V88 socket - Spring clamp terminal,

Size: px
Start display at page:

Download "V88 socket - Spring clamp terminal,"

Transcription

1 REVISION V - Spring clamp terminal, Datasheet panel mount pole Features Panel / flush mount Sturdy spring clamp terminals Twin connection per relay contact Suitable for all D and KDN relay series Easy & quick installation (up to % reduction of wiring time) Positive mechanical keying Trifurcated female receiver for tight grip relay pin Clear terminal ID Benefits Description GEN. ± ± ± mm LINEAR ANGLE V HOLES DIMENSIONS IN: FILENAME: SHEET OF SCALE: DRAWN BY: CHECKED: DATE: V : AV -0-0 THIRD ANGLE PROJECTION The V is a panel/flush mount relay. The V has a base PROPERTY OF NIEAF-SMITT BV UTRECHT - THE NETHERLANDS. DISCLOSURE TO THIRD PARTIES OR COPYING/ with two highly reliable spring clamp terminals per relay contact, so REPRODUCTION IN ANY FORM WHATSOEVER, IS NOT PERMITTED WITHOUT THE WRITTEN PERMISSION OF THE OWNER I:\TI\Inventor\Relais\Voeten\V WAGO voet achter\v\v.iam looping/daisy chaining can be done on the an no external connector or terminal is needed. The spring clamp terminal makes a quick connection possible by pressing the spring with a flat-bladed screwdriver and inserting the stripped wire. Solid and (fine) stranded wires up to.mm can be inserted in the spring clamp terminals. This quick & easy wiring method saves up to % wiring time. Pinning on the complies with the pinning on the relay. To prevent fault relay placement the can be equipped with mechanical keying to accept only designated identical keyed relays. DATE NAME SIZE A Proven reliable Long term availability Easy to maintain Low life cycle cost No maintenance Industry compliancy EN Electromechanical control circuit devices and switching elements IEC 0 - Electromechanical elementary relays Clear UP arrow for correct mounting. Application The V relay is suitable for general industrial applications with a space saving design. Installation and replacement of relays is made easy and cost saving. No maintenance is required for the user. Suitable for all D and KDN relay series.

2 V Technical specifications Technical characteristics Contact rating 0 A Dielectric strength IEC 0 / IEC 0, 00 V, 0 Hz, min Protecting category IEC 0, IP0 Mounting Panel mounting Max. ambient temperature 0 C Weight g Dimensions 0 x. x. mm (depth is mm from front of panel) Wire size mm Wire stripping length -0 mm Material Polyamide, 0% glass Socket contacts Spring terminal Max. torque value mounting screws Nm Accessories A0 Key receptacle Connection diagram Bottom

3 REVISIE REVISIE V Technical specifications Dimensions,,, Keying holes, Top,,, R0,,, Top, Bottom Keying holes Top,, Keying holes R0,,, Hole pattern R0, Bottom Bottom Keying holes ALG. LINEAIR HOEK GATEN MAATEENHEID: FILENAAM: BLADEN BLAD SCHAAL: GETEKEND: mm Tek voor datasheet : AV Voor datasheet V Hole pattern Hole pattern EIGENDOM VAN NIEAF-SMITT BV TE UTRECHT. VERMENIGVULDIGING OF MEDEDELING AAN DERDEN, IN WELKE VORM DAN OOK, IS ZONDER SCHRIFTELIJKE TOESTEMMING VAN EIGENARES NIET GEOORLOOFD. I:\TI\Inventor\Relais\Voeten\V WAGO voet achter\v\v.iam GECONTR.: AMERIKAA Top,,,, R0, Bottom ALG. LINEAIR HOEK GATEN MAATEENHEID: FILENAAM: BLADEN BLAD mm Tek voor datasheet Voor datasheet V IN WELKE VORM DAN OOK, IS ZONDER SCHRIFTELIJKE TOESTEMMING VAN EIGENARES NIET GEOORLOOFD. ALG. LINEAIR HOEK GATEN MAATEENHEID: FILENAAM: BLADEN BLAD SCHAAL: GETEKEND: mm Tek voor datasheet : AV DATUM SCHAAL: GETEKEND: GECONTR.: DATUM: Voor : datasheet AV V NAAM AMERIKAANSE PROJECTIE FORMAAT EIGENDOM VAN NIEAF-SMITT BV TE UTRECHT. VERMENIGVULDIGING OF MEDEDELING AAN DERDEN, IN WELKE VORM DAN OOK, IS ZONDER SCHRIFTELIJKE TOESTEMMING VAN EIGENARES NIET GEOORLOOFD. Hole pattern I:\TI\Inventor\Relais\Voeten\V WAGO voet achter\v\v.iam EIGENDOM VAN NIEAF-SMITT BV TE UTRECHT. VERMENIGVULDIGING OF MEDEDELING AAN DERDEN, A GECONTR.: AMERIKAA I:\TI\Inventor\Relais\Voeten\V WAGO voet achter\v\v.iam Dimensions in mm, tolerance + 0. mm,, ALG. LINEAIR HOEK GATEN MAATEENHEID: FILENAAM: BLADEN BLAD mm Tek voor datasheet Voor datasheet V SCHAAL: : GETEKEND: AV DATUM NAAM GECONTR.: DATUM: AMERIKAANSE PROJECTIE FORMAAT A

