Typical Efficiency (1) 24 Vdc 90 ~ 305 Vac 0~4.00 A 96 W 87% EUV-096S024SV. 36 Vdc 90 ~ 305 Vac 0~2.66 A 96 W 88%

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Typical Efficiency (1) 24 Vdc 90 ~ 305 Vac 0~4.00 A 96 W 87% EUV-096S024SV. 36 Vdc 90 ~ 305 Vac 0~2.66 A 96 W 88%"

Transcription

1 EUV096SxxxSV Features Ultra High Efficiency (Up to 90%) High Power Factor (0.99 Typical) Constant Voltage Lightning Protection AllRound Protection: OVP, OCP, SCP, OTP Waterproof (IP67) SELV 5 Years Warranty Description The EUV096SxxxSV series is a 96W, constantvoltage IP67 LED driver that operates from Vac input with excellent power factor. It is created for many lighting applications including architectural, decorative and signage. The high efficiency of the driver and compact metal case enables them to run cooler, significantly improving reliability and extending product life. To ensure troublefree operation, protection is provided against input surge, over current, output over voltage, short circuit, and over temperature. Models Voltage Input Voltage Range Current Range Max. Power Typical Efficiency (1) Power Factor 120Vac 220Vac Model Number (2) 24 Vdc 90 ~ 305 Vac 0~4.00 A 96 W 87% EUV096S024SV 36 Vdc 90 ~ 305 Vac 0~2.66 A 96 W 88% EUV096S036SV 48 Vdc 90 ~ 305 Vac 0~2.00 A 96 W 88% EUV096S048SV 54 Vdc 90 ~ 305 Vac 0~1.77 A 96 W 90% EUV096S054SV Note: (1) Measured at 25C, 100% load and 220 Vac input. (2) SELV Input Specifications Input Voltage 90 V 305 V Input Frequency 47 Hz 63 Hz Leakage Current 1 ma At 277Vac 60Hz input Input AC Current 1.2 A Measured at 100% load and 100 Vac input. 0.6 A Measured at 100% load and 220 Vac input. Inrush Current 69 A Inrush Current(I 2 t) 2.8 A 2 s At 220Vac input, 25 Cold start, Duration= 2 ms, 10%Ipk10%Ipk Tel: Fax:

2 EUV096SxxxSV Input Specifications (Continued) PF 0.90 THD 20% At Vac, 5060Hz, 75%100%load Specifications Voltage Tolerance 5% 5% Ripple and Noise (pkpk) 3% V O Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uf ceramic capacitor and a 10 uf electrolytic capacitor. Line Regulation ±1% Load Regulation ±2% Turnon Delay Time 1.0 s 2.0 s Measured at 120Vac input, 75%100%load 1.0 s 2.0 s Measured at 220Vac input, 75%100%load Overshoot / Undershoot Load Dynamic Response Deviation 10% When power on or off. 5% V O Settling Time 10 ms R/S: 1 A/uS Load: 25% ~ 75% full load. Temperature coefficient 0.03%/C Case temperature = 0C ~Tc max Note: All specifications are typical at 25 C unless otherwise stated. Protection Functions Over Voltage Protection V O = 24 V V O = 36 V V O = 48 V V O = 54 V 30 V 45 V 55 V 65 V 35 V 50 V 60 V 75 V Over Current Protection 100% I O 110% I O Hiccup mode. The power supply shall be selfrecovery when the fault condition is removed. Over Temperature ProtectionTc Short Circuit Protection Maximum temperature of the case. The power supply 110 C shall be selfrecovery when the fault condition is removed. No damage shall occur when any output operating in a short circuit condition. The power supply shall be selfrecovery when the fault condition is removed. Tel: Fax:

3 EUV096SxxxSV General Specifications Efficiency Efficiency V O = 24 V V O = 36 V V O = 48 V V O = 54 V V O = 24 V V O = 36 V V O = 48 V V O = 54 V 83% 84% 84% 85% 85% 88% MTBF Lifetime Operating Case Temperature for Safety Tc_s Operating Case Temperature for Warranty Tc_w 40 C 85% 87% 87% 88% 88% 90% 202,000 Hours 56,600 Hours 89C Measured at 100% load, 120 Vac input, 25 ambient temperature, after the unit is thermally stabilized. It will be about 2.5% lower, if measured immediately after startup. Measured at 100% load, 220 Vac input, 25 ambient temperature, after the unit is thermally stabilized. It will be about 2.5% lower, if measured immediately after startup. Measured at 120Vac input,80% Load and 25C ambient temperature (MILHDBK217F) Measured at 120Vac input, 80%load; Case Tc point. See the lifetime vs. Tc curve for the details 40 C +70 Case temperature for 5 years warranty Storage Temperature 40 C +85 Humidity: 5% RH to 100% RH Dimensions Inches (L W H) Millimeters (L W H) With mounting ear Net Weight 925 g Note: All specifications are typical at 25 C unless otherwise stated. Safety & EMC Compliance Safety Category Standard CE EN , EN CCC GB , GB PSE2 J , J EMI Standards EN 55015/GB EN /GB EN J EMS Standards EN EN Notes Conducted emission Test &Radiated emission Test Harmonic current emissions Voltage fluctuations & flicker Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Notes Electrostatic Discharge (ESD): 15 kv air discharge, 8 kv contact discharge RadioFrequency Electromagnetic Field Susceptibility TestRS Tel: Fax:

4 EUV096SxxxSV Safety & EMC Compliance (Continued) EMS Standards Notes EN EN EN EN EN EN Electrical Fast Transient / BurstEFT Surge Immunity Test: AC Power Line: line to line 4 kv, line to earth 6 kv Conducted Radio Frequency Disturbances TestCS Power Frequency Magnetic Field Test Voltage Dips Electromagnetic Immunity Requirements Applies To Lighting Equipment Derating Curve Lifetime vs. Case Temperature Curve Tel: Fax:

5 EUV096SxxxSV Mechanical Outline INPUT (VDE H05RNF 3*1.0mm 2 7.2) OUTPUT (VDE H05RNF 2*1.0mm 2 6.8) AC/L(BROWN) AC/N(BLUE) GND/(YELLOW/GREEN) V+(BROWN) V (BLUE) Tc PROJ: Unspecified tolerance:±1 RoHS Compliance Our products comply with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. Tel: Fax:

6 EUV096SxxxSV Revision History Change Date Rev. Description of Change Item From To Change PF at 220Vac Change the notes for models / / Change Ripple and Noise (pkpk) 2% Vo 3% Vo A B Delete Derating Curve / / Add Max. Case Temperature / tc: 89 Update safety standards / / Add FCC Part15 Class B / Update mechanical Outline / / FCC Part 15 Class B, ANSI C63.4:2009. ModelsTE 88%,89%,89%,90% 87%,88%,88%,90% Input SpecificationsInput AC Current 1.2A 1.3A Inrush Current 50A 69A Specifications Turnon Delay Time Protection Functions / General SpecificationsTyp. 0.8S 1S 1S 3S 0.8S 1S 0.8S 2S 87% 87& 87% 87% 88% 88% 88% 87% 89% 88& 89% 88% 90% 90% General SpecificationsNotes 1% 23% C Input AC Current 1.3 A 1.2 A D All ModelsMin Efficiency / 1% Lower E F G Derating Curve / Updated Life time vs. Tc Curve / Added Max Case Temperature / Updated EN line to line 2 kv, line to earth 4 kv SELV / Added Duration of Inrush Current 140 μs 2 ms Operating Curve Temperature/Derating / Updated MTBF & Life time Typical / Added line to line 4 kv, line to earth 6 kv H Life time Curve / Updated Min PF, Max THD, Temperature Coefficient I Turnon delay time / Added 1s 3s 1s 2s 0.8s 2s 1s 2s Tel: Fax:

7 EUV096SxxxSV Revision History Change Date Rev. Description of Change Item From To J CQC CCC Updated PSE / Added Features 5 Years Warranty Added Description / Updated Models / Updated Input Specifications PF/THD Updated Specifications Turnon Delay Time Updated Temperature coefficient Max 0.03%/ Typ 0.03%/ General Specifications General Specifications Operating Case Temperature Updated for Safety Tc_s Operating Case Temperature Updated for Warranty Tc_w General Specifications Storage Temperature Updated Environmental Specifications / Deleted Dimensions With mounting ear Added Net Weight 850g 925g Safety & EMC Compliance / Updated Max. Case Temperature / Deleted Lifetime vs. Case Temperature Curve / Updated Mechanical Outline / Updated Tel: Fax: