 6, 1578-1585 Open Access IMC-PID Controller and the Tuning Method in Pneumatic Control

More information

Distributed Frequency Control in Power Grids Under Limited Communication

Distributed Frequency Control in Power Grids Under Limited Communication 2016 IEEE 55th Conference on Decision and Control (CDC) ARIA Resort & Casino December 12-14, 2016, Las Vegas, USA Distributed Frequency Control in Power Grids Under Limited Communication Marzieh Parandehgheibi,

More information

-binary sensors and actuators (such as an on/off controller) are generally more reliable and less expensive

-binary sensors and actuators (such as an on/off controller) are generally more reliable and less expensive Process controls are necessary for designing safe and productive plants. A variety of process controls are used to manipulate processes, however the most simple and often most effective is the PID controller.

More information

Keywords: Leakage, frequency response, linear systems, transients, water pipelines, resonance. 1 Introduction

Keywords: Leakage, frequency response, linear systems, transients, water pipelines, resonance. 1 Introduction Journal of Hydraulic Research Vol. 44, No. 5 (2006), pp. 693 707 2006 International Association of Hydraulic Engineering and Research Experimental verification of the frequency response method for pipeline

More information

A NUMBER THEORY APPROACH TO PROBLEM REPRESENTATION AND SOLUTION

A NUMBER THEORY APPROACH TO PROBLEM REPRESENTATION AND SOLUTION Session 22 General Problem Solving A NUMBER THEORY APPROACH TO PROBLEM REPRESENTATION AND SOLUTION Stewart N, T. Shen Edward R. Jones Virginia Polytechnic Institute and State University Abstract A number

More information

Position Control of a Hydraulic Servo System using PID Control

Position Control of a Hydraulic Servo System using PID Control Position Control of a Hydraulic Servo System using PID Control ABSTRACT Dechrit Maneetham Mechatronics Engineering Program Rajamangala University of Technology Thanyaburi Pathumthani, THAIAND. (E-mail:Dechrit_m@hotmail.com)

More information

Hybrid LQG-Neural Controller for Inverted Pendulum System

Hybrid LQG-Neural Controller for Inverted Pendulum System Hybrid LQG-Neural Controller for Inverted Pendulum System E.S. Sazonov Department of Electrical and Computer Engineering Clarkson University Potsdam, NY 13699-570 USA P. Klinkhachorn and R. L. Klein Lane

More information

The Decision Aid Leak Notification System for Pigging False Alarm

The Decision Aid Leak Notification System for Pigging False Alarm ISBN 978-93-84468-94-1 International Conference on Education, Business and Management (ICEBM-2017) Bali (Indonesia) Jan. 8-9, 2017 The Decision Aid Leak Notification System for Pigging False Alarm Thanet

More information

Development of power transformer design and simulation methodology integrated in a software platform

Development of power transformer design and simulation methodology integrated in a software platform Development of power transformer design and simulation methodology integrated in a software platform Eleftherios I. Amoiralis 1*, Marina A. Tsili 2, Antonios G. Kladas 2 1 Department of Production Engineering

More information

VARIABLE STRUCTURE CONTROL DESIGN OF PROCESS PLANT BASED ON SLIDING MODE APPROACH

VARIABLE STRUCTURE CONTROL DESIGN OF PROCESS PLANT BASED ON SLIDING MODE APPROACH VARIABLE STRUCTURE CONTROL DESIGN OF PROCESS PLANT BASED ON SLIDING MODE APPROACH H. H. TAHIR, A. A. A. AL-RAWI MECHATRONICS DEPARTMENT, CONTROL AND MECHATRONICS RESEARCH CENTRE, ELECTRONICS SYSTEMS AND

More information

The issue of saturation in control systems using a model function with delay

The issue of saturation in control systems using a model function with delay The issue of saturation in control systems using a model function with delay Ing. Jaroslav Bušek Supervisor: Prof. Ing. Pavel Zítek, DrSc. Abstract This paper deals with the issue of input saturation of

More information

Permutation group and determinants. (Dated: September 19, 2018)

Permutation group and determinants. (Dated: September 19, 2018) Permutation group and determinants (Dated: September 19, 2018) 1 I. SYMMETRIES OF MANY-PARTICLE FUNCTIONS Since electrons are fermions, the electronic wave functions have to be antisymmetric. This chapter

More information

Applications of Computational Fluid Dynamics in Flow Measurement and Meter Design

Applications of Computational Fluid Dynamics in Flow Measurement and Meter Design Utah State University DigitalCommons@USU All Graduate Theses and Dissertations Graduate Studies 2016 Applications of Computational Fluid Dynamics in Flow Measurement and Meter Design Zachary B. Sharp Utah

More information

Smartphone Motion Mode Recognition

Smartphone Motion Mode Recognition proceedings Proceedings Smartphone Motion Mode Recognition Itzik Klein *, Yuval Solaz and Guy Ohayon Rafael, Advanced Defense Systems LTD., POB 2250, Haifa, 3102102 Israel; yuvalso@rafael.co.il (Y.S.);

More information

The sum of the currents entering a circuit junction is equal to the sum of the currents leaving the junction.

