Vitocontrol-C, Ecotronic KRT PN:

Size: px
Start display at page:

Download "Vitocontrol-C, Ecotronic KRT PN:"

Transcription

1 70 McMurray Road, Waterloo, Ontario NV G Vitocontrol-C, Ecotronic KRT 0-00 PN: 70 Project Project No. : : PRJ-000 Technical data Power supply Main fuse Dimensions Degree of protection : : : : 0V, 60Hz, ph L,L,L/N/G A 000 x 00 x 00 mm IP6, NEMA type Preliminary remarks: Retighten all wire holding screws inside the control before start-up. Provide fuseable disconnect means according to local code. Field modifications of control manufactured by K-W Electronic Service Inc. and / or Viessmann Mfg. Inc. will void factory CSA certification! If modifications are performed, electrical safety field inspection is required according to local codes. K-W Electronic Service Inc. and are not responsible for any damage, injury or loss of life resolting from field modifications. Attention: This is not complete system drawing. The installer has the responsibility to assure that the control is suitable for the respective installation, and all necessary safety equipment is installed. Attention: The information about wire type, wire number and wire gauge, made in the wiring diagrams is not obligatory. The final decision of these settings has to be done by the executing installation company considering the local codes and regulations. Prepared Control approved :.0. : - by by PD - Number of pages: LR 07 Designed and manufactured by K-W Electronic Service Inc.

2 0 Previous page: Next page:. Table of contents Page Page type.0. :.0. Page description Title page / cover sheet Title page Table of contents Table of contents : - 0. Table of contents Table of contents : 0-0 Parts list Parts list : IDE.PS = 0W - KOB.Ecotronic BMK600.D.0. Panel layout Panel layout.0. Schematic multi-line Power.0. 6 Schematic multi-line KSK and ZPK supply system.0. 7 Schematic multi-line Safety chain evaluation.0.0 Schematic multi-line De-ashing auger M De-ashing ascending conveyor auger M.0. Schematic multi-line Boiler pump.0. 0 Schematic multi-line Error report.0. Schematic multi-line Loader module M External loader system T.0. Schematic multi-line Spring-operated extraction system T.0. Schematic multi-line Exhaust fan.0. Schematic multi-line CAN plug.0. 6 Schematic multi-line Light barrier- embers B.0. 7 Schematic multi-line Light barrier- embers B.0. Schematic multi-line Light barrier- de-ashing system B.0. Schematic multi-line Water level safety switch N.0. 0 Schematic multi-line Secondary airflow valve M.0. Schematic multi-line Primary airflow valve M0.0. Schematic multi-line Sensors.0. Schematic multi-line Lambda sensor B6 Slide valve T0.0. Schematic multi-line Ignition blower.0. Schematic multi-line Spare output.0. 6 Schematic multi-line Boiler valve.0. 7 Schematic multi-line Grate drive M.0. Schematic multi-line Rotation blower M.0. Schematic multi-line Solenoid valves (pneumatic cleaning system).0. 0 Schematic multi-line Combustion chamber door safety.0. 0 Cable overview Cable overview : W - W Cable overview Cable overview : W - W.0. Terminal diagram Terminal diagram : X.0.. Terminal diagram Terminal diagram : X Terminal diagram Terminal diagram : X Terminal diagram Terminal diagram : X.0. 6 Terminal diagram Terminal diagram : X Graphic Schematic diagram.0. 0 Graphic Arragement of electrical wiring McMurray Road, Waterloo, Ontario NV G Table of contents : Revision PRJ-000 F06_00 0

3 0 Table of contents Page Page type Page description 0 Graphic Boiler lay-out.0. 0 Graphic Overview of loader system.0.0 Revision.0. F06_00 Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Table of contents : 0-0 PRJ

4 0 Parts list VI_F0_00 Device tag Quantity Designation Type / Model Producer Order No. -A Power supply VDC 0W PSR-SF Idec D Diode 00V A N00-T Diode Inc D Diode 00V A N00-T Diode Inc F Fuse A/600V class J AJT Ferraz 00-6F Fuse 6.A/0V time delay GDL6-/ Ferraz 00-6F0 Circuit breaker pole A H- (0000) Weidmüller 60 -F Motor circuit controller.6-.a KTA7-S-.A Sprecher & Schuh 60 -F Auxiliary contact NO KT7-PE-0 Sprecher & Schuh 606 -F Terminal adapter KT7-0TE Sprecher & Schuh 606 -F Motor circuit controller.-a KTA7-S-A Sprecher & Schuh 600 -F Auxiliary contact NO KT7-PE-0 Sprecher & Schuh 606 -F Terminal adapter KT7-0TE Sprecher & Schuh 606 -F0 Motor circuit controller -.6A KTA7-S-.6A Sprecher & Schuh 60 -F0 Auxiliary contact NO KT7-PE-0 Sprecher & Schuh 606 -F0 Terminal adapter KT7-0TE Sprecher & Schuh 606 -F Circuit breaker -pole 0A H-0 (0000) Weidmüller 60 -F Circuit breaker -pole 0A H-0 (0000) Weidmüller 60 -F Circuit breaker pole 0A H-0 (70000) Weidmüller 60 -F Fuse 0.A/0V time delay GDL/ Ferraz 0-6F Fuse 0.A/0V time delay GDL/ Ferraz 0 -FU Variable frequency drive 0.7kW 0V EEV7KC LENZE 6 -FU Function module EZAFCC00 LENZE 67 -H Panel light VDC,.W LFB-CS-THWW Idec 000-6K Contactor A 0VAC CGC-A-0 Carlo Gavazzi 600-6K Relay DPDT 0VAC RJS-C-A0 Idec 006-7K Contactor A VDC CGMS-D-S-0 Carlo Gavazzi K Contactor A VDC CGMS-D-S-0 Carlo Gavazzi K Contactor A 0VAC CGMS-A-0-0 Carlo Gavazzi 600 -K Contactor A 0VAC CGMS-A-0-0 Carlo Gavazzi 600 -K0 Contactor A 0VAC CGMS-A-0 Carlo Gavazzi 600-0K0 Relay SPDT 0VAC RJS-C-A0 Idec 00 -K Contactor A 0VAC CGC-A-0 Carlo Gavazzi K Contactor A 0VAC CGC-A-0 Carlo Gavazzi K Relay SPDT 0VAC RJS-C-A0 Idec 00-6K Relay SPDT 0VAC RJS-C-A0 Idec 00 -K Contactor A 0VAC CGMS-A-0-0 Carlo Gavazzi 600 -Q Disconnect -pole 60A KG 6B K&N 606 -Q Motor circuit controller -.6A KTA7-S-.6A Sprecher & Schuh 60 -Q Terminal adapter KT7-0TE Sprecher & Schuh 606 -R Resistor 0 ohm 0.W ERD-STJ0V Panasonic 6 -S Door switch 7000 RITTAL 606 -T Transformator 0-./V A NTKC (060I0) Schnidbauer T Transformer 0-V 0VA class SA-0 White Rodgers 0-6U Main board KSK Köb 76-6U Slave board ZPK Köb 6 -U Soft starter E7MM0-A00 LENZE 60 -U Function module EZAFCC00 LENZE 67 -U Soft starter E7MM0-A00 LENZE 60 -U Function module EZAFCC00 LENZE 67 -U Control module BMK600.D Köb 7667 Previous page:. Next page:.0. : McMurray Road, Waterloo, Ontario NV G Parts list : IDE.PS = 0W - KOB.Ecotronic BMK600.D PRJ-000 0