4 V Technical specifications Tri-furcated female receiver for tight grip relay pin V Spring terminal relay for contact relays (all D-relay series) For details see datasheet V.

5 Positions of placement possible Positions of placement possible Positions of placement possible Positions of placement possible V Keying Mechanical keying relay and (optional) Function: To prevent wrong installation To prevent damage to equipment To prevent unsafe situations Using keyed relays and s prevents a relay being inserted in a wrong. For example it prevents placing a VDC relay in a 0 VDC circuit. Positive discrimination is possible per different funtion, coil voltage, timing, monitoring, safety and non-safety. The D-relays keying option gives x = possibilities. Upon ordering the customer simply indicates the need for the optional keying. Mors Smitt will assign a code to the relay and fix the pins into the relay. The s are supplied with loose key receptacles. Inserting the keys into the is very simple and self explaining. Remark: and relay type are only examples. Top Bottom relay Key receptacle B H D F E 0 S T Z V X Key receptacle keying pin F D G C H B 0 X V Y U Z T keying pin Left Right Left Right A C U B D T V H G E S F Z Example keying position G-Z on Y X W A G Y H Z X F E T V B D C U Example keying position G-Z on relay S W

6 V Technical specifications Installation & inspection Installation Before installation or working on the relay: disconnect the power supply first! Install and connect wiring according to the terminal identification. Plug relay into the ensuring there is no gap between the bottom of relay and the. Reverse installation into the is not possible due to the mechanical blocking snap-lock feature. No external retaining clip needed as the snap-lock will hold the relay into the under all circumstances and mounting directions (according shock & vibration requirements IEC, Category I, Class B, Body mounted). Warning! - To remove relays from the, employ up and down lever movements. Sideway movement may cause damage to the coil wires. When plugging the relay into the, the female trifurcated receivers will automatically cut through the corrosion on the pins and guarantee a reliable connection. Inspection If the does not work after inspection of the correct wiring and relay connection, replace the unit with a similar model. When returning products for investigation, please provide all information on the RMA form. Send defective products back to the manufacturer for repair or replacement. Normal wear and tear or external causes are excluded from warranty.

7 V Ordering possibilities V V A0 Article nr Code Description 0000 V Spring terminal relay for contact relays 0000 V Spring terminal relay 000 A0 Key receptacle

8 DS-V Ind V.0 Feb 0 Mors Smitt France SAS Tour Rosny, Avenue du Général de Gaulle, F - Rosny-sous-Bois Cedex, France T + (0) 0, F + (0) 00 E sales@msrelais.com Mors Smitt Asia Ltd. # 0, Billion Trade Centre, Hung To Road Kwun Tong, Kowloon, Hong Kong T +, F + E info@morssmitt.hk Mors Smitt B.V. Vrieslantlaan, AA Utrecht, Netherlands T + (0)0, F + (0)0 E sales@nieaf-smitt.nl Mors Smitt Technologies inc. 0 Sackett Point Road North Haven, Ct 0, USA T + (0), F + () E mstechnologies@msrelais.com Mors Smitt UK Ltd Doulton Road, Cradley Heath West Midlands, B QB, UK T + (0), F + (0) 0 E info@morssmitt.co.uk (c) Copyright 0 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.