The sum of the currents entering a circuit junction is equal to the sum of the currents leaving the junction. By substituting the definition for resistance into the formula for conductance, the reciprocal formula for resistance in parallel circuits is obtained: In parallel circuits, there are junctions where two

More information

MICROWAVE SUB-SURFACE IMAGING TECHNOLOGY FOR DAMAGE DETECTION

MICROWAVE SUB-SURFACE IMAGING TECHNOLOGY FOR DAMAGE DETECTION MICROWAVE SUB-SURFACE IMAGING TECHNOLOGY FOR DAMAGE DETECTION By Yoo Jin Kim 1, Associate Member, ASCE, Luis Jofre 2, Franco De Flaviis 3, and Maria Q. Feng 4, Associate Member, ASCE Abstract: This paper

More information

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Design of Self-tuning PID controller using Fuzzy Logic for Level Process P D Aditya Karthik *1, J Supriyanka 2 *1, 2 Department

More information

र ष ट र य प र द य ग क स स थ न प द च च र

र ष ट र य प र द य ग क स स थ न प द च च र FIRST SEMESTER - (2014 Regulation) HM101 MA101 PH101 CH101 CE101 CS101 CC101 ME101 COMMUNICATION IN ENGLISH I MATHEMATICS I PHYSICS I CHEMISTRY I ENGINEERING MECHANICS BASICS OF PROGRAMMING ENERGY & ENVIRONMENTAL

More information

Calibration Procedure in Control Systems for Heating, Ventilating and Air Conditioning Systems: Prediction

Calibration Procedure in Control Systems for Heating, Ventilating and Air Conditioning Systems: Prediction Calibration Procedure in Control Systems for Heating, Ventilating and Air Conditioning Systems: Prediction Mohammad Miranbeigi Abstract Performance prediction is applicable to electric, electronic, and

More information

Research on Optical Fiber Flow Test Method With Non-Intrusion

Research on Optical Fiber Flow Test Method With Non-Intrusion PHOTONIC SENSORS / Vol. 4, No., 4: 3 36 Research on Optical Fiber Flow Test Method With Non-Intrusion Ying SHANG,*, Xiaohui LIU,, Chang WANG,, and Wenan ZHAO, Laser Research Institute of Shandong Academy

More information

Available online at ScienceDirect. Procedia Computer Science 56 (2015 )

Available online at  ScienceDirect. Procedia Computer Science 56 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Computer Science 56 (2015 ) 538 543 International Workshop on Communication for Humans, Agents, Robots, Machines and Sensors (HARMS 2015)

More information

Validation of the Experimental Setup for the Determination of Transmission Loss of Known Reactive Muffler Model by Using Finite Element Method

Validation of the Experimental Setup for the Determination of Transmission Loss of Known Reactive Muffler Model by Using Finite Element Method Validation of the Experimental Setup for the etermination of Transmission Loss of Known Reactive Muffler Model by Using Finite Element Method M.B. Jadhav, A. P. Bhattu Abstract: The expansion chamber is

More information

Characterization of Near-Ground Radio Propagation Channel for Wireless Sensor Network with Application in Smart Agriculture

Characterization of Near-Ground Radio Propagation Channel for Wireless Sensor Network with Application in Smart Agriculture Proceedings Characterization of Near-Ground Radio Propagation Channel for Wireless Sensor Network with Application in Smart Agriculture Hicham Klaina 1, *, Ana Alejos 1, Otman Aghzout 2 and Francisco Falcone

More information

MEASUREMENT AND INSTRUMENTATION QUESTION BANK UNIT I INTRODUCTION. Part A

MEASUREMENT AND INSTRUMENTATION QUESTION BANK UNIT I INTRODUCTION. Part A MEASUREMENT AND INSTRUMENTATION QUESTION BANK UNIT I INTRODUCTION Part A 1. Define Standard deviation. 2. Why calibration of instrument is important? 3. What are the different calibration methodologies?

