Relays, Timers, Interface Modules, Sockets and Accessories Catalogue. The power in relays and timers since 1954

Size: px
Start display at page:

Download "Relays, Timers, Interface Modules, Sockets and Accessories Catalogue. The power in relays and timers since 1954"

Transcription

1 Relays, imers, Interface Modules, Sockets and Accessories Catalogue he power in relays and timers since 954

2

3 he power in relays ISO 900 ISO 400 Our four factories produce over 50,000 relays every day, using machines which have been designed and built in-house by our own team of technicians, who are experts in their own right in production techniques and industrial automation. Finder s 0,000 different products represent one of the most extensive product lines available on the market. hey are the result of specialization across a variety of relay types: step relays, light dependent relays, miniature and sub-miniature p.c.b relays, plug-in general purpose and power relays, relay interface modules, timers relay sockets and accessories. Finder has always followed a product value strategy aimed at constantly increasing quality. Product line reliability has been recognized through approvals by international standards organizations such as the ABS, BBJ, BEAB, CSA, DEMKO, FIMKO, GERMANISCHER LLOYD, GOS, IMQ, IRAM, LLOYD S REGISER, NEMKO, LCIE, RINA, SEV, SEMKO, V, L and VDE, and through CE certification. As important as these quality approvals are, Finder considers it no more important than its partnerships with customers, who are able to value the quality of its products and after-sales service. For up-to-date information regarding Finder, visit our web site at

4

5 Fax-back form FINDER S.p.A. Via Drubiaglio, ALMESE (O) IALY el.+39/ Fax +39/ Export@findernet.com For further information on the following, please complete and return: Name:... Position:... Company:... Address:... Postcode: elephone:... Fax:... Finder customer: YES NO PRICE LIS CAALOGE ON CD-ROM (includes DXF files for AOCAD R3) SALES ENGINEER O VISI

6 Contents 30 Series...Page 4 Subminiature D.I.L. Relays.5 A 34 Series...Page 6 ltra-slim P.C.B. Relays A 36 Series...Page 3 Miniature Relays 0 A 40 Series...Page 6 Miniature P.C.B. Relays A 95 Series...Page 3 Sockets and Accessories 4 Series...Page 6 Low-Profile P.C.B. Relays A 95 Series...Page 9 Sockets and Accessories 43 Series...Page 30 Low-Profile P.C.B. Relays 0 A 95 Series...Page 33 Sockets and Accessories 44 Series...Page 34 Miniature P.C.B. Relays 6-0 A 95 Series...Page 37 Sockets and Accessories 45 Series...Page 40 Miniature P.C.B. Relays 6 A 56 Series...Page 53 Miniature Power Relays A 96 Series...Page 58 Sockets and Accessories 60 Series...Page 60 General Purpose Relays 0 A 90 Series...Page 65 Sockets and Accessories 6 Series...Page 70 Power Relays 6 A 9 Series...Page 79 Sockets and Accessories 65 Series...Page 8 Power Relays 0-30 A 9 Series...Page 85 Modular AO-OFF-ON Relays 0 A 38 Series...Page 87 Relay Interface Module A 48 Series...Page 94 Relay Interface Modules A 58 Series...Page 99 Relay Interface Module 7-0 A 55 Series...Page 43 Miniature General Purpose Relays 7-0 A 94 Series...Page 48 Sockets and Accessories

7 Contents 7 Series...Page 03 Monitoring Relay 0 A 3 Series...Page 5 Electronic Step Relays 0-6 A Series...Page 7 Modular imers 6 A 4 Series...Page 55 Electronic Staircase imers 6 A Series...Page Miniature Plug-in imers 7-0 A 0 Series...Page 58 Modular Step Relays 6 A Series...Page 4 Sockets and Accessories Series...Page 6 imer Modules Series...Page 30 Sockets and Accessories Series...Page 6 Modular Monostable Relays 0 A Series...Page 3 Modular imers 5-8 A 6 Series...Page 64 Step Relays 0 A Series...Page 40 Plug-in imers 5-8 A 90 Series...Page 43 Sockets and Accessories 7 Series...Page 67 Step Relays 0 A Series...Page 44 Light Dependent Relays - 6 A i General echnical Information... Page Series...Page 46 Modular Light Dependent Relays 6 A Series......Page 49 ime Switches 6 A 6 7 i

8 30 Series - Subminiature D.I.L. Relays.5 A 30 - Sub miniature relay - Low level switching capability - Sensitive DC coil, 00mW - Wash tight: R III Low consumption -P.C.B. mounting Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) Copper side view CO.5/ 5/ /0.3/ 0 (0./) AgNi+Au /0. see table page 5 /0.35 N /0.05 N / /. kv/ R III GOS C S

9 30 Series - Subminiature D.I.L. Relays.5 A ORDERING INFORMAION 30 Example: a 30 series P.C.B. relay with CO contacts, with coil rated at V sensitive DC. A B C D Series ype = P.C.B. No. of poles = pole,.5 A Coil version 7 = Sensitive DC Coil voltage see coil specifications A: Contact material 0 = Standard AgNi + Au (5µm) B: Contact circuit 0 = CO D: Special versions 0 = Wash tight (R III) C: Options = None ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 5 rated impulse withstand voltage kv. pollution degree overvoltage category I OHER DAA BONCE IME: NO/NC ms /3 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/0 POWER LOS O HE ENVIRONMEN without contact current W 0. with rated current W 0.4 RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 COIL SPECIFICAIONS DC VERSION DAA (0. W sensitive) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , ,50 4. R 30 DC N AMBIEN EMPERARE ( C) Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 5

10 34 Series - Slim Electromechanical Relays 6 A 34 - ltra-slim, 5 mm wide - Sensitive DC coil, 70mW - 6/8 mm clearance/creepage distance - 6kV (./50 µs) between coil and contacts mm wide -P.C.B. mounting * For 400 V applications, where requirements for pollution degree are met. Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) Copper side view CO 6/0 50/400*, /0./ (/0) AgNi /0.7 (0.7.5) N /0.4 N /0.05 N / /3 4 kv/3 6 (8 mm), R II GOS C S

11 34 Series - Slim Solid State Relay (SSR) 0. - A - ltra-slim, 5 mm wide - High switching speed and endurance - Silent switching Switching current A - 4 V DC -P.C.B. mounting - Switching current 0.A - 48 V DC -P.C.B. mounting A A input output input output Copper side view Copper side view Output circuit Rated current/maximum peak current (0 ms) A Rated voltage/maximum blocking voltage V DC Switching voltage range V DC Minimum switching current ma Max OFF-state leakage current µa Max ON-state voltage drop V Input circuit Nominal voltage V DC Operating range V DC Control current ma Release voltage V DC Impedance Ω echnical data Operate/release time µs Dielectric strength between input/output V Ambient temperature range C Environmental protection Approvals: (according to type) /0 0./0.5 4/33 48/ ,00,300 3,00, /80 8/90,500, R III R III 7

12 34 Series - Slim Relays ORDERING INFORMAION 34 ELECROMECHANICAL RELAY Example: a 34 series slim electromechanical relay, CO - 6 A, with 4 V sensitive DC coil. A B C D Series ype 5 = Electromechanical type No. of poles = pole, 6 A Coil version 7 = Sensitive DC Coil voltage see coil specifications A: Contact material 0 = Standard AgNi 4 = AgSnO 5 = AgNi + Au B: Contact circuit 0 = CO 3 = NO D: Special versions 0 = Flux proof (R II) 9 = Flat version C: Options = None Only combinations in the same row are possible Preferred versions coil version A B C D 34.5 sens. DC All versions coil version A B C D 34.5 sens. DC sens. DC SOLID SAE RELAY Example: a 34 series SSR relay, A, with 4VDC supply. 3 4 Series ype 8 = SSR type Output = NO Input circuit see input specifications Output circuit 904 = A - 4 VDC 7048 = 0.A - 48 VDC Note: All technical data are referred using the relay directly on PCB or PCB socket mounted type 93.. If the relay is use with 35 mm rail socket types 93.0 or 93.5, referrer to the technical data of 38 Series, page 87 POSSIBLE OPIONS 8 5 Ø Ø Copper side view Option = xxx.x09 8 8

13 34 Series - Slim Relays ELECROMECHANICAL RELAY ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4 kv) SRGE (according to EN ) level 3 ( kv) OHER DAA BONCE IME: NO/NC ms /6 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/5 POWER LOS O HE ENVIRONMEN without contact current W 0. with rated current W 0.5 RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 34 CONAC SPECIFICAIONS F 34 CYCLES Electrical life vs AC load. COIL SPECIFICAIONS DC VERSION DAA LOAD RAED CRREN (A) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , ,700 3 H 34 DC BREAKING CRREN (A) Breaking capacity in DC load. When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. R 34 DC N DC VOLAGE (V) AMBIEN EMPERARE ( C) 80 Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 9

14 34 Series - Slim Relays 34 SOLID SAE RELAY ECHNICAL DAA OHER DAA POWER LOS O HE ENVIRONMEN without output current W 0.7 with rated current W 0.4 INP SPECIFICAION DC VERSION DAA Nominal Input Operating range Release Control voltage code voltage current N min max I at N V V V V ma OP SPECIFICAION L 34/A L 34/0.A 3.5 SWICHING CRREN AMBIEN EMPERARE ( C) ype 34.8 (A-4VDC) Switching current vs ambient temperature SWICHING CRREN AMBIEN EMPERARE ( C) ype 34.8 (00mA-48VDC) Switching current vs ambient temperature 0

15 V~ 93 Series - Sockets and Accessories for 34 Series Relays Approvals (according to type): C GOS S 75.6 Relay type 34.5, 34.8 Screw terminal socket: 35 mm (EN 500) mounting Supply voltage Relay type Socket type C/DC xx C/DC xx C/DC xx C/DC xx C/DC xx C/DC xx C/DC* xx0 or xxxx * 0 40 C* xx0 or xxxx * 6 VDC xx VDC xx VDC xx0 or xxxx VDC xx VDC xx0 or xxxx Approvals (according to type): GOS 75.6 Relay type 34.5, 34.8 Screwless terminal socket: 35 mm (EN 500) mounting Supply voltage Relay type Socket type C/DC xx C/DC xx C/DC xx C/DC xx C/DC* xx0 or xxxx * 0 40 C* xx0 or xxxx * VDC xx VDC xx0 or xxxx VDC xx0 or xxxx * Leakage current suppression Relay type 34.5/34.8 Colour BLE P.C.B. sockets with retaining and release clip Approvals (according to type): GOS - RAED LES: 6A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C Retaining and release clip use: Copper side view

16 93 Series - Sockets and Accessories for 34 Series Relays 34 ACCESSORIES 0-way jumper link for 38 series RAED LES: 36 A - 50 V Approvals (according to type): C S Plastic separator hickness mm, required at the start and the end of a group of interfaces. Can be used for visual separation group, must be used for: - protective separation of different voltages of neighbouring PLC interfaces according to VDE protection of cut jumper links Sheet of marker tags (64 tags): 6x0 mm

17 36 Series - Miniature P.C.B. Relays 0 A - P.C.B. mount - Sugar cube - Sensitive DC coil - Wash tight: R III - Basic insulation VDE Sugar cube - CO -P.C.B. mounting - Sugar cube - NO -P.C.B. mounting Ø Ø.5 Copper side view Copper side view Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/sens. DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Envirommental protection Approvals: (according to type) CO NO 0/5 0/5 50/50 50/50,500, /0.3/0. 0/0.3/ (5/00) 500 (5/00) AgCdO AgCdO /0.36 /0.36 (0.75.5) N (0.75.5) N /0.4 N /0.4 N /0. N /0. N /0 0 6 / /3 7/.5 kv/.5 kv/ 4 4,000, R III R III GOS C S GOS 3

18 36 Series - Miniature P.C.B. Relays 0 A ORDERING INFORMAION 36 Example: a 36 series miniature P.C.B. relay, CO - 0 A contacts, with V DC coil. A B C D Series ype = P.C.B. No. of poles = pole, 0 A Coil version 9 = DC Coil voltage see coil specifications A: Contact material 0 = Standard AgCdO B: Contact circuit 0 = CO 3 = NO D: Special versions 0 = Wash tight (R III) C: Options 0 = None ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv.5 pollution degree overvoltage category II OHER DAA BONCE IME: NO/NC ms /6 (CO version) / (NO version) 4

19 36 Series - Miniature P.C.B. Relays 0 A CONAC SPECIFICAIONS F 36 CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. H 36 DC BREAKING CRREN (A) DC VOLAGE (V) Breaking capacity in DC load. When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. 36 COIL SPECIFICAIONS DC VERSION DAA R 36 Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , N AMBIEN EMPERARE ( C) 80 Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 5

20 .5 =.4.5 CERIFICACION DE CONFORMIDAD DE LA FABRICACION =.4.5 =.4 40 Series - Miniature P.C.B. Relays A 40 - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./50 µs) between coil and contacts - Ambient temperature +85 C - Sockets and accessories: see 95, 99 and 86 series - R III (wash tight) version available pole, 0 A mm pinning - P.C.B. / for use with 95 series sockets - pole, 0 A -5 mm pinning - P.C.B. / for use with 95 series sockets - pole, 8 A -5 mm pinning - P.C.B. / for use with 95 series sockets = 7.5 = 7.5 = * For 400 V applications, where requirements for pollution degree are met. Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC/sens. DC (50 Hz)/W/W Operating range AC DC/sens. DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Envirommental protection Approvals: (according to type) Copper side view Copper side view Copper side view CO CO CO 0/0 0/0 8/5 50/400* 50/400* 50/50,500,500, /0.3/0. 0/0.3/0. 8/0.3/ (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi /0.65/0.5./0.65/0.5./0.65/0.5 (0.8.) N (0.8.) N (0.8.) N (0.73.5) N /( ) N (0.73.5) N /( ) N (0.73.5) N /( ) N 0.8 N /0.4 N 0.8 N /0.4 N 0.8 N /0.4 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /3 - (/4 sens.) 7/3 - (/4 sens.) 7/3 - (/4 sens.) 4 kv/3 4 kv/3 4 kv/ 6 (8mm) 6 (8mm) 6 (8mm),000,000, R I R I R I BEAB GOS RINA C S

21 .5 CERIFICACION DE CONFORMIDAD DE LA FABRICACION =.4 40 Series - Miniature P.C.B. Relays A - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./50 µs) between coil and contacts - Ambient temperature +85 C - Sockets and accessories: see 95, 99 and 86 series - R III (wash tight) version available xx pole, 6 A -5 mm pinning - P.C.B. / for use with 95 series sockets - Bistable version ( coil) - P.C.B. / for use with 95 series sockets 4 () 4 (4) Bistable version ( coil) types: () * For 400 V applications, where requirements for pollution degree are met. ** With the AgSnO material the maximum peak current is 00 A - 5 ms. on NO contact = Copper side view For wiring diagrams see page Contact specifications Contact configuration Rated current/maximum peak current A CO 6/30** Rated voltage/maximum switching voltage V AC 50/400* See relays Rated load in AC 4, Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A 6/0.3/ Minimum switching load Standard contact material Coil specifications mw (V/mA) 500 (0/5) AgCdO Nominal voltage ( N ) V AC (50/60 Hz) V DC ***See below Rated power AC/DC/sens. DC (50 Hz)/W/W./0.65/0.5.0/.0/ Operating range AC (0.8.) N (0.8.) N DC/sens. DC (0.73.5) N /(0.8.5) N (0.8.) N / Holding voltage AC/DC 0.8 N /0.4 N Must drop-out voltage AC/DC 0. N /0. N echnical data Mechanical life AC/DC cycles /0 0 6 See relays Electrical life at rated load AC cycles Operate/release time ms 7/3 - (/4 sens.) 40.5 Insulation according to EN kv/ Insulation between coil and contacts (./50µs) kv 6 (8mm) 40.6 Dielectric strength between open contacts Ambient temperature range V AC C, Min. impulse duration 0 ms Envirommental protection R I Approvals: (according to type) BEAB GOS RINA C S *** Nominal voltage ( N ): V DC 7

22 .5 =.3 40 Series - Miniature P.C.B. Relays A 40 - Plug-in or P.C.B. versions - Sensitive DC version available - 8 mm, 6 kv (./50 µs) between coil and contacts - Sockets and accessories: see 95 series pole, 0 A mm pinning -P.C.B. mounting - pole, 0 A mm pinning -P.C.B./for use with 95 Series Sockets = * For 400 V applications, where requirements for pollution degree are met. Copper side view Copper side view Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC/sens. DC (50 Hz)/W/W Operating range AC DC/sens. DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Envirommental protection Approvals: (according to type) 8 CO CO 0/0 0/0 50/400* 50/400*,500, /0.3/0. 0/0.3/ (5/5) 300 (5/5) AgCdO AgCdO / /0.5 / /0.5 /( ) N /( ) N /0.4 N /0.4 N /0. N /0. N /0 0 6 / /4 /4 4 kv/3 4 kv/3 6 (8 mm) 6 (8 mm),000, R I R I GOS C S

23 ORDERING INFORMAION 40 Series - Miniature P.C.B. Relays A Example: a 40 series P.C.B. relay with CO contacts, with coil rated at 30 V AC. 4 0 Series ype = P.C.B mm pinning, flat 3 = P.C.B mm pinning 4 = P.C.B mm pinning 5 = P.C.B. - 5 mm pinning 6 = P.C.B. - 5 mm pinning No. of poles = pole for: 40., 0 A 40.3, 0 A 40.4, 0 A 40.5, 0 A 40.6, 6 A = pole for 40.5, 8 A Coil version 6 = AC/DC bistable 7 = Sensitive DC 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications A: Contact material 0 = Standard AgNi for: 40.3/5/5 AgCdO for 40.6 = AgCdO (standard for 40./4) 4 = AgSnO 5 = AgNi + Au (5µm) B: Contact circuit 0 = CO 3 = NO Preferred versions All versions A B C D 0 0 D: Special versions 0 = Standard = Wash tight (R III) 3 = High temperature (+5 C) wash tight C: Options 0 = None Only combinations in the same row are possible coil version A B C D 40./4 sens.dc /5 AC/DC/sens.DC AC/DC/sens.DC AC/DC/sens.DC coil version A B C D 40. sens.dc sens.dc /5 AC/sens.DC /5 DC AC/sens.DC DC AC/sens.DC DC /5/ bistable /6 40 ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 ( CO) ( CO) overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4kV) SRGE (according to EN ) level 3 (kv) OHER DAA BONCE IME: NO/NC ms /5 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/4 ( CO) 3/3 ( CO) POWER LOS O HE ENVIRONMEN without contact current W 0.6 with rated current W. (40./3/4/5) (40.6/5) RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 9

24 CONAC SPECIFICAIONS 40 Series - Miniature P.C.B. Relays A F 40 H CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. - ype 40.5 (8 A) - ypes 40., 40.3, 40.4, 40.5 (0 A) - ype 40.6 (6 A) DC BREAKING CRREN (A) A B DC VOLAGE (V) Breaking capacity for DC load. - ype ypes 40., 40.3, 40.4, ype 40.5 A - Load applied to contact B - Load applied to contacts in series When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. 3 0

25 COIL SPECIFICAIONS 40 Series - Miniature P.C.B. Relays A DC VERSION DAA (0.65 W standard - ypes 40.3/5/5/6) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , , , , DC VERSION DAA (0.5 W standard - ypes 40.3/5/5/6) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min * max ** R I at N V V V Ω ma , , , , , , , , * min = 0.8 N for 40.6 ** max =.5 N for DC VERSION DAA (0.5 W sensitive - ypes 40./4) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , AC VERSION DAA (ypes 40.3/5/5/6) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , , , AC/DC VERSION DAA (bistable - ypes 40.3/5/5/6) Nominal Coil Operating range Resistance Rated coil DC: Release voltage code consumption resistance** N min max R I at N R DC V V V Ω ma Ω ,00 3, , ,500 ** R DC = Resistance in DC, R AC =.3 x R DC, W

26 COIL SPECIFICAIONS 40 Series - Miniature P.C.B. Relays A R 40 DC R 40 sens. DC (types 40.3/5/5/6) 40 N.0.5 N /5/ AMBIEN EMPERARE ( C) /5/ AMBIEN EMPERARE ( C) 80 R 40 AC N.0 R 40 sens. DC (types 40./4) N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Wiring Diagram for 40 Series bistable coil version AC Operation DC Operation R AC ~.3 R DC D = N4007 set D set reset reset V DC R DC V AC R AC On momentary closure of the SE switch the relay is magnetised through the diode and the relay contacts transfer to the set position and remain in this position. On momentary closure of the RESE switch the relay is demagnetised through limiting resistor (R AC ) and the contacts return to the reset position. On momentary closure of the SE switch the relay is magnetised and the relay contacts transfer to the set position and remain in this position. On momentary closure of the RESE switch the relay is demagnetised through limiting resistor (R DC ) and the contacts return to the reset position. Notes: he minimum SE or RESE impulse time is 0 ms. he maximum time can be continuous. In practice, always ensure that the SE and RESE contacts cannot be operated simultaneously.

27 95 Series - Sockets and Accessories for 40 Series Relays Approvals (according to type): GOS C S Relay type / 5/ 6 Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount, retaining clip supplied with socket packaging code SPA Plastic retaining and release clip Metal retaining clip way jumper link for and sockets Identification tag Modules (see table below) Ø Ø = - RAED LES: 0 A - 50 V with a current >0 A, the contact terminal must be connected in parallel ( with, 4 with 4, with ) - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: solid wire stranded wire COM 4 NO NC = COM 4 4 NO NC 3 mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 COIL COIL FOR AND SOCKES: 8-way jumper link RAED LES: 0 A - 50 V Series Module imers (see technical data pages 6/3) BLE Mono-function: 4 V AC/DC; function AI; (.5s 60min) Mono-function: 4 V AC/DC; function DI; (.5s 60min) C 99.0 Approvals (according to type): S GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC (6...4) V DC/AC RC (8...60) V DC/AC RC (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

28 95 Series - Sockets and Accessories for 40 Series Relays Approvals (according to type): Relay type , 40.5, 40.6 Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SPA Metal retaining clip Plastic retaing clip way jumper link for and sockets Modules (see table below) RAED LES: 0 A - 50 V with a current >0 A, the contact terminal must be connected in parallel ( with, 4 with 4, with ) - INSLAION: 6 kv (./50µs) - between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 7 mm - MAX WIRE SIZE: solid wire stranded wire mm x6 / x.5 x4 / x AWG x0 / x4 x / x4 COM NC COM 4 NO 4 4 NO COIL COIL NC FOR AND SOCKES: way jumper link RAED LES: 0 A - 50 V Approvals (according to type): GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal. Green LED is standard. Red LED available on request coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

29 95 Series - Sockets and Accessories for 40 Series Relays Relay type 40.3, , 40.5, 40.6 Colour BLE BLACK BLE BLACK P.C.B. socket retaining clip supplied with socket packaging code SMA Metal retaining clip Plastic retaining clip Ø 5.6 Ø Approvals (according to type): Ø Ø RAED LES: 0 A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C Copper side view PACKAGING CODES How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: S P A A Standard packaging SM Metal retaining clip SP Plastic retaining clip SX No retaining clip 5

30 .3 =.7.3 =.7.3 =.7 4 Series - Low-Profile P.C.B. Relays A - Low-profile, only 5.7 mm high - DC coil versions 0.4 W - 8 mm, 6 kv(./50 µs) between coil and contacts - Ambient temperature +85 C - Sockets and accessories: see 95 and 99 series pole, A - low profile, 3.5 mm pinning - P.C.B. / for use with 95 series sockets - pole, 8 A - low profile, 5 mm pinning - P.C.B. / for use with 95 series sockets - pole, 6 A - low profile, 5 mm pinning - P.C.B. / for use with 95 series sockets () 4 (4) 4 4 () = = = * For 400 V applications, where requirements for pollution degree are met. Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) Copper side view Copper side view Copper side view CO CO CO /5 8/5 6/30 50/400* 50/400* 50/400* 3,000,000 4, /0.3/0. 8/0.3/0. 6/0.3/ (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi /0.4 /0.4 /0.4 ( ) N ( ) N ( ) N /0.4 N /0.4 N /0.4 N /0. N /0. N /0. N / / / /4 5/4 5/4 4 kv/3 4 kv/3 4 kv/3 6 (8mm) 6 (8mm) 6 (8mm),000,000, R II R II R II GOS C S

31 4 Series - Low-Profile P.C.B. Relays A ORDERING INFORMAION Example: a 4 series low-profile P.C.B. relay with CO contacts, with coil rated 4 V DC. A B C D Series ype 3 = P.C.B mm pinning 5 = P.C.B. - 5 mm pinning 6 = P.C.B. - 5 mm pinning No. of poles = pole for 4.3, A 4.6, 6 A = pole for 4.5, 8 A Coil version 9 = DC Coil voltage see coil specifications A: Contact material 0 = Standard AgNi 4 = AgSnO 5 = AgNi + Au B: Contact circuit 0 = CO 3 = NO D: Special versions 0 = Flux proof (R II) = Wash tight (R III) C: Options = None Only combinations in the same row are possible Preferred versions coil version A B C D 4.3/5/ DC All versions coil version A B C D 4.3 DC DC DC ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III OHER DAA BONCE IME: NO/NC ms /5 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/5 POWER LOS O HE ENVIRONMEN without contact current W 0.4 with rated current W.7 (4.3). (4.5).8 (4.6) RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 7