UB 001 relay - 1 level load shedding

UB 001 relay - 1 level load shedding - 1 level load shedding Datasheet Features Load shedding relay 1 voltage level 1 N/O solid state contact Plug-in design with secure locking feature for maximum ease of maintenance -40 C...+85 C operating

More information

UB 200 relay - Voltage monitoring

UB 200 relay - Voltage monitoring - Voltage monitoring Datasheet Features Voltage monitoring relay 1 voltage level 2 C/O contacts, form Z Plug-in design with secure locking feature for maximum ease of maintenance -40 C...+85 C operating

More information

UTC relay - Voltage monitoring & off delay

UTC relay - Voltage monitoring & off delay - Voltage monitoring & off delay Datasheet Features Voltage control time delay relay Total time delay range from 4 min to 6 min, fixed in factory 1 N/O solide state contact, 3 A Plug-in design with secure

More information

UBC 200 relay - Voltage monitoring

UBC 200 relay - Voltage monitoring - Voltage monitoring Datasheet Features Voltage monitoring relay 1 voltage level 2 C/O contacts, form C Plug-in design with secure locking feature for maximum ease of maintenance -40 C...+85 C operating

More information

MSV200 - Hall effect transducer

MSV200 - Hall effect transducer - Hall effect transducer Datasheet Features Specially designed for railway applications Closed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault

More information

TELAU 400 relay - Delay-on pull-in or

TELAU 400 relay - Delay-on pull-in or - Delay-on pull-in or Datasheet drop-out, 4 C/O Features Delay on pull-in or on drop-out relay Delay range 0.2 h...2 h Time delay fully programmable by dip switch Status LED indicator Plug-in design with

More information

407 relay - Latching, safety critical, 40 contacts Datasheet

407 relay - Latching, safety critical, 40 contacts Datasheet - Latching, safety critical, 40 contacts Datasheet Features Latching relay using separate coils and magnetic rocker mechanism Plug-in design with secure locking feature for maximum ease of maintenance

More information

MSA Hall effect transducer

MSA Hall effect transducer - Hall effect transducer Datasheet Features Specially designed for railway applications losed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault

More information

MSA500 - Hall effect transducer

MSA500 - Hall effect transducer - Hall effect transducer Datasheet Features Specially designed for railway applications losed loop (compensated) High dielectric strength Precise linearity Precise accuracy High dynamic response No foucault

More information

BD relay - Industrial latching power

BD relay - Industrial latching power BD relay - Industrial latching power Datasheet relay, 4 pole Features Latching (bistable) relay Compact plug-in design 2 combined coils 3 C/O contacts and N/C contact Flat, square silver plated relay pins

More information

RC-19A relay - Current monitoring

RC-19A relay - Current monitoring - Current monitoring Datasheet Features AC current monitoring relay Compact design 1 C/O contact Easy installation High continuous overcurrent possible Protection against short circuit and low impedance

More information

BM 400 relay - Mixed load, 4 contacts

BM 400 relay - Mixed load, 4 contacts - Mixed load, 4 contacts Datasheet Features Instantaneous relay Plug-in design with secure locking feature for maximum ease of maintenance double make / double break C/O silver contacts (form Z) gold bifurcated

More information

D4-U200 relay module - 4-pole

D4-U200 relay module - 4-pole D4-U200 relay module - 4-pole Datasheet Features Ultra compact space saving 4-pole relay module Easy replacement of 4-pole contactors Module consists of 4-pole relay and housing Various contact combinations

More information

KCS-U200 relay - Latching, 2 pole

KCS-U200 relay - Latching, 2 pole - Latching, 2 pole Datasheet Features Latching (bistable) relay Compact design 2 C/O contacts 2 galvanic isolated coils Weld-no-transfer contacts Flash barrier 2.8 x 0.8 faston connections Transparent