More information

SET POINT TRACKING CAPABILITY ANALYSIS FOR AN INDUSTRIAL IPDT PROCESS MODEL

SET POINT TRACKING CAPABILITY ANALYSIS FOR AN INDUSTRIAL IPDT PROCESS MODEL Emerging Trends in Electrical, Electronics & Instrumentation Engineering: An international Journal (EEIEJ), Vol., No., August 24 SET POINT TRACKING CAPABILITY ANALYSIS FOR AN INDUSTRIAL IPDT PROCESS MODEL

More information

Rearrangement task realization by multiple mobile robots with efficient calculation of task constraints

Rearrangement task realization by multiple mobile robots with efficient calculation of task constraints 2007 IEEE International Conference on Robotics and Automation Roma, Italy, 10-14 April 2007 WeA1.2 Rearrangement task realization by multiple mobile robots with efficient calculation of task constraints

More information

Journal of Chemical and Pharmaceutical Research, 2015, 7(3): Research Article

Journal of Chemical and Pharmaceutical Research, 2015, 7(3): Research Article Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 215, 7(3):1243-1249 Research Article ISSN : 975-7384 CODEN(USA) : JCPRC5 Servo control system of electric cylinder based

More information

Generator type: Synchronous salient poles Vertical axis Nr. poles: 12 PD² rotor : kgm². Turbine elevation: m.a.s.l.

Generator type: Synchronous salient poles Vertical axis Nr. poles: 12 PD² rotor : kgm². Turbine elevation: m.a.s.l. Measurements with Pressure Time method by using different sections along the penstock for measuring the pressure for the flow calculation Fabio Fausto Muciaccia, Stefano Pasinato, Gianalberto Grego, Abstract:

More information

Application of Lean Six-Sigma Methodology to Reduce the Failure Rate of Valves at Oil Field

Application of Lean Six-Sigma Methodology to Reduce the Failure Rate of Valves at Oil Field , 22-24 October, 2014, San Francisco, USA Application of Lean Six-Sigma Methodology to Reduce the Failure Rate of Valves at Oil Field Abdulaziz A. Bubshait, Member, IAENG and Abdullah A. Al-Dosary Abstract

More information

A Searching Analyses for Best PID Tuning Method for CNC Servo Drive

A Searching Analyses for Best PID Tuning Method for CNC Servo Drive International Journal of Science and Engineering Investigations vol. 7, issue 76, May 2018 ISSN: 2251-8843 A Searching Analyses for Best PID Tuning Method for CNC Servo Drive Ferit Idrizi FMI-UP Prishtine,

More information

Dynamic Modeling of Air Cushion Vehicles

Dynamic Modeling of Air Cushion Vehicles Proceedings of IMECE 27 27 ASME International Mechanical Engineering Congress Seattle, Washington, November -5, 27 IMECE 27-4 Dynamic Modeling of Air Cushion Vehicles M Pollack / Applied Physical Sciences

More information

Leak detection in pipelines using cepstrum analysis

Leak detection in pipelines using cepstrum analysis INSTITUTE OFPHYSICS PUBLISHING Meas. Sci. Technol. 7 (26) 367 372 Leak detection in pipelines using cepstrum analysis MEASUREMENTSCIENCE AND TECHNOLOGY doi:.88/957-233/7/2/8 M Taghvaei, S B M Beck and

More information

A Compact Dual-Mode Wearable Antenna for Body-Centric Wireless Communications

A Compact Dual-Mode Wearable Antenna for Body-Centric Wireless Communications Electronics 2014, 3, 398-408; doi:10.3390/electronics3030398 OPEN ACCESS electronics ISSN 2079-9292 www.mdpi.com/journal/electronics Review A Compact Dual-Mode Wearable Antenna for Body-Centric Wireless

More information

2.5 Design of Channels

2.5 Design of Channels 2.6 Design of Open Channels Open channels have uses in urban stormwater drainage urban sanitary-sewer systems irrigation delivery systems In the next few lectures, we'll discuss the design procedure for

More information

API COPM CPMA Chapter 20.X

API COPM CPMA Chapter 20.X API COPM CPMA Chapter 20.X David Courtney Pamela Chacon Matt Zimmerman Dan Cutting 24 23 February 2017 Houston, TX Copyright 2017, Letton Hall Group. This paper was developed for the UPM Forum, 22 23 February

More information

Frequency f determined by the source of vibration; related to pitch of sound. Period T time taken for one complete vibrational cycle

Frequency f determined by the source of vibration; related to pitch of sound. Period T time taken for one complete vibrational cycle Unit 1: Waves Lesson: Sound Sound is a mechanical wave, a longitudinal wave, a pressure wave Periodic sound waves have: Frequency f determined by the source of vibration; related to pitch of sound Period