5 0 Wire duct -F -6F0-6F -F -F -F -6F -F -F -F -F0 -Q -6K -6K -0K0-6K -6T Wire duct -6K -7K -K -K -K0 -K -K -K -7K -T Wire duct -6U KSK -A Wire duct Wire duct -U Wire duct -U Wire duct Wire duct -FU Wire duct -6U ZPK Wire duct Wire duct Wire duct -X -X -X -X.GND Previous page: Next page: Components changed.0. : McMurray Road, Waterloo, Ontario NV G Panel layout PRJ-000 0

6 0 L / 6.0 L / 6.0 L / 6.0 -F A class J L0 / 6.0 -Q 60A Power On/Off T L T L T L -A PSR-SF VDC, 0W Power supply L N V+ / 6. V- / 6. -S Door switch N-bus -H Panel light N / 6.0 -X N GND -W T0 xawg 0VAC -U Power supply 0V, 60Hz, ph WH GN L L L N G Terminals designation -X = Line voltage connections -X = V connections -X = Dry contact outputs Previous page: Next page: 6 : McMurray Road, Waterloo, Ontario NV G Power PRJ-000 0

7 0. / L L /.0. / L L /.0. / L L /.0-6F 6.A -6F0 A L /.. / V+. / V- V+ /.7 V- /.7. / L0-6U KSK Main board L /. -6U ZPK Slave board X7: pins X: X: 6 X6: X6: X6: X60: X6: CCD. / 0. CCD. / 0.. / N N-bus -6K CGC-A 0VAC -X GND N GND 0 GND A A NO NC... -6K RJ 0VAC NO NC N /.6-6W T0 xawg 0VAC -6W T0 xawg :GN 0VAC -6W T0 xawg :WH :GN 0VAC :GN -6N 0C Safety temp. limiter (STL) Contact opens on temp, rise. Θ -6N Watts OEM 0 Low water cut-off L L P P A -6N Water safety pressure switch P Previous page: Next page: 7 : McMurray Road, Waterloo, Ontario NV G KSK and ZPK supply system PRJ

8 0 7. / L+ L+ / 7.0-6K 6. 6 SK0 /. SK0 /. SK /. SK /. -7K CA7--0 VDC A A -7K CA7--0 VDC A A 7. / L- L- / 7.0 NO NC... NO NC... Previous page: 6 Next page: Add -7K.0. : McMurray Road, Waterloo, Ontario NV G Safety chain evaluation PRJ

9 0 6. / L 6. / L 6. / L L /.0 L /.0 L /.0 -F KTA7.6-.A I> I> I> 6 -F KTA7.-A I> I> I> 6 -K.7 6 -K. 6-6U 6. KSK X: -X GND GND 0 -K CGMS-A 0VAC A A NO NC... -K CGMS-A 0VAC 6. / N N / 0. A A NO NC... -W T0 6xAWG 0VAC/0VAC -W T0 6xAWG :GN 6 0VAC/0VAC :GN 6 -M Lenze 0V,.7A,0.7kW,ph De-ashing auger U V W M ~ PE Thermal fuse (Klixon) -M Lenze 0V,.A,0.7kW,ph De-ashing ascending conveyor auger U V W M ~ PE Thermal fuse (Klixon) Previous page: 7 Next page: : McMurray Road, Waterloo, Ontario NV G De-ashing auger M De-ashing ascending conveyor auger M PRJ-000 0

10 0. / L L /.0. / L L /.0. / L L /.0 -F0 KTA7 -.6A I> I> I> 6 -K U 6. KSK -X7: -X GND -K0 CGMS-A 0VAC A A NO NC... -W T0 xawg 0VAC GN -M0 UPS0-0F 0V,.A,0.kW,ph Boiler pump L L L M ~ GND Previous page: Next page: 0 : McMurray Road, Waterloo, Ontario NV G Boiler pump PRJ-000 0

11 0-0K U 6. KSK X6: -0K0 RJ 0VAC. / N N /.0 NO NC 0. -0W T0 xawg 0V max. -X Spare Field power supply 0V, A max. Alarm Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Error report PRJ

