Integrity Instruments
|
|
- Chad Cook
- 5 years ago
- Views:
Transcription
1 Integrity Instruments XP-A/I User Manual Integrity Instruments P.O. Box Order Phone Pine River Minnesota Fax Phone -- USA Tech Phone XP-A ISOLATED XP-I RS- to RS- Converter
2 Integrity Instruments XP-A/I User Manual Performance Characteristics Operating Temperature Range DC input voltage min. (+V) DC input voltage maximum. (+V) DC input current nominal (+V) XP-A DC input current nominal (+V) XP-I DC input current max. (+V) ESD static discharge (A/B) Baud Rate maximum Baud Rate minimum Number of RS- nodes -0 C to + C (-0F to +F). Vdc Vdc ma 90 ma 0 ma 00 V. Kbps 00 bps Point to Point (SEE NOTE) Maximum cable length 000 feet + Termination resistance Isolation voltage (XP-I ONLY) 0 ohms,000 volts JUMPER SETTINGS JUMPER NUMBER FUNCTION DEFAULT JP JP DTE OR DCE DCE (ORIENTATION) NOTE: RS- is point to point, that is point A to point B only. RS- multi-drop is really RS- wire. DB9 Pinning RS- transmit (output): DB pin RS- RxD receive (input): DB pin RS- Ground DB pin LED Operation The XP-A/I provides a power status and signal LEDS to aid in cabling problems and general operation. Since the signal LEDS are powered only when data is present, they may be illuminated for somewhat brief periods. POWER YELLOW LED : Power to unit when on SIGNAL RED LED : RS- transmitting when on SIGNAL GREEN LED : RS- receiving when on NOTE: When power only is supplied to the unit, the green LED may be on as the RX input lines are floating. Power Supply The XP-A/I requires an external power supply for proper operation. We suggest our PS9J 9 Vdc 00 ma power supply. Power must be in the voltage range. Vdc to.0 Vdc.
3 Integrity Instruments XP-A/I User Manual Jumpers There is a dte/dce jumper associated with the XP-A/I unit. The dte/dce jumpers are inside the unit. Factory default is DTE. If DCE wiring is needed the case will have to be opened. Use a small screwdriver in the slots on the side of the case and twist, this will open the case so the jumpers can be changed. When the jumpers are changed re-assemble the case by squeezing the case pieces together.. JUMPER PHYSICAL POSITION AND ORIENTATION DCE POSITION DTE POSITION DTE DCE JUMPER DTE POSITION SHOWN Y R G TB Termination schematic wiring connection +V in Shield R 0 R 0 R 0 R 0 R 0 R 0 (B) Power Jack (A)
4 Integrity Instruments XP-A/I User Manual RS- Cabling The XP-A/I is designed to operate in a point to point configuration. In a full-duplex configuration a separate pair of data lines are used for the transmit data, and the receive data. The connection for the transmit and receive wiring, as well as the power wiring is shown in the diagram below. XP-A and XP-I full-duplex cable diagram DC power.- Vdc Power supply ground V+ SHLD T- T+ optional cable shield V+ SHLD T- T+ Power.mm horizontal J TB +V in UNIT CAN BE POWERED VIA TERMINAL CONNECTIONS, OR POWER JACK. IF POWERED BY POWER JACK, OTHER UNITS CAN BE POWERED VIA THE TERMINALS Shield T- T+ Terminal Block. mm Cabling Notes: ) and Shld are connected internally within the unit thru a 0 ohm resistor. ) Cable termination is important for long distance and high-speed applications ) Suggested cable: awg stranded twisted pair with shield for cable runs in excess of 00 feet. See also Belden cable #90, #, #90, and #9. ) Note that the transmit and receive wires are cross coupled.
5 Integrity Instruments XP-A/I User Manual Flow Control Options The Microsoft Windows operating systems allow a user to select several RS- flow control options. The XP-A/I supports both Hardware and None options. The Xon/ Xoff flow control is supported only if your RS- target device supports Xon/Xoff. Hardware flow control is also known as RTS/CTS flow control. The PC asserts the RTS (Ready To Send) signal and waits for the connected device to assert CTS (Clear To Send) before transmitting any RS- data. The unit reflects the RTS line back to the CTS line in the RS- device it is connected to. None flow control setting is also supported. Regardless of the flow control method selected, the XP-A/I will automatically handle the RS- transmit and receive signals.