More information

The Influence of Antenna Positioning Errors on the Radio-Frequency Localization of Partial Discharge Sources

The Influence of Antenna Positioning Errors on the Radio-Frequency Localization of Partial Discharge Sources proceedings Proceedings The Influence of Antenna Positioning Errors on the Radio-Frequency Localization of Partial Discharge Sources José Manuel Fresno,, Guillermo Robles, Brian G. Stewart and Juan Manuel

More information

Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements

Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements Hasan CEYLAN and Gürsoy TURAN 2 Research and Teaching Assistant, Izmir Institute of Technology, Izmir,

More information

INVESTIGATION OF SLUG FLOW IN DEEPWATER ARCHITECTURES. Y. OLANIYAN TOTAL S.A. France

INVESTIGATION OF SLUG FLOW IN DEEPWATER ARCHITECTURES. Y. OLANIYAN TOTAL S.A. France INVESTIGATION OF SLUG FLOW IN DEEPWATER ARCHITECTURES Y. OLANIYAN TOTAL S.A. France CONTENTS Introduction Slug flow in field design phase Field case study Conclusion Investigation of Slug flow in Deepwater

More information

Open Access Design of Diesel Engine Adaptive Active Disturbance Rejection Speed Controller

Open Access Design of Diesel Engine Adaptive Active Disturbance Rejection Speed Controller Send Orders for Reprints to reprints@benthamscience.ae The Open Automation and Control Systems Journal, 05, 7, 49-433 49 Open Access Design of Diesel Engine Adaptive Active Disturbance Rejection Speed

More information

Multi-channel Active Control of Axial Cooling Fan Noise

Multi-channel Active Control of Axial Cooling Fan Noise The 2002 International Congress and Exposition on Noise Control Engineering Dearborn, MI, USA. August 19-21, 2002 Multi-channel Active Control of Axial Cooling Fan Noise Kent L. Gee and Scott D. Sommerfeldt

More information

FEM Approximation of Internal Combustion Chambers for Knock Investigations

FEM Approximation of Internal Combustion Chambers for Knock Investigations 2002-01-0237 FEM Approximation of Internal Combustion Chambers for Knock Investigations Copyright 2002 Society of Automotive Engineers, Inc. Sönke Carstens-Behrens, Mark Urlaub, and Johann F. Böhme Ruhr

More information

Hamming Codes as Error-Reducing Codes

Hamming Codes as Error-Reducing Codes Hamming Codes as Error-Reducing Codes William Rurik Arya Mazumdar Abstract Hamming codes are the first nontrivial family of error-correcting codes that can correct one error in a block of binary symbols.

More information

Displacement Measurement of Burr Arch-Truss Under Dynamic Loading Based on Image Processing Technology

Displacement Measurement of Burr Arch-Truss Under Dynamic Loading Based on Image Processing Technology 6 th International Conference on Advances in Experimental Structural Engineering 11 th International Workshop on Advanced Smart Materials and Smart Structures Technology August 1-2, 2015, University of

More information

Examples of Design for Cathodic Protection Systems

Examples of Design for Cathodic Protection Systems Examples of Design for Cathodic Protection Systems CURRENT REQUIREMENTS From Estimated Exposed Surface Area Estimating current requirements from expected exposed surface is always subject to error. There

More information

Experimental Investigation Of The Real Contact Arc Length Measurement In The Cylindrical Plunge Grinding

Experimental Investigation Of The Real Contact Arc Length Measurement In The Cylindrical Plunge Grinding Experimental Investigation Of The Real Contact Arc Length Measurement In The Cylindrical Plunge Grinding Jingzhu PANG 1, a *, Chongjun WU 1,,b, Beizhi LI 1,c, Yaqin ZHOU 1,d and Steven Y. LIANG,e 1 Donghua

More information

AN INSTRUMENTED FLIGHT TEST OF FLAPPING MICRO AIR VEHICLES USING A TRACKING SYSTEM

AN INSTRUMENTED FLIGHT TEST OF FLAPPING MICRO AIR VEHICLES USING A TRACKING SYSTEM 18 TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS AN INSTRUMENTED FLIGHT TEST OF FLAPPING MICRO AIR VEHICLES USING A TRACKING SYSTEM J. H. Kim 1*, C. Y. Park 1, S. M. Jun 1, G. Parker 2, K. J. Yoon

More information

Homeostasis Lighting Control System Using a Sensor Agent Robot

Homeostasis Lighting Control System Using a Sensor Agent Robot Intelligent Control and Automation, 2013, 4, 138-153 http://dx.doi.org/10.4236/ica.2013.42019 Published Online May 2013 (http://www.scirp.org/journal/ica) Homeostasis Lighting Control System Using a Sensor