More information

TTBCR 200 relay - Delay-on drop-out,

TTBCR 200 relay - Delay-on drop-out, - Delay-on drop-out, Datasheet instantaneous Features Delay-on drop-out and instantaneous functions Delay range from 0.5 s up to 4 s (other up to 60 s on request) Time delay fully programmable by dip switch

More information

AG 400 relay - Gold plated, 4 contacts

AG 400 relay - Gold plated, 4 contacts - Gold plated, 4 contacts Datasheet Features Instantaneous relay Plug-in design with secure locking feature for maximum ease of maintenance 4 double make / double break C/O contacts (form Z), gold plated

More information

TDB4-U200 relay - Timer, delay-on, 4 pole

TDB4-U200 relay - Timer, delay-on, 4 pole - Timer, delay-on, 4 pole Datasheet Features Time delay relay, delay on pull-in Compact plug-in design 4 C/O contacts Delay time adjustable with a lockable knob Also available with fixed time delay Magnetic

More information

MTDV4-U200 relay - Voltage monitoring,

MTDV4-U200 relay - Voltage monitoring, - Voltage monitoring, Datasheet timer delay-on /-off, 4 pole Features Description Plug-in electronic voltage monitoring relay with optional delay-on and delay-off timer function and four change-over contacts.

More information

TBSBAO 400 relay - Delay-on pull-in,

TBSBAO 400 relay - Delay-on pull-in, - Delay-on pull-in, Datasheet 4 C/O Features Delay-on pull-in Delay range 50 ms...0 s Time delay fully programmable by dip switch Status LED indicator Plug-in design with secure locking feature for maximum

More information

MTDV4 relay - Voltage monitoring,

MTDV4 relay - Voltage monitoring, - Voltage monitoring, Datasheet timer delay-on /-off, 4 pole Features Description Plug-in electronic voltage monitoring relay with optional delay-on and delay-off timer function and four change-over contacts.

More information

Mors Smitt Industrial Technology. High performance plug-in relays

Mors Smitt Industrial Technology. High performance plug-in relays Mors Smitt Industrial Technology High performance plug-in relays Power generation and distribution operators across the world rely on our relays Product range D-relays series The unique plug-in D-relay

More information

C relay - Safety critical, 9 contacts

C relay - Safety critical, 9 contacts - Safety critical, 9 contacts Datasheet Features Instantaneous relay Ultra compact package size Safety-critical relay Plug-in design with secure locking feature for maximum ease of maintenance 9 double

More information

Manual Signal calibration box (SCB)

Manual Signal calibration box (SCB) Manual Signal calibration box (SCB) Features 35 mm rail mounting Pluggable screw connections 1 signal input 10 indicator outputs 1 NMEA0183 compatible output USB connection Scaling with Windows TM based

More information

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors

Mors Smitt Industrial Technology. Industrial current & voltage sensors. Hall effect current & voltage sensors Mors Smitt Industrial Technology Industrial current & voltage sensors Hall effect current & voltage sensors Mors Smitt Industrial Technology Industrial sensors Industrial current & voltage sensors Closed

More information

CK relay - safety critical, 9 contacts

CK relay - safety critical, 9 contacts - safety critical, 9 contacts Datasheet Features Instantaneous relay Safety critical relay Weld resistant Weld no transfer safety contacts standard Plug-in design with secure locking feature 9 double break

More information

D-B Power relay, high DC breaking capacity Part of D-platform

D-B Power relay, high DC breaking capacity Part of D-platform /// Plug-in industrial relay with 4 C/O contacts Rugged plug-in relays for extreme reliability, within long endurance applications and harsh environments D-B Power relay, high DC breaking capacity Part

More information

CM relay - 7 contacts + 2 gold contacts

CM relay - 7 contacts + 2 gold contacts - 7 contacts + 2 gold contacts Datasheet Features Instantaneous relay For combined power & dry circuit applications in diesel locomotives 4 N/C + 5 N/O double break contacts with N/C & N/O gold bifurcated