12 0. / L. / L. / L L /.0 L /.0 L /.0 -F 0A -7K 7. 6 CAN /. 6. / V+ 6. / V- V+ /.7 V- /.7 -R 0R 0.W BK RD Shield -U Lenze E7MM0-A00 Soft starter L L L PE Lo 7 Hi 7 Lo 7 Hi 7 7 U V W PE T T E E A E 7 A 7 E 7. / SK 7. / SK0 -D 00V A A. E. 7. -W T0 xawg 0VAC -X 6 GND -X W xawg :GN V -W xawg V Spare -W xawg -W6 BN BU xawg BN BU BK -M Lenze 0V,.A,.0kW,ph Loader module motor U V W M ~ PE Thermal fuse (Klixon) S. Limit switch for maintenance cover -B. Wenglor S0S76 Light barrier metering container transmitter -B. Wenglor E0VBS770 Light barrier metering container receiver Previous page: 0 Next page: : McMurray Road, Waterloo, Ontario NV G Loader module M External loader system T PRJ-000 0

13 0. / L. / L. / L 0VAC, ph L /.0 L /.0 L /.0 -F 0A -7K / CAN CAN /.. / V+. / V- V+ /. V- /. Shield RD BK Shield RD BK -U Lenze E7MM0-A00 Soft starter L L L PE Lo 7 Hi 7 Lo 7 Hi 7 7 U V W PE T T E A E 7 E 7. / SK 7. / SK0 -D 00V A -X 6 7 GND -X -W T0 xawg 0VAC -W xawg :GN V -W xawg V -W xawg V -M 0V,.6A,.kWkW,ph Spring-operated extraction system U V W M ~ PE Thermal fuse (Klixon) -S. Limit switch for maintenance cover -S. Limit switch for silo door Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Spring-operated extraction system T PRJ-000 0

14 0. / L. / L. / L L / 6. L / 6. L / 6. -F 0A. / CAN CAN /. -6K 6.6 Shield RD BK Shield RD BK -FU 0.7kW Lenze 00 vector Lo 7 Hi 7 Lo 7 Hi 7 L N PE 7 0 U V W PE T T -X -W LF00S shielded xawg 0VAC :GN -W xawg sh V -M 0V,0A,0.kW,ph Exhaust fan motor U V W M ~ PE Thermal fuse (Klixon) Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Exhaust fan PRJ-000 0

15 0. / CAN Shield RD BK -6U 6. KSK -X6: 6 -X -U Ecotronic -X -T NTKC 0-./V A CAN MMC RS -X: 6 WH screen BN BU OG BKYE RDGN CAN Previous page: Next page: 6 : McMurray Road, Waterloo, Ontario NV G CAN plug PRJ-000 0

16 0-6U 6. ZPK -X -X -6W xawg -6W BN BU xawg BN BU BK -6B. Wenglor S0S76 transmitter -6B. Wenglor E0VBS770 receiver Previous page: Next page: 7 : McMurray Road, Waterloo, Ontario NV G Light barrier- embers B PRJ

17 0-6U 6. ZPK -X -X -7W xawg -7W BN BU xawg BN BU BK -7B. Wenglor S0S76 transmitter -7B. Wenglor E0VBS770 receiver Previous page: 6 Next page: : McMurray Road, Waterloo, Ontario NV G Light barrier- embers B PRJ

18 0-6U 6. ZPK -X -X6 -W xawg -W BN BU xawg BN BU BK -B. Wenglor S0S76 transmitter -B. Wenglor E0VBS770 receiver Previous page: 7 Next page: : McMurray Road, Waterloo, Ontario NV G Light barrier- de-ashing system B PRJ-000 0

19 0-6U 6. ZPK -X7: -X: -X: -X0: -X: -X7 Connection box -W xawg V -W xawg V -N Berstein Water level Previous page: safety switch Next page: 0 : McMurray Road, Waterloo, Ontario NV G Water level safety switch N PRJ-000 0

20 0-6U 6. KSK -X 6 -X 6-0W 6xAWG V BK BN OG WH RD GN -0M Koeb V Secondary airflow valve M Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Secondary airflow valve M PRJ

21 0-6U 6. KSK -X 6 -X 6 -W 6xAWG V BK BN OG WH RD GN -M0 Koeb V Primary airflow valve M Previous page: 0 Next page: : McMurray Road, Waterloo, Ontario NV G Primary airflow valve M0 PRJ-000 0

22 0-6U 6. KSK -X7: -X: -X: -X0: -X: -X7 Connection Box -W xawg GND GND GND -W xawg -W xawg -W xawg -X0 -X0. -X.0 -W xawg -X0 Connection Box Previous page: Next page: Θ -B. Storage tank sensor Top Θ -B. Storage tank sensor Middle Θ -B. Storage tank sensor Bottom :.0. Θ -B0 Boiler supply sensor Θ -B0. Boiler return sensor Θ -B Exhaust gas sensor 70 McMurray Road, Waterloo, Ontario NV G Sensors Θ -B0 Loader module sensor PRJ-000 0

23 0. / V+. / V- -6U 6. KSK -X: -X6:. A. E.6 7 -X -U6 -W xawg WH WH BK GN -T0 Connection box -W xawg VDC -X L N -X -X L N -X6 -X L N -X6 -B6 Lambda sensor WH WH BK GN -M0. Belimo AF-S VDC, W Sluice valve S S S S S S6 M -M0. Belimo AF-S VDC, W Sluice valve S S S S S S6 M Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Lambda sensor B6 Slide valve T0 PRJ-000 0

