ANALOG AND DIGITAL PHYSICAL INTERFACES
|
|
- Abel Byrd
- 5 years ago
- Views:
Transcription
1 ANALOG AND DIGITAL PHYSICAL INTERFACES Habib Youssef, Ph.D Department of Computer Engineering King Fahd University of Petroleum and Minerals Dhahran, Saudi Arabia COMPUTER NETWORK
2 T h e R S-232/CCITT V.24 and V.28 Interface Computer RS-232/CCITT V.24 Data Data Computer DTE Modem DCE Modem DCE DTE Out of Band Control Out of Band Control DTE : Data Terminal Equipment DCE : Data Circuit Termination Equipment
3 The RS-232/CCITT V.24 and V.28 Interface (Cont.) Data processing (DTE) to modem (DCE) interface The CCITT V.24 Recommendation defines the interchange circuits» V.28 defines the electrical characteristics
4 The RS-232/CCITT V.24 and V.28 Interface (Cont.) In EIA, known as RS-232-C (the third [- C] version of RS-232)» More recent version of RS-232-D (now EIA- 232-D)» Sometimes TIA-232-D (Telecommunications Industry Association)
5 The RS-232/CCITT V.24 and V.28 Interface (Cont.) A 25-pin connector/interface» ISO 2110 is used» Is not part of the RS-232-C standard Bit serial data (full duplex) Out of band control lines
6 The RS-232/CCITT V.24 and thnulmodems V.28 Wi DTE Data Data Req to Send Clear to Send Data Set Ready Signal Detect Data Terminal Ready Null Modem Data Data Req to Send Clear to Send Data Set Ready Signal Detect Data Terminal Ready DCE 7 Signal Ground 7 Note : There are many variations to Null Modem Cross Connection
7 Pin Assignments for V.24/EIA- 232 Shield Tx Data Rx Data Reg to Send Clear to Send DCE Ready GND Carrier Detect Reserved for testing Reserved for testing Unassigned Secn. Recv. Line Signal Detector Secn. CTS Transmitter signal element timing Secondary Tx Data Secondary received data Transmitter signal element timing Secondary RTS Remote Loopback Local DTE Ready Loopback Ring Indicator Data Signal Rate Select Transmit signal element timing Test Mode
8 RS-232/CCITT V.24 & V.28 Related Products It is often convenient to switch RS- 232/V.24 signals from a computer to one of several devices» For example, to different types of printers Simple multiple switches are available for this purpose
9 RS-232/CCITT V.24 & V.28 Related Products (Cont.) Specialized companies have been developed to handle the interface market with products such as» Multiple switches» RS-232/V.24 cables» Null modems» RS-232/V.24 gender changers Breakout boxes to monitor control signals
10 Limitations of RS-232/V.28 An upper data rate of about 20 kbit/s An upper cable length of about 50 to 100 feet (about 20 to 40 m) Some products are available to extend these, but a new approach is needed
11 The Evolution of RS-232-C RS-232-C RS-449 signals RS-422/423 electrical (1977) RS-442 balanced circuits RS-443 unbalanced circuits RS-530 (1987) Balanced Circuits EIA-232-D (1987) Unbalanced circuits V.35 Balanced Circuits
12 Synchronous Transmission Has a known timing relationship between bits and characters Characters are sent one after the other The receiver recovers this timing from transitions in the arriving data 1 0 Start End Characters
13 V.24/EIA-232 dial-up operation
14 Single Ended Interchange Circuit Noise Error Trans Recvr Signal return Note: V.10 is the same as X.26 or RS-423-A (unbalanced)
15 Differential Interchange Circuit Noise Sensitive to differential signal Trans Recvr Noise was rejected Termination resistor Note : V.11 is the same as X.27 or RS-422-A (balanced)
16 CCITT X.21 Interface Physical-level interface between DTE and DCE For synchronous operations on public data networks X.21 uses control transitions and ASCII characters rather than using separate signal lines
17 CCITT X.21 Interface (Cont.) The X.21 electrical characteristics are» CCITT X.27 (balanced; same as V.11 and RS-422)» CCITT X.26 (unbalanced; V.10 and RS- 423) (Note: For operation above 9600 bit/s, X.27 is required) X.21 mechanical characteristics are» 15-pin connector per ISO Standard 4903
18 CCITT X.21 Interface (Cont.) Switched 64 kbit/s X.21 4 DSU Bridge