More information

wprime TM Series 280W-CI ULTRASONIC WATER METER

wprime TM Series 280W-CI ULTRASONIC WATER METER MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-CI Spire Metering offers the latest in Commercial/Industrial ultrasonic metering technology for reliable flow measurement. The rugged 280W-CI water

More information

Low Power Approach for Fir Filter Using Modified Booth Multiprecision Multiplier

Low Power Approach for Fir Filter Using Modified Booth Multiprecision Multiplier Low Power Approach for Fir Filter Using Modified Booth Multiprecision Multiplier Gowridevi.B 1, Swamynathan.S.M 2, Gangadevi.B 3 1,2 Department of ECE, Kathir College of Engineering 3 Department of ECE,

More information

Slug wrenches - yes or no? Simple, efficient and cheap or simply not good enough?

Slug wrenches - yes or no? Simple, efficient and cheap or simply not good enough? Slug wrenches - yes or no? Simple, efficient and cheap or simply not good enough? Slug wrenches are common tools for joint assembly in high density pipe industries, such as the oil and gas, processing

More information

CHAPTER-4 FRUIT QUALITY GRADATION USING SHAPE, SIZE AND DEFECT ATTRIBUTES

CHAPTER-4 FRUIT QUALITY GRADATION USING SHAPE, SIZE AND DEFECT ATTRIBUTES CHAPTER-4 FRUIT QUALITY GRADATION USING SHAPE, SIZE AND DEFECT ATTRIBUTES In addition to colour based estimation of apple quality, various models have been suggested to estimate external attribute based

More information

New PID Tuning Rule Using ITAE Criteria

New PID Tuning Rule Using ITAE Criteria New PID Tuning Rule Using ITAE Criteria Ala Eldin Abdallah Awouda Department of Mechatronics and Robotics, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor, 83100, Malaysia rosbi@fke.utm.my

More information

Laboratory 1: Uncertainty Analysis

Laboratory 1: Uncertainty Analysis University of Alabama Department of Physics and Astronomy PH101 / LeClair May 26, 2014 Laboratory 1: Uncertainty Analysis Hypothesis: A statistical analysis including both mean and standard deviation can

More information

None Operational Amplifier (OPA) Based: Design of Analogous Bandgap Reference Voltage

None Operational Amplifier (OPA) Based: Design of Analogous Bandgap Reference Voltage Article None Operational Amplifier (OPA) Based: Design of Analogous Bandgap Reference Voltage Hao-Ping Chan 1 and Yu-Cherng Hung 2, * 1 Department of Electronic Engineering, National Chin-Yi University

More information

NTT DOCOMO Technical Journal. Method for Measuring Base Station Antenna Radiation Characteristics in Anechoic Chamber. 1.

NTT DOCOMO Technical Journal. Method for Measuring Base Station Antenna Radiation Characteristics in Anechoic Chamber. 1. Base Station Antenna Directivity Gain Method for Measuring Base Station Antenna Radiation Characteristics in Anechoic Chamber Base station antennas tend to be long compared to the wavelengths at which

More information

Durham Model Aquifer- Pumping test March 23, 2018

Durham Model Aquifer- Pumping test March 23, 2018 Durham Model Aquifer- Pumping test March 23, 2018 Analysis using MLU for Windows General setup A discussion in the LinkedIn group "Hydrogeology Forum" introduces the DMA pumping test. The aquifer is man-made

More information

Monitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity

Monitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity Monitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity Jamey Hilleary Director of M2M Products Elecsys Corporation Jerry Dewitt Senior Cathodic Protection Specialist

More information

Neural Network Adaptive Control for X-Y Position Platform with Uncertainty

Neural Network Adaptive Control for X-Y Position Platform with Uncertainty ELKOMNIKA, Vol., No., March 4, pp. 79 ~ 86 ISSN: 693-693, accredited A by DIKI, Decree No: 58/DIKI/Kep/3 DOI:.98/ELKOMNIKA.vi.59 79 Neural Networ Adaptive Control for X-Y Position Platform with Uncertainty

More information

Design of intermediate die shape of multistage profile drawing for linear motion guide

Design of intermediate die shape of multistage profile drawing for linear motion guide Journal of Mechanical Science and Technology 24 (12) (2010) 2539~2544 www.springerlink.com/content/1738-494x DOI 10.1007/s12206-010-0630-y Design of intermediate die shape of multistage profile drawing

More information