24 0 6. / L 6. / L -6U 6. KSK -K. -K. -X6: -K CGC-A 0VAC A A NO NC..6 -K CGC-A 0VAC 0. / N N / 6.0 A A NO NC.6.7 -F 0.A -X 7 -X6 Connection Box -W T0 xawg 0VAC -W Module cable 0VAC BK BN BU -M6 HERTZ-Leister 0V,7A,.6kW,ph Ignition blower M ~ Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Ignition blower PRJ-000 0

25 0-6U 6. KSK -X60: -X: N-bus -X 0 N GND Free Previous page: Next page: 6 : McMurray Road, Waterloo, Ontario NV G Spare output PRJ-000 0

26 0. / L. / L. / L L /. L /. -6F 0.A -6T -6U 6. KSK 0VA -X: -6K 6. -6K 6. -6K RJ 0VAC -6K RJ 0VAC. / N N /.0 NO NC NO NC X 0-6W xawg VAC -6Y0 VAC, W Mixing valve actuator OPEN COM. CLOSE Previous page: Next page: 7 : McMurray Road, Waterloo, Ontario NV G Boiler valve PRJ

27 0-6U 6. KSK -X: -7W T0 xawg 0 VAC GN -7M 0V,.A,0.06kW,ph Grate drive Thermal fuse (Klixon) L M ~ L GND Previous page: 6 Next page: : McMurray Road, Waterloo, Ontario NV G Grate drive M PRJ

28 0 6. / L 6. / L -Q KTA7 -.6A I> I> I> 6-6U 6. KSK -K. 6 -X: -X: 6. / N -K CGMS-A 0VAC A A NO NC.6 -X GND -W T0 xawg -W T0 xawg 0VAC :GN -M K&H 0V,.A,0.kW,ph Rotary blower Thermal fuse (Klixon) L M ~ L GND Previous page: 7 Next page: : McMurray Road, Waterloo, Ontario NV G Rotation blower M PRJ-000 0

29 0-6U 6. ZPK -X7: -X7: -X7: -X7: -X7: -X76: -W xawg VDC +KRT Connection Box -X N PE N PE N PE N PE -Y -Y -Y -Y ASCO ASCO ASCO ASCO VDC VDC VDC VDC Solenoid Solenoid Solenoid Solenoid Previous page: valve valve valve valve Next page: 0 : McMurray Road, Waterloo, Ontario NV G Solenoid valves (pneumatic cleaning system) PRJ-000 0

30 0 6. / CCD. 6. / CCD. -X GND Combustion chamber safety device. remove jumper if installed. Previous page: Next page: 0 : McMurray Road, Waterloo, Ontario NV G Combustion chamber door safety PRJ

31 0 Connection/Cable overview F0_00 Connection/Cable tag W 6W 6W 6W W W W 0W W W W Source (from) Target (to) Wire/Cable type All conductors U X T0 X 6N T0 X 6N T0 X 6N T0 X M T0 6 X M T0 6 X M0 T0 X T0 X M T0 X M X S. W X B. W6 X B. W X M T0 W X M W X S. W X S. W W FU M LF00S shielded X M 6W 6U-X 6B. 6W 6U-X 6B. 7W 6U-X 7B. 7W 6U-X 7B. W 6U-X B. W 6U-X6 B. W W 0W 6U-X 0M 6 W 6U-X M0 6 W X7 6U-X7 W 6U-X X0 W 6U-X X0. W 6U-X0 X.0 W 6U-X X0 W W W W 6W 7W W W W 6U-X X7 X7 N 6U-X U6 X T0-X T0-X X X6 T0 X6 X M6 6Y0 Module cable 7M 6U-X T0 6U-X M T0 X M T0 +KRT-X 6U-X7 6U-X7 6U-X7 Conductors used Cross-section Length [gauge] [ m ] AWG AWG AWG AWG 6 AWG 6 AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG 6 AWG 6 AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG Remark Power supply 0//60 Safety temp. limiter Low water cut-off Water pressure safety switch De-ashing auger De-ashing ascending conveyor auger Boiler pump Fault alarm Loader module Loader module thermal fuse Limit switch maintenance cover Light barrier metering container transmitter Light barrier metering container receiver Spring-operated extraction system Spring-operated extraction system thermal fuse Limit switch maintenance cover Limit switch for silo door Exhaust fan Exhaust fan thermal fuse Light barrier embers transmitter Light barrier embers receiver Light barrier embers transmitter Light barrier embers receiver Light barrier de-ashing system transmitter Light barrier de-ashing system receiver Water level safety switch = Secondary airflow valve Primary airflow valve Storage tank sensors Boiler supply sensor Boiler return sensor Exhaust gas sensor Loader module sensor Lambda sensor Sluice valve Ignition blower = Mixing valve Grate drive Rotary blower thermal fuse Rotary blower Solenoid valves Voltage 0VAC 0VAC 0VAC 0VAC 0VAC/0VAC 0VAC/0VAC 0VAC 0V max. 0VAC V V 0VAC V V V 0VAC V V V V V VDC 0VAC 0VAC VAC 0 VAC 0VAC VDC Previous page: 0 Next page: : McMurray Road, Waterloo, Ontario NV G Cable overview : W - W PRJ

32 0 Connection/Cable overview F0_00 Connection/Cable tag Source (from) Target (to) 6U-X7 Wire/Cable type All conductors Conductors used Cross-section Length [gauge] [ m ] Remark Voltage Previous page: 0 Next page: : McMurray Road, Waterloo, Ontario NV G Cable overview : W - W PRJ