More information

D-U200 Instantaneous relay Part of D-platform

D-U200 Instantaneous relay Part of D-platform /// Plug-in railway relay with 4 C/O contacts Rugged plug-in relays for extreme reliability, within long endurance applications and harsh environments Part of D-platform Description Features Instantaneous

More information

D Instantaneous relay Part of D-platform

D Instantaneous relay Part of D-platform /// Plug-in industrial relay with 4 C/O contacts Rugged plug-in relays for extreme reliability, within long endurance applications and harsh environments D Part of D-platform Features Instantaneous compact

More information

Mors Smitt Industrial Technology

Mors Smitt Industrial Technology Mors Smitt Industrial Technology Mors Smitt Industrial Technology Mission statement To take a leading role in industrial relay technology, installation instruments and controls and marine bridge instrumentation.

More information

Mors Smitt Industrial Technology

Mors Smitt Industrial Technology Mors Smitt Industrial Technology Mors Smitt Industrial Technology Designers, manufacturers & sup instrumentation and electronic con for de Industry Heavy duty relays General purpose relays Time delay

More information

Portable relay tester PRT-MS1 User manual

Portable relay tester PRT-MS1 User manual Portable relay tester PRT-MS1 User manual www.morssmitt.com Mors Smitt B.V. Vrieslantlaan 6 3526 AA Utrecht The Netherlands Note: The performance of an electromechanical relay depends on several external

More information

Mors Smitt Group - Serving Safety

Mors Smitt Group - Serving Safety Mors Smitt Group Mors Smitt Group - Serving Safety Mors Smitt France SAS Mors Smitt B.V. Mors Smitt UK Ltd. Mors Smitt Technologies Inc. Mors Smitt Asia Ltd. Zhongshan Mors Smitt Relay Ltd. Mors Smitt

More information

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5) 46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance

More information

MI-10kV. Technical specifications Operating instructions. Supplier:

MI-10kV. Technical specifications Operating instructions. Supplier: Technical specifications Operating instructions Supplier: Nieaf-Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht P.O. Box 7023, 3502 KA Utrecht The Netherlands T +31 30 288 1311 F +31 30 289 8816 E sales@nieaf-smitt.nl

More information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features: RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16

More information

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc. User s Guide RP5600 Passive Probe July 2010 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark

More information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information Latching Relay CSM DS_E Compact Mechanical Lock Latching Relays with Manual Buttons Compact design with a height of 7 mm, width of. mm, and depth of 8. mm. Plus, one Relay only weighs 7 g. Quick set and

More information

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30 Handleiding / Manual INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Clamp Multimeter from its packing, you should

More information

Screw Hole. Figure 1 TOOLING ASSISTANCE CENTER PRODUCT INFORMATION

Screw Hole. Figure 1 TOOLING ASSISTANCE CENTER PRODUCT INFORMATION Application Specification Solderless Light Emitting Diode (LED) 114-32038 Socket (Type LK) 07 SEP 12 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions

More information

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808 Instruction Manual Manual de instrucciones Guide d utilisation ET2025 PMET2025-8 Rev 808 www.arrowfastener.com GENERAL SAFETY RULES WARNING! Read all instructions. Failure to follow all instructions listed

More information

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy

More information

2 or 4 pole changeover contact Plug-in/Faston 187

2 or 4 pole changeover contact Plug-in/Faston 187 56 Miniature power relays 56 Plug-in - Power relay, & 4 pole Flange mount option - (Faston 87, 4.8 x 0.5 mm termination) C coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free

More information

Precipitation Monitor ,

Precipitation Monitor , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

High Current Pin and Socket Contacts 31 JUL 13 Rev C

High Current Pin and Socket Contacts 31 JUL 13 Rev C Application Specification High Current Pin and Socket Contacts 31 JUL 13 NOTE NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

48 Series - Relay interface modules A. Features

48 Series - Relay interface modules A. Features Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive

More information

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Data Sheet 10/86-2.36-EN All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Compact robust power relay Type RH(M) 1003: 3 changeover contacts Type RH(M) 1004: 4

