IECEx BVS X issue No. :3. Funkwerk Security Communications GmbH John-F. -Ken nedy-stral1e Salzgitter Germany
|
|
- Doris Nicholson
- 5 years ago
- Views:
Transcription
1 , INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit Certificate No.: Status: IECEx BVS.0099X issue No. :3 Current Page of 5 Certificate history: Issue No. 3 ( ) Issue No. 2 ( ) Issue No. ( ) Issue No. 0 (202--3) Applicant: Funkwerk Security Communications GmbH John-F. -Ken nedy-strale Salzgitter Germany Electrical Apparatus: Optional accessory: Radiotelephone type FT4 * Ex_ * C *** Type of Protection: Equipment protection by intrinsic safety "i" Marking: Ex ib I Mb Ex ib IIC T4 Gb Ex ib IIIC T25aC Db Approved for issue on behalf of the /ECEx Certification Body: Position: Signature: (for printed version) Date: H.-Ch. Simanski Head of Certification Body.'/!~ tg iz.ttj;j. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the OfficiaiiECEx Website. Certificate issued by: DEKRA EXAM GmbH Dinnendahlstrasse Bochum Germany J> DEKRA DEKRA EXAM GmbH
2 Certificate No.: IECEx BVS.0099X Issue No.: 3 Page 2 of 5 Manufacturer: Funkwerk Security Communications GmbH John-F.-Kennedy-Straf!.e Salzgitter Germany Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC : 20 Edition: 6.0 IEC : 20 Edition: 6.0 Explosive atmospheres - Part 0: General requirements Explosive atmospheres- Part : Equipment protection by intrinsic safety "i" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: DE/BVS/ExTR.030/03 Quality Assessment Report: DE/TU N/QAR /02
3 Certificate No.: IECEx BVS.0099X Issue No.: 3 Page 3 of 5 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: Subject and Type: Radiotelephone type FT4 * Ex_ a C *** series for 380 MHz- 430 MHz and the radiotelephone type FT4 * Ex_ c C *** series for 40 MHz- 470 MHz.! Instead of the *** in the complete denomination letters and numerals will be inserted which characterize modifications without relevance for explosion protection. Description Unchanged The radiotelephone must be used together with one of the following antennas according the used frequency band. The antennas will be changed only outside the potentially explosive atmospheres. Antenna type a FT 4, frequency range MHz (Part-No ) Antenna type b FT4, frequency range MHz (Part-No ) Antenna type ab FT4, frequency range MHz (Part-No ) Antenna type c FT4, frequency range MHz (Part-No ) I Together with the radiotelephone the following leather cases can be used: Open leather case (Part-No ) Leather case without access accessories (Part-No ) Leather case with access accessories (Part-No ) Leather case with access accessories and clip (Part.-No ) Together with the radiotelephone the following micro SO Card can be used: 2 GB (Part-No To be continued on page 4 CONDITIONS OF CERTIFICATION: YES as shown below: I The existing special conditions will remain and be suppleme nted by clause 9.. The radiotelephone with the battery should only be carried on the body of the user. 2. The battery can be changed in IIA-IIC applications. 3. In Group I and Group Ill (IIIA-IIIC) applications the battery may not be changed or separated from the radiotelephone. 4. The antenna can be connected or changed only outside the potentially explosive atmosphere. 5. When no accessory is connected, the side connector has to be covered by the side connector cap FT4 Ex C (Part-No ). 6. For detailed information about the side connector parameters refer to Funkwerk-sc document _02_ Attached approved accessory can be connected to the side connector only outside the potentially explosive atmosphere. 