33 0 Terminal diagram F_00 Function text W T0 W T0 W T0 W T0 6W T0 6W T0 6W T0 W T0 Connection tag Wire/Cable type External Target designation Connection point Terminal Strip X Line voltage connections Jumper Internal Target designation Connection point Page / column Previous page: 0. Next page:. Power supply 0//60 U L Q L. = U L Q L. = U L Q L. = WH U N N N-bus. = GN U G GND. Safety temp. limiter (STL) 6N 6U-X 6. = 6N 6U-X 6. = :GN 6N GND GND 6. Low water cut-off :WH 6N L N N-bus 6. = 6N L 6 6F 6. = 6N P 7 6U-X 6. = 6N P 6. = :GN 6N GND GND 6. Water safety pressure switch 6N 6U-X 6.6 = 6N 0 6U-X = :GN 6N GND GND 6.6 De-ashing auger M U K. = M V K. = M W K 6. = :GN M PE GND. De-ashing auger thermal fuse M F. = 6 M. De-ashing ascending conveyor auger M U 6 K. = M V 7 K. = M W K 6. = :GN M PE GND. De-ashing ascending conveyor auger thermal fuse M. = 6 M 0 6U-X. Boiler pump M0 L K0. = M0 L K0. = M0 L K0 6. = GN M0 GND GND. Loader module M U U U. = M V U V. = M W 6 U W. : McMurray Road, Waterloo, Ontario NV G Terminal diagram : X PRJ-000 0

34 0 Terminal diagram F_00 Function text W T0 W T0 W T0 W T0 Connection tag Wire/Cable type External Target designation Connection point Terminal Strip X Line voltage connections Jumper Internal Target designation Connection point Page / column Loader module :GN M PE GND. Spring-operated extraction system M U U U. = M V 6 U V. = M W 7 U W. = :GN M PE GND. Ignition blower X6 7 F. = X6 K.6 = X6 K.6 Spare 0 6U-X60. = N N-bus. = GND. Rotary blower M L K.6 = M L K.6 = :GN M GND GND.6 Combustion chamber door safety 0. = 6U-X 0. = GND 0. Previous page: Next page: : McMurray Road, Waterloo, Ontario NV G Terminal diagram : X PRJ

35 0 Terminal diagram F_00 Function text W W W W W6 W W W Connection tag Wire/Cable type External Target designation Connection point Terminal Strip X V connections Jumper Internal Target designation Connection point Page / column Loader module thermal fuse M U T. = M U T. Limit switch for maintenance cover S. 6K. = S. D. Spare. = 6 D. Light barrier metering container- transmitter BN B. 7.7 = BU B..7 Light barrier metering container- receiver BN B. U. = BU B. 0 U 7. = BK B. U E. Spring-operated extraction system thermal fuse M U T. = M U T. Limit switch for maintenance cover S. 6K. = S.. Limit switch for silo door S. 6. = S. 7 D. Exhaust fan thermal fuse M FU T.6 = M FU T.6 Previous page:. Next page: : McMurray Road, Waterloo, Ontario NV G Terminal diagram : X PRJ

36 0 Terminal diagram F_00 Function text 6W W Connection tag Wire/Cable type External Target designation Connection point Terminal Strip X V connections Jumper Internal Target designation Connection point Page / column Sluice valve T0-X L U. = T0-X N U 7. = T0-X 6 U A. = T0-X 7 U E. = T0-X U 7. Boiler mixing valve 6Y0 OPEN 6K 6.7 = 6Y0 COMM 0 6T 6.7 = 6Y0 CLOSE 6K 6. Previous page: 60 Next page: 6 : McMurray Road, Waterloo, Ontario NV G Terminal diagram : X PRJ

37 0 Terminal diagram F_00 Function text 0W T0 Connection tag Wire/Cable type External Target designation Connection point Terminal Strip X Dry contact outputs Jumper Internal Target designation Connection point Page / column Fault alarm 0K0 0. = 0K0 0. Spare 0. = 0. Previous page: 60. Next page: : McMurray Road, Waterloo, Ontario NV G Terminal diagram : X PRJ

38 0 Previous page: 6 Next page: 0 : McMurray Road, Waterloo, Ontario NV G Schematic diagram PRJ

39 0 () Lines arranged in metal pipe with min distance of 0 mm to the base. Use support with cable routing for light barrier. No support on base. () Screw cable channel (metal) onto the foot plate on top of the boiler with min. distance of 0 mm. () Fasten cable channel (metal) on casing with min. distance of 0 mm. () Cable channel (metal) over entire width of the boiler: fastening on the bottom of the boiler (it is not water-bearing). () Mount cable channel (metal) with min. distance of 00 mm to the feed auger: no support on the feed auger. (6) Arrange lines in protective flexible cable conduit with sufficient leeway to open and close the door (mind the door stop). Previous page: 00 Next page: 0 : McMurray Road, Waterloo, Ontario NV G Arragement of electrical wiring PRJ

40 0 Boiler PYROT +KRT Boiler +T - Txx PYROT transport equipment Previous page: 0 Next page: 0 : McMurray Road, Waterloo, Ontario NV G Boiler lay-out PRJ

41 0 Loader module T Spring-operated extraction system T - Motor M - Limit switch for maintenance cover S. - Slide valve T0 - Light barrier B. (transmitter) - Light barrier B. (receiver) - Motor M - Limit switch for maintenance cover S. - Limit switch for silo door S. Previous page: 0 Add T.0. : McMurray Road, Waterloo, Ontario NV G Overview of loader system Next page: PRJ

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Power connections, minimum and maximum wiring capabilities, tightening torque

Power connections, minimum and maximum wiring capabilities, tightening torque Wiring - power terminals Power Observe the cable cross-sectional areas recommended in the standards. The soft starter must be grounded to conform to the regulations concerning leakage currents. If the

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Communication. Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus. Technical, Installation and Configuration Information

Communication. Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus. Technical, Installation and Configuration Information Versatronik 532 & 532D Solar Communication Gateway for solar controls Modbus Document Applicable to: Versatronik 532 Solar/Modbus P/N 704089 Versatronik 532D Solar/Modbus P/N 704090 Communication Applicable

More information

- Wiring Brochure Universal Reset Module 423e

- Wiring Brochure Universal Reset Module 423e - Wiring Brochure Universal Reset Module 4e W 4e 0/08 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications Rough In Wiring Rough-in wiring

More information

Communication. Versatronik 501 & 501D LON Communication Gateway. Technical, Installation and Configuration Information. Cautionary Statement

Communication. Versatronik 501 & 501D LON Communication Gateway. Technical, Installation and Configuration Information. Cautionary Statement Versatronik 50 & 50D LON Communication Gateway Document Applicable to: Versatronik 50 NR2/LON P/N 704049 Versatronik 50D NR2/LON P/N 704068 Communication Applicable Controls Vitocontrol-S, MW and MW2 Vitotronic

More information

Digital Room Sensor Technical Guide

Digital Room Sensor Technical Guide www.orioncontrols.com Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Environmental Requirements...

