1 Universal Isolation Amplifiers The Universal Isolation Amplifier. The Inputs On the Knick DC isolation amplifiers, the input is symmetrical, i.e. both input terminals can be exchanged without undesired effects on the common mode rejection. Models with connections for external gain setting, zero-point setting, and live-zero switching ( ma /... 0 ma) are available for special tasks. The Models Knick's series features a tried and tested range of powerful DC isolation amplifiers that have excellent specifications despite their small dimensions and feature a symmetrical input with high common mode rejection. The Applications The isolation amplifiers are easy to use, particularly for applications where small dimensions are required in conjunction with high isolation voltages, high accuracy and maximum reliability. The Problems When conventional unsymmetrical isolation amplifiers are used, measurement signal interference which seems inexplicable to the user at first can occur. If, for example, there are several devices in series in a current output loop, an isolation amplifier can meet a LO output with its HI input which can cause the above-mentioned signal interference. 38
2 For up-to-date information, please visit Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Facts Symmetrical input with high common-mode rejection Excellent specifications High isolating voltage High output power Optional external gain adjustment with just one resistor Live-zero switching (0 0 ma / 0 ma) Miniature pancake design for circuit board installation High quality and reliability 00 % computer controlled production monitoring and final inspection -year warranty Warranty years! Warranty Defects occurring within years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Complete modules without external wiring 39
3 Universal Isolation Amplifiers Product Line Device Symmetrical input Impressed output Load capability Order No. free wiring Up to ±00 mv according to the wiring Up to ±00 mv according to the wiring ±0 ma 0 V ) 00 M ±0 V ) 0 ma 00 M fixed settings ±0 mv ±0 mv ±0 mv ±00 mv ±0 V ±0 ma ±0 ma 0 V ) 0 M 0 M M 0 M 30 M 80 M ±0 mv ±0 mv ±0 mv ±00 mv ±0 V ±0 ma ±0 V 0 ma 0 M 0 M M 0 M 30 M 80 M V DC Option Order No... Output ±0 0 ma and + 0 ma, switchable (for live zero: unipolar input, additional error ± 0 µa) 3 Gain error < 0. % of measured value (not for Model 0) 0 ) ±0 V or 0 V unipolar (note power supply!) Specifications Input data Input Input resistance Overload capacity see Product Line > Mohm, for models with I in ±0 ma:. ohms V in V, I in 300 ma 30
4 For up-to-date information, please visit Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications (continued) Output data Output Offset current 3) Offset voltage 3) Drift Residual ripple see Product Line < 0 na < 00 µv, externally nullable < µv / month 0 mv pp Transmission behavior Gain error < 0.% meas. val., Option 0: 0. % meas. val. Cutoff frequency ) >. khz 3 db (0 mv 00 mv or 0 V) (other values upon request) Temperature coefficient 3)) < na/k, < µv/k (reference temperature 3 C) ±.. V stabilized, approx. 30 ma for unipolar operation up to 0 V, output voltage:, + V stabilized Isolation Galvanic isolation Test voltage Working voltage (basic insulation) 3-port isolation between input, output and power supply kv AC across input and output / power supply 000 V DC at overvoltage category II and pollution degree 3 according to EN 00- For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. Standards and approvals EMC European EMC regulations; according to 89/33/EEC Further data Ambient temperature ºC Design Weight Module, encapsulated See dimension drawings for measurements Approx. g ) Current output up to 0 ohms load, models 30 and 30 up to 0 V pp 3) x 0 for models 30, 30 ) Offset set to zero 3
5 Universal Isolation Amplifiers Connection Diagrams Connection Diagram 000 M + ± 0 00 mv ± 0 ma (Model 80 M) ± 0 V (Model 30 M) 000 M (opt. 3) R G (model 00) + 0 ma ±0 0 ma + V 0 V ± Output 0 Symmetrical input galvanically isolated 00 kohms Zero adjuster - V Model 00: R G = V in 0 [ohm, mv] ( ohms) Connection Diagram 000 M + ± 0 00 mv ± 0 ma (Model 80 M) ± 0 V (Model 30 M) 000 M 3 R G (model 00) + V 0 V ± Output 0 Symmetrical input galvanically isolated 00 kohms Zero adjuster - V 000 V Model 00: R G = in [ohm, mv] (. 09 ohms) 0000 U in 3
6 For up-to-date information, please visit Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Dimension Drawing and Pin Assignments S S S Pin view S S Input + Input Output ± 0 0 ma, R G Output + 0 ma, (Opt. 3) R G (Model 00) Zero + 8 adjuster 9 00 kohms Connect output 0 to 0 V power supply source S Input + Input S = Grid spacing =. mm Pin view 3 3 Output 0, power supply 0 V, R G Output ± R G (Model 00) Zero + 8 adjuster 9 00 kohms. 3S S 3S 0S Ø approx All dimensions in mm 33
IsoAmp 11000/ Universal isolation amplifiers for ±20 mv to ±10 V or ±20 ma input signals.