8. Attached approved accessories must fulfil the criteria of the radiotelephone and for the Group Ill (lila up to IIIC) it must fulfil the IP6X and for Group I it must fulfil the IP54 in accordance with IEC I,9. The micro SO Card (2GB, 4GB and 8GB) has to be changed or removed on ly outside the potentially explosive I atmosphere. l o. A belt clip type Clip FT4 Ex antistatic (Part-No ) can be changed only outside the potentially explosive atmosphere.. The Click fast stud FT 4 Ex instead of the belt clip type Clip FT 4 Ex can be changed or removed only outside the potentially explosive atmosphere. ' 2. With respect to the warning against potential electrostatic hazard, read and follow the instructions. (See safety instructions clause "Operation in explosive atmospheres", document Rev..7 and see the bottom of the radio "Warning potential electrostatic hazard -see instructions", described in document Rev..2)
4 ' Certificate No. : IECEx BVS.0099X Issue No.: 3 Page 4 of 5 EQUIPMENT( continued): Technical Parameters. Unchanged I Copy of Marking Plate See Annex
5 Certificate No.: IECEx BVS.0099X Issue No.: 3 Page 5 of 5 :DETAILS OF CERTIFICATE CHANGES (for issues and above): I I Reasons for this supplement are some electrical and mechanical modifications of the radiotelephone type FT4 * Ex_ a C ***series for 380 MHz MHz and type FT 4 * Ex_ c C *** series for 40 MHz MHz. They have no effect for the explosion protection. New for this supplement is the following antenna: Antenna type be FT4, frequency range MHz (Part-No ) New for this supplement is the following leather case: Leather case with accessories and eyelets (Part.-No )! New for this supplement are the following micro SO Ca rds: 4 GB (Part-No ) 8 GB (Part-No ) Annex: BVS 0099X_Funkwerk_Annex_issue_3_.pdf
6 J> DEKRA Certificate No.: IECEx BVS.0099 X issue 3 Annex Page of 2 Copy of Marking Plate The marking shall be visible, legible and durable. It shall contain the following:. Radio type FT4 * Ex_ * C *** *6. Radiotelephone type FT 4 * Ex_ a C*** or. *I I_ The name and address of the manufacturer ~ = =- Type FT4 * Ex_ a C *** =c::le< Ex ib I Mb QJ ~-- Ex ib IIC T4 Gb ~~ ~ ;:: -~ g! Ex ib IIIC T25 C Db.. J C ~ T a ~ +55 C... ~~- A ~ Serial number ~ Z' * ~ ~ 4) Certificate number 0 '"' "' - """'--=.2 Radiotelephone type FT 4 * Ex_ c C*** ID ~ The name and address of the manufacturer * Type FT4 * Ex_ c C *** Ex ib I Mb Ex ib IIC T4 Gb Ex ib IIIC T 25 C Db -20 C ~ Ta ~+55 C Serial number Certificate number 2. Packing label for antennas 2. Packing label for antenna type c FT4 Antenna type c FT 4 Antenna length 69 mm Frequency range MHz, SMA Part number Packing label for antenna type a FT4 Antenna type a FT4 Antenna length 79 mm Frequency range MHz, SMA Part number Packing label for antenna type b FT4 Antenna type b FT 4 Antenna length 7 4 mm Frequency range MHz, SMA Part number Packing label for antenna type ab FT4 Antenna type ab FT 4 Antenna length 70 mm Frequency range MHz, SMA Part number [!:' ~ i 0 ~;; J': ~ ;g ~ ~ Q) ~ ~~ ~--= t9 ~ ~~ ~ l==l'7
7 J> DEKRA Certificate No.: IECEx BVS.0099 X issue 3 Annex Page 2 of Packing label for antenna type be FT4 Antenna type be FT 4 Antenna length 44 mm Frequency range MHz, SMA Part number Leather case with access accessories and clip Part number micro SO Card 4. micro SO Card 2 GB Part number micro SO Card 4GB Part number micro SO Card 8GB Part number Open leather case Part number Leather case without access accessories Part number Leather case with access accessories Part number Shoulder strap Part number Belt holder 32 mm FT 4 Ex Part number Belt holder 50 mm FT 4 Ex Part number Screw on dock FT 4 Ex Part number Leather loop 50 mm FT4 Ex Part number Leather case with access accessories and eyelets Part number Click fast stud FT4 Ex Part number Clip FT4 Ex antistatic Part number
IECEx Certificate of Conformity
IECE Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Eplosive Atmospheres for rules and details of the IECE Scheme visit www.iece.com Certificate No.: Status:
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www. iecex.com Status: Current issue No.:1 Certificate history:
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Issue No.