More information

ISOLATED AC/DC POWER SUPPLY

ISOLATED AC/DC POWER SUPPLY FEATURES IPS-2/24 Transformer isolation Selectable voltage outputs Thermal overload protected Fused outputs Snap track mounted APPLICATIONS AC power isolation Isolated DC power supply 2, 3 & 4 wire transmitter

More information

- Wiring Brochure Universal Reset Module 423

- Wiring Brochure Universal Reset Module 423 - Wiring Brochure Universal Reset Module 423 W 423 03/09 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet RG4-AM56- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 746 Mulfingen Phone: +49 8 8- Fax: +49 8 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG4-AM56- MG-EA Phase ~ Nominal voltage [VAC]

More information

Explosion Proof Page/Talk Paging Amplifier

Explosion Proof Page/Talk Paging Amplifier Industrial Communications Worldwide Explosion Proof Page/Talk Paging Amplifier Installation & Operation 7552-10 th Street. N.E. Calgary Alberta, Canada T2E W1 Ph: 403.25.3100 \ email:info@guardiantelecom.com

More information

FEATURES OPTIONAL FEATURES

FEATURES OPTIONAL FEATURES -00--0 B Series The Assured Automation B Series electric valve actuators offer a rugged design for quarter turn industrial applications. Designed for use on quarter turn (0 ) ball valves, butterfly valves,

More information

200 Watt Passive Shunt Module

200 Watt Passive Shunt Module Installation Instructions 200 Watt Passive Shunt Module (Catalog Number 9101-1183) Drives can require external power dissipation when large inertial loads are present. To ensure that faults due to excessive

More information

Code. Edition 04/2013. CPA Screw Air Compressors. Parts List Book

Code. Edition 04/2013. CPA Screw Air Compressors. Parts List Book Code 2205 1084 06 Edition 04/2013 CPA7.5-10-15-20 Screw Air Compressors Parts List Book REF. PART NUM. QTY. NAME REF. PART NUM. QTY. NAME 1095 2205 1020 83 1 BASE 1195 2205 1053 83 1 PANEL 1100 2205 1028

More information

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES PEAKTRONICS The Peaktronics AC Motor Interface is used to interface common electrical control signals to AC actuators. The unit provides the motor drive circuits, protection circuits, and isolation between

More information

IS-3000 SERIES INFRARED SCANNER

IS-3000 SERIES INFRARED SCANNER IS-3000 SERIES INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES ANALOG AND DIGITAL OUTPUTS INDICATIVE OF TARGET POSITION, WIDTH AND TEMPERATURE

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Puppet - II+ Controller (BPE No. PCA-0001) Servo Position Adjustment EEPROM Digital Button Power 5 Vdc Playback

More information

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice. Instruction Manual Bypass Panels FRENIC-EcoPAK Fuji Electric Corp. of America FECA-IN-105 / 122010 Information subject to change without notice. Safety Precautions Read this manual thoroughly before proceeding

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

Sealed Interface Control: EC20300

Sealed Interface Control: EC20300 ISO 9001:2000 WITH DESIGN Certificate #02.002.1 Sealed Interface Control: EC20300 FEATURES: Weather tight control package Pulse Width Modulated output Waterproof altitude pressure and vapor release vent

More information

Effective october 14, 2014

Effective october 14, 2014 MARK V XCEL & Mark V-00 XCEL ELECTRIC convection oven REPLACEMENT PARTS LIST Effective october, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

FT201 PRODUCT MANUAL PART NUMBER: SG REVISION: A

FT201 PRODUCT MANUAL PART NUMBER: SG REVISION: A FT201 PRODUCT MANUAL PART NUMBER: SG072310005 REVISION: A FT201 PRODUCT MANUAL General The FT201 is designed to be both a tester and demo unit for spreader controls. Using the proper interface cable the

More information

CLASSIC 300D Kubota PARTS LIST FOR RETURN TO MAIN INDEX

CLASSIC 300D Kubota PARTS LIST FOR RETURN TO MAIN INDEX Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-498 P-498 RETURN TO MAIN INDEX PARTS LIST FOR CLASSIC 300D Kubota P-498-A P-498-A

More information

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE Simple Sturdy Economical LABEL by Invest in Confidence EZ Weatherproof Quarter-turn Actuators EZ RANGE 2 Industrial actuation made easy BERNARD CONTROLS, inventor of the industrial compact quarter turn

More information

CONTROL UNITS. VEHICLE EXHAUST GASES Pure advantages VEHICLE EXHAUST GASES

CONTROL UNITS. VEHICLE EXHAUST GASES Pure advantages VEHICLE EXHAUST GASES CONTROL UNITS VEHICLE EXHAUST GASES Fumex s control s offers a good working environment, adapted to all types of facilities. The right choice of control s is energy-saving and provides the lowest possible

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

CHAPTER 3 WIRING DANGER

CHAPTER 3 WIRING DANGER CHAPTER WIRING DANGER Hazardous Voltage Before accessing the AC drive: Disconnect all power to the AC drive. Wait five minutes for DC bus capacitors discharge. Any electrical or mechanical modification

More information

CONTROL MANUAL. Dry-Pic 09PE - 09VE

CONTROL MANUAL. Dry-Pic 09PE - 09VE CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth

More information

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO PART - A : SPECIFIC REQUIREMENTS THIS DATA SHEET IS APPLICABLE FOR IN BOILER A CLIMATIC CONDITIONS PACKAGE 1 DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.71 MTRS. 3 RELATIVE HUMIDITY 74 %

More information

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting FANs 216, 121 Technical Bulletin R48 Issue Date 0695 Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting Table of Contents Mounting... 1 Output Control... 2 Wiring...