19 CCITT X.21 Interface (Cont.) Circuit Name Direction To DCE / To DTE G Ground,Common Return Ga DTE Common Return X Gb DCE Common Return X T Transmit X R Receive X C Control X I Indication X S Signal Timing X B Byte Timing (Optional) X
20 CCITT X.21 bis As an interim (perhaps longer term) provision, we have X.21 bis X.21 bis utilizes RS-232 for use with X.25 Particularly used in countries where X.21 has not yet become available
21 CCITT X.21 bis (Cont.) RS-232 signals are used to represent X.21 events» To initiate the call Some X.21 features are not supported» Call progress signals
22 ISDN Interface Terminal Equipment (TE) Network Equipment (NE) Power Source 3 a b c a b c Transmit d d Transmit Receive e e Receive f f Power Sink2 g h g h Power Source 2
NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)
NETWORK INTERFACING TE NT NETWORK NT TE Interface Interface TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment) Interface
More informationKing Fahd University of Petroleum & Minerals Computer Engineering Dept
King Fahd University of Petroleum & Minerals Computer Engineering Dept COE 342 Data and Computer Communications Term 021 Dr. Ashraf S. Hasan Mahmoud Rm 22-144 Ext. 1724 Email: ashraf@ccse.kfupm.edu.sa
More informationConcept of Serial Communication
Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature
More informationElectronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge
Electronics / Water analogy Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Resistor U = R * I 1 Capacitor U 1 i dt C U L di dt Inductance Turbine Flywheel Diode Transistor
More informationDigiPoints Volume 1. Student Workbook. Module 2 Modem Overview
Modem Overview Page 2.1 DigiPoints Volume 1 Module 2 Modem Overview Summary One of the potential advantages the cable telecommunications industry has is the ability to carry data signals at speeds significantly
More informationEIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA
EIA EIA-232 Information This is one of the most misunderstood areas of RS-232. DTE stands for Data Terminal Equipment, and DCE stands for Data Circuit-terminating Equipment or Data Communications Equipment.
More informationAPPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT
ICS ICS ELECTRONICS division of Systems West Inc. AB- APPLICATION BULLETIN SERIAL BACKGROUNDER (Serial 0) INTRODUCTION Serial data communication is the most common means of transmitting data from one point
More informationECE 4510/5530 Microcontroller Applications Week 6 Lab 5
Microcontroller Applications Week 6 Lab 5 Dr. Bradley J. Bazuin Associate Professor Department of Electrical and Computer Engineering College of Engineering and Applied Sciences Lab 5 Element Hardware
More informationChapter 12: Digital Modulation and Modems
Chapter 12: Digital Modulation and Modems MULTIPLE CHOICE 1. FSK stands for: a. Full-Shift Keying c. Full-Signal Keying b. Frequency-Shift Keying d. none of the above 2. PSK stands for: a. Pulse-Signal
More informationLecture #3 RS232 & 485 protocols
SPRING 2015 Integrated Technical Education Cluster At AlAmeeria E-626-A Data Communication and Industrial Networks (DC-IN) Lecture #3 RS232 & 485 protocols Instructor: Dr. Ahmad El-Banna 1 Agenda What
More informationROM/UDF CPU I/O I/O I/O RAM
DATA BUSSES INTRODUCTION The avionics systems on aircraft frequently contain general purpose computer components which perform certain processing functions, then relay this information to other systems.
More informationCHAPTER 5 TRANSMISSION OF DIGITAL DATA INTERFACES & MODEMS
CHAPTER 5 TRANSMISSION OF DIGITAL DATA INTERFACES & MODEMS Information generated by a source need to be encoded into a suitable format for transmission. To transmit the encoded signals generated by the
More information) ,4)0,%8 $4%$#% ).4%2&!#% &/2 53%2 #,!33%3 05",)# $!4!.%47/2+3 ).4%2&!#%3. )454 Recommendation 8 INTERNATIONAL TELECOMMUNICATION UNION
INTERNATIONAL TELECOMMUNICATION UNION )454 8 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU 05",)# $!4!.%47/2+3 ).4%2&!#%3-5,4)0,%8 $4%$#% ).4%2&!#% &/2 53%2 #,!33%3 )454 Recommendation 8 (Extract from
More informationInterface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).
BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.
More informationINTERNATIONAL TELECOMMUNICATION UNION
INTERNATIONAL TELECOMMUNICATION UNION )454 8 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU 05",)# $!4!.%47/2+3 ).4%2&!#%3,)34 /& $%&).)4)/.3 &/2 ).4%2#(!.'% #)2#5)43 "%47%%. $!4! 4%2-).!, %15)0-%.4 $4%!.$
More informationMiniature Synchronous Multipoint Modems
ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours
More informationFanuc Serial (RS232) Communications Information
Memex Automation Inc. 777 Walkers Line, Burlington, Ontario Canada L7N 2G1 Fanuc Serial (RS232) Communications Information Contents Signal Description Fanuc Serial Cable Information Timing Chart When The
More informationSummary of Well Known Interface Standards
Summary of Well Known Interface Standards Forward Designing an interface between systems is not a simple or straight-forward task. s that must be taken into account include: data rate, data format, cable
More informationSerial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo
Serial Input/Output Lecturer: Sri Parameswaran Notes by: Annie Guo 1 Serial communication Concepts Standards USART in AVR Lecture overview 2 Why Serial I/O? Problems with Parallel I/O: Needs a wire for
More informationINTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION OVER THE TELEPHONE NETWORK
INTERNATIONAL TELECOMMUNICATION UNION ITU-T V.24 TELECOMMUNICATION (03/93) STANDARDIZATION SECTOR OF ITU DATA COMMUNICATION OVER THE TELEPHONE NETWORK LIST OF DEFINITIONS FOR INTERCHANGE CIRCUITS BETWEEN
More informationLocal Asynchronous Communication. By S.Senthilmurugan Asst.Professor/ICE SRM University. Chennai.
Local Asynchronous Communication By S.Senthilmurugan Asst.Professor/ICE SRM University. Chennai. Bitwise Data Transmission Data transmission requires: Encoding bits as energy Transmitting energy through
More informationPRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections
-01-1/ 00 by B&B Electronics. All rights reserved. Model Port-Powered RS- Fiber Optic Modem with Handshake Support Description The allows any two pieces of RS- asynchronous serial equipment to communicate
More informationChapter 9: Serial Communication Interface SCI. The HCS12 Microcontroller. Han-Way Huang. September 2009
Chapter 9: Serial Communication Interface SCI The HCS12 Microcontroller Han-Way Huang Minnesota State t University, it Mankato September 2009 H. Huang Transparency No.9-1 Why Serial Communication? Parallel
More informationUSER'S MANUAL. Model : K
USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include
More informationUnbounded Transmission Media
Unbounded Transmission Media Unbounded Media The three main types of wireless media are Radio Microwave infrared Electromagnetic spectrum for wireless communication Unguided waves can travel from source
More informationRS-422/RS-485 Line Tester Model 485T
Not Recommended for New Installations. Please contact Technical Support for more information. RS-422/RS-485 Line Tester Model 485T Documentation Number 485T1995 This product Designed and Manufactured In
More informationThere are many important factors when trying to achieve good, reliable communications between 2 devices.
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationAPPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC)
Solved by APPLICATION NOTE ANI6 TM Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC) INTRODUCTION The Sipex SP504 is a cost-effective,
More informationKiloStream Data Sheet
KiloStream Data Sheet KiloStream speeds The choice of interfaces and speeds shown below enable a wide variety of equipment conforming to CCITT* standards to be connected. Speeds and interfaces Speed kbit/s
More informationPART 4 DIGITAL METHODS. Chapter 13 Digital Fundamentals. Parallel Data Transfer. Fig Parallel data handshaking
PART 4 DIGITAL METHODS Chapter 13 Digital Fundamentals The remainder of this book will deal with digital methods in modern communications. We will build on the introduction to digital data in Chapter 3,
More informationEECE494: Computer Bus and SoC Interfacing. Serial Communication: RS-232. Dr. Charles Kim Electrical and Computer Engineering Howard University
EECE494: Computer Bus and SoC Interfacing Serial Communication: RS-232 Dr. Charles Kim Electrical and Computer Engineering Howard University Spring 2014 1 Many types of wires/pins in the communication
More informationSIN 57 Issue 2.4 May 2018
SIN 57 Issue 2.4 May 2018 Suppliers' Information Note For The BT Network BT KiloStream X.21 Interface Service Description Each SIN is the copyright of British Telecommunications plc. Reproduction of the
More informationBASIC PARAMETERS FOR THE MEASUREMENT OF ERROR PERFORMANCE AT BIT RATES BELOW THE PRIMARY RATE
INTERNATIONAL TELECOMMUNICATION UNION CCITT O.153 THE INTERNATIONAL TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE (11/1988) SERIES O: SPECIFICATIONS FOR MEASURING EQUIPMENT Equipment for the measurement
More informationINTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES
INTERNATIONAL TELECOMMUNICATION UNION CCITT X.21 THE INTERNATIONAL (09/92) TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE DATA COMMUNICATION NETWORK: INTERFACES INTERFACE BETWEEN DATA TERMINAL EQUIPMENT
More informationAccess to Data & Computer Networks Physical Level
Lecture 7 Access to Data & Computer Physical Level Terminology Serial Interface Cable Modems DSL technologies 1 ISP (Internet Service Provider) - An Internet service provider company that provides other
More informationMGE TM Galaxy TM , 60 Hz kva
Home Alarms Online Trend Statistics Rectifier Battery Inverter Bypass AC Bypass Output Set up Normal AC Q4S Load protected QBP QF 0 Hour 50 Min. 5 kva 00% 0% 00% 0 50% Load equipment 0 80% 50% Remote vision
More informationTCSS 372 Laboratory Project 2 RS 232 Serial I/O Interface
11/20/06 TCSS 372 Laboratory Project 2 RS 232 Serial I/O Interface BACKGROUND In the early 1960s, a standards committee, known as the Electronic Industries Association (EIA), developed a common serial
More information) #(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!. KBITS 53).' K(Z '2/50 "!.$ #)2#5)43
INTERNATIONAL TELECOMMUNICATION UNION )454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU $!4! #/--5.)#!4)/. /6%2 4(% 4%,%(/.%.%47/2+ 39.#(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!.
More informationTECHNICAL TBR 2 BASIS for January 1997 REGULATION
TECHNICAL TBR 2 BASIS for January 1997 REGULATION Source: ETSI TC-TE Reference: DTBR/TE-005002 ICS: 33.020, 33.040.40 Key words: PDN, testing, type approval, X.25 Attachment requirements for Data Terminal
More informationThis Special Provision covers the requirements for the installation and testing of fibre optic modems (FOM).
FIBRE OPTIC MODEMS - Item No. Special Provision No. 683S09 September 2007 1. SCOPE This Special Provision covers the requirements for the installation and testing of fibre optic modems (FOM). 2. REFERENCES
More informationSerial Communications RS232, RS485, RS422
Technical Brief AN236 Technical Brief AN236Rev A Serial Communications RS232, RS485, RS422 By John Sonnenberg S u m m a r y Electronic communications is all about interlinking circuits (processors or other
More informationZCS485 User s Manual. Version ZYPEX, Inc.
ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter
More informationTTC INTERCEPTO R 147. Artisan Technology Group - Quality Instrumentation... Guaranteed (888) 88-SOURCE
TTC INTERCEPTO R 147 Installing and maintaining 2M and data circuits in the field requires the right tools. The INTERCEPTOR 147 Communications Analyser was specifically designed to meet this challenge
More informationM9606. FSK Modem. 5C Communications Inc.
FSK Modem Application modem is a voice-frequency telegraphy unit (VFT unit) which operates according to the principle of binary frequency shift keying. It is designed especially for Power Industrial applications.