6 9 Y Z A B Integrity Instruments XP-A/I User Manual CONNECTOR DBF P CD DTR DSR CTS RTS RxD J Power.mm vertical VCC JP Jumper quad D N00 C 0 uf C. uf U LML0 VIN VOUT D Green R.k in in T-out RxD T-out C9. uf C- C- C+ C0. uf C+ U SP +V RS- side TTL/CMOS side Vcc +V XP-A Schematic JP (jumpers in - and -) DCE (default) JP (jumpers in - and -) DTE C. uf V+ D Red V- C. uf R 0 R 0 U JUMPER RS- RxD R 0K T-in 0 T-in out out RS- U JUMPER R0 0 C 0 uf C. uf R.k D Yellow R 0 R 0 DI RO +V_Iso Iso U SP90 Vcc +V_Iso Iso R 0 R 0 R 0 R 0 R 0 R 0 VCC R 0 +V in Shield Terminal Block.0mm TB
7 Integrity Instruments XP-A/I User Manual CD DTR DSR CTS RTS RxD RxD R.K RS- R 0 R0 0 C C R 0 uf. uf.k U NKE00S TZ VCC Terminal Block.0mm TB C. uf D Red R 0 C. uf R 0 U HLQT R 0 R 0 TZ J Power.mm vertical RV 9V MOV C0. uf +V C. uf U0B Iso D Yellow TZ RS- side TTL/CMOS side Vin 0V +V U SP V+ V- 0 T-in 9 Vcc C+ T-out T-out in in T-in out out C 0 uf C+ C- C- R.k +V RS- RxD R 0K U SP90 Iso R 0 R 0 R 0 +V in Shield Vcc DI RO Y Z A B CONNECTOR DBF P JP Jumper quad D Green U LML0 VIN VOUT JP (jumpers in - and -) DCE (default) JP (jumpers in - and -) DTE U R.K HLQT +V_Iso +V_Iso Iso R 0 R 0 9 VCC D N00 C9. uf XP-I Schematic C 0 uf TZ
8 Integrity Instruments XP-A/I User Manual NOTES WARRANTY Integrity Instruments warranties all products against defective workmanship and components for the life of the unit. Integrity Instruments agrees to repair or replace, at it s sole discretion, a defective product if returned to Integrity Instruments with proof of purchase. Products that have been mis-used, improperly applied, or subject to adverse operating conditions fall beyond the realm of defective workmanship and are not convered by this warranty. Copyright , Integrity Instruments All trademarks and/or registered trademarks are the property of their respective owners.
A50/A51/A60. June 2008 (4th Edition) All Rights Reserved
A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection
More informationCP485-4 User s Manual
CP485x4 User s Manual Version 1.0 2005 ZYPEX, Inc. CP485-4 User s Manual Table of Contents Table of Contents Product Description 1 CP485x4 Configuration & Setup 2 Power 2 Baud Rate 2 Control Mode 2 Duplex
More informationZCS485 User s Manual. Version ZYPEX, Inc.
ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter
More informationChapter 12: Digital Modulation and Modems
Chapter 12: Digital Modulation and Modems MULTIPLE CHOICE 1. FSK stands for: a. Full-Shift Keying c. Full-Signal Keying b. Frequency-Shift Keying d. none of the above 2. PSK stands for: a. Pulse-Signal
More informationUSER'S MANUAL. Model : K
USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include
More informationConcept of Serial Communication
Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature
More informationUSER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter
USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)
More informationRS-232 / 20mA Interface Converter ELO E00Q. Operation manual
RS-232 / 20mA Interface Converter ELO E00Q Operation manual 2 ELOE00QZKE001 1.0 Introduction 4 1.1 Use of the converter 4 2.0 Operation principles 4 3.0 Installation 4 3.1 Converter connection to RS-232
More informationNon-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449
IC237A IC482A JUNE 1995 IC486A IC487A-F Non-Powered Interface Converters S-232 to S-530 S-422 to V.35 S-232 to S-485 S-232 to S-422/S-449 CUSTOME SUPPOT INFOMATION Order toll-free in the U.S. 24 hours,
More informationFanuc Serial (RS232) Communications Information
Memex Automation Inc. 777 Walkers Line, Burlington, Ontario Canada L7N 2G1 Fanuc Serial (RS232) Communications Information Contents Signal Description Fanuc Serial Cable Information Timing Chart When The
More informationCL4424. Industrial 2.4GHz ConnexLink. User s Manual Version 1.1
CL4424 Industrial 2.4GHz ConnexLink User s Manual Version 1.1 11160 THOMPSON AVENUE LENEXA, KS 66215 (800) 492-2320 www.aerocomm.com sales@aerocomm.com Document Information Copyright Information Copyright
More informationADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.
