TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 5

Size: px
Start display at page:

Download "TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 5"

Transcription

1

2 Revision History Version Issue Date Revisions Content Rev. 01 Jan. 24, 2018 Initial Issue Rev. 02 Mar. 29, 2018 Update the report template, update the test item of Radiated Emission and The restricted band bandedge.and revise some written and descript error on page 6/7/8.update the AR report. TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory Identification of the Responsible Testing Location Laboratory Condition Announce PRODUCT INFORMATION Applicant Information Manufacturer Information Factory Information General Description for Equipment under Test (EUT) Ancillary Equipment Technical Information Additional Instructions SUMMARY OF TEST RESULTS Test Standards Verdict GENERAL TEST CONFIGURATIONS Test Environments Test Equipment List Measurement Uncertainty Description of Test Setup For Antenna Port Test / 31

3 4.4.2 For AC Power Supply Port Test For Radiated Test (Below 30 MHz) For Radiated Test (30 MHz-1 GHz) For Radiated Test (Above 1 GHz) TEST ITEMS Antenna Requirements Relevant Standards Antenna Anti-Replacement Construction Antenna Gain db and 99% Bandwidth Limit Test Setups Test Procedure Test Result AC Conducted Emission Limit Test Setups Test Procedure Test Result Radiated Spurious Emission and bandedge measurement Limit Test Setups Test Procedure Test Result ANNEX A TEST RESULT A.1 20dB bandwidth and 99% bandwidth A.2 AC Conducted Emission A.3 Radiated Emission and Bandedge Measurement ANNEX B TEST SETUP PHOTOS ANNEX C EUT EXTERNAL PHOTOS / 31

4 ANNEX D EUT INTERNAL PHOTOS / 31

5 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) 1.1 Identification of the Testing Laboratory Company Name Address Phone Number Shenzhen BALUN Technology Co., Ltd. Block B, 1st FL, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1.2 Identification of the Responsible Testing Location Test Location Shenzhen BALUN Technology Co., Ltd. Address Accreditation Certificate Description 1.3 Laboratory Condition Ambient Temperature 20 to 25 Ambient Relative Humidity Ambient Pressure 1.4 Announce Block B, 1st FL, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China The laboratory has been listed by Industry Canada to perform electromagnetic emission measurements. The recognition numbers of test site are 11524A-1. The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196. The laboratory is a testing organization accredited by American Association for Laboratory Accreditation(A2LA) according to ISO/IEC The accreditation certificate is The laboratory is a testing organization accredited by China National Accreditation Service for Conformity Assessment (CNAS) according to ISO/IEC The accreditation certificate number is L6791. All measurement facilities used to collect the measurement data are located at Block B, FL 1, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China % - 55% 100 kpa kpa (1) The test report reference to the report template version v6.6. (2) The test report is invalid if not marked with the signatures of the persons responsible for preparing and approving the test report. (3) The test report is invalid if there is any evidence and/or falsification. (4) The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. (5) This document may not be altered or revised in any way unless done so by BALUN and all revisions are duly noted in the revisions section. (6) Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory. 5 / 31

6 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Address AEOTEC LIMITED FLAT/RM 704, 7/F, BRIGHT WAY TOWER, 33 MONG KOK ROAD, MONG KOK, KL, HK 2.2 Manufacturer Information Manufacturer Address AEOTEC LIMITED FLAT/RM 704, 7/F, BRIGHT WAY TOWER, 33 MONG KOK ROAD, MONG KOK, KL, HK 2.3 Factory Information Factory Address N/A N/A 2.4 General Description for Equipment under Test (EUT) EUT Name Model Name Under Test Series Model Name Description of Model name differentiation Hardware Version Software Version Dimensions (Approx.) Weight (Approx.) Network and Wireless connectivity LED Bulb 6: Multi-White ZWA001-A N/A N/A N/A N/A N/A N/A Z-WAVE 902MHz-928MHz 2.5 Ancillary Equipment Note: Not applicable. 6 / 31

7 2.6 Technical Information The requirement for the following technical information of the EUT was tested in this report: Modulation Type Product Type Frequency Range Tested Channel Antenna Type Antenna Gain Z-WAVE Mobile Portable Fix Location 902 MHz to 928 MHz Low (908.4 MHz), Middle ( MHz), High (916 MHz) Dipole Antenna -2.3 dbi (In test items related to antenna gain, the final results reflect this figure.) 2.7 Additional Instructions EUT Software Settings: Special software is used. Mode The software provided by client to enable the EUT under transmission condition continuously at specific channel frequencies individually. During testing, Channel and Power Controlling Software provided by the customer was used to control the operating channel as well as the output power level. The RF output power selection is for the setting of RF output power expected by the customer and is going to be fixed on the firmware of the final end product. Power level setup in software Test Software Version SSCOM4.2 Support Units Description Manufacturer Model (Software installation media) Laptop Lenovo E31-80 Mode Channel Frequency Soft Set GFSK High 916 Power parameter Settings is Middle FSK 63 Low / 31

8 Run Software: 8 / 31

9 3 SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 47 CFR Part 15, Subpart C Intentional Radiators ( Edition) 2 ANSI C American National Standard for Testing Unlicensed Wireless Devices 3.2 Verdict No. Description FCC Part No. ISED Part No. Test Result Verdict Remark 1 Antenna Requirement RSS-Gen Pass Note db and 99% Bandwidth (c) RSS-Gen 6.6 ANNEX A.1 N/A -- 3 AC Conducted Emission RSS-Gen 8.8 ANNEX A.2 N/A (a) RSS-210 B.10 Radiated Emission Test (d) RSS-Gen 8.9 Band Edge Measurement RSS-Gen 8.10 ANNEX A.3 Pass Note 2 Note 1 : The EUT has a permanently and irreplaceable attached antenna, which complies with the requirement FCC Note 2: the limit is 50dB less than the peak value of fundamental frequency or meet radiated emission limit in section / 31