More informationSuperseded by a more recent version INTERNATIONAL TELECOMMUNICATION UNION
INTERNATIONAL TELECOMMUNICATION UNION ITU-T V.24 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/96) SERIES V: DATA COMMUNICATION OVER THE TELEPHONE NETWORK Interfaces and voiceband modems List of
More information2 Mbit/s and Data Analyzer. Reference Manual
50-13139-01 Rev. B TM 2 Mbit/s and Data Analyzer Reference Manual APRIL 1995 1992 Telecommunications Techniques Corporation 20400 Observation Drive, Germantown, Maryland 20876 (800) 638-2049 or (301) 353-1550
More informationRS-232 / 20mA Interface Converter ELO E00Q. Operation manual
RS-232 / 20mA Interface Converter ELO E00Q Operation manual 2 ELOE00QZKE001 1.0 Introduction 4 1.1 Use of the converter 4 2.0 Operation principles 4 3.0 Installation 4 3.1 Converter connection to RS-232
More informationOnline Signature Verification by Using FPGA
Online Signature Verification by Using FPGA D.Sandeep Assistant Professor, Department of ECE, Vignan Institute of Technology & Science, Telangana, India. ABSTRACT: The main aim of this project is used
More informationPERIPHERAL INTERFACING Rev. 1.0
PERIPHERAL INTERFACING Rev.. This work is licensed under the Creative Commons Attribution-NonCommercial-Share Alike 2.5 India License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/in/deed.en
More informationMulti-Channel RS-232 Serial RF Transceiver
RF-232 Multi-Channel RS-232 Serial RF Transceiver The RF-232 subassembly is a multi-channel serial radio transceiver. This device accepts and outputs standard serial data at one of three selectable data
More informationE205 Long Range Wireless Modem V1.0 Data Sheet
E205 Long Range Wireless Modem V1.0 Data Sheet The Long Range Wireless Modem E205 is a radio transmitter / receiver designed for transparent wireless data transmission over long distances. It operates
More informationMULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE
Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE
More informationCS601 Data Communication Solved Objective For Midterm Exam Preparation
CS601 Data Communication Solved Objective For Midterm Exam Preparation Question No: 1 Effective network mean that the network has fast delivery, timeliness and high bandwidth duplex transmission accurate
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem
MA- AC MA- DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galavanic Isolation Transient Protection 0-00 Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem
More informationA50/A51/A60. June 2008 (4th Edition) All Rights Reserved
A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection
More informationUSING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)
ICS DataCom Application Note USING RS- to RS- CONVERTERS (With RS-, RS- and RS- devices) INTRODUCTION Table RS-/RS- Logic Levels This application note provides information about using ICSDataCom's RS-
More informationInstallation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE
Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation
More information+3.3V Multiprotocol 3Tx/3Rx Software-Selectable Control Transceivers
19-173; Rev 1; 8/1 +3.3V Multiprotocol 3Tx/3Rx General Description The are three-driver/three-receiver multiprotocol transceivers that operate from a single +3.3V supply. The, along with the MAX317 and
More informationCP485-4 User s Manual
CP485x4 User s Manual Version 1.0 2005 ZYPEX, Inc. CP485-4 User s Manual Table of Contents Table of Contents Product Description 1 CP485x4 Configuration & Setup 2 Power 2 Baud Rate 2 Control Mode 2 Duplex
More information+3.3V, Multiprotocol, 3 Tx/3 Rx, Software- Selectable Clock/Data Transceiver
19-333; Rev ; 4/ +3.3V, Multiprotocol, 3 Tx/3 Rx, Software- General Description The is a three-driver/three-receiver multiprotocol transceiver that operates from a +3.3V single supply. The, along with
More informationCS601-Data Communication Latest Solved Mcqs from Midterm Papers
CS601-Data Communication Latest Solved Mcqs from Midterm Papers May 07,2011 Lectures 1-22 Moaaz Siddiq Latest Mcqs MIDTERM EXAMINATION Spring 2010 Question No: 1 ( Marks: 1 ) - Please choose one Effective
More informationModem 1200 baud 500FSD10 EDS500 series - FSK modems
Manual Modem 1200 baud 500FSD10 EDS500 series - FSK modems Application, characteristics and technical data have to be taken from the hardware data sheet: 500FSD10 Data sheet 1KGT150982 Operation The 500FSD10
More informationThis is by far the most ideal method, but poses some logistical problems:
NXU to Help Migrate to New Radio System Purpose This Application Note will describe a method at which NXU Network extension Units can aid in the migration from a legacy radio system to a new, or different
More informationITL Basics of Encoding and Wiring
ITL Basics of Encoding and Wiring Objectives Quick overview of wide-area communications Define the term Structured Wiring Define "analog" and "digital" data. List the common methods used to encode analog/digital
More informationUNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter
User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741
More informationHR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11
HR1200 Version 1.00 ATIM RADIOCOMMUNICATION 1/11 Contact Information ATIM RADIOCOMMUNICATION Les guillets 38250 Villard de Lans France Tel : +33 (0)4 76 95 50 65 Fax: +33 (0)4 76 95 50 64 Web : www.atim.com
More informationThis FAQ covers Single Direction use of current loop with transmitting devices.