Universal Isolation Amplifiers IsoAmp 11000/12000 Universal isolation amplifiers for ±20 mv to or input signals. The Problems When conventional unsymmetrical isolation amplifiers are used, measurement
More informationIsoAmp 3000/4000. The Advantages The dynamic range extends into the negative, allowing for strictly linear transmission
Standard-Signal Isolation Amplifiers For transmission and conversion of impressed measurement signals. The components typically required for modulation amplifiers and resistance networks are unnecessary.
More informationLoop-Powered Isolators for Standard Signals
Loop-Powered Isolators for Standard Signals For isolation of 0(4) 20 ma standard signals without power supply in 19" technology The Housing The integration of several modules on one Eurocard results in
More information5 years! Modular Housings. IsoAmp PWR A Warranty
IsoAmp PWR A 20100 Repeater power supply in a 6-mm housing with calibrated switching of output signals, HART transmission, and Safe Isolation The Task Flexible and safe supply of 2-wire transmitters via
More information5 years! Modular Housings. VariTrans P Warranty
Modular Housings VariTrans P 27000 The Multimeter among the isolators. With 480 switchable calibrated ranges and broad-range power supply. The Task A wide range of measuring signals need to be galvanically
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS
High-Voltage Isolation Amplifiers / Shunt Isolators AC/DC high-voltage isolators for true rms measurement Input voltages up to Vin = 3600 V AC The Task In electrical systems, alternating voltages from
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000
High-Voltage Isolation Amplifiers / Shunt Isolators VariTrans P 29000 Compact high-voltage isolators with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection.
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS
AC/DC high-voltage isolators for true rms measurement Input currents ranging from Iin = 100 ma AC to Iin = 5 A AC The Task In electrical systems, alternating currents from 100 ma to 5 A need to be recorded,
More informationVariTrans P D1 TRMS
Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True
More informationIt s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.
It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P 40000 TRMS series Isolation Amplifiers Isolation Amplifiers A Class of Its Own. AC/DC High-Voltage With True
More informationVariTrans P V. Safe and Sound.
1000 V. Safe and Sound. VariTrans P 29000 Compact high-voltage isolation amplifiers with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection. Isolation Amplifiers
More informationIsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.
ProLine Interface Technology Loop-Powered Isolators for Standard Signals For isolation of 0(4)... 20 ma standard current signals on up to 3 channels. The Task If no power supply is available, the galvanic
More informationVariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.
ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task
More informationMaconic Shunt Resistors
The Art of Measuring. Reliable measurement of DC currents up to the ka range with a high level of accuracy Maconic Shunt Resistors Maconic Shunt Resistors Usage In many areas of applications the use of
More informationProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv
Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters
More informationUser and Safety Manual ProLine P224xx P1
The Art of Measuring. User and Safety Manual ProLine P224xx P1 English 17 Loop-Powered Isolators/Splitters www.knick-international.com Contents 17 Safety Information 18 Short Description 19 Intended Use
More informationTransducer for Measurement Bridges SCM90, SIGS15
Transducer for Measurement Bridges SCM90, SIGS15 General Description Transducer for measurement bridges for DINrails and for printed circuit boards. Programmable ranges and bridge supply, voltage or current
More informationThe Art of Measuring. Interface Technology Product Overview. ProLine
The Art of Measuring. Interface Technology Product Overview ProLine ProLine Interface Technology The Art of Measuring. 5-year warranty! Isolation amplifiers and transmitters from Knick enjoy a unique reputation
More informationAnalog signal converters CC-E I/I
2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage
More informationType Ordering Code Package TAA 762 A Q67000-A2271 P-DIP-6-1 TAA 762 G Q67000-A2273 P-DSO-6-1 (SMD) TAA 765 A Q67000-A524 P-DIP-6-1
Single Operational Amplifiers TAA 762 Bipolar IC Features Wide common-mode range Large supply voltage range Large control range Wide temperature range (TAA 762) High output frequency compensation Open
More informationA E 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 500 W (source) 150 W (sink) DATA SHEET
A1110-05-E 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 500 W (source) 150 W (sink) DATA SHEET The A1110-05-E is a linear, extreme broadband precision power amplifier. It is ideally suited
More informationHigh Performance Current Transducer ITL 900-T = A
High Performance Current Transducer ITL 900-T For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. I PM = 0... 900 A Electrical
More informationMODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series
MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating
More informationModule Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc
HSI Series Modules Selection Guide HSI Series Modules Single channel High bandwidth - for dynamic signals Isolation (all models Analog signal output (±5 V Single channel modularity For DEWETRON systems
More informationIsolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC
Selection Guide PAD Series Modules Multi channel Low bandwidth - for static signals Isolation Digital output (RS-485) Exchangeable For DEWETRON systems with built-in DAQ rack Module # CH Input type Ranges
More informationA QE 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 1000 W (source) 650 W (sink) DATA SHEET
A1110-16-QE 4-quadrant voltage and current amplifier DC 1 MHz 100 V/µs 1000 W (source) 650 W (sink) DATA SHEET The A1110-16-QE is a linear, extreme broadband precision power amplifier. It is ideally suited
More informationGAMMA 20 DIGITAL MULTIMETER
Gamma 20 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel
More informationA A 4-quadrant voltage amplifier DC 1 MHz 100 V/µs 500 W (source) 90 W (sink) DATA SHEET
A1110-05-A 4-quadrant voltage amplifier DC 1 MHz 100 V/µs 500 W (source) 90 W (sink) DATA SHEET The A1110-05-A is a linear, extreme broadband precision power amplifier. It is ideally suited for applications
More informationFunctional Description
Page 1 of 5 Submit Feedback Function Illustration The BMX AMI 0810 is a high density input analog module with 8 isolated channels. This module is used in conjunction with sensors or transmitters; it performs
More informationLOW NOISE / LOW DRIFT DIFFERENTIAL AMPLIFIER SP 1 004
Physics Basel Electronic Lab Klingelbergstr. 82 CH-4056 Basel Switzerland MICHAEL STEINACHER TEL: 0041 61 207 37 22 FAX: 0041 61 207 37 84 E-MAIL: MICHAEL.STEINACHER@UNIBAS.CH WEB: HTTP://WWW.PHYSIK.UNIBAS.CH
More informationCoupling Relays and Converters
Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard
More informationTechnical Information Barrier RB223
TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits
More informationLow Noise Variable Gain Low Frequency Voltage Amplifier
Measurement Features Variable Gain 40 to 100 db, Switchable in 20 db Steps Bipolar Input Stage, Recommended for Low Impedance Sources Smaller than 100 Ω Very Low Input Voltage Noise: 700 pv/ Hz DC-Coupled,
More informationHigh Performance Current Transducer IT 200-S ULTRASTAB = A. ε L
High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM
More informationLow Noise Variable Gain Low Frequency Voltage Amplifier
Features Variable Gain 40 to 100 db, Switchable in 20 db Steps Bipolar Input Stage, Recommended for Low Impedance Sources Smaller than 100 Ω Very Low Input Voltage Noise: 700 pv/ Hz DC-Coupled, Single
More informationCurrent Transducer CTSR 1-P = 1A
Current Transducer CTSR 1-P I PRN = 1A For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary (high power) and the secondary circuit (electronic circuit).