32 CONAC SPECIFICAIONS 4 Series - Low-Profile P.C.B. Relays A 4 F 4 CYCLES LOAD RAED CRREN (A) Contact life vs AC load. - ype 4.5 (8 A) at 360 cycles/h. - ype 4.3 ( A) at 360 cycles/h. - ype 4.6 (6 A) at 360 cycles/h. H 4 DC BREAKING CRREN (A) A Breaking capacity for DC load. - ype ype ype 4.5 A - Load applied to contact B - Load applied to contacts in series B DC VOLAGE (V) 3 When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. COIL SPECIFICAIONS DC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , R 4 DC N AMBIEN EMPERARE ( C) Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 8

33 95 Series - Sockets and Accessories for 4 Series Relays Relay type , 4.6 Colour BLE BLACK BLE BLACK P.C.B. socket retaining clip supplied with socket packaging code SNA Metal retaining clip Plastic retaining clip Ø 5.6 Ø Approvals (according to type): Ø Ø RAED LES: 0 A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C Copper side view PACKAGING CODES How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: S N A A Standard packaging SN Low profile metal retaining clip SL Low profile plastic retaining clip SX No retaining clip 9

34 Series - Low Profile P.C.B. Relays 0 A mm high - Very low coil consumption, only 50 mw - 0 mm, 6 kv (./50 µs) between coil and contacts - Ambient temperature +85 C - Sockets: see ype CO, 0 A - 3. mm pinning - P.C.B. mounting or sockets 95 series - NO, 0 A -5 mm pinning - P.C.B. mounting * For 400 V applications, where requirements for pollution degree are met Copper side view Copper side view Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) 30 CO NO 0/5 0/5 50/400* 50/400*,500, /0.3/0. 0/0.3/ (5/5) 300 (5/5) AgCdO AgCdO /0.5 /0.5 (0.7.5) N (0.7.5) N /0.4 N /0.4 N /0.05 N /0.05 N /0 0 6 / /4 6/ 4 kv/3 4 kv/3 6 (0mm) 6 (0mm),000, R II R II GOS C S

35 43 Series - Low Profile P.C.B. Relays 0 A ORDERING INFORMAION Example: a 43 series low-profile P.C.B. relay with CO contact, with coil rated 4 V DC. A B C D Series ype 4 = P.C.B mm pinning (for CO) P.C.B. - 5 mm pinning (for NO) No. of poles = pole, 0 A Coil version 7 = Sensitive DC Coil voltage see coil specifications A: Contact material = Standard AgCdO 4 = AgSnO 5 = AgNi + Au B: Contact circuit 0 = CO 3 = NO Preferred versions coil version A B C D 43.4 sens. DC All versions D: Special versions 0 = Flux proof (R II) = Wash tight (R III) C: Options 0 = None Only combinations in the same row are possible coil version A B C D 43.4 sens. DC ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III OHER DAA BONCE IME: NO/NC ms 3/6 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/0 POWER LOS O HE ENVIRONMEN without contact current W 0.5 with rated current W.3 RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 3

36 43 Series - Low Profile P.C.B. Relays 0 A 43 CONAC SPECIFICAIONS F 43 CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. H 43 DC BREAKING CRREN (A) Breaking capacity in DC load. DC VOLAGE (V) When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. COIL SPECIFICAIONS DC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , ,00 5. R 43 DC N AMBIEN EMPERARE ( C) Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 3

37 95 Series - Sockets and Accessories for 43 Series Relays 95.3 Relay type 43.4 Colour BLE BLACK P.C.B. socket (only for CO version) retaining clip supplied with socket packaging code SNA Metal retaining clip Approvals (according to type): GOS C S - RAED LES: 0 A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C Copper side view PACKAGING CODES How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: S N A A Standard packaging SN Low profile metal retaining clip SX No retaining clip 33

38 .5 =.4 CERIFICACION DE CONFORMIDAD DE LA FABRICACION.5 =.4 44 Series - Miniature P.C.B. Relays 6-0 A - DC and sensitive DC available - 8 mm, 6 kv (./50 µs) between coil and contacts - Ambient temperature +85 C - Sockets and accessories: see 95, 99 and 86 series pole, 6 A -5 mm pinning - P.C.B./ for use with 95 series sockets - pole, 0 A -5 mm pinning - P.C.B./ for use with 95 series sockets = 7.5 = * For 400 V applications, where requirements for pollution degree are met. Copper side view Copper side view Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC/sens. DC (50 Hz)/W Operating range AC DC/sens. DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) 34 CO CO 6/0 0/0 50/400* 50/400*,500, /0.3/0.3 0/0.3/ (5/5) 300 (5/5) AgNi AgNi /0.65/0.5 /0.65/0.5 (0.73.5) N /(0.73.7) N (0.73.5) N /(0.8.7) N /0.4 N /0.4 N /0. N /0. N /0 0 6 / /5 - (/5 sens) 8/5 - (/5 sens) 4 kv/3 4 kv/3 6 (8mm) 6 (8mm),000, R II R II GOS RINA C S

39 44 Series - Miniature P.C.B. Relays 6-0 A ORDERING INFORMAION Example: a 44 series P.C.B. relay with CO 0 A contacts, coil rated 4 V DC. A B C D Series ype 5 = P.C.B. - 5 mm pinning 6 = P.C.B. - 5 mm pinning No. of poles = pole for 44.5, 6 A 44.6, 0 A Coil version 7 = Sensitive DC 9 = DC Coil voltage see coil specifications A: Contact material 0 = Standard AgNi 4 = AgSnO for 44.6 only B: Contact circuit 0 = CO D: Special versions 0 = Flux proof (R II) C: Options 0 = None Only combinations in the same row are possible Preferred versions coil version A B C D 44.5 DC - sens. DC DC - sens. DC All versions coil version A B C D 44.6 DC - sens. DC ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4kV) SRGE (according to EN ) level 3 (kv) OHER DAA BONCE IME: NO/NC ms 4/4 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 3/3 POWER LOS O HE ENVIRONMEN without contact current W 0.6 with rated current W. (44.5).7 (44.6) RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 35

40 CONAC SPECIFICAIONS 44 Series - Miniature P.C.B. Relays 6-0 A 44 F 44 CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. H 44 DC BREAKING CRREN (A) A B DC VOLAGE (V) Breaking capacity for DC load. - ype ype 44.5 A - Load applied to contact B - Load applied to contacts in series When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. COIL SPECIFICAIONS DC VERSION DAA (0.65 W standard) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , , DC VERSION DAA (0.5 W sensitive) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min * max R I at N V V V Ω ma , , , , , , * min = 0.8 N for 44.6 R 44 DC R 44 sens. DC N.0 N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) Operating range (DC version) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 36 Operating range (sensitive DC version) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature.

41 95 Series - Sockets and Accessories for 44 Series Relays Approvals (according to type): GOS C S Relay type 44.5, 44.6 Colour BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SPA Retaining and release clip Metal retaining clip way jumper link for and sockets Identification tag Modules (see table below) 99.0 imer modules 86.0, RAED LES: 0 A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: solid wire stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x Ø = 8.3 = COM 4 4 NO NC 3 FOR SOCKE: COIL way jumper link RAED LES: 0 A - 50 V Series Module imers (see technical data pages 6/3) BLE Mono-function: 4 V AC/DC; function AI; (.5s 60min) Mono-function: 4 V AC/DC; function DI; (.5s 60min) Approvals (according to type): C S GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

42 95 Series - Sockets and Accessories for 44 Series Relays Approvals (according to type): Relay type 44.5, 44.6 Colour BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SPA Metal retaining clip Plastic retaing clip way jumper link for sockets Modules (see table below) RAED LES: 0 A - 50 V with a current >0 A, the contact terminal must be connected in parallel ( with, 4 with 4, with ) - INSLAION: 6 kv (./50µs) - between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 7 mm - MAX WIRE SIZE: solid wire stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x COM NO COIL NC FOR SOCKE: way jumper link RAED LES: 0 A - 50 V Approvals (according to type): GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal. Green LED is standard. Red LED available on request coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC No - remanence (6 kω/w) (0...40) V AC

43 95 Series - Sockets and Accessories for 44 Series Relays Approvals (according to type): Relay type 44.5, 44.6 Colour BLE BLACK P.C.B. socket retaining clip supplied with socket with packagimg code SMA Retaining clip Plastic retaining clip RAED LES: 0 A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C Ø 5.6 Ø Copper side view PACKAGING CODES How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: S P A A Standard packaging SM Metal retaining clip SP Plastic retaining clip SX No retaining clip 39

44 Series - Miniature P.C.B. Relays 6 A - Miniature P.C.B. Faston 50 connect relay - Sensitive DC coil - 8 mm, 6 kv (./50 µs) between coil and contacts - Ambient temperature +5 C - NO contact or NC contact version NO or NC - Max ambient temperature +5 C - P.C.B. mounting + Faston ( NO) ( NC) * For 400 V applications, where requirements for pollution degree are met. Copper side view 40 Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) NO or NC 6/30 50/400* 4, /0.3/ (0/5) AgCdO /0.36 (0.7.) N /0.4 N /0. N / / 4 kv/3 6 (8mm), R II GOS C S

45 45 Series - Miniature P.C.B. Relays 6 A ORDERING INFORMAION Example: a 45 series for P.C.B. relay + Faston 50, NO contact, coil rated V DC. A B C D Series ype 7 = P.C.B. No. of poles = pole, 6 A Coil version 7 = Sensitive DC Coil voltage see coil specifications A: Contact material 0 = Standard AgCdO B: Contact circuit 3 = NO 4 = NC D: Special versions 0 = Flux proof (R II) C: Options 0 = None Only combinations in the same row are possible All versions coil version A B C D 45.7 sens. DC ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III OHER DAA BONCE IME: NO/NC ms 3/ ( NO version) /3 ( NC version) VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/0 POWER LOS O HE ENVIRONMEN without contact current W 0.4 with rated current W.8 RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 CONAC SPECIFICAIONS F 45 H 45 CYCLES LOAD RAED CRREN (A) DC BREAKING CRREN (A) DC VOLAGE (V) Electrical life AC load (+85 C) Breaking capacity for DC load. When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. 4

46 45 Series - Miniature P.C.B. Relays 6 A 45 COIL SPECIFICAIONS DC VERSION DAA (0.36 W sensitive) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , ,000 6 R 45.7 DC N AMBIEN EMPERARE ( C) 00 0 Operating range vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 4

47 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 55 Series - Miniature General Purpose Relays 7-0 A - P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and 4 CO relays types - Sockets and accessories: see 94, 99 and 86 series - R III (wash tight) version available pole, 0 A - P.C.B. mounting -3 pole, 0 A - P.C.B. mounting -4 pole, 7 A - P.C.B. mounting Copper side view Copper side view Copper side view h = 35.8 mm h = 35.8 mm h = 35.8 mm Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) CO 3 CO 4 CO 0/0 0/0 7/5 50/400 50/400 50/50,500,500, /0.5/0. 0/0.5/0. 7/0.5/ (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi /.5/.5/ (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N 0.8 N /0.5 N 0.8 N /0.5 N 0.8 N /0.5 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /3 9/3 9/3 3.6 kv/ 3.6 kv/.5 kv/ ,000,000, R I R I R I GOS RINA C S 43

48 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 55 Series - Miniature General Purpose Relays 7-0 A - Plug-in versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and 4 CO relays types - Sockets and accessories: see 94, 99 and 86 series pole, 0 A - Plug-in for use with 94 Series sockets - 3 pole, 0 A - Plug-in for use with 94 Series sockets - 4 pole, 7 A - Plug-in for use with 94 Series sockets Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) CO 3 CO 4 CO 0/0 0/0 7/5 50/400 50/400 50/50,500,500, /0.5/0. 0/0.5/0. 7/0.5/ (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi /.5/.5/ (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N 0.8 N /0.5 N 0.8 N /0.5 N 0.8 N /0.5 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /3 9/3 9/3 3.6 kv/ 3.6 kv/.5 kv/ ,000,000, R I R I R I GOS RINA C S

49 55 Series - Miniature General Purpose Relays 7-0 A ORDERING INFORMAION Example: a 55 series plug-in relay, 4 CO contacts, coil rated V DC with a lockable test button and mechanical indicator. A B C D Series ype = P.C.B. 3 = Plug-in No. of poles = pole, 0 A 3 = 3 pole, 0 A 4 = 4 pole, 7 A Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications Only combinations in the same row are possible Preferred versions All versions A: Contact material 0 = Standard AgNi = AgCdO 5 = AgNi + 5µm Au B: Contact circuit 0 = CO coil version A B C D 55.3/34 AC/DC /3/4 AC/DC AC/DC coil version A B C D 55.3/34 AC/DC AC AC / DC DC / AC/DC AC DC /3/4 AC/DC D: Special versions 0 = Standard = Wash tight (R III) for 55., 55.3 and 55.4 only 6 = Rear flange mount C: Options 0 = None = Lockable test button = Mechanical indicator 3 = LED (AC) 4 = Lockable test button + mechanical indicator 5 = Lockable test button + LED (AC) 54 = Lockable test button + LED (AC) + mechanical indicator 6 = Double LED (DC not polarized) 7 = Lockable test button + double LED (DC not polarized) 74 = Lockable test button + double LED (DC not polarized) + mechanical indicator 8 = LED + diode (positive to pin /3, DC standard polarity) 9 = Lockable test button + LED + diode (positive to pin /3, DC standard polarity) 94 = Lockable test button + LED + diode (positive to pin /3, DC standard polarity) + mechanical indicator 55 POSSIBLE OPIONS AC DC - Not polarized DC - Standard polarity Option = Option = Option = Option = 0006 REAR FLANGE MON LOCKABLE ES BON AND MECHANICAL FLAG INDICAOR (0040) he dual-purpose Finder test button can be used in two ways: Case ) he plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case ) he plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 45

50 ACCESSORIES 55 Series - Miniature General Purpose Relays 7-0 A Adaptor with top mount flange (for 55.3/33/34) ECHNICAL DAA 55 INSLAION INSLAION according to EN insulation rated voltage V 400 (-3 pole) 50 (4 pole) rated impulse withstand voltage kv 3.6 (-3 pole).5 (4 pole) pollution degree overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4 kv) SRGE (according to EN ) level 4 (4 kv) OHER DAA BONCE IME: NO/NC ms /4 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 6/6 POWER LOS O HE ENVIRONMEN CO 3 CO 4 CO - without contact current W - with rated current W RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 CONAC SPECIFICAIONS F 55 CYCLES Electrical life vs AC load. = 4 CO relay type (7 A). = - 3 CO relay type (0 A). LOAD RAED CRREN (A) H 55 DC BREAKING CRREN (A) 0 A B C DC VOLAGE (V) Breaking capacity for DC load. = - 3 CO type. = 4 CO type. A = Load applied to contact B = Load applied to contacts in series C = Load applied to 3 contacts in series D = Load applied to 4 contacts in series D 46 When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase.

51 COIL SPECIFICAIONS 55 Series - Miniature General Purpose Relays 7-0 A DC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , ,000 4 AC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , , R 55 DC R 55 AC N.0.5 N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) Operating range (DC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Operating range (AC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 47

52 94 Series - Sockets and Accessories for 55 Series Relays Approvals (according to type): GOS C Relay type , Colour BLE BLACK BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SMA Metal retaining clip Plastic retaining and release clip way jumper link for 94.0, and sockets Identification tag Modules (see table below) 99.0 imer modules 86.0, 86.0 Sheet of marker tags for retaining and release clip RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: solid wire stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 76 Ø Ø COM 76 Ø Ø COM 76 Ø 3. 7 Ø COM NO NO NO 4 4 NC 3 3 NC NC FOR 94.0, AND SOCKES: COIL COIL COIL 6-way jumper link RAED LES: 0 A - 50 V Series Module imers (see technical data pages 6/3) BLE Mono-function: 4 V AC/DC; function AI; (.5s 60min) Mono-function: 4 V AC/DC; function DI; (.5s 60min) C S 99.0 Approvals (according to type): GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC Diode (+, non standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Diode (+, non standard polarity) (6...4) V DC LED + Diode (+, non standard polarity) (8...60) V DC LED + Diode (+, non standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

53 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 94 Series - Sockets and Accessories for 55 Series Relays Approvals (according to type): - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: solid wire C Relay type , Colour BLE BLACK BLE BLACK BLE BLACK Screw terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SMA Retaining clip Modules (see table below) 99.0 GOS S stranded wire mm x.5 / x.5 x.5 / x.5 AWG x4 / x6 x4 / x Ø Ø NO 4 4 NC 4 3 COIL = = 4 Ø 3 Ø NO 3 3 NC COIL Ø Ø NO NC 4 3 COIL Approvals (according to type): GOS COM COM Relay type 55.3 Colour BLE BLACK Screw terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SMA Retaining clip Modules (see table below) 99.0 C S - RAED LES: 0 A - 50 V - MAX WIRE SIZE: - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 solid wire stranded wire - AMBIEN EMPERARE: ( ) C mm x.5 / x.5 x.5 / x.5 - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 9 mm AWG x4 / x6 x4 / x6 FOR 94.7, 94.73, AND 94.8 SOCKES: NC NO COM COIL Ø COM Approvals (according to type): GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal. Green LED is standard. Red LED available on request coil indication and EMC suppression modules (see technical data pag. 79) BLE* Diode** (+, standard polarity) (6...0) V DC Diode (+, non standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Diode (+, non standard polarity) (6...4) V DC LED + Diode (+, non standard polarity) (8...60) V DC LED + Diode (+, non standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

54 94 Series - Sockets and Accessories for 55 Series Relays Approvals (according to type): Relay type , Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SMA Retaining clip Plastic retaining and release clip Identification tag Modules (see table below) RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 7 mm - MAX WIRE SIZE: solid wire stranded wire NO 4 4 NC 4 3 COIL NO NC 4 3 COIL mm x6 / x.5 x4 / x COM COM AWG x0 / x4 x / x Approvals (according to type): Relay type 55.3, Colour BLE BLACK Screwless terminal socket: 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SPA Retaining clip Plastic retaining and release clip Identification tag Modules (see table below) RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: (-5 +70) C - WIRE SRIP LENGH: 7 mm - MAX WIRE SIZE: solid wire stranded wire COM NO NC mm x(0..5) x(0..5) AWG x(4 8) x(4 8) COIL 30 FOR , AND SOCKES: Approvals (according to type): GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal. Green LED is standard. Red LED available on request coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

55 CERIFICACION DE CONFORMIDAD DE LA FABRICACION CERIFICACION DE CONFORMIDAD DE LA FABRICACION CERIFICACION DE CONFORMIDAD DE LA FABRICACION 94 Series - Sockets and Accessories for 55 Series Relays 94.4 Approvals (according to type): Relay type , Colour BLE BLACK BLE BLACK BLE BLACK P.C.B. socket retaining clip supplied with socket packaging code SMA Metal retaining clip GOS C S RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - AMBIEN EMPERARE: ( ) C = 3. = = 6.6 = = 4.4 = Copper side view 94. Approvals (according to type): Relay type , Colour BLE BLACK BLE BLACK BLE BLACK Panel mount solder socket: mm thick panel retaining clip supplied with socket packaging code SMA Metal retaining clip GOS C S RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - AMBIEN EMPERARE: ( ) C Approvals (according to type): GOS - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - AMBIEN EMPERARE: ( ) C Relay type , Colour BLE BLACK BLE BLACK BLE BLACK Panel mount socket: M3 screw mount - solder connections retaining clip supplied with socket packaging code SMA Metal retaining clip C S 34 = = 7.5 Ø

56 94 Series - Sockets and Accessories for 55 Series Relays ACCESSORIES Sheet of marker tags for retaining clip (7 tags): 6xmm PACKAGING CODES How to code and identify retaining clip and packaging options for sockets. 55 Code options according to the last three letters: S M A A Standard packaging SM Metal retaining clip SP Plastic retaining clip SX No retaining clip 5

57 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 56 Series - Miniature Power Relays A - Plug-in version - AC or DC coils - Lockable test button and mechanical flag indicator as standard on CO relay type - Sockets and accessories: see 96, and 99 series pole - Plug-in for use with 96 Series sockets (Faston x0.5mm) - NO (.5 mm gap) - Plug-in for use with 96 Series sockets (Faston x0.5mm) -4 pole - Plug-in for use with 96 Series sockets (Faston x0.5mm) * For 400 V applications, where requirements for pollution degree are met **For 4 CO only Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) CO NO.5 mm 4 CO /0 /0 /0 50/400* 50/400* 50/400* 3,000 3,000 3, /0.5/0. /0.6/0.3 /0.5/ (0/5) 500 (0/5) 500 (0/5) AgNi AgNi AgNi ** /.5/ /.3 (0.8.) N (0.8.) N (0.8.) N (0.85.) N (0.85.) N 0.8 N /0.6 N 0.8 N / 0.8 N /0.6 N 0. N /0. N 0. N / 0. N /0. N / / / /8 8/4 8/8 4 kv/3 4 kv/3 4 kv/ ,000,000, R I R I R I GOS C S 53

58 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 56 Series - Miniature Power Relays A - P.C.B. version - AC or DC coils - Lockable test button and mechanical flag indicator as standard on CO relay type pole - P.C.B. mounting - NO (.5 mm gap) - P.C.B. mounting -4 pole - P.C.B. mounting *For 400 V applications, requirements for pollution degree are met. **For 4 CO only Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) Copper side view Copper side view Copper side view h = 37.7 mm h = 36.3 mm h = 35. mm CO NO.5 mm 4 CO /0 / /0 50/400* 50/400* 50/400* 3,000 3,000 3, /0.5/0. /0.6/0.3 /0.5/ (0/5) 500 (0/5) 500 (0/5) AgNi AgNi AgNi ** /.5/ /.3 (0.8.) N (0.8.) N (0.8.) N (0.85.) N (0.85.) N 0.8 N /0.6 N 0.8 N / 0.8 N /0.6 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /8 8/4 8/8 4 kv/3 4 kv/3 4 kv/ ,000,000, R I R I R I GOS C S

59 56 Series - Miniature Power Relays A ORDERING INFORMAION Example: a 56 series plug-in relay with CO contacts, coil rated V DC with a lockable test button and mechanical indicator. A B C D Series ype 3 = Plug-in 4 = P.C.B. No. of poles = pole, A 4 = 4 pole, A Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications Only combinations in the same row are possible Preferred versions All versions A: Contact material 0 = Standard AgNi = AgCdO 4 = AgSnO B: Contact circuit 0 = CO 3 = NO (.5 mm gap) coil version A B C D 56.3 AC/DC AC/DC AC/DC AC/DC coil version A B C D 56.3 AC AC / AC DC DC / AC/DC AC/DC AC AC/DC D: Special versions 0 = Standard 5 = op flange mount (56.34 only) 6 = Rear flange mount 7 = op 35mm rail mount (56.34 only) 8 = Rear 35mm rail mount (56.34 only) C: Options 0 = None = est button = Mechanical indicator 3 = LED (AC only) 4 = Lockable test button + mechanical indicator 5 = Lockable test button + LED (AC only) 54 = Lockable test button + LED (AC only) + mechanical indicator 6 = Double LED (DC not polarized) 7 = Lockable test button + double LED (DC not polarized) 74 = Lockable test button + double LED (DC not polarized) + mechanical indicator 8 = LED + diode (polarity positive to pin 7, DC) 9 = Lockable test button + LED + diode (polarity positive to pin 7, DC) 94 = Lockable test button + LED + diode + mechanical indicator (polarity positive to pin 7, DC) 56 POSSIBLE OPIONS AC DC - Non polarized DC - Standard polarity Option = Option = Option = Option = 0006 REAR FLANGE MON LOCKABLE ES BON AND MECHANICAL FLAG INDICAOR (0040) he dual-purpose Finder test button can be used in two ways: Case ) he plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case ) he plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 55

60 56 Series - Miniature Power Relays A ACCESSORIES Adaptor with top mount flange (for 56.3.x.xxx.xx00) ECHNICAL DAA INSLAION 56 INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4 kv) SRGE (according to EN ) level 4 (4 kv) OHER DAA BONCE IME: NO/NC ms 3/ (NO version) /3 (CO version) VIBRAION RESISANCE (0 55Hz): NO/NC g/g 8/8 POWER LOS O HE ENVIRONMEN CO / NO 4 CO without contact current W.3 with rated current W RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 56

61 56 Series - Miniature Power Relays A CONAC SPECIFICAIONS F CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. = ypes 56.3/4 = ypes 56.34/44 56 H 56 (CO) H 56 (NO) DC BREAKING CRREN (A) 0 A B C D DC VOLAGE (V) DC BREAKING CRREN (A) A B DC VOLAGE (V) Breaking capacity for DC load. A = Load applied to contact. B = Load applied to contacts in series. C = Load applied to 3 contacts in series. D = Load applied to 4 contacts in series. When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. Breaking capacity for DC load. A = Load applied to contact. B = Load applied to contacts in series. When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. 57

62 56 Series - Miniature Power Relays A COIL SPECIFICAIONS 56 DC VERSION DAA ( CO) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , ,000 4 DC VERSION DAA (4 CO) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , ,000 5 AC VERSION DAA ( CO, NO) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , , AC VERSION DAA (4 CO) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , , R 56 DC ( CO) N.0 R 56 AC ( CO, NO) N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) R 56 DC (4 CO) R 56 AC (4 CO) N.0 N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) 58 Operating range (DC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Operating range (AC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature.