PAGE 1 OF 5 This FAQ covers Single Direction use of current loop with transmitting devices. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has
More informationEUROPEAN pr ETS TELECOMMUNICATION February 1996 STANDARD
FINAL DRAFT EUROPEAN pr ETS 300 118 TELECOMMUNICATION February 1996 STANDARD Second Edition Source: ETSI TC-TE Reference: RE/TE-05049 ICS: 33.020 Key words: PSTN, modems Public Switched Telephone Network
More informationTRXQ1 RXQ1 FM NARROW BAND TRANSCEIVERS. RXQ1 Version. Applications. TRXQ1 Version
RF Transceiver or Intelligent Modem Versions Host Data Rate upto 19,200 Baud Data Rates to 20 K baud. 2 Selectable RF Channels Narrowband Crystal Controlled Optimal Range 200m Supply Voltage 3-5V Very
More information1.0 Introduction. Related Products and Documentation
Quick Start t Guide ER450 Data Radio 1.0 Introduction Welcome to the Quick Start Guide for the ER450 Data Radio. This guide provides step-by-step instructions, with simple explanations to get you up-and-running.
More informationIntermittent Vibration 0.075
FEATURES DESCRIPTION PLC-COM-CM1 Series Multi Drop Configuration of up to 32 Units Baud Rates Range from 300 to 38,400 bps 1:1/1:N/N:M (RS-422) Communication is Supported Full-Duplex (RS-422) and Half-Duplex
More informationInterface converter G kbit/sec
converter User s Guide 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 Interface converter G.703.1 64 kbit/sec Features Maximum line attenuation
More informationADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.
User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS
More informationOPERATION MANUAL INSTALLATION AND KHS.1. 2-Channel High-Speed Data Module. Kilomux I/O Module. The Access Company
INSTALLATION AND OPERATION MANUAL KHS.1 2-Channel High-Speed Data Module Kilomux I/O Module The Access Company KHS.1 2-Channel High-Speed Data Module Installation and Operation Manual Notice This manual
More informationDSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.
DSP4xxFP SA USER S MANUAL A01561 Rev. A This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA700425 and up. DSP4xxSA User s Manual A01561 Rev. X Proprietary Data This document
More informationThis FAQ covers the common questions from technicians installing these converters.
PAGE 1 OF 6 This FAQ covers the common questions from technicians installing these converters. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has
More informationThis manual may be copied in any form including electronic. It may not be modified in any way without the express permission of CTC Union
USER S GUIDE This manual may be copied in any form including electronic. It may not be modified in any way without the express permission of CTC Union Technologies Co. Ltd. Description G703/64A I/F Converter
More informationTDM-1 TRANSPARENT OR ADDRESSABLE RADIO DATA MODEM INSTRUCTION MANUAL
TDM-1 TRANSPARENT OR ADDRESSABLE RADIO DATA MODEM INSTRUCTION MANUAL Features 1200 baud modem for point to point to multi-point communications Simplex or full-duplex operation 63 character flow control
More informationSMARTALPHA RF TRANSCEIVER
SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design
More informationAtrie WireSpan 600/610 MODEM User's Manual
Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER
More informationNMEA Protocol Converter 2 Plus 3 Users Guide
NMEA Protocol Converter 2 Plus 3 Constellation Data Systems, Inc. 10296 Springfield Pike Cincinnati, OH 45215 Phone: (513) 984-4491 Fax: (513) 984-4896 Web: www.constellationdata.com Copyright 2006 Constellation
More informationWTDIN-M. eeder. Digital Input Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies
eeder Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Digital Input Module FEATURES 8 wide-range digital input channels with high voltage transient protection.