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 700-S ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
Current Transducer CTSR 0.6-TP/SP2 I PRN = 600 ma For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. Features
More informationDQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1000A Features Linearity error maximum 1 ppm Fluxgate,
More informationVariable Gain Low Frequency Voltage Amplifier
Features Applications 20 to 80 db, Switchable in 20 db Steps Bipolar Input Stage, Recommended for Low Impedance Sources Smaller than 1 kω Single Ended and True Differential Input Models Bandwidth DC -
More informationDS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer ITN 1000-S ULTRASTAB I PM = 1000 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation
Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to
More informationAnalog Isolation Amplifiers
Isolation Amplifiers Analog Isolation Amplifiers HSI/DAQ Series Modules DEWETRON high precision signal conditioning amplifiers are available for almost any sensor to measure Voltage Current Pressure Temperature
More informationDL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.
DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationTemperature Transmitters - Head Mounted
XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationDS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 0 ppm offset Current
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationPART NUMBERING SYSTEM
Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover)
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 700-SB ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features ± 10 V voltage output
More informationPART NUMBERING SYSTEM
Plug-In Timer pins Multifunction or monofunction Compact body for space saving Wide time range (from 0. seconds to 0 days delay) niversal power supply (-0 Vz) or relay outputs (SPDT / Changeover) Protective
More informationIsolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW
Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationPD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
More informationDS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 370A Features Linearity error maximum 2 ppm 100
More informationLow Noise Variable Gain Low Frequency Voltage Amplifier
Features Variable Gain 40 to 100 db, Switchable in 20 db Steps Bipolar Input Stage, Recommended for Low Impedance Sources Smaller than 100 Ω Very Low Input Voltage Noise: 700 pv/ Hz DC-Coupled, Single
More informationModel 3102D 0-2 kv H.V. Power Supply
Features Compact single width NIM package Regulated up to ±2000 V dc. 1 ma output Noise and ripple 3 mv peak to peak Overload and short circuit protected Overload, inhibit and polarity status indicators
More informationModel 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R
O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com
More informationimc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance
Data Sheet Version 1.9 imc CANSAS-L-HCI8 High isolated module for the capture of temperature, voltage, current (20 ma) and resistance The imc CANSAS module (CANSAS-L-HCI8) enable measurement of low voltage
More informationDS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators
Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 600A Features Linearity error maximum 1.5 ppm Fluxgate,
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationJUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes
Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol
More informationAnalog signal converters CC range
Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally
More informationDIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.
DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC. MODEL SELECTION GUIDE The DIN Series of Digital Panel Meters are rugged low cost meters for the measurement of dc voltage, dc current, Process voltage
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature
More informationS200 I/O System Units
S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features
More informationDM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis
Ultra-stable, high precision (ppm class) fluxgate technology DM Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1500A Features Ø45mm aperture enabling large isolated
More informationUSER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationPrecision amplifier for bridge circuits AM467 PRINCIPLE FUNCTION
PRINCIPLE FUNCTION Adjustable offset and span output signal for differential input signals from 0 to 5 mv FS up to 0 to 100 mv FS. Ratiometric output voltage of 0.2V to Vcc-0.2 V V = 5V _+ 5% CC Differential
More informationOperating Instructions
Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description
More informationSCXI 8-Channel Isolated Analog Input Modules
SCXI 8-Channel Isolated Analog Input NI, NI SCXI-1120, NI SCXI-1120D 8 channels 333 ks/s maximum sampling rate Gain and lowpass filter settings per channel Up to 300 V rms working isolation per channel
More informationMagnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800
IN ONE UNIT: 800W precision power amplifier, Spectrum Analyzer, Signal Generator General: The MTS-800 is a compact test system for broadband generation and measurement of magnetic fields. Its internal
More informationInstruction Manual Model Upconverter
Instruction Manual Model 2006-01 Upconverter October 2013, Rev. B IF IN RF OUT Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or
More informationTemperature Transmitter itemp RTD DIN rail TMT 127
Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationVitrek 4700 Precision High Voltage Meter
Vitrek 4700 Precision High Voltage Meter 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com High Voltage Reference Divider Performance
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer HO-NSM/SP33 series N = 8, 15, 25 A Ref: HO 8-NSM/SP33, HO 15-NSM/SP33, HO 25-NSM/SP33 For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the
More informationSPECIFICATION Item no.: T60404-N4646-X663
SPECIFICATION Item no: T60404-N4646-X663 K-no: 24513 6 A Current Sensor for 5V- Supply Voltage Date: 182014 For electronic current measurement: DC, AC, pulsed, mixed, with a galvanic isolation between
More informationSPECIFICATION Item no.: T60404-N4646-X651
VACUUMSCHMELZE SPECIFICATION Item no: T60404-N4646-X651 K-no: 24507 25 A Current Sensor modul for 5V-supply voltage Date: 10122010 For electronic current measurement: DC, AC, pulsed, mixed, with a galvanic
More informationSPECIFICATION Item no.: T60404-N4646-X662
SPECIFICATION Item no: T60404-N4646-X662 K-no: 24512 15 A Current Sensor for 5V- Supply Voltage Date: 182014 For electronic current measurement: DC, AC, pulsed, mixed, with a galvanic isolation between
More informationHarris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR
Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections
More informationAUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet
AUTOMOTIVE CURRENT SENSOR HC6H500-S Datasheet Page 1/ 5 Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and low
More informationAUTOMOTIVE CURRENT SENSOR HC6H300-S
AUTOMOTIVE CURRENT SENSOR HC6H300-S Page 1/ 5 Introduction Principle of HC6H Family The HC6H Family is for use on the electronic measurement of DC, AC or pulsed currents in high power and low voltage automotive
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current transducer CKSR series N = 6, 5, 25, 5 A Ref: CKSR 6-NP, CKSR 5-NP, CKSR 25-NP, CKSR 5-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary
More informationAUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY Introduction The HAH3DR-S07 family is a tri-phase transducer for DC, AC, or pulsed currents measurement in automotive applications. It offers a galvanic
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer IT 205-S ULTRASTAB I PN = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature
More informationMX1615. Data sheet. Bridge/strain gauge amplifier
MX1615 Bridge/strain gauge amplifier Data sheet Special features 16 individually configurable inputs Connection of strain gauges in quarter-, half- and full-bridge Bridge excitation : DC or carrier frequency
More informationUSB-2404-UI Specifications
Specifications Document Revision 1.1, April, 2011 Copyright 2011, Measurement Computing Corporation All specifications are subject to change without notice. Typical for the range 0 to 60 C unless otherwise
More informationIndicators. Product Catalog
Indicators Product Catalog Blue our sign of perfection. Always better. Knick is introducing the third generation of loop-powered digital indicators which feed themselves from a low voltage drop from the
More informationP3065 LOW PROFILE LINE MATCHING TRANSFORMER PRODUCT DATA SHEET
PRODUCT DATA SHEET LOW PROFILE MATCHING TRANSFORMER P3065 Features Low Distortion Leadfree (Pbfree) RoHS compliant Low Profile (11mm) Vacuum encapsulated IEC 60950 and UL 60950 certified UL Recognized
More informationInstruction Manual Model Upconverter
Instruction Manual Model 2006-02 Upconverter October 2013, Rev. B IF IN RF OUT Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or
More informationVR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm
VR20 - Inductive sensor (LVDT) Measurement range from 25 to 600 mm Technical data: Measurement range [mm] 0 25 0 50 00 80 0 100 0 150 0 200 0 300 0 600 Linearity 0,30% (0,20% Optional), 1,50% for a range
More informationIsolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Linearized 4-Wire RTD Input 5B35 FEATURES Single-channel signal conditioning module that Amplifies, Protects, Filters, and Isolates Analog Input. Isolates and protects a wide variety of four-wire
More informationNI DAQPad -6020E Family Specifications
NI DAQPad -6020E Family Specifications This document lists the I/O terminal summary and specifications for the NI DAQPad-6020E family of devices. This family includes the following devices: NI DAQPad-6020E
More information"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting
Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input
More informationI PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A
urrent Transducer ITZ 5000-SB FLEX ULTRASTAB I PM = 5000 A For ultra-high precision measurement of current: D, A, pulsed..., with galvanic separation between primary and secondary. Separate magnetic head