More information

QUICK REFERENCE. A-Size (7/8 ) powerfast. D-Size (1 3/8 ) powerfast. M16 powerfast. M23 powerfast. M40 powerfast. 3 & 4 pole 14 AWG conductors

QUICK REFERENCE. A-Size (7/8 ) powerfast. D-Size (1 3/8 ) powerfast. M16 powerfast. M23 powerfast. M40 powerfast. 3 & 4 pole 14 AWG conductors QUICK REFERENCE A-Size (7/8 ) powerfast D-Size (1 3/8 ) powerfast M16 powerfast 3 & 4 pole 14 AWG conductors Tray rated-exposed run PVC cable STOOW cable available Up to 15 Amp, 600 Volt rated NEMA 1,3,4,6P

More information

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web:  - Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot

More information

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM Version 3.0 (European version 1.3) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers

More information

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

MODEL 140 VIBRATION TRANSMITTER

MODEL 140 VIBRATION TRANSMITTER OPERATION MANUAL MODEL 140 VIBRATION TRANSMITTER Includes 140-1, -2, -5, -X and 140-T-1, -2, -5, -X Page 2 MODEL 140 TABLE OF CONTENTS 1. INTRODUCTION... 3 Description... 3 2. FEATURES... 3 Piezoelectric

More information

HLC-1000 High-limit Humidity Control

HLC-1000 High-limit Humidity Control FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification

More information

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany 2354235 11/2008 Soft start - soft stop unit SH31 User manual 09/2010 BLEMO Frequenzumrichter Siemensstraße 4 D-63110 Rodgau Dudenhofen Germany Tel.: ++49 / 6106 / 82 95-0 Fax: ++49 / 6106 / 82 95-20 Internet:

More information

Installation/Operation Manual

Installation/Operation Manual Installation/Operation Manual USM GEN2 Universal Sensor Module Form USM GEN2 IOM 9/15 1 1.0 DESCRIPTION 1.1 The USM GEN2 reduces on-skid conduit and tubing runs by bringing the process information into

More information

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads) Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Sizes Are coordinated with the dimensions, connections S00...S3 S00... S12 S00... S12 and technical characteristics of the other devices in the

More information

E-BUS Digital Room Sensor Technical Guide

E-BUS Digital Room Sensor Technical Guide E-BUS Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Dimensions... 5 Environmental Requirements...

More information

SCHMIDT Flow Sensor SS SS FB

SCHMIDT Flow Sensor SS SS FB Product description Flow sensor with integrated microcontroller transducer for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. The aerodynamically styled

More information

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual C Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3 Printed in U.S.A. Maintenance Manual TABLE OF CONTENTS DESCRIPTION.................................................... 1 CIRCUIT ANALYSIS.................................................

More information

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H018F1 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component

More information

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application

More information

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2

More information

CONTENTS XV300K GB r doc XV300K 2/13

CONTENTS XV300K GB r doc XV300K 2/13 XV300K CONTENTS 1 PRELIMINARY CHECK GUARANTEE RECYCLING... 3 2 XV300K SPECIFICATIONS OF USE... 3 3 CODES - MODELS... 4 4 TECHNICAL SPECIFICATIONS... 4 5 STANDARD REFERENCES... 5 6 MECHANICAL INSTALLATION...

More information

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual DPAfour125, DPAfour250 AMPLIFIERS Operating Manual Operating manual, DPA Series DPA-10UMS01-V01R04 version revision date 01 02 24-02-2012 www.ateis-europe.com ATEÏS Europe BV - Sydneystraat 42-3047BP ROTTERDAM

More information

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,

More information

LA-5000 SERIES LINEAR VALVE ACTUATORS

LA-5000 SERIES LINEAR VALVE ACTUATORS LA-5000 SERIES LINEAR VALVE ACTUATORS GENERAL DESCRIPTION The LA-5000 Series are bi-directional, linear actuators internally geared to produce up to 6,500 lbs. (28,913 N) of thrust, and offer continuous

More information

GI/EMME SERIES

GI/EMME SERIES The GI/EMME 1400-4500 series of burners covers a firing range from 820 to 4650 kw. They ave been designed for high output users and they are suitable for matching with every kind of boilers, with normal

More information

diode led 24VDC COMMERCIAL GRADE SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2.

diode led 24VDC COMMERCIAL GRADE SPECIFICATION SHEET RECEIVE A UL LISTED DRIVER WHEN ORDERING THE LO-PRO JUNCTION BOX & DRIVER COMBO ON PAGE 2. diode led a division of elemental LED 24VDC COMMERCIAL GRADE 0-10V LED DIMMABLE DRIVER 24VDC WET LOCATION DIMMABLE SPECIFICATION SHEET OVERVIEW 24VDC Commercial Grade 0-10V Dimmable LED Drivers are essential

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

Servo Amplifier - Troubleshooting Guide

Servo Amplifier - Troubleshooting Guide Haas Technical Documentation Servo Amplifier - Troubleshooting Guide Scan code to get the latest version of this document Translation Available There are four versions of Haas amplifiers. 30A [1], 45A

More information

Instruction manual for STA 1 sectional door operator

Instruction manual for STA 1 sectional door operator Instruction manual for STA 1 sectional door operator Sectional door operator STA 1 / Rev. 0.3 1 GB 1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions

More information

Non-Spring Return DuraDrive Modulating Actuator

Non-Spring Return DuraDrive Modulating Actuator MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

Level Limit Switch nivotester FTL 325 P

Level Limit Switch nivotester FTL 325 P Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit

More information

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B Instruction Sheet P/N 1047806B Installation of Fillmaster DuraBlue Melters System on WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use

More information

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces: Valve amplifier for proportional valves Type VT-SSPA- (5, 50, 00, 50) RE 306 Edition: 05-03 Replaces: 04-07 Component series X Analog, connector design Suitable for controlling solenoid-actuated pressure

More information

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD) Drives 101 Lesson 3 Parts of a Variable Frequency Drive (VFD) This lesson covers the parts that make up the Variable Frequency Drive (VFD) and describes the basic operation of each part. Here is the basics

More information

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20 CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: WIRING CODE 1 3 Wire system, single pole double throw, switching the live SPDT 2 3

More information

Field Devices and Wiring

Field Devices and Wiring Field Devices and Wiring Slide 2-1 Field Device and Wiring Overview The control system interfaces to the process through field devices. Our ability to control a process is limited to the accuracy of measurement

More information

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring. A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Overview Principle of Operation The ORCA

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S. EN SolidFlow.0 Product Information Solid mass flow measurement SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.A Group Use SolidFlow.0 has been specially developed for measuring

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable

More information

REDKOH INDUSTRIES SWITCH MODE POWER SUPPLY DEMO UNIT

REDKOH INDUSTRIES SWITCH MODE POWER SUPPLY DEMO UNIT Installation Guide REDKOH INDUSTRIES SWITCH MODE POWER SUPPLY DEMO UNIT These Demo Units are typically available for 30 day loans. Redkoh Requests that the customer pays the freight of the unit to and

More information

DIGITAL FEEDER CONTROL

DIGITAL FEEDER CONTROL CONTROL Version - March 010 For Software Version V3.16 For Digital Control Part Numbers 06-080 - 1/4vDC Switching Positive 06-085 - 1/4vDC Switching Negative or 1/4vAC Part Number - 39-0050 CONTROL: INDEX

More information

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947 Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit

More information

AEE Solar Toroid Autotransformers. OutBack Power

AEE Solar Toroid Autotransformers. OutBack Power AC Transformers Use an autotransformer as a step-down to connect the 240 VAC output of a generator to the 120 VAC input on an inverter. This allows full output power of a 240 VAC generator to be used for

More information

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet RG6-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG6-AB6- MG-IF Phase ~ Nominal voltage [VAC]

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

RS /M MZ SERIES

RS /M MZ SERIES The RS 310-410-510-610/M MZ burners series covers a firing range from 1300 to 6300 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Animatronic Wizard - 3 Board (BPE No. WAC-0030) Version 3.0 2009 Controller Page 1 The Wizard 3 Board will record

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR RODIX INC. FEEDER CUBE FC90 Plus Series ADVANCED FEATURES Optional software features of the 24490 / 2449 circuit boards OVERVIEW: The FC90 Plus Series of feeder controls are built around the circuit boards

More information

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal R3G3-RO36-8 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court

More information

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6 Analogue amplifier RE 29980/09.05 Replaces: 02.03 1/6 Type VT-SR2 Series 1X H5658 Table of contents Contents Page eatures 1 Ordering code 2 unctional description 2 Technical data 3 Block circuit diagram

More information

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699) MILLENNIUM HEAD PRESSURE CONTROL KIT FOR LOW AMBIENT APPLICATIONS INSTALLATION INSTRUCTION Supersedes: 530.70-N.8Y (399) 530.70-N.8Y (99) HEAD PRESSURE CONTROL FOR 208/230 & 0V 25, 30 & 0 TON MILLENNIUM

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,

More information

PARTS LIST: Air Control Assembly (1632 Sander)

PARTS LIST: Air Control Assembly (1632 Sander) PARTS LIST: Air Control Assembly (1632 Sander) 1 6293482 Filter... 1 2 6293483 Solenoid Valve... 1 3 6293484 Brake Cylinder... 1 4 6293485 Multi-Hole Connector... 1 5 6293486 Air Valve... 1 6 6293487 Air

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring. A Higher Level of Performance Data Sheet ORCA Sonar System Sludge and Settling Level Interface Monitoring For more information, please visit > www.hawkmeasure.com Principle of Operation The ORCA Sonar

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display

More information

Blue Point Engineering

Blue Point Engineering DMX -Channel Relay Board Overview A two-channel DMX relay switch for switching loads up to 0A at 40V AC per channel. he DMX switch operates on the standard DMX5 bus and requires - DMX channels for operation.

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual External RF Driver Electrical Driver for AOTF-crystal Instruction Manual Table of Contents 1 General... 3 2 Compliance... 3 3 Labeling... 4 4 Interface... 5 4.1 Front Panel... 5 4.2 Back Panel... 6 4.2.1

More information

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional valves with electrical position feedback Valve amplifier for proportional valves with electrical position feedback Type VT-MRPA1-... RE 30221 Edition: 2015-02 Replaces: 2013-08 Component series 1X Analog, modular design Intended for controlling

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Conductive Sensors 2 to 4-point level controller Type CL with potentiometer

Conductive Sensors 2 to 4-point level controller Type CL with potentiometer Conductive Sensors to 4-point level controller Type CL with potentiometer Conductive level controller Adjustment of sensitivity operating resistance from 50Ω to 500KΩ Multiple combinations of filling and

More information