10 4 GENERAL TEST CONFIGURATIONS 4.1 Test Environments During the measurement, the normal environmental conditions were within the listed ranges: Relative Humidity 45% - 55% Atmospheric Pressure 100 kpa kpa Temperature NT (Normal Temperature) +22 to +25 Working Voltage of the EUT NV (Normal Voltage) 120 V 4.2 Test Equipment List Description Manufacturer Model Serial No. Cal. Date Cal. Due Spectrum Analyzer ROHDE&SCHWARZ FSV Vector Signal Generator ROHDE&SCHWARZ SMBV100A Signal Generator ROHDE&SCHWARZ SMB100A Switch Unit with OSP- B157 ROHDE&SCHWARZ OSP Spectrum Analyzer AGILENT E4440A MY EMI Receiver ROHDE&SCHWARZ ESRP LISN SCHWARZBECK NSLK Bluetooth Tester ROHDE&SCHWARZ CBT Power Splitter KMW DCPD-LDC Power Sensor ROHDE&SCHWARZ NRP-Z Attenuator (20 db) KMW ZA-S Attenuator (6 db) KMW ZA-S DC Power Supply ROHDE&SCHWARZ HMP Temperature Chamber ANGELANTIONI SCIENCE NTH64-40A Test Antenna- Loop(9 khz-30 MHz) SCHWARZBECK FMZB Test Antenna- Bi-Log(30 MHz-3 GHz) SCHWARZBECK VULB Test Antenna- BBHA SCHWARZBECK Horn(1-18 GHz) 9120D 9120D Test Antenna- Horn( GHz) SCHWARZBECK BBHA Anechoic Chamber RAINFORD 9m*6m*6m N/A Anechoic Chamber EMC 21.1m*11.6 TECHNOLOGY LTD m*7.35m N/A Shielded Enclosure ChangNing CN Signal Generator ROHDE&SCHWARZ SMB100A Power Amplifier OPHIR RF 5225F / 31

11 Description Manufacturer Model Serial No. Cal. Date Cal. Due Power Amplifier OPHIR RF 5273F Directional Coupler Werlantone C N/A N/A Directional Coupler Werlantone CHP-273E S00801z-01 N/A N/A Feld Strength Meter Narda EP WX Mouth Simulator B&K Sound Calibrator B&K Sound Level Meter B&K NL Ear Simulator B&K Ear Simulator B&K Audio analyzer B&K UPL Measurement Uncertainty The following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Measurement Value Occupied Channel Bandwidth ±4% RF output power, conducted Power Spectral Density, conducted Unwanted Emissions, conducted All emissions, radiated Temperature ±1.4 db ±2.5 db ±2.8 db ±5.4 db ±1 C Humidity ±4% 4.4 Description of Test Setup For Antenna Port Test (Diagram 1) 11 / 31

12 4.4.2 For AC Power Supply Port Test (Diagram 2) For Radiated Test (Below 30 MHz) (Diagram 3) 12 / 31

13 4.4.4 For Radiated Test (30 MHz-1 GHz) (Diagram 4) For Radiated Test (Above 1 GHz) (Diagram 5) 13 / 31

14 5 TEST ITEMS 5.1 Antenna Requirements Relevant Standards FCC & (b) An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of , , , , or Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded. If directional gain of transmitting antennas is greater than 6 dbi, the power shall be reduced by the same level in db comparing to gain minus 6 dbi. For the fixed point-to-point operation, the power shall be reduced by one db for every 3 db that the directional gain of the antenna exceeds 6 dbi. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the FCC rule Antenna Anti-Replacement Construction The Antenna Anti-Replacement as following method: Protected Method Description The antenna is embedded in the An embedded-in antenna design is used. product. Reference Documents Photo Item Antenna Gain The antenna peak gain of EUT is less than 6 dbi. Therefore, it is not necessary to reduce maximum peak output power limit. 14 / 31

15 db and 99% Bandwidth Limit FCC (c); Intentional radiators operating under the alternative provisions to the general emission limits, as contained in through and in Subpart E of this part, must be designed to ensure that the 20 db bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated Test Setups See section for test setup description for the antenna port. The photo of test setup please refer to ANNEX B Test Procedure Use the following spectrum analyzer settings: Span = approximately 2 to 3 times the 20 db bandwidth, centered on a hopping channel RBW 1% of the 20 db bandwidth VBW RBW Sweep = auto Detector function = peak Trace = max hold Test Result Please refer to ANNEX A / 31

16 5.3 AC Conducted Emission Limit FCC For an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150 khz to 30 MHz shall not exceed the limits in the following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN). Frequency range Conducted Limit (dbµv) Quai-peak Average to to Test Setups See section for test setup description for the antenna port. The photo of test setup please refer to ANNEX B Test Procedure The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz) for which the device is capable of operation. A device rated for 50/60 Hz operation need not be tested at both frequencies provided the radiated and line conducted emissions are the same at both frequencies Test Result Please refer to ANNEX A / 31

17 5.4 Radiated Spurious Emission and bandedge measurement Limit FCC (a) Except as provided in paragraph (a) of this section, the field strength of emissions from intentional radiators operated within these frequency bands shall comply with the following: Frequency Field Strength of Fundamental Field Strength of Harmonics (mv/m) (µv/m) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 db below the level of the fundamental or to the general radiated emission limits in , whichever is the lesser attenuation. According to FCC section (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency Field Strength (µv/m) Measurement Distance (m) /F(kHz) /F(kHz) Above Note: 1. For Above 1000 MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20 db above the maximum permitted average limit. 2. For above 1000 MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK) Test Setups See section for test setup description for the antenna port. The photo of test setup please refer to ANNEX B Test Procedure The measurement frequency range is from 9 khz to the 10th harmonic of the fundamental frequency. The Turn Table is actuated to turn from 0 to 360, and both horizontal and vertical polarizations of the Test Antenna are used to find the maximum radiated power. Mid channels on all channel bandwidth verified. Only the worst RB size/offset presented. The power of the EUT transmitting frequency should be ignored. 17 / 31

18 All Spurious Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Use the following spectrum analyzer settings: Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1 GHz, 100 khz for f < 1 GHz VBW RBW Sweep = auto Detector function = peak Trace = max hold Test Result Please refer to ANNEX A / 31

19 ANNEX A TEST RESULT A.1 20dB bandwidth and 99% bandwidth Test Data Channel Frequency 20 db Bandwidth 99% Bandwidth Low Middle High Test plots 20 db Bandwidth LOW CHANNEL MIDDLE CHANNEL HIGH CHANNEL 19 / 31