63 96 Series - Sockets and Accessories for 56 Series Relays 96.7 Relay type Colour BLE BLACK BLE BLACK Screw terminal socket: panel or 35 mm rail (EN 500) mount retaining clip 094.7/096.7 supplied with socket packaging code SMA Retaining clip Modules (see table below) Approvals (according to type): C S GOS - RAED LES: A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.8 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: NC 4 3 NO NC NO solid wire stranded wire mm x4 / x4 x4 / x.5 AWG x / x x / x4 6 5 COM COM 8 7 COIL 4 3 COIL FOR 96.7 AND SOCKES: 99.0 Approvals (according to type): GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal. Green LED is standard. Red LED available on request coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC Diode (+, non standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Diode (+, non standard polarity) (6...4) V DC LED + Diode (+, non standard polarity) (8...60) V DC LED + Diode (+, non standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

64 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 96 Series - Sockets and Accessories for 56 Series Relays 96. Approvals (according to type): Relay type Colour BLE BLACK BLE BLACK P.C.B. socket retaining clip supplied with socket packaging code SMA Retaining clip GOS - RAED LES: 5 A - 50 V (0 A max for each contact circuit) - DIELECRIC SRENGH: kv AC - AMBIEN EMPERARE: ( ) C C S Copper side view PACKAGING CODES How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: S M A A Standard packaging SM Metal retaining clip SX No retaining clip 60

65 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 60 Series - General Purpose Relays 0 A pin plug-in - AC or DC coils - Lockable test button with mechanical flag indicator - Bifurcated contact option - Sockets and accessories: see 90, 99 and 86 series pole -8 pin -Plug-In for use with 90 series sockets - bifurcated contacts, for low level switching capability -8 pin -Plug-In for use with 90 series sockets -3 pole - pin - Plug-In for use with 90 series sockets * For 400 V applications, where requirements for pollution degree are met Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) CO CO 3 CO 0/0 6/0 0/0 50/400* 50/400* 50/400*,500,500, /0.4/0.5 6/0.3/0. 0/0.4/ (0/5) 50 (5/5) 500 (0/5) AgNi AgNi bifurcated contacts AgNi /.3./.3./.3 (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N 0.8 N /0.5 N 0.8 N /0.5 N 0.8 N /0.5 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /9 9/9 9/9 4 kv/3 4 kv/3 3.6 kv/ ,000,000, R I R I R I GOS RINA C S 6

66 CERIFICACION DE CONFORMIDAD DE LA FABRICACION Series - General Purpose Relays 0 A pin plug-in - AC or DC coils - Lockable test button with mechanical flag indicator - Bifurcated contact option - Sockets and accessories: see 90, 99 and 86 series bifurcated contacts, for low level switching capability - pin -Plug-In for use with 90 series sockets - pole - Faston 87 (4.8x0.8)mm with flange mount - 3 pole - Faston 87 (4.8x0.8)mm with flange mount A B A B * For 400 V applications, where requirements for pollution degree are met Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) 3 CO 6/0 50/400*, /0.3/0. 50 (5/5) AgNi bifurcated contacts CO 3 CO 0/0 0/0 50/400* 50/400*,500, /0.4/0.5 0/0.4/ (0/5) 500 (0/5) AgNi AgNi /.3 (0.8.) N./.3 (0.8.) N./.3 (0.8.) N (0.8.) N 0.8 N /0.5 N 0. N /0. N / /9 3.6 kv/3 3.6, R I (0.8.) N 0.8 N /0.5 N 0. N /0. N / /9 4 kv/3 3.6, R I (0.8.) N 0.8 N /0.5 N 0. N /0. N / /9 3.6 kv/3 3.6, R I GOS RINA C S

67 60 Series - General Purpose Relays 0 A ORDERING INFORMAION Example: a 60 series plug-in relay, 3 CO (3PD) with coil rated V DC, test button and mechanical indicator. A B C D Series ype = 8/ pin plug-in 6 = Faston 87 (mm 4.8x0.8) with flange mount No. of poles = pole 3 = 3 pole Coil version 4 = Current sensing 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications A: Contact material 0 = Standard = AgCdO 5 = AgNi + 5µm Au B: Contact circuit 0 = CO = Bifurcated contacts 60./3-6A only D: Special versions 0 = Standard C: Options 0 = None = Mechanical indicator 3 = LED (AC) 4 = Lockable test button + mechanical indicator 5 = Lockable test button + LED (AC) 54 = Lockable test button + LED (AC) + mechanical indicator 6 = LED + diode (positive to pin, DC) 7 = Lockable test button + LED + diode (positive to pin ) 74 = Lockable test button + LED + diode (positive to pin ) + mechanical indicator 60 Only combinations in the same row are possible Preferred versions coil version A B C D 60./3 AC/DC /63 AC/DC All versions coil version A B C D 60./3 AC AC / AC AC / DC DC / DC DC / current sensing /63 AC/DC POSSIBLE OPIONS AC DC Option = Option = LOCKABLE ES BON AND MECHANICAL FLAG INDICAOR (0040) he dual-purpose Finder test button can be used in two ways: Case ) he plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case ) he plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 63

68 60 Series - General Purpose Relays 0 A ACCESSORIES Sheet of marker tags for relay types 60. and 60.3 (7 tags): 6xmm ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 ( pole) 3.6 (3 pole) pollution degree 3 overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4kV) SRGE (according to EN ) level 4 (4kV) OHER DAA BONCE IME: NO/NC ms /4 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 5/3 POWER LOS O HE ENVIRONMEN CO 3 CO without contact current W.3.3 with rated current W CONAC SPECIFICAIONS F 60 CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. H 60 DC BREAKING CRREN (A) 0 A B C DC VOLAGE (V) Breaking capacity for DC load. A = Load applied to contact B = Load applied to contacts in series C = Load applied to 3 contacts in series When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. 64

69 60 Series - General Purpose Relays 0 A COIL SPECIFICAIONS DC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , , AC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , ,800 6 R 60 DC N.0 R 60 AC N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) Operating range (DC version) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Operating range (AC version) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. CRREN SENSING VERSION Wiring Diagram L L L S K 60 Series - CRREN SENSING AC Coil code I min (A) I N (A) I max (A) R (Ω) N ypical application with current sensing relays. An open circuit filiment of lamp L is detected by the current sensing relay coil (K) which causes the back-up safety lamp L to be energised, and indication of failure at the control panel via lamp S. Example: navigation light. L = Light L = Safety light S = Control light K = Relay 60 Series - CRREN SENSING DC Coil code I min (A) I N (A) I max (A) R (Ω) Other types of current sensing relays are available on request. 65

70 60 Series - General Purpose Relays 0 A Approvals (according to type): GOS Relay type Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount Metal retaining clip Modules (see table below) 99.0 imer module 86.00, 86.0, way jumper link for 90.0 and sockets Double terminal (for easy start connection). - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - ORQE: 0.6 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: solid wire stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 77,5 3, NO NC NC NO ,5 3, NO NC NO NC NO NC ,6 35,5 0,4 6,9 33,5 6,8 49,7 FOR 90.0 AND SOCKES: COIL COM COIL COM COIL COIL COM COM SAR COM COIL 6-way jumper link RAED LES: 0 A - 50 V Series Module imers (see technical data pages 6/3) Multi-voltage: 40 V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05s 00h) Mono-function: 4 V AC/DC; function AI; (.5s 60min) Mono-function: 4 V AC/DC; function DI; (.5s 60min) C 99.0 Approvals (according to type): GOS S * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC Diode (+, non standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Diode (+, non standard polarity) (6...4) V DC LED + Diode (+, non standard polarity) (8...60) V DC LED + Diode (+, non standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

71 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 90 Series - Sockets and Accessories for 60 Series Relays 90. Approvals (according to type): C S - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: solid wire GOS stranded wire mm x6 / x.5 x6 / x.5 AWG x0 / x4 x0 / x4 Relay type Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SMA Retaining clip Modules (see table below) NO NC NC NO NO NC NO NC NO NC COIL COM COM COIL COILCOM COM COM COIL 90. FOR 90.0 AND 90. SOCKES: 99.0 Approvals (according to type): GOS * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal. Green LED is standard. Red LED available on request coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC Diode (+, non standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Diode (+, non standard polarity) (6...4) V DC LED + Diode (+, non standard polarity) (8...60) V DC LED + Diode (+, non standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Residual current by-pass (6 kω/w) (0...40) V AC

72 CERIFICACION DE CONFORMIDAD DE LA FABRICACION CERIFICACION DE CONFORMIDAD DE LA FABRICACION 90 Series - Sockets and Accessories for 60 Series Relays 90.3 Homologations (suivant les types): Relay type Colour BLE BLE Clamp terminal socket: panel or 35 mm rail (EN 500) mount (retaining clip supplied with socket packaging code SMA Metal retaining clip GOS C S - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 7 mm - MAX WIRE SIZE: fil rigide fil flexible mm x6 / x.5 x6 / x.5 NO NC NC NO NC NO COM NC NC AWG x0 / x4 x0 / x4 b a COIL COM COM COIL 34 b 3 a NO COIL COM COM COIL NO Approvals (according to type): Relay type Colour BLE BLACK BLE BLACK Screw terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SMA Metal retaining clip Ø 8. 6 = 35 GOS C S RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.8 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: 4 NO NC NC NO NC NO com NC 5 NC 4 4. = solid wire stranded wire mm x4 / x.5 x4 / x.5 AWG x / x4 x / x4 7 8 COIL COMCOM COIL NO NO COIL COM COM COIL 90.7 Relay type Colour BLACK BLACK Flange mount solder socket mount with M3 screw Approvals (according to type): GOS C S Ø RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - AMBIEN EMPERARE: ( ) C

73 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 90 Series - Sockets and Accessories for 60 Series Relays Relay type P.C.B. socket BLE BLE (Ø 7.5mm) (Ø 9mm) 90.5 Approvals (according to type): '38" '38" GOS C S RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - AMBIEN EMPERARE: ( ) C PACKAGING CODES 60 How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: 9 0. S M A A Standard packaging SM Metal retaining clip SX No retaining clip 69

74 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 6 Series - Power Relays 6 A - Plug-in or P.C.B. versions - AC or DC coils - 3 mm gap between open contacts on NO option - 8 mm, 6 kv (./50 µs) between coil and contacts (internal distance) - Option with coil to contacts SELV insulations - Sockets and accessories see 9, 99 and 86 series pole - P.C.B. mounting -3 pole - P.C.B. mounting - pole - Faston 87 (4.8x0.5)mm - Plug-in use 9 Series socket A B A B A B 6 *With the AgSnO material the maximum peak current is 50A - 5ms on NO contact A Copper side view B A Copper side view B Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) 70 h = 49. mm h = 49. mm CO 3 CO CO 6/30* 6/30* 6/30 50/400 50/400 50/400 4,000 4,000 4, /0.6/0.4 6/0.6/0.4 6/0.6/0.4,000 (0/0),000 (0/0),000 (0/0) AgCdO AgCdO AgCdO /.3./.3./.3 (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N 0.8 N /0.6 N 0.8 N /0.6 N 0.8 N /0.6 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /0 0/0 0/0 4kV/3 4kV/3 4kV/ ,500,500, R I R I R I GOS RINA C S

75 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 6 Series - Power Relays 6 A - Plug-in or P.C.B. versions - AC or DC coils - 3 mm gap between open contacts on NO option - 8 mm, 6 kv (./50 µs) between coil and contacts (internal distance) - Option with coil to contacts SELV insulations - Sockets and accessories see 9, 99 and 86 series pole - Faston 87 (4.8x0.5)mm - Plug-in use 9 Series socket - pole - Faston 50 (6.3x0.8)mm with flange mount - 3 pole - Faston 50 (6.3x0.8)mm with flange mount A B 35.8 A B A B *With the AgSnO material the maximum peak current is 50A - 5ms on NO contact Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) 3 CO 6/30* 50/400 4, /0.6/0.4,000 (0/0) AgCdO CO 6/30* 50/400 4, /0.6/0.4,000 (0/0) AgCdO 3 CO 6/30* 50/400 4, /0.6/0.4,000 (0/0) AgCdO /.3./.3./.3 (0.8.) N (0.8.) N 0.8 N /0.6 N 0. N /0. N / /0 4 kv/3 6, R I (0.8.) N (0.8.) N 0.8 N /0.6 N 0. N /0. N / /0 4 kv/3 6, R I (0.8.) N (0.8.) N 0.8 N /0.6 N 0. N /0. N / /0 4 kv/3 6, R I GOS RINA C S 7

76 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 6 Series - Power Relays 6 A - Plug-in or P.C.B. versions - AC or DC coils - 3 mm gap between open contacts on NO option - 8 mm, 6 kv (./50 µs) between coil and contacts (internal distance) - Option with coil to contacts SELV insulations - Sockets and accessories see 9, 99 and 86 series NO (3mm contact gap) - P.C.B. mounting -3 NO (3mm contact gap) - P.C.B. mounting - NO (3mm contact gap) - Faston 87 (4.8x0.5)mm - Plug-in use 9 Series socket A B A B A B 6 * Distance between contacts 3mm (EN ) **With the AgSnO material the maximum peak current is 50A - 5ms on NO contact A B Copper side view A B Copper side view Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) 7 h = 5. mm h = 5. mm NO 3 mm* 3 NO 3 mm* NO 3 mm* 6/30** 6/30** 6/30** 50/400 50/400 50/400 4,000 4,000 4, /./0.7 6/./0.7 6/./0.7,000 (0/0),000 (0/0),000 (0/0) AgCdO AgCdO AgCdO /3 3/3 3/3 (0.85.) N (0.85.) N (0.85.) N (0.85.) N (0.85.) N (0.85.) N 0.8 N /0.6 N 0.8 N /0.6 N 0.8 N /0.6 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /4 0/4 0/4 4kV/3 4kV/3 4kV/ ,500,500, R I R I R I GOS RINA C S

77 CERIFICACION DE CONFORMIDAD DE LA FABRICACION 6 Series - Power Relays 6 A - Plug-in or P.C.B. versions - AC or DC coils - 3 mm gap between open contacts on NO option - 8 mm, 6 kv (./50 µs) between coil and contacts (internal distance) - Option with coil to contacts SELV insulations - Sockets and accessories see 9, 99 and 86 series NO (3mm contact gap) - Faston 87 (4.8x0.5)mm - Plug-in use 9 Series socket - NO (3mm contact gap) - Faston 50 (6.3x0.8)mm with flange mount -3 NO (3mm contact gap) - Faston 50 (6.3x0.8)mm with flange mount * Distance between contacts 3mm (EN ) A 38. B A B A B **With the AgSnO material the maximum peak current is 50A - 5ms on NO contact Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC (50 Hz) DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) 3 NO 3 mm* 6/30** 50/400 4, /./0.7,000 (0/0) AgCdO NO 3 mm* 6/30** 50/400 4, /./0.7,000 (0/0) AgCdO 3 NO 3 mm* 6/30** 50/400 4, /./0.7,000 (0/0) AgCdO /3 3/3 3/3 (0.85.) N (0.85.) N 0.8 N /0.6 N 0. N /0. N / /4 4 kv/3 6, R I (0.85.) N (0.85.) N 0.8 N /0.6 N 0. N /0. N / /4 4 kv/3 6, R I (0.85.) N (0.85.) N 0.8 N /0.6 N 0. N /0. N / /4 4 kv/3 6, R I GOS RINA C S 73

78 6 Series - Power Relays 6 A ORDERING INFORMAION Example: a 6 series power relay + FASON 50 rear flange mount (6.3 x 0.8 mm) with NO contacts, coil rated at V DC. A B C D Series ype = P.C.B. 3 = Plug-in 8 = Faston 50 (6.3x0.8 mm) with rear flange mount No. of poles = pole 3 = 3 pole Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications Only combinations in the same row are possible Preferred versions All versions A: Contact material 0 = Standard AgCdO 4 = AgSnO B: Contact circuit 0 = CO 3 = NO ( 3 mm contact gap) 5 = CO version with coil to contacts SELV insulation 6 = NO ( 3 mm contact gap) version with coil to contacts SELV insulation coil version A B C D 6./3 AC-DC /33 AC-DC /83 AC-DC coil version A B C D 6./3 AC-DC /33 AC-DC AC-DC AC AC AC / DC DC DC / 6.8/83 AC-DC AC-DC AC AC DC DC D: Special versions 0 = Standard 5 = op flange mount 6 = Rear flange mount 7 = op 35 mm rail mount 8 = Rear 35 mm rail mount 9 = ype 6.8/83 without rear flange mount C: Options 0 = None = Mechanical indicator 3 = LED (AC) 4 = Lockable test button + mechanical indicator 5 = Lockable test button + LED (AC) 54 = Lockable test button + LED (AC) + mechanical indicator 6 = LED + diode (DC polarity positive to pin A/) 7 = Lockable test button + LED + diode (DC polarity positive to pin A/) 74 = Lockable test button + LED + diode (DC polarity positive to pin A/) + mechanical indicator 74

79 6 Series - Power Relays 6 A POSSIBLE OPIONS AC DC 5.3 A B B A Option = Option = Option = 0005 OP MON FLANGE Option = 0500 and 0600 COIL O CONACS PHYSICAL SEPARAOR FOR SELV APPLICAIONS Option = 0007 OP 35mm RAIL MON LOCKABLE ES BON AND MECHANICAL FLAG INDICAOR (0040) he dual-purpose Finder test button can be used in two ways: Case ) he plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case ) he plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 6 ACCESSORIES Mounting adaptor for types 6.3x and 6.8x (M4) , 4,8 7, M4 47, Flange mounting adaptor for types 6.3x and 6.8x Sheet of marker tags for 6 series relays (7 tags): 6xmm

80 6 Series - Power Relays 6 A ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 400 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4 kv) SRGE (according to EN ) level 4 (4kV) OHER DAA BONCE IME: NO/NC ms 3/6 (CO versions) 3/ (NO versions) VIBRAION RESISANCE (0 55Hz): NO/NC g/g 5/3 POWER LOS O HE ENVIRONMEN CO 3 CO NO 3 NO without contact current W with rated current W RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 6 CONAC SPECIFICAIONS F CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. 76 H 6 (CO) DC BREAKING CRREN (A) A B C VOLAGE DC (V) Breaking capacity for DC load. A = Load applied to contact. B = Load applied to contacts in series. C = Load applied to 3 contacts in series. When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. H 6 (NO) DC BREAKING CRREN (A) A B VOLAGE DC (V) Breaking capacity for DC load. A = Load applied to contact. B = Load applied to contacts in series. C = Load applied to 3 contacts in series. When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. C

81 6 Series - Power Relays 6 A COIL SPECIFICAIONS DC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , , AC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , ,800 6 DC (NO) VERSION DAA ( 3 mm) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , ,600.5 AC (NO) VERSION DAA ( 3 mm) Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , ,

82 9 Series - Sockets and Accessories for 6 Series Relays R 6 DC R 6 AC N.0 N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) R 6 DC (NO) R 6 AC (NO) 6 N.0.5 N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) Operating range (DC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Operating range (AC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 78

83 9 Series - Sockets and Accessories for 6 Series Relays 9.03 Approvals (according to type): Relay type 6.3, 6.33 Colour BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip 09.7 supplied with socket packaging code SMA Metal retaining clip 09.7 Modules (see table below) 99.0 imer modules 86.00, 86.0, 86.0 GOS C S - RAED LES: 6 A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.8 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: solid wire stranded wire mm x0 / x4 x6 / x AWG x8 / x x0 / x COM NO NC B A COIL 9.03 FOR 9.03 SOCKE: Series Module imers (see technical data pages 6/3) Multi-voltage: 40 V AC/DC; Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05s 00h) Mono-function: 4 V AC/DC; function AI; (.5s 60min) Mono-function: 4 V AC/DC; function DI; (.5s 60min) C 99.0 Approvals (according to type): GOS S * Modules in Black housing are available on request. **For DC supply, apply the positive to terminal coil indication and EMC suppression modules (see technical data page 79) BLE* Diode** (+, standard polarity) (6...0) V DC Diode (+, non standard polarity) (6...0) V DC LED (6...4) V DC/AC LED (8...60) V DC/AC LED (0...40) V DC/AC LED + Diode** (+, standard polarity) (6...4) V DC LED + Diode** (+, standard polarity) (8...60) V DC LED + Diode** (+, standard polarity) (0...0) V DC LED + Diode (+, non standard polarity) (6...4) V DC LED + Diode (+, non standard polarity) (8...60) V DC LED + Diode (+, non standard polarity) (0...0) V DC LED + Varistor (6...4) V DC/AC LED + Varistor (8...60) V DC/AC LED + Varistor (0...40) V DC/AC RC circuit (6...4) V DC/AC RC circuit (8...60) V DC/AC RC circuit (0...40) V DC/AC Retaining current by-pass (6 kω/w) (0...40) V AC

84 9 Series - Sockets and Accessories for 6 Series Relays 9.3 Relay type 6.3, 6.33 Colour BLE BLACK P.C.B. socket retaining clip supplied with socket packaging code SMA Metal retaining clip Approvals (according to type): GOS C S - RAED LES: 6 A - 50 V (0 A max for each contact circuit) - DIELECRIC SRENGH:.5 kv AC - AMBIEN EMPERARE: ( ) C - 6.3X plug on 9.3 is 63.3 mm high 40 =.. = Approvals (according to type): RAED LES: 6 A - 50 V (0 A max for each contact circuit) - DIELECRIC SRENGH:.5 kv AC - AMBIEN EMPERARE: ( ) C = = Relay type 6.3, 6.33 Colour BLE Panel mount solder socket: mounted with M3 screw 9.33 retaining clip supplied with socket packaging code SMA Metal retaining clip GOS C S PACKAGING CODES How to code and identify retaining clip and packaging options for sockets. Code options according to the last three letters: S M A A Standard packaging SM Metal retaining clip SX No retaining clip 80

85 65 Series - Power Relays 0-30 A - P.C.B. or Flange mount - AC or DC coils NO + NC - Flange mount - Faston 50 (6.3 x 0.8 mm) - NO + NC - P.C.B. mounting - Bifurcated terminals 4 4 a b a b a 4 b * For 400 V applications, where requirements for pollution degree are met Copper side view h = 46 mm Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) NO + NC NO + NC 0/40 0/40 50/400* 50/400* 5,000 5,000,000, /0.8/0.5 0/0.8/0.5,000 (0/0),000 (0/0) AgCdO AgCdO /.3./.3 (0.8.) N (0.8.) N (0.85.) N (0.85.) N 0.8 N /0.6 N 0.8 N /0.6 N 0. N /0. N 0. N /0. N / / / 0/ 4 kv/3 4 kv/3 4 4,500, R I R I GOS C S 8

86 65 Series - Power Relays 0-30 A P.C.B. or Flange mount - AC or DC coils - 3 mm gap between open contacts on NO version NO (3mm contact gap) - Flange mount - Faston 50 (6.3 x 0.8 mm) - NO (3mm contact gap) - P.C.B. mounting - Bifurcated terminals 4 4 a b a b * For 400 V applications, where requirements for pollution degree are met a 4 b ** Distance between contacts >3mm (EN ) Copper side view h = 4 mm 8 Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Environmental protection Approvals: (according to type) NO 3 mm** NO 3 mm** 30/50 30/50 50/400* 50/400* 7,500 7,500,50, /./0.7 30/./0.7,000 (0/0),000 (0/0) AgCdO AgCdO /.3./.3 (0.8.) N (0.8.) N (0.85.) N (0.85.) N 0.8 N /0.6 N 0.8 N /0.6 N 0. N /0. N 0. N /0. N / / /4 5/4 4 kv/3 4 kv/3 4 4,500, R I R I GOS C S

87 65 Series - Power Relays 0-30 A ORDERING INFORMAION Example: a 65 series power relay, for P.C.B. with bifurcated terminals, NC + NO contact with a V DC coil. 6 5 A B C D Series ype 3 = Faston 50 (6.3x0.8 mm) with rear flange mount 6 = P.C.B. with bifurcated terminals No. of poles = NC + NO A: Contact material 0 = Standard AgCdO B: Contact circuit 0 = NO + NC 3 = NO ( 3 mm contact gap) D: Special versions 0 = Standard 5 = op flange mount 7 = op 35 mm rail (EN 500) mount 8 = Rear 35 mm rail (EN 500) mount C: Options 0 = None Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications Only combinations in the same row are possible Preferred versions coil version A B C D 65.3 AC-DC AC-DC All versions coil version A B C D 65.3 AC-DC AC-DC POSSIBLE OPIONS Option = 0005 OP FLANGE MON Option = 0008 REAR 35 mm RAIL MON ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4kV) SRGE (according to EN ) level 4 (4kV) OHER DAA BONCE IME: NO/NC ms 5/6 ( NO + NC version) 7/ (NO version) VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/4 POWER LOS O HE ENVIRONMEN NO + NC NO -without contact current W.3.3 -with rated current W. 3. RECOMMENDED DISANCE between RELAYS mounted on P.C.B.s mm 5 83

88 65 Series - Power Relays 0-30 A CONAC SPECIFICAIONS F 65 CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. H 65 DC BREAKING CRREN (A) A B Breaking capacity for DC load. Load applied to contact A - NO + NC type B - NO type DC VOLAGE (V) 0 65 When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. COIL SPECIFICAIONS DC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N V V V Ω ma , , , , , AC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code consumption N min max R I at N (50Hz) V V V Ω ma , , , , ,800 6 R 65 DC N.0 R 65 AC N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) Operating range (DC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 84 Operating range (AC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature.

89 9 Series - Modular Auto-Off-On Relay 0 A - 3 functions selector switch: Auto (works as a monostable relay) Off (relay permanently OFF) On (relay permanently ON) - LED indicator - 35 mm rail (EN 500) mount - Insulation between supply and contact terminals 9. -One module (. mm) wide - pole - feedback contact. B B A3 4 Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Supply specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range V AC V DC echnical data Mechanical life cycles Electrical life at rated load in AC cycles Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals: (according to type) CO 0/5 50/400, /0.3/0.,000 (0/0) AgCdO /0.4 (0.8.) N (0.8.) N , IP 0 GOS 85

90 ORDERING INFORMAION 9 Series - Modular Auto-Off-On Relay 0 A Example: a 9 series relay modular Auto-Off-On with CO - 0 A contact, rated at 4 V AC/DC supply Series ype = 35 mm rail (EN 500) mount,. mm No. of poles = pole Supply voltage 04 = 4 V Supply version 0 = AC (50/60 Hz)/DC ECHNICAL DAA CONAC SPECIFICAIONS NOMINAL RAE LAMPS - incandescent (30V) W,000 - compensated fluorescent (30V) W uncompensated fluorescent (30V) W 500 INSLAION - halogen (30V) W,000 DIELECRIC SRENGH - between supply and contacts V AC 3, between open contacts V AC,000 OHER DAA POWER LOS O HE ENVIRONMEN - without contact current W with rated current W.8 MAX WIRE SIZE solid cable stranded cable mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x6 SCREW ORQE Nm 0.5 WIRING DIAGRAM SELECOR POSIION L (+) N ( ) 4 V AC/DC Selector switch Control Output relay LED B B contact switch (S) S A3 AO Closed ON ON Closed Open OFF OFF Closed ON ON ON Open B B ON OFF AO PROECION AND INDICAION CIRCI 4 OFF OFF OFF Open he B - B contact signals when the selector switch is in the Auto position. he LED indicates the state of the Modular relay s output contacts. ype 9. he max switching voltage between B and B terminal is 4 V AC/DC (300mA). ACCESSORIES Sheet of marker tags (40 tags): 8x0mm

91 38 Series - Relay Interface Modules A - Relay interface modules for use with PLC systems, 6. mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil indication and protection circuit - Instant removal of relay using plastic retaining clip - 35 mm rail (EN 500) mounting / Screw terminal - Electromechanical relay - 35 mm rail mounting - Screwless terminal - Electromechanical relay - 35 mm rail mounting - Leakage current suppression - Electromechanical relay - 35 mm rail mounting V~ protection and indication circuit 4 protection and indication circuit 4 leakage current suppression circuit 4 * for 400 V applications, requirements for pollution degree are met. 38 Contact specifications Contact configuration Rated current/maximum peak current A CO CO CO 6/0 6/0 6/0 Rated voltage/maximum switching voltage V AC 50/400* 50/400* 50/400* Rated load in AC Rated load in AC5 (30 C),500,500, Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications 6/0./0.5 6/0./0.5 6/0./ (/0) 500 (/0) 500 (/0) AgNi AgNi AgNi Nominal voltage ( N ) Rated power AC/DC Operating range Holding voltage Must drop-out voltage echnical data V DC/AC V DC (50 Hz)/W AC/DC DC AC/DC AC/DC AC see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 see table page N /0.6 N 0.6 N /0.6 N 0.6 N /0.6 N 0. N /0.05 N 0. N /0.05 N see table page 9 Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range ( 60V/>60V) C Protection category Approvals (relay): (according to type) /0 0 6 /0 0 6 / /6 5/6 5/6 4 kv/3 4 kv/3 4 kv/3 6 (8mm) 6 (8mm) 6 (8mm),000,000, / / / IP0 IP0 IP0 GOS 87

92 38 Series - Relay Interface Modules A - Relay interface modules for use with PLC systems, 6. mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil indication and protection circuit - Instant removal of relay using plastic retaining clip - 35 mm rail (EN 500) mounting / Screw terminal - SSR relay - 35 mm rail mounting - Screwless terminal - SSR relay - 35 mm rail mounting - Leakage current suppression - SSR relay - 35 mm rail mounting protection and indication circuit 4 (3+ protection and indication circuit 4 (3+ leakage current suppression circuit 4 (3+) 0-40 V~ 38 Output circuit Rated current/maximum peak current (0 ms) A /0 0./0.5 /0 0./0.5 /0 0./0.5 Rated voltage/maximum blocking voltage Switching voltage range Minimum switching current V DC V DC ma 4/33 48/60 4/33 48/60 4/33 48/ Max OFF-state leakage current µa Max ON-state voltage drop Input circuit Nominal voltage Operating range Control current Release voltage Impedance echnical data V V V DC ma V DC Ω DC 4-60 DC AC/DC AC see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 see table page 9 3,00,300 3,00,300 Operate/release time µs Dielectric strength between input/output V Ambient temperature range C Environmental protection Approvals: (according to type) 00/400 0/0 00/400 0/0 00/400 0/0,500,500, IP0 IP0 IP0 88

93 38 Series - Relay Interface Modules A ORDERING INFORMAION ELECROMECHANICAL RELAY (EMR) Example: a 38 series relay interface module with CO contact, with coil rated at V DC. A B C D Series ype 5 = Electromechanical relay, with screw terminal 6 = Electromechanical relay, with screwless terminal No. of poles = pole, 6 A Coil version 0 = AC (50/60 Hz)/ DC 3 = Leakage current suppression (for 0 5C/DC C only) 7 = Sensitive DC Coil voltage see coil specifications D: Special versions 0 = Standard C: Options 5 = Standard DC 6 = Standard AC/DC B: Contact circuit 0 = CO A: Contact material 0 = AgNi Standard 4 = AgSnO 5 = AgNi + Au SOLID SAE RELAY (SSR) Example: a 38 series SSR relay interface module with A, with 4 V DC supply Series ype 8 = SSR relay, with screw terminal 9 = SSR relay, with screwless terminal Output = NO Supply version 3 = Leakage current suppression 7 = DC Supply voltage see input specifications Output circuit 904 = A - 4 V DC 7048 = 0.A - 48 V DC he 38 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at 0..5C and C. his problem can occur, for example, when connecting the interface modules to PLC s with triac outputs or when connecting via relatively long cables. 89

94 ELECROMECHANICAL RELAY ECHNICAL DAA 38 Series - Relay Interface Modules A INSLAION INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4kV) SRGE (according to EN ) level 3 (kv) OHER DAA BONCE IME: NO/NC ms /6 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/5 POWER LOS O HE ENVIRONMEN W 0. (V) (40V) without contact current W 0.5 (V) -.5 (40V) WIRE SRIP LENGH with rated current mm SCREW ORQE Nm 0.5 MAX WIRE SIZE solid cable stranded cable solid cable stranded cable 38 mm x.5 / x.5 x.5 / x.5 x.5 x.5 AWG x4 / x6 x4 / x6 x4 x4 CONAC SPECIFICAIONS F 38 CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. H 38 DC BREAKING CRREN (A) Breaking capacity in DC load. DC VOLAGE (V) When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. 90

95 COIL SPECIFICAIONS 38 Series - Relay Interface Modules A AC/DC VERSION DAA Nominal Coil Operating range Rated coil Power voltage code consumption consumption N min max I at N P at N V V V ma W (*) 0.6(*) (*) 0.9(*) (*) Rated coil consumption and power consumption values relate to N = 5 and 40 V. DC VERSION DAA (sensitive) Nominal Coil Operating range Rated coil Power voltage code consumption consumption N min max I at N P at N V V V ma W YPE / DAA Nominal Coil Operating range Must Rated coil Power voltage code drop out consumption consumption N min max I at N P at N V V V ma W 0 5 AC/DC (*) (*) AC (*) 0.5(*) (*) Rated coil consumption and power consumption values relate to N = 5 and 40 V. 38 R 38 N AMBIEN EMPERARE ( C) 80 Operating range Vs ambient temperature. - Max coil voltage permitted at nominal load ( 60 V versions). - Max coil voltage permitted at nominal load (>60 V versions). 3 - Min pick-up voltage with coil at ambient temperature. 9

96 SOLID SAE RELAY 38 Series - Relay Interface Modules A OHER DAA POWER LOS O HE ENVIRONMEN without contact current W 0.7 with rated current W 0.4 WIRE SRIP LENGH mm SCREW ORQE Nm 0.5 MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x.5 / x.5 x.5 / x.5 x.5 x.5 AWG x4 / x6 x4 / x6 x4 x4 INP SPECIFICAION DC VERSION DAA Nominal Supply Operating range Release Control voltage code voltage current N min max I at N V V V V ma YPE / DAA Nominal Supply Operating range Release Rated coil Power voltage code voltage consumption consumption N min max I at N P at N V V V ma W 0 5 AC/DC (*) (*) AC (*) 0.5(*) (*) Rated coil consumption and power consumption values relate to N = 5 and 40 V. 38 OP SPECIFICAION L 38/A L 38/0.A 3.5 SWICHING CRREN AMBIEN EMPERARE ( C) SWICHING CRREN AMBIEN EMPERARE ( C) ype 38.8/9 (A-4VDC) Switching current vs ambient temperature ype 38.8/9 (00mA-48VDC) Switching current vs ambient temperature 9

97 38 Series - Relay Interface Modules A COMBINAIONS Approvals (according to type): GOS C S COMBINAION FOR ELECROMECHANICAL RELAY Code Supply voltage ype of relay ype of socket V AC/DC V AC/DC V AC/DC V AC/DC V AC/DC V AC/DC V AC/DC V AC V DC V DC V DC V DC V DC V AC/DC V AC/DC V AC/DC V AC/DC V AC/DC V AC V DC V DC COMBINAION FOR SSR RELAY Code Supply voltage ype of relay ype of socket xxxx 4 V DC xxxx xxxx 60 V DC xxxx xxxx V AC/DC xxxx xxxx V AC xxxx xxxx 4 V DC xxxx xxxx 60 V DC xxxx xxxx V AC/DC xxxx xxxx V AC xxxx ACCESSORIES 0-way jumper link for 38 series Approvals (according to type): - RAED LES: 36 A - 50 V C S Plastic separator hickness mm, required at the start and the end of a group of interfaces. Can be used for visual separation group, must be used for: - protective separation of different voltages of neighbouring PLC interfaces according to VDE protection of cut jumper links Sheet of marker tags (64 tags): 6x0mm

98 48 Series - Relay Interface Modules A - Relay interface modules for use with PLC systems, 5.8 mm wide - AC or sensitive DC coil versions available - Instant removal of relay using plastic retaining clip - Supply status indication or coil suppression module provided - Identification label - 35 mm rail (EN 500) mounting pole, 0 A - 35 mm rail mounting - pole, 8 A - 35 mm rail mounting - pole, 6 A - 35 mm rail mounting COM COM COM COM COM COM NO 4 NO 4 4 NO 4 4 NO 4 4 NO 4 4 NO NC NC NC NC NC NC /6 + AC DC AC + DC + AC DC * For 400 V applications, where requirements for pollution degree are met Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/sens. DC (50 Hz)/W Operating range AC sens. DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals (relay): (according to type) CO CO CO 0/0 8/5 6/30 50/400* 50/50 50/400*,500,000 4, /0.3/0. 8/0.3/0. 6/0.3/ (5/5) 300 (5/5) 500 (0/5) AgNi AgNi AgCdO /0.5./0.5./0.5 (0.8.) N (0.8.) N (0.8.) N ( ) N ( ) N (0.8.5) N 0.8 N /0.4 N 0.8 N /0.4 N 0.8 N /0.4 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /4 (AC) - / (DC) 7/4 (AC) - / (DC) 7/4 (AC) - / (DC) 4 kv/3 4 kv/ 4 kv/3 6 (8mm) 6 (8mm) 6 (8mm),000,000, IP 0 IP 0 IP 0 BEAB GOS RINA C S

99 48 Series - Relay Interface Modules A - Relay interface modules for use with PLC systems, 5.8 mm wide - AC or sensitive DC coil versions available - Instant removal of relay using plastic retaining clip - Supply status indication or coil suppression module provided - Identification label - 35 mm rail (EN 500) mounting pole, 0 A - 35 mm rail mounting COM NO NC DC * For 400 V applications, where requirements for pollution degree are met. Contact specification 48 Contact configuration CO Rated current/maximum peak current A 0/0 Rated voltage/maximum switching voltage V AC 50/400* Rated load in AC,500 Rated load in AC5 (30 C) 500 Single phase motor rating (30 C) kw 0.37 Breaking capacity in DC: 30/0/0V A 0/0.3/0. Minimum switching load mw (V/mA) 300 (5/5) Standard contact material AgNi Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/sens. DC (50 Hz)/W /0.5 Operating range AC sens. DC (0.8.5) N Holding voltage AC/DC /0.4 N Must drop-out voltage AC/DC /0. N echnical data Mechanical life AC/DC cycles /0 0 6 Electrical life at rated load AC cycles Operate/release time ms / (DC) Insulation according to EN kv/3 Insulation between coil and contacts (./50µs) kv 6 (8mm) Dielectric strength between open contacts V AC,000 Ambient temperature range C Protection category IP 0 Approvals (relay): (according to type) C S GOS RINA 95

100 48 Series - Relay Interface Modules A ORDERING INFORMAION Example: a 48 series, 35 mm rail (EN 500) mount relay interface module, with CO - 6 A, coil rated 4 V sensitive DC, green LED + diode. A B C D Series ype 3 = 35 mm rail mount 5 = 35 mm rail mount 6 = 35 mm rail mount No. of poles = pole for 48.3, 0 A 48.6, 6 A = pole for 48.5, 8 A 48.6, 0 A, DC only Coil version 7 = Sensitive DC 8 = AC (50/60 Hz) Coil voltage see coil specifications A: Contact material 0 = Standard B: Contact circuit 0 = CO D: Special versions 0 = Standard C: Options 5 = Standard for DC: green LED + diode (polarity +) 6 = Standard for AC: green LED + Varistor ECHNICAL DAA INSLAION 48 INSLAION according to EN insulation rated voltage V 50 rated impulse withstand voltage kv 4 pollution degree 3 (48.3/6/6) (48.5) overvoltage category III IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4kV) SRGE (according to EN ) level 3 (kv) OHER DAA BONCE IME: NO/NC ms /5 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 0/4 ( CO) 3/3 ( CO) POWER LOS O HE ENVIRONMEN without contact current W 0.7 with rated current W. (48.3).3 (48.5). (48.6). (48.6) WIRE SRIP LENGH mm 8 SCREW ORQE Nm 0.5 MAX WIRE SIZE solid cable stranded cable mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 96

101 CONAC SPECIFICAIONS 48 Series - Relay Interface Modules A F 48/ 0 7 F 48/ 0 7 CYCLES 0 6 CYCLES LOAD RAED CRREN (A) Electrical life vs AC load. - ype 48.5 (8 A). - ype 48.3 (0 A). ype 48.6 (6 A) Electrical life vs AC load. ype 48.6 (0 A). LOAD RAED CRREN (A) H 48/ DC BREAKING CRREN (A) A Breaking capacity for DC load. - ype ype ype A - Load applied to contact B - Load applied to contacts in series B DC VOLAGE (V) When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. 3 H 48/ DC BREAKING CRREN (A) A Breaking capacity for DC load. - ype A - Load applied to contact B - Load applied to contacts in series B DC VOLAGE (V) When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase

102 COIL SPECIFICAIONS 48 Series - Relay Interface Modules A DC VERSION DAA (0.5 W sensitive) Nominal Coil Operating range Rated coil voltage code consumption N min * max I at N V V V ma * min = 0.8 N for 48.6 and 48.6 R 48 sens. DC AC VERSION DAA Nominal Coil Operating range Rated coil voltage code consumption N min max I at N (50Hz) V V V ma R 48 AC N /5/6 N /5 48.6/ AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) 48 Operating range (sensitive DC version) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Operating range (AC version) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. COMBINAIONS Code ype of Socket ype of Relay Module Retaining Clip ACCESSORIES 8-way jumper link for 48 series RAED LES: 0 A - 50 V PACKAGING CODES How to code and identify retaining clip and packaging options for relay interface module. Code options according to the last three letters: S P A A Standard packaging B Blister packaging SP Plastic retaining clip 98

103 58 Series - Relay Interface Modules 7-0 A - Relay interface modules for use with PLC systems, 7mm wide - AC and DC versions available - Supply status indication and coil suppression module provided - Identification label - 35 mm rail (EN 500) mounting pole, 0 A - 35 mm rail mounting - 3 pole, 0 A - 35 mm rail mounting -4 pole, 7 A - 35 mm rail mounting COM NO COM NO COM NO 4 4 NC 3 3 NC NC COIL Example: AC Example: DC Example: AC COIL 4 3 COIL Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw (V/mA) Standard contact material Coil specifications Nominal voltage ( N ) V AC (50/60 Hz) V DC Rated power AC/DC (50 Hz)/W Operating range AC DC Holding voltage AC/DC Must drop-out voltage AC/DC echnical data Mechanical life AC/DC cycles Electrical life at rated load AC cycles Operate/release time ms Insulation according to EN Insulation between coil and contacts (./50µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals (relay): (according to type) CO 3 CO 4 CO 0/0 0/0 7/5 50/400 50/400 50/50,500,500, /0.5/0. 0/0.5/0. 7/0.5/ (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi /.5/.5/ (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N (0.8.) N 0.8 N /0.5 N 0.8 N /0.5 N 0.8 N /0.5 N 0. N /0. N 0. N /0. N 0. N /0. N / / / /3 (AC) - 9/5 (DC) 9/3 (AC) - 9/5 (DC) 9/3 (AC) - 9/5 (DC) 3.6 kv/ 3.6 kv/.5 kv/ ,000,000, IP 0 IP 0 IP 0 GOS RINA C S 58 99

104 58 Series - Relay Interface Modules 7-0 A ORDERING INFORMAION Example: a 58 series 35 mm rail (EN 550) mounting interface module, 4 CO, 4 V DC coil with green LED + diode. A B C D Series ype 3 = 35mm rail mount No. of poles = pole, 0 A 3 = 3 pole, 0 A 4 = 4 pole, 7 A Coil version 8 = AC (50/60 Hz) 9 = DC Coil voltage see coil specifications A: Contact material 0 = AgNi Standard B: Contact circuit 0 = CO D: Special versions 0 = Standard C: Options 5 = Standard DC: green LED + diode (polarity +) 6 = Standard AC: green LED + varistor ECHNICAL DAA INSLAION INSLAION according to EN insulation rated voltage V 400 (-3pole) 50 (4 pole) rated impulse withstand voltage kv 3.6 (, 3 pole).5 (4 pole) pollution degree overvoltage category III 58 IMMNIY CONDCED DISRBANCE IMMNIY BRS (according to EN ) level 4 (4kV) SRGE (according to EN ) level 4 (4kV) OHER DAA BONCE IME: NO/NC ms /4 VIBRAION RESISANCE (0 55Hz): NO/NC g/g 6/6 POWER LOS O HE ENVIRONMEN without contact current W with rated current W 3 (58.3, 58.34) 4 (58.33) WIRE SRIP LENGH mm 8 SCREW ORQE Nm 0.5 MAX WIRE SIZE solid cable stranded cable mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 00

105 58 Series - Relay Interface Modules 7-0 A CONAC SPECIFICAIONS F 58 H 58 CYCLES Electrical life vs AC load. = 4 CO relay type (7 A). = - 3 CO relay type (0 A). LOAD RAED CRREN (A) DC BREAKING CRREN (A) 0 A B C Breaking capacity for DC load. = - 3 CO type. = 4 CO type. A = Load applied to contact B = Load applied to contacts in series C = Load applied to 3 contacts in series D = Load applied to 4 contacts in series D DC VOLAGE (V) When switching a resistive load (DC) having voltage and current values under the curve the expected electrical life is cycles. In case of DC3 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC load. Note: the release time of load will be increase. COIL SPECIFICAIONS DC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code absorption N min max R I at N V V V Ω ma ,400 0 AC VERSION DAA Nominal Coil Operating range Resistance Rated coil voltage code absorption N min max R I at N (50Hz) V V V Ω ma , , , R 58 DC R 58 AC N.0.5 N AMBIEN EMPERARE ( C) AMBIEN EMPERARE ( C) Operating range (DC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. Operating range (AC type) vs ambient temperature. - Max coil voltage permitted. - Min pick-up voltage with coil at ambient temperature. 0

106 58 Series - Relay Interface Modules 7-0 A COMBINAIONS Code ype of Socket ype of Relay Module Retaining Clip ACCESSORIES 6-way jumper link for 58 series RAED LES: 0 A - 50 V Sheet of marker tags (7 tags): 6xmm PACKAGING CODES How to code and identify retaining clip and packaging options for relay interface module. 58 Code options according to the last three letters: S P A A Standard packaging B Blister packaging SP Plastic retaining clip 0

107 7 Series - Monitoring Relay 0 A - Designed for industrial applications - Positive safety logic - make contact opens if the measured value is outside of the acceptable range - High precision - measured value based on the average of 500 measurements over a 00ms period - Industry standard module - 35 mm rail (EN 500) mounting - Switch or link setting of the delay time - LED status indication phase 30 V -- line voltage monitoring - Detects over and under voltage against fixed limits - Long switch-on delay, avoiding problems associated with high inrush currents phase 30 V -- line voltage monitoring - Detects over and under voltage against adjustable limits - Long switch-on delay, avoiding problems associated with high inrush currents Line voltage detection 30 V AC 50/60 Hz - Detection levels (0.75.) N, fixed - Delay time 5 min or 0 min link selectable - Line voltage detection 30 V AC 50/60 Hz - Detection levels (± 5 ± 0) %, N adjustable - Delay time 5 min or 0 min switch selectable L N = 30 V AC 50/60 Hz L N = 30 V AC 50/60 Hz Z Z : (0.75.) N Fixed limits % ~ > < 0 min min ~ > < 0 min 5 min Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 V) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw/(v/ma) Standard contact material Supply specification Nominal voltage V AC(50/60) Hz V DC Rated power AC/DC 50 Hz/ W Operating range AC DC echnical data Electrical life at rated load AC cycles Detection levels Switch-on delay time/reaction time s Fault memory Electrical isolation: Supply to Measuring circuits Insulation according to EN Ambient temperature range C Protection category Approvals: (according to type) CO CO 0/5 0/5 50/400 50/400,500, /0.3/0. 0/0.3/ (5/5) 300 (5/5) AgCdO AgCdO / 4/ (0.75.) N ( ) N (0.75.) N (±5 ±0) % N (5-0) min/< 0.5 (0. )/< 0.5 None circuits are electrically common None circuits are electrically common 6 kv 6 kv IP0 IP0 7 03

108 7 Series - Monitoring Relay 0 A - Designed for industrial applications - Positive safety logic - make contact opens if the measured value is outside of the acceptable range - High precision - measured value based on the - average of 500 measurements over a 00ms period - Industry standard module - 35 mm rail (EN 500) mounting - Adjustable setting of the detecting levels - LED status indication phase 400 V - line voltage monitoring - Detects over and under voltage against adjustable limits - Long switch-on delay, avoiding problems associated with high inrush currents - Line voltage detection 400 V AC 50/60 Hz - Detecting levels' (± 5 ± 0) % N, adjustable - Delay time 5 min or 0 min switch selectable L L L3 A = 400 V AC 3~ 50/60 Hz % phase 400 V - line voltage monitoring - Detects over and under voltage against adjustable limits - Adjustable switch-on delay -Switch selectable fault memory - Line voltage detection 400 V AC 50/60 Hz - Detecting level ( ) N > >.5 N - Delay time -- (0. ) s adjustable - Fault memory, switch selectable - Fault acknowledgement by switch manipulation from ON to OFF and back to ON, or power down L L L3 A = 400 V AC 3~ 50/60 Hz % Contact specification 7 Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 V) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw/(v/ma) Standard contact material Supply specification Nominal voltage V AC(50/60) Hz V DC Rated power AC/DC 50 Hz/ W Operating range AC DC echnical data Electrical life at rated load AC cycles Detection level Switch-on delay/switch-off delay/reaction time s Fault memory - selectable Electrical isolation: Supply to Measuring circuits Insulation according to EN Ambient temperature range C Protection category Approvals: (according to type) 3~ > < min 5 min 3~ > < CO CO 0/5 0/5 50/400 50/400,500, /0.3/0. 0/0.3/ (5/5) 300 (5/5) AgCdO AgCdO / 4/ (0.8.) N (0.8.5) N (±5 %...±0 %) N ( ) % N... (.5) N fixed 0, s s Memory ON (5-0) min / < 0.5 (0.... ) s / < 0.5 Yes None circuits are electrically common None circuits are electrically common 6 kv 6 kv IP0 IP0 OFF 04

109 7 Series - Monitoring Relay 0 A - Designed for industrial applications - Positive safety logic - make contact opens if the measured value is outside of the acceptable range - High precision - measured value based on the average of 500 measurements over a 00ms period - Industry standard module - 35 mm rail (EN 500) mounting - Adjustable setting of the detecting levels - LED status indication phase asymmetry monitoring - Phase rotation monitoring - Phase loss monitoring - Line voltage detection 400 V AC 50/60 Hz - Asymmetry of one or two phases (-5-0) % N adjustable - Detection of the supply voltage to () and/or (5) >. N L L L3 = 400 V AC 3~ 50/60 Hz A ~ ASY Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 V) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw/(v/ma) Standard contact material Supply specification Nominal voltage V AC(50/60) Hz V DC Rated power AC/DC 50 Hz/ W Operating range AC DC echnical data Electrical life at rated load AC Detection level: Phase asymmetry: Adjustable Switch-off delay /activation time s Fault memory Electrical isolation: Supply to Measuring circuits Insulation according to EN Ambient temperature range C Protection category Approvals: (according to type) CO 0/5 50/400, /0.3/ (5/5) AgCdO 400 4/ ( ) N (-5-0) % N / < 0.5 None circuits are electrically common 6 kv IP0 7 05

110 7 Series - Monitoring Relay 0 A - niversal voltage or current detecting and monitoring relay - Programmable for: - DC or AC detection level - range detecting: upper and lower value upper set point minus hysteresis range ( )% for switch on - lower set point plus hysteresis range ( )% for switch on - Fault memory - Electrical isolation between measuring and supply circuits - Immune to supply interruptions of < 00 ms - Wide detecting range Voltage: DC ( ) V, AC ( ) V Programmable universal voltage detecting module - AC/DC voltage detection - adjustable - AC 50/60 Hz (5 480) V - DC ( ) V - Switch-on hysteresis (5 50) % - Switch-off delay (0. ) s L N ~ + ~ Z Z = 30 V AC 50/60 Hz programmable AC: ( ) V DC: ( ) V Programmable universal current detecting module, - sable with current transformer 50/5, 00/5, 50/5, 50/5, 300/5, 400/5 or 600/5 - AC/DC current detection - adjustable - AC 50/60Hz (0...0)A with current transformer to 600A - DC (0...0)A - Switch-on hysteresis -- ( ) % - Switch-off delay (0. ) s - Switch-on delay (0. 0) s L N ~ + I ~ Z Z = 30 V AC 50/60 Hz programmable I AC: (0,...0) A 600 A DC: (0,...0) A 85, 45 ~ > < 0, s s ~I > < I 0, s 0, s s 0 s Memory Memory 7 06 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 V) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw/(v/ma) Standard contact material Supply specification Nominal voltage V AC(50/60) Hz V DC Rated power AC/DC 50 Hz/ W Operating range AC DC echnical data Electrical life at rated load AC cycles Detection levels AC 50/60 Hz/DC Switch-off/ reaction/ switch on reaction time s Switch-on level of the detecting level % Fault memory - programmable Electrical isolation: Supply to Measuring circuits Insulation according to EN Ambient temperature range C Protection category Approvals: (according to type) CO CO 0/5 0/5 50/400 50/400,500, /0.3/0. 0/0.3/ (5/5) 300 (5/5) AgCdO AgCdO / 4 / ( ) N ( ) N ( ) V/( ) V (0. 0) A at transducer to 600A / (0. 0) A (0. ) / < 0.35 / < 0.5 (0. ) / < 0.35 / (0. 0) Yes Yes Yes Yes 6 kv 6 kv IP0 IP0

111 7 Series - Monitoring Relay 0 A - Designed for industrial applications - Positive safety logic - make contact opens if the measured value is outside of the acceptable range - Industry standard module - 35 mm rail (EN 500) mounting - Adjustable setting of the detecting levels - LED status indication hermistor relay - hermistor relay with fault memory 78.8 IN+ IN 35 -emperature detection with PC - PC short circuit detecting - PC wire breakage detecting - Supply voltage 30 V AC 50/60 Hz - emperature detection with PC - Fault memory switch selectable - Reset by activity of the Reset button or supply interruption - PC short circuit detecting - PC wire breakage detecting - Supply voltage 30 V AC 50/60 Hz L N = 30 V AC 50/60 Hz L N = 30 V AC 50/60 Hz Z Z ϑ ϑ PC ype A DIN VDE 0660 Part 303 Z ϑ Z Reset B B ϑ PC ype A DIN VDE 0660 Part 303 ϑ > < ϑ > < Memory ON OFF 4 4 Reset Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 V) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw/(v/ma) Standard contact material Supply specification Nominal voltage V AC(50/60) Hz V DC Rated power AC/DC 50 Hz/ W Operating range AC DC echnical data Electrical life at rated load AC cycles PC detecting: Short circuit/emperature OK Reset/PC break Delay time/activation time s Fault memory switch selectable Electrical isolation: Supply to Measuring circuits Insulation according to EN Ambient temperature range C Protection category Approvals: (according to type) NO NO + NC 0/5 0/5 50/400 50/400,500, /0.3/0. 0/0.3/ (5/5) 300 (5/5) AgCdO AgCdO / / ( ) N ( ) N <0 Ω / >0 Ω... <3 kω <0 Ω / >0 Ω... <3 kω <.3 kω / >3 kω <.3 kω / >3 kω / < 0.5 / < 0.5 Yes Yes Yes 6 kv 6 kv IP0 IP0 7 07

112 7 Series - Monitoring Relay 0 A ORDERING INFORMAION niversal measuring relay with LCD display for AC/DC voltage detecting, with one CO contact for 0 A 50 V-AC and 30 V supply voltage, programmable delay time and fault memory Series ype = phase AC line monitoring 3 = 3 phase AC line monitoring 4 = AC/DC universal- Voltage detection 5 = AC/DC universal- Current detection 9 = hermistor relay (temperature monitoring with PC thermistor) No. of poles = CO at 7., 3, = NO at 7.9 = NO and NC at 7.9 Supply version 8 = AC (50/60 Hz) Supply voltage 30 = 30 V 400 = 400 V Additional functions 0 = basic function = adjustable detection value = adjustable: Asymmetry, phase loss, phase rotation Special versions 0 = no fault memory = fault memory Options 0 = no delay time = two fixed delay times = adjustable delay times Contact circuit 0 = CO 3 = NO 4 = NO + NC Mounting width / 35 mm / 35 mm / 35 mm / 35 mm / 35 mm / 35 mm / 35 mm /.5 mm /.5 mm 08

113 7 Series - Monitoring Relay 0 A ECHNICAL DAA EMC SPECIFICAIONS ELECROSAIC DISCHARGE - contact discharge EN kv - air discharge EN kv RADIO-FREQENCY ELECROMAGNEIC FIELD (80,000) MHz EN V/m FAS RANSIENS (burst) (5-50 ns, 5 khz) on (,, A3, R, R) and ( Z, Z) EN kv SRGES (./50 µs) on (,, A3, R, R) and (Z, Z) - common mode EN kv - differential mode EN kv RADIO-FREQENCY COMMON MODE ( MHz) to - EN V RADIAED AND CONDCED EMISSION EN 550 class B INSLAION INSLAION according to EN Insulation rated voltage V 50 Rated impulse withstand voltage kv 4 Pollution degree 3 Over-voltage category III DIELECRIC SRENGH (,, A3, R, R), and V (AC),500 CONAC ERMINALS (,, 4) and ERMINALS (Z, Z) kv (,/50 µs) 6 DIELECRIC SRENGH A OPEN CONAC V (AC),000 OHER DAA Voltage and current values at terminals Z Z ype 7. Link for time range V / ma 30 V / ype 7.9, 7.9 PC temperature measurement V / ma 4 V /,4 Maximum length of wiring to the Supply terminals / ype 7., 7.3 Contact bridge for time range m 50 / Measuring terminals. ype 7.4 Voltage measurement m 50 / 50 ype 7.5 Current measurement m 50 / 50 (Wiring capacitance no greater than 0 nf/00m) ype 7.9, 7.9 PC temperature measurement m 50 / 50 Measuring principle ype 7., 7.3, 7.4, 7.5, he measured value is the arithmetical average of 500 individual 7.9, 7.9 measurements taken over a 00ms period. interruptions less than 00 ms are ignored. Safety logic ype 7., 7.3, 7.4, 7.5, Positive safety logic - When the value being monitored lie in the 7.9, 7.9 acceptable area, the make contact is closed. Reaction time (following the application of the supply ype 7., 7.3, 7.4, 7.5, 0,5 s voltage 7.9, 7.9 Power lost to the environment - without contact load 4 - with rated current 5 Permitted storage temperature range C Protection category IP 0 Max. wire size solid cable standed cable mm 0.5 ( x,5) ( x,5) AWG 0 ( x 4) ( x 6) Screw torque Nm

114 7 Series - Monitoring Relay 0 A FNCIONS - Overview ypes imes Supply Module Contact voltage width conf. Monitoring Relay - ype -phase 30V, nder/over voltage. 3-phase 400V, nder/over voltage. 3-phase 400V, Phase symmetry. 3-phase 400V, Phase loss. 3-phase 400V, Phase. DC voltage ( ) V nder and Over voltage monitoring. AC voltage ( ) V nder and Over voltage monitoring. DC current (0,...0) A nder and Over current monitoring. AC current (0,...0) A(or to 600 A with current transformers) nder and Over current monitoring. hermistor relay (PC) + Memory. Adjustable. Fault memory for 7.4 and 7.5 Delay time 5 / 0 min. Delay time (0, ) s adjustable. Power-up activation time delay (0,... 0) s starting inrush current suppression. 30 V AC. 400 V AC. 35 mm wide..5 mm wide. Relay contact, 50 V AC / 0 A CO CO CO CO CO CO CO NO NO NC 7 Current transformer Source as required 0

115 7 Series - Monitoring Relay 0 A Explanation of relay marking and LED/LCD display Monitoring relay without LCD-display ON LED green steady light: Supply voltage is on and measuring system is active. DEF Default: he detected value is outside of the acceptable range. (Asymmetric is shown by the LED ASY) LED red flashing: Delay time is running. See the function diagram. LED red steady light: Output relay is off. Contact -4 (6-) is open. ASY Phase asymmetry is outside of the predefined range. LED steady light: Output relay is turned off. Contact -4 (6-) is open. LEVEL Selected range as % value. IME Delay time (min = minutes) or (s = seconds). MEMORY Fault memory switched on: he state of the output relay after the occurrence of a fault (contact -4 (6-) open) will be ON maintained, monitored value returns to within acceptable limits. Fault reset is made by switch manipulation from ON to OFF to ON, or by power down ( ), or by operating of the "RESE" button ( ). MEMORY Fault memory turned off: he state of the output contacts will only remain in the fault condition (contact -4 (6-) OFF open) while the monitored value is outside of the acceptable limits. When the monitored value returns within the acceptable limits the contact will revert to the energised state. Monitored equipment will start again automatically. Monitoring relay with LCD-display SE/RESE Relay 7.4 and 7.5. Sets and resets the programmable values - see operating instructions in the packing SELEC Relay 7.4 and 7.5. Selects the desired parameter for programming - see operating instructions DEF Default, LED red steady or flashing. PROG Modus Enter the programming mode by simultaneously pressing the buttons "SE/RESE" and "SELEC" for 3 secs. he word "prog" is shown for sec. "SELEC" allows the choice of "AC" or "DC", and is confirmed with "SE/RESE". Successively pressing the button "SELEC" brings up the choices of p, Lo, or plo. he appropriate choice is made by pressing the "SE/RESE" button. he next steps will program the appropriate values and the selection of the fault memory function (which is selected with a "YES" or "NO"). If all programming steps are completed the display will read "end". Short programming After repeatedly pressing the "SE/RESE" button the measured value will be displayed, or "0" appears if nothing is connected instruction to Z and Z (5 and 9). If the programming is broken off before end is shown in the display the previous program will remain unchanged after an interruption of the supply voltage. Program query Pushing the "SELEC" button for at least sec, enters the "program inquiry mode". he programmed mode and the values are shown on the repeated pressing of the "SELEC" button. Flashing M (Memory) Fault memory has had effect (fault acknowledgement and reset is made by a 3 second press of the "SESE/RESE button ") LCD-display V = volt Level = value t = - time during which short-time A = amp Hys = hysteresis fluctuations are not taken into account p = upper limit (with hysteresis in down direction) M = Memory (fault) t = - (monitoring relay 7.5) the time Lo = lower limit (with hysteresis in up direction) Yes = yes - with memory during which inrush currents are not taken plo = upper and lower limit - range detecting no = no - without memory into account. 7

116 LED/LCD status announcement/advice ype Starting mode Normal operation Abormal mode Reset Memory OFF ON OFF After connecting = 5 or 0 min -4 open Normal operation Set point is OK -4 is closed Normal operation Set point is OK -4 is closed 7 Series - Monitoring Relay 0 A ime runs Set point is immaterial -4 is open Will close after, if set point is OK ime runs Set point is not OK -4 is closed After expiry of Set point is not OK -4 is open Will close, if set point is OK After expiry of Set point is not OK -4 is open Will close, if set point is OK Memory ON ON Normal operation Set point is OK -4 is closed ime runs Set point is not OK -4 is closed After expiry of Set point is not OK -4 is open Will not close at RESE After expiry of Set point is OK -4 is open Will close at RESE OFF Normal operation Set point is OK -4 is closed Supply voltage to () and / or (5) is missing -4 is open Will close if supply voltage restored and set point OK Incorrect phase rotation or phase failure or voltage () and/or (5) is >. N -4 is open Will close, if set point is OK Phase asymmetry -4 is open Will close, if set point is OK Memory OFF Measured value displayed Normal operation Set point is OK -4 is closed Measured value displayed ime runs Set point is not OK -4 is closed Measured value displayed After expiry of Set point is not OK -4 is open Will close, if set point is OK Memory ON Measured value displayed Normal operation Set point is OK -4 is closed Measured value displayed ime runs Set point is not OK -4 is closed M in the display flashes Measured value displayed After expiry of Set point is not OK -4 is open Will not close at RESE M in the display - static Measured value displayed After expiry of Set point is OK -4 is open Will close at RESE Memory OFF Measured value displayed ime runs Set point immaterial -4 is closed Measured value displayed Normal operation Set point is OK -4 is closed Measured value displayed ime runs Set point is not OK -4 is closed Measured value displayed After expiry of Set point is not OK -4 is open Will close if set point OK Memory ON Measured value displayed ime runs Set point immaterial -4 is closed Measured value displayed Normal operation Set point is OK -4 is closed Measured value displayed ime runs Set point is not OK -4 is closed M in the display flashes Measured value displayed After expiry of Set point is not OK -4 is open Will not close at RESE M in the display - static Measured value displayed After expiry of Set point is OK -4 is open Will close at RESE Normal operation Set point is OK -4 is closed emperature too high or PC line break or PC short circuit -4 is open Will close if set point OK Memory OFF ON OFF Normal operation Set point is OK -4 is closed emperature too high or PC line break or PC short circuit -4 is open Will close if set point OK Memory ON ON Normal operation Set point is OK -4 is closed emperature too high or PC line break or PC short circuit -4 is open emperature is OK -4 is open Will close at RESE OFF

117 7 Series - Monitoring Relay 0 A FNCIONS L N ype Z Z ~ > < = 30 V AC 50/60 Hz : (0.75.) N Fixed limits 0 min min, N N 0,75 N 0,0 N DEF Switch off: Immediately if monitored value is outside of the set points. Switch on: After expiry of the time and if monitored value is within the set points C-4 C = output contact NO -4 (6-) closed L N L L L3 L L L3 ype ~ > < A = 30 V AC 50/60 Hz ype ~ > < % 0 min 5 min = 400 V AC 3~ 50/60 Hz % ype A ~ > < min 5 min = 400 V AC 3~ 50/60 Hz % 0, s s Memory ON OFF N + x% N N x% 0,0 N DEF C-4 N + x% N N x% 0,0 N DEF C-4 N N x%+% N x% MEMORY OFF MEMORY ON,5 N,4 N 0,0 N DEF C DEF C t< * t< t< *RESE MEMORY = By power-down or switch manipulation from ON to OFF to ON * Switch off: Immediately if monitored value is outside of the set points. Switch on: After expiry of the time and if monitored value is within the set points. C = output contact NO -4 (6-) closed, all values within the set points Switch off: Immediately if monitored value is outside of the set points. Switch on: After expiry of the time and if monitored value is within the set points. C = output contact NO -4 (6-) closed Switch off: If monitored value is outside of the set points and time has elapsed. Switch on: MEMORY OFF: Immediately monitored value returns within limits (off-set by % hysteresis) Switch on: MEMORY ON: As above, but subject to the RESE operation having been actioned. RESE: By Memory switch manipulation from ON to OFF and back to ON, or power down 7 C = output contact NO -4 (6-) closed 3

118 7 Series - Monitoring Relay 0 A FNCIONS L L L3 ype A ~ ASY = 400 V AC 3~ 50/60 Hz,N N 0,8N 0,N N 0,8N 0,N N 0,8N 0 ASY DEF ON L L L L3 L L3 L3 L L3-5 -0% Switch off: Phase asymmetry Incorrect phase rotation Phase loss LED ASY yellow Phase asymmetry LED DEF red Voltage to () and/or (5) >. N Incorrect phase rotation Phase loss to A3 (9) LED ON green Monitoring system is active and 400 V supply voltage is connected to -5 or -- C-4 C = output contact NO -4 (6-) closed 7 L N ype Z Z ~ > < ~ + ~ = 30 V AC 50/60 Hz Programmable AC: ( ) V DC: ( ) V 0, s s Memory p Lo p p Hys Lo +Hys MEMORY ON MEMORY OFF Lo 0,0 N DEF C -4 DEF C -4 t t t * * * * t t t Lo...Lo + Hys p...p Hys p...lo RESE MEMORY = Pressing "SE/RESE" > sec Switch off: Lo mode If the monitored value is less than the lowerlimit and, time has expired p mode If the monitored value is higher than the upper limit, and time has expired Lo p - mode If the monitored value of voltage is outside of the upper or lower voltage limits, and time has expired Voltage dips < do not result in output relay switching off Switch on: Lo or p - modes When passing the hysteresis value Lo p mode - When passing the Lo or p value RESE MEMORY: Pressing "SE/RESE" > sec C = output contact NO -4 (6-) closed 4

119 7 Series - Monitoring Relay 0 A FNCIONS L N ype ~ + I ~ Z Z = 30 V AC 50/60 Hz Programmable I AC: (0,...0) A 600 A DC: (0,...0) A I p I Lo I p I p Hys I Lo +Hys Switch off: I Lo - mode If the monitored value is less than the lowerlimit and, time has expired ~I > < I 0, s 0, s s 0 s Memory MEMORY ON MEMORY OFF I Lo 0,0 N DEF C -4 DEF C -4 t t t * * * t t t ILo...ILo + Hys Ip...Ip Hys Ip...ILo I p mode If the monitored value is higher than the upper limit, and time has expired I Lo I p - mode If the monitored value of current is outside of the upper or lower limits, and time has expired Inrush current < is ignored *RESE MEMORY = pressing SE/RESE > sec Current dips < do not result in output relay switching off Switch on: I Lo or I p mode When passing the hysteresis value I Lo I p mode When passing the ILo or Iup values 7 RESE MEMORY: Pushing "SE/RESE" > sec C = output contact NO -4 (6-) closed L N ype ϑ Z Z = 30 V AC 50/60 Hz ϑ PC ype A DIN VDE 0660 R [Ω] Switch off: - hermistor line break - Over temperature RPC >(,5 3,6)kΩ, - hermistor line short circuit (R PC <0Ω) - Loss of supply ϑ > < DEF C-4 *PC-Break **PC-Short circuit * ** Switch on: emperature within limits RPC >(,0,5)kΩ on power-up. (kω.5kω) on cooling C = output contact NO (-4) Closed when emperature within limits 5

120 7 Series - Monitoring Relay 0 A FNCIONS L N Z ype ϑ > < Z 4 ϑ Reset B B = 30 V AC 50/60 Hz ϑ PC ype A DIN VDE 0660 Memory ON OFF Reset MEMORY ON MEMORY OFF R [Ω] DEF C -4 C - DEF *** C -4 C - *PC-Break **PC-Short circuit * ** ***RESE MEMORY = Operate the RESE key, or interrupt the supply Switch off: - hermistor line break - Over temperature RPC >(.5 3.6)kΩ - hermistor line short circuit RPC <0Ω - Loss of supply Switch on: emperature within limits (0Ω.5kΩ) on power-up. RPC >(.0.5)kΩ on cooling. Select MEMORY OFF: If monitored value is expected to cross the resetting threshold. Select MEMORY ON: If monitored value is expected to remain within limits. RESE MEMORY: Operate the RESE key, or interrupt the supply. 7 C = output contacts NO (-4) Closed when emperature within limits NC (-) Closed when emperature outside limits / Power off 6

121 80 Series - Modular imers 6 A - Mono-function and multi-function versions available - Rotary selector mm wide - Six time scales from 0.s to 0h - 35 mm rail (EN 500) mount - High input/output insulation B - Multi-voltage - Multi-function - Mono-voltage -Mono-function - Mono-voltage -Mono-function AI: ON delay DI: ON pulse SW: Symmetrical recycler: ON start BE: Signal OFF delay CE: Signal ON and OFF delay DE: Signal ON pulse AI: ON delay DI: ON pulse N/- L/+ N/- L/+ N/- L/+ N/- L/+ S B Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) wiring diagram (without signal SAR) wiring diagram (with signal SAR) wiring diagram (without signal SAR) wiring diagram (without signal SAR) CO CO CO 6/30 6/30 6/30 50/400 50/400 50/400 4,000 4,000 4, /0.3/0. 6/0.3/0. 6/0.3/ (0/5) 500 (0/5) 500 (0/5) AgCdO AgCdO AgCdO (non polarized) 4 (non polarized) <.8/ <.4 <.8/ < 0.6 <.8/ < V ( ) N ( ) N V ( ) N ( ) N (0. ) s, ( 0) s, (0. ) min, ( 0) min, (0. ) h, ( 0) h ± ± ± ±5 ±5 ± IP 0 IP 0 IP 0 GOS 80 7

122 80 Series - Modular imers 6 A - Mono-function and multi-function versions available - Rotary selector mm wide - Six time scales from 0.s to 0h - 35 mm rail (EN 500) mount - High input/output insulation B - Mono-voltage -Mono-function - Multi-voltage -Mono-function BE: Signal OFF delay LI: Asymmetrical recycler (ON starting) LE: Signal asymmetrical recycler (ON starting) N/- L/+ N/- L/+ N/- L/+ B S S B B B Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) wiring diagram (with signal SAR) wiring diagram (without signal SAR) CO CO 6/30 6/30 50/400 50/400 4,000 4, /0.3/0. 6/0.3/ (0/5) 500 (0/5) AgCdO AgCdO <.8/ < 0.6 <.8/ <.4 ( ) N V ( ) N V wiring diagram (with signal SAR) (0. ) s, ( 0) s, (0. ) min, ( 0) min, (0. ) h, ( 0) h ± ± ±5 ± IP 0 IP 0 GOS

123 80 Series - Modular imers 6 A ORDERING INFORMAION Example: a 80 series, modular timers, CO, 6 A, supply rated at 40 V AC/DC Series ype 0 = Multi-function (AI, DI, SW, BE, CE, DE) = ON delay (AI) = ON pulse (DI) 4 = Signal OFF delay (BE) 9 = Asymmetrical recycler ON starting (LI, LE) Supply voltage 04 = 4 V AC/DC 40 = V AC (80., 80., 80.4) 40 = V AC/DC (80.0, 80.9) Supply version 0 = AC (50/60 Hz)/DC (80.0, 80.9) 8 = AC (50/60 Hz) (80., 80., 80.4) No. of poles = CO ACCESSORIES Sheet of marker tags (4 tags) for types 80.0///4: 9x7mm ECHNICAL DAA EMC SPECIFICAIONS YPE OF ES REFERENCE SANDARD ELECROSAIC DISCHARGE - contact discharge EN kv - air discharge EN kv RADIO-FREQENCY ELECROMAGNEIC FIELD ( MHz) EN V/m FAS RANSIENS (burst) (5-50 ns, 5 khz) on Supply terminals EN kv SRGES (./50 µs) on Supply terminals - common mode EN kv - differential mode EN kv on start terminal (B) - common mode EN kv - differential mode EN kv RADIO-FREQENCY COMMON MODE ( MHz) on Supply terminals EN V RADIAED AND CONDCED EMISSION EN 550 class B 80 INSLAION DIELECRIC SRENGH - between input and output circuit V AC 4,000 - between open contacts V AC,000 INSLAION (./50 µs) between input and output kv 6 OHER DAA CRREN ABSORPION on signal control (B) < ma POWER LOS O HE ENVIRONMEN - without contact current W.3 - with rated current W 3. MAX WIRE SIZE solid cable stranded cable mm x6 / x4 x4 / x.5 AWG x0 / x x / x4 SCREW ORQE Nm 0.8 9

124 80 Series - Modular imers 6 A FNCIONS LED Supply voltage NO output contact Contacts Open Closed = Supply voltage S = Signal switch = Output contact OFF ON ON Open Open Open (iming in Progress) ON Closed Without signal Start = Start via contact in supply line (). With signal Start = Start via contact into control terminal (B). Wiring diagram Without signal SAR N/- L/+ ype t< (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed t< (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset t< (SW) Symmetrical recycler: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ratio is : (time on = time off). 80 With signal SAR N/- L/+ S B S S t< (BE) Signal OFF delay. Power is permenently applied to the timer. he output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. (CE) Signal ON and OFF delay. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset S t< (DE) Signal ON pulse. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. Without signal SAR N/- L/ B N/- L/ With signal SAR 80.9 S ON OFF ON OFF t<on ON OFF ON OFF t<on NOE: time scales and functions must be set before energising the timer. (LI) Asymmetrical recycler (ON starting). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ON and OFF times are independently adjustable. (LE) Signal asymmetrical recycler (ON starting) Power is permenently applied to the timer. Closing Signal Switch (S) causes the output contacts to transfer immediately and cycle between ON and OFF, until opened. S B N/ L/+ * S B * - With DC supply, positive polarity has to be connected to B terminal (according to EN 6004-). - A voltage other than the supply voltage can be applied to the command Start (B), example: - = 30 V AC B - = V DC

125 85 Series - Miniature Plug-in imers 7-0 A - Plug-in timer relay -, 3 or 4 CO contact available - Seven time scales, from 0.05s to 00h - Multifunctions - Sockets: see 94 series Pole, 0A - AC/DC supply non polarized - Plug-in for use with 94 series sockets -3 Pole, 0A - AC/DC supply non polarized - Plug-in for use with 94 series sockets -4 Pole, 7A - AC/DC supply non polarized - Plug-in for use with 94 series sockets AI: ON delay DI: ON pulse SW: Symmetrical recycler: ON start GI: Fixed pulse (0.5s) delayed AI: ON delay DI: ON pulse SW: Symmetrical recycler: ON start GI: Fixed pulse (0.5s) delayed AI: ON delay DI: ON pulse SW: Symmetrical recycler: ON start GI: Fixed pulse (0.5s) delayed N/ (+) L/+( ) N/ (+) L/+( ) N/ (+) L/+( ) wiring diagram wiring diagram wiring diagram Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V AC/DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) CO 3 CO 4 CO 0/0 0/0 7/5 50/400 50/400 50/50,500,500, /0.5/0. 0/0.5/0. 7/0.5/ (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi (non polarized) / / / (0.85.) N (0.85.) N (0.85.) N (0.85.) N (0.85.) N (0.85.) N (0.05 ) s, (0.5 0) s, (5 00) s, (0.5 0) min, (5 00) min, (0.5 0) h, (5 00) h ± ± ± ±5 ±5 ± IP 40 IP 40 IP 40 GOS C S 85

126 ORDERING INFORMAION 85 Series - Miniature Plug-in imers 7-0 A Example: 85 series timer, 4 CO, 4 V AC/DC supply voltage with AI - DI functions Series ype 0 = Multifunction (AI, DI, GI, SW) No. of poles = pole - 0 A 3 = 3 pole - 0 A 4 = 4 pole - 7 A Supply voltage 0 = V AC/DC 04 = 4 V AC/DC 048 = 48 V AC/DC 5 = 0 5 V AC/DC 40 = V AC Supply version 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) for 40 V only ECHNICAL DAA EMC SPECIFICAIONS YPE OF ES REFERENCE SANDARD ELECROSAIC DISCHARGE - contact discharge EN n.a. - air discharge EN kv RADIO-FREQENCY ELECROMAGNEIC FIELD ( MHz) EN V/m FAS RANSIENS (burst) (5-50 ns, 5 khz) on Supply terminals EN kv SRGES (./50 µs) on Supply terminals - common mode EN kv - differential mode EN kv RADIO-FREQENCY COMMON MODE ( MHz) on Supply terminals EN V POWER-FREQENCY (50 Hz) EN A/m RADIAED AND CONDCED EMISSION EN 550 class B OHER DAA POWER LOS O HE ENVIRONMEN pole 3 pole 4 pole - without contact current W with rated current W IME SCALES ( ) s ( ) s (5...00) s ( ) min (5...00) min ( ) h (5...00) h NOE: time scales and functions must be set before energising the timer.

127 85 Series - Miniature Plug-in imers 7-0 A FNCIONS LED Supply voltage NO output contact Contacts Open Closed = Supply voltage OFF Open x - x4 x - x = Output contact ON ON Open Open (iming in Progress) x - x4 x - x4 x - x x - x ON Closed x - x x - x4 Wiring diagram ypes: 85.0, 85.03, N/ (+) L/+( ) 34 5 t< (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed t< (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. N/ (+) L/+( ) s (GI) Fixed pulse (0.5s) delayed. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5s. 0.5s t< (SW) Symmetrical recycler: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ratio is : (time on = time off). 85 N/ (+) L/+( )

128 85 Series - Miniature Plug-in imers 7-0 A Approvals (according to type): C S - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: solid wire GOS stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 imer type Colour BLE BLACK BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount Retaining clip (supplied with timer) way jumper link for 94.0, and sockets Identification tag Ø Ø COM NO 76 Ø Ø COM NO 76 Ø 3. 7 Ø COM NO NC 3 3 NC NC COIL COIL COIL FOR 94.0, AND SOCKES: 6-way jumper link for 94.0, and sockets RAED LES: 0 A - 50 V

129 94 Series - Sockets and Accessories for 85 Series imers Approvals (according to type): C S - RADE LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: solid wire stranded wire mm x.5 / x.5 x.5 / x.5 AWG x4 / x6 x4 / x6 imer type Colour BLE BLACK BLE BLACK BLE BLACK Screw terminal socket: panel or 35 mm rail (EN 500) mount Retaining clip (supplied with timer) Ø NO 4 4 NC Ø = = 4 Ø 3 Ø NO 3 3 NC Ø Ø NO NC COIL COIL 4 3 COIL COM COM COM 94.8 Approvals (according to type): C S - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - ORQE: 0.5 Nm - WIRE SRIP LENGH: 9 mm - MAX WIRE SIZE: solid wire stranded wire mm x.5 / x.5 x.5 / x.5 AWG x4 / x6 x4 / x6 imer type 85.0 Colour BLE BLACK Screw terminal socket: panel or 35 mm rail (EN 500) mount Retaining clip (supplied with timer) Ø NC NO COM COIL 5

130 86 Series - imer Modules - Multi-function timer modules - imer module for 90 and 9 series sockets - LED indicator ime scale: from 0.05s to 00 h - Multi-function - Plug-in for use with 90.0, and 9.03 sockets AI: ON delay DI: ON pulse SW: Symmetrical recycler: ON start BE: Signal OFF delay CE: ON delay DE: Signal ON pulse EE: Signal OFF pulse FE: Signal ON delay + OFF pulse 38 B B 54 S ( ~) (+ ~) ( ~) (+ ~) 0,5 6,3 wiring diagram without signal SAR wiring diagram with signal SAR 86 6 Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimun control impulse ms Setting accuracy full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) see 60 and 6 series relays Note: don t use with relay 6.3x.x0.x300 and 6.3x.x0.x ( )s, (0.5 0)s, (5 00)s, (0.5 0)min, (5 00)min, (0.5 0)h, (5 00)h ± ±5 see 60 and 6 series relays IP 0

131 86 Series - imer Modules - Mono-function timer modules - imer module for 90, 9, 94, 95 series sockets - LED indicator Mono-function - Plug-in for use with sockets -Mono-function - Plug-in for use with sockets AI: ON delay DI: ON pulse L/+(-) N/-(+) L/+(-) N/-(+) wiring diagram wiring diagram wiring diagram without signal SAR wiring diagram without signal SAR Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) Breaking capacity in DC: Minimum switching load Standard contact material Supply specifications Nominal voltage Rated power AC/DC Operating range echnical data Specified time range kw 30/0/0V A mw(v/ma) V AC(50/60Hz) V DC mw AC DC Repeatability % Recovery time Minimum control impulse ms ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) see 40, 44, 55, 60 and 6 series relays see 40, 44, 55, 60 and 6 series relays (non polarized) 4 (non polarized) (0.8...) N (0.8...) N (0.8...) N (0.8...) N (.5 5)s,(6 60)s,(0.8 8)min,(6.4 64)min (.5 5)s,(6 60)s,(0.8 8)min,(6.4 64)min ± ± ±5 ±5 see 40, 44, 55, 60 and 6 series relays see 40, 44, 55, 60 and 6 series relays IP 0 IP 0 GOS C S 7

132 86 Series - imer Modules ORDERING INFORMAION Example: a 86 series multi-function timer module with ( to 40) V AC/DC supply voltage Series ype 0 = Multi-function (AI, DI, SW, BE, CE, DE, EE, FE) = Mono-function (AI) = Mono-function (DI) No. of poles see 40, 44, 55, 60 and 6 series relays Supply voltage 04 =...4 V AC/DC (86.0/0 only) 40 =...40 V AC/DC (86.00 only) Supply version 0 = AC (50/60 Hz)/DC COMBINAIONS Number of poles Relay type Socket type imer module / / /44.5/ / / /86.0/ /86.0/ / /86.0/ /86.0/ /86.0 ECHNICAL DAA 86 EMC SPECIFICAIONS YPE OF ES REFERENCE SANDARD /0 ELECROSAIC DISCHARGE - contact discharge EN kv n.a. - air discharge EN kv 8 kv RADIO-FREQENCY ELECROMAGNEIC FIELD ( MHz) EN V/m 0 V/m FAS RANSIENS (burst) (5-50 ns, 5 khz) on Supply terminals EN kv kv SRGES (./50 µs) on Supply terminals - common mode EN kv kv - differential mode EN kv RADIO-FREQENCY COMMON MODE ( MHz) EN V 0 V on Supply terminals RADIAED AND CONDCED EMISSION EN 550 class B class B OHER DAA , 86.0 CRREN ABSORPION on signal control (B) ma POWER LOS IN HE ENVIRONMEN - without contact current W 0. ( V) - (30 V) 0. - with rated current see 60 and 6 series relays see 40, 44, 55, 60, 6 series relays IME SCALES ype ype 86.0 ype 86.0 (.5...5) s (6...60) s ( ) min ( ) min 8 NOE: time scales and functions must be set before energising the timer.

133 Sockets for 86 Series imers FNCIONS LED ype LED ype 86.0/0 Supply voltage NO output contact = Supply Voltage OFF Open S = Signal switch = Output Contact ON ON ON Open Open (timing in progress) Closed Without signal Start= Start via contact in supply line (). With signal Start = Start via contact into control terminal (B). ype Wiring diagram without signal SAR t< (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. B t< (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. ( ~) (+ ~) t< (SW) Symmetrical recycler: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ratio is : (time on = time off). with signal SAR B S S t< (BE) Signal OFF delay. Power is permenently applied to the timer. he output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. ( ~) (+ ~) S S t< (CE) Signal ON and OFF delay. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Signal ON pulse. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset S t< (EE) Signal OFF pulse. Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset S (FE) Signal ON pulse + OFF pulse. Power is permenently applied to the timer. Both the opening and closing of the Signal Switch (S) initiates the transfer of the output contacts. In both instances the contacts reset after the delay period has elapsed. Wiring diagram L/+(-) N/-(+) ype 86.0 t< (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. ype 86.0 t< (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 9

134 Sockets for 86 Series imers Approvals (according to type): GOS - Double terminal (for easy start connection). - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - ORQE: 0.6 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: solid wire stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 Relay type Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount Metal retaining clip imer module 86.00, 86.0, way jumper link for 90.0 and sockets ,5 3, NO NC NC NO ,5 3, 38 NO NO NO NC NC NC COIL COM COM COM COIL SAR NO NC NO NC NO NC ,6 35,5 0,4 6,9 33, COIL COM COIL COM COIL COIL COM COM SAR COM COIL Approvals (according to type): GOS C - RAED LES: 6 A - 50 V - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.8 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: solid wire stranded wire mm x0 / x4 x6 / x4 AWG x8 / x x0 / x Relay type 6.3, 6.33 Colour BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip 09.7 supplied with socket packaging code SMA Metal retaining clip 09.7 imer modules 86.00, 86.0, 86.0 S COM NO 3 3 NC B A COIL

135 Sockets for 86 Series imers Approvals (according to type): GOS C S Relay type , Colour BLE BLACK BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount retaining clip supplied with socket packaging code SMA Metal retaining clip Plastic retaining and release clip way jumper link for 94.0, and sockets Identification tag imer modules 86.0, 86.0 Sheet of marker tags for retaining and release clip RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: 76 Ø 3. Ø Ø 3. Ø Ø 3. Ø solid wire stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x COM NO COM NO COM NO NC 3 3 NC NC COIL COIL COIL Approvals (according to type): GOS C S Relay type , 40.5, 40.6 Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount, retaining clip supplied with socket packaging code SPA Plastic retaining and release clip Metal retaining clip way jumper link for and sockets Identification tag imer modules 86.0, RAED LES: 0 A - 50 V with a current >0 A, the contact terminal must be connected in parallel ( with, 4 with 4, with ) - INSLAION: 6 kv (./50µs) between coil and contacts - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - SCREW ORQE: 0.5 Nm - WIRE SRIP LENGH: 8 mm - MAX WIRE SIZE: 78.6 Ø Ø = = solid wire stranded wire mm x6 / x.5 x4 / x.5 AWG x0 / x4 x / x4 COM 4 NO COM 4 4 NO NC NC COIL COIL

136 87 Series - Modular imers 5-8 A -.5 mm wide - Mono-function and multi-function versions available - ime scales from 0.05s to 60h - delayed contact + instantaneous contact and remote potentiometer version available (type 87.0) - rue OFF delay version (type 87.6/6) - LED indicator - 35 mm rail (EN 500) mount Multi-function - pole - 35 mm rail mounting Multi-function - iming can be regulated using ext. Potentiometer - timed contacts or timed + instantaneous contact - 35 mm rail mounting AI: ON delay DI: ON pulse GI: Fixed pulse delayed SW: Symmetrical recycler: ON start BE: Signal OFF delay CE: Signal ON and OFF Delay DE: Signal ON pulse EE: Signal OFF pulse AI: ON delay DI: ON pulse GI: Fixed pulse delayed SW: Symmetrical recycler: ON start BE: Signal OFF delay CE: Signal ON and OFF Delay DE: Signal ON pulse EE: Signal OFF pulse L/+ 5 L/+ S B 5 L/+ B 5 () 5 L/+ S B 5 () N/ 8 6 N/ Z Z (4 N/ 6 ) Z Z (4 N/ 6 ) wiring diagram (without signal SAR) wiring diagram (with signal SAR) wiring diagram (without signal SAR) wiring diagram (with signal SAR) Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A 87 Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) 3 CO CO 8/30 8/30 50/400 50/400,000, /0.5/0. 8/0.5/ (0/5) 300 (0/5) AgCdO AgCdO /0.5 5/0.5 (0.85.) N (0.85.) N (0.85.) N (0.85.) N See page 37 See page 37 ± ± ±5 ± IP 0 IP 0 GOS C S

137 87 Series - Modular imers 5-8 A -.5 mm wide - Mono-function and multi-function versions available - ime scales from 0.05s to 60h - delayed contact + instantaneous contact and remote potentiometer version available (type 87.0) - rue OFF delay version (type 87.6/6) - LED indicator - 35 mm rail (EN 500) mount Mono-function - 35 mm rail mounting -Mono-function - 35 mm rail mounting -Mono-function - 35 mm rail mounting AI: ON delay DI: ON pulse SW: Symmetrical recycler: ON start L/+ L/+ L/ N/ 8 6 N/ 8 6 N/ wiring diagram (without signal SAR) wiring diagram (without signal SAR) wiring diagram (without signal SAR) Contact specifications Contact configuration CO CO CO Rated current/maximum peak current A 8/30 8/30 8/30 Rated voltage/maximum switching voltage V AC 50/400 50/400 50/400 Rated load in AC,000,000,000 Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: Minimum switching load 30/0/0V A mw(v/ma) 8/0.5/0. 8/0.5/ (0/5) 300 (0/5) 8/0.5/ (0/5) 87 Standard contact material AgCdO AgCdO AgCdO Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC (50Hz)/W 5/0.5 5/0.5 5/0.5 Operating range AC (0.85.) N (0.85.) N (0.85.) N DC (0.85.) N (0.85.) N (0.85.) N echnical data Specified time range See page 37 See page 37 See page 37 Repeatability % ± 0. ± 0. ± 0. Recovery time ms Minimum control impulse ms Setting accuracy-full range % ±5 ±5 ±5 Electrical life at rated load in AC cycles Ambient temperature range C Protection category IP 0 IP 0 IP 0 Approvals: (according to type) GOS C S 33

138 87 Series - Modular imers 5-8 A -.5 mm wide - Mono-function and multi-function versions available - ime scales from 0.05s to 60h - delayed contact + instantaneous contact and remote potentiometer version available (type 87.0) - rue OFF delay version (type 87.6/6) - LED indicator - 35 mm rail (EN 500) mount Mono-function - 35 mm rail mounting -Mono-function - pole - 35 mm rail mounting -Mono-function - pole - 35 mm rail mounting BE: Signal OFF delay BI: rue OFF delay BI: rue OFF delay L/+ * S L/+ L/+ B N/ 8 6 N/ N/ wiring diagram (with signal SAR) wiring diagram (without signal SAR) wiring diagram (without signal SAR) Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) CO CO CO 8/30 5/0 5/0 50/400 50/400 50/400,000,50, /0.5/0. 5/0.5/0. 5/0.5/ (0/5) 300 (0/5) 300 (0/5) AgCdO AgCdO AgCdO /0.5.5/.5.5/.5 (0.85.) N (0.85.) N (0.85.) N (0.85.) N (0.85.) N (0.85.) N See page 37 See page 37 See page 37 ±0. ± ± ms ( - ) 300 ms ( - ) ±5 ±5 ± IP 0 IP 0 IP 0 GOS C S

139 87 Series - Modular imers 5-8 A -.5 mm wide - Mono-function and multi-function versions available - ime scales from 0.05s to 60h - delayed contact + instantaneous contact and remote potentiometer version available (type 87.0) - rue OFF delay version (type 87.6/6) - LED indicator - 35 mm rail (EN 500) mount Mono-function: Star - delta - pole - 35 mm rail mounting Multi-function - 35 mm rail mounting SD: Star - delta LI: Asymmetrical recycler LE: Signal asymmetrical (ON starting) recycler (ON starting) PI: Asymmetrical recycler PE:Signal asymmetrical (OFF starting) recycler (OFF starting) L/+ L/+ L/+ S 7 B 5 B N/ 8 6 N/ 8 6 N/ star - delta wiring diagram (without signal SAR) wiring diagram (without signal SAR) wiring diagram (with signal SAR) Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) NO CO 8/30 8/30 50/400 50/400,000, /0.5/0. 8/0.5/ (0/5) 300 (0/5) AgCdO AgCdO /0.5 5/0.5 (0.85.) N (0.85.) N (0.85.) N (0.85.) N See page 37 See page 37 ± 0. ± ±5 ± IP 0 IP 0 GOS C S 87 35

140 87 Series - Modular imers 5-8 A ORDERING INFORMAION Example: 87 series 8 A multi-function timer, CO contact, with (4 40) V AC (50/60) Hz and (4 48) V DC supply Series ype 0 = Multi-function (AI, BE, CE, DI, DE, EE, GI, SW, ON, OFF) = ON delay (AI) = ON pulse (DI) 3 = Symmetrical recycler: ON start (SW) 4 = Signal OFF delay (BE) 6 = rue OFF delay (power OFF) (BI) 8 = Star - delta (SD) 9 = Asymmetrical recycler (LI, LE, PI, PE) Supply voltage 40 = { 4 48 V DC 4 40 V AC 40 = 4 40 V AC/DC for 87.6 and 87.6 Supply version 0 = AC (50/60 Hz)/DC No. of poles = pole = pole for 87.0/6 = NO for ECHNICAL DAA EMC SPECIFICAIONS YPE OF ES REFERENCE SANDARD ELECROSAIC DISCHARGE - contact discharge EN kv - air discharge EN kv RADIO-FREQENCY ELECROMAGNEIC FIELD ( MHz) EN V/m FAS RANSIENS (burst) (5-50 ns, 5 khz) on Supply terminals EN kv SRGES (./50 µs) on Supply terminals - common mode EN kv - differential mode EN RADIO-FREQENCY COMMON MODE ( MHz)on Supply terminals EN V RADIAED AND CONDCED EMISSION EN 550 class B OHER DAA SIGNAL CONROL (B) - current absorption ma - max cable lenght 50 m (capacity of 0 nf / 00 m) POWER LOS O HE ENVIRONMEN 87.0/0///3/4/9 87.6/ without contact current W with rated current W MAX WIRE SIZE solid cable stranded cable SCREW ORQE Nm. mm x4 / x.5 x4 / x.5 AWG x / x4 x / x6 36

141 IME SCALES ype Function Code Function 87 Series - Modular imers 5-8 A s s s min min min h h h h / AI ON delay 87.0 BE Signal OFF delay CE Signal ON and OFF delay DI ON pulse DE Signal ON pulse EE Signal OFF pulse GI Fixed pulse (0,5s) delayed SW Symmetrical recycler: ON start 87. AI ON delay 87. DI ON pulse 87.3 SW Symmetrical recycler: ON start 87.4 BE Signal OFF delay 87.6/ BI rue OFF delay (power OFF) SD Star - delta ( = ~60 ms) 87.9 LI Asymmetrical recycler (ON starting) LE Signal asymmetrical recycler (ON starting) PI Asymmetrical recycler (OFF starting) PE Signal asymmetrical recycler (OFF starting) NOE: time scales and functions must be set before energising the timer

142 87 Series - Modular imers 5-8 A FNCIONS LED** Green iming NO output contact Open imed Closed Contacts DIP switch Instantaneous* Open Closed = Supply Voltage S = Signal switch C = Output Contact None In progress In progress None Open Open Closed Closed * 5-6* * 5-6* * 5-8* * 5-8* p Down - 4* - * - * - * - * - 4* - 4* - 4* * only for type 87.0 with timed contacts. --4 only for type 87.0 with instantaneous contact + timed positioning the front DIP switch. ** he LED on types 87.6 and 87.6 is illuminated when supply voltage is supplied to timer. Without signal Start= Start via contact in supply line (). With signal Start = Start via contact into control terminal (B). Wiring diagram Multi-function without signal SAR L/+ 5 ype C t< (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 8 6 N/ 87.0 L/+ () B 5 5 C C t< 0.5s (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. (GI) Fixed pulse (0.5s) delayed. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5s. 0.5s. Z Z (4 ) ** N/ 87.0 C t< (SW) Symmetrical recycler: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ratio is : (time on = time off). with signal SAR L/+ * S B 5 S C t< (BE) Signal OFF delay. Power is permenently applied to the timer. he output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset N/ L/+ * S B () 5 Z Z (4 ) ** N/ 87.0 * A voltage other than the C supply voltage can be applied to the command SAR (B). Example: - = 30 V AC ON B - = 4 V AC C ** ype 87.0: regulated using an external potentiometer OFF (0 kω W). C NB.: remove link between Z-Z and position the imer potentiometer on zero. 38 S C S C S t< t< t< (CE) Signal ON and OFF delay. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Signal ON pulse. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. (EE) Signal OFF pulse. Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. Permanently ON. Selecting the function ON when power is applied to the relay the first contact transfers immediately and remains in that position. Permanently OFF. he contact returns to the original position when the OFF function is selected.

143 87 Series - Modular imers 5-8 A FNCIONS Wiring diagram ype Monofunction without signal SAR L/+ 87. C t< (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed C t< (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. N/ C t< (SW) Symmetrical recycler: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ratio is : (time on = time off). L/ C (BI) rue OFF delay (power OFF). Apply power to timer (minimum 300ms). Output contacts transfer immediately. Removal of power initiates the preset delay, after which time the output contacts reset. 8 8 N/ u= 60 ms (SD) Star - delta. Apply power to timer. he star contact ( ) closes immediately. After preset delay has elapsed the star contact ( ) resets. After a further fixed time of ~60 ms the delta contact ( ) closes and remains in that position, until reset on power off. with signal SAR (S) L/+ * S B S C t< (BE) Signal OFF delay. Power is permenently applied to the timer. he output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. 8 6 N/ 87.4 Asymmetrical recycler without signal SAR L/ switch position C t< (LI) Asymmetrical recycler (ON starting). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ON and OFF times are independently adjustable. 87 B N/ 87.9 switch position C t< (PI) Asymmetrical recycler (OFF starting). Apply power to timer. Output contacts transfer after time has elapsed and cycle between OFF and ON for as long as power is applied. he ON and OFF times are independently.. adjustable. with signal SAR (S) L/+ * S B 5 switch position S C t< (LE) Signal asymmetrical recycler (ON starting) Power is permenently applied to the timer. Closing Signal Switch (S) causes the output contacts to transfer immediately and cycle between ON and OFF, until opened. 8 6 N/ 87.9 switch position S C t< (PE) Signal asymmetrical recycler (OFF starting). Power is permenently applied to the timer. Closing the Signal Switch (S) initiates delay after which the output contacts transfer and continue to cycle between OFF and ON, until the Signal Switch is opened. 39

144 88 Series - Plug-in imers 5-8 A pin plug-in version available - Multi-voltage and multi-function versions available - ime scales from 0.05s to 00h - delayed contact + instantaneous contact version available (type 88.) - Front panel mount - Sockets: 90 series Multi-function - pin - Plug-in for use with 90 series sockets - Multi-function -8 pin, timed contacts or timed + instantaneous contact - Plug-in for use with 90 series sockets 48 AE: Signal ON delay BE: Signal OFF delay DE: Signal ON pulse with signal SAR Al a: ON Delay ( timed contacts) Al b: ON Delay ( timed + instantaneous contact) Dl a: ON Pulse ( timed contacts) Dl b: ON Pulse ( timed + instantaneous contact) L/+ N/ S/R AI: ON delay HI: ON pulse SW: Symmetrical recycle: ON start without signal SAR without signal SAR N/ L/+ C C L/+ N/ Contact specifications Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity in DC: 30/0/0V A Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC(50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy-full range % Electrical life at rated load in AC cycles Ambient temperature range C Protection category Approvals: (according to type) CO CO 8/5 5/0 50/50 50/400,000, /0.3/0. 5/0.3/ (5/5) 500 (5/5) AgNi AgCdO (30 V)/ (4 V) 9 (30 V)/ (4 V) (0.05s 5h) - (0.05s 0h) - (0.05s 50h) - (0.05s 00h) ± ± ±3 ± IP 40 IP 40 GOS

145 88 Series - Plug-in imers 5-8 A ORDERING INFORMAION Example: 88 series multi-function timer, CO contact 8 A, with (4 30) V AC (50/60) Hz and (4 30) V DC supply Series ype 0 = Functions AI, SW, AE, BE, DE, HI = Functions Al a, Al b, Dl a, Dl b No. of poles = pole Supply version 0 = AC (50/60 Hz)/DC Special versions 0 = Standard for type 88. = Standard for type 88.0 Supply voltage 4 30 V AC 30 = { (for type 88.) 4 48 V DC 30 = 4 30 V AC/DC (for type 88.0) ECHNICAL DAA EMC SPECIFICAIONS YPE OF ES REFERENCE SANDARD ELECROSAIC DISCHARGE - contact discharge EN kv - air discharge EN kv RADIO-FREQENCY ELECROMAGNEIC FIELD ( MHz) EN V/m FAS RANSIENS (burst) (5-50 ns, 5 khz) on Supply terminals EN kv/5 kv SRGES (./50 µs) on Supply terminals - common mode EN kv - differential mode EN kv RADIO-FREQENCY COMMON MODE ( MHz) EN V on Supply terminals IME SCALES END SCALE s min h x0 h s 0.5 min 0.5 h 5 h s min h 0 h 5 5 s 5 min 5 h 50 h 0 0 s 0 min 0 h 00 h NOE: time scales and functions must be set before energising the timer. IME SCALES AND FNCIONS SELECION E Function selector AE, AI, BE, DE, HI, SW AI a, AI b, DI a, DI b D ime scale selector 0.5,, 5, 0 0.5,, 5, 0 H nit of time selector s, min, h, 0h s, min, h, 0h 4

146 88 Series - Plug-in imers 5-8 A FNCIONS = Supply Voltage S = Signal switch C = Output Contact Without signal Start= Start via contact in supply line (). With signal Start = Start via contact into control terminal (6/). ype 88.0 Wiring diagram without signal SAR C t< (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed L/+ N/ C t< (SW) Symmetrical recycler: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. he ratio is : (time on = time off). S C t< (AE) ON delay. When power is applied, the timer will function as an ON delay except when the Signal Switch (S) is closed which will force the output and the timing process into the reset condition. with signal SAR L/+ N/ S/R S C t< (BE) Signal OFF delay. Power is permenently applied to the timer. he output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. S C t< (DE) Signal ON pulse. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. without signal SAR L/+ N/ S C (HI) ON pulse. Apply power to timer. Output contacts transfer immediately After preset time has elasped, contacts reset. N.B. Ensure a fixed connection between erminals and 6. ype C C (Al a) ON Delay ( timed contacts). Apply power to timer. Contacts (C and C ) transfer after preset time has elasped. Reset occurs when power is removed. without signal SAR C C (Al b) ON Delay ( timed contact + instantaneous contact). Apply power to timer. Output contact (C ) transfers immediately. Contact (C ) transfers after the preset time has elasped. Reset occurs when power is removed. N/ L/+ C C C C (Dl a) ON pulse ( timed contacts). Apply power to timer. Output contacts (C and C ) transfer immediately. After preset time has elasped, the contacts reset. C C (Dl b) ON pulse ( timed contact + instantaneous contact). Apply powert to timer. Output contacts (C and C ) transfer immediately. After preset time has elasped, the contact (C ) resets. Contact (C ) resets when power is removed. 4

147 CERIFICACION DE CONFORMIDAD DE LA FABRICACION CERIFICACION DE CONFORMIDAD DE LA FABRICACION 90 Series - Sockets and Accessories for 88 Series imers imer type Colour BLE BLACK BLE BLACK Clamp terminal socket: panel or 35 mm rail (EN 500) mount Approvals (according to type): GOS - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - ORQE: 0.5 Nm - WIRE SRIP LENGH: 0 mm - MAX WIRE SIZE: C S NO NC NC NO NO NC NO NC NO NC solid wire stranded wire mm x6 / x.5 x6 / x.5 AWG x0 / x4 x0 / x4 7 8 COIL COM COM COIL COILCOM COM COM COIL imer type Colour BLE BLACK BLE BLACK Screw terminal socket: panel or 35 mm rail (EN 500) mount Approvals (according to type): Ø 8. = 35 GOS C S = - RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - PROECION CAEGORY: IP 0 - AMBIEN EMPERARE: ( ) C - ORQE: 0.8 Nm - WIRE SRIP LENGH: mm - MAX WIRE SIZE: solid wire stranded wire mm x4 / x.5 x4 / x.5 AWG x / x4 x / x NO NC NC NO COIL COMCOM COIL NO 43 NC NO com NC 5 NC NO COIL COM COM COIL imer type Colour BLE BLACK BLE BLACK Sockets 8- pin backwired with solder terminals Approvals (according to type): 3.5 Ø 3 GOS RAED LES: 0 A - 50 V - DIELECRIC SRENGH: kv AC - AMBIEN EMPERARE: ( ) C

148 0 Series - Light Dependent Relays - 6 A - A range of light dependent relays with or NO contacts - Pole or flange mounting - Double break (phase + neutral) type available (type 0.3) - Sensitivity adjustment from to 50 lux NO, 6 A - Pole mount - NO, A - Pole mount Ø = = = = R 60 R Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) W uncompensated fluorescent (30V) W halogen (30V) W Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC (50Hz) DC echnical data Electrical life at rated load in AC cycles hreshold setting lx lx Delay time: switching ON/OFF s Ambient temperature range C Protection category Approvals: (according to type) NO NO 6/30 (00 A - 5 ms) /5 (00 A - 5 ms) 30/ 30/ 3,700, ,000, , ,000,00,000 (0/0),000 (0/0) AgSnO AgSnO / / (0.85.) N (0.8.) N (switching ON) 80 (switching ON) 50 (switching OFF) 50 (switching OFF) 6/5 5/ IP 54 IP 54 GOS

149 ORDERING INFORMAION 0 Series - Light Dependent Relays - 6 A Example: a 0 series light dependent relay with NO - A contact and screw terminal connections, with 30 V AC supply Series ype 3 = Pole mount - NO 4 = Pole mount - NO Supply voltage 30 = 30 V Supply version 8 = AC (50/60 Hz) No. of poles = Single phase switch NO, A = Double phase switch NO, 6 A ECHNICAL DAA INSLAION DIELECRIC SRENGH - between open contacts V AC,000,000 OHER DAA CABLE GRIP Ø mm 0.3 (8.9 3) 0.4 (8.9 3) PRESE HRESHOLD lx 5 switch ON / 0 switch OFF 3 switch ON / 8 switch OFF MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x6 / x4 x6 / x.5 x6 / x4 x6 / x.5 AWG x0 / x x0 / x4 x0 / x x0 / x4 SCREW ORQE Nm.. WIRING DIAGRAMS L L N N 30 ~ 0 ype 0.3 ype

150 Series - Modular Light Dependent Relays 6 A - ype.0 is suitable for use on staircases and in entrance halls. Selector with 3 positions: - high range (threshold setting lx) - low range (threshold setting...30lx) - continuous light (particularly interesting for the est at the first installation). - ype.7: with CO contact and with...4 C/DC voltage supply. - SELV separation between contact and supply circuit. - Supplied with separate sensitive photocell. - LED indication mm rail (EN 500) mount. - pole - 35 mm rail mount - zero hysteresis pole - 35 mm rail mount - low voltage version available 35 B B B B Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) W uncompensated fluorescent (30V) W halogen (30V) W Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V DC/AC (50/60Hz) V AC (50/60Hz) Rated power AC/DC (50Hz)/W Operating range DC/AC (50Hz) AC (50Hz) echnical data Electrical life at rated load in AC cycles hreshold setting lx lx Delay time: switching ON/OFF s Ambient temperature range C Protection category: light dependent relay/photocell Approvals: (according to type) CO CO 6/30 (00 A - 5 ms) 6/30 (00 A - 5 ms) 50/400 50/400 4,000 4, ,000 (NO contact),000 (NO contact) 550 (NO contact) 550 (NO contact),000 (NO contact),000 (NO contact),000 (NO contact),000 (NO contact),000 (0/0),000 (0/0) AgSnO AgSnO /.3/0.8 ( ) V (0.8.) N (88 37) V (84 64) V (low range) 00 (switching ON) 0,000 (high range) 50 (switching OFF) 5/5 5/ IP 0/IP 54 IP 0/IP 54 GOS

151 ORDERING INFORMAION Series - Modular Light Dependent Relays 6 A Example: a series light dependent relay zero hysteresis with CO - 6 A contact and 35 mm rail mounting, with 30 V AC supply Series ype 0 = 35 mm rail (EN 500) mounting, zero hysteresis 7 = 35 mm rail (EN 500) mounting No. of poles = pole Supply voltage 04 =...4 V AC/DC for.7 only 5 = V AC for.7 only 30 = V AC for.7 only 30 = 30 V AC for.0 only Supply version 0 = AC (50/60 Hz)/DC for only 8 = AC (50/60 Hz) ECHNICAL DAA INSLAION.0.7 DIELECRIC SRENGH - between supply and contacts V AC 4,000 4,000 - between open contacts V AC,000,000 OHER DAA.0.7 CABLE GRIP of SENSIIVE PHOOCELL Ø mm (7.5 9) (7.5 9) CABLE LENGH m 50 (x.5mm ) PRESE HRESHOLD lx 0 00 POWER LOS O HE ENVIRONMEN - without contact current W with rated current W 3. MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x6 / x4 x6 / x.5 x6 / x4 x6 / x.5 AWG x0 / x x0 / x4 x0 / x x0 / x4 SCREW ORQE Nm

152 I I I I I I I I I I I I I I I I I I I I I I I I WIRING DIAGRAMS Series - Modular Light Dependent Relays 6 A ype.0 RED LED indication: Blinking = power ON, relay OFF Continuous = power ON, relay ON L N B B ype.7 RED LED indication: Slow blinking = power ON, relay OFF Fast blinking = power ON, timing in progress Continuous = power ON, relay ON L N B B 4 4 ype.0 ZERO HYSERESIS LIGH DEPENDEN RELAYS I I I I I I I I I I RADIIONAL LIGH DEPENDEN RELAYS I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I OFF OFF threshold ON/OFF threshold ON OFF t set threshold ON t ON threshold Switch OFF level = Switch ON level. Patented "Zero Hyseresis" circuitry ensures reliable switching without wasting energy. raditional light dependent relays incorporate switching hysteresis to prevent malfunctioning or tripping. his results in an unnecessary delay in switching off,and a resulting waste of energy (over period ). ACCESSORIES Sensitive photocell (supplied with light dependent relay)

153 Series - ime Switches 6 A - ypes available: - type.0 - mechanical daily time switch - type.//7 - digital weekly time switch mm wide (type.7) - 35 mm rail (EN 500) mount - Internal battery for the set up without supply (types.//7) - Impulse function (...59s) (types.//7) - Automatically adjusts for daylight saving (types.//7) mechanical daily time switch - CO - 35 mm rail mount - digital weekly time switch - CO - 35 mm rail mount - digital weekly time switch - CO - 35 mm rail mount M M M ~ ~ 3 3 L N L N M L M L M 3 3 M N 3 M N Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) W uncompensated fluorescent (30V) W halogen (30V) W Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC (50Hz) DC echnical data Electrical life at rated load in AC cycles ype of time switch Programs Minimum interval setting min Accuracy s/day Ambient temperature range C Protection category Approvals: (according to type) CO CO CO 6/ 6/30 6/30 50/ 50/ 50/ 4,000 4,000 4, ,000 (NO contact),000 (NO contact),000 (NO contact) 750 (NO contact) 40 (NO contact) 40 (NO contact),000 (NO contact),000 (NO contact),000 (NO contact),000 (NO contact),000 (NO contact),000 (NO contact),000 (0/0),000 (0/0),000 (0/0) AgCdO AgCdO AgCdO /.4/.4 / / (0.85.) N (0.9...) N (0.85.) N (0.85.) N (0.9...) N daily weekly weekly 48 switching point IP 0 IP 0 IP 0 GOS 49

154 Series - ime Switches 6 A - ypes available: - type.0 - mechanical daily time switch - type.//7 - digital weekly time switch mm wide (type.7) - 35 mm rail (EN 500) mount - Internal battery for the set up without supply (types.//7) - Impulse function (...59s) (types.//7) - Automatically adjusts for daylight saving (type.//7).7 - digital weekly time switch - CO - 35 mm rail mount M 3 L N Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) W uncompensated fluorescent (30V) W halogen (30V) W Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC (50Hz) DC echnical data Electrical life at rated load in AC cycles ype of time switch Programs Minimum interval setting min Accuracy s/day Ambient temperature range C Protection category Approvals: (according to type) CO 6/30 50/ 4,000 40,000 (NO contact) 750 (NO contact),000 (NO contact),000 (NO contact),000 (0/0) AgCdO 30 / (0.85.) N weekly IP 0 GOS

155 Series - ime Switches 6 A ORDERING INFORMAION Example: a series, mechanical daily time switch, CO - 6 A, supply voltage 30 V AC. Series ype 0 = Daily = Weekly, 35.8 mm wide 7 = Weekly, 7.5 mm wide No. of poles = CO, 6 A = CO, 6 A (for. only) Supply voltage 04 = 4 V AC/DC 30 = 30 V Supply version 0 = AC (50/60 Hz)/DC (for only) 8 = AC (50/60 Hz) ECHNICAL DAA INSLAION.0././.7 DIELECRIC SRENGH - between open contacts V,000,000 OHER DAA POWER BACK-P.0 70 h after 80 h uninterrupted supply././.7 6 years after the first operation POWER LOS O HE ENVIRONMEN - without contact current W.5 - with rated current W.5 3 ( CO) 4 ( CO) MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x6 / x4 x6 / x.5 x6 / x4 x6 / x.5 AWG x0 / x x0 / x4 x0 / x x0 / x4 SCREW ORQE Nm.. WIRING DIAGRAMS L L L N N N B L M 3 M 3 M A 3 N N L ype.0 SELECOR SWICH: I Permanently OFF (O) Automatic (AO) Permanently ON (I) ype.. ype.7 5

156 3 Series - Electronic Step Relays 0-6 A - Electronic step relays - Control circuit can be used continuously - Longer mechanical and electrical life, and much quieter than electromechanical step relays - Suitable for SELV applications (according to IEC 364), type mm rail (EN 500) or flange mount - Low voltage supply -4 V, type Low voltage supply -4 V - Step or monostable relay - 35 mm rail mount 35 - NO - Panel mount - Screw terminals B B 4 B L 3 N Contact specifications Contact configuration Rated current/max. peak current Rated voltage/max. switching voltage Rated load in AC Rated load in AC5 (30 C) A V AC Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) uncompensated fluorescent (30V) halogen (30V) Minimum switching load Standard contact material Supply specifications Nominal voltage Rated power AC/DC Operating range echnical data W W W mw(v/ma) V AC (50/60Hz) V DC V AC (50Hz)/W AC (50Hz) DC Electrical life at rated load in AC cycles Maximum impulse duration Dielectric strength between: open contacts V AC supply - contacts V AC Ambient temperature range C Protection category Approvals: (according to type) 58 NO NO 6/30 (00 A - 5 ms) 0/0 (00 A - 5 ms) 50/400 30/ 4,000, ,000, , ,000,000,000 (0/0),000 (0/0) AgSnO AgSnO /.5.5/ (0.8.) N (0.85.5) N (0.9.) N continuous continuous,000,000 4, IP 0 IP 0 GOS GOS

157 ORDERING INFORMAION 3 Series - Electronic Step Relays 0-6 A Example: a 3 series, electronic step or monostable relay, 35 mm rail mount and NO - 6 A contact, with 30 V AC supply Series ype 0 = 35 mm rail (EN 500) mount 7 = Panel mount No. of poles = Single phase switch NO Supply voltage 0 = V AC/DC 04 = 4 V AC/DC 5 = 0 5 V AC 30 = V AC (3.7 only) 30 = 30 C (3.7 only) Supply version 0 = AC (50/60 Hz)/DC (for and only) 8 = AC (50/60 Hz) ECHNICAL DAA INSLAION DIELECRIC SRENGH - between control circuit and supply V AC 4,000 - between control circuit and contacts V AC 4,000 4,000 - between supply and contacts V AC 4,000 4,000 - between open contacts V AC,000,000,000 OHER DAA POWER LOS O HE ENVIRONMEN - without contact current W with rated current W MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x6 / x4 x6 / x.5 x4 / x.5 x.5 / x.5 AWG x0 / x x0 / x4 x / x4 x4 / x4 SCREW ORQE Nm

158 3 Series - Electronic Step Relays 0-6 A WIRING DIAGRAMS L L N N B B B B 4 B3 4 B3 ype 3.0 Bistable (step) wiring diagram ype 3.0 Monostable wiring diagram L L N N 4 L 3 N 4 L 3 N ype wire connection Max 5 ( ma) illuminated push buttons ype wire connection Max 5 ( ma) illuminated push buttons 3 54

159 4 Series - Electronic Staircase imer 6 A - One module (7.4 mm) wide - ime range from 30 s to 0 min - Can be used with illuminated push - buttons - Suitable for 3 or 4 wiring systems - LED indicators - 35 mm rail (EN 500) mount Multi-function - NO - 35 mm rail mount - For 3 or 4 wiring system - NO - 35 mm rail mount N 3 N 3 84 L L Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) W uncompensated fluorescent (30V) W halogen (30V) W Minimum switching load mw(v/ma) Standard contact material Supply specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC (50Hz) DC echnical data Electrical life at rated load in AC cycles Delay setting min Max no. of illuminated push-button ( ma) Maximum impulse duration Ambient temperature range C Protection category Approvals: (according to type) NO NO 6/30 (00 A - 5 ms) 6/30 (00 A - 5 ms) 30/ 30/ 3,700 3, ,000, ,000,000,000,000,000 (0/0),000 (0/0) AgSnO AgSnO /.5/ (0.8.) N (0.8.) N continuous continuous IP 0 IP 0 GOS 4 55

160 ORDERING INFORMAION 4 Series - Electronic Staircase imer 6 A Example: a 4 series single module relay with a single phase switch NO - 6 A contact, with supply rated at 30 V AC Series ype 0 = 35 mm rail (EN 500) mount, multi-function 7 = 35 mm rail (EN 500) mount Supply voltage 30 = 30 V Supply version 8 = AC (50/60 Hz) No. of poles = Single phase switch, 6 A ECHNICAL DAA INSLAION DIELECRIC SRENGH - between open contacts V AC,000,000 OHER DAA POWER LOS O HE ENVIRONMEN - without contact current W.3 - with rated current W MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x6 / x4 x4 / x.5 x6 / x4 x4 / x.5 AWG x0 / x x / x4 x0 / x x / x4 SCREW ORQE Nm WIRING DIAGRAMS ype4.0 LED indication: red = relay ON green = power ON L N N 3 L N N 3 L 4 L 4 3 wire connection 4 wire connection 4 ype 4.7 LED indication: red = relay ON L N N 3 L N N 3 L 4 L 4 3 wire connection 4 wire connection 56

161 4 Series - Electronic Staircase imer 6 A FNCIONS ype he following functions are selected by means of a DIP SWICH: iming step relay ON Step relay ON Push-button Push-button Relay Relay Light constantly ON (If the Dip switch is changed, the output contact transer immediately) ON Staircase relay ON Push-button Push-button Relay Relay ype he following functions are selected by means of a SELECOR SWICH: Light constantly ON Staircase relay Push-button Push-button Relay. When the DIP switch is changed from one position to another, the new function comes into effect immediately. It is not therefore necessary to operate the push button again.. he light constantly ON function can also be attained when the dip switch is set to the staircase timer setting. o do this, either keep the push-button pressed for the desired time or install a standard one-way switch in parallel to the push-button. Relay 4 57

162 0 Series - Modular Step Relays 6 A - One module (7.4mm) wide - est button with mechanical indicators - 6 functions available - AC and DC coils - Identification label - Possible to connect illuminated push buttons - 35 mm rail (EN 500) mount 0. 0., 4, 6, Single phase switch NO - 35 mm rail mount - Double phase switch - 35 mm rail mount - Double phase switch - NC + NO - 35 mm rail mount Contact specifications Number of contacts Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) W uncompensated fluorescent (30V) W halogen (30V) W Minimum switching load mw(v/ma) Standard contact material Coil specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC V DC echnical data Mechanical life cycles Electrical life at rated load in AC cycles Minimum/Maximum impulse duration Insulation between coil and contacts (./50µs) kv Ambient temperature range C Protection category Approvals: (according to type) NO NO NC + NO 6/30 6/30 6/30 50/400 50/400 50/400 4,000 4,000 4, ,000,000, ,000,000,000,000,000,000,000 (0/0),000 (0/0),000 (0/0) AgNi AgNi AgNi /5 6.5/5 6.5/5 (0.85.) N (50Hz)/(0.9.) N (60Hz) (0.9.) N (0.9.) N (0.9.) N s/h (according to EN60669) 0.s/h (according to EN60669) 0.s/h (according to EN60669) IP 0 IP 0 IP 0 GOS RINA C S

163 0 Series - Modular Step Relays 6 A ORDERING INFORMAION Example: a 0 series 35 mm rail (EN 500) mount relay with double phase switch, NO - 6 A contacts, coil rated at V DC and with AgSnO contacts Series ype = 35 mm rail (EN 500) mount No. of poles = Single phase switch NO = Double phase switch NO 3 = Double phase switch NC + NO 4 = 4 sequence double phase switch NO 6 = 3 sequence double phase switch NO 8 = 4 sequence double phase switch NO Contact material 0 = AgNi standard 4 = AgSnO Coil voltage see coil specifications Coil version 8 = AC (50/60 Hz) 9 = DC ECHNICAL DAA INSLAION DIELECRIC SRENGH - between supply and contacts V AC 3,500 - between open contacts V AC,000 - between adjacent contacts V AC,000 OHER DAA 0., 0.3, , 0.4, 0.6 POWER LOS O HE ENVIRONMEN - with rated current W.3.6 COIL CLAMPS CONAC CLAMPS MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x4 / x.5 x.5 / x.5 x6 / x4 x4 / x.5 AWG x / x4 x4 / x4 x0 / x x / x4 SCREW ORQE Nm If the coil is operated for a prolonged period of time, adaquate ventilation of the relays must be provided, for example leaving a gap of about 9mm between relays. COIL SPECIFICAIONS AC VERSION DAA Nominal Coil code Operating range Resistance Consumption voltage N min max R I at N (50Hz) YPE Number of steps SEQENCES 3 4 V V V Ω ma , , DC VERSION DAA Nominal Coil code Operating range Resistance Consumption voltage N min max R I at N V V V Ω ma ,