More informationUniversal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485
4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel
More informationWTDOT-M. eeder. Digital Output Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies
eeder Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Digital Output Module FEATURES 8 high-current open-collector output channels with automatic overload shutdown.
More informationPart Numbers. Fiber Driver - ST/DB25M FIBER DRIVER
January 2010 MD940A-F MD940A-M Part Numbers - ST/DB25F MD940A-F - ST/DB25M MD940A-M FIBER DRIVER CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical
More information)454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU
INTERNATIAL TELECOMMUNICATI UNI )454 6 TELECOMMUNICATI STANDARDIZATI SECTOR OF ITU $!4! #/--5.)#!4)/. /6% 4(% 4%,%0(/.%.%47/+,//0 4%34 $%6)#%3 &/ -/$%-3 )454 Recommendation 6 (Extract from the "LUE "OOK)
More informationVC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules
4, 8 or 16 analog voice channels using 64 kbps toll-quality PCM encoding; 24/32 kbps ADPCM encoding option for 4- and 8-channel modules E&M, FXS or FXO interface options Caller ID A-law or μ-law companding
More informationCONV232/422 SERIAL DATA CONVERTER
ACCES I/O PRODUCTS I. 06 Roselle St., San Diego CA 9-06 Tel (88)0-99 FAX (88)0-7 CONV/ SERIAL DATA CONVERTER DATA SHEET Model CONV/ is a bidirectional RS- to RS- converter. It converts full-duplex, single
More informationUsing the TB8100 Base Station as a Talk-Through, Community, or Linked Repeater
Using the TB8100 Base Station as a Talk-Through, Community, or Linked Repeater Application Note TN-743 1 June 2003 Tait Electronics Ltd Page 1 of 8 558 Wairakei Rd, P.O. Box 1645, Christchurch, New Zealand
More informationModel RTX-12 Radio Modem
Model RTX-12 Radio Modem Grants Pass, Oregon 154 Hillview Drive Grants Pass, Oregon 97527 (541) 474-6700 Fax: (541) 474-6703 Both the RTX-12A and the RTX-12OEM are normally supplied with full transmit
More informationAppendix C RS-485 Network
Appendix C RS-485 Network EIA RS-485 is the industry s most widely used bidirectional, balanced transmission line standard. It is specifically developed for industrial multi-drop systems that should be
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem
INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 0-00 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem Short Haul Modem
More informationINSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG
MD- AC MD-DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galavanic Isolation -00 Transient Protection CE Approved Westermo Teleindustri AB REV. A Strömslingeomvandlare Current loop converter
More informationAccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1
INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,
More informationData Communication and Media
Data Communication and Media Concept and Model of Communications Analogy Signal and Digital Signal Signal Frequency, Spectrum and Bandwidth System Frequency Response and Bandwidth Transmission Media and
More informationBasic Communications Theory Chapter 2
TEMPEST Engineering and Hardware Design Dr. Bruce C. Gabrielson, NCE 1998 Basic Communications Theory Chapter 2 Communicating Information Communications occurs when information is transmitted or sent between
More informationA RF53 Data modem. User Guide
A RF53 Data modem User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject to change without
More informationUSER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationGPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.
GPNP Inc. NT384 NT1 User Manual Revision 1.00 17/6/2002 Information in this guide is subject to change without notification. Copyright 2002 GPNP Inc. U.S.A. IMPORTANT SAFETY INSTRUCTIONS When using your
More informationEXPERIMENT NO:-1. OBJECTIVE: To study Basics of serial communication ports and protocols.
EXPERIMENT NO:-1 OBJECTIVE: To study Basics of serial communication ports and protocols. EQUIPMENTS: DCT-03 Kit 9 Pin D connector Cables 2 Nos. Computers 2 nos. Connecting Chords. Power Supply. THEORY:
More information