20 99% Bandwidth LOW CHANNEL MIDDLE CHANNEL HIGH CHANNEL 20 / 31

21 A.2 AC Conducted Emission Note 1 : The EUT is working in the Normal link mode. Test Data and Plots PHASE L No. Frequency Results Factor (db) Limit Margin Detector Line Verdict (dbuv) (dbuv) (db) Peak L Line Pass 1** AV L Line Pass Peak L Line Pass 2** AV L Line Pass Peak L Line Pass 3** AV L Line Pass Peak L Line Pass 4** AV L Line Pass Peak L Line Pass 5** AV L Line Pass Peak L Line Pass 6** AV L Line Pass 21 / 31

22 PHASE N No. Frequency Results Factor (db) Limit Margin Detector Line Verdict (dbuv) (dbuv) (db) Peak N Line Pass 1** AV N Line Pass Peak N Line Pass 2** AV N Line Pass Peak N Line Pass 3** AV N Line Pass Peak N Line Pass 4** AV N Line Pass Peak N Line Pass 5** AV N Line Pass Peak N Line Pass 6** AV N Line Pass 22 / 31

23 A.3 Radiated Emission and Bandedge Measurement The low frequency, which started from 9 khz to 30 MHz, was pre-scanned and the result which was 20 db lower than the limit line per 15.31(o) was not reported. Test Data and Plots (30 MHz ~ 1 GHz) Note: The bold frequency is the fundamental. Note: The bolded part indicates that the test value with allowed-bandedge. Low Channel 30 MHz to 1 GHz, ANT V No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass 23 / 31

24 Low Channel 30 MHz to 1 GHz, ANT H No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass 24 / 31

25 Middle Channel 30 MHz to 1 GHz, ANT V No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass 25 / 31

26 Middle Channel 30 MHz to 1 GHz, ANT H No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass 26 / 31

27 High Channel 30 MHz to 1 GHz, ANT V No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass 27 / 31

28 High Channel 30 MHz to 1 GHz, ANT H No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass 28 / 31

29 Test Data and Plots (1 GHz ~ 10th Harmonic) Note 1 : The marked is the harmonic signal. Note 2 : Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency. Note 3 : Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 db below the level of the fundamental or to the general radiated emission limits in , whichever is the lesser attenuation. Note 4 : Measurements above show only up to 6 maximum emissions noted, or would be lesser if no specific emissions from the EUT are recorded (ie: margin>20 db from the applicable limit) and considered that's already beyond the background noise floor. Note 5 : Radiated emissions measured in frequency above 1000 MHz were made with an instrument using Peak detector mode and average detector mode of the emission shown in Actual FS column. LOW CHANNEL 1 GHz to 10 GHz, ANT V No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Vertical Pass Peak Vertical Pass Note Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass LOW CHANNEL 1 GHz to 10 GHz, ANT H No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Horizontal Pass Peak Horizontal Pass Note Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass MIDDLE CHANNEL 1 GHz to 10 GHz, ANT V No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Vertical Pass Peak Vertical Pass Note Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass 29 / 31

30 MIDDLE CHANNEL 1 GHz to 10 GHz, ANT H No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Horizontal Pass Peak Horizontal Pass Note Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass HIGH CHANNEL 1 GHz to 10 GHz, ANT V No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass Peak Vertical Pass HIGH CHANNEL 1 GHz to 10 GHz, ANT H No. Frequency Results Factor (db) Limit Margin Detector Table Height ANT Verdict (db) (o) (cm) Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Peak Horizontal Pass Note: The restricted-band bandedge is far from the main frequency, and all of them are bottom noise, so they are not reported. 30 / 31

31 ANNEX B TEST SETUP PHOTOS Please refer the document BL-SZ17C0143-AR.PDF. ANNEX C EUT EXTERNAL PHOTOS Please refer the document BL- SZ17C0143-AW.PDF. ANNEX D EUT INTERNAL PHOTOS Please refer the document BL- SZ17C0143-AI.PDF. --END OF REPORT-- 31 / 31

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 4

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 4 Revision History Version Issue Date Revisions Content Rev. 01 Mar. 3, 2016 Initial Issue TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION)... 4 1.1 Identification of the Testing Laboratory...

More information

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 5

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 5 Revision History Version Issue Date Revisions Content Rev. 01 Jun. 26, 2017 Initial Issue TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION)... 5 1.1 Identification of the Testing Laboratory...

More information

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 5

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 5 Revision History Version Issue Date Revisions Content Rev. 01 May 25, 2018 Initial Issue Rev. 02 May 29, 2018 Added the test software in Equipment lists in section 4.2; Corrected the description of EIRP

More information

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 6

TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION) Identification of the Testing Laboratory... 6 Revision History Version Issue Date Revisions Content Rev. 01 Feb. 2, 2016 Initial Issue TABLE OF CONTENTS 1 ADMINISTRATIVE DATA (GENERAL INFORMATION)... 6 1.1 Identification of the Testing Laboratory...

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4 Revision History Version Issue Date Revisions Content Rev. 01 Jul. 25, 2018 Initial Issue Rev. 02 Sep. 05, 2018 Added the USB test mode in section 4.4 Test Configurations and data in ANNEX A TEST RESULTS.

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4 Revision History Version Issue Date Revisions Content Rev. 01 May 19, 2017 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION... 4 1.1 Identification of the Testing Laboratory... 4 1.2 Identification

More information

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4 TABLE OF CONTENTS 1. GENERAL INFORMATION... 4 1.1. EUT DESCRIPTION... 4 1.2. TEST STANDARDS AND RESULTS... 5 1.3. FACILITIES AND ACCREDITATIONS... 6 1.3.1. FACILITIES... 6 1.3.2. TEST ENVIRONMENT CONDITIONS...

More information

TEST REPORT : 2AIB7MGS. TEST DATE : to

TEST REPORT : 2AIB7MGS. TEST DATE : to TEST REPORT APPLICANT : Hohem Technology Co.,Ltd PRODUCT NAME : 3-Axis Stabilizing Gimbal for Smartphone MODEL NAME BRAND NAME FCC ID STANDARD(S) : isteady Mobile : Hohem : 2AIB7MGS : 47 CFR Part 15 Subpart

More information

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FCC TEST REPORT APPLICANT : GN Netcom Inc PRODUCT NAME : Bluetooth Headsets MODEL NAME : HSC040W TRADE NAME : N/A BRAND NAME : Jabra FCC ID : BCE-HSC040W STANDARD(S) : 47 CFR Part 15 Subpart B TEST DATE

More information

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax: EMC TEST REPORT Report No.: Product: Model No. : FCC2012-8029E GSM Tracker PRIME AT PLT Brand Name: PRIME Applicant: Address: Issued by: Lab Location: RADISYS CORPORATION 601 North Congress Ave Suite 439,

More information

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST... Table of Contents 1. GENERAL INFORMATION... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST... 4 1.2 RELATED SUBMITTAL(S) / GRANT (S)... 7 1.3 TEST METHODOLOGY... 7 1.4 EQUIPMENT MODIFICATIONS... 7

More information

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION...3 2. GENERAL INFORMATION...4 2.1 Equipment under Test (EUT) Description...4 2.2 Test Standards and Results...5 2.3 Facilities and Accreditations...6 2.3.1

More information

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD IC #: 4324A-BRCM1029 REPORT NUMBER: 07U11199-1C ISSUE DATE:

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4 Revision History Version Issue Date Revisions Content Rev. 01 Nov. 08, 2017 Initial Issue Rev. 02 Dec. 05, 2017 Identified the actual channel number for testing in annex A. Added the filter information

More information

TABLE OF CONTENTS. Report No.: BL-SZ

TABLE OF CONTENTS. Report No.: BL-SZ Revision History Version Issue Date Revisions Content Rev. 01 Jul. 20, 2017 Initial Issue Rev. 02 Aug. 02, 2017 Update the test method in section 5.2.3 and other changes Rev. 03 Rev. 04 Aug. 07, 2017 Aug.

More information

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29 FCC REPORT Applicant: Dongguan Hele Electronics Co., Ltd. Address of Applicant: Dalingya Industrial Zone, Daojiao Town, Dongguan City, Guangdong China Equipment Under Test (EUT) Product Name: Model No.:

More information

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS201708000040F02 FCC REPORT Applicant: Address of Applicant: Manufacturer: Dongguan Hele Electronics Co.,Ltd. Dalingya Industrial Zone,Daojiao Town,Dongguan City,Guangdong,China Dongguan

More information

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer: FCC REPORT Applicant: Address of Applicant: Manufacturer: Striiv Inc. 570 E1 Camino Real #200, Redwood City, CA 94063, United States Striiv Inc. Address of 570 E1 Camino Real #200, Redwood City, CA 94063,

More information

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15. Page 1 of 51 Report No.: T1851663 01 TEST REPORT FCC ID: 2AGJ5WAP-30 Applicant Address : Gonsin Conference Equipment Co., Ltd : No.401-406,Block C, Idea Industry Park, No.41 Fengxiang Road, Shunde, Foshan,

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3 Revision History Version Issue Date Revisions Rev. 01 July 04, 2014 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION... 3 1.1 Identification of the Testing Laboratory... 3 1.2 Identification of the

More information

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above. + Applicant: Address of Applicant: Manufacturer: FCC REPORT Dongguan Hele Electronics Co.,Ltd. Report No.: GTS201708000040F01 Dalingya Industrial Zone,Daojiao Town,Dongguan City,Guangdong,China Dongguan

More information

Pass* * In the configuration tested, the EUT complied with the standards specified above.

Pass* * In the configuration tested, the EUT complied with the standards specified above. No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 Email: ee.shenzhen@sgs.com Page: 1 of 41 Application

More information

RF TEST REPORT. Tel: Fax:

RF TEST REPORT. Tel: Fax: RF TEST REPORT Report No.: SET2015-03808 Product Name: Industrial Handheld Terminal FCC ID: 2AC68-AUTOID9 Model No. : AUTOID9 AUTOID9HC Applicant: Jiangsu SEUIC Technology Co.,Ltd. Address: No 23, Wenzhu

More information

TEST REPORT FCC ID: 2ADMF-HC06. : bluetooth module keyes HC-06, keyes hc-05, FUNDUINO HC-06, FUNDUINO hc-05

TEST REPORT FCC ID: 2ADMF-HC06. : bluetooth module keyes HC-06, keyes hc-05, FUNDUINO HC-06, FUNDUINO hc-05 Shenzhen Certification Technology Service Co., Ltd. 2F, Building B, East Area of Nanchang Second Industrial Zone, Gushu 2 nd Road, Bao'an District, Shenzhen 518126, P.R. China TEST REPORT FCC ID: 2ADMF-HC06

More information

FCC ID: 2ALT5-GW6088

FCC ID: 2ALT5-GW6088 TEST REPORT FCC ID: 2ALT5-GW6088 For GREAT WORLD LTD Electric Heater Model No. : GW-6078TBT, GW-6088TBT, GW-5088C-AMBT, GW-6088TMBT Trade Name : N/A Prepared for : Address : GREAT WORLD LTD 406 Room 1,

More information

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial Page (2 ) of (34) Revision history Revision Date of issue Test report No. Description - 2014.08.25 Initial Page (3 ) of (34) TABLE OF CONTENTS 1. General information... 4 1.1. EUT description... 4 1.2.

More information

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission 7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission 7.1 Test Setup Refer to the APPENDIX I. 7.2 Limit According to 15.247(d), in any 100 khz bandwidth outside the frequency band

More information

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR WLAN 2X2 MIMO 802.11a/b/g/n/ac with BLUETOOTH MODEL NUMBER: P2180 REPORT NUMBER: 15U21878-E2V1

More information

FCC ID: B4OCC264BPA-S

FCC ID: B4OCC264BPA-S FCC TEST REPORT FCC ID: B4OCC264BPA-S Product : Bluetooth LE Module Model Name : CC264BPA-S, CC265BPA-S, CC26xBPA Brand : GT-tronics Report No. : PTC801181160622E-FC01 Prepared for GT-tronics HK Ltd Unit

More information

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR 2.4GHz LE MODULE MODEL NUMBER: RN4020 REPORT NUMBER: 14U17191-1 ISSUE DATE: MARCH 21, 2014

More information

DIRECTORY SZ W03 1. GENERAL INFORMATION... 3

DIRECTORY SZ W03 1. GENERAL INFORMATION... 3 DIRECTORY 1. GENERAL INFORMATION... 3 1.1. EUT Description... 3 1.2. Test Standards and Results... 4 1.3. Facilities and Accreditations... 5 2. 47 CFR PART 15C AND RSS-210 REQUIREMENTS... 6 2.1. Number

More information

For. Tzone FCC ID: FCC Part Description: Product TZ-BT04. Report to Tested By: Manager STR I

For. Tzone FCC ID: FCC Part Description: Product TZ-BT04. Report to Tested By: Manager STR I FCCC Part 15C Measurement and Test For Report Tzone Digitall Technology Co.., LTD 16D, Haiying Building, South of Caitian Road, Futiann District, Shenzhen China FCC ID: 2AKSQTZBT04 FCC Rule(s): Product

More information

Version TEST REPORT NO. DATE DESCRIPTION

Version TEST REPORT NO. DATE DESCRIPTION Version NO. DATE DESCRIPTION HCTR1302FR13 February 14, 2013 - First Approval Report - Additional Model Name Page 2 of 25 Table of Contents 1. GENERAL INFORMATION... 4 2. EUT DESCRIPTION... 4 3. TEST METHODOLOGY...

More information

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD FCC PART 15.249 MEASUREMENT AND TEST REPORT FOR Guangzhou Walkera Technology CO., LTD Taishi Industrial Park, Yuwoto Town, Panyu District, 511475 Guangzhou, China. FCC ID: S29WK-2801PRO Report Concerns:

More information

FCC REPORT. Lightcomm Technology Co., Ltd.

FCC REPORT. Lightcomm Technology Co., Ltd. FCC REPORT Report No.: GTS201608000267E01 Applicant: Lightcomm Technology Co., Ltd. Address of Applicant: RM 1808 18/F FO TAN INDUSTRIAL CENTRE NOS. 26-28 AU PUI WAN STREET FO TAN SHATIN NEW TERRITORIES

More information

FCC RF TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

FCC RF TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FCC RF TEST REPORT APPLICANT : Homewerks Worldwide, LLC PRODUCT NAME : Ventilating Bath fan with bluetooth speaker MODEL NAME : 7130-06-BT TRADE NAME : Home Net Werks BRAND NAME : Home Net Werks FCC ID

More information

FCC RF TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

FCC RF TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FCC RF TEST REPORT APPLICANT : Homewerks Worldwide, LLC PRODUCT NAME : Ventilating Bath fan with bluetooth speaker MODEL NAME : 7130-06-BT TRADE NAME : Home Net Werks BRAND NAME : Home Net Werks FCC ID

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3 Revision History Version Issue Date Revisions Rev. 01 June 30, 2014 First edition TABLE OF CONTENTS 1 GENERAL INFORMATION... 3 1.1 Identification of the Testing Laboratory... 3 1.2 Identification of the

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. DEI Sales Inc. dba Definitive Technology. Model Number: STUDIO SLIM SUBWOOFER

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. DEI Sales Inc. dba Definitive Technology. Model Number: STUDIO SLIM SUBWOOFER FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of DEI Sales Inc. dba Definitive Technology 3.1 Home Theater Sound Bar and Wireless Subwoofer System Model Number: STUDIO SLIM SUBWOOFER FCC ID: IPUSTUSLIMSUB

More information

Jul. 16, Jun. 04, Shenzhen. Tel:(86-755)

Jul. 16, Jun. 04, Shenzhen.   Tel:(86-755) Test Report FCC ID.: MTi160413E004 Date of issue: Jul. 16, 2016 Sample Description: Wireless POS Terminal Model(s): G3 Applicant: Shenzhen Xinguodu Technology Co., Ltd. Address: 17/A, Jinsong Building

More information

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above. FCC REPORT Applicant: Address of Applicant: Manufacturer/Factory: Address of Manufacturer/Factory: Guangzhou Smamao Electronic Technology Co.,Ltd Room 811, Building 8, No.315, Central City, Middle Road,

More information

FCC PART 15 SUBPART C TEST REPORT FCC PART

FCC PART 15 SUBPART C TEST REPORT FCC PART FCC PART 15 SUBPART C TEST REPORT FCC PART 15.249 Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 Report Reference No.: CTL1508212421-WF Compiled by: ( position+printed

More information

TEST REPORT FCC PART Jacky Chen (File administrators) Allen Wang (Test Engineer) Tracy Qi (Manager)

TEST REPORT FCC PART Jacky Chen (File administrators) Allen Wang (Test Engineer) Tracy Qi (Manager) TEST REPORT FCC PART 15.249 Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 Report Reference No.... : CTL1606222365-WF Compiled by: ( position+printed name+signature)

More information

TEST REPORT. Issued for: ShenZhen MYGT Co.,LTD D3 Tongfuyu Industrial Area Community of Shajing Town, Baoan, Shenzhen, China.

TEST REPORT. Issued for: ShenZhen MYGT Co.,LTD D3 Tongfuyu Industrial Area Community of Shajing Town, Baoan, Shenzhen, China. TEST REPORT FCC ID: 2AMKEMY-C11 Product: Wireless Gamepad Model No.: MY-C11 Additional Model No.: TKGC01 Trade Mark: N/A Issued Date: Oct. 16, 2017 Issued for: ShenZhen MYGT Co.,LTD D3 Tongfuyu Industrial

More information

FCC CERTIFICATION TEST REPORT

FCC CERTIFICATION TEST REPORT Report No:DDT-RE120176 Issued Date: 2013/01/05 FCC CERTIFICATION TEST REPORT FOR Applicant : AliMed Inc. Address : 297 High St Dedham Ma 02026 Equipment under Test : Alert transmitter Model No : #712716

More information

TABLE OF CONTENTS. Report No.: SZ E01 1. GENERAL INFORMATION... 3

TABLE OF CONTENTS. Report No.: SZ E01 1. GENERAL INFORMATION... 3 TABLE OF CONTENTS 1. GENERAL INFORMATION... 3 1.1 EUT Description... 3 1.2 Test Standards and Results... 3 1.3 Test Equipments Used... 4 1.4 Facilities and Accreditations... 4 1.4.1 Facilities... 4 1.4.2

More information

ITL Page 2 of 71 Report No.:

ITL Page 2 of 71 Report No.: ITL Page 1 of 71 Report No.: 12092752 TEST REPORT Applicant: Address of Applicant: Harman International Industries, Incorporated 8500 Balboa Blvd, Northridge, CA 91329, United States Manufacturer: Address

More information

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ADPC-G6 Report No.: LCS E

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ADPC-G6 Report No.: LCS E 2) Sequence of testing 30 to 1 GHz Setup: --- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer. --- If the EUT is a tabletop system, a

More information

APPLICATION CERTIFICATION FCC Part 15C&RSS-247 On Behalf of Sunwoda Electronic Co., Ltd. Active stylus. Model No.: SPEN-HP-03

APPLICATION CERTIFICATION FCC Part 15C&RSS-247 On Behalf of Sunwoda Electronic Co., Ltd. Active stylus. Model No.: SPEN-HP-03 Page 1 of 59 APPLICATION CERTIFICATION FCC Part 15C&RSS-247 On Behalf of Sunwoda Electronic Co., Ltd. Active stylus Model No.: SPEN-HP-03 FCC ID: 2ABWESPEN-HP-03 IC: 23012-SPENHP03 Prepared for : Sunwoda

More information

REPORT REVISION HISTORY...

REPORT REVISION HISTORY... Reference No.: WTS17S0579239E Page 2 of 39 2 Contents Page 1 COVER PAGE... 1 2 CONTENTS... 2 3 REPORT REVISION HISTORY... 3 4 GENERAL INFORMATION... 4 4.1 GENERAL DESCRIPTION OF E.U.T.... 4 4.2 DETAILS

More information

RF TEST REPORT for Intentional Radiator No SHA-001

RF TEST REPORT for Intentional Radiator No SHA-001 RF TEST REPORT for Intentional Radiator No. 160600514SHA-001 Applicant : Shanghai Ruipai Intelligent Technology Co.,Ltd. B105, Building 9, Wusong Science Park, No.69 Tieshan Rd., Baoshan District, Shanghai,

More information

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR 802.11g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD MODEL NUMBER: BCM94312HMGB REPORT NUMBER: 09U12439-2 ISSUE DATE:

More information

[ Contents ] KCTL-TIR /0. Report No.: KCTL16-SFR0039

[ Contents ]   KCTL-TIR /0. Report No.: KCTL16-SFR0039 [ Contents ] 1. Client information... 3 2. Laboratory information... 4 3. Description of E.U.T.... 5 3.2 General description... 5 3.3 Test frequency... 6 3.4 Test Voltage... 6 4. Summary of test results...

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. ION Audio, LLC. Portable Karaoke PA speaker with vocal effects

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. ION Audio, LLC. Portable Karaoke PA speaker with vocal effects FCC PART 15C TEST REPORT FOR CERTIFICATION Behalf of ION Audio, LLC Portable Karaoke PA speaker with vocal effects Model Number: ipk3 KARAOKE STAR PLUS FCC ID: 2AB3E-IPK3 Prepared for: Prepared By: ION

More information

FCC PART 15C & RSS 247 TEST REPORT

FCC PART 15C & RSS 247 TEST REPORT FCC PART 15C & RSS 247 TEST REPORT No. I18N01184-WLAN for Spectralink Corp GSM Quad-band/UMTS five-band/lte/ca Mobile phone 9640 with Hardware Version: PIO Software Version: vf03 FCC ID: IYG96XX IC: 2128B-96XX

More information

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR The Apple ipad is a tablet device with multimedia functions (music, application support, and video), 802.11a/b/g/n

More information

TEST REPORT. Issued for: RUIMA INTERNATIONAL(HK)INDUSTRIAL CO.,LIMITED NO.19 Ruixiang Road, Xinhua Industrial Zone, Huadu District, Guangzhou China

TEST REPORT. Issued for: RUIMA INTERNATIONAL(HK)INDUSTRIAL CO.,LIMITED NO.19 Ruixiang Road, Xinhua Industrial Zone, Huadu District, Guangzhou China TEST REPORT FCC ID: 2AHSJRM-626B Product: Boombox Speaker Model No.: RM-626 Additional Model: STREET HOPPER 6, CANNON 6 Trade Mark: RUIMA Issued Date: Aug. 04, 2016 Issued for: RUIMA INTERNATIONAL(HK)INDUSTRIAL

More information

TEST REPORT. Reference No... : WTS16S E FCC ID... : SJ8-UDR777HD. Applicant... : RDI Technology Shenzhen Co., Ltd.

TEST REPORT. Reference No... : WTS16S E FCC ID... : SJ8-UDR777HD. Applicant... : RDI Technology Shenzhen Co., Ltd. TEST REPORT Reference No.... : WTS16S0449305E FCC ID... : SJ8-UDR777HD Applicant... : RDI Technology Shenzhen Co., Ltd. Address... : Building C1, Xintang Industrial Park East Baishixia, Fuyong, Baoan,

More information

FCC PART TEST REPORT. Weccan Industrial Limited

FCC PART TEST REPORT. Weccan Industrial Limited FCC PART 15.249 TEST REPORT For Weccan Industrial Limited Rm209, 2/F, Building W1-A, No.34 Gaoxin South 4th St Hi-Tech Industrial Park, Nanshan District, Shenzhen China FCC ID: Z3CWECCANDRONE Report Type:

More information

A Test Lab Techno Corp. Report Number:1410FR27

A Test Lab Techno Corp. Report Number:1410FR27 Mode 5: IEEE 802.11n 2.4GHz 40MHz Link Mode 2422 2437 2452 Page 41 of 85 9 Out of Band Conducted Emissions Measurement 9.1. Limit In any 100 khz bandwidth outside the frequency band in which the spread

More information

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9 FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 REPORT NUMBER: 15U22448-E1V4 ISSUE DATE: 3/7/2016 Prepared for Verizon Online

More information

FCC Test Report. Report No.: PTCDQ FC01

FCC Test Report. Report No.: PTCDQ FC01 Page 1 of 63 FCC Test Report Report No.: PTCDQ04170450501-FC01 FCC ID : 2AL2XW801 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : WIFI DoorBell BRAND NAME : EASTIC MODEL NAME : W801, W802,

More information

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated Page 1 of 17 FCC 15.209 & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report for A Acer Incorporated 8F., No.88, Sec. 1, Xintai 5th Rd., Xizhi, New Taipei City 22181, Taiwan (R.O.C) Product

