Siemens Controls SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE W780/W n 1

Size: px
Start display at page:

Download "Siemens Controls SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE W780/W n 1"

Transcription

1 Approvals for SCALANCE W780/W n 1 Approvals for SCALANCE W788C/W786C n 2 SIMATIC NET Industrial Wireless LAN Approvals SCALANCE W n Approvals for SCALANCE W770/W n 3 Approvals for SCALANCE W760/W n 4 Reference Manual Siemens Controls 09/2017 C79000G8976C39206

2 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach NÜRNBERG GERMANY C79000G8976C39206 P 09/2017 Subject to change Copyright Siemens AG All rights reserved

3 Table of contents 1 Approvals for SCALANCE W780/W n EC declaration of conformity ATEX RoHS R&TTE / RED Protection of health and safety EMC Efficient use of the radio spectrum Products General approvals SCALANCE W780/W740 national approvals Approvals for SCALANCE W788C/W786C n EC declaration of conformity ATEX RoHS R&TTE / RED Protection of health and safety Efficient use of the radio spectrum EMC Products General approvals SCALANCE W788C/W786C national approvals Approvals for SCALANCE W770/W n EC declaration of conformity ATEX RoHS R&TTE / RED Protection of health and safety EMC Efficient use of the radio spectrum Products General approvals SCALANCE W774/W734 national approvals SCALANCE W778/W738 national approvals Approvals for SCALANCE W760/W n EC declaration of conformity ATEX RoHS R&TTE / RED Siemens Controls Reference Manual, 09/2017, C79000G8976C

4 Table of contents Protection of health and safety EMC Efficient use of the radio spectrum Products General approvals SCALANCE W760/W720 national approvals Index Reference Manual, 09/2017, C79000G8976C39206

5 Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, stateoftheart industrial security concept. Siemens products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For additional information on industrial security measures that may be implemented, please visit Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. of product versions that are no longer supported, and failure to apply the latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under Siemens Controls Reference Manual, 09/2017, C79000G8976C

6 Approvals for SCALANCE W780/W n 6 Reference Manual, 09/2017, C79000G8976C39206

7 Approvals for SCALANCE W780/W n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Product Article number Article number of the US version Access point SCALANCE W7861 RJ45 6GK57861FC000AA0 6GK57861FC000AB0 Dual access points Article number of the IL version SCALANCE W7862 RJ45 6GK57862FC000AA0 6GK57862FC000AB0 6GK57862FC000AC0 SCALANCE W7862IA RJ45 6GK57862HC000AA0 6GK57862HC000AB0 SCALANCE W7862 SFP 6GK57862FE000AA0 6GK57862FE000AB0 Product Article number Article number of the US version Access points SCALANCE W7881 RJ45 6GK57881FC000AA0 6GK57881FC000AB0 SCALANCE W7881 M12 6GK57881GD000AA0 6GK57881GD000AB0 Dual access points Article number of the IL version SCALANCE W7882 RJ45 6GK57882FC000AA0 6GK57882FC000AB0 6GK57882FC000AC0 SCALANCE W7882 M12 6GK57882GD000AA0 6GK57882GD000AB0 SCALANCE W7882 M12 EEC 6GK57882GD000TA0 6GK57882GD000TB0 Ethernet client modules SCALANCE W71 RJ45 6GK571FC000AA0 6GK571FC000AB0 SCALANCE W71 M12 6GK571GD000AA0 6GK571GD000AB0 Siemens Controls Reference Manual, 09/2017, C79000G8976C

8 Approvals for SCALANCE W780/W n 1.1 EC declaration of conformity Abbreviations used Some approvals apply only to certain devices or series. In such situations, the designations of the products are shortened to avoid having to list all the type designations. The following table shows how the abbreviations relate to the product variants. Product group Designation Product Access points (IP30 und IP65) W788x SCALANCE W7881 M12 SCALANCE W7882 M12 SCALANCE W7882 M12 EEC SCALANCE W7881 RJ45 SCALANCE W7882 RJ45 Access points (IP65) W786x SCALANCE W7861 RJ45 SCALANCE W7862 RJ45 SCALANCE W7862IA RJ45 SCALANCE W7862 SFP SCALANCE W without W786x W7x8 SCALANCE W7881 RJ45 SCALANCE W7881 M12 SCALANCE W7882 RJ45 SCALANCE W7882 M12 SCALANCE W7882 M12 EEC SCALANCE W71 RJ45 SCALANCE W71 M EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support ( 8 Reference Manual, 09/2017, C79000G8976C39206

9 Approvals for SCALANCE W780/W n 1.1 EC declaration of conformity The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until ). 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages (as of ) 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until ). 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages (as of ) 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/ec (until ) and 2014/34/EU (as of ) "Equipment and Protective Devices for in Potentially Explosive Atmospheres" according to the standards listed in the section Products (Page 12): Applied standard: 1 EN A11 Hazardous areas Part 0: Equipment General requirements 2 EN Explosive atmospheres Part 15: Equipment protection by type of protection "n" Siemens Controls Reference Manual, 09/2017, C79000G8976C

10 Approvals for SCALANCE W780/W n 1.1 EC declaration of conformity RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: 3 EN Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances R&TTE / RED Protection of health and safety Article 3 (1) a) protection of health and safety 4 EN A1+A2+A11+A12 Information technology equipment Safety Part 1: General requirements 5 EN Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz) EMC Art. 3 (1) b EMC 6 EN AC Railway applications Electromagnetic compatibility part 32: Railway Vehicles Devices 7 EN AC Railway applications Electromagnetic compatibility part 4: Interference emissions and immunity of signal telecommunications equipment 8 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 1 : Common technical requirements 9 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 17 : 10 Reference Manual, 09/2017, C79000G8976C39206

11 Approvals for SCALANCE W780/W n 1.1 EC declaration of conformity 10 EN 6061 Electromagnetic compatibility (EMC) Part 61: Generic standards Immunity for residential, commercial and lightindustrial environments 11 EN 6062+AC Electromagnetic compatibility (EMC) Part 62: Generic standards Immunity for industrial environments 12 EN 6063+A1+AC Electromagnetic compatibility (EMC) Part 63: Generic standards Emission standard for residential, commercial and lightindustrial environments EN 60+A1 Electromagnetic compatibility (EMC) Part : Generic standards Emission standard for industrial environments Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 14 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) wideband transmission systems data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN Broadband Radio Access Networks (BRAN) 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive. Siemens Controls Reference Manual, 09/2017, C79000G8976C

12 Approvals for SCALANCE W780/W n 1.1 EC declaration of conformity Products CE conformity The standards applying to the product are described in RoHS (Page 10), ATEX (Page 9) and R&TTE / RED (Page 10). Product Standards W7861 RJ45 1, 2, 3, 4, 5, 8, 9, 10, 11, 12,, 14, 15 W7862 RJ45 W7862IA RJ45 W7862 SFP W7881 RJ45 W7882 RJ45 W7881 M12 W7882 M12 W71 RJ45 W71 M12 W7882 M12 EEC 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,, 14, 15 Certification ID The following table shows the product names and the corresponding certification ID: Product Certification ID Article number Article number of the US version Article number of the IL version W7861 RJ45 EAPNW1RJE3 6GK57861FC000AA0 6GK57861FC000AB0 W7862 RJ45 EAPNW2RJE3 6GK57862FC000AA0 6GK57862FC000AB0 6GK57862FC000AC0 W7862IA RJ45 EAPNW2RJI3 6GK57862HC000AA0 6GK57862HC000AB0 W7862 SFP EAPNW2SFPE3 6GK57862FE000AA0 6GK57862FE000AB0 12 Reference Manual, 09/2017, C79000G8976C39206

13 Approvals for SCALANCE W780/W n 1.2 General approvals Product Certification ID Article number Article number of the US version Article number of the IL version W7881 RJ45 RAPNW1RJE3 6GK57881FC000AA0 6GK57881FC000AB0 W7882 RJ45 RAPNW2RJE3 6GK57882FC000AA0 6GK57882FC000AB0 6GK57882FC000AC0 W7881 M12 RAPNW1M12E3 6GK57881GD000AA0 6GK57881GD000AB0 W7882 M12 RAPNW2M12E3 6GK57882GD000AA0 6GK57882GD000AB0 W7882 M12 EEC RAPNW2M12E3 6GK57882GD000TA0 6GK57882GD000TB0 W71 RJ45 RAPNW1RJE3 6GK571FC000AA0 6GK571FC000AB0 W71 M12 RAPNW1M12E3 6GK571GD000AA0 6GK571GD000AB0 1.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support ( Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for in Potentially Explosive Atmospheres. and as of the EC directive 2014/34/EU. ATEX classification: II 3 G Ex na IIC T4 Gc Siemens Controls Reference Manual, 09/2017, C79000G8976C39206

14 Approvals for SCALANCE W780/W n 1.2 General approvals KEMA 07ATEX0145 X The products meet the requirements of the following standards: EN (electrical apparatus for potentially explosive atmospheres; Type of protection "n") EN (Explosive atmospheres Part 0: Equipment General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex na IIC T4 Gc DEK X The products meet the requirements of the following standards: IEC (Explosive atmospheres Part 15: Equipment protection by type of protection "n") IEC (Explosive atmospheres Part 0: Equipment General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. FM The product meets the requirements of the standards: Factory Mutual Approval Standard Class Number 11 FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 culus Approval for Information Technology Equipment culus Listed I. T. E. Underwriters Laboratories Inc. complying with UL (Information Technology Equipment) CSA C22.2 No Report no. E1153 Note Only devices of the SCALANCE W786x series have this approval. 14 Reference Manual, 09/2017, C79000G8976C39206

15 Approvals for SCALANCE W780/W n 1.2 General approvals culus Approval Hazardous Location culus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with UL (Information Technology Equipment) ANSI/ISA CSA C22.2 No. 2M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E2400 FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE b or g operation of this product in the USA is firmwarelimited to channels 1 through 11. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Siemens Controls Reference Manual, 09/2017, C79000G8976C

16 Approvals for SCALANCE W780/W n 1.2 General approvals Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as colocated antennas transmitting the same information) is expressly forbidden. Notice For use of DFS channels of the RCoax Cable Antenna 6XV187D is not permitted in channels which require dynamic frequency selection (DFS). Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (centertocenter) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, ( When you open this link, you get the following choices: "Search" opens a window with TDWR locations and frequencies. "r Signup" allows you to register as user of the database. After registering you can Logon and register your WLAN location. Please fill in all required information. For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB D01. Note for USA, Canada, Columbia, Ecuador, Peru, Puerto Rico, Bahamas, Thailand and Uruguay When operating the SCALANCE W700 with DFS (Dynamic Frequency Selection), the IWLAN RCoax Cable 5 GHz (article number 6XV187D) may not be used in the countries listed above. 16 Reference Manual, 09/2017, C79000G8976C39206

17 Approvals for SCALANCE W780/W n 1.2 General approvals NEMA TS2 The product meets the requirements of the standard NEMA TS2 (Traffic Controller Assemblies with NTCIP Requirements) Product Article number Article number of the US version SCALANCE W7882 M12 EEC 6GK57882GD000TA0 6GK57882GD000TB0 RSS247 of Industry Canada This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the respective Operating Instructions with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band MHz is only for indoor usage to reduce potential for harmful interference to cochannel mobile satellite systems. rs should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of MHz and MHz and these radars could cause interference and/or damage to LELAN devices. This equipment complies with IC RSS102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Siemens Controls Reference Manual, 09/2017, C79000G8976C

18 Approvals for SCALANCE W780/W n 1.2 General approvals Approvals in Argentina Devices of the SCALANCE W786x series are approved in Argentina under the following certification numbers: Certification ID Certification number EAPNW1RJE3 CNC: C11549 EAPNW2RJE3 CNC: C115 EAPNW2RJI3 CNC: C115 EAPNW2SFPE3 CNC: C11547 Devices of the SCALANCE W788x series are approved in Argentina under the following certification numbers: Certification ID Certification number RAPNW1RJE3 CNC: C11541 RAPNW2RJE3 CNC: C11502 RAPNW1M12E3 CNC: C11546 RAPNW2M12E3 CNC: C115 Approval in Brazil From the SCALANCE W786x series, the following devices are approved for Brazil: Product Article number EAPN number W7861 RJ45 6GK5 7861FC000AA0 EAPNW1RJE3 W7862 RJ45 6GK5 7862FC000AA0 EAPNW2RJE3 W786C2 RJ45 6GK5 7862FC001AA0 EAPNW2RJE3 W7862IA RJ45 6GK5 7862HC000AA0 EAPNW2RJI3 W786C2IA RJ45 6GK5 7862HC001AA0 EAPNW2RJI3 W7862 SFP 6GK5 7862FE000AA0 EAPNW2SFPE3 The listed devices are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. 18 Reference Manual, 09/2017, C79000G8976C39206

19 Approvals for SCALANCE W780/W n 1.2 General approvals From the SCALANCE W7x8 series, the following devices are approved for Brazil: Product Article number RAPN number W7881 RJ45 6GK 57881FC000AA0 RAPNW1RJE3 W7882 RJ45 6GK5 7882FC000AA0 RAPNW2RJE3 W7881 M12 6GK5 7881GD000AA0 RAPNW1M12E3 W7882 M12 6GK5 7882GD000AA0 RAPNW2M12E3 W7882 M12 EEC 6GK5 7882GD000TA0 RAPNW2M12E3 W71 RJ45 6GK5 71FC000AA0 RAPNW1RJE3 W71 M12 6GK5 71GD000AA0 RAPNW1M12E3 W788C2 RJ45 6GK 57882FC001AA0 RAPNW2RJE3 W788C2 M12 6GK5 7882GD001AA0 RAPNW2M12E3 W788C2 M12 EEC 6GK57882GD001TA0 RAPNW2M12E3 The listed devices are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. KCC Statement (Republic of Korea) 사용자안내문 ( 제 5 조제 1 항제 1 호관련 ) 기종별 A 급기기급기기 ( 업무용방송통신기기 ) 사용자안내문 이기기는업무용 (A 급 ) 으로전자파적합등록을한 (A 급 ) 으로전자파적합등록을한 기기이오니판매자또는사용자는이점을 주의하시기바라며, 가정외의지역에서사용하는 것을목적으로합니다. " 당해무선설비는전파혼신가능성이있으므로인명안전과관련된서비스는할수없음 " Approval for Mexico The WLAN modules included in the devices have the following certification number: RCPSIMP Siemens Controls Reference Manual, 09/2017, C79000G8976C

20 Approvals for SCALANCE W780/W n 1.2 General approvals Approval for Oman Devices of the SCALANCE W786x series are approved in Oman under the following certification numbers: OMANTRA R/1773/14 D Devices of the SCALANCE W788x series are approved in Oman under the following certification numbers: OMANTRA R/1772/14 D NCC Warning Statement (Taiwan) Article 12 Without permission, any company, firm or user shall not alter the frequency, increase the power, or change the characteristics and functions of the original design of the certified lower power frequency electric machinery. Article 14 The application of low power frequency electric machineries shall not affect the navigation safety nor interfere a legal communication, if an interference is found, the service will be suspended until improvement is made and the interference no longer exists. Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) Railway approval for the SCALANCE W7882 M12 EEC The SCALANCE W7882 M12 EEC device meets the requirements of the railway standard EN 50155:2007 "Railway Applications Electronic equipment used on rolling stock". 20 Reference Manual, 09/2017, C79000G8976C39206

21 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals 1.3 SCALANCE W780/W740 national approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol ( ) identifies all countries or frequency ranges for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: Column Country Mode CH MHz PWR MaxAntGain Meaning Country IEEE standard and the and / or DFS functionality, where required Channel Frequency Maximum permitted effective isotropic radiated power Maximum permitted antenna gain Permitted use indoors and / or outdoors Siemens Controls Reference Manual, 09/2017, C79000G8976C

22 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor + outdoor 25 mw 0 Indoor + outdoor Egypt (1), (2) 11g 11n 1 mw 0 Indoor + outdoor 22 Reference Manual, 09/2017, C79000G8976C39206

23 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Albania 11g 11n 1 DFS + 2 Angola 11g 11n 1 DFS + 2 Argentina 11g 11n MaxAnt Gain mw 0 Indoor + outdoor mw 0 Indoor + outdoor 50 mw 0 Indoor + outdoor 250 mw 0 Indoor + outdoor 250 mw 0 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

24 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Australia New Zealand g 11n 1 DFS Bahrain 11g 11n 1 DFS Belarus 11g 11n 1 TCP TCP + DFS MaxAnt Gain 250 mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor 2000 mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor 24 Reference Manual, 09/2017, C79000G8976C39206

25 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Brazil 11g 11n Cayman Islands 11g 11n 1 DFS + 2 Chile 11g 11n 1 DFS + DFS MaxAnt Gain 4000 mw 0 Indoor + outdoor 4000 mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor only mw 0 Indoor only mw 0 Indoor only mw 0 Indoor only Siemens Controls Reference Manual, 09/2017, C79000G8976C

26 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals China 11g 11n 1 DFS Ivory Coast 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor + outdoor 2000 mw 0 Indoor + outdoor mw 0 Indoor + outdoor Guatemala 11g 11n 1 mw 0 Indoor + outdoor 2 10 DFS mw 0 Indoor + outdoor mw 0 Indoor + outdoor Reference Manual, 09/2017, C79000G8976C39206

27 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals 2 MaxAnt Gain Siemens Controls Reference Manual, 09/2017, C79000G8976C Hong Kong 11g 11n 1 DFS + 2 India 11g 11n 1 DFS Israel (2) 11g 11n 1 DFS mw 0 Indoor + outdoor mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 0 Indoor + outdoor

28 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals MaxAnt Gain Indonesia 11g 11n 1 mw 0 Indoor + outdoor Japan 11g 11n 1 DFS + 11a Kazakhstan 11g 11n 1 DFS + 2 Qatar 11g 11n mw 0 Indoor + outdoor mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor only mw 0 Indoor only 28 Reference Manual, 09/2017, C79000G8976C39206

29 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Korea 11g 11n Kuwait 11g 11n 1 DFS + Macau 11g 11n MaxAnt Gain mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 6 Indoor + outdoor mw 0 Indoor + outdoor Madagascar 11g 11n 1 DFS Malaysia 11g 11n 1 40 mw 0 Indoor only 0 mw 0 Indoor only 0 mw 0 Indoor only 400 mw 0 Indoor only 200 mw 0 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

30 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Morocco (only with SCALANCE W7862IA RJ 45) DFS g 11n 1 DFS + Mexico 11g 11n Mozambique 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor only 500 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 0 Indoor + outdoor 30 Reference Manual, 09/2017, C79000G8976C39206

31 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Oman 11g 11n 1 DFS + MaxAnt Gain 40 Siemens Controls Reference Manual, 09/2017, C79000G8976C Pakistan 11g 11n Russia 11g 11n 1 DFS Saudi Arabia 11g 11n mw 0 Indoor only mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor

32 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals DFS + 2 Serbia 11g 11n 1 DFS + 2 South Africa 11g 11n 1 Singapore Philippines DFS g 11n MaxAnt Gain mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor 32 Reference Manual, 09/2017, C79000G8976C39206

33 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals DFS MaxAnt Gain 200 mw 0 Indoor + outdoor Taiwan 11g 11n 1 mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor Thailand 11g 11n 1 11 DFS mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

34 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals 149 Ukraine 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor Uruguay 11g 11n 1 mw 0 Indoor + outdoor 2 10 DFS mw 0 Indoor + outdoor mw 0 Indoor + outdoor Reference Manual, 09/2017, C79000G8976C39206

35 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals Bahamas Ecuador Canada Colombia Peru Puerto Rico Uruguay USA (3) American Samoa (3) Guam (3) Northern Mariana Islands (3) US Virgin Islands (3) MaxAnt Gain 11g 11n 1 mw 0 Indoor + outdoor 2 10 DFS mw 0 Indoor + outdoor mw 0 Indoor + outdoor Venezuela 11g 11n 1 United Arab Emirates DFS g 11n 1 DFS mw 0 Indoor only 4000 mw 0 Indoor + outdoor mw 0 Indoor only Siemens Controls Reference Manual, 09/2017, C79000G8976C

36 Approvals for SCALANCE W780/W n 1.3 SCALANCE W780/W740 national approvals 2 Vietnam 11g 11n 1 DFS (1) Outdoor use only permitted with extra license (2) device of the IL version (3) device of the US version MaxAnt Gain 0 mw 0 Indoor only 0 mw 0 Indoor only mw 0 Indoor + outdoor Reference Manual, 09/2017, C79000G8976C39206

37 Approvals for SCALANCE W788C/W786C n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Product SCALANCE W786C2 RJ45 SCALANCE W786C2IA RJ45 SCALANCE W786C2 SFP Article number 6GK5 7862FC001AA0 6GK5 7862HC001AA0 6GK5 7862FE001AA0 Product SCALANCE W788C2 RJ45 SCALANCE W788C2 M12 SCALANCE W788C2 M12 EEC Article number 6GK5 7882FC001AA0 6GK5 7882GD001AA0 6GK57882GD001TA0 2.1 EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support Siemens Controls Reference Manual, 09/2017, C79000G8976C

38 Approvals for SCALANCE W788C/W786C n 2.1 EC declaration of conformity The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until ). 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages (as of ) 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until ). 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages (as of ) 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/ec (until ) and 2014/34/EU (as of ) "Equipment and Protective Devices for in Potentially Explosive Atmospheres" according to the standards listed in the section Products (Page 41): Applied standard: 1 EN A11 Hazardous areas Part 0: Equipment General requirements 2 EN Explosive atmospheres Part 15: Equipment protection by type of protection "n" 38 Reference Manual, 09/2017, C79000G8976C39206

39 Approvals for SCALANCE W788C/W786C n 2.1 EC declaration of conformity RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: 3 EN Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances R&TTE / RED Protection of health and safety Article 3 (1) a) protection of health and safety 4 EN A1+A2+A11+A12 Information technology equipment Safety Part 1: General requirements 5 EN Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz) Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 14 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) wideband transmission systems data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN Broadband Radio Access Networks (BRAN) 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive Siemens Controls Reference Manual, 09/2017, C79000G8976C

40 Approvals for SCALANCE W788C/W786C n 2.1 EC declaration of conformity EMC Art. 3 (1) b EMC 6 EN AC Railway applications Electromagnetic compatibility part 32: Railway Vehicles Devices 7 EN AC Railway applications Electromagnetic compatibility part 4: Interference emissions and immunity of signal telecommunications equipment 8 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 1 : Common technical requirements 9 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 17 : 10 EN 6061 Electromagnetic compatibility (EMC) Part 61: Generic standards Immunity for residential, commercial and lightindustrial environments 11 EN 6062+AC Electromagnetic compatibility (EMC) Part 62: Generic standards Immunity for industrial environments 12 EN 6063+A1+AC Electromagnetic compatibility (EMC) Part 63: Generic standards Emission standard for residential, commercial and lightindustrial environments EN 60+A1 Electromagnetic compatibility (EMC) Part : Generic standards Emission standard for industrial environments 40 Reference Manual, 09/2017, C79000G8976C39206

41 Approvals for SCALANCE W788C/W786C n 2.1 EC declaration of conformity Products CE conformity The standards applying to the product are described in RoHS (Page 39), ATEX (Page 38) and R&TTE / RED (Page 39). Product Standards W786C2 RJ45 1, 2, 3, 4, 5, 8, 9, 10, 11, 12,, 14, 15, 16 W786C2IA RJ45 W7862 SFP W788C2 RJ45 W788C2 M12 W788C2 M12 EEC 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,, 14, 15, 16 Certification ID The following tables show the product names and the corresponding certification ID: Product Certification ID Article number W786C2 RJ45 EAPNW2RJE3 6GK57862FC001AA0 W786C2IA RJ45 EAPNW2RJI3 6GK57862HC001AA0 W7862 SFP EAPNW2SFPE3 6GK57862FE001AA0 Product Certification ID Article number W788C2 RJ45 RAPNW2RJE3 6GK57882FC001AA0 W788C2 M12 RAPNW2M12E3 6GK57882GD001AA0 W788C2 M12 EEC RAPNW2M12E3 6GK57882GD001TA0 Siemens Controls Reference Manual, 09/2017, C79000G8976C

42 Approvals for SCALANCE W788C/W786C n 2.2 General approvals 2.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support ( Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for in Potentially Explosive Atmospheres. and as of the EC directive 2014/34/EU. ATEX classification: II 3 G Ex na IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: EN (electrical apparatus for potentially explosive atmospheres; Type of protection "n") EN (Explosive atmospheres Part 0: Equipment General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex na IIC T4 Gc DEK X The products meet the requirements of the following standards: IEC (Explosive atmospheres Part 15: Equipment protection by type of protection "n") IEC (Explosive atmospheres Part 0: Equipment General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. 42 Reference Manual, 09/2017, C79000G8976C39206

43 Approvals for SCALANCE W788C/W786C n 2.2 General approvals FM The product meets the requirements of the standards: Factory Mutual Approval Standard Class Number 11 FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 culus Approval Hazardous Location culus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with UL (Information Technology Equipment) ANSI/ISA CSA C22.2 No. 2M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E2400 FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE b or g operation of this product in the USA is firmwarelimited to channels 1 through 11. Siemens Controls Reference Manual, 09/2017, C79000G8976C

44 Approvals for SCALANCE W788C/W786C n 2.2 General approvals This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as colocated antennas transmitting the same information) is expressly forbidden. Notice For use of DFS channels of the RCoax Cable Antenna 6XV187D is not permitted in channels which require dynamic frequency selection (DFS). Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (centertocenter) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, When you open this link, you get the following choices: "Search" opens a window with TDWR locations and frequencies. "r Signup" allows you to register as user of the database. After registering you can Logon and register your WLAN location. Please fill in all required information. 44 Reference Manual, 09/2017, C79000G8976C39206

45 Approvals for SCALANCE W788C/W786C n 2.2 General approvals For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB D01. Note for USA, Canada, Columbia, Ecuador, Peru, Puerto Rico, Bahamas, Thailand and Uruguay When operating the SCALANCE W700 with DFS (Dynamic Frequency Selection), the IWLAN RCoax Cable 5 GHz (article number 6XV187D) may not be used in the countries listed above. NEMA TS2 The product meets the requirements of the standard NEMA TS2 (Traffic Controller Assemblies with NTCIP Requirements) Product SCALANCE W788C2 M12 EEC Article number 6GK57882GD001TA0 RSS247 of Industry Canada This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the respective Operating Instructions with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band MHz is only for indoor usage to reduce potential for harmful interference to cochannel mobile satellite systems. rs should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of MHz and MHz and these radars could cause interference and/or damage to LELAN devices. This equipment complies with IC RSS102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) Siemens Controls Reference Manual, 09/2017, C79000G8976C

46 Approvals for SCALANCE W788C/W786C n 2.2 General approvals l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Approvals in Argentina Devices of the SCALANCE W786x series are approved in Argentina under the following certification numbers: Certification ID Certification number EAPNW1RJE3 CNC: C11549 EAPNW2RJE3 CNC: C115 EAPNW2RJI3 CNC: C115 EAPNW2SFPE3 CNC: C11547 Devices of the SCALANCE W788x series are approved in Argentina under the following certification numbers: Certification ID Certification number RAPNW1RJE3 CNC: C11541 RAPNW2RJE3 CNC: C11502 RAPNW1M12E3 CNC: C11546 RAPNW2M12E3 CNC: C115 Approval in Brazil From the SCALANCE W786x series, the following devices are approved for Brazil: Product Article number EAPN number W7861 RJ45 6GK5 7861FC000AA0 EAPNW1RJE3 W7862 RJ45 6GK5 7862FC000AA0 EAPNW2RJE3 W786C2 RJ45 6GK5 7862FC001AA0 EAPNW2RJE3 W7862IA RJ45 6GK5 7862HC000AA0 EAPNW2RJI3 W786C2IA RJ45 6GK5 7862HC001AA0 EAPNW2RJI3 W7862 SFP 6GK5 7862FE000AA0 EAPNW2SFPE3 The listed devices are approved in Brazil under the following certification numbers: 46 Reference Manual, 09/2017, C79000G8976C39206

47 Approvals for SCALANCE W788C/W786C n 2.2 General approvals Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. From the SCALANCE W7x8 series, the following devices are approved for Brazil: Product Article number RAPN number W7881 RJ45 6GK 57881FC000AA0 RAPNW1RJE3 W7882 RJ45 6GK5 7882FC000AA0 RAPNW2RJE3 W7881 M12 6GK5 7881GD000AA0 RAPNW1M12E3 W7882 M12 6GK5 7882GD000AA0 RAPNW2M12E3 W7882 M12 EEC 6GK5 7882GD000TA0 RAPNW2M12E3 W71 RJ45 6GK5 71FC000AA0 RAPNW1RJE3 W71 M12 6GK5 71GD000AA0 RAPNW1M12E3 W788C2 RJ45 6GK 57882FC001AA0 RAPNW2RJE3 W788C2 M12 6GK5 7882GD001AA0 RAPNW2M12E3 W788C2 M12 EEC 6GK57882GD001TA0 RAPNW2M12E3 The listed devices are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Approval for Mexico The WLAN modules included in the devices have the following certification number: RCPSIMP Approval for Oman Devices of the SCALANCE W786x series are approved in Oman under the following certification numbers: OMANTRA R/1773/14 D Siemens Controls Reference Manual, 09/2017, C79000G8976C

48 Approvals for SCALANCE W788C/W786C n 2.2 General approvals Devices of the SCALANCE W788x series are approved in Oman under the following certification numbers: OMANTRA R/1772/14 D Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) Railway approval for the SCALANCE W788C2 M12 EEC The SCALANCE W7882 M12 EEC device meets the requirements of the railway standard EN 50155:2007 "Railway Applications Electronic equipment used on rolling stock". Reference Manual, 09/2017, C79000G8976C39206

49 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals 2.3 SCALANCE W788C/W786C national approvals The national approval of the controllerbased access points depends on the controller on which they are operated. The controllers are available in the following countryspecific versions: Version for the USA and Canada (NAM) Article number 6GK57110XC001AB0 These countries are indicated in the table (NAM). Version for Japan Article number 6GK57110XC001AD0 Version for countries outside Japan and NAM Article number 6GK57110XC001AA0 The diamond symbol ( ) identifies all countries or frequency ranges for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: Column Country Mode CH MHz PWR Meaning Country IEEE standard and the and / or DFS functionality, where required Channel Frequency Maximum permitted effective isotropic radiated power Permitted use indoors and / or outdoors Siemens Controls Reference Manual, 09/2017, C79000G8976C

50 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals Andorra Belgium Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Serbia Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n 1 11h 11n DFS mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor Egypt 11g 11n 1 mw Indoor + outdoor 200 mw Indoor only 50 Reference Manual, 09/2017, C79000G8976C39206

51 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals Angola 11g 11n 1 11h 11n DFS + Siemens Controls Reference Manual, 09/2017, C79000G8976C Argentina 11g 11n 1 Australia New Zealand g 11n 1 11h 11n DFS mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor 0 mw Indoor + outdoor 50 mw Indoor + outdoor 250 mw Indoor + outdoor 250 mw Indoor + outdoor 250 mw Indoor + outdoor 0 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only

52 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals 149 Bahrain 11g 11n 1 11h 11n DFS Belarus 11g 11n 1 TCP TCP + DFS 2 Brazil 11g 11n Chile 11g 11n mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 2000 mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor 4000 mw Indoor + outdoor 200 mw Indoor only 0 mw Indoor + outdoor 4000 mw Indoor + outdoor mw Indoor only Reference Manual, 09/2017, C79000G8976C39206

53 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals DFS + Siemens Controls Reference Manual, 09/2017, C79000G8976C China 11g 11n Ivory Coast 11g 11n 1 DFS + 2 Guatemala 11g 11n 1 11 DFS mw Indoor only mw Indoor only mw Indoor only mw Indoor + outdoor 2000 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 400 mw Indoor + outdoor 400 mw Indoor + outdoor

54 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals Hong Kong 11g 11n 1 DFS + 2 India 11g 11n 1 11h 11n DFS mw Indoor + outdoor 400 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 200 mw Indoor + outdoor Indonesia 11g 11n 1 mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor 400 mw Indoor + outdoor 54 Reference Manual, 09/2017, C79000G8976C39206

55 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals Japan 11g 11n 1 11a mw Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C h 11n 11a DFS mw Indoor + outdoor mw Note: Qatar 11g 11n Kazakhstan 11g 11n 1 DFS of these channels is no longer allowed in Japan as of mw Indoor only 200 mw Indoor only 200 mw Indoor + outdoor 200 mw Indoor + outdoor mw Indoor only mw Indoor only mw Indoor + outdoor mw Indoor only mw Indoor only mw Indoor + outdoor Colombia (NAM) 11g 11n 1 mw Indoor + outdoor mw Indoor + outdoor

56 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals 149 Korea 11g 11n Kuwait 11g 11n 1 11h 11n DFS + Macau 11g 11n Madagascar 11g 11n 1 DFS mw Indoor only 400 mw Indoor + outdoor 400 mw Indoor + outdoor 400 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor + outdoor 200 mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor 56 Reference Manual, 09/2017, C79000G8976C39206

57 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals 40 Siemens Controls Reference Manual, 09/2017, C79000G8976C Malaysia 11g 11n 1 11h 11n DFS Mexico (NAM) 11g 11n 1 DFS Mozambique 11g 11n 1 11h 11n DFS + 2 Oman 11g 11n mw Indoor + outdoor 200 mw Indoor + outdoor 200 mw Indoor only 0 mw Indoor + outdoor 500 mw Indoor + outdoor 0 mw Indoor + outdoor 0 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only

58 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals DFS Pakistan 11g 11n Russia 11g 11n 1 DFS Saudi Arabia 11g 11n 1 11h 11n DFS mw Indoor only 0 mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor 58 Reference Manual, 09/2017, C79000G8976C39206

59 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals Singapore Philippines 11b 11g 11n 1 DFS South Africa 11g 11n 1 11h 11n DFS mw Indoor + outdoor 200 mw Indoor + outdoor 200 mw Indoor + outdoor 0 mw Indoor + outdoor 0 mw Indoor + outdoor 0 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor Taiwan 11g 11n 1 mw Indoor + outdoor mw Indoor + outdoor mw Indoor + outdoor 400 mw Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

60 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals Thailand 11g 11n 1 DFS Ukraine 11g 11n 1 11h 11n DFS Uruguay 11g a 11a mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor + outdoor 400 mw Indoor + outdoor 400 mw Indoor + outdoor 400 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor + outdoor 200 mw Indoor + outdoor 200 mw Indoor + outdoor 200 mw Indoor + outdoor mw 200 mw Indoor + outdoor 200 mw Indoor only 400 mw Indoor + outdoor 60 Reference Manual, 09/2017, C79000G8976C39206

61 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals 11n 11g Venezuela 11g 11n 1 United Arab Emirates DFS g 11n 1 11h 11n DFS mw 200 mw Indoor + outdoor 200 mw Indoor only 400 mw Indoor + outdoor 0 mw Indoor + outdoor 200 mw Indoor only 0 mw Indoor only 4000 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor only 0 mw Indoor only Siemens Controls Reference Manual, 09/2017, C79000G8976C

62 Approvals for SCALANCE W788C/W786C n 2.3 SCALANCE W788C/W786C national approvals Bahamas (NAM) Ecuador Canada (NAM) Peru Puerto Rico (NAM) USA (NAM) 11g 11n 1 mw Indoor + outdoor DFS mw Indoor + outdoor mw Indoor + outdoor Vietnam 11g 11n 1 11h 11n DFS mw Indoor + outdoor 400 mw Indoor + outdoor 400 mw Indoor + outdoor 400 mw Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only 0 mw Indoor + outdoor 0 mw Indoor + outdoor 400 mw Indoor + outdoor 62 Reference Manual, 09/2017, C79000G8976C39206

63 Approvals for SCALANCE W770/W n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Product Article number Article number of the US version Access points Article number of the IL version SCALANCE W7741 RJ45 6GK57741FX000AA0 6GK57741FX000AB0 6GK57741FX000AC0 SCALANCE W7741 M12 EEC 6GK57741FY000TA0 6GK57741FY000TB0 SCALANCE W7781 M12 6GK57781GY000AA0 6GK57781GY000AB0 SCALANCE W7781 M12 EEC Client module 6GK57781GY000TA0 6GK57781GY000TB0 SCALANCE W7341 RJ45 6GK57341FX000AA0 6GK57341FX000AB0 SCALANCE W7381 M12 6GK57381GY000AA0 6GK57381GY000AB0 3.1 EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support ( Siemens Controls Reference Manual, 09/2017, C79000G8976C

64 Approvals for SCALANCE W770/W n 3.1 EC declaration of conformity The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until ). 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages (as of ) 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until ). 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages (as of ) 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/ec (until ) and 2014/34/EU (as of ) "Equipment and Protective Devices for in Potentially Explosive Atmospheres" according to the standards listed in the section Products (Page 66): Applied standard: 1 EN A11 Hazardous areas Part 0: Equipment General requirements 2 EN Explosive atmospheres Part 15: Equipment protection by type of protection "n" Reference Manual, 09/2017, C79000G8976C39206

65 Approvals for SCALANCE W770/W n 3.1 EC declaration of conformity RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: 3 EN Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances R&TTE / RED Protection of health and safety Article 3 (1) a) protection of health and safety 4 EN A1+A2+A11+A12 Information technology equipment Safety Part 1: General requirements 5 EN Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz) EMC Art. 3 (1) b EMC 6 EN AC Railway applications Electromagnetic compatibility part 32: Railway Vehicles Devices 7 EN AC Railway applications Electromagnetic compatibility part 4: Interference emissions and immunity of signal telecommunications equipment 8 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 1 : Common technical requirements 9 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 17 : Siemens Controls Reference Manual, 09/2017, C79000G8976C

66 Approvals for SCALANCE W770/W n 3.1 EC declaration of conformity 10 EN 6061 Electromagnetic compatibility (EMC) Part 61: Generic standards Immunity for residential, commercial and lightindustrial environments 11 EN 6062+AC Electromagnetic compatibility (EMC) Part 62: Generic standards Immunity for industrial environments 12 EN 6063+A1+AC Electromagnetic compatibility (EMC) Part 63: Generic standards Emission standard for residential, commercial and lightindustrial environments EN 60+A1 Electromagnetic compatibility (EMC) Part : Generic standards Emission standard for industrial environments Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 14 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) wideband transmission systems data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN Broadband Radio Access Networks (BRAN) 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive Products CE conformity The standards that apply to the product are described in ATEX (Page ), RoHS (Page 65) and R&TTE / RED (Page 65) Product Standards W7741 RJ45 1, 2, 3, 4, 5, 8, 9, 10, 11, 12,, 14, 15 W7341 RJ45 W7741 M12 EEC 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,, 14, 15 W7781 M12 3, 4, 5, 8, 9, 10, 11, 12,, 14, 15 W7381 M12 W7741 M12 EEC 3, 4, 5, 8, 9, 11, 12,, 14, Reference Manual, 09/2017, C79000G8976C39206

67 Approvals for SCALANCE W770/W n 3.2 General approvals Certification ID The following table shows the product names and the corresponding certification ID: Product Certification ID Article number Article number of the US version Article number of the IL version W7741 RJ45 MSNW1RJE2 6GK57741FX000AA0 6GK57741FX000AB0 6GK57741FX000AC0 W7741 M12 EEC MSNW1M12E2 6GK57741FY000TA0 6GK57741FY000TB0 W7341 RJ45 MSNW1RJE2 6GK57341FX000AA0 6GK57341FX000AB0 W7781 M12 MSN65W1M12E2 6GK57781GY000AA0 6GK57781GY000AB0 W7381 M12 MSN65W1M12E2 6GK57381GY000AA0 6GK57381GY000AB0 W7781 M12 EEC MSN65W1M12E2 6GK57781GY000TA0 6GK57781GY000TB0 3.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support ( Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for in Potentially Explosive Atmospheres. and as of the EC directive 2014/34/EU. ATEX classification: Siemens Controls Reference Manual, 09/2017, C79000G8976C

68 Approvals for SCALANCE W770/W n 3.2 General approvals II 3 G Ex na IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: EN (electrical apparatus for potentially explosive atmospheres; Type of protection "n") EN (Explosive atmospheres Part 0: Equipment General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex na IIC T4 Gc DEK X The products meet the requirements of the following standards: IEC (Explosive atmospheres Part 15: Equipment protection by type of protection "n") IEC (Explosive atmospheres Part 0: Equipment General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. FM The product meets the requirements of the standards: Factory Mutual Approval Standard Class Number 11 FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 culus Approval Hazardous Location culus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with UL (Information Technology Equipment) ANSI/ISA CSA C22.2 No. 2M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E Reference Manual, 09/2017, C79000G8976C39206

69 Approvals for SCALANCE W770/W n 3.2 General approvals FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE b or g operation of this product in the USA is firmwarelimited to channels 1 through 11. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as colocated antennas transmitting the same information) is expressly forbidden. Siemens Controls Reference Manual, 09/2017, C79000G8976C

70 Approvals for SCALANCE W770/W n 3.2 General approvals Notice For use of DFS channels of the RCoax Cable Antenna 6XV187D is not permitted in channels which require dynamic frequency selection (DFS). Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (centertocenter) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, When you open this link, you get the following choices: "Search" opens a window with TDWR locations and frequencies. "r Signup" allows you to register as user of the database. After registering you can Logon and register your WLAN location. Please fill in all required information. For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB D01. Notice In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. Note for USA, Canada, Columbia, Ecuador, Peru, Puerto Rico, Bahamas, Thailand and Uruguay When operating the SCALANCE W700 with DFS (Dynamic Frequency Selection), the IWLAN RCoax Cable 5 GHz (article number 6XV187D) may not be used in the countries listed above. CSA Information Technology Equipment CSA Certification Mark Canadian Standard Association CSA C22.2 No RSS247 of Industry Canada This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the respective Operating Instructions with the maximum permissible gain and 70 Reference Manual, 09/2017, C79000G8976C39206

71 Approvals for SCALANCE W770/W n 3.2 General approvals required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band MHz is only for indoor usage to reduce potential for harmful interference to cochannel mobile satellite systems. rs should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of MHz and MHz and these radars could cause interference and/or damage to LELAN devices. This equipment complies with IC RSS102 radiation exposure limits set forth for an uncontrolled environment. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Notice In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. Afin de se conformer aux exigences d'exposition RF MIC / FCC / ISED, cet appareil doit être installé pour fournir au moins 20 cm de séparation du corps humain en tout temps. RCM The product meets the requirements of the AS/NZS 20 standard (Class A). Approvals for Argentina Devices of the SCALANCE W760/W720 series are approved in Argentina under the following certification number: Certification ID Certification number ELNW1RJE1 CNC: C172 Siemens Controls Reference Manual, 09/2017, C79000G8976C

72 Approvals for SCALANCE W770/W n 3.2 General approvals Devices of the SCALANCE W770/W730 series are approved in Argentina under the following certification numbers: Certification ID Certification number MSNW1RJE2 CNC: C1 MSNW1M12E2 CNC: C163 Approval for Brazil Devices of the SCALANCE W770/W730 series are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Devices of the SCALANCE W778/W738 series are approved in Brazil under the following certification numbers: Modelo / Model: MSN65W1M12E2 Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. 72 Reference Manual, 09/2017, C79000G8976C39206

73 Approvals for SCALANCE W770/W n 3.2 General approvals KCC Statement (Republic of Korea) 사용자안내문 ( 제 5 조제 1 항제 1 호관련 ) 기종별 A 급기기급기기 ( 업무용방송통신기기 ) 사용자안내문 이기기는업무용 (A 급 ) 으로전자파적합등록을한 (A 급 ) 으로전자파적합등록을한 기기이오니판매자또는사용자는이점을 주의하시기바라며, 가정외의지역에서사용하는 것을목적으로합니다. " 당해무선설비는전파혼신가능성이있으므로인명안전과관련된서비스는할수없음 " Approval for Mexico W770/W730 Devices of the SCALANCE W770/W730 series are approved in Mexico under the following certification numbers: Product W774/W734 RJ45 W774 M12 W778/W738 IFETEL number RCPSIMS RCPSIMS150096A2 RCPSIMS Taiwan: NCC Statement MSN (Chinese) Taiwan: NCC Statement MSN (Chinese) NCC 警語中文如下 : 第十二條 經型式認證合格之低功率射頻電機, 非經許可, 公司 商號或使用者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 ; 經發現有干擾現象時, 應立即停用, 並改善至無干擾時方得繼續使用 前項合法通信, 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波輻射性電機設備之干擾 高增益指向性天線只得應用於固定式點對點系統 ( 此警語僅在有 5G 產品具備外接或替換天線時需加註 ) Siemens Controls Reference Manual, 09/2017, C79000G8976C

74 Approvals for SCALANCE W770/W n 3.2 General approvals Taiwan: NCC Statement (English) Administrative Regulations on Low Power Radio Waves Radiated Devices warning: Article 12 Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radiofrequency devices. Article 14 The low power radiofrequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power radiofrequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices. The operations near the radar system shall not be influenced. The directed antenna with high gain (>6dBi) must apply to the fixed pointtopoint system only. WLAN 2.4G "MPE standard value is 1.0 mw/c Measured value is mw/cm" WLAN 5G "MPE standard value is 1.0 mw/c Measured value is mw/cm" Professional installation Installation and change of RF parameters must be done only by trained professional installers who ensure that the correct power and country settings are selected. Untrained personal shall not have access to the admin password in order to change these parameters. Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) Railway approval for the SCALANCE W7741 M12 EEC and SCALANCE W7781 M12 EEC The SCALANCE W7741 M12 EEC and SCALANCE W7781 M12 EEC devices meet the requirements of the railway standard EN 50155:2007 "Railway Applications Electronic equipment used on rolling stock". 74 Reference Manual, 09/2017, C79000G8976C39206

75 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals 3.3 SCALANCE W774/W734 national approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol ( ) identifies all countries or frequency ranges for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: Column Country Mode CH MHz PWR MaxAntGain Meaning Country IEEE standard and the and / or DFS functionality, where required Channel Frequency Maximum permitted effective isotropic radiated power Maximum permitted antenna gain Permitted use indoors and / or outdoors Siemens Controls Reference Manual, 09/2017, C79000G8976C

76 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n 1 DFS MaxAnt Gain mw 9 Indoor + outdoor 200 mw 9 Indoor only 25 mw 0 Indoor + outdoor Egypt (1), (2) 11g 11n 1 40 mw 9 Indoor + outdoor 200 mw 9 Indoor only 76 Reference Manual, 09/2017, C79000G8976C39206

77 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals DFS + Albania 11g 11n 1 DFS + 2 Angola 11g 11n 1 DFS + 2 Argentina 11g 11n MaxAnt Gain mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 0 mw 9 Indoor + outdoor 50 mw 9 Indoor + outdoor 250 mw 0 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

78 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals Australia New Zealand g 11n 1 DFS Bahrain 11g 11n 1 DFS Belarus 11g 11n 1 TCP TCP + DFS MaxAnt Gain 250 mw 0 Indoor + outdoor 250 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 9 Indoor only 2000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor 78 Reference Manual, 09/2017, C79000G8976C39206

79 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals 2 Brazil 11g 11n Cayman Islands 11g 11n 1 DFS + 2 Chile 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor + outdoor 4000 mw 9 Indoor + outdoor 200 mw 9 Indoor only 4000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor only mw 9 Indoor only mw 0 Indoor only Siemens Controls Reference Manual, 09/2017, C79000G8976C

80 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals DFS 149 China 11g 11n 1 Ecuador (only SCALANCE W7741 RJ45 / W7341 RJ45 ) DFS g 11n 1 11 DFS Ivory Coast 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 2000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 80 Reference Manual, 09/2017, C79000G8976C39206

81 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals 2 MaxAnt Gain Siemens Controls Reference Manual, 09/2017, C79000G8976C Guatemala 11g 11n 1 11 DFS Hong Kong 11g 11n 1 DFS + 2 India 11g 11n mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only

82 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals DFS Indonesia 11g 11n 1 Iran (only SCALANCE W7741 RJ45 / W7341 RJ45 ) g 11n 1 DFS Israel (2) 11g 11n 1 DFS + Japan 11g 11n MaxAnt Gain 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 82 Reference Manual, 09/2017, C79000G8976C39206

83 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals DFS + 11a Kazakhstan 11g 11n 1 DFS + 2 Qatar 11g 11n Korea 11g 11n Kuwait 11g 11n 1 DFS MaxAnt Gain 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 9 Indoor only mw 0 Indoor only 400 mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

84 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals Macau 11g 11n MaxAnt Gain mw 9 Indoor + outdoor mw 6 Indoor + outdoor mw 0 Indoor + outdoor Madagascar (only SCALANCE W7741 RJ45 / W7341 RJ45 ) 11g 11n 1 DFS Malaysia 11g 11n 1 DFS Mexico 11g 11n mw 9 Indoor only 200 mw 9 Indoor only 0 mw 0 Indoor only 0 mw 0 Indoor only 400 mw 0 Indoor only 200 mw 9 Indoor + outdoor 500 mw 9 Indoor + outdoor 200 mw 9 Indoor + outdoor 84 Reference Manual, 09/2017, C79000G8976C39206

85 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals 149 MaxAnt Gain Siemens Controls Reference Manual, 09/2017, C79000G8976C Mozambique 11g 11n 1 Oman (only SCALANCE W7741 RJ45 / W7341 RJ45 ) DFS g 11n 1 DFS Pakistan 11g 11n Russia 11g 11n mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor only 200 mw 9 Indoor only mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 9 Indoor + outdoor

86 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals DFS + 2 Saudi Arabia 11g 11n 1 DFS + 2 Serbia 11g 11n 1 DFS + 2 South Africa 11g 11n MaxAnt Gain mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 86 Reference Manual, 09/2017, C79000G8976C39206

87 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals Singapore Philippines DFS g 11n 1 DFS + MaxAnt Gain Siemens Controls Reference Manual, 09/2017, C79000G8976C Thailand 11g 11n 1 11 DFS mw 9 Indoor + outdoor 200 mw 9 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor

88 Approvals for SCALANCE W770/W n 3.3 SCALANCE W774/W734 national approvals MaxAnt Gain Taiwan 11g 11n 1 mw 9 Indoor + outdoor Bahamas Canada Colombia Peru Puerto Rico Uruguay USA (3) American Samoa (3) Guam (3) Northern Mariana Islands (3) US Virgin Islands (3) mw 9 Indoor + outdoor mw 9 Indoor + outdoor 11g 11n 1 11 DFS Venezuela 11g 11n 1 DFS mw 9 Indoor + outdoor 200 mw 9 Indoor only 0 mw 9 Indoor + outdoor 200 mw 9 Indoor only 0 mw 0 Indoor only 4000 mw 0 Indoor + outdoor 88 Reference Manual, 09/2017, C79000G8976C39206

89 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals United Arab Emirates 11g 11n 1 DFS + 2 Vietnam 11g 11n 1 DFS (1) Outdoor use only permitted with extra license (2) device of the IL version (3) device of the US version MaxAnt Gain mw 9 Indoor only 200 mw 9 Indoor only 0 mw 0 Indoor only 0 mw 0 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only Siemens Controls Reference Manual, 09/2017, C79000G8976C

90 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals 3.4 SCALANCE W778/W738 national approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol ( ) identifies all countries or frequency ranges for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: Column Country Mode CH MHz PWR MaxAntGain Meaning Country IEEE standard and the and / or DFS functionality, where required Channel Frequency Maximum permitted effective isotropic radiated power Maximum permitted antenna gain Permitted use indoors and / or outdoors 90 Reference Manual, 09/2017, C79000G8976C39206

91 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Serbia Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n 1 DFS MaxAnt Gain mw 9 Indoor + outdoor 125 mw 9 Indoor only 125 mw 0 Indoor only 25 mw 9 Indoor + outdoor Albania 11g 11n 1 mw 9 Indoor + outdoor 125 mw 9 Indoor only 40 Siemens Controls Reference Manual, 09/2017, C79000G8976C

92 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals Australia New Zealand DFS g 11n 1 DFS Bahrain 11g 11n 1 DFS Belarus 11g 11n 1 + DFS MaxAnt Gain 125 mw 0 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 2000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor 92 Reference Manual, 09/2017, C79000G8976C39206

93 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals 2 Brazil 11g 11n Cayman Islands 11g 11n 1 DFS + 2 Chile 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor + outdoor 4000 mw 9 Indoor + outdoor 200 mw 9 Indoor only 4000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 125 mw 9 Indoor only 125 mw 0 Indoor only mw 9 Indoor only mw 9 Indoor only mw 0 Indoor only Siemens Controls Reference Manual, 09/2017, C79000G8976C

94 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals DFS 149 China 11g 11n 1 DFS India 11g 11n 1 DFS Indonesia 11g 11n Japan 11g 11n 1 DFS MaxAnt Gain mw 0 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 2000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 94 Reference Manual, 09/2017, C79000G8976C39206

95 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals 11a Kazakhstan 11g 11n 1 DFS + 2 Korea 11g 11n Kuwait 11g 11n 1 DFS + Mexico 11g 11n MaxAnt Gain 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor 400 mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor 500 mw 9 Indoor + outdoor 200 mw 9 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

96 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals 149 Mozambique 11g 11n 1 DFS + 2 Oman 11g 11n 1 DFS a 11 n 149 Russia 11g 11n 1 DFS MaxAnt Gain mw 9 Indoor + outdoor 125 mw 9 Indoor only 125 mw 0 Indoor only mw 9 Indoor only 125 mw 9 Indoor only 125 mw 0 Indoor only mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor 96 Reference Manual, 09/2017, C79000G8976C39206

97 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals 2 MaxAnt Gain Siemens Controls Reference Manual, 09/2017, C79000G8976C Saudi Arabia 11g 11n 1 DFS + 2 Serbia 11g 11n 1 DFS South Africa 11g 11n 1 DFS mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 125 mw 9 Indoor only 125 mw 0 Indoor only 25 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only

98 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals 2 Singapore 11g 11n 1 DFS Thailand 11g 11n 1 11 DFS MaxAnt Gain mw 9 Indoor + outdoor 200 mw 9 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor 98 Reference Manual, 09/2017, C79000G8976C39206

99 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals MaxAnt Gain Taiwan 11g 11n 1 mw 9 Indoor + outdoor Ecuador Canada Peru USA (1) American Samoa (1) Guam (1) Northern Mariana Islands (1) US Virgin Islands (1) Siemens Controls Reference Manual, 09/2017, C79000G8976C mw 9 Indoor + outdoor mw 9 Indoor + outdoor 11g 11n 1 11 DFS g 11n 1 11 DFS mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only

100 Approvals for SCALANCE W770/W n 3.4 SCALANCE W778/W738 national approvals United Arab Emirates 11g 11n 1 DFS + (1) device of the US version 2 40 MaxAnt Gain mw 9 Indoor only 200 mw 9 Indoor only 0 mw 0 Indoor only 0 mw 0 Indoor only Reference Manual, 09/2017, C79000G8976C39206

101 Approvals for SCALANCE W760/W n Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Range of validity The approvals listed in this section apply to the following products: Product Article number Article number of the US version Access point SCALANCE W7611 RJ45 6GK57611FC000AA0 6GK57611FC000AB0 Ethernet client modules SCALANCE W7221 RJ45 (ifeatures) Article number of the IL version 6GK57221FC000AA0 6GK57221FC000AB0 6GK57221FC000AC0 SCALANCE W7211 RJ45 6GK57211FC000AA0 6GK57211FC000AB0 4.1 EC declaration of conformity The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE76181 Karlsruhe Germany You will find the current EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support ( Siemens Controls Reference Manual, 09/2017, C79000G8976C

102 Approvals for SCALANCE W760/W n 4.1 EC declaration of conformity The SIMATIC NET products described in these Operating Instructions meet the requirements of the following EC directives: 94/9/EC Directive of the European Parliament and the Council of 23 March 1994 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (until ). 2014/34/EU Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres official journal of the EU L96, 29/03/2014, pages (as of ) 1999/5/EC Directive of the European Parliament and of the Council of 1999 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity (until ). 2014/53/EU Directive of the European Parliament and of the Council of April 16, 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market.; official journal of the EU L153, 22/05/2014, pages (as of ) 2011/65/EU (RoHS) RoHS directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 1999/519/EC Council recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) ATEX ATEX directive (correct usage in potentially explosive atmospheres) The SIMATIC NET product meets the requirements of the EC directive:94/9/ec (until ) and 2014/34/EU (as of ) "Equipment and Protective Devices for in Potentially Explosive Atmospheres" according to the standards listed in the section Products (Page 104): Applied standard: 1 EN A11 Hazardous areas Part 0: Equipment General requirements 2 EN Explosive atmospheres Part 15: Equipment protection by type of protection "n" 102 Reference Manual, 09/2017, C79000G8976C39206

103 Approvals for SCALANCE W760/W n 4.1 EC declaration of conformity RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: 3 EN Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances R&TTE / RED Protection of health and safety Article 3 (1) a) protection of health and safety 4 EN A1+A2+A11+A12 Information technology equipment Safety Part 1: General requirements 5 EN Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz) EMC Art. 3 (1) b EMC 6 EN AC Railway applications Electromagnetic compatibility part 32: Railway Vehicles Devices 7 EN AC Railway applications Electromagnetic compatibility part 4: Interference emissions and immunity of signal telecommunications equipment 8 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 1 : Common technical requirements 9 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) Electromagnetic compatibility for radio equipment and services Part 17 : Siemens Controls Reference Manual, 09/2017, C79000G8976C

104 Approvals for SCALANCE W760/W n 4.1 EC declaration of conformity 10 EN 6061 Electromagnetic compatibility (EMC) Part 61: Generic standards Immunity for residential, commercial and lightindustrial environments 11 EN 6062+AC Electromagnetic compatibility (EMC) Part 62: Generic standards Immunity for industrial environments 12 EN 6063+A1+AC Electromagnetic compatibility (EMC) Part 63: Generic standards Emission standard for residential, commercial and lightindustrial environments EN 60+A1 Electromagnetic compatibility (EMC) Part : Generic standards Emission standard for industrial environments Efficient use of the radio spectrum Art. 3 (2) Efficient use of the radio spectrum 14 ETSI EN Electromagnetic compatibility and radio spectrum matters (ERM) wideband transmission systems data transmission equipment operating in the 2.4 GHz ISM band and using wideband modulation techniques. Harmonized EN containing the essential requirements according to Article 3.2 of the R&TTE directive. 15 ETSI EN Broadband Radio Access Networks (BRAN) 5 GHz high performance RLAN Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive Products CE conformity The standards that apply to the product are described in RoHS (Page 103), ATEX (Page 102) and R&TTE / RED (Page 103). Product W7611 RJ45 W7221 RJ45 W7211 RJ45 W7741 RJ45 W7341 RJ45 Standards 1, 2, 3, 4, 5, 8, 9, 10, 11, 12,, 14, 15 W7741 M12 EEC 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12,, 14, Reference Manual, 09/2017, C79000G8976C39206

105 Approvals for SCALANCE W760/W n 4.2 General approvals Certification ID The following table shows the product names and the corresponding certification ID: Product Certification ID Article number Article number of the US version Article number of the IL version W7611 RJ45 ELNW1RJE1 6GK57611FC000AA0 6GK57611FC000AB0 W7221 RJ45 ELNW1RJE1 6GK57221FC000AA0 6GK57221FC000AB0 6GK57221FC000AC0 W7211 RJ45 ELNW1RJE1 6GK57211FC000AA0 6GK57211FC000AB0 4.2 General approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support ( Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for in Potentially Explosive Atmospheres. and as of the EC directive 2014/34/EU. ATEX classification: II 3 G Ex na IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: EN (electrical apparatus for potentially explosive atmospheres; Type of protection "n") EN (Explosive atmospheres Part 0: Equipment General requirements) Siemens Controls Reference Manual, 09/2017, C79000G8976C

106 Approvals for SCALANCE W760/W n 4.2 General approvals You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex na IIC T4 Gc DEK X The products meet the requirements of the following standards: IEC (Explosive atmospheres Part 15: Equipment protection by type of protection "n") IEC (Explosive atmospheres Part 0: Equipment General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. FM The product meets the requirements of the standards: Factory Mutual Approval Standard Class Number 11 FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 culus Approval Hazardous Location culus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with UL (Information Technology Equipment) ANSI/ISA CSA C22.2 No. 2M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E2400 FCC approval This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 106 Reference Manual, 09/2017, C79000G8976C39206

107 Approvals for SCALANCE W760/W n 4.2 General approvals Notice Changes or modifications made to this equipment not expressly approved by SIEMENS may void the FCC authorization to operate this equipment. IEEE b or g operation of this product in the USA is firmwarelimited to channels 1 through 11. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. Professional Installation Notice: To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as colocated antennas transmitting the same information) is expressly forbidden. Siemens Controls Reference Manual, 09/2017, C79000G8976C

108 Approvals for SCALANCE W760/W n 4.2 General approvals Notice For use of DFS channels of the RCoax Cable Antenna 6XV187D is not permitted in channels which require dynamic frequency selection (DFS). Any installation of either a master or a client device within 35 km of a TDWR (Terminal Doppler Weather Radar) location shall be separated by at least 30 MHz (centertocenter) from the TDWR operating frequency. These devices shall be registered in the industry sponsored WISPA database, When you open this link, you get the following choices: "Search" opens a window with TDWR locations and frequencies. "r Signup" allows you to register as user of the database. After registering you can Logon and register your WLAN location. Please fill in all required information. For more information with respect to WISPA database and TWDR locations please consult FCC publication KDB D01. Note for USA, Canada, Columbia, Ecuador, Peru, Puerto Rico, Bahamas, Thailand and Uruguay When operating the SCALANCE W700 with DFS (Dynamic Frequency Selection), the IWLAN RCoax Cable 5 GHz (article number 6XV187D) may not be used in the countries listed above. CSA Information Technology Equipment CSA Certification Mark Canadian Standard Association CSA C22.2 No RSS247 of Industry Canada This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the respective Operating Instructions with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so 108 Reference Manual, 09/2017, C79000G8976C39206

109 Approvals for SCALANCE W760/W n 4.2 General approvals chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. That the device for the band MHz is only for indoor usage to reduce potential for harmful interference to cochannel mobile satellite systems. rs should also be cautioned to take note that high power radars are allocated as primary users (meaning they have priority) of MHz and MHz and these radars could cause interference and/or damage to LELAN devices. This equipment complies with IC RSS102 radiation exposure limits set forth for an uncontrolled environment. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Notice In order to comply with FCC/ISED/MIC RF Exposure requirements, this device must be installed to provide at least 20 cm separation from the human body at all times. Afin de se conformer aux exigences d'exposition RF MIC / FCC / ISED, cet appareil doit être installé pour fournir au moins 20 cm de séparation du corps humain en tout temps. RCM The product meets the requirements of the AS/NZS 20 standard (Class A). Approvals for Argentina Devices of the SCALANCE W760/W720 series are approved in Argentina under the following certification number: Certification ID Certification number ELNW1RJE1 CNC: C172 Devices of the SCALANCE W770/W730 series are approved in Argentina under the following certification numbers: Certification ID Certification number MSNW1RJE2 CNC: C1 MSNW1M12E2 CNC: C163 Siemens Controls Reference Manual, 09/2017, C79000G8976C

110 Approvals for SCALANCE W760/W n 4.2 General approvals Approval for Brazil Devices of the SCALANCE W760/W720 series are approved in Brazil under the following certification numbers: Este equipamento opera em caráter secundário, isto, ist é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. KCC Statement (Republic of Korea) 사용자안내문 ( 제 5 조제 1 항제 1 호관련 ) 기종별 A 급기기급기기 ( 업무용방송통신기기 ) 사용자안내문 이기기는업무용 (A 급 ) 으로전자파적합등록을한 (A 급 ) 으로전자파적합등록을한 기기이오니판매자또는사용자는이점을 주의하시기바라며, 가정외의지역에서사용하는 것을목적으로합니다. " 당해무선설비는전파혼신가능성이있으므로인명안전과관련된서비스는할수없음 " Approval for Mexico Devices of the SCALANCE W760/W720 series are approved in Mexico under the following certification number: RCPSIEL150096A1 Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) 110 Reference Manual, 09/2017, C79000G8976C39206

111 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals 4.3 SCALANCE W760/W720 national approvals The following table lists the countries in which the SCALANCE W700 product is approved. The diamond symbol ( ) identifies all countries or frequency ranges for which there was no approval at the time these operating instructions were written. The current status of the approvals can be found on the Internet at the following address: Column Country Mode CH MHz PWR MaxAntGain Meaning Country IEEE standard and the and / or DFS functionality, where required Channel Frequency Maximum permitted effective isotropic radiated power Maximum permitted antenna gain Permitted use indoors and / or outdoors Siemens Controls Reference Manual, 09/2017, C79000G8976C

112 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals Andorra Belgium Bosnia and Herzegovina Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Croatia Latvia Liechtenstein Lithuania Luxembourg Malta Macedonia Monaco Montenegro Netherlands Norway Austria Poland Portugal Romania San Marino Sweden Switzerland Serbia Slovakia Slovenia Spain Czech Republic Turkey Hungary Vatican Cyprus 11g 11n 1 DFS MaxAnt Gain mw 9 Indoor + outdoor 200 mw 9 Indoor only Egypt (1), (2) 11g 11n 1 mw 9 Indoor + outdoor 112 Reference Manual, 09/2017, C79000G8976C39206

113 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals DFS + MaxAnt Gain Siemens Controls Reference Manual, 09/2017, C79000G8976C Albania 11g 11n 1 DFS + 2 Angola 11g 11n 1 DFS + 2 Argentina 11g 11n mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 0 mw 9 Indoor + outdoor 50 mw 9 Indoor + outdoor 250 mw 0 Indoor + outdoor

114 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals Australia New Zealand g 11n 1 DFS Bahrain 11g 11n 1 DFS Belarus 11g 11n 1 + DFS MaxAnt Gain 250 mw 0 Indoor + outdoor 250 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 2000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor 114 Reference Manual, 09/2017, C79000G8976C39206

115 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals Brazil 11g 11n Cayman Islands 11g 11n 1 DFS + 2 Chile 11g 11n 1 DFS+ DFS 149 China 11g 11n MaxAnt Gain 4000 mw 9 Indoor + outdoor 200 mw 9 Indoor only 4000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor only mw 9 Indoor only mw 0 Indoor only mw 0 Indoor only mw 9 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

116 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals DFS+ 149 Ivory Coast 11g 11n 1 DFS + 2 Guatemala 11g 11n 1 11 DFS MaxAnt Gain 200 mw 9 Indoor only 2000 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only Reference Manual, 09/2017, C79000G8976C39206

117 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals Hong Kong 11g 11n 1 DFS + 2 India 11g 11n 1 DFS Indonesia 11g 11n Israel (2) 11g 11n 1 DFS MaxAnt Gain mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw Indoor + outdoor 200 mw Indoor only 200 mw Indoor only Siemens Controls Reference Manual, 09/2017, C79000G8976C

118 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals Japan 11g 11n 1 DFS + 11a Kazakhstan 11g 11n 1 DFS + 2 Qatar 11g 11n Korea 11g 11n Kuwait 11g 11n MaxAnt Gain mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 9 Indoor only mw 0 Indoor only 400 mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor 118 Reference Manual, 09/2017, C79000G8976C39206

119 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals DFS + Macau 11g 11n MaxAnt Gain mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 6 Indoor + outdoor mw 0 Indoor + outdoor Madagascar 11g 11n 1 DFS Malaysia 11g 11n 1 DFS Mexico 11g 11n mw 9 Indoor only 200 mw 9 Indoor only 0 mw 0 Indoor only 0 mw 0 Indoor only 400 mw 0 Indoor only 200 mw 9 Indoor + outdoor 500 mw 9 Indoor + outdoor mw 9 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

120 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals 149 Pakistan 11g 11n Russia 11g 11n 1 DFS + 2 Saudi Arabia 11g 11n 1 Singapore Philippines DFS + 11b 11g 11n MaxAnt Gain mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 9 Indoor + outdoor mw 9 Indoor + outdoor mw 0 Indoor + outdoor mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor + outdoor 120 Reference Manual, 09/2017, C79000G8976C39206

121 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals DFS South Africa 11g 11n 1 DFS+ 2 Thailand 11g 11n 1 11 DFS MaxAnt Gain 200 mw 0 Indoor + outdoor mw 9 Indoor + outdoor 200 mw 9 Indoor only mw 9 Indoor + outdoor 200 mw 9 Indoor only 200 mw 0 Indoor + outdoor Siemens Controls Reference Manual, 09/2017, C79000G8976C

122 Approvals for SCALANCE W760/W n 4.3 SCALANCE W760/W720 national approvals Bahamas Canada Colombia Peru Puerto Rico Uruguay USA (3) American Samoa (3) Guam (3) Northern Mariana Islands (3) US Virgin Islands (3) 11g 11n 1 11 DFS Venezuela 11g 11n 1 United Arab Emirates DFS g 11n 1 DFS MaxAnt Gain mw 9 Indoor + outdoor 200 mw 9 Indoor only 0 mw 9 Indoor + outdoor 200 mw 9 Indoor only 0 mw 0 Indoor only 4000 mw 0 Indoor + outdoor mw 9 Indoor only 200 mw 9 Indoor only 0 mw 0 Indoor only 0 mw 0 Indoor only 122 Reference Manual, 09/2017, C79000G8976C39206

Approvals SCALANCE W n SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE. W780 / W

Approvals SCALANCE W n SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE. W780 / W Approvals for SCALANCE W780 / W740 802.11n 1 Approvals for SCALANCE W788C / W786C 802.11n 2 SIMATIC NET Approvals for SCALANCE W760 / W720 / W770 / W730 3 802.11n Industrial Wireless LAN Approvals SCALANCE

More information

Approvals SCALANCE W n SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE. W780 / W

Approvals SCALANCE W n SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE. W780 / W Approvals for SCALANCE W780 / W740 802.11n 1 Approvals for SCALANCE W788C / W786C 802.11n 2 SIMATIC NET Approvals for SCALANCE W760 / W720 / W770 / W730 3 802.11n Industrial Wireless LAN Approvals SCALANCE

More information

Approvals SCALANCE W n SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE. W780 / W

Approvals SCALANCE W n SIMATIC NET. Industrial Wireless LAN Approvals SCALANCE W n. Approvals for SCALANCE. W780 / W Approvals for SCALANCE W780 / W740 802.11n 1 Approvals for SCALANCE W788C / W786C 802.11n 2 SIMATIC NET Approvals for SCALANCE W760 / W720 / W770 / W730 3 802.11n Industrial Wireless LAN Approvals SCALANCE

More information

Industrial Wireless LAN Radio Country Approvals for IWLAN Devices

Industrial Wireless LAN Radio Country Approvals for IWLAN Devices SIMATIC NET Industrial Wireless LAN Radio Country Approvals for IWLAN Devices 2017-10-16 Frei verwendbar www.siemens.com/simatic-net Approvals for Simatic Ident products can be found: http://www.siemens.com/rfid-approvals

More information

User Manual. MITSUMI WiFi Module MODEL DWM-W081

User Manual. MITSUMI WiFi Module MODEL DWM-W081 Page 1 of 7 User Manual MITSUMI WiFi Module MODEL DWM-W081 The purpose of this manual is to explain correct way how to integrate module DWM-W081 to the end product. It includes procedures that shall assist

More information

Sure Cross Radio Certifications

Sure Cross Radio Certifications Sure Cross Radio Certifications Banner's Sure Cross product line is certified by the FCC, European Union, and many other countries for operation within specific radio frequencies. FCC Certification, 900MHz

More information

Declarations of Conformity and Regulatory Information

Declarations of Conformity and Regulatory Information APPENDIXB Declarations of Conformity and Regulatory Information This appendix provides declarations of conformity and regulatory information for the Cisco Aironet 1200 Series Access Point. This appendix

More information

EE1941/EN1941/EN One-Way Binary RF Module Installation and Operation Manual

EE1941/EN1941/EN One-Way Binary RF Module Installation and Operation Manual EE1941/EN1941/EN1941-60 One-Way Binary RF Module Installation and Operation Manual 1 Overview EchoStream RF modules are designed to be easily interfaced with your electronic remote application controller

More information

EE1941XS/EN1941XS One-Way Serial RF Module Installation and Operation Manual

EE1941XS/EN1941XS One-Way Serial RF Module Installation and Operation Manual EE1941XS/EN1941XS One-Way Serial RF Module Installation and Operation Manual 1 Overview EchoStream RF modules are designed to be easily interfaced with your electronic remote application controller (RAC).

More information

APM 6998 WiFi Module Manual

APM 6998 WiFi Module Manual Host Revision Information APM 6998 WiFi Module Manual Host Hardware Revision Host Module Driver Version Module Hardware Revision T3x Rev D1 v8.1.4.4 001E Host PCB Design Guidelines The following guidelines

More information

RFC1000-CE Cloud Relay. MadgeTech Cloud Services Data Logger Hub. Product User Guide

RFC1000-CE Cloud Relay. MadgeTech Cloud Services Data Logger Hub. Product User Guide RFC1000-CE Cloud Relay MadgeTech Cloud Services Data Logger Hub Product User Guide Product User Guide Table of Contents Product Overview... 3 Getting Started... 3 Setting Up the RFC1000-CE Cloud Relay...

More information

CARE +MAINTENANCE Cleaning Important Safety Instructions Water Drop Heat Battery Charging Repair

CARE +MAINTENANCE Cleaning Important Safety Instructions Water Drop Heat Battery Charging Repair CARE +MAINTENANCE Cleaning 1. Wipe with a dry cloth. 2. Rinse with fresh water after exposure to soap, chlorine or seawater. 3. Do not use solvents, chemicals, cleaning solutions, alcohol, ammonia or abrasives.

More information

Transponder Reader TWN4 MultiTech 3 Quick Start Guide

Transponder Reader TWN4 MultiTech 3 Quick Start Guide Transponder Reader TWN4 MultiTech 3 Quick Start Guide Rev. 1.0 1. Introduction The transponder reader TWN4 is a device for reading and writing RFID transponders. There are different versions of TWN4 devices

More information

Regulatory status for using RFID in the UHF spectrum 3 May 2006

Regulatory status for using RFID in the UHF spectrum 3 May 2006 Regulatory status for using RFID in the UHF spectrum 3 May NOTE: The following countries were updated since the last publication of 3 March : Thailand, Romania. The table attached provides an overview

More information

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01 SIMATIC RTLS Localization systems (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure

More information

ACUII-06 User Manual (NAS)

ACUII-06 User Manual (NAS) 1(14) ACUII-06 User Manual (NAS) Content 2(14) 1 General... 3 1.1 history... 3 1.2 Abbreviations... 3 1.3 References... 3 2 Introduction... 4 3 Technical Description... 5 3.1 Connectors... 5 3.1.1 WLAN

More information

The compact test- disconnect terminal interface system for protection and secondary technology

The compact test- disconnect terminal interface system for protection and secondary technology POCON POWER Connector The compact test- disconnect terminal interface system for protection and secondary technology POCON the compact test-disconnect terminal interface system Safe control and testing

More information

General Safety and Precautions 1. Read all of the information in the owner s manual and other included product information in the packaging before

General Safety and Precautions 1. Read all of the information in the owner s manual and other included product information in the packaging before General Safety and Precautions 1. Read all of the information in the owner s manual and other included product information in the packaging before operating the product. 2. Prolonged exposure to alarm

More information

Link Mobile Gateway User Guide A ProVIEW System Component

Link Mobile Gateway User Guide A ProVIEW System Component A ProVIEW System Component Omni-ID office locations: US UK China India Southeast Asia Germany 1. CONTENTS 1. Introduction... 3 About this Document... 3 Related Products... 3 Regulatory Approvals... 4 Certifications...

More information

Murata Bluetooth mesh Node. Installation Guide

Murata Bluetooth mesh Node. Installation Guide Murata Bluetooth mesh ode Installation Guide Shipped Components Murata Bluetooth mesh ode (BCC2ZZ1PR) ocknut Page 1 Caution Installation and maintenance must be done in accordance with local, state and

More information

Display Modules A309/A310

Display Modules A309/A310 ESC - + - MANUAL Special Documentation Display Modules A309/A310 Radio Approvals for WLAN Interface SD01965O/06/EN/03.17 71382452 ESC + E About this document Display modules A309/A310 1 About this document

More information

User guide. SmartTags. NT3/SmartTagsST25a

User guide. SmartTags. NT3/SmartTagsST25a User guide SmartTags NT3/SmartTagsST25a Contents Introduction...3 What are SmartTags?... 3 Getting started... 4 Turning on the NFC function... 4 NFC detection area... 4 Smart Connect... 4 Using SmartTags...

More information

Regulatory Compliance Statement

Regulatory Compliance Statement Regulatory Compliance Statement EU Declaration of Conformity Model N905 and Model N905B Model N905C The declaration of conformity may be consulted at www.kobo.com/userguides SAR Limits The exposure standard

More information

Polycom VoxBox Bluetooth/USB Speakerphone

Polycom VoxBox Bluetooth/USB Speakerphone SETUP SHEET Polycom VoxBox Bluetooth/USB Speakerphone 1725-49004-001C Package Contents Micro USB Cable 1.21 m 4 ft Carrying Case Security USB Cable 3 m 10 ft L-Wrench Optional Accessories Security USB

More information

Vehicle IoT Gateway VG34 DATASHEET OVERVIEW HIGHLIGHTS

Vehicle IoT Gateway VG34 DATASHEET OVERVIEW HIGHLIGHTS Vehicle IoT Gateway VG34 DATASHEET OVERVIEW The VG34 Vehicle IoT Gateway is an advanced sensor platform for fleets, providing operators with real-time location and analytics, sensor data, WiFi hotspot

More information

Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100)

Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100) Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100) 822-2210-001 CPN 963-4891-001 Rev - NOTICE: The contents of this document are proprietary to Rockwell Collins, Inc. and shall

More information

User Manual for 24 GHz Blind-Spot Radar Sensor

User Manual for 24 GHz Blind-Spot Radar Sensor User Manual for 24 GHz Blind-Spot Radar Sensor SRR2-A Department: 1 of 13 AUTHORS Name Organisation Section Frank Gruson Continental, Frequency Management WW Issue Document Date of Issue Document Owner

More information

2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES

2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES 2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES 1. INTRODUCTION These HCT Transition Period Official Competition Rules ( Official Rules ) govern how players earn Hearthstone Competitive Points

More information

DOWNLOAD KASA ADD TO KASA INSTALL AND POWER UP SAFETY FIRST

DOWNLOAD KASA ADD TO KASA INSTALL AND POWER UP SAFETY FIRST WELCOME TO KASA Let s get started with your new Wi-Fi Smart Dimmer. Kasa SAFETY FIRST Read and follow all safety precautions in the Kasa app. Ensure power is off at the circuit breaker before removing

More information

User s Manual Wireless Keyboard/Mouse & NANO Receiver MD-5110/MM-5110 & DG-5110

User s Manual Wireless Keyboard/Mouse & NANO Receiver MD-5110/MM-5110 & DG-5110 User s Manual Wireless Keyboard/Mouse & NANO Receiver MD-5110/MM-5110 & DG-5110 Page 1 of 7 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device,

More information

802.11a/n/b/g/ac WLAN Module AMB7220

802.11a/n/b/g/ac WLAN Module AMB7220 AboCom 802.11a/n/b/g/ac WLAN Module AMB7220 User s Manual FCC Certification Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for

More information

stripax The professional stripping tool

stripax The professional stripping tool stripax The professional stripping tool stripax the original: developed from experience Weidmüller is the world s leading manufacturer of solutions for electrical connectivity, transmission, conditioning

More information

Wireless Compliance Statements

Wireless Compliance Statements Wireless Compliance Statements Visual Coaching Device 13485 P1015323-001-A DECEMBER 2015 Document ID Document Title Abstract Manufacturer P1015323-001-A Wireless Compliance Statements Visual Coaching Device

More information

PA421B PA821B. Front Panels. Included Components. Features. Model Variations. Antenna Combiner

PA421B PA821B. Front Panels. Included Components. Features. Model Variations. Antenna Combiner Antenna Combiner WARNING: This product contains a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. General Description Shure antenna combiners actively

More information

BT11 Hardware Installation Guide

BT11 Hardware Installation Guide Overview The Mist BT11 delivers a BLE Array AP with internal antennas that are used for BLE based location. 1 Understanding the Product Included in the box: BT11 Mounting bracket with mounting hardware

More information

User Manual. 1. Introduction. 2. Features

User Manual. 1. Introduction. 2. Features 1. Introduction User Manual AMPAK Technology would like to announce a low-cost and low-power consumption module which has all of the Wi-Fi functionalities. The highly integrated module makes the possibilities

More information

LOUIS VUITTON 1. Louis Vuitton Echo, locate your Horizon luggage in airports Battery indicator light. Light sensor to detect opening

LOUIS VUITTON 1. Louis Vuitton Echo, locate your Horizon luggage in airports Battery indicator light. Light sensor to detect opening L E A F L E T - Louis Vuitton Echo, locate your Horizon luggage in airports Battery indicator light Light sensor to detect opening ON/OFF switch Micro-USB port for charger 3. Open LV PASS. Go to Connected

More information

5.8G Wireless Audio Transceiver/Receiver Module DWHP83

5.8G Wireless Audio Transceiver/Receiver Module DWHP83 5.8G Wireless Audio Transceiver/Receiver Module DWHP83 1. Module dimensions and layout 2. Antenna info Brand: EDIFIER Antenna type: PCB Max Peak gain: 5.36 dbi 3. Feature: DARR83 Wireless Audio Processor

More information

Pser G uide oduct Manual

Pser G uide oduct Manual ADC-T2000 Hub User Product Guide Manual Hub Product Manual 1 Set Up Required Standard home router with active Internet connection Z-Wave devices to be installed Indicator Lights White Flashing: no internet

More information

User Manual. 1. Introduction. 2. Features

User Manual. 1. Introduction. 2. Features 1. Introduction User Manual AMPAK Technology would like to announce a low-cost and low-power consumption module which has all of the WiFi and Bluetooth functionalities. The highly integrated module makes

More information

Audio/video, Information and Communication Technology Equipment - Part 1:

Audio/video, Information and Communication Technology Equipment - Part 1: TO WHOM IT MAY CONCERN Product Test Report Bosch Torenallee 49 5617 BA Eindhoven The Netherlands BT-SC 2018-E-054 Product FLEXIDOME IP starlight 8000i F.01U.321.595 NDE-8502-R Fixed dome 2MP HDR 3-9mm

More information

DCH-G020 mydlink Connected Home Hub

DCH-G020 mydlink Connected Home Hub DCH-G020 mydlink Connected Home Hub User s Manual Version 01.0 Oct. 15 th, 2014 Manual Page 1 10/16/2014 1. PRODUCT DESCRIPTION The DCH-G020 is a Connected Home Z-Wave Gateway used to control a variety

More information

16+ HS300. Instructions for use. One Key Start/One Key Landing Function Headless Mode / One Key Return Altitude Hold Mode

16+ HS300. Instructions for use. One Key Start/One Key Landing Function Headless Mode / One Key Return Altitude Hold Mode 16+ HS300 Instructions for use One Key Start/One Key Landing Function Headless Mode / One Key Return Altitude Hold Mode usa@holystone.com ca@holystone.com By scanning the QR code or searching Holy Stone

More information

Brochure More information from

Brochure More information from Brochure More information from http://www.researchandmarkets.com/reports/1342464/ The World Market for Stranded Wire, Cable, Ropes, and Plaited Bands of Iron, Steel, Copper, or Aluminum Excluding Electrically

More information

Shields. Outdoor Shields Owner s Manual. Avoidance Solutions.

Shields. Outdoor Shields Owner s Manual. Avoidance Solutions. Shields Avoidance Solutions Outdoor Shields Owner s Manual www.invisiblefence.com Important Precautions Invisible Fence Brand systems have protected over two million pets. However, there are some precautions

More information

MOVADO.COM/SMARTSUPPORT

MOVADO.COM/SMARTSUPPORT LANGUAGES ENGLISH... 3 FRANÇAIS... 4 ESPAÑOL... 5 REGULATORY INFORMATION... 6 MOVADO CONNECT POWERED BY ANDROID WEAR DOWNLOAD THE APP & GET STARTED AT MOVADO.COM/SMARTSUPPORT 3 MOVADO CONNECT POWERED BY

More information

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in Spires @caprosser 1 What do we want to know about the audience for academic blogging?

More information

Electronic Emission Notices

Electronic Emission Notices Electronic Emission Notices - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - The following information refers to the Lenovo Active pen. Federal

More information

System Requirements: D-Link Systems, Inc.

System Requirements: D-Link Systems, Inc. System Requirements: Minimum System Requirements: CD-ROM Drive Computers with Windows, Macintosh, or Linux-based operating systems Installed Ether net Adapter Internet Explorer version 6.0 or Netscape

More information

Icon Description UP ( ) 1 BACK ( ) 4 PAGE ( )

Icon Description UP ( ) 1 BACK ( ) 4 PAGE ( ) EN 1 1 BACK ( ) Press to return to the previous page or cancel an operation. When recording, press to pause recording. Press it again to stop recording. 2 LAP/OK ( ) In Menu, press to enter or confirm

More information

FCC Certification Notice: IC Certification

FCC Certification Notice: IC Certification Users Manual VP4450 FCC Certification This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)

More information

StreamStick by NAV-TV is a USB-powered, HI-FI Bluetooth 4.0 audio streaming module for automotive and home use. Make ANY stereo (equipped with AUX

StreamStick by NAV-TV is a USB-powered, HI-FI Bluetooth 4.0 audio streaming module for automotive and home use. Make ANY stereo (equipped with AUX StreamStick by NAV-TV is a USB-powered, HI-FI Bluetooth 4.0 audio streaming module for automotive and home use. Make ANY stereo (equipped with AUX input) a Bluetooth-audio receiver! Using the StreamStick

More information

FOR AVLEX ONLY MT-24A. User Guide. 2.4 GHz Digital Stationary Transmitter

FOR AVLEX ONLY MT-24A. User Guide. 2.4 GHz Digital Stationary Transmitter 2.4 GHz Digital Stationary Transmitter User Guide All rights reserved. MN 017/05 Do not copy or forward without prior approvals MIPRO. Specifications and design subject to change without notice. 2 CE5

More information

HistoCore SPECTRA CV. RFID-Registration Registro de RFID Registro RFID تسجيل التعريف عن طريق الترددات الالسلكية

HistoCore SPECTRA CV. RFID-Registration Registro de RFID Registro RFID تسجيل التعريف عن طريق الترددات الالسلكية HistoCore SPECTRA CV RFID-Registration Registro de RFID Registro RFID تسجيل التعريف عن طريق الترددات الالسلكية Version 1.1, Revision B 08.2018 RFID-Registration HistoCore SPECTRA CV Order No.: 14 0514

More information

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

1204 Reflected Wave Reduction Device

1204 Reflected Wave Reduction Device Instructions 1204 Reflected Wave Reduction Device (Catalog Number 1204-RWR2-09-B, C) This publication will guide you through installation (including mounting, wiring and grounding procedures) of the 1204

More information

TECHNICAL CUSTOMER DOCUMENTATION TCD MRR1Crn / MRR1CrnCR Hardware Part 5 - Radio Frequency Homologation: marking and user manual phrases

TECHNICAL CUSTOMER DOCUMENTATION TCD MRR1Crn / MRR1CrnCR Hardware Part 5 - Radio Frequency Homologation: marking and user manual phrases CC-DA/ECR Issue Date: 07.11.2017 Dept.: CC-DA/ECR5 Name: Velten Page: 1 of 19 Modifications No. Date/Reviser Chapter Description of modification 1 18.12.2013 Ernst 2 23.01.2014 1 all 2 5 Initial version

More information

StreetSounds STS-170-MMST Mobile Master. User Guide

StreetSounds STS-170-MMST Mobile Master. User Guide StreetSounds STS-170-MMST Mobile Master User Guide V1.4 June 3, 2018 1 CONTENTS 1 Introduction... 3 1.1 Mobi Front Panel... 3 1.2 Mobi Rear Panel... 4 1.3 Operating the Mobi... 4 2 FCC Statements... 6

More information

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller Kit XWS Package Contents:

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller Kit XWS Package Contents: READ ME FIRST QUICK INSTALL GUIDE Wireless Controller Kit XWS-1310 Package Contents: XWC-1000 Wireless Controller Rack Mount Kit Power Cord XAP-310 Access Points XFS-1054P PoE Switch BEFORE YOU BEGIN INSTALLATION

More information

FOR TRAINING PURPOSES ONLY DATED MATERIAL. Aperio Hub AH20/AH30 Installation Instructions. ASSA ABLOY, the global leader in door opening solutions

FOR TRAINING PURPOSES ONLY DATED MATERIAL. Aperio Hub AH20/AH30 Installation Instructions. ASSA ABLOY, the global leader in door opening solutions perio Hub H20/H30 Installation Instructions Covers WL-260 3 May 2011 SS LOY, the global leader in door opening solutions 1 H20/H30 - Table of Contents 2 H20/H30 - FCC and Industry Canada Statements 3 H20/H30

More information

USB WiFi for Projector

USB WiFi for Projector USB WiFi for Projector User s Manual Brand:acer lmodel:uwa2 Rev. 1.01 FCC statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15