More information

Aluminum Electrolytic Capacitors Axial High Temperature, High Ripple Current

Aluminum Electrolytic Capacitors Axial High Temperature, High Ripple Current Aluminum Electrolytic Capacitors Axial High Temperature, High Ripple Current smaller 9 AHT-DIN 8 AHT lower dimensions higher ripple Fig. 25 C 38 AML QUICK REFERENCE DATA DESCRIPTION VALUE Nominal case

More information

62 Series - Power relays 16 A. Features / /

62 Series - Power relays 16 A. Features / / 6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GG507S / / 2013 Original operating instructions Fail-safe inductive sensor GG507S 80005283 / 00 05 / 2013 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...4 2.1 Safety-related requirements

More information

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

PARM-SIZED, 16-CHANNEL RELAY TERMINALS Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Low profile PCB relays 8-12 - 16 41 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 (3.5 mm pin pitch) 41.52-2 Pole 8 (5 mm pin pitch) 41.61-1 Pole 16 (5 mm pin pitch) PCB mount - direct or

More information

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi 34 Series - Slim electromechanical PCB relays 6 A Features 34.51 Ultra-slim 1 Pole - 6 A relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw or screwless sockets 1 Pole

More information

Brochure. SNK series Terminal blocks Screw technology

Brochure. SNK series Terminal blocks Screw technology Brochure SNK series Terminal blocks Screw technology SNK series Terminal blocks Screw technology Rely on our expertise ABB screw clamp technology benefits from years of experience. Billions of our screw

More information

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions & MAX SETTINGS, DRY CONTACT Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING

More information

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,

More information

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety

More information

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model Relays with Forcibly Guided Contacts CSM DS_E_6_ Compact, Slim Relays Conforming to EN Standards Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery

More information

Precipition Sensor with analogue Intensity Output ,

Precipition Sensor with analogue Intensity Output , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021335/11/09 Precipition Sensor with analogue Intensity Output 5.4103.20.041, 5.4103.20.741 ADOLF THIES

More information

62.22 Copper side view

62.22 Copper side view 62 Power relays 16 62 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced insulation between coil and contacts according to EN 60335-1,

More information

Distributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility

More information

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1 Slim Relays with Forcibly Guided Contacts Conforming to EN Standards EN50205 Class A, approved by VDE. Ideal for use in safety circuits in production machinery. Four-pole and six-pole Relays are available.

More information

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay 62 Series - Power relays 16 62 SERIES Features 62.22 / 62.23 62.22-0300 / 62.23-0300 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced

More information

Palm-sized, 16-channel Relay Terminals

Palm-sized, 16-channel Relay Terminals Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive

More information

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN

More information

Relay interface modules A

Relay interface modules A 4C SЕRIES Relay interface modules 8-10 - 16 A Escalators Road / tunnel lighting Hoists and cranes Carousel warehouses Control panels Panels for electrical distribution FINDER reserves the right to alter

More information

Single Arm Pole Mount. Installation Manual Edition v1.01. For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN

Single Arm Pole Mount. Installation Manual Edition v1.01. For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN Pole Mount Installation Manual 2016 Edition v1.01 For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN Table of Contents 1 1 2 3 4 5 5 Introduction Customer Support Project Essentials Assembly: Steps

More information

38 Series - Relay Interface Modules A

38 Series - Relay Interface Modules A Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay

More information

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R 170.ADD.LFS.RB0 0,8.011-98/B r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R INDEX ASSEMBLING... 1 Warning... 1 General assembling information... 1 Wall mounting... 1 Omega din rail mounting... 2 MECHANICAL

More information

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC Relays with Forcibly Guided Contacts G7S CSM_G7S_DS_E_5_ Relays Conforming to EN Standard Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays .4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................