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationOperating Manual. isolate501
Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationCertificate of Conformity
Certificate of Conformity Certificate No: AUS Ex 01.3733X Issue 0: Original Issue: 7/8/2001 Issue 2: 10/8/2004 Date of Expiry: 7/8/2011 Certificate Holder: Pempek Systems Pty Ltd Unit 3/13 Hoyle Avenue
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed
More informationCertification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT
Certificate of Conformity Certificate No: ANZEx 11.2009 Issue: 0 16 December 2011 Original Issue Applicant: Pepperl+Fuchs GmbH Lilienthalstrasse 200 68307 Mannheim GERMANY Electrical Equipment: Isolation
More informationSolexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:
OVERVIEW The Solexy RX series explosion proof and intrinsically safe antenna coupler is an integrated protection device that facilitates non-ex certified radio antenna installation in hazardous areas.
More informationSOLUTIONS BRIEF MOTOTRBO AND SOLAS
SOLUTIONS BRIEF MOTOTRBO AND SOLAS To meet that need, a conference held by the United Nations in 1948 adopted a convention establishing the International Maritime Organization (IMO) to improve maritime
More informationTranslation (1 ) 3. Supplement to the EC-Type Examination Certificate (2) Equipment and protective systems intended for use in potentially explosive atmospheres - Directive 94/9/EC Supplement accordant
More informationCertificate of Conformity
Applicant: Moore Industries International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A Electrical Apparatus: Fully Encapsulated PC-Programmable Temperature Transmitters (TRX: nonisolated;
More information1> DEKRA Translation 4 th Supplement (Supplement in accordance with Directive 94/9/EC Annex III number 6) to the EC-Type Examination Certificate DMT 01 ATEX E 149 X Equipment: Manufacturer: Address: Mass
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationMicro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc
IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationIntrinsically Safe Radios For Firefighters - SOLAS Regulation II-2/10
Product And Company Identification: Date Prepared: Jun 20, 2014 Manufacturer s Name: Entel Subject: Intrinsically Safe Two-way Portables To Comply With IMO Regulation The Maritime Safety Committee (MSC),
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationInstallation & Operating Manual. iwap202
Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and
More informationMT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationIntrinsically Safe Radios For Firefighters SOLAS 2012 MSC.338(91) Regulation II-2/ V1.1 Flyer
Product And Company Identification: Date Prepared: Jun 20, 2014 Manufacturer s Name: Entel UK Limited, Address: 320 Centennial Avenue, Centennial Park, Elstree, Borehamwood, Herts,WD6 3TJ Telephone Number:
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationAdjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**
Assembly Instructions for: PL ** Series Junction Boxes AI 23 / Issue W - 01/ IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Box CAT II 2G for use in Zone
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters
Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14
More informationMicro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc
ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc 5700 ATEX Installation
More informationSafety Manual. Omni-ID UHF Tags
Safety Manual Omni-ID UHF Tags This page is intentionally left blank. Document Number 330556 (See Last Page for Revision Details) 2012 Extronics Limited. This document is Copyright Extronics limited. Extronics
More informationDirectional valves Coils Series CO1. Brochure
Directional valves Coils Series CO1 Brochure 2 Directional valves Coils Series CO1 Form C, coil kit Coil width 15 mm 3 M8, coil kit Coil width 15 mm 5 form B Coil width 22 mm 7 Form B, industry Coil width
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2411253 Issued to: Balluff Incorporated 8125 Holton Dr Florence, Kentucky 41042 USA Attention: Jim Ramler The products listed below are eligible to bear the CSA Mark
More informationSicherheit, auf die Sie sich verlassen können