More information

GNSS multiconstellation, GPS+Glonass as a minimum; GSM; Accelerometer; SIM on Chip; Watch Dog; Power Management; RF transceiver; CAN Bus interface

GNSS multiconstellation, GPS+Glonass as a minimum; GSM; Accelerometer; SIM on Chip; Watch Dog; Power Management; RF transceiver; CAN Bus interface ZTE AT21 User Guide 1.1 Reference Architecture The reference architecture of the Kernel module is shown here below The main HW architecture features and physical constraints are summarized below: GNSS

More information

Regulatory Compliance Statement

Regulatory Compliance Statement Regulatory Compliance Statement EU Declaration of Conformity The declaration of conformity may be consulted at www.kobo.com/userguides SAR Limits The exposure standard for wireless devices employs a unit

More information

TomTom Touch Fitness Tracker User Manual

TomTom Touch Fitness Tracker User Manual TomTom Touch Fitness Tracker User Manual Contents Addendum 3 2 Addendum Warnings & Indications for use Indications for use TomTom Touch Fitness Tracker tracks Body Composition (body fat and muscle mass),

More information

Avery Dennison ICS Performance Guarantee Sign Cut and Wrapping Films Durability Bulletin 2.0

Avery Dennison ICS Performance Guarantee Sign Cut and Wrapping Films Durability Bulletin 2.0 Sign Cut and Wrapping Films Durability Bulletin 2.0 EU Revision number: 3 Date: 062016 ICS PERFORMANCE GUARANTEE The ICS Performance Guarantee combines our films with other qualified components to form

More information

Blue Node. User Manual

Blue Node. User Manual Blue Node User Manual CONTACT US LX Suite 101, 4 Cornwallis St, Eveleigh, 2015 National Innovation Centre Australian Technology Park Sydney, Australia +612 9209 4133 IoTCores.com.au LX IoT Cores Blue Node

More information

Group of Administrative Co-operation Under the R&TTE Directive. 5 th R&TTE Market Surveillance Campaign on WLAN 5 GHz

Group of Administrative Co-operation Under the R&TTE Directive. 5 th R&TTE Market Surveillance Campaign on WLAN 5 GHz Group of Administrative Co-operation Under the R&TTE Directive Ref. Ares(2015)1723904-23/04/2015 5 th R&TTE Market Surveillance Campaign on WLAN 5 GHz REPORT ON THE 5 TH JOINT CROSS-BORDER R&TTE MARKET

More information

ihealth Wireless Body Analysis Scale OWNER S MANUAL

ihealth Wireless Body Analysis Scale OWNER S MANUAL ihealth Wireless Body Analysis Scale OWNER S MANUAL TABLE OF CONTENTS INTENDED USE... 2 IMPORTANT NOTE FOR USERS... 2 CONTRAINDICATION... 2 OFFLINE MEMORY... 3 SPECIFICATIONS... 3 GENERAL SAFETY AND PRECAUTIONS...

More information

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4 Characteristics 1 Ordering data 2 SIMATIC Ident RFID systems Operating Instructions Installing and mounting 3 Connecting the antenna 4 Antenna parameter assignment 5 Antenna patterns 6 Maximum read/write

More information

STREETSOUNDS STS-170-FMST USER GUIDE V1.0. Fixed Master STS-170-FMST. User Guide V1.1 August 25,2018

STREETSOUNDS STS-170-FMST USER GUIDE V1.0. Fixed Master STS-170-FMST. User Guide V1.1 August 25,2018 Fixed Master STS-170-FMST User Guide V1.1 August 25,2018 1 1 TABLE OF CONTENTS 2 Introduction... 3 3 Outdoor Unit (ODU)... 3 4 Indoor Unit (IDU)... 4 5 Optonal High Gain Antenna Assembly... 5 6 Pole Mount...

More information

260X190mm/105 克铜版纸 / 黑白印刷

260X190mm/105 克铜版纸 / 黑白印刷 260X190mm/105 克铜版纸 / 黑白印刷 5172301 1 FEATURES A-Control Panel A1-Bass Volume Adjustment A2-Volume Adjustment A3-Audio Input Jack A4-Audio Output Jack for linking multiple chairs A5-Wire mode / Bluetooth

More information

PO01275C Tabor East Neighborhood Meeting. Monday, April 20, :30 PM 8:30 PM

PO01275C Tabor East Neighborhood Meeting. Monday, April 20, :30 PM 8:30 PM PO01275C Tabor East Neighborhood Meeting Monday, April 20, 2015 6:30 PM 8:30 PM 1 Opening Remarks, Introductions, Explanation of Agenda and Procedure Lenny Borer Moderator 2 Portland Office for Community

More information

Need Help? SA /

Need Help? SA / 1 FEATURES A-Control Panel A1-Vibration adjustment A2-Bass Volume Adjustment A3-Volume Adjustment A4-Audio Input Jack A5-Audio Output Jack for linking multiple chairs A6-Wire mode / Bluetooth mode Switch

More information

WML- 46### User Manual

WML- 46### User Manual Page 1 of 6 WML- 46### User Manual The purpose of this manual is to explain correct way how to integrate module WML- 46### to the end product. It includes procedures that shall assist you to avoid unforeseen

More information

Frame through-beam sensors

Frame through-beam sensors Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection

More information

OPERATION MANUAL WARNING

OPERATION MANUAL WARNING TM OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT. PATENT PENDING - COPYRIGHT 2014 - APPION INC. - ALL RIGHTS RESERVED Introduction

More information

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information IMPORTANT! Visit http://support.proxim.com for the latest safety and regulatory compliance information for this product. ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance

More information

Table of Contents Executive Summary 29

Table of Contents Executive Summary 29 Contents Table of Contents Executive Summary 29 Section 1: Introduction 33 Section 2: World 37 2.1.1. Main consumers 37 2.1.2. Main producers 2015 and 2016 39 2.1.3. Main importers 2015 and 2016 40 2.1.4.

More information

Monthly Summary of Troop Contribution to UN Operations

Monthly Summary of Troop Contribution to UN Operations Monthly Summary of Troop Contribution to UN Operations Month of Report : 3-Dec-3 Country Description of Post M F Totals ) Albania Individual Police............ 0 Subtotal for Country ) Algeria Experts

More information

User Guide. Do not copy or forward without prior approvals MIPRO. Specifications and design subject to change without notice.

User Guide. Do not copy or forward without prior approvals MIPRO. Specifications and design subject to change without notice. User Guide ACT-70H / ACT-71Ha ACT-71H / ACT-72H All rights reserved. MN 016/01 Do not copy or forward without prior approvals MIPRO. Specifications and design subject to change without notice. 2 CE5 2

More information

INSTALLATION MANUAL ES-SUB-WIRELESS-KIT ES-SUB-WIRELESS-RCVR

INSTALLATION MANUAL ES-SUB-WIRELESS-KIT ES-SUB-WIRELESS-RCVR INSTALLATION MANUAL ES-SUB-WIRELESS-KIT ES-SUB-WIRELESS-RCVR FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC

More information

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM DATA SHEET CISCO ONS 15216 50/100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS 15454 MULTISERVICE TRANSPORT PLATFORM The Cisco ONS 15216 50/100-GHz Interleaver/De-interleaver is an advanced 50/100-GHz

More information

800 Series Transmitters Owner s Manual

800 Series Transmitters Owner s Manual 800 Series Transmitters Owner s Manual www.invisiblefence.com www.invisiblefence.com Important Precautions Invisible Fence Brand pet containment systems have contained over two million pets. However, there

More information

Regulatory Compliance and Important Safety Information

Regulatory Compliance and Important Safety Information Regulatory Compliance and Important Safety Information Regulatory Certification/Approval Marks for your device can be found in Settings > About Kobo Glo HD EU Declaration of Conformity A copy of the EU

More information

Car AVN User Manual. Model Name : LC7F

Car AVN User Manual. Model Name : LC7F Car AVN User Manual Model Name : LC7F 1. Overview and Specifications (1) Overview 1) The Infotainment system provides Infotainment in your car, using the latest technology. See your dealer to have the

More information

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D EE1941/EN1941 One-Way Binary RF Module nstallation and Operation Manual - 06287D 1 Overview EchoStream RF modules are designed to be easily interfaced with your electronic remote application controller

More information

or call

or call Email service@acecasual.com or call 1 FEATURES A-Control Panel A1-Vibration adjustment A2-Bass Volume Adjustment A3-Volume Adjustment A4-Audio Input Jack A5-Audio Output Jack for linking multiple chairs

More information

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E EE1941/EN1941 One-Way Binary RF Module nstallation and Operation Manual - 06287E 1 Overview EchoStream RF modules are designed to be easily interfaced with your electronic remote application controller

More information

2011 Shure Incorporated 27A15021 (Rev. 2) *27A15021* Printed in China

2011 Shure Incorporated 27A15021 (Rev. 2) *27A15021* Printed in China TM ShowLink TM Wireless Access Point 2011 Shure Incorporated 27A15021 (Rev. 2) *27A15021* Printed in China ShowLink Access Point The ShowLink access point enables real-time remote control of the Axient

More information

NFC Forum: The Evolution of a Consortium

NFC Forum: The Evolution of a Consortium NFC Forum: The Evolution of a Consortium Presented by Greg Kohn Sr. Operations Director, NFC Forum ANSI Open Forum: Building Bridges across the Standards Ecosystem October 9, 2012 Part of the World Standards

More information

Manual Unihan UPWL6580

Manual Unihan UPWL6580 Manual Unihan UPWL6580 Federal Communications Commission Statement This device complies with FCC Rules Part 15. Operation is subject to the following i. This device may not cause harmful interference,

More information

v Pairing Instructions for: GENERAL MOTORS REPLACEMENT FLIP KEYS

v Pairing Instructions for: GENERAL MOTORS REPLACEMENT FLIP KEYS v1.0618 Pairing Instructions for: GENERAL MOTORS REPLACEMENT FLIP KEYS PAIRING INSTRUCTIONS To successfully perform these pairing instructions, an original, working key must be present. If an original,

More information

FMT4R FM Transmitter User s manual

FMT4R FM Transmitter User s manual FMT4R FM Transmitter User s manual Contents 1. Overview.....1 2. Getting started 1 3. Basic operation...2 4. Care and maintenance...3 5. Frequently asked questions....3 6. Technical parameter..4 It is

More information

Economic Outlook for 2016

Economic Outlook for 2016 Economic Outlook for 2016 Arturo Bris Professor of Finance, IMD Director, IMD World Competitiveness Center Yale International Center for Finance European Corporate Governance Institute 2015 IMD International.

More information

Ethernet Gateway User Manual

Ethernet Gateway User Manual Ethernet Gateway User Manual Table of Contents Introduction At a Glance Getting Started Ethernet Gateway Setup via DHCP Ethernet Gateway Setup via Static IP Jacks, Buttons, and Ports Troubleshooting the

More information

RWSS5510 RWSS9500. EN User manual. DE Benutzerhandbuch. ES Manual del usuario. FR Mode d emploi. Manuale utente. NL Gebruiksaanwijzing

RWSS5510 RWSS9500. EN User manual. DE Benutzerhandbuch. ES Manual del usuario. FR Mode d emploi. Manuale utente. NL Gebruiksaanwijzing Register your product and get support at www.philips.com/welcome RWSS5510 RWSS9500 User manual DE Benutzerhandbuch ES Manual del usuario FR Mode d emploi IT Manuale utente NL Gebruiksaanwijzing PT-BR Manual

More information

Alcatel-Lucent 8340 Smart IP-DECT AP. Installation Manual

Alcatel-Lucent 8340 Smart IP-DECT AP. Installation Manual 8AL90850USBAed01-10/2013 Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel- Lucent. All other trademarks are the property of their respective owners. The information

More information

Copyright Autoliv Inc., All Rights Reserved

Copyright Autoliv Inc., All Rights Reserved Technical Description & Installation Guide Model 24 SQ Sensor Version: 1.0 Copyright Autoliv Inc., All Rights Reserved Vervielfältigung oder Weitergabe ohne ausdrückliche, vorherige Genehmigung von Autoliv

More information

1. Constitution of the Unit Assy-Wireless Charging ( WPC ) for vehicle

1. Constitution of the Unit Assy-Wireless Charging ( WPC ) for vehicle USER MANUAL_OKA-200W 1. Constitution of the Unit Assy-Wireless Charging ( WPC ) for vehicle Wireless Charger Unit, it s possible to charge the receiver based upon WPC( Wireless Power Consortium ) Standard.

More information

RFC1000. Wireless Transceiver for the RFOT, Therm A lert and RF2000A data loggers. Product User Guide

RFC1000. Wireless Transceiver for the RFOT, Therm A lert and RF2000A data loggers. Product User Guide RFC1000 Wireless Transceiver for the RFOT, Therm A lert and RF2000A data loggers Product User Guide Product User Guide Table of Contents Product Overview... 3 Software Installation... 4 Activating & Deploying

More information