User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS
More informationModem 1200 baud 500FSD10 EDS500 series - FSK modems
Manual Modem 1200 baud 500FSD10 EDS500 series - FSK modems Application, characteristics and technical data have to be taken from the hardware data sheet: 500FSD10 Data sheet 1KGT150982 Operation The 500FSD10
More informationSMARTALPHA RF TRANSCEIVER
SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design
More informationGREEN HERON ENGINEERING LLC
GREEN HERON ENGINEERING LLC RADIO BOSS USB USER GUIDE DOCUMENT REVISION: 1.1 A UGUST 8, 2013 G R E E N H E R O N E N G I N E E R I N G L L C RADIO AND TELEVISION INTERFERENCE Green Heron Engineering LLC
More informationMDR24x Wireless 2.4GHz Modem
MDR24x Wireless 2.4GHz Modem User s Manual Version 1.1 1000 Park Drive Lawrence, PA 15055-1018 Website: www.blackbox.com Email: info@blackbox.com Order Toll Free in the US: Call 877-877-BBOX (Outside the
More informationUniversal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485
4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel
More informationUniversal RS232/CMOS to RS422/RS485 Converter
TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.
More informationThe I-2532 CAN to Fiber Converter
The I-2532 CAN to Fiber Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the
More informationACT-IR220Li/220LN IrDA Serial Port Adapter
ACT-IR220Li/220LN IrDA Serial Port Adapter Product Specification Summary ACTiSYS Corp. 48511 Warm Springs Blvd, Suite 206 Fremont, CA 94539, USA TEL: (510) 490-8024, FAX: (510) 623-7268 E-Mail: irda-support@actisys.com
More informationECE 4510/5530 Microcontroller Applications Week 6 Lab 5
Microcontroller Applications Week 6 Lab 5 Dr. Bradley J. Bazuin Associate Professor Department of Electrical and Computer Engineering College of Engineering and Applied Sciences Lab 5 Element Hardware
More informationPRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections
-01-1/ 00 by B&B Electronics. All rights reserved. Model Port-Powered RS- Fiber Optic Modem with Handshake Support Description The allows any two pieces of RS- asynchronous serial equipment to communicate
More informationMiniature Synchronous Multipoint Modems
ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours
More informationADA User manual ADA RS-232 to RS-485 / RS-422 Converter
User manual RS- to RS- / RS- Converter Copyright 001-01 CEL-MAR sp.j. 1 io_ada-100_v._en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...
More informationCONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual
5908 SCADAWave Radio Transceiver Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical
More informationACT-IR220L/LE IrDA Serial Port Adapter
ACT-IR220L/LE IrDA Serial Port Adapter Product Specification Summary ACTiSYS Corp. 48511 Warm Springs Blvd, Suite 206 Fremont, CA 94539, USA TEL: (510) 490-8024, FAX: (510) 623-7268 E-Mail: irda-support@actisys.com
More information2006 MFJ ENTERPRISES, INC.
Model MFJ-4416B INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel: 662-323-5869 Fax: 662-323-6551
More informationSerial Communications RS232, RS485, RS422
Technical Brief AN236 Technical Brief AN236Rev A Serial Communications RS232, RS485, RS422 By John Sonnenberg S u m m a r y Electronic communications is all about interlinking circuits (processors or other
More informationThe i-7531 CAN Repeater
The i-7531 CAN Repeater User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationDSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.