CEAG Products Ex-emergency lighting CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Explosion protected safety luminaire for Zone 1/2 und 21/22 Explosion protected safety luminaire Zone
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationDTEx Series. Tough. Intrinsically Safe Land Portables. Business Critical Communications
Business Critical Communications Commercial grade construction ATEX II 2G Ex ib IIA T4 Gb ATEX II 2G Ex ib IIC T4 Gb Ex ib IIA T4 Gb DMR digital & Analogue mode Submersible IP68 Tough CRYSTAL CLEAR AUDIO
More informationUser's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R
User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 Table of contents Table of contents
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 285573 Date of issue...: 2015-09-15
More informationTC7000 Thermal Imaging Camera
User Manual TC7000 Thermal Imaging Camera Supplied by.com Call us on +44 (0)8 96 940 Email info@47able.com USER MANUAL TC7000 INTRINSICALLY SAFE THERMAL IMAGING CAMERA www.cord-ex.com Congratulations You
More informationDescription. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461
October 13, 2017 Annexe to: IECEx CML 15.0063X Issue 1 Applicant: Apparatus: Braun GmbH Isolating Amplifier D461 Description The Isolating Amplifier D461 is an intrinsic safety associated apparatus
More informationDisclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
More informationCertificate of Conformity
pplicant: Moore Industries-International Inc. 16650 Schoenborn Street North Hills C 91343 United States of merica Electrical pparatus: Current to Pressure Transmitter Models IPX2, IPX2-NG, IPH2 and IPT2
More informationiant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas
iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas This page is intentionally left blank. Document Number 403449
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More informationAdjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**
Assembly Instructions for: PL ** Series Junction Boxes IMPORTANT: This document should be read carefully before commencing installation Zones of Use for Box - as defined in IEC/EN 00-0 and IEC/EN 00--1
More informationUSER MANUAL TC7000/TC7150 INTRINSICALLY SAFE THERMAL IMAGING CAMERA
USER MANUAL TC7000/TC70 INTRINSICALLY SAFE THERMAL IMAGING CAMERA www.cord-ex.com Congratulations You are the owner of the first fully radiometric thermal imaging camera designed and certified specifically
More informationPT790 Ex Intrinsically safe TETRA handheld radio.
PT790 Ex Intrinsically safe TETRA handheld radio The PT790 Ex is the first TETRA handheld radio worldwide with the highest level of intrinsic safety "ia". Its robust design and its safety functions substantially
More informationCertificate of Conformity
Applicant: Trolex Limited Newby Road, Hazel Grove Stockport SK7 5DY UK Electrical Apparatus: Programmable Sensor Controller Type TX9042 Type of Protection: Ex ia Marking Code: Trolex Ltd TX9042 Programmable
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2002912 Master Contract: 242288 Project: 2075823 Date Issued: 2008/10/08 Issued to: Ascom Sweden AB 2 Grimbodalen Göteborg, 402 76 Sweden Attention: Ms. Tania Ottebrink
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationBEST CONNECTIONS IN EVERY ENVIRONMENT
BEST CONNECTIONS IN EVERY ENVIRONMENT VG & MIL SPACE & AEROSPACE ATEX & IECEX SUBSEA FIBER OPTIC ACCESSORIES CABLE HARNESSES CUSTOMIZED PRODUCTS SERVICE DIN EN 9120 DIN ISO 9001 VG96927 ATEX IECEX VG &
More informationIS Series Portfolio. Intrinsically Safe DMR Radios.
IS Series Portfolio Intrinsically Safe DMR Radios UL / ATEX / IECEx / FM / CSA / UL / CQST IIC Certified Designed for Hazardous Working Environments GPS, Man Down and Integration with Data Applications
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationIntrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i
Intrinsically Safe Compact Controller CTR 210i Intrinsically Safe Bargraph Indicator BGI 210i DMT 02 ATEX E 148 2. Supplement also grahics display Revision 4 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.:
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2)
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-P-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust BExBG05D-P-SIL 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.
More informationELECTROMAGNETIC RECEIVER TOPSIDE ATEX OPERATING MANUAL
ELECTROMAGNETIC RECEIVER TOPSIDE ATEX OPERATING MANUAL The 3002X 3003X system is a 22Hz Electromagnetic Receiver ATEX compliant system for use in Zone 1 areas for pig locating and tracking onshore and
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter
Operating Instruction OI/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Measurement made easy Change from one to two columns Short product description Coriolis
More informationiant101 Zone 1 Omni Directional Antenna
iant101 Zone 1 Omni Directional Antenna External Antenna offering increased flexibility for positioning and greatly enhanced RF Propagation. ATEX Ex t IIIC T85 C Db IECEx Ex t IIIC T85 C Db -40 C to 60
More informationON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02
ON!Track smart tag AI T380 English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free
More informationTransducer transmitter BILT 4 II 2(1) G. Technical Manual
GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationAmendment to Test Report
Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 270292 Main Report No.... : 261294
More informationIECEx Ex TEST REPORT COVER
IECEx Ex TEST REPORT COVER ExTR Reference Number... : ExTR Free Reference Number... : 09/0519 GB/BAS/ExTR10.0134/00 Complied by + signature (ExTL)... : R. Powney... Reviewed by + signature (ExTL)... :
More information[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011
Quick Installation Guide Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications End www.rosemount.com
More informationUser manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD
User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3
More informationTEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements
Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Number... : 246847 Date of issue... : October
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More information100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features
C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,
More informationPV 102. IECEx. Piezoelectric velocity sensor FEATURES. From the Vibro-Meter product line
FEATURES From the Vibro-Meter product line Designed for medium temperature industrial applications: 50 to +120 C ( 58 to +248 F) Frequency response: 6.0 to 2500 Hz: ±10 % to 5000 Hz: ±3 db Ultra low-noise
More informationAccutech AI10 & AV10. Wireless multi-input field unit
ccutech I10 & V10 Wireless multi-input field unit 1 Ideal for adding wireless capabilities to existing or new wired measurement sensors such as radar tank gauges, flow meters and chemical analyzers, the
More informationUser manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD
User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3
More informationAssemblies according to the Pressure Equipment Directive - a consideration provided by the PED-AdCo Group 1 -
Assemblies according to the Pressure Equipment Directive - a consideration provided by the PED-AdCo Group 1-1 Preliminary remark... 1 2 Fundamentals... 2 2.1 Terms / criteria... 2 2.2 Scope / limitations...
More informationWireless Power Transfer Devices (Wireless Chargers)
Issue 1 August 2014 Spectrum Management and Telecommunications Radio Standards Specification Wireless Power Transfer Devices (Wireless Chargers) Aussi disponible en français CNR-216 Preface Radio Standards
More informationOPTIWAVE 7300 C Supplementary instructions
OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General
More informationIECEx Certificate of Conformity Annexe
for Certificate No.: IECEx TSA 13.0023X Issue No.: 0 Description: The Measuring Gauge of type series SMALL * / / / / / / / / / / * / * is an intrinsically safe supplied apparatus providing different electronic
More informationLink Mobile Gateway User Guide A ProVIEW System Component
A ProVIEW System Component Omni-ID office locations: US UK China India Southeast Asia Germany 1. CONTENTS 1. Introduction... 3 About this Document... 3 Related Products... 3 Regulatory Approvals... 4 Certifications...
More informationSafety Instructions Nivotester FTC625, FTC325
XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for
More informationIntroduction. Additional Information. Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made easy
ABB MEASUREMENT & ANALYTICS COMMISSIONING INSTRUCTION TTF200 Field-mount temperature transmitter Temperature transmitter for HART protocol. Suitable for all standard requirements Measurement made easy
More informationEx instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,
Ex instruction manual Rotamass Coriolis mass flow meter IM 01U10X02-00EN-R_002, 2nd edition, 2016-09-22 Table of contents Table of contents 1 Introduction... 4 1.1 Scope of application... 4 1.2 Applicable
More informationDisclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
More informationGETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous
GETTING STARTED GUIDE NI 9228 8 AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous This document explains how to connect to the NI 9228. Note Before you begin, complete the software and hardware installation procedures
More informationInterface Manual Tank Level Float Stick System
1 Interface Manual Tank Level Float Stick System SignalFire Model: Sentinel-FS-3BIS The SignalFire Sentinel Float Stick Node is an Intrinsically Safe device with the following features: - Standard SignalFire
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More information