164 0 Series - Modular Step Relays 6 A WIRING DIAGRAMS L N 3 4 ACCESSORIES MODLE FOR ILLMINAED PSH-BONS Ø ype Sealed version, 7.5 cm insulated and flexible terminals. Example of wiring diagram of type his module is necessary if using up to a maximum of 5 illuminated pushbuttons (.5 ma max, 30 V AC) in the switching input circuit. It must be be connected in parallel to the coil of the relay (see diagram). Sheet of marker tags (4 tags): 9x7mm

165 Series - Modular Monostable Relays 0 A - One module (7.4mm) wide - est button - Identification label - AC and DC coils - 35 mm rail (EN 500) mount.. - Single phase switch NO - 35 mm rail mount - Double phase switch NO - 35 mm rail mount Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity DC: 30/0/0 V A Minimum switching load mw(v/ma) Standard contact material Coil specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC (50Hz) DC echnical data Mechanical life cycles Electrical life at rated load in AC cycles Operate/release time ms Maximum impulse duration Insulation between coil and contacts (./50µs) kv Ambient temperature range C Protection category Approvals: (according to type) NO NO 0/30 0/30 50/400 50/400 5,000 5,000,000,000 0/0.3/0. 0/0.3/0.,000 (0/0),000 (0/0) AgSnO AgSnO /.5 3/.5 (0.85.) N (0.85.) N (0.9.) N (0.9.) N /8 5/8 continuous continuous IP 0 IP 0 GOS 6

166 Series - Modular Monostable Relays 0 A - One module (7.4mm) wide - est button - Identification label - AC and DC coils - 35 mm rail (EN 500) mount Double phase switch NO + NC - 35 mm rail mount - Double phase switch NC - 35 mm rail mount Contact specifications Contact configuration Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Single phase motor rating (30 C) kw Breaking capacity DC: 30/0/0 V A Minimum switching load mw(v/ma) Standard contact material Coil specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC (50Hz) DC echnical data Mechanical life cycles Electrical life at rated load in AC cycles Operate/release time ms Maximum impulse duration Insulation between coil and contacts (./50µs) kv Ambient temperature range C Protection category Approvals: (according to type) NO + NC NC 0/30 0/30 50/400 50/400 5,000 5,000,000,000 0/0.3/0. 0/0.3/0.,000 (0/0),000 (0/0) AgSnO AgSnO /.5 3/.5 (0.85.) N (0.85.) N (0.9.) N (0.9.) N /8 5/8 continuous continuous IP 0 IP 0 GOS

167 ORDERING INFORMAION Series - Modular Monostable Relays 0 A Example: a series 35 mm rail mount relay with NO - 0 A contacts, with coil rated at 4 V DC, contact material AgSnO Series ype = 35 mm rail (EN 500) mount No. of poles = NO = NO 3 = NO + NC 4 = NC Contact material 4 = AgSnO Coil voltage see coil specifications Coil version 8 = AC (50/60 Hz) 9 = DC ECHNICAL DAA CONAC SPECIFICAIONS NOMINAL RAE LAMPS - incandescent (30V) W,000 INSLAION - compensated fluorescent (30V) W 360 DIELECRIC SRENGH - between supply and contacts V AC 3,500 - between open contacts V AC,000 - between adjacent contacts V AC,000 OHER DAA.,.3.,.4 BONCE IME: NO/NC ms 5/0 5/0 POWER LOS O HE ENVIRONMEN - without contact current W.. - with rated current W MAX WIRE SIZE COIL CLAMPS CONAC CLAMPS solid cable stranded cable solid cable stranded cable mm x4 / x.5 x.5 / x.5 x6 / x6 x6 / x4 AWG x / x4 x4 / x4 x0 / x0 x0 / x SCREW ORQE Nm If the coil is operated for a prolonged period of time, adaquate ventilation of the relays must be provided, for example leaving a gap of about 9mm between pairs of relays. COIL SPECIFICAIONS DC VERSION DAA Nominal Coil Operating range Resistance Consumption voltage code I at N N min max R V V V Ω ma , ,700.3 ACCESSORIES AC VERSION DAA Nominal Coil Operating range Resistance Consumption voltage code I at N (50Hz) N min max R V V V Ω ma , , ,400 Sheet of marker tags (4 tags): 9x7mm

168 6 Series - Step Relays 0 A - Screw terminal connections - AC coil - Panel mount ,04,06, Single phase switch NO - Double phase switch NO - NC + NO Ø Ø Ø Contact specifications Number of contacts NO NO NC + NO Rated current/max. peak current A 0/0 0/0 0/0 Rated voltage/max. switching voltage V AC 50/400 50/400 50/400 Rated load in AC,500,500,500 Rated load in AC5 (30 C) Nominal lamp rating: incandescent (30V) W compensated fluorescent (30V) W uncompensated fluorescent (30V) W halogen (30V) W Minimum switching load mw(v/ma),000 (0/0),000 (0/0),000 (0/0) Standard contact material AgNi AgNi AgNi Coil specifications Nominal voltage V AC (50Hz) V DC Rated power AC/DC (50Hz)/W 4.5/ 4.5/ 4.5/ Operating range AC (50Hz) (0.8.) N (0.8.) N (0.8.) N DC echnical data Mechanical life cycles Electrical life at rated load in AC cycles Minimum/Maximum impulse duration Insulation between coil and contacts (./50µs) kv 0.s/h (according to EN 60669) 4 0.s/h (according to EN 60669) 4 0.s/h (according to EN 60669) 4 Ambient temperature range C Protection category IP 0 IP 0 IP 0 Approvals: (according to type) GOS 64

169 6 Series - Step Relays 0 A ORDERING INFORMAION Example: a 6 series screw terminal mount relay with double phase switch NO - 0 A contacts, with coil rated at V AC Series ype 0 = Screw terminal No. of poles = Single phase switch NO = Double phase switch NO 3 = Double phase switch NO + NC 4 = 4 sequence double phase switch NO 6 = 3 sequence double phase switch NO 8 = 4 sequence double phase switch NO Coil voltage see coil specifications Coil version 8 = AC (50 Hz) ECHNICAL DAA INSLAION DIELECRIC SRENGH - between supply and contacts V AC 3,500 - between open contacts V AC,000 - between adjacent contacts V AC,000 OHER DAA 6.0, 6.03, , 6.04, 6.06 POWER LOS O HE ENVIRONMEN - with rated current W MAX WIRE SIZE solid cable stranded cable solid cable stranded cable mm x4 / x.5 x.5 / x.5 x4 / x.5 x.5 / x.5 AWG x / x4 x4 / x4 x / x4 x4 / x4 SCREW ORQE Nm COIL SPECIFICAIONS AC VERSION DAA Nominal Coil Operating range Resistance Consumption voltage code I at N (50Hz) N min max R V V V ma , ,50 0 YPE Number of steps 4 SEQENCES

170 6 Series - Step Relays 0 A WIRING DIAGRAMS L N 3 4 ACCESSORIES -4 V DC CONROL APPLICAIONS V AC DC N = 4 V DC ype: NOMINAL VOLAGE: V DC MAX EMPERARE: + 40 C OPERAING RANGE: (0.9.) N ype: NOMINAL VOLAGE: 4 V DC MAX EMPERARE: + 40 C OPERAING RANGE: (0.9.) N Example of wiring for 4 V DC control application. MODLE FOR ILLMINAED PSH-BONS V DC Ø Ø 0.8 ype Sealed version, 7.5 cm insulated and flexible terminals. Example of wiring diagram of type his module is necessary if using up to a maximum of 5 illuminated pushbuttons (.5 ma max, 30 V AC) in the switching input circuit. It must be connected in parallel to the coil of the relay (see diagram).

171 7 Series - Step Relays 0 A - Screw terminal connections - AC coil - Panel mount /06 - Single phase switch NO - Double phase switch / 4 // Ø Ø 3..5 Contact specifications Number of contacts Rated current/max. peak current A Rated voltage/max. switching voltage V AC Rated load in AC Rated load in AC5 (30 C) Nominal lamp rating: incandescence W compensated fluorescent W uncompensated fluorescent W halogens W Minimum switching current ma Standard contact material Coil specifications Nominal voltage V AC (50/60Hz) V DC Rated power AC/DC (50Hz)/W Operating range AC DC echnical data Mechanical life cycles Electrical life at rated load in AC cycles Minimum/Maximum impulse duration Insulation between coil and contacts (./50µs) kv Ambient temperature range C Protection category Approvals: (according to type) 0/0 0/0 30/30,00, AgNi / (0.8.) N s/h (according to EN 60669) IP 0 GOS 0/0 0/0 30/30,00, AgNi / (0.8.) N s/h (according to EN 60669) IP

Relays, imers, Interface Modules, Sockets and Accessories. 003-004 Catalogue he power EL: in 0755-83376489 relays and timers since 954 E-MAIL: E-MAIL: he power in relays ISO 900 ISO 400 Our four factories

More information

40 Series - Miniature P.C.B. Relays A

40 Series - Miniature P.C.B. Relays A ..4..4..4 40 Series - Miniature P.C.B. Relays 8-0 - 6 A - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./0 µs) between coil and contacts - Ambient

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16

More information

38 Series - Relay Interface Modules A

38 Series - Relay Interface Modules A Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay

More information

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket

More information

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi 34 Series - Slim electromechanical PCB relays 6 A Features 34.51 Ultra-slim 1 Pole - 6 A relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw or screwless sockets 1 Pole

More information

38 Series - Relay interface modules A. Features /

38 Series - Relay interface modules A. Features / Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

The power in relays and timers since Catalogue

The power in relays and timers since Catalogue The power in relays and timers since 1954 2012 Catalogue PCB relays Industrial relays Relay interface modules Sockets and accessories Timers Monitoring relays Energy meters Surge protection devices Industrial

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

48 Series - Relay interface modules A. Features

48 Series - Relay interface modules A. Features Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive

More information

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN

More information

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5) 46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance

More information

62 Series - Power relays 16 A. Features / /

62 Series - Power relays 16 A. Features / / 6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Low profile PCB relays 8-12 - 16 41 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 (3.5 mm pin pitch) 41.52-2 Pole 8 (5 mm pin pitch) 41.61-1 Pole 16 (5 mm pin pitch) PCB mount - direct or

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16 A (5 mm pin pitch) PCB mount - direct

More information

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4 58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals

More information

Relay interface modules A

Relay interface modules A 4C SЕRIES Relay interface modules 8-10 - 16 A Escalators Road / tunnel lighting Hoists and cranes Carousel warehouses Control panels Panels for electrical distribution FINDER reserves the right to alter

More information

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

2 or 4 pole changeover contact Plug-in/Faston 187

2 or 4 pole changeover contact Plug-in/Faston 187 56 Miniature power relays 56 Plug-in - Power relay, & 4 pole Flange mount option - (Faston 87, 4.8 x 0.5 mm termination) C coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross)

More information

83 Series - Modular timers 16 A. Features

83 Series - Modular timers 16 A. Features Features 83 Series - Modular timers 16 A 83.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 83.11 - delay, multi-voltage 22.5 mm wide Six time scales from 0.1s to 20h High

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay 62 Series - Power relays 16 62 SERIES Features 62.22 / 62.23 62.22-0300 / 62.23-0300 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced

More information

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view 66 Series - Power relays 30 A Features 66.22 66.82 2 Pole Changeover (DPDT) 30 A Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil

More information

62.22 Copper side view

62.22 Copper side view 62 Power relays 16 62 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced insulation between coil and contacts according to EN 60335-1,

More information

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1 Features 7S.12...5110 7S.14...0220/0310 7S.16..0420 Relay module with forcibly guided contacts 7S.12 with 2 pole (1NO + 1 NC) 7S.14 with 4 pole (2 NO + 2 NC and 3 NO + 1 NC) 7S.16 with 6 pole (4 NO + 2

More information

Multi-voltage Multi-function. Wiring diagram (without control signal)

Multi-voltage Multi-function. Wiring diagram (without control signal) 80 Modular timers 16 A 80 Multi-function and mono-function timer range 80.01T - Multi-function & multi-voltage 80.11T - On-delay, multi-voltage Complies with EN 45545-2:2013 (protection against fire of

More information

83 SERIES. 83 Series - Modular timers A. Features

83 SERIES. 83 Series - Modular timers A. Features Features 83 Series - Modular timers 12-16 A 83.01 83.02 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous

More information

Multi-function 11 pin Plug-in for use with 90 series sockets

Multi-function 11 pin Plug-in for use with 90 series sockets 88 eries - lug-in timers 5-8 A Features 88.02 88.12 Multi-voltage and multi-function timer range Front panel or socket mount 8-11 pin plug-in version available ime scales from 0.05s to 100h 1 delayed contact

More information

Modular step relays 16 A

Modular step relays 16 A Automation for blinds, grilles and shutters Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control Living room light control SЕRIES FINDER reserves the right to alter characteristics

More information

Modular timers A

Modular timers A Modular timers 1-6 - 8-16 A Building automation Elevators and lifts 80 SЕRIES Automation for blinds, grilles and shutters oists and cranes Panels for electrical distribution Door and gate openers FINDER

More information

87 Series - Modular timers 5-8 A. Features

87 Series - Modular timers 5-8 A. Features 87 eries - Modular timers 5-8 A Features 87.01 87.02 Mono-function and multi-function timer range mm wide 87.01-1 Pole - Multi-function and multi-voltage 87.02-2 Pole - Multi-function and multi-voltage,

More information

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection 65 Power relays 20-30 65 20 Power relays 1 NO + 1 NC (SPST-NO + SPST-NC) 65.31 Flange mount Faston 250 connections 65.61 PCB mount C coils & DC coils Cadmium Free option available 65.31 65.61 20 rated

More information

Multi-function 11 pin Plug-in for use with 90 series sockets

Multi-function 11 pin Plug-in for use with 90 series sockets 88 88 Multi-voltage and multi-function timer range Front panel or socket mount 8 and 11 pin plug-in versions available Time scales from 0.05 s to 100 h 1 delayed contact +1 instantaneous contact version

More information

A rated contacts PCB mount - bifurcated terminals. Copper side view

A rated contacts PCB mount - bifurcated terminals. Copper side view 66 Power relays 30 66 2 Pole Changeover (DPDT) 30 Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil and contacts according to EN 60335-1;

More information

Relè di potenza 30 A SЕRIES. Power. generators. Industrial washing machines. Burners, boilers and furnaces. Industrial furnaces and ovens

Relè di potenza 30 A SЕRIES. Power. generators. Industrial washing machines. Burners, boilers and furnaces. Industrial furnaces and ovens 66 SЕRIES Relè di potenza 30 Power generators Industrial washing machines Burners, boilers and furnaces Industrial furnaces and ovens ir conditioners Hoists and cranes Back-up generators Industrial motors

More information

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control Living room light control SЕRIES FINDER reserves the right to alter characteristics at any time without notice. FINDER

More information

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal 83 Modular timers 12-16 A 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous options), external time setting

More information

13 Series - Electronic step/monostable & call/reset relays 8-16 A. Features

13 Series - Electronic step/monostable & call/reset relays 8-16 A. Features 13 Series - Electronic step/monostable & call/reset relays 8-16 A Features 13.01 13.12 13.01 - Quiet operating electronic step/ monostable relay 1 Pole output contact 13.12 - Call & Reset Relay 2 Pole

More information

46 SERIES. Fast, Reliable and Secure Connections. Miniature industrial relays. The power in relays and timers since 1954

46 SERIES. Fast, Reliable and Secure Connections. Miniature industrial relays. The power in relays and timers since 1954 SERIES Fast, Reliable and Secure Connections Miniature industrial relays The power in relays and timers since 9 Series - Miniature industrial relays, - A Features & Pole relay range. - Pole A. - Pole A

More information

13 Series - Electronic step relays A. Features SERIES

13 Series - Electronic step relays A. Features SERIES Series - Electronic step relays 10-16 A SERIES Features.81.91.81 - Electronic step relay - Rail mount - 1 Pole.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10

More information

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi Features Special relay for alternating loads, for applications with pumps, compressors, air conditioning or refrigeration units 2 independent NO output, 12 A 4 functions 2 independent control signals,

More information

13 Series - Electronic step relays A. Features Residential applications

13 Series - Electronic step relays A. Features Residential applications 13 13 Series - Electronic step relays 10-16 A Features 13.81 13.91 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed

More information

13 SERIES. Electronic step relays A

13 SERIES. Electronic step relays A 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

CARREL-ELECTRADE LTD not just products... solutions!

CARREL-ELECTRADE LTD not just products... solutions! FINDER S RANGE OF DIN MOUNTED TIMERS 80 & 83 SERIES MULTI-VOLTAGE & MULTI-FUNCTION CARREL-ELECTRADE LTD not just products... solutions! Proudly 100% New Zealand owned and operated Auckland 661 Great South

More information

Electronic step, call/reset and monostable relays

Electronic step, call/reset and monostable relays Electronic step, call/reset and monostable relays W/C Call and reset switches for bathrooms Bathrooms lighting control Bedroom light control Living room light control Office lighting control SЕRIES FINDER

More information

SMARTimer, digital timer 16 A

SMARTimer, digital timer 16 A SMARTimer, digital timer 16 A Timers and lighting controls Automatic car-washes 84 SЕRIES Labelling machines Punches, cleaners, planers and sanders Industrial furnaces and ovens Discotheques, swimming

More information

Miniature Power Relay MSR

Miniature Power Relay MSR V23061 PCB relay for DC voltage, neutral, monostable Features Used as a switching element for electrical separation between low-power control circuits and power load circuits With 8 mm clearance and creepage

More information

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz) 77 Modular Solid State Relay 5 A 77 5 A modular SSR, 1 NO AC output 17.5 mm housing 60 to 240 V AC output (with back to back SCR) 5 kv (1.2/50 µs) insulation between and Output Zero-crossing and random

More information

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays Series - Modular Solid State Relay 5 A 77 Features 77.01.x.xxx.8050 77.01.x.xxx.8051 5 A modular SSR, 1 NO output 17.5 mm housing 60 to 240 V AC output (with back to back SCR) 5 kv (1.2/50 μs) insulation

More information

SIGMA Terminal components

SIGMA Terminal components SIGMA Terminal components Optocouplers Content Terminal components Description, Certifications, Authorizations... 151 Ordering details R1000 / R2000 / R 1500... 152 Ordering details - Series RT, PT, MT...

More information

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable Features 72.01 72.11 Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator Reinforced insulation (6 kv - 1.2/50

More information

46.61 Series, SPDT 16A. Part Number Price Coil Voltage

46.61 Series, SPDT 16A. Part Number Price Coil Voltage www.factorymation.com/relays 85 Miniature Ice Cube Relays Mechanical flag indicator shows contact status Momentary / Lockable test button AgNi contacts (Cadmium free) Operating temperature: 40 to 58 F

More information

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable Features Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions LED indicator Reinforced insulation (6 kv - 1.2/50 µs) between:

More information

relais A mark Relay modules

relais A mark Relay modules Relay modules relais Introduction to relay technology Modular DIN rail mounted relays Plug-in DIN rail mounted relays Multiple chassis mounted relays Timer relays The relay modules offer features such

More information

Model Number Structure

Model Number Structure General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long

More information

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations

More information

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A PCB Relay G6RL Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) IEC 60947-5-1, AC-15, DC13 Clearance and creepage distance: 10

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Classification Enclosure rating Contact form Contact material

Classification Enclosure rating Contact form Contact material PCB Relay Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm.

More information

OMRON MK-I / -S RELAY

OMRON MK-I / -S RELAY Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks

More information

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts) IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact

More information

RELOG. All-or-nothing Relay

RELOG. All-or-nothing Relay RELOG All-or-nothing Relay Table of Content Page RELOG a system with contact components used in control engineering 3 Survey of the 'All-or-nothing relays' device program included in the RELOG system 3

More information

Interface relays and optocouplers Product group picture

Interface relays and optocouplers Product group picture Interface relays and optocouplers Product group picture /1 ABB Catalog Electronic Products and Relays 2013/2014 2CDC 1 004 C0209 Interface relays and optocouplers Table of contents Interface Relays and

More information

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A PCB Relay Low-profile power relay with maximum switching of 8 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm. RoHS

More information

1a/1c/2a/2c/5A/10A power relays for power supply

1a/1c/2a/2c/5A/10A power relays for power supply a/c/2a/2c/a/a power relays for power supply JW RELAYS RoHS compliant Protective construction: Flux-resistant type/ ORDERING INFORMATION JW Contact arrangement : Form C a: Form A 2: 2 Form C 2a: 2 Form

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Pluggable interface relays CR-U Universal relays

Pluggable interface relays CR-U Universal relays Data sheet Pluggable interface relays CR-U Universal relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

ET M3792_a. DC 6, 12, 15, 20, 24 V AC 12, 24, 42, 230 V Voltage range U N

ET M3792_a. DC 6, 12, 15, 20, 24 V AC 12, 24, 42, 230 V Voltage range U N Control Technique Connecting Module Interface Relay Pluggable HC 09 078 According to DIN EN 18 output contacts with monostable PCB-relay OA 8 Version with bistable PCB-relay OB 9 Contact material with

More information

General-purpose Relay

General-purpose Relay General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different rated control supply voltages U S : DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements

More information

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz) Modular 5 A 5 A modular SSR, 1 NO AC output 17.5 mm housing 60 to 240 V AC output (with back to back SCR) 5 kv (1.2/50 µs) insulation between and Output Zero-crossing and random switch-on versions available

More information

COMPACT PC BOARD POWER RELAY

COMPACT PC BOARD POWER RELAY VDE PACT PC BOARD POWER RELAY JW RELAYS.... Compliance with RoHS Directive FEATURES Miniature package with universal terminal footprint High dielectric withstanding for transient protection:, V surge in

More information

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight

More information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors. Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring

More information

1a/1c/2a/2c/5A/10A power relays for power supply

1a/1c/2a/2c/5A/10A power relays for power supply Automation Controls Catalog VDE a/c/2a/2c/a/a power relays for power supply JW RELAYS RoHS compliant Protective construction: Flux-resistant /Sealed ORDERING INFORMATION Contact arrangement : Form C a:

More information

COMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance

COMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance VDE PACT PC BOARD POWER RELAY JW RELAYS..... FEATURES Miniature package with universal terminal footprint High dielectric withstanding for transient protection:, V surge in µs between coil and contact

More information

G2RL-1A G2RL-1 G2RL-2A G2RL-2

G2RL-1A G2RL-1 G2RL-2A G2RL-2 9 PCB Relay High Capacity, Low Profile Relay Low profile:.7 mm max. in height Cadmium-free contacts ensuring environment-friendly use 0 kv impulse surge withstand Clearance and creepage distance: 0 mm/0

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Song Chuan / Relay Catalog 507

Song Chuan / Relay Catalog 507 07 eatures High rating miniature PCB Relay. AC & DC coil are both available. UL/CUL and VDE approved. 7A 277VAC SPDT. 2A 277VAC DPDT. Low profile.7 and high insulation system class High CTI material &

More information

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6). Power PCB Relay Subminiature 20 L x 9.90 W x 9.90 H mm (0.79 L x 0.39 W x 0.39 H in) Low power consumption (200 mw) Sealed construction permits automatic soldering and cleaning of the PC board High-capacity

More information

CONTA-ELECTRONICS. Relay systems

CONTA-ELECTRONICS. Relay systems CONTA-ELECTRONICS Relay technology continues to play a large role in the reliability of industrial control and automation solutions. Because of their thin design, relay couplers are suitable for use in

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

Index - General technical information

Index - General technical information Index - General technical information FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of

More information

V DC 4 POLE RELAY RC V DC 4 POLE RELAY (RC) V AC 4 POLE RELAY

V DC 4 POLE RELAY RC V DC 4 POLE RELAY (RC) V AC 4 POLE RELAY DT SHEET Plug-in power relays Order code Manufacturer code Description -.. V DC POLE RELY RC -.. V DC POLE RELY (RC) -.. V C POLE RELY Plug-in power relays The enclosed information is believed to be correct,

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Relay modules, Relay sockets, Plug relays

Relay modules, Relay sockets, Plug relays , Relay sockets, Plug relays General information Relay input side (coil) Single relays housed in slim, rail mounting enclosures taking up the minimum of space. Multiple relays (up to 24) in compact rail

More information

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

Subminiature Automotive Relays Type CV20 Monostable

Subminiature Automotive Relays Type CV20 Monostable Subminiature Automotive Relays Type CV20 Subminiature relay Switching capacity 20 A DC coils 6 to 24 VDC 1 change over contact/1 double make contact High resistance to vibration and shock Low power consumption

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

Relay systems. Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC

Relay systems. Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC IRC relay couplers and MFR-IRCP timing relays embody a new strategy for 6.2 mm coupling relays. Our five different relay versions provide

More information

COMPACT PC BOARD POWER RELAY

COMPACT PC BOARD POWER RELAY VDE PACT PC BOARD POWER RELAY JW RELAYS..... RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Miniature package with universal terminal footprint High dielectric withstanding for

More information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -

More information