More information

5.5 SLG 75. Read/Write Devices Read/Write Antennas

5.5 SLG 75. Read/Write Devices Read/Write Antennas 5.5 SLG 75 Application area SLG 75 The SLG 75 ANT is a read/write device in the middle of the performance range. It can only be used with ANT 1, ANT 12, ANT 18 and ANT 30. The antennas can be very easily

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set WALTER MEIER (Manufacturing) Inc. 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-708482 Ph.: 800-274-6848 Revision C2 02/2013

More information

Zelio Plug-In Relays. RXG interface relays. Catalog

Zelio Plug-In Relays. RXG interface relays. Catalog Zelio Plug-In Relays Catalog 204 Contents Zelio Plug-In Relays bbintroduction.... 3 bbspecifications.................................................... 4 bbreferences... 7 bbdimensions.... 0 bbwiring

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

Operating Instructions and Parts Manual Folding Hydraulic Crane Model: JFHC-200X

Operating Instructions and Parts Manual Folding Hydraulic Crane Model: JFHC-200X This Manual is Bookmarked Operating Instructions and Parts Manual Folding Hydraulic Crane Model: JFHC-200X WMH TOOL GROUP 2420 Vantage Drive Elgin, Illinois 60123 Part No. M-106206K Ph.: 800-274-6848 Revision

More information

1-830 SERIES DISPLACEMENT TRANSMITTER

1-830 SERIES DISPLACEMENT TRANSMITTER 1-830 SERIES DISPLACEMENT TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com

More information

Sensor technologies Proximity sensors Series ST9. Brochure

Sensor technologies Proximity sensors Series ST9. Brochure Sensor technologies Proximity sensors Series ST9 Brochure 2 Sensor technologies Proximity sensors Series ST9 9 mm groove with cable without wire end ferrule, tin-plated, 2-pin, without wire end ferrule,

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

Liquid level monitoring relay CM-ENS.2x

Liquid level monitoring relay CM-ENS.2x Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

SOLISTRAND* Crimping Dies

SOLISTRAND* Crimping Dies SOLISTRAND* Crimping Dies Instruction Sheet (Used in Crimping Heads 08-697 69097 and 69099) 5 APR Terminals Butt Splices Parallel Splices = Wire Barrel DIE SET NUMBERS FOR DIE SET CRIMPING HEAD 69097 NUMBERS

More information

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC Relays with Forcibly Guided Contacts G7S-@-E CSM_G7S-_-E_DS_E_3_ Lineup Now Includes -A Models Relays with forcibly guided contacts (EN525 Class A, certified by VDE). Supports the CE marking of machinery

More information

GENERAL PURPOSE RELAYS

GENERAL PURPOSE RELAYS CONTROL LOGIC GENERAL PURPOSE RELAYS GR c3controls offers a full line of General Purpose Relays ( plug-in relays), perfect for your control logic applications. Quick and economical to install, our relays

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1 Features 7S.12...5110 7S.14...0220/0310 7S.16..0420 Relay module with forcibly guided contacts 7S.12 with 2 pole (1NO + 1 NC) 7S.14 with 4 pole (2 NO + 2 NC and 3 NO + 1 NC) 7S.16 with 6 pole (4 NO + 2

More information

Magnum low voltage drawout circuit breaker IEC horizontal stab cassette shutter kit (double wide A cassettes)

Magnum low voltage drawout circuit breaker IEC horizontal stab cassette shutter kit (double wide A cassettes) kit (double wide 4000 6300A cassettes) i WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON THE EQUIPMENT. (2) ALWAYS DE-ENERGIZE PRIMARY AND SECONDARY CIRCUITS IF A CIRCUIT

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

CSM_G7S-_-E_DS_E_7_1

CSM_G7S-_-E_DS_E_7_1 Relays with Forcibly Guided Contacts G7S-@-E CSM_G7S-_-E_DS_E_7_ Relays with Forcibly Guided Contacts and High Switching Capacity of A Relays with forcibly guided contacts (EN525 Class A, certified by

More information

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER Installation & User Guide For Powering Distributed Audio Systems TWO CHANNEL AMPLIFIER A45-X2 A45-X2 TWO CHANNEL AMPLIFIER TABLE OF CONTENTS Features...1 Product Overview...2 Package Contents...4 Preparing

More information

38 Series - Relay interface modules A. Features /

38 Series - Relay interface modules A. Features / Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions

More information

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document USER MANUAL Maxwell Technologies Ultracapacitor Energy Storage Modules Models: BMOD0058 E016 B02 BMOD0006 E160 B02 Document 3000200.1 Notice: The products described herein are covered by one or more of

More information

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4 58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals

More information