More information

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR Dolphin CT50 MODEL NUMBER: CT50LFN IC ID: 1693B-CT50LFN REPORT NUMBER: 15U20259-E6 ISSUE DATE: JUNE 08, 2015 Prepared

More information

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B. Test Standards: FCC Part 15B Measurement and Test Report Product Description: Tested Model: Report No.: For GlobTek, Inc. 186 Veterans Dr. Northvale, NJ 07647 USA FCC Part 15 Subpart B Power Supply GT-93020-0324

More information

FCC 47 CFR PART 15 SUBPART C AND ANSI C63.10:2013 TEST REPORT

FCC 47 CFR PART 15 SUBPART C AND ANSI C63.10:2013 TEST REPORT FCC 47 CFR PART 15 SUBPART C AND ANSI C63.10:2013 TEST REPORT For ZigBee Module Model: MD1000 Trade Name: Billion Issued for Billion Electric Co., Ltd. 8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist.,

More information

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations Model numbers: HT130022 Rev. B. December 17, 2002 Manufacturer: HQ, Inc. 210 9th Steet Drive Palmetto, FL 34221

More information

Dongguan Lingjie Electronics & Technology Co., Ltd. David Huang Checked By

Dongguan Lingjie Electronics & Technology Co., Ltd. David Huang Checked By RF TEST REPORT Report No.: Supersede Report No.: N/A Applicant Product Name Main Model Serial Model Dongguan Lingjie Electronics & Technology Co., Ltd Wireless Mouse I886 N/A Test Standard FCC Part 15.249:

More information

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer)

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer) FCC Test Report FCC Rule(s): Applicant: Product Name: Model: FCC ID: Report No.: FCC Part 15 Subpart B Neets A/S Touch Panel 313-0001(Touch Panel-7B) 2AM35-313-0001 ZKS170600143E Tested Date: 2017-07-06

More information

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C. FCC TEST REPORT REPORT NO.: RF991014E04 MODEL NO.: M-R0018 FCC ID: JNZMR0018 RECEIVED: Oct. 14, 2010 TESTED: Oct. 19, 2010 ISSUED: Oct. 22, 2010 APPLICANT: LOGITECH FAR EAST LTD. ADDRESS: #2 Creation Rd.

More information

FCC Report for Parts ,

FCC Report for Parts , FCC Report for Parts 15.247, 15.7 Product name Applicant FCC ID : WSN Node : Evalan : 2AK2M-EVAWSN-N15 Test report No. : 1100161 Ver 1.00 Laboratory information Accreditation Telefication is designated

More information

Shenzhen Hong Puya Technology Co., Ltd.

Shenzhen Hong Puya Technology Co., Ltd. Shenzhen United Testing Technology Co., Ltd. Report No.: UNI-1410102-01 FCC TEST REPORT Prepared For : Product Name: Model : Prepared By : Shenzhen Hong Puya Technology Co., Ltd. Bluetooth stereo4.0 S7720;

More information

TEST REPORT. For. Model Name : Maestro T4HU1608, Maestro T4HUXXXX (X is 0 to 9) Issued by : Most Technology Service Co., Limited.

TEST REPORT. For. Model Name : Maestro T4HU1608, Maestro T4HUXXXX (X is 0 to 9) Issued by : Most Technology Service Co., Limited. TEST REPORT For Applicant : Address : Product Name : Tech4home, Lda Rua de Fundoes, No.151, 3700-121 Sao Joao da Madeira, Portugal Remote Control Unit Model Name : Maestro T4HU1608, Maestro T4HUXXXX (X

More information

TEST REPORT SZEM CR

TEST REPORT SZEM CR No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 Email: ee.shenzhen@sgs.com Application No.:

More information

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3 FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3 ISSUE DATE: NOVEMBER 22, 2004 Prepared for WJ COMUNICATIONS

More information

TEST REPORT FCC PART

TEST REPORT FCC PART TEST REPORT FCC PART 15.247 Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: ctl@ctl-lab.com Report Reference No.... : CTL1805164013-WF02 Compiled by: ( position+printed name+signature)

More information

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8 Page 1 of 19 APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 Prepared for : Carewell Electric Technology (Zhongshan) Co., Ltd.

More information

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR DUAL RADIO OUTDOOR ACCESS POINT MODEL NUMBER: AP-ONE FCC ID: SWX-AP1R2

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR DUAL RADIO OUTDOOR ACCESS POINT MODEL NUMBER: AP-ONE FCC ID: SWX-AP1R2 FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR DUAL RADIO OUTDOOR ACCESS POINT MODEL NUMBER: AP-ONE REPORT NUMBER: 04U3091-1 ISSUE DATE: JANUARY 07, 2005 Prepared for UBIQUITI NETWORKS 1111

More information

TEST REPORT. Issued for:

TEST REPORT. Issued for: TEST REPORT FCC ID: 2ALPZ- AA00277W Product: Handsfree car kit with FM Transmitter Model No.: AA00277W Additional Model: AA00277G Trade Mark: N/A Report No.: TCT170331E007 Issued Date: Apr. 14, 2017 Issued

More information

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS Page 1 of 49 TESTT REPORT For Applicant : ACOUSTMAX INTERNATIONAL CO.., LTD Unit D16/F Cheuk Nang Plaza 250 Hennessy Road Address : WanchaiHongKong Product Name : Monster GLO Model Name : MNGLO-S, MNGLO-L,MNGLO-M,MNGLO-Mini

More information

Report No.: HCT-R-1507-F015-2 Model: SW100 Page 2 of 52. Version TEST REPORT NO. DATE DESCRIPTION

Report No.: HCT-R-1507-F015-2 Model: SW100 Page 2 of 52. Version TEST REPORT NO. DATE DESCRIPTION Report No.: HCT-R-1507-F015-2 Model: SW100 Page 2 of 52 Version TEST REPORT NO. DATE DESCRIPTION HCT-R-1507-F015 July 10, 2015 - First Approval Report HCT-R-1507-F015-1 July 20,2015 - Updated the KDB version.

More information

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards: Medtronic MiniMed TEST REPORT FOR GST3 Glucose Sensor Transmitter, MMT-7763A Tested To The Following Standards: FCC Part 15 Subpart C Sections 15.247 Date of issue: October 31, 2013 This test report bears

More information

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station Page 20 of 51 Pages 7.5. Conducted spurious emission 7.5.1. Requirements: Clause 15.247(d). In any 100 khz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Superior communications. Wireless charger. Model Number: Additional Model: 06122

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Superior communications. Wireless charger. Model Number: Additional Model: 06122 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Superior communications. Wireless charger Model Number: 06121 Additional Model: 06122 FCC ID: YJW06121 Prepared for: Superior communications. 5027

More information

FCC RF TEST REPORT No SHA-001

FCC RF TEST REPORT No SHA-001 Page 1 of 41 FCC RF TEST REPORT No. 180300344SHA-001 Applicant : Stanley Black & Decker, Inc. 400 Executive Blvd S, Southington, CT 06489 USA Manufacturer : Northwest Instrument Inc. 330 Waterloo Valley

More information

TEST REPORT. Shenzhen, PRC.

TEST REPORT. Shenzhen, PRC. TEST REPORT Reference No.... : WTS16S0449309E FCC ID... : SJ8-UDRC57 Applicant... : RDI Technology Shenzhen Co., Ltd. Address... : Building C1, Xintang Industrial Park East Baishixia, Fuyong, Baoan, Shenzhen,

More information

FCC RADIO TEST REPORT FCC 47 CFR PART 15 SUBPART C

FCC RADIO TEST REPORT FCC 47 CFR PART 15 SUBPART C FCC RADIO TEST REPORT FCC 47 CFR PART 15 SUBPART C Test Standard FCC ID Trade name Product name Model No. Test Result FCC Part 15.249(a) WHBARUTR AUDI UTR (Universal Traffic Recorder) UTR (Universal Traffic

More information

FCC Part 22H & 24E Measurement and Test Report

FCC Part 22H & 24E Measurement and Test Report FCC Part 22H & 24E Measurement and Test Report For Shenzhen Concox Information Technology Co., Ltd Floor 4th, Building B, Gaoxinqi Industrial Park, Liuxian 1st Road, District 67, Bao an, Shenzhen, China

More information

FCC Part 15C Test Report

FCC Part 15C Test Report FCC Part 15C Test Report FCC ID: 2AL5W-DFIT Product Name: Trademark: Model Name : Prepared For : Address : Prepared By : smart watch N/A Dfit D8, D8S, D21, DF23, DF30, DB01, DB02, DB03, DB04, DB05, DB06,

More information

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR CELLULAR PHONE WITH BLUETOOTH AND WLAN RADIOS MODEL NUMBER: A1778 REPORT NUMBER: 16U23328-E2V5

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed Seite 2 von 24 Page 2 of 24 TEST SUMMARY 5.1.1 FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed 5.1.2 99% BANDWIDTH RESULT: Passed 5.1.3 SPURIOUS EMISSION RESULT: Passed 5.2.1 SPURIOUS EMISSION RESULT: Passed

More information

DIRECTORY. 1. General Information Applicant Manufacturer Description of EUT Facilities and Accreditations...

DIRECTORY. 1. General Information Applicant Manufacturer Description of EUT Facilities and Accreditations... DIRECTORY. General Information... 4. pplicant... 4.2 Manufacturer... 4.3 Description of EUT... 4 2. Facilities and ccreditations... 5 2. Test Facility... 5 2.2 Environmental Conditions... 5 2.3 Measurement

More information

FCC TEST REPORT. For EASYACC TECHNOLOGY CO., LIMITED Wireless speaker

FCC TEST REPORT. For EASYACC TECHNOLOGY CO., LIMITED Wireless speaker FCC ID: 2AJUJ-DP300 Page1 of 46 Report No.: R0217060058W FCC TEST REPORT For EASYACC TECHNOLOGY CO., LIMITED Wireless speaker Model No.: DP300 Prepared For : EASYACC TECHNOLOGY CO., LIMITED Address : UNIT

More information

FCC 47 CFR PART 22, PART 24, PART 27 TEST REPORT

FCC 47 CFR PART 22, PART 24, PART 27 TEST REPORT FCC 47 CFR PART 22, PART 24, PART 27 TEST REPORT For DVR S597 Model: E-006-0597 Brand: N/A Test Report Number: C181105Z01-RP2 Issued for PeopleNet Communications Corporation 4400 Baker Road, Minnetonka,

More information

Description of Test Facility

Description of Test Facility Description of Test Facility Name: Address: Intertek Testing Services Limited Shanghai Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China FCC Registration Number: 236597 IC Assigned

More information

MEASUREMENT REPORT FCC PART & IC RSS-247 Bluetooth v4.1

MEASUREMENT REPORT FCC PART & IC RSS-247 Bluetooth v4.1 MRT Technology (Suzhou) Co., Ltd Report No.: 1512RSU00101 Phone: +86-512-66308358 Report Version: V03 Fax: +86-512-66308368 Issue Date: 04-21-2016 Web: www.mrt-cert.com MEASUREMENT REPORT FCC PART 15.247

More information

FCC 47 CFR PART 15 SUBPART C AND ANSI C63.10:2013 TEST REPORT

FCC 47 CFR PART 15 SUBPART C AND ANSI C63.10:2013 TEST REPORT FCC 47 CFR PART 15 SUBPART C AND ANSI C63.10:2013 TEST REPORT For AB1602 Bluetooth 4.2 Module Model: AB1602 Trade Name: Airoha Issued for Airoha Technology Corp. 5F.,No.6-5,Dusing Road, Hsinchu Science

More information

FCC & IC TEST REPORT for Bluetooth Device No SHA-001

FCC & IC TEST REPORT for Bluetooth Device No SHA-001 Page 1 of 41 FCC & IC TEST REPORT for Bluetooth Device No. 161100632SHA-001 Applicant : Manufacturer : Product Name : SHENZHEN DNS INDUSTRIES CO., LTD. 23/F Building A, Shenzhen International Innovation

More information

Shenzhen Hong Puya Technology Co., Ltd.

Shenzhen Hong Puya Technology Co., Ltd. FCC TEST REPORT Prepared For : Product Name: Model : Prepared By : Shenzhen Hong Puya Technology Co., Ltd. Bluetooth stereo4.0 S7720; S111; S222; S7730; S777 Shenzhen United Testing Technology Co., Ltd.

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10 FCC ID: AK8SRSXB10 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Sony Corporation Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10 Prepared for : Sony Corporation 1-7-1 Konan Minato-ku Tokyo, 108-0075

More information