DSP4xxFP SA USER S MANUAL A01561 Rev. A This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA700425 and up. DSP4xxSA User s Manual A01561 Rev. X Proprietary Data This document
More informationB BasicATOM Lab Board Data Sheet
Feature Overview: Includes x LCD Display Solderless Prototyping Board.mm Power Connector USB Connector Using FTDI All ATOM Module Compatible Basic Stamp Compatible Power Status LED LED Indicator Lights
More informationAPPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT
ICS ICS ELECTRONICS division of Systems West Inc. AB- APPLICATION BULLETIN SERIAL BACKGROUNDER (Serial 0) INTRODUCTION Serial data communication is the most common means of transmitting data from one point
More informationFOM-5A, 6A Asynchronous Fiber Optic Modems
ORDERING FOM-5A/*/+ Asynchronous Sub-miniature Fiber Optic Modem FOM-6A/*/+/# Asynchronous Miniature Fiber Optic Modem * Specify: F for female 25-pin connector M for male 25-pin connector + Specify: ST
More informationAccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1
INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,
More informationUNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter
User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741
More informationMFJ ENTERPRISES, INC.
Radio Interface Model MFJ-5124K/Y INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment! MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel: 662-323-5869
More informationLecture #3 RS232 & 485 protocols
SPRING 2015 Integrated Technical Education Cluster At AlAmeeria E-626-A Data Communication and Industrial Networks (DC-IN) Lecture #3 RS232 & 485 protocols Instructor: Dr. Ahmad El-Banna 1 Agenda What
More informationHardware Guide. Control Made Simple. Model 401A Signal Generator
Control Made Simple Model 401A Signal Generator Hardware Guide ON OFF LIMIT 1 2 3 4 RXD TXD POWER West Coast Office 1263 El Camino Real Menlo Park, CA 94025 Phone (650) 853-1444 Fax (650) 853-1405 www.flashcutcnc.com
More informationIntegrity Instruments
Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485M300 Series I/O Modules Digital
More informationBasicATOM Lab Board Data Sheet
Feature Overview: Includes x LCD Display Solderless Prototyping Board.mm Power Connector USB Connector Using FTDI Sockets for all BasicATOM and BasicATOM Pro Modules Power LED LED Indicator Lights Tactile
More informationInstallation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE
Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation
More informationG.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis
JUNE 1998 MT243A MT243C-F RM243A G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday:
More informationElectronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge
Electronics / Water analogy Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Resistor U = R * I 1 Capacitor U 1 i dt C U L di dt Inductance Turbine Flywheel Diode Transistor
More informationTS4000 Radio Modem. User s Manual
TS4000 Radio Modem User s Manual Version 6.60C 1729 South Main Street Milpitas, CA 95035 (408) 941-1808 (800) 663-3674 (408) 941-1818 Fax www.teledesignsystems.com productsales@teledesignsystems.com techsupport@teledesignsystems.com
More informationINDUSTRIAL OPTO-ISOLATED RS-232 REPEATER
QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485
More informationData Acquisition Modules/ Distributed IO Modules
User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332
More information285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM
285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a result
More informationTD_485 Transceiver Modules Application Guide 2017
TD_485 Transceiver Modules Application Guide 2017 1. RS485 basic knowledge... 2 1.1. RS485 BUS basic Characteristics... 2 1.2. RS485 Transmission Distance... 2 1.3. RS485 bus connection and termination
More informationAtrie WireSpan 600/610 MODEM User's Manual
Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER
More informationUSER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 457B Seven Port Active Twinax Star Hub An ISO-9001 Certified Company Part #07M457B-C Doc. #069011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
More informationUSER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationLCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS
USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product
More informationCL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:
CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0 Americas: +1-800-492-2320 FCC Notice WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
More informationCross-Connect Interface
Cross-Connect Interface User Manual Document #: 050-015-0036R01 November 2006 TASC Systems Inc. Langley, BC Canada Cross-Connect System User Manual Preface This document describes the installation, commissioning
More informationInstruction Manual MX-485-S Bi-directional RS485 Data Transceiver
Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver Copyright 2005, American Fibertek, Inc. 1020JD Table of Contents Functional Description...3 Installation...3 Power Source...3 Power Connection...3
More informationUSER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters An ISO-9001 CertiÞed Company Part# 07M3PMF9 Rev. C Doc# 056020U Revised 1/23/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationEIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA
EIA EIA-232 Information This is one of the most misunderstood areas of RS-232. DTE stands for Data Terminal Equipment, and DCE stands for Data Circuit-terminating Equipment or Data Communications Equipment.
More informationPart Numbers. Fiber Driver - ST/DB25M FIBER DRIVER
January 2010 MD940A-F MD940A-M Part Numbers - ST/DB25F MD940A-F - ST/DB25M MD940A-M FIBER DRIVER CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical
More informationSmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN
SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN 1. SPECIFICATIONS / DIMENSIONS ANALOG OUT Number of Outputs 8 (207) or 4 (107)
More informationA local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.
FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers
More informationEasy-Link Plus Version 2.2
Easy-Link Plus Easy-Link Plus Version 2.2 Copyright 1994-2000 IDA Corporation All Rights Reserved This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
More informationContents. Warranty and Disclaimer 2
Contents Warranty and Disclaimer 2 Physical Dimensions Board Layout 3 Usage Using the PWM board 4 Setting the start address 4 Dimming LED s 5,6 Typical hookup 7 Terminator 8 Troubleshooting Ground, termination,
More informationMULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE
Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE
More informationModem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.
RS-232 to Multimode Optic Modem RS232/RS422/RS485 Fiber Converter to MM optic fibers ELO E14C E17A DIN rail mounting TxD, RxD up to transferring 6km over MM fiber Communication Max. data rate 115.2 protocol
More informationCONV232/422 SERIAL DATA CONVERTER
ACCES I/O PRODUCTS I. 06 Roselle St., San Diego CA 9-06 Tel (88)0-99 FAX (88)0-7 CONV/ SERIAL DATA CONVERTER DATA SHEET Model CONV/ is a bidirectional RS- to RS- converter. It converts full-duplex, single
More informationLBI Installation & Operation
Installation & Operation EDACS Power Monitor Unit ericssonz CONTENTS TABLE OF CONTENTS Page INTRODUCTION... 6 DESCRIPTION... 6 APPLICATION NOTES... 7 VAX SITE CONTROLLER COMPUTER... 7 APPLICATION SOFTWARE
More informationModel RTX-12 Radio Modem
Model RTX-12 Radio Modem Grants Pass, Oregon 154 Hillview Drive Grants Pass, Oregon 97527 (541) 474-6700 Fax: (541) 474-6703 Both the RTX-12A and the RTX-12OEM are normally supplied with full transmit
More informationMODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationRS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<
RS232 RS485/422 RS232 to RS485 or RS422 line converter with isolation >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408
More informationRS-232 Electrical Specifications and a Typical Connection
Maxim > Design Support > Technical Documents > Tutorials > Interface Circuits > APP 723 Keywords: RS-232, rs232, RS-422, rs422, RS-485, rs485, RS-232 port powered, RS-232 to RS-485 conversion, daisy chain,
More informationContents. Warranty and Disclaimer 2 Introduction 3
Contents Warranty and Disclaimer 2 Introduction 3 Physical Dimensions Board Layout 4 Servo connections 5 Using the Serv8 Usage 6 Setting the start address 7 Setting the pulse width 8 Using the configuration
More informationMD-45 AC MD-45 LV/HV INSTALLATION MANUAL
MD-45 AC MD-45 LV/HV INSTALLATI MANUAL 6157-2213 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission CE Approved Converter RS-232 RS-422/485 www.westermo.us
More information+3.3V-Powered, EIA/TIA-562 Dual Transceiver with Receivers Active in Shutdown
19-0198; Rev 0; 10/9 +.Powered, EIA/TIA-5 Dual Transceiver General Description The is a +.powered EIA/TIA-5 transceiver with two transmitters and two receivers. Because it implements the EIA/TIA-5 standard,
More informationRM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01
RM868500D 868MHz 500mW RS232 / RS485 / RS422 Radio Modem Operating Manual English 1.01 Introduction The RM868500D radio modem acts as a wireless serial cable replacement and can wirelessly connect various
More informationMODEL PAXCDC -SERIAL COMMUNICATIONS PLUG-IN OPTION CARDS
Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net Bulletin No. PAXCDC-E Drawing No. LP0402 Released 3/05 MODEL PAXCDC -SERIAL COMMUNICATIONS PLUG-IN OPTION CARDS DESCRIPTION This bulletin serves
More informationLL-105-R LED Dimmer & 0-10V Bridge Setup Guide
www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.
More informationInstallation Instructions. RFID MHz Interface Board for EasyCoder F2 and F4 Printers
Installation Instructions RFID 13.56 MHz Interface Board for EasyCoder F2 and F4 Printers Information in this manual is subject to change without prior notice and does not represent a commitment on the
More informationInterface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).
BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.
More informationTerminus GSM864Q Hardware User Manual
Make Your Communication Boundaries Boundless! Terminus GSM864Q Hardware User Manual Overview The Terminus GSM864Q is a quad band GSM terminal device. From this point on in the document the GSM864Q will
More informationHC900 Remote Termination Panel (RTP) For Analog Inputs
HC900 Remote Termination Panel (RTP) For Analog Inputs Document umber: 515233134 Effective: 7/28/10 Supersedes: 6/8/05 Summary The Remote Termination Panel (RTP) provides an easy way to connect the HC900
More informationCL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice.
CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0 wireless.support@lairdtech.com FCC Notice WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationDigiPoints Volume 1. Student Workbook. Module 2 Modem Overview
Modem Overview Page 2.1 DigiPoints Volume 1 Module 2 Modem Overview Summary One of the potential advantages the cable telecommunications industry has is the ability to carry data signals at speeds significantly
More informationI-2533CS series User Manual
I-2533CS series User Manual Version 1.0.0, Sep. 2013 Service and usage information for I 2533CS / I 2533CS 60 / I 2533CS A / I 2533CS B I-2533CS series CAN to Single Mode Fiber Bridge User Manual (version
More informationMyriad MD9612FP Flash Poll Rack-Mount Modem User s Guide MD9612FP USER S GUIDE XXX Page i REV. A
Myriad MD9612FP Flash Poll Rack-Mount Modem User s Guide 0049-1237-XXX Page i REV. A The products and programs described in this User s Guide are licensed products of Raymar Information Technology, Inc.
More informationThis FAQ covers Single Direction use of current loop with transmitting devices.
PAGE 1 OF 5 This FAQ covers Single Direction use of current loop with transmitting devices. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has
More informationAMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH
AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE OPERATING THIS EQUIPMENT! 116 Willow Road Starkville, MS 39759 USA 662-323-8211 Version 3B Printed in U.S.A.
More informationFEATURES. Static Current (ma) Baud rate (bps) TD321D485H-E 321RHE k TD521D485H-E 521RHE k
Single high-speed RS485 isolated transceiver module (enhanced) RoHS FEATURES Integrated high efficiency isolated DC/DC converter Two- port isolation (3.0k) Operating temperature range: -40 to +85 High
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More information2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL
2070-6A Manual 1 2070-6A Manual Dual 1200 baud Modem For The 2070 Controller GDI 2070-6A MANUAL This Manual covers Modems with the Serial numbers D700000 and up. 2070-6A Manual 2 GDI 2070-6A Manual This
More informationRM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.
RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and
More informationInstallation Guide Metretek RS-485 Adaptor Board
Installation Guide Metretek RS-485 Adaptor Board Document: 900365 Date: February 09, 2006 Revision: A Copyright 2006 Metretek, Inc. All Rights Reserved This publication, or parts thereof, may not be reproduced
More informationRM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.
RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and
More informationRS-422/RS-485 Line Tester Model 485T
Not Recommended for New Installations. Please contact Technical Support for more information. RS-422/RS-485 Line Tester Model 485T Documentation Number 485T1995 This product Designed and Manufactured In
More informationRM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.
RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.09 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationApplication Note: CBLIO-ISO1-xM Cables for the Class 5 D-Style SmartMotor, Revised: 11/9/2016.
Copyright Notice 2016, Moog Inc., Animatics. Application Note: CBLIO-ISO1-xM Cables for the Class 5 D-Style SmartMotor,. This document, as well as the software described in it, is furnished under license
More informationGuardian and DL3282 Modem Interface Technical Service Application Note
Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio
More informationM7 Over-The-Air Protocol. Overview. Technical Brief AN187 Rev A1
Technical Brief AN187 Rev A1 M7 Over-The-Air Protocol By John Sonnenberg Raveon Technologies Corp Overview The M7 GX series of GPS transponders may be directly connected to a Garmin GPS 152H navigation
More informationTDM-1 TRANSPARENT OR ADDRESSABLE RADIO DATA MODEM INSTRUCTION MANUAL
TDM-1 TRANSPARENT OR ADDRESSABLE RADIO DATA MODEM INSTRUCTION MANUAL Features 1200 baud modem for point to point to multi-point communications Simplex or full-duplex operation